Atch 8 - BLDG 2.pdf
PDF 9 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
- Solicitation number
- 36C77622B0035
About this file
This federal solicitation seeks construction services for infrastructure upgrades at the St. Cloud Veterans Affairs Health Care System. Work includes electrical, bonding, UPS, building management system interfaces, access security, HVAC assessments, renovations, data center/server room upgrades, fiber infrastructure installation between buildings, and hazardous materials abatement. The contractor shall furnish all labor, materials, tools and equipment to complete upgrades in accordance with specifications and contract drawings. The Department of Veterans Affairs Technology Acquisition Center in Austin is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 50
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING FIBER - INSIDE
VFY EXIST
EXISTING FIBER - OUTSIDE
VFY EXIST
FIBER ROUTE - INSIDE
SEE TELECOM
FIBER ROUTE - OUTSIDE
SEE CIVIL
BUILDING OUTLINE
VFY EXIST
CORRIDOR OUTLINE
VFY EXIST
LEGEND
TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST
44TH AVE.
TRAIL 1
TRAIL 2
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2)
15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
GRAVEL
GRAVEL
GRAVEL
EXISTING
ROAD
CHAIN LINK FENCE
CHAIN LINK FENCE
16' GATE
GRAVEL
ELECTRICAL
SUBSTATION
G E N E R A T O R
FUEL LINES
CONDU ITS TO TU NNEL
M V
D U
C T
B A
N K
1 1 2 W
PHARMACY ADDITION
11 2 E
G E N E R A T O R
B
CORRIDOR LINK
A
C T
TR
A
IL
ER
174 s .f.
256 s .f.
185 s .f.
149 s ..f.
155 s .f.
104 s .f.
70 s. .f .
72 s .f.
110 s .f.
276 s .f.
112 s .f.
99 s .f.
57 s .f.
146 s .f.
434 s .f.
R A
MP
U P
1:
M A X
R A
MP
U P
1:
M A X
RA
M P
UP
1:2 0 M
AX
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2) 15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
.3
TRANSFORMER
BUILD ING
#91
5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN
O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW
C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D
P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S
R EC O M M EN D ATIO N S
N EW G AS SU P P LY M AIN
IN TO B U ILD IN G
SP AR E
P H O N E LIN E
EXTEN D S TO
E XISTIN G
P H O N E IN
B O ILER R O O M
P ER P LAN .
SP AR E
P H O N E
LIN E TO
M ETER
TU N N EL
E XTEN D S
A D D ITIO N AL
2'- 0" U N D ER
B U ILD IN G
FUEL LINE
VENT LINE
1,000 GAL.
UNDERGROUND
DIESEL FUEL
TANK
1,000/5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
S 1
LIG H T
N EW G AS SU P P LY
(C O O R D IN ATE W ITH SU P P LIER )
12"D
10"D
"D
TP TP
EXIST. BUILDING
EXIST.
BUS STOP
CC
L O
O P
16"
20"
12"
3"
8"
DN
0.
0’
BIRDCAGE
B
IR
D C
A G
E
NSP ELECTRICAL
FOR HWY DEPT
T101
I.T.
CHILLER
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
VESTIBULE
DN
DN
DN
FD
DN
F B
F
B
F B
F
B
F B
F
B
SOUTH
VESTIBULE
PASS
THROUGH
LINK TO
BUILDI NG 51
6 3. 32 56
1 13 5. 35 78
PARKING
NO
PARKING
93 49
37 6
109 5
1A
S M
O K
E B
L D
G
SMOKE
BLDG
SMOKE
BLDG
S M
O K
E B
L D
G
SMOKE
BLDG
M.H.
STOR.
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
STOR.
BIO-
HAZ.
SAUK RIVER
GP
HOLDING POND
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
OWNER AND
CONSULTANTS:
CONTACT:
ADDRESS:
MIKE ENGMARK
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
NAME:
ADDRESS:
CONTACT:
ADVANCED STRUCTURAL TECHNOLOGIES
7301 OHMS LANE; SUITE 215
EDINA, MN 55439
ZACHARY CRAIG
PHONE:
NAME:
ADDRESS:
CONTACT:
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
PHONE: 402-991-5520
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
IAN WEBER
763-412-4000
ARCHITECT:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
EDWARD MARKFORT
763-412-4000
952-854-9302
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
402-991-5520
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
COVER
DATE:
APPROVED: APPROVED: PROJECTS SECTION MANAGER
APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:
APPROVED: SAFETY MANAGER
APPROVED: CHIEF OF POLICE
APPROVED: PATIENT SAFETY
DATE:
DATE:
DATE: APPROVED: EMS MANAGER
APPROVED: M/O MANAGER
DATE:
DATE:
DATE:DATE:
APPROVED: MEDICAL CENTER DIRECTOR
APPROVED: PROJECT COR DATE:
APPROVED: INFECTION CONTROL NURSE DATE:
APPROVED: SERVICE LINE DIRECTOR
APPROVED: GEMS COORDINATOR DATE:
DATE:
APPROVED: NURSE EXECUTIVE
APPROVED: CHIEF OF STAFF DATE:
APPROVED: DIRECTOR FMS
APPROVED: ASSOCIATE DIRECTOR
DATE:
DATE:
DATE:
DATE:APPROVED: DATE:
APPROVED: DATE:
APPROVED: DATE:
Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System
N
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
VICINITY MAP:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHONE: 320-252-1670
CIVIL ENGINEER:
VA COR:
TELECOMMUNICATIONS ENGINEER:
CONTACT:
ADDRESS:
JONATHAN WEST
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
PHONE: 504-250-2699
PROGRAM MANAGER:
EMAIL: Jonathan.West@vciint.com
STRUCTURAL ENGINEER:
MECH/ELEC/PLUMB/FIRE ENGINEER:
C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -2
-R E
M a rk fo rt
.r v t
/2
/2
:2 :2
A
M
2-GI000
BUILDING 2 COVER SHEET &
SHEET INDEX
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
BUILDING 2 - EHRM INFRASTRUCTURE UPGRADES
03/30/2022
0APPROX 150' 300'75'
SHEET INDEX - BUILDING 2
SHEET NO. SHEET TITLE
2-GI000 BUILDING 2 COVER SHEET & SHEET INDEX
2-GI101 BASEMENT FLOOR INFECTION CONTROL & PHASING PLAN
2-HA-1A REFERENCE - BASEMENT FLOOR - ASBESTOS RE-SURVEY
2-HA-2A REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY
2-HA-3A REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY
2-AS100 BASEMENT PLANS
2-AS110 FIRST FLOOR - OVERALL PLAN
2-AS120 SECOND FLOOR - OVERALL PLAN
2-TD100 BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
2-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION
2-TD120 SECOND FLOOR PLAN - TELECOM - DEMOLITION
2-TD130 THIRD FLOOR PLAN - TELECOM - DEMOLITION
2-TN100 BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
2-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS
2-TN120 SECOND FLOOR PLAN - TELECOMMUNICATIONS
2-TN130 THIRD FLOOR PLAN - TELECOMMUNICATIONS
2-TN200 BASEMENT FLOOR PLAN - TELECOM - CABLE DISTANCE
2-TN300 ENLARGED PLAN - TELECOMMUNICATIONS - DEMO
2-TN400 ENLARGED PLANS - TELECOMMUNICATIONS
02-E200 BASEMENT FLOOR PLAN - ELECTRICAL
02-E201 FIRST FLOOR PLAN - ELECTRICAL
02-E300 ELECTRICAL ENLARGED PLANS
02-E400 ELECTRICAL DIAGRAMS
02-E500 ELECTRICAL SCHEDULES
02-M100 BASEMENT AND FIRST FLOOR DEMOLITION - MECHANICAL
02-M200 BASEMENT FLOOR REMODEL - MECHANICAL
02-M201 FIRST FLOOR REMODEL- MECHANICAL
SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION
ROOM SCHEDULE
NO. NAME C
A
B
LI
N G
P A
T C
H P
A N
E L
F
IB
E R
P O
W E
R
B O
N D
IN
G
U P
S
D E
D
IC
A T
E D
C O
O
LI
N G
T E
M P
E R
A T
U R
E
H U
M
ID
IT
Y
R A
C K
S E
N S
O R
S P
A C
E
AREA
WIDTH
(FT)
LENGTH
(FT) REMARKS
BASEMENT
001A TELECOM ROOM X X X X X X X 64 SF 5.4 11.8 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM
ROOM STANDARDS. SEE TELECOM DRAWINGS
OPENING SCHEDULE
VA Building Number
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
HAZARDOUS MATERIAL SCHEDULE
LEVEL ROOM NO. ROOM NAME QUESTIONABLE HAZARDOUS ELEMENT POSSIBLE ABATEMENT ACTION
BASEMENT 001A TELECOM ROOM NONE. SEE 2-HA-1A NONE. ACM TO REMAIN UNDISTURBED
HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT
DISTURB QUESTIONABLE HAZARDOUS MATERIAL.
LEAK PREVENTION / DIVERTER SCHEDULE
LEVEL
ROOM
NO. ROOM NAME OVERHEAD LEAK DIVERTER AND DRAIN PIPING LEAK PREVENTION BARRIER WATERPROOFING
BASEMENT 001A TELECOM ROOM YES MWP INT: WEST
SEE GENERAL NOTES SHEET FOR DETAIL. MWP = MEMBRANE WATERPROOFING. MASONRY = FLUID-APPLIED WATERPROOFING. INT = INTERIOR. EXT = EXTERIOR
ICRA PHASE CONSTRUCTION ROOM SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
CAI BLDG NAME /
FUNCTION
CONSTRUCTION
PROJECT ACTIVITY
INFECTION CONTROL
RISK GROUP
CONTROL
PROCEDURE CLASS SECTION
CONSTRUCTION ZONE /
OCCUPIED CONSTR
DAY /
NIGHT
BASEMENT 001A TELECOM ROOM DOMICILIARY TYPE B GROUP 1 CLASS II EAST OCCUPIED CONSTRUCTION DAY
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
STAIR
STORAGE
OFFICE
10A
MECH
ELECT
OFFICE
OFFICE 3
OFFICE
MECH
C0W
CORRIDOR
LOCKER
FEMALE
2A
BATH
HAC 1A
PHONE
STAIR
LOCKER
MALE
12A
BATH
C0E
CORRIDOR
LOBBY
3A
OFFICE
4A
OFFICE
5A
OFFICE
001A
TELECOM
ROOM
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -2
-R E
M a rk fo rt
.r v t
/2
/2
:2 :4
A
M
2-GI101
BASEMENT FLOOR INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
03/30/2022
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
BASEMENT 001A TELECOM ROOM DOMICILIARY TYPE B GROUP 1 CLASS II
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
1/8" = 1'-0"
BASEMENT - CONST BARRIER PLAN
N
0 8' 16'4'
-ASBESTOS-CONTAINING FIRE DOOR
-ASBESTOS-CONTAMINATED SOIL IN CRAWLSPACE
-ASBESTOS-CONTAINING WINDOW CAULK (OLD RESIDUAL CAULK)
-ASBESTOS-CONTAINING BLACK WALL ADHESIVE
CASTLE HILL ASSOCIATES, LLC.
N
S
W
E
LEGEND
BUILDING #2 - BASEMENT FLOOR PLAN
-POSITIVE SAMPLE LOCATION
-SAMPLE LOCATION
-ASBESTOS-CONTAINING WINDOW CAULK (OLD RESIDUAL CAULK)
-ASBESTOS-CONTAINING BLACK WALL ADHESIVE
-ASBESTOS-CONTAINING HARD FITTINGS ON FIBERGLASS
-ASBESTOS-CONTAINING BLACK TAR ON RAIN LEADER DOWNSPOUT
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND
BUILDING #2 - FIRST FLOOR PLAN
-ASBESTOS-CONTAINING WINDOW CAULK (OLD RESIDUAL CAULK)
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND BUILDING #2 - SECOND FLOOR PLAN
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
STAIR
STORAGE
OFFICE
10A
MECH
ELECT
OFFICE
OFFICE 3
OFFICE
MECH
C0W
CORRIDOR
LOCKER
FEMALE
2A
BATH
HAC 1A
PHONE
STAIR
LOCKER
MALE
12A
BATH
C0E
CORRIDOR
LOBBY
3A
OFFICE
4A
OFFICE
5A
OFFICE
001A
TELECOM
ROOM
2-AS100
5'-5"
'-1
0"
001A
TELECOM
ROOM
HAC
IN-03.01
3' -7
/2
2'
-6
5' -8
/2
001A
TELECOM
ROOM
TELECOM
ROOM
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -2
-R E
M a rk fo rt
.r v t
/2
/2
:2 :4
A
M
2-AS100
BASEMENT PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
1/8" = 1'-0"
BASEMENT FLOOR - OVERALL PLAN
N
0 8' 16'4'
1/4" = 1'-0"
ENLARGED FLOOR PLAN
N
0 4' 8'2'
1/4" = 1'-0"
PARTIAL DEMOLITION PLAN
N
0 8' 16'4'
1/4" = 1'-0"
REFLECTED CEILING PLAN
N
0 8' 16'4'
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
DE23 PREPARE EXISTING PARTITION FOR LEAK PREVENTION BARRIER. SEE
FLOOR PLAN AND SHEET AS601
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
FL21 OVERHEAD LEAK DIVERTER, SEE PLUMBING.
FL22 LEAK PREVENTION BARRIER WATERPROOFING DETAIL AT EXISTING
PARTITION. SEE AS601.
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1
RC1 RC2
DE1
DE1
FL1
FL22
FL3
FL21
FL20
FL3
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
ROOMS.
DE23
FL3
WS1WS2
WS3
WS6
WS5 WS4
VEST
101A
BEDROOM
BEDROOM 102
OFFICE
BEDROOM
STAFF
HAC
OFFICE
STATION
NURSE
WAITING
C1C
CORRIDOR
LOBBY
FEMALE
OFFICE
OFFICE
OFFICE
OFFICE
DIRECTOR
OFFICE
OFFICE
OFFICE
0FFICE
STAIR
116A
CHASE
PIPE
115A
CHASE
PIPE
131A
CHASE
PIPE
132A
CHASE
PIPE
105A
OFFICE
106A
DAYROOM
4 BED
4 BED
STAIR
3 BED
111A
BATH
2 BED
3 BED
C1E
CORRIDOR
STOR
104A
CHASE
PIPE
STAIR
BATH
SHOWER
ROOM
GROUP
STOR
BATH
MALE
BATH
FEMALE
ROOM
GROUP
OFFICE
ROOM
GROUP
STAIR
ROOM
GROUP
C1W
CORRIDOR135
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
GROUP
ROOM
GROUP
CONFERENCE
STAFF
OFFICE
OFFICE
PURPOSE
MULTI-
STATION
NURSE
105B
MEDROOM
EXAM
W D
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -2
-R E
M a rk fo rt
.r v t
/2
/2
:2 :3
A
M
2-AS110
FIRST FLOOR - OVERALL PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
N
0 8' 16'4'
1/8" = 1'-0"
FIRST FLOOR - OVERALL PLAN
N
0 8' 16'4'
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
ROOMS.
3 BED
1 BED
1 BED
1 BED
1 BED
1 BED
1 BED
C2C
CORRIDOR
STAIR
LINEN
CLEAN
2 BED
229A
EFFECTS
PATIENT
LOBBY
2 BED
LAUNDRY
1 BED
243A
CHASE
PIPE
1 BED
2 BED
205A
BATH
OFFICE
STAIR
HAC
1 BED
1 BED
235A
CHASE
PIPE
219A
CHASE
PIPE
220A
CHASE
PIPE
205B
CHASE
PIPE
2 BED
2 BED
2 BED
4 BED
2 BED
4 BED
C2E
CORRIDOR
STAIR
4 BED
4 BED
3 BED
NURSE
BATH
SHOWER
4 BED
NURSE
BATH
SHOWER
4 BED
3 BED
4 BED
4 BED
STAIR
C2W
CORRIDOR
3 BED
4 BED
4 BED
2 BED
2 BED
OFFICE
OFFICE
D W
DN
UP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -2
-R E
M a rk fo rt
.r v t
/2
/2
:2 :3
A
M
2-AS120
SECOND FLOOR - OVERALL
PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
1/8" = 1'-0"
SECOND FLOOR - OVERALL PLAN
N
0 8' 16'4'
N
0 8' 16'4'
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
ROOMS.
CONNECTION BETWEEN
FIRE ALARM PANELS
ANNUNCIATOR
PIPE TO FIRST FLOOR
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
STAIR
STORAGE
OFFICE 10A
MECH
ELECT
OFFICE
OFFICE 3
OFFICE
MECH
C0W
CORRIDOR
LOCKER
FEMALE
2A
BATH
HAC 1A
PHONE
STAIR
LOCKER
MALE
12A
BATH
C0E
CORRIDOR
LOBBY
3A
OFFICE
4A
OFFICE
5A
OFFICE
WATER
MAIN VALVE
C C
2-TN300
LIMITS OF DATA CABLING DEMOLITION
WAP
WAP
4D 4D 4D
4D 4D 4D 4D
4D
2V
2V
E
E
E E
E
EE
E E
E
E
E
E
E E
E
E E
E
E
E
E E
E
WAP
WAP
WAP
WAP
4D
4D 4D4D
4D
4D
E 12"x2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:1
P
M
2-TD100
BASEMENT FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
N
0 8' 16'4'
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
WS3
WS6
WS5 WS4
VEST
101A
BEDROOM
BEDROOM 102
OFFICE
BEDROOM
STAFF
HAC
OFFICE
STATION
NURSE
WAITING
C1C
CORRIDOR
LOBBY
FEMALE
OFFICE
OFFICE
OFFICE
OFFICE
DIRECTOR
OFFICE
OFFICE
OFFICE
0FFICE
STAIR
116A
CHASE
PIPE
115A
CHASE
PIPE
131A
CHASE
PIPE
132A
CHASE
PIPE
105A
OFFICE
106A
DAYROOM
4 BED
4 BED
STAIR
3 BED
111A
BATH
2 BED
3 BED
C1E
CORRIDOR
STOR
104A
CHASE
PIPE
STAIR
BATH
SHOWER
ROOM
GROUP
STOR
BATH
MALE
BATH
FEMALE
ROOM
GROUP
OFFICE
ROOM
GROUP
STAIR
ROOM
GROUP
C1W
CORRIDOR135
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
GROUP
ROOM
GROUP
CONFERENCE
STAFF
OFFICE
OFFICE
PURPOSE
MULTI-
STATION
NURSE
105B
MEDROOM
EXAM
W D
WS1WS2
WS3
WS6
WS5 WS4
VEST
101A
BEDROOM
BEDROOM 102
OFFICE
BEDROOM
STAFF
HAC
OFFICE
STATION
NURSE
WAITING
C1C
CORRIDOR
LOBBY
FEMALE
OFFICE
OFFICE
OFFICE
OFFICE
DIRECTOR
OFFICE
OFFICE
OFFICE
0FFICE
STAIR
116A
CHASE
PIPE
115A
CHASE
PIPE
131A
CHASE
PIPE
132A
CHASE
PIPE
105A
OFFICE
106A
DAYROOM
4 BED
4 BED
STAIR
3 BED
111A
BATH
2 BED
3 BED
C1E
CORRIDOR
STOR
104A
CHASE
PIPE
STAIR
BATH
SHOWER
ROOM
GROUP
STOR
BATH
MALE
BATH
FEMALE
ROOM
GROUP
OFFICE
ROOM
GROUP
STAIR
ROOM
GROUP
C1W
CORRIDOR135
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
GROUP
ROOM
GROUP
CONFERENCE
STAFF
OFFICE
OFFICE
PURPOSE
MULTI-
STATION
NURSE
105B
MEDROOM
EXAM
W D
C
C
C
C
C
C
C
C
C
C
C
C
C
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 001A
2V 2V 2V 2V
2D
2V 2V
2D
2V 2V
2D
2V
2D
2V
2D
2D
2V
2D
2V1D
2D/2V
2D
2V
2D2D
2V 2V
2D
2V
2V 2V
2V
2D
2V
2D
2V
2V
2V 2V
2V
2V
2V
2V4D
4D
2V
2V4D
2V
2V
2V
2V
4D 4D
2V
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
EE
E
E
E E E E
E
E E
E
E
E
E
E
E
E
E E
E
E
E
E E
E
E
E E
E
E
E E E
E E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E E E
E E E
E E E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
2V
2V
1D
2V
2V
2V
2D/2V2V
2V
2D/2V
WAP
2D/2V 2D/2V
1D/1V2D
2D
2D 2D 2D/2V
1D/1V 2D
2D
2D
4D
2V
4D
4D
2D 2D
2D
WAP
E
E
E
E
2V
2V
2V
2V
2V2D
EE
EE
E 2V
2D 2D
EE
E
E
E
E
E
E
E
E
E
E
EE
12"x2"
"x
2"
12"x2"
"x
2"
"x
2"
12"x2"
"x
2"
12"x2"
"x
2"
"x
2"
"x
2"
E
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
2-TD110
FIRST FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOM - DEMOLITION
N
0 8' 16'4'
N
0 8' 16'4'
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
1 BED
1 BED
1 BED
1 BED
1 BED
1 BED
C2C
STAIR
LINEN
CLEAN
2 BED
229A
EFFECTS
PATIENT
LOBBY
2 BED
LAUNDRY
1 BED
243A
CHASE
PIPE
1 BED
2 BED
205A
BATH
OFFICE
STAIR
HAC
1 BED
1 BED
235A
CHASE
PIPE
219A
CHASE
PIPE
220A
CHASE
PIPE
205B
CHASE
PIPE
2 BED
2 BED
2 BED
4 BED
2 BED
4 BED
C2E
CORRIDOR
STAIR
4 BED
4 BED
3 BED
NURSE
BATH
SHOWER
4 BED
NURSE
BATH
SHOWER
4 BED
3 BED
4 BED
4 BED
STAIR
C2W
CORRIDOR
3 BED
4 BED
4 BED
2 BED
2 BED
OFFICE
OFFICE
DN
UP
C
C
C
C
CC
C
C
C
C
LIMITS OF DATA CABLING DEMOLITION
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
2V
2V
2V
2V
2V
2V
2V
2V
3D
2D/2V
2D/2V
2D/2V
2D/2V
2V
2V
2V
2V
2V 2V
2V
2D
2V 2V 2V 2V 2V
2D/2V
3D
2V
2V
2V
2V
2V 2V2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
EE E E E
E E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E E
E
E
E E
E
EE
E
2V
2V
2V
2V 2V
2V
2V
WAP
WAP
2V
2V
2V
2V
2V
2V2V
2V
2V 2V
2V
2V
2V
2V
2V
2V 2V
2V
2V
2V
2V
2V2D/2V
WAP
2V 2V
2V
E E
E
E E E E E E E EE
E
E
E 2V
2V
2V 2V 2V 2V 2V 2V 2V 2V 2V2V
E
E
E E
E
EE
E
E
E
E
E E
E
E
12"x2"
"x
2"
"x 2"
12"x2"
"x
2"12 "x
2"
12"x2"
"x
2"
"x 2"
E
12"x2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
2-TD120
SECOND FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOM - DEMOLITION
N
0 8' 16'4'
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
DN
ATTIC
2' X 2' ATTIC HATCH
2' X 2' ATTIC HATCH
LIMITS OF DATA CABLING DEMOLITION
E E E
E E D V
WAP WAP WAP
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
2-TD130
THIRD FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
THIRD FLOOR PLAN - TELECOM - DEMOLITION
N
0 8' 16'4'
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
STAIR
STORAGE
OFFICE 10A
MECH
ELECT
OFFICE
OFFICE 3
OFFICE
MECH
C0W
CORRIDOR
LOCKER
FEMALE
2A
BATH
HAC 1A
PHONE
STAIR
LOCKER
MALE
12A
BATH
C0E
CORRIDOR
LOBBY
3A
OFFICE
4A
OFFICE
5A
OFFICE
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
STAIR
STORAGE
OFFICE 10A
MECH
ELECT
OFFICE
OFFICE 3
OFFICE
MECH
C0W
CORRIDOR
LOCKER
FEMALE
2A
BATH
HAC 1A
PHONE
STAIR
LOCKER
MALE
12A
BATH
C0E
CORRIDOR
LOBBY
3A
OFFICE
4A
OFFICE
5A
OFFICE
C C
001A
TELECOM ROOM
2-TN400
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 001A
4D 4D 4D
4D 4D 4D 4D
4D
2V
2V
WAP
WAP
E
E
E E
E
EE
E E
E
E
E
E 12"x2"12"x2"
2"
2"
4D
4D 4D4D
4D
E E
E
E E
WAP
WAP
E
E
4D E
E
WAP
WAP
E
E
C4 126"
E
4"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
2-TN100
BASEMENT FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
2. PROVIDE JUNCTION BOX TO CONNECT FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO THE NEW
TELECOM ROOM.
1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
N
0 8' 16'4'
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
C
C
C
C
C
C
C
C
C
C
C
C
WS1WS2
WS3
WS6
WS5 WS4
VEST
101A
BEDROOM
BEDROOM 102
OFFICE
BEDROOM
STAFF
HAC
OFFICE
STATION
NURSE
WAITING
C1C
CORRIDOR
LOBBY
FEMALE
OFFICE
OFFICE
OFFICE
OFFICE
DIRECTOR
OFFICE
OFFICE
OFFICE
0FFICE
STAIR
116A
CHASE
PIPE
115A
CHASE
PIPE
131A
CHASE
PIPE
132A
CHASE
PIPE
105A
OFFICE
106A
DAYROOM
4 BED
4 BED
STAIR
3 BED
111A
BATH
2 BED
3 BED
C1E
CORRIDOR
STOR
104A
CHASE
PIPE
STAIR
BATH
SHOWER
ROOM
GROUP
STOR
BATH
MALE
BATH
FEMALE
ROOM
GROUP
OFFICE
ROOM
GROUP
STAIR
ROOM
GROUP
C1W
CORRIDOR135
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
GROUP
ROOM
GROUP
CONFERENCE
STAFF
OFFICE
OFFICE
PURPOSE
MULTI-
STATION
NURSE
105B
MEDROOM
EXAM
W D
VERTICAL ROUTE
TO ROOM 001A
4"
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
E
E
E
E
E
E
E
E
E
E
E
E
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 001A
12"x2"12"x2"
12"x2"
12"x2"
C1 126" 4"
2D
2V 2V
2V
2D
2V 2V
2D 2D
2V 2V 2V
2D
2V 2V
EE
E
EE
E
E
E E E E
E
E E
E
2D
2V
2D
E
E
E
2V1D E
E 2D/2V
2V
2D 2D
2V 2V
2D 2D
2V
E
E E
E
E
E
E E
E
E
E
E
E
E 2V 2V 2D
2V 2V
E E E
E E
2D
2V
E
E
E
2V
2V
2V
E
E
E
2V
2V
2V E
E
E
E
E
E
4D
4D
E
E
4D
4D 4D
E
E E
2V
2V
2V
2V
2V
2V
2V
2V
E
E
E
E
E
E
E
E
WAP
E
2V
2V
1D
2V
2V
2V
2D/2V2V
2D/2V
2V
E
E
E
E
E
E
E
EE
E
2D/2V 2D/2V
E E
2D
2D
2D 2D 2D/2V
2D
2D
2D1D/1V1D/1V
E
E E E
E E E
E
E
E
E
E
E
E
WAP
E
2V E
4D
4D
2D 2D
2D
E
E
E
E E
4D E
2V
2V
2V
2V
E
E
E
E
2D 2V E E
2V
2D 2D E
E
E
12"x2"
"x
2"
"x 2"
12"x2"
"x
2"
"x 2"
EE
E
E
E
E
E
E
E
E
E
E
E
E E
"x
2"
"x
2"
F2
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
2-TN110
FIRST FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOMMUNICATIONS
N
0 8' 16'4'
N
0 8' 16'4'
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
1 BED
1 BED
1 BED
1 BED
1 BED
1 BED
C2C
CORRIDOR
STAIR
LINEN
CLEAN
2 BED
229A
EFFECTS
PATIENT
LOBBY
2 BED
LAUNDRY
1 BED
243A
CHASE
PIPE
1 BED
2 BED
205A
BATH
OFFICE
STAIR
HAC
1 BED
1 BED
235A
CHASE
PIPE
219A
CHASE
PIPE
220A
CHASE
PIPE
205B
CHASE
PIPE
2 BED
2 BED
2 BED
4 BED
2 BED
4 BED
C2E
CORRIDOR
STAIR
4 BED
4 BED
3 BED
NURSE
BATH
SHOWER
4 BED
NURSE
BATH
SHOWER
4 BED
3 BED
4 BED
4 BED
STAIR
C2W
CORRIDOR
3 BED
4 BED
4 BED
2 BED
2 BED
OFFICE
OFFICE
D W
DN
UP
3 BED
1 BED
1 BED
1 BED
1 BED
1 BED
1 BED
C2C
CORRIDOR
STAIR
LINEN
CLEAN
2 BED
229A
EFFECTS
PATIENT
LOBBY
2 BED
LAUNDRY
1 BED
243A
CHASE
PIPE
1 BED
2 BED
205A
BATH
OFFICE
STAIR
HAC
1 BED
1 BED
235A
CHASE
PIPE
219A
CHASE
PIPE
220A
CHASE
PIPE
205B
CHASE
PIPE
2 BED
2 BED
2 BED
4 BED
2 BED
4 BED
C2E
CORRIDOR
STAIR
4 BED
4 BED
3 BED
NURSE
BATH
SHOWER
4 BED
NURSE
BATH
SHOWER
4 BED
3 BED
4 BED
4 BED
STAIR
C2W
CORRIDOR
3 BED
4 BED
4 BED
2 BED
2 BED
OFFICE
OFFICE
D W
DN
UP
C
C
C
C
CC
C
C
C
C
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 001A
HORIZONTAL AND VERTICAL
ROUTE TO ROOM 001A
C1 126"
4"4"
12"x2"
12"x2"2V
2V
2V
2V
E
E
E
E
2V
2V
2V
2V
E
E
E
E
2D/2V
2D/2V E
E
2D/2V E
2V
2V
2V
2V
E
E
E
E
3D E
2D/2V E
2V2V
EE
2D
2V
E
E
EE
2V 2V 2V 2V 2V E E E
2V
2V
2V
2V E E
E
E
3D E
2D/2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
2V
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
2V
2V
2V
2V 2V
2V
2V
2V
2V
2V
2V
2V
2V
2V2V E E
E
E E
E
E
E
E
E
E
E
E
E
E
WAP
WAP
E
E
2D/2V E
2V
2V 2V
E E
E
2V
2V
2V E
E
E
2V
2V 2V
2V
2V
2V
2V
2V
E
E
E
E E
E
EE
WAP
E
2V
2V
2V
E E
E
2V 2V 2V 2V 2V 2V 2V E E E E E E E
2V 2V
EE
E
E
E 2V
2V
2V
"x
2"
"x 2"
"x
2"
"x 2"
12"x2"12"x2"
E
E E
E
EE
E
E
E
E
E E
"x
2"
"x
2"
E E
F2
12"x2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
2-TN120
SECOND FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOMMUNICATIONS
N
0 8' 16'4'
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
DN
ATTIC
2' X 2' ATTIC HATCH
2' X 2' ATTIC HATCH
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 001A
HORIZONTAL AND VERTICAL
ROUTE TO ROOM 001A
4"
WAP WAP WAP
E E E
D V E E
4" DOWN
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
2-TN130
THIRD FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
THIRD FLOOR PLAN - TELECOMMUNICATIONS
N
0 8' 16'4'
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
STAIR
STORAGE
OFFICE 10A
MECH
ELECT
OFFICE
OFFICE 3
OFFICE
MECH
C0W
CORRIDOR
LOCKER
FEMALE
2A
BATH
HAC 1A
PHONE
STAIR
LOCKER
MALE
12A
BATH
C0E
CORRIDOR
LOBBY
3A
OFFICE
4A
OFFICE
5A
OFFICE
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
STAIR
STORAGE
OFFICE 10A
MECH
ELECT
OFFICE
OFFICE 3
OFFICE
MECH
C0W
CORRIDOR
LOCKER
FEMALE
2A
BATH
HAC 1A
PHONE
STAIR
LOCKER
MALE
12A
BATH
C0E
CORRIDOR
LOBBY
3A
OFFICE
4A
OFFICE
5A
OFFICE
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
2-TN200
BASEMENT FLOOR PLAN -
TELECOM - CABLE DISTANCE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1" = 30'-0"
BASEMENT FLOOR PLAN - TELECOMMUNICATIONS - CABLE DISTANCE
N
0 30' 60'15'
AC
AC
TW
E
D
SP
E
E
E
PS
E
CABLE
TRAY
DATA
RACK
E
D
E
D
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
2-TN300
ENLARGED PLAN -
TELECOMMUNICATIONS -
DEMO
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/4" = 1'-0"
ENALRGED PLAN - EXIST RM 001A - TELECOM - DEMO
0 4' 8'2'
N
SHEET NOTES:
1. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.
EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING
COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE
RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT.
1. ROOM 001A
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 251
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
CR
AC
001A
TELECOM ROOM
2-TN400
1 - a b
1 - c d
PS
AC
TW
AC
SP
E
E
E
E
E
C4 126" 2"
DATA RACK
CABLE TRAY
12"x4"
"x
4"
12"x4"
"x
4"
"x
4"
E
KEYPAD
W
E
F2
R
NOTES:
1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.
4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO
SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).
5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.
7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.
VERTICAL CABLE
MANAGEMENT (TYP)
RACK 1
1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL
1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)
1U 48 PORT CAT5E BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
1U CABLE MANAGEMENT
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
6U 5KW RACK MOUNT UPS
6U SPACE FOR FUTURE USE. PROVIDE BLANK
PANELS FOR UNUSED SPACES.
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
NEMA L21-20R (TYP)
CHANNEL RACK (TYP)
D
PROVIDE DATA CABLE TO RACK
MOUNTED UPS FOR CONNECTION
TO MONITORING SYSTEM
RACK 1
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
SPACE FOR FUTURE HORIZONTAL CABLE
DISTRIBUTION. PROVIDE BLANKING PANELS FOR
UNUSED SPACES.
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
2-TN400
ENLARGED PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 2' 4'1'
0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
1. ROOM 001A
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 251
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6A): 251
DATA (CAT6): 0
1/2" = 1'-0"
ENLARGED PLAN - TR 001A - TELECOM - CABLE TRAY AND DATA
1/4" = 1'-0"
1 - a
1/4" = 1'-0"
1 - b
1/4" = 1'-0"
1 - c
1/4" = 1'-0"
1 - d
NOT TO SCALE
COMMUNICATIONS - TYPICAL ONE RACK ELEVATION WITH RACK MOUNT UPS - RM 001A
B O
O K
S
B O
O K
S
B O
O K
S
B O
O K
S
BOOKS
X
D
E S
K
X
D
E S
K
X
D
E S
K
30X66
DESK
X
D
E S
K
X
D
E S
K
24X48 24X48 24X48
X
24X48 24X48
LA
T FILE
LA
T FILE
LA
T FILE
B O
O K
S
LA
T FILE
LA
T FILE
LA
T
FI
LE
WATER
MAIN VALVE
TELECOM ROOM
001A 02-E300
02-E300
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:2
:2
A M
02-E200
BASEMENT FLOOR PLAN -
ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
1/8" = 1'-0"
BASEMENT FLOOR PLAN - ELECTRICAL
N
100% CD 03/30 05-06-2022
E
WS3
WS6
WS5 WS4
OFFICE
STAIR
GROUP
ROOM
GROUP
ROOM
VENDING
GROUP
ROOM
OFFICE
MULTI-
PURPOSE
DIRECTOR
OFFICE
OFFICE
GROUP
ROOM
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
C1W
OFFICE
STORAGE
PIPE CHASE
131A
FEMALE
TOILET
MALE
TOILET
OFFICE
OFFICE
STAIR
HALL
OFFICE
ELEVATOR
LOBBY
OFFICE
OFFICE
FEMALE
OFFICE
PIPE CHASE
132A
GROUP ROOM
OFFICE
105A
PIPE
CHASE
104A
BEDROOM
BEDROOM
101A
4 BED
VEST.
DAYROOM
106A
4 BED
STAIR
CORRIDOR
C1C
WAITING
OFFICE
NURSING
OFFICE
CORRIDOR
C1E
STAFF
HAC
119 STAIR
HALL
PIPE CHASE
116A
3 BED
TOILET
LAUNDRY/
SHOWER
PIPE CHASE
115A
GROUP
ROOM
TOILET
111A
2 BED
111 3 BED
BEDROOM
STOR
OFFICE
MEDROOM
105B
EXAM
W D
BUILDING 2 1ST FLOOR
LAST UPDATED: 4-28-20
15,715 EXISTING G.S.F.
B02IT-1-CR-11
WP
CU-2-1
B02IT-1-CR-7,9
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:2
:3
A M
02-E201
FIRST FLOOR PLAN -
ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
1/8" = 1'-0"
FIRST FLOOR PLAN - ELECTRICAL
KEYNOTES:
1. PROVIDE ELECTRICAL CONNECTION TO
CONDENSING UNIT, AS REQUIRED.
COORDINATE FINAL LOCATION AND
CONNECTION REQUIREMENTS WITH
MECHANICAL.
N
100% CD 03/30 05-06-2022
SD
E
TELECOM ROOM
001A
AC-2-1
B02IT-1-CR-1,3,5
2MDP
(20A/3P)
B02IT-1-CR
2ES
ATS-CR
ATS-LS
2EC
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:2
:3
A M
02-E300
ELECTRICAL ENLARGED
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
N O R
HT
1/4" = 1'-0"
BASEMENT ENLARGED - 001A -
POWER AND SYSTEM
KEYNOTES:
1. INDOOR UNIT TO BE POWERED BY OUTDOOR
UNIT. COORDINATE EXACT LOCATION WITH
M.C.
2. CONNECT SMOKE DETECTOR TO NEAREST
EXISTING SLC.
3. COORDINATE FINAL LOCATION OF
RECEPTACLE L21-20R WITH TELECOM
CONTRACTOR. PROVIDE 3/4"C-4#12, 1#12 GND
TO PANEL FOR EACH RECEPTACLE.
4. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-
PHASE,4-WIRE RACK MOUNTED UPS FOR EACH
RACK TOWER.
5. PROVIDE APC#AP8861 RPDU RACK PDU 2G
WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,
ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R
OUTLETS. PROVIDE TWO PER RACK, MOUNTED
PER MANUFACTURER'S REQUIREMENTS.
6. VERIFY EXACT CIRCUIT AVAILABILITY IN PANEL
AND REARRANGE BREAKERS TO ALLOW 3
CONSECUTIVE SPACES.
4 5
SHEET NOTES:
1. REFER TO TECHNOLOGY PLANS FOR IT ROOM
LAYOUT AND RACK LAYOUT/DETAILS.
2. REFER TO SHEET 0-GE400 DETAIL FOR LAYOUT
& ONE-LINE OF RACK.
N O R
HT
1/4" = 1'-0"
BASEMENT ENLARGED -
ELECTRICAL - MECH 11
0 4' 8'2' 0 4' 8'2'
NN
100% CD 03/30
05-06-2022
BASEMENT
FIRST FLOOR
B02IT-1-CR
60Y
2EC
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:2
:3
A M
02-E400
ELECTRICAL DIAGRAMS &
SCHEDULE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
12" = 1'-0"
PARTIAL POWER RISER
KEYNOTES:
1. REMOVE EXISTING 20A/3P SPARE CIRCUIT
BREAKER AND INSTALL NEW 60A/3P CIRCUIT
BREAKER TO MATCH EXISTING TYPE AND AIC
RATING.
100% CD 03/30
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 19.9 A
TOTAL CONNECTED AMPS: 19.93 A
TOTAL ESTIMATED DEMAND LOAD: 7.18 kVA
Receptacles 0.18 kVA 100.00% 0.18 kVA TOTAL CONNECTED LOAD: 7.18 kVA
Power 7 kVA 100.00% 7 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 23.27 23.27 15.39
Total Load: 2.67 kVA 2.67 kVA 1.85 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --
-- 9 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 10 --
7 CU-2-1 20 A 2 1 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 60 A MCB
PANEL B02IT-1-CR
2EC
05-06-2022
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/2
/2
:5
:0
A
M
02-E500
ELECTRICAL SCHEDULES
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
TBD GJL
16305
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 19.9 A
TOTAL CONNECTED AMPS: 19.93 A
TOTAL ESTIMATED DEMAND LOAD: 7.18 kVA
Receptacles 0.18 kVA 100.00% 0.18 kVA TOTAL CONNECTED LOAD: 7.18 kVA
Power 7 kVA 100.00% 7 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 23.27 23.27 15.39
Total Load: 2.67 kVA 2.67 kVA 1.85 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --
-- 9 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 10 --
7 CU-2-1 20 A 2 1 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 60 A MCB
PANEL B02IT-1-CR
2EC
100% CD 03/30
53095
T
1"CW
4"LPS
1-1/2" COND
C O
N D
3" COND
BATH
2A
HSKP CLOSET
PHONE
1A
REMOVE EXISTING
IRRIGATION LINE AND
PREPARE PIPING FOR NEW
CONNECTIONS.
BEDROOM
STAFF
PIPE CHASE
104A
OFFICE
105A
OFFICE
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTA ARCHITECT/ENGINEER OF STAM
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 1
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/1
/2
:0
:4
P
M
02-M100
BASEMENT AND FIRST
FLOOR DEMOLITION -
MECHANICAL
EHRM
INFRASTRUCTURE
UPGRADES
656-21-235
RDL DJC
12345
1/2" = 1'-0"
BASEMENT DEMOLITION - MECHANICAL - TELECOM 001A
KEYNOTES 1/02-M100:
1. REMOVE AND DISPOSE OF EXISTING CEILING DIFFUSER AND BRANCH DUCT
SECTION IN THIS AREA. CAP DUCT WHERE SHOWN ON PLAN.
2. EXISTING 3" WASTE TO REMAIN.
3. EXISTING 1" IRRIGATION LINE. TO BE REROUTED. SEE SHEET 02-M200 FOR NEW PIPE
ROUTING.
4. EXISTING 1-1/2" CONDENSATE TO REMAIN.
5. EXISTING 3/4" DRIP PAN DRAIN LINE TO REMAIN.
6. EXISITING 4" LOW PRESSURE STEAM TO REMAIN.
7. REMOVE AND DISPOSE OF EXISTING THERMOSTAT.
8. EXISTING DRIP PAN TO REMAIN.
FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT
THEIR BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE OF
WORK, WHETHER EXPLICITLY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.
E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING.
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL OF THESE ITEMS PRIOR TO BID AND INCLUDE IN
THEIR BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.
3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.
4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
ARCHITECT FOR DIRECTION.
0 2' 4'1'
N
1/2" = 1'-0"
FIRST FLOOR DEMOLITION - MECHANICAL
N
0 2' 4'1'
100% CD 03/2
T
TELECOM ROOM
001A
PROPOSED
RACK
LOCATION
AC-2-1
CP-2-1
3/4" PC
3"D
1-1/2" COND
C O
N D
1"CW
4"LPS
3" COND
BATH
2A
HSKP CLOSET
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTA ARCHITECT/ENGINEER OF STAM
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 1
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/1
/2
:0
:5
P
M
02-M200
BASEMENT FLOOR
REMODEL - MECHANICAL
EHRM
INFRASTRUCTURE
UPGRADES
656-21-235
RDL DJC
12345
1/2" = 1'-0"
BASEMENT FLOOR - MECHANICAL- TELECOM 001A
KEYNOTES 1/02-M200:
1. NEW WALL-MOUNTED DUCTLESS COOLING UNIT AC-2-1.
2. CAP SUPPLY AIR DUCT IN THIS AREA.
3. ROUTE NEW REFRIGERANT PIPING UP TO GRADE LEVEL - SEE SHEET 02-M201 FOR
CONTINUATION.
4. PROVIDE NEW THERMOSTAT.
5. ROUTE NEW CONDENSATE DRAIN PIPING TO FLOOR DRAIN IN MECH A10.
APPROXIMATELY 100 FT TO THE WEST. FIELD VERIFY EXACT ROUTING.
6. REROUTED 1" IRRIGATION LINE. FIELD VERIFY REQUIREMENTS.
7. EXISTING DRIP PAN AND DRAIN LINE TO REMAIN.
8. PROVIDE NEW CONDENSATE DRIP PAN FOR ALL CONDENSATE PIPING. SEE DETAIL
6/0-GM400 FOR REQUIREMENTS.
9. EXISTING 1 1/2" CONDENSATE DRAIN LINE.
10. EXISTING 4" LOW PRESSURE STEAM TO REMAIN.
FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING
CONDITIONS WHICH MAY AFFECT THEIR BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE OF
WORK, WHETHER EXPLICITLY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.
E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING.
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR…
This is the start of the file's text. The full file is on GovTribe.