Atch 21 - BLDG 48.pdf
PDF 11 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
- Solicitation number
- 36C77622B0035
About this file
This government file includes a solicitation for the Y1AZ--EHRM Infrastructure Upgrades Construction project at the St. Cloud Veterans Affairs Health Care System. The solicitation seeks a contractor to furnish all labor, materials, tools and equipment for infrastructure improvements including electrical, bonding, UPS, building management system interfaces, access security, HVAC upgrades and expansions, data center/main server room physical security upgrades, installation of a diversified path to the data center for the WAN, and access and upgrade of the fiber infrastructure backbone campus wide within and between buildings. The solicitation also requires hazardous materials abatement. All work must be completed in accordance with the specifications and contract drawings. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center Austin.
View the file
Other files for this federal contract opportunity
Show all 50
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING FIBER - INSIDE
VFY EXIST
EXISTING FIBER - OUTSIDE
VFY EXIST
FIBER ROUTE - INSIDE
SEE TELECOM
FIBER ROUTE - OUTSIDE
SEE CIVIL
BUILDING OUTLINE
VFY EXIST
CORRIDOR OUTLINE
VFY EXIST
LEGEND
TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST
44TH AVE.
TRAIL 1
TRAIL 2
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2)
15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
GRAVEL
GRAVEL
GRAVEL
EXISTING
ROAD
CHAIN LINK FENCE
CHAIN LINK FENCE
16' GATE
GRAVEL
ELECTRICAL
SUBSTATION
G E N E R A T O R
FUEL LINES
CONDU ITS TO TU NNEL
M V
D U
C T
B A
N K
1 1 2 W
PHARMACY ADDITION
11 2 E
G E N E R A T O R
B
CORRIDOR LINK
A
C T
TR
A
IL
ER
174 s .f.
256 s .f.
185 s .f.
149 s ..f.
155 s .f.
104 s .f.
70 s. .f .
72 s .f.
110 s .f.
276 s .f.
112 s .f.
99 s .f.
57 s .f.
146 s .f.
434 s .f.
R A
MP
U P
1:
M A X
R A
MP
U P
1:
M A X
RA
M P
UP
1:2 0 M
AX
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2) 15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
.3
TRANSFORMER
BUILD ING
#91
5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN
O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW
C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D
P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S
R EC O M M EN D ATIO N S
N EW G AS SU P P LY M AIN
IN TO B U ILD IN G
SP AR E
P H O N E LIN E
EXTEN D S TO
E XISTIN G
P H O N E IN
B O ILER R O O M
P ER P LAN .
SP AR E
P H O N E
LIN E TO
M ETER
TU N N EL
E XTEN D S
A D D ITIO N AL
2'- 0" U N D ER
B U ILD IN G
FUEL LINE
VENT LINE
1,000 GAL.
UNDERGROUND
DIESEL FUEL
TANK
1,000/5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
S 1
LIG H T
N EW G AS SU P P LY
(C O O R D IN ATE W ITH SU P P LIER )
12"D
10"D
"D
TP TP
EXIST. BUILDING
EXIST.
BUS STOP
CC
L O
O P
16"
20"
12"
3"
8"
DN
BIRDCAGE
B
IR
D C
A G
E
NSP ELECTRICAL
FOR HWY DEPT
T101
I.T.
CHILLER
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
VESTIBULE
DN
DN
DN
FD
DN
F B
F
B
F B
F
B
F B
F
B
SOUTH
VESTIBULE
PASS
THROUGH
LINK TO
BUILDI NG 51
6 3. 32 56
1 13 5. 35 78
PARKING
NO
PARKING
93 49
37 6
109 5
1A
S M
O K
E B
L D
G
SMOKE
BLDG
SMOKE
BLDG
S M
O K
E B
L D
G
SMOKE
BLDG
M.H.
STOR.
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
STOR.
BIO-
HAZ.
SAUK RIVER
GP
HOLDING POND
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
OWNER AND
CONSULTANTS:
CONTACT:
ADDRESS:
MIKE ENGMARK
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
NAME:
ADDRESS:
CONTACT:
ADVANCED STRUCTURAL TECHNOLOGIES
7301 OHMS LANE; SUITE 215
EDINA, MN 55439
ZACHARY CRAIG
PHONE:
NAME:
ADDRESS:
CONTACT:
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
PHONE: 402-991-5520
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
IAN WEBER
763-412-4000
ARCHITECT:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
EDWARD MARKFORT
763-412-4000
952-854-9302
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
402-991-5520
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
COVER
DATE:
APPROVED: APPROVED: PROJECTS SECTION MANAGER
APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:
APPROVED: SAFETY MANAGER
APPROVED: CHIEF OF POLICE
APPROVED: PATIENT SAFETY
DATE:
DATE:
DATE: APPROVED: EMS MANAGER
APPROVED: M/O MANAGER
DATE:
DATE:
DATE:DATE:
APPROVED: MEDICAL CENTER DIRECTOR
APPROVED: PROJECT COR DATE:
APPROVED: INFECTION CONTROL NURSE DATE:
APPROVED: SERVICE LINE DIRECTOR
APPROVED: GEMS COORDINATOR DATE:
DATE:
APPROVED: NURSE EXECUTIVE
APPROVED: CHIEF OF STAFF DATE:
APPROVED: DIRECTOR FMS
APPROVED: ASSOCIATE DIRECTOR
DATE:
DATE:
DATE:
DATE:APPROVED: DATE:
APPROVED: DATE:
APPROVED: DATE:
Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System
N
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
VICINITY MAP:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHONE: 320-252-1670
CIVIL ENGINEER:
VA COR:
TELECOMMUNICATIONS ENGINEER:
CONTACT:
ADDRESS:
JONATHAN WEST
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
PHONE: 504-250-2699
PROGRAM MANAGER:
EMAIL: Jonathan.West@vciint.com
STRUCTURAL ENGINEER:
MECH/ELEC/PLUMB/FIRE ENGINEER:
C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:4 :4
P
M
48-GI000
BUILDING 48 COVER SHEET &
SHEET INDEX
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM, BW
16305
BUILDING 48 - EHRM INFRASTRUCTURE UPGRADES
03/30/2022
0 150' 300'75'
SHEET INDEX - BUILDING 48
SHEET NO. SHEET TITLE
48-TN220 SECOND FLOOR PLAN - TELECOM - CABLE DISTANCE
48-TN400 ENLARGED PLANS - TELECOMMUNICATIONS
48-TN401 ENLARGED PLANS - TELECOMMUNICATIONS
48-E200 BASEMENT FLOOR PLAN - ELECTRICAL
48-E201 FIRST FLOOR PLAN - ELECTRICAL
48-E202 SECOND FLOOR PLAN - ELECTRICAL
48-E300 ELECTRICAL ENLARGED PLANS
48-E500 ELECTRICAL ONE-LINE DIAGRAMS
48-E600 ELECTRICAL SCHEDULES
48-M101 FIRST FLOOR DEMOLITION PLAN - MECHANICAL
48-M102 SECOND FLOOR DEMOLITION PLAN - MECHANICAL
48-M201 FIRST FLOOR PLAN - MECHANICAL
48-M202 SECOND FLOOR PLAN - MECHANICAL
SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION
SHEET INDEX - BUILDING 48
SHEET NO. SHEET TITLE
48-GI000 BUILDING 48 COVER SHEET & SHEET INDEX
48-GI110 FIRST FLOOR - LIFE SAFETY PLAN
48-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN
48-GI121 SECOND FLOOR - INFECTION CONTROL & PHASING PLAN
48-HA-1A REFERENCE - CRAWLSPACE FLOOR - ASBESTOS RE-SURVEY
48-HA-2A REFERENCE - BASEMENT FLOOR - ASBESTOS RE-SURVEY
48-HA-3A REFERENCE - FIRST FLOOR - ASBESTOS RE-SURVEY
48-HA-4A REFERENCE - SECOND FLOOR - ASBESTOS RE-SURVEY
48-HA-5A REFERENCE - THIRD ATTIC FLOOR - ASBESTOS RE-SURVEY
48-AS100 BASEMENT FLOOR - OVERALL PLAN
48-AS110 FIRST FLOOR PLANS
48-AS120 SECOND FLOOR PLANS
48-TD100 BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
48-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION
48-TD120 SECOND FLOOR PLAN - TELECOM - DEMOLITION
48-TD130 ATTIC FLOOR PLAN - TELECOM - DEMOLITION
48-TN100 BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
48-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS
48-TN120 SECOND FLOOR PLAN - TELECOMMUNICATIONS
48-TN130 ATTIC FLOOR PLAN - TELECOMMUNICATIONS
48-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
ROOM SCHEDULE
NO. NAME C
A
B
LI
N G
P A
T C
H P
A N
E L
F
IB
E R
P O
W E
R
B O
N D
IN
G
U P
S
D E
D
IC
A T
E D
C O
O
LI
N G
T E
M P
E R
A T
U R
E
H U
M
ID
IT
Y
R A
C K
S E
N S
O R
S P
A C
E
AREA
WIDTH
(FT)
LENGTH
(FT)
HT TO
CLG
STRUCT REMARKS
FIRST FLOOR
122A OFFICE 113 SF 8.00 MODIFIED FOR TELECOM ROOM, SEE MECH DRAWINGS
122B MED ROOM 74 SF MODIFIED FOR TELECOM ROOM, SEE MECH DRAWINGS
123 TELECOM ROOM X X X 157 SF 13.1 12.0 9.42 CONSTRUCT TO EHRM TELECOM ROOM STANDARDS.
SEE TELECOM DRAWINGS
SECOND FLOOR
221 TELECOM ROOM X X X X X X X X X 55 SF 9.2 6.0 10.50 CONSTRUCT TO EHRM TELECOM ROOM STANDARDS.
SEE TELECOM DRAWINGS
OPENING SCHEDULE
VA Building Number
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
48 OFFICE MED ROOM 122B 3'-0" 7'-0" WD-F NONE HMS-1 NONE HW-SH-3D.1 - Y Y Y
HAZARDOUS MATERIAL SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
QUESTIONABLE HAZARDOUS
ELEMENT POSSIBLE ABATEMENT ACTION
FIRST FLOOR 122A OFFICE NONE. SEE 48-HA-3A REMOVE HAZARDOUS MATERIAL UNDER FULL CONTAINMENT
FIRST FLOOR 122B MED ROOM ACM. SEE 48-HA-3A REMOVE HAZARDOUS MATERIAL UNDER FULL CONTAINMENT
FIRST FLOOR 123 TELECOM ROOM ACM. SEE 48-HA-3A REMOVE HAZARDOUS MATERIAL UNDER FULL CONTAINMENT
SECOND FLOOR 221 TELECOM ROOM NONE. SEE 48-HA-4A NONE. ABATEMENT COMPLETE UNDER SEPARATE CONTRACT
HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT
DISTURB QUESTIONABLE HAZARDOUS MATERIAL.
LEAK PREVENTION / DIVERTER SCHEDULE
LEVEL
ROOM
NO. ROOM NAME OVERHEAD LEAK DIVERTER AND DRAIN PIPING LEAK PREVENTION BARRIER WATERPROOFING
FIRST FLOOR 122A OFFICE
FIRST FLOOR 122B MED ROOM
FIRST FLOOR 123 TELECOM ROOM YES
SECOND FLOOR 221 TELECOM ROOM MWP INT: NORTH
SEE GENERAL NOTES SHEET FOR DETAIL. MWP = MEMBRANE WATERPROOFING. MASONRY = FLUID-APPLIED WATERPROOFING. INT = INTERIOR. EXT = EXTERIOR
ICRA PHASE CONSTRUCTION ROOM SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
CAI BLDG NAME /
FUNCTION
CONSTRUCTION
PROJECT ACTIVITY
INFECTION CONTROL
RISK GROUP
CONTROL
PROCEDURE CLASS SECTION
CONSTRUCTION ZONE /
OCCUPIED CONSTR
DAY /
NIGHT
FIRST FLOOR 122A OFFICE ADMINISTRATIVE / ADHC /
CLC
TYPE D GROUP 2 CLASS IV WEST ZONE48A NIGHT
FIRST FLOOR 122B MED ROOM ADMINISTRATIVE / ADHC /
CLC
TYPE D GROUP 2 CLASS IV WEST ZONE48A NIGHT
FIRST FLOOR 123 TELECOM ROOM ADMINISTRATIVE / ADHC /
CLC
TYPE D GROUP 2 CLASS IV WEST ZONE48B NIGHT
SECOND FLOOR 221 TELECOM ROOM ADMINISTRATIVE / ADHC /
CLC
TYPE C GROUP 1 CLASS II WEST OCCUPIED CONSTRUCTION NIGHT
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
MULTI
HAC
MULTI-
PURPOSE
FAX/
PRINTER
148A
OFFICE
NURSE'S
STATION
MEDS
147A
PATIENT
DINING
KITCHEN
DAYROOM
LAUNDRY
MALE/PATIENT
1 BED
EXERCISE
ROOM
1 BED
CLC
OFFICE
CLC
OFFICE
FILEROOM
1 BED
TOILET
STAIR
HALL
1 BED
1 BED
4 BED
1 BED
1 BED
PACT PT
TUB
ROOM
SHOWER
MALE
INTAKE
1 BED
2 BED
PURPOSE
PIPE CHASE
109A
PIPE CHASE
110A
CORRIDOR
C1W
STOR/MAIL
101A
1 BED
LOBBY
PIPE
CHASE
127A
ELEVATOR
149B
148B
CORRIDOR
C1C
HAC
STORAGE
KITCHEN
124A
TUB
ROOM
CORRIDOR
C1E
STAIR
HALL
PIPE CHASE
141A
PIPE CHASE
140A
SHOWER
1 BED
WHEELCHAIR
STORAGE
COAT
ROOM
4 BED
PIPE CHASE
109A
2 BED
1 BED
106B
DINING
1 BED
109B
149A
STAIR
124C
2 BED
106C
1 BED
106A
DN
DN
TELECOM
ROOM
122A
OFFICE
122B
MED ROOM
6"
T R
A V
E L
D
IS
T A
N C
E
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
HE
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EA
EDEXIT EXIT
HORIZONTAL EXIT
EXIT DISCHARGE
EXIT ACCESS
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
SMOKE
COMPARTMENT
BOUNDARY
HEALTH CARE
SUITE
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
OCCUPANCY
SEPARATION
SHAFT
ADJACENT SYMBOLS SHOW PARTITION RATING AND
DAMPER REQUIREMENTS
HAZARDOUS USE
ADJACENT SYMBOLS SHOW PARTITION RATING.
OPENINGS REQUIRE CLOSER & LATCH
EXIT PASSAGEWAY
RATE AS STAIR
ALL OPENINGS TO BE RATED AS STAIR SHAFT
CORRIDOR
WALLS TO LIMIT THE TRANSFER OF SMOKE
ADJUNCT CORRIDOR or PSYCHIATRIC AREA or CONSTRUCTED WITH MIN. 4'-0" CLEAR
WITH (PER CHAPTER 19)
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:4 :4
P
M
48-GI110
FIRST FLOOR - LIFE SAFETY
PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
03/30/2022
1/8" = 1'-0"1
FIRST FLOOR - LIFE SAFETY PLAN
0 8' 16'4'
N
MULTI-
PURPOSE
FAX/
PRINTER
148A
OFFICE
NURSE'S
STATION
MEDS
147A
PATIENT
DINING
KITCHEN
DAYROOM
LAUNDRY
MALE/PATIENT
1 BED
EXERCISE
ROOM
1 BED
CLC
OFFICE
CLC
OFFICE
FILEROOM
1 BED
TOILET
STAIR
HALL
1 BED
1 BED
4 BED
1 BED
1 BED
PACT PT
TUB
ROOM
SHOWER
MALE
INTAKE
1 BED
2 BED
PURPOSE
PIPE CHASE
109A
PIPE CHASE
110A
CORRIDOR
C1W
STOR/MAIL
101A
1 BED
LOBBY
PIPE
CHASE
127A
ELEVATOR
149B
148B
CORRIDOR
C1C
HAC
STORAGE
KITCHEN
124A
TUB
ROOM
CORRIDOR
C1E
STAIR
HALL
PIPE CHASE
141A
PIPE CHASE
140A
SHOWER
1 BED
WHEELCHAIR
STORAGE
COAT
ROOM
4 BED
PIPE CHASE
109A
2 BED
1 BED
106B
DINING
1 BED
109B
149A
STAIR
124C
2 BED
106C
1 BED
106A
DN
DN
TELECOM
ROOM
122A
OFFICE
122B
MED ROOM
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:4 :5
P
M
48-GI111
FIRST FLOOR - INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
03/30/2022
1/8" = 1'-0"
FIRST FLOOR - CONST BARRIER PLAN
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
FIRST FLOOR 122A OFFICE ADMINISTRATIVE / ADHC / CLC TYPE D GROUP 2 CLASS IV
FIRST FLOOR 122B MED ROOM ADMINISTRATIVE / ADHC / CLC TYPE D GROUP 2 CLASS IV
FIRST FLOOR 123 TELECOM ROOM ADMINISTRATIVE / ADHC / CLC TYPE D GROUP 2 CLASS IV
SECOND FLOOR 221 TELECOM ROOM ADMINISTRATIVE / ADHC / CLC TYPE C GROUP 1 CLASS II
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
STUDENTS
201A
PSM
NURSE
STUDENT
OFFICE
SECRETARY
STATION
LOBBY
BATHROOM
243A
FEMALE
TOILET
STORAGE
STAIR
HALL
STAIR
HALL
STORAGE
MALE
TOILET
STAIR
CONFERENCE
ROOM
TELEHEALTH
COORD
INFECTION
CONTROL
OFFICE
EMPTY
BIO-MED
STORAGE
226A CLC PROVIDER
OFFICE
BIOMED
BIOMED
BIOMED
213A
BIOMED
215B
STAGING
STAGING
TRAINING
OFFICE
207D
OFFICE
STUDENTS
207A
OFFICE
207B
OFFICE
207C
APPLICATIONS
OFFICE
OFFICE
224C
APPLICATIONS
VISN
OFFICE
MULTI-
PURPOSE
APPLICATIONS
EMPTY
OFFICE
OFFICE
237B
TRANSCRIPTION
OFFICE
PIPE CHASE
210A
PIPE CHASE
209A
I.T.
STOR.
DIRECTOR
STORAGE
233A
STORAGE
PIPE CHASE
236A
TOILET
203A
STORE
STORE
212A
BIOMED
PIPE CHASE
235A
OFFICE
OFFICE
232B
OFFICE
230A
OFFICE
232A
OFFICE
OFFICE
231A
OFFICE
HAC
CORRIDOR
C2W
CORRIDOR
C2C
CORRIDOR
C2E
CORRIDOR
C2N
STUDENTS
201B
TELECOM
ROOM
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:4 :5
P
M
48-GI121
SECOND FLOOR - INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
03/30/2022
1/8" = 1'-0"
SECOND FLOOR - CONST BARRIER PLAN
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
FIRST FLOOR 122A OFFICE ADMINISTRATIVE / ADHC / CLC TYPE D GROUP 2 CLASS IV
FIRST FLOOR 122B MED ROOM ADMINISTRATIVE / ADHC / CLC TYPE D GROUP 2 CLASS IV
FIRST FLOOR 123 TELECOM ROOM ADMINISTRATIVE / ADHC / CLC TYPE D GROUP 2 CLASS IV
SECOND FLOOR 221 TELECOM ROOM ADMINISTRATIVE / ADHC / CLC TYPE C GROUP 1 CLASS II
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
CASTLE HILL ASSOCIATES, LLC.
S
W E
NO ACM
BUILDING #48 - CRAWLSPACE FLOOR PLAN
-ASBESTOS-CONTAINING FIRE DOOR
-ASBESTOS-CONTAINING PIPE INSULATION (VERTICAL RISERS)
-ASBESTOS-CONTAINING MASTIC UNDER CARPET
-ASBESTOS-CONTAINING WINDOW CAULK AND INTERIOR GLAZING
-ASBESTOS-CONTAINING MASTIC UNDER 12"X12" FLOOR TILE
-ASBESTOS-CONTAINING PIPE INSULATION (HORIZONTAL RUNS)
-ASBESTOS-CONTAINING VENT CAULK
-ASBESTOS-CONTAINING BRICK SEAM CAULK
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND
BUILDING #48 - BASEMENT FLOOR PLAN
-ASBESTOS-CONTAINING PIPE INSULATION (VERTICAL RISERS)
-ASBESTOS-CONTAINING 9"X9" FLOOR TILE AND MASTIC
-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC UNDER CARPET
-ASBESTOS-CONTAINING MASTIC UNDER 12"X12" FLOOR TILE
-ASBESTOS-CONTAINING PIPE INSULATION (HORIZONTAL RUNS)
-ASBESTOS-CONTAINING WINDOW CAULK AND INTERIOR GLAZING
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
BUILDING #48 - FIRST FLOOR PLAN
-ASBESTOS-CONTAINING 9"X9" FLOOR TILE AND MASTIC
-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC UNDER CARPET
-ASBESTOS-CONTAINING MASTIC UNDER 12"X12" FLOOR TILE
-ASBESTOS-CONTAINING WINDOW CAULK AND INTERIOR GLAZING
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
BUILDING #48 - SECOND FLOOR PLAN
-ASBESTOS-CONTAINING DUCT SEAM SEALANT (BLACK)
DN
UP DN
UP
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
BUILDING #48 - ATTIC FLOOR PLAN
E.FD
EXISTING METAL BALCONY
AC
A C
ACACAC
A C
STORAGE
14A
TRASH &
GARBAGE
EDUCATION
CLASS ROOM
STAIR
HALL
FITNESS
GYM
EDUCATION
TRAINING
MALE
BATH
UTILITY
19FEMALE
LOCKER
FEMALE
BATH
EMPLOYEE
LOUNGE
1A
OFFICE
6B
EDUCATION
OFFICE
STAIR
HALL
LIBRARY
6A
DRESSING
ROOM
3B
SWIMMING
POOL ROOM
SERVICE
ROOM
3C
POOL
DRESSING
ROOM
3A
BATH
1B
ELEVATOR
CORRIDOR
C0CE
OFFICE
16A
HAC
16B
PIPE
CHASE
19A
CORRIDOR
C0CW
MAILROOM
PATIENT EFFECTS
TELE.
EQUIP.
11B
CLOS.
9A
F.A.
EQUIP.
AUTO
VALET
11A
PROCESSING
11E
OFFICE
CART
STORAGE
8A
PATIENT
EFFECTS
EFFECTS
STORAGE
STAIR
11C
MECH
11D
UNIFORM
DROP
11A
ENTRY
11F
CLOSET
14B
WOMENS
TOILET
UTILITY
HALL
7A
VESTIBULE
13A
UTILITY
13B
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:4 :4
P
M
48-AS100
BASEMENT FLOOR - OVERALL
PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM, BW
16305
03/30/2022
N
0 8' 16'4'1/8" = 1'-0"1
BASEMENT FLOOR - OVERALL PLAN
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
ROOMS.
MULTI-
PURPOSE
FAX/
PRINTER
148A
OFFICE
NURSE'S
STATION
MEDS
147A
PATIENT
DINING
KITCHEN
DAYROOM
LAUNDRY
MALE/PATIENT
1 BED
EXERCISE
ROOM
1 BED
CLC
OFFICE
CLC
OFFICE
FILEROOM
1 BED
TOILET
STAIR
HALL
1 BED
1 BED
4 BED
1 BED
1 BED
PACT PT
TUB
ROOM
SHOWER
MALE
INTAKE
1 BED
2 BED
PURPOSE
PIPE CHASE
109A
PIPE CHASE
110A
CORRIDOR
C1W
STOR/MAIL
101A
1 BED
LOBBY
PIPE
CHASE
127A
ELEVATOR
149B
148B
CORRIDOR
C1C
HAC
STORAGE
KITCHEN
124A
TUB
ROOM
CORRIDOR
C1E
STAIR
HALL
PIPE CHASE
141A
PIPE CHASE
140A
SHOWER
1 BED
WHEELCHAIR
STORAGE
COAT
ROOM
4 BED
PIPE CHASE
109A
2 BED
1 BED
106B
DINING
1 BED
109B
149A
STAIR
124C
2 BED
106C
1 BED
106A
DN
DN
TELECOM
ROOM
48-AS110
'-1
/4
7' -8
5'
-0
122A
OFFICE
122B
MED ROOM
2B
E X
IS
T
12'-0 1/4"
TELECOM
ROOM
122A
OFFICE
2'-6" 4'-4"
2B 122B
MED ROOM
E X
IS
T
B3 B3bs
B3 B3
IN-04.01
IN-04.01
IN-03.01
5'-1"
TELECOM
ROOM
OFFICE
MED ROOM
AFF8'-0"
AFF8'-0"
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:4 :0
P
M
48-AS110
FIRST FLOOR PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM, BMW
16305
03/30/2022
1/8" = 1'-0"
FIRST FLOOR - OVERALL PLAN
0 8' 16'4'
1/4" = 1'-0"
ENLARGED FLOOR PLAN
0 4' 8'2'
1/4" = 1'-0"2
DEMOLITION PLAN
0 4' 8'2'
1/4" = 1'-0"
REFLECTED CEILING PLAN
0 4' 8'2'
DE1
RC1
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
DE2 REMOVE AND SALVAGE DOOR AND PREPARE OPENING TO
ACCOMMODATE PLAN. SEE FLOOR PLAN AND DOOR SCHEDULE
DE3 REMOVE WALL PARTITION IN ITS ENTIRETY.
DE4 CAREFULLY REMOVE AND SALVAGE EXISTING ACT CEILING SYASTEM AS
REQUIRED FOR NEW CONSTRUCTION.
DE19 REMOVE EXISTING VCT FLOORING TO THE EXTENTS SHOWN. PREPARE
FOR INSTALLATION OF NEW FLOORING.
DE30 REMOVE SINK AND ASSOCIATED PLUMBING, SEE MECHANICAL
DE31 PREPARE WINDOW FOR SECURITY INFILL. REMOVE WINDOW SILL
DE32 PREPARE WALL PARTITION FOR SECURITY UPGRADE. REMOVE GYP BD
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
FL6 FINISH NEW WALLS TO MATCH EXISTING WALLS THIS AREA
FL13 DRYWALL PENETRATION BARRIER MESH
FL15 PROVIDE BLACK OUT FILM AT EXISTING WINDOW. NOTED WINDOW SIZE IS
APPROXIMATE. PROVIDE METAL SECURITY SCREEN AT EXTERIOR
WINDOW. INFILL INTERIOR OF WINDOW WITH METAL STUD PARTITION.
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
FL21 OVERHEAD LEAK DIVERTER, SEE PLUMBING.
FL22 LEAK PREVENTION BARRIER WATERPROOFING DETAIL AT EXISTING
PARTITION. SEE AS601.
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
RC3 ACT SYSTEM AND 2X4 LIGHT FIXTURE, MATCH EXIST ADJACENT CEILING.
SEE ELECTRICAL
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
N
N
N
N
DE3
DE4
FL6
FL3
FL20
FL1
FL3
DE19
FL21
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
ROOMS.
DE4
DE2
DE2
FL3
DE3
DE1
FL6
FL15
FL13
FL13
FL13
DE19
RC2
DE30
DE31DE32
RC3
RC3
PSM
NURSE
STUDENT
OFFICE
SECRETARY
STATION
LOBBY
BATHROOM
243A
FEMALE
TOILET
STORAGE
STAIR
HALL
STAIR
HALL
STORAGE
MALE
TOILET
STAIR
CONFERENCE
ROOM
TELEHEALTH
COORD
INFECTION
CONTROL
OFFICE
EMPTY
BIO-MED
STORAGE
226A CLC PROVIDER
OFFICE
BIOMED
BIOMED
BIOMED
213A
BIOMED
215B
STAGING
STAGING
TRAINING
OFFICE
207D
OFFICE
STUDENTS
207A
OFFICE
207B
OFFICE
207C
APPLICATIONS
OFFICE
OFFICE
224C
APPLICATIONS
VISN
OFFICE
MULTI-
PURPOSE
APPLICATIONS
EMPTY
OFFICE
OFFICE
237B
TRANSCRIPTION
OFFICE
PIPE CHASE
210A
PIPE CHASE
209A
I.T.
STOR.
DIRECTOR
STORAGE
233A
STORAGE
PIPE CHASE
236A
TOILET
203A
STORE
STORE
212A
BIOMED
PIPE CHASE
235A
OFFICE
OFFICE
232B
OFFICE
230A
OFFICE
232A
OFFICE
OFFICE
231A
OFFICE
HAC
CORRIDOR
C2W
CORRIDOR
C2C
CORRIDOR
C2E
CORRIDOR
C2N
STUDENTS
201B
TELECOM
ROOM
48-AS120
9'-2"
6' -0
TELECOM
ROOM
2'-11 1/2" 2'-6" 3'-8 1/2"
TELECOM
ROOM
TELECOM
ROOM
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:4 :0
P
M
48-AS120
SECOND FLOOR PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM, BMW
16305
03/30/2022
1/8" = 1'-0"
SECOND FLOOR - OVERALL PLAN
0 8' 16'4'
1/4" = 1'-0"
ENLARGED FLOOR PLAN
0 4' 8'2'
0 4' 8'2'
0 4' 8'2'
1/4" = 1'-0"
DEMOLITION PLAN
1/4" = 1'-0"
REFLECTED CEILING PLAN
RC1
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
DE2 REMOVE AND SALVAGE DOOR AND PREPARE OPENING TO
ACCOMMODATE PLAN. SEE FLOOR PLAN AND DOOR SCHEDULE
DE3 REMOVE WALL PARTITION IN ITS ENTIRETY.
DE4 CAREFULLY REMOVE AND SALVAGE EXISTING ACT CEILING SYASTEM AS
REQUIRED FOR NEW CONSTRUCTION.
DE19 REMOVE EXISTING VCT FLOORING TO THE EXTENTS SHOWN. PREPARE
FOR INSTALLATION OF NEW FLOORING.
DE30 REMOVE SINK AND ASSOCIATED PLUMBING, SEE MECHANICAL
DE31 PREPARE WINDOW FOR SECURITY INFILL. REMOVE WINDOW SILL
DE32 PREPARE WALL PARTITION FOR SECURITY UPGRADE. REMOVE GYP BD
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
FL6 FINISH NEW WALLS TO MATCH EXISTING WALLS THIS AREA
FL13 DRYWALL PENETRATION BARRIER MESH
FL15 PROVIDE BLACK OUT FILM AT EXISTING WINDOW. NOTED WINDOW SIZE IS
APPROXIMATE. PROVIDE METAL SECURITY SCREEN AT EXTERIOR
WINDOW. INFILL INTERIOR OF WINDOW WITH METAL STUD PARTITION.
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
FL21 OVERHEAD LEAK DIVERTER, SEE PLUMBING.
FL22 LEAK PREVENTION BARRIER WATERPROOFING DETAIL AT EXISTING
PARTITION. SEE AS601.
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
RC3 ACT SYSTEM AND 2X4 LIGHT FIXTURE, MATCH EXIST ADJACENT CEILING.
SEE ELECTRICAL
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
N
N
N
N
FL1
FL20
FL22FL3
FL3
FL3
FL3
DE1
DE1
DE1
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
ROOMS.
RC2
EXISTING MISC. EQUIPMENT
EXISTING TANK
EXISTING RAISED CONCRETE PAD
E .C
W
E .H
W
EXISTING MAIN BUILDING
DOMESTIC WATER SERVICE
E .H
W R
C
E.STM
EXISTING
CONDENSATE
PUMPS
2"CW
2"HW
3"MPS
HX-1-48
HX-2-48 (BELOW)
1"HWRC
11_
"CND
E.CND
JOHNSON CONTROL
PANEL FED FROM
48 ECB-1 CKT. 32
PRV
NOTE: HOT WATER
GEN. PROJECT
COMPLETED AND
DWG ENTERED 4-2-15
C O
F F
E E
3C
ROOM
SERVICE
POOL
SWIMMING
3A
LOCKER
3B
LOCKER
PIPE CHASE
STAIR
OFFICE
LOCKER
FEMALE
OFFICE
9A
CLOSET
FA
C0CE
CORRIDOR
MAILROOM
11C
STAIR
11D
MECH
11A
DROP
UNIFORM
STORAGE
EFFECTS
19A
CHASE
PIPE
BATH
MALE
TRAINING AREA
EDUCATION
GYM
FITNESS
16B
HAC
16A
OFFICE
UTILITY
CLASSROOM
EDUCATION
STAIR8A
STORAGE
CART
11B
PHN
C0CW
CORRIDOR
11E
PROCESSING
11A
DROP
UNIFORM
11F
ENTRY
14A
STORAGE
14B
CLOSET
6A
LIBRARY
OFFICE
EDUCATION
6B
OFFICE
ELEVATOR
ELEVATOR
1A
LOUNGE
EMPLOYEE
TOILET
WOMENS
1B
TOILET
7A
UTILITY
13A
VESTIBULE
13B
UTILITY
AC
A C
ACACAC
A C
RAD
R A
D
RADRAD
R A
D R
A D
RADCONVECTOR
CONVECTOR
CONVECTOR
C O
N V
E C
T O
R
PIPE
INSUL
VAC
MEDAIR
OXY
CLIMATE
CONTROL
UNIT
14'-4"
LIMITS OF DATA CABLING DEMOLITION
12"x2"
E
12"x2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:1
P
M
48-TD100
BASEMENT FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 8' 16'4'1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
B48-1
EC&R SAFETY
LAST UPDATED: 12/13/18
6∅
6∅
12x8
EXISTING EXHAUST
TO FAN IN ATTIC
800 CFM FAN
NEW EXHAUST DUCT
EXISTING
RETURN
EXISTING
40x12
12x9 x
20x10 x
12x1010x8 x
10x86x6
S2
S1
S1
S2
S3
S1
T
R1
EXTEND EXISTING 40X12 DUCT
TU-1
TU-2
2 2
4 BED
2 BED
109B
1 BED
INTAKE
106B
1 BED
109A
CHASE
PIPE
101A
STOR.
MALE
SHOWER
PT
PACT
C1W
CORRIDOR
HAC
1 BED
2 BED
1 BED
1 BED120
BATH
STAIR112
ROOM
TUB
1 BED
1 BED
1 BED
4 BED
1 BED
ROOM
DINING
OFFICE 100
LOBBY
PURPOSE
MULTI
OFFICE
148A
FAX
STATION
NURSEE01
ELEVATOR
HAC
FILEROOM
C1C
CORRIDOR
127A
CHASE
PIPE
124A
KITCHEN
STORAGE
OFFICE
CLC
OFFICE
CLC
STOR
STAIR
147A
MED
C1E
CORRIDOR
1 BED
1 BED
ROOM
EXERCISE
1 BED
COATS
SHOWER
LAUNDRY
DAYROOM
KITCHEN
DINING
124C
STAIR
106C
2 BED
106A
1 BED
E02
ELEVATOR
109B
106B
104 103 102
101A
101 100
9A
8B
9B
148A
109A
110A
113111
C1W
C1C
119 120 121
124A
127A
128 129 130 131
C1E
140A
141A
147A
124C
106C
106A
101A
DN
DN
B48-1
EC&R SAFETY
LAST UPDATED: 12/13/18
6∅
6∅
12x8
EXISTING EXHAUST
TO FAN IN ATTIC
800 CFM FAN
NEW EXHAUST DUCT
EXISTING
RETURN
EXISTING
40x12
12x9 x
20x10 x
12x1010x8 x
10x86x6
S2
S1
S1
S2
S3
S1
T
R1
EXTEND EXISTING 40X12 DUCT
TU-1
TU-2
2 2
4 BED
2 BED
109B
1 BED
INTAKE
106B
1 BED
109A
CHASE
PIPE
101A
STOR.
MALE
SHOWER
PT
PACT
C1W
CORRIDOR
HAC
1 BED
2 BED
1 BED
1 BED120
BATH
STAIR112
ROOM
TUB
1 BED
1 BED
1 BED
4 BED
1 BED
ROOM
DINING
OFFICE 100
LOBBY
PURPOSE
MULTI
OFFICE
148A
FAX
STATION
NURSEE01
ELEVATOR
HAC
FILEROOM
C1C
CORRIDOR
127A
CHASE
PIPE
124A
KITCHEN
STORAGE
OFFICE
CLC
OFFICE
CLC
STOR
STAIR
147A
MED
C1E
CORRIDOR
1 BED
1 BED
ROOM
EXERCISE
1 BED
COATS
SHOWER
LAUNDRY
DAYROOM
KITCHEN
DINING
124C
STAIR
106C
2 BED
106A
1 BED
E02
ELEVATOR
109B
106B
104 103 102
101A
101 100
9A
8B
9B
148A
109A
110A
113111
C1W
C1C
119 120 121
124A
127A
128 129 130 131
C1E
140A
141A
147A
124C
106C
106A
101A
DN
DN
C
LIMITS OF DATA CABLING DEMOLITION
48-TD110
E
E
E
E
E
E
E
E
12"x2"
"x
2"
"x 2"
12"x2"
"x
2"
"x 2"
R
PP
SP
E
R
TW E
E
DATA RACK
D
E
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:2
P
M
48-TD110
FIRST FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 8' 16'4' 1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOM - DEMOLITION
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
2. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.
EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING
COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.
NOT TO SCALE
TELECOM DEMO - ENLARGED PLAN - EXIST TR 123
N
0 8' 16'4'
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE
RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT.
1. ROOM 123
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 240
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
207C
OFFICE
207B
OFFICE
207A
OFFICE
207D
OFFICE
TRAINING
STAGING209
STAGING
209A
CHASE
PIPE
MALE
C2W
CORR
CONFERENCE
NURSE
PSM
STORAGE
STOR
BIOMED
213A
BIOMED
BIOMED
BIOMED
215B
BIOMED
STAIR
STOR.
I.T.
COORD.
TELEHEALTH
CONTROL
INFECTION
OFFICE
OFFICE
OI&T
OFFICE
VISN
243A
BATH 243
PURPOSE
MULTI
C2C
CORRIDOR
226A
STORAGE
BIO-MED
OFFICE
OFFICE
224C
OFFICE
OFFICE
DIRECTOR
STAIR
OFFICE
C2N
CORRIDOR
OFFICE
CLC PROVIDER
SCHEDULING
HAC
STAIR
233A
STOR
STORAGE
STOR
C2E
CORR
FEMALE
212A
STOR
OFFICE
ADMIN
OFFICE
230A
OFFICE
232A
OFFICE
232B
OFFICE
OFFICE
231A
OFFICE
ELEVATOR
ELEVATOR
LOBBY
201A
OFFICE
OI&T
STORAGE
OI&T SEC.
OFFICE
RECEPTION
238B
OFFICE
238A
OFFICE
OFFICE
238C
CONFERENCE
VBA
239A
OFFICE
239B
OFFICE
239C
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
48-TD120
LIMITS OF DATA CABLING DEMOLITION
2D
3D/2V
3D/2V
3D/2V
3D/2V
E
E
EE
E
E
E
E
E
E
T T
T
2D
6D
2D/2V 2D/2V
2D/2V2D/2V
2D/2V 2V
2D/2V
2D/2V 2D/2V
2D/2V
1D/2V
2D/2V
3D/2V
4D
4D 2D/2V
2D/2V 4D
4D2D
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
3D/1V
4D 3D/1V
3D/1V
E
E
P 4D
P 1D
P 1D
P
1DE
E E
E
E
EE
E
E
E
E E
E
E
E E
E E E E
E
E
E E
EE
E
E
E
E
E
E
E
E
E E
E
E E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
WAP
WAP
WAP
WAP
E
WAP
WAP
WAP
WAP
E
WAP
WAP
WAP
WAP
WAP
E
G
WAP
E
2D/2V
2D/2V
2D/2V
2D/2V 2D/2V 2D/2V
5D/1V
2D/2V
2D4D 4D
4D 4D 4D2D/2V
4D4D 3D/1V
2D/2V
2D/2V2D/2V 3D
3D
4D
1D/2V
2D 2D/2V
2D
WAP
E
E
WAP
WAP
E
E
WAP
E
WAP
WAP
E
WAP
E
E E
E
E
E
E
E E E
E E E E
E E
E
E
E
E
E
E
E E
E
EE
E
E
2D/2V
E
2D/2V E
E
12"x2"12"x2"
E
EE
E
E
E
E
E
"x
2"
"x
2"
"x 2"
WAP
E
DR
TW
SP
E
FB
PP
R
D
E
DATA RACK
R
4D
4D
E
E
E
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:2
P
M
48-TD120
SECOND FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 8' 16'4'1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOM - DEMOLITION
1/4" = 1'-0"
TELECOM DEMO - ENLARGED PLAN - EXIST TR 221
N
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
2. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.
EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING
COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE
RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT.
1. ROOM 221
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 295
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
ATTIC
PENTHOUSE
STAIR
A02
BUILDING 48 - ATTIC
E E
E
E
E
E
3D
WAP
WAP
WAP
WAP
WAP
WAP
E
LIMITS OF DATA CABLING DEMOLITION
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:2
P
M
48-TD130
ATTIC FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
1/8" = 1'-0"
ATTIC FLOOR PLAN - ELECTRICAL - DEMOLITION
AC
A C
ACACAC
A C
STORAGE
14A
TRASH &
GARBAGE
EDUCATION
CLASS ROOM
STAIR
HALL
FITNESS
GYM
EDUCATION
TRAINING
MALE
BATH
UTILITY
19FEMALE
LOCKER
FEMALE
BATH
EMPLOYEE
LOUNGE
1A
OFFICE
6B
EDUCATION
OFFICE
STAIR
HALL
LIBRARY
6A
DRESSING
ROOM
3B
SWIMMING
POOL ROOM
SERVICE
ROOM
3C
POOL
DRESSING
ROOM
3A
BATH
1B
ELEVATOR
CORRIDOR
C0CE
OFFICE
16A
HAC
16B
PIPE
CHASE
19A
CORRIDOR
C0CW
MAILROOM
PATIENT EFFECTS
TELE.
EQUIP.
11B
CLOS.
9A
F.A.
EQUIP.
AUTO
VALET
11A
PROCESSING
11E
OFFICE
CART
STORAGE
8A
PATIENT
EFFECTS
EFFECTS
STORAGE
STAIR
11C
MECH
11D
UNIFORM
DROP
11A
ENTRY
11F
CLOSET
14B
WOMENS
TOILET
UTILITY
HALL
7A
VESTIBULE
13A
UTILITY
13B
14'-4"
E
4"
"x
2"
"x
2"
12"x2"
"x
2"
E
C4 126"
12"x2"
ENTRY
POINT FOR
FIBER
12"x2" 12"x2"
4"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:2
P
M
48-TN100
BASEMENT FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 8' 16'4'1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
2. PROVIDE JUNCTION BOX TO CONNECT EXISTING FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO
THE NEW TELECOM ROOM.
EC&R SAFETY
LAST UPDATED: 12/13/18
4 BED
2 BED
109B
1 BED
INTAKE
106B
1 BED
109A
CHASE
PIPE
101A
STOR.
MALE
SHOWER
PT
PACT
C1W
CORRIDOR
HAC
1 BED
2 BED
1 BED
1 BED120
BATH
STAIR112
ROOM
TUB
1 BED
1 BED
1 BED
4 BED
1 BED
ROOM
DINING
OFFICE 100
LOBBY
PURPOSE
MULTI
OFFICE
148A
FAX
STATION
NURSEE01
ELEVATOR
HAC
FILEROOM
C1C
CORRIDOR
127A
CHASE
PIPE
124A
KITCHEN
STORAGE
OFFICE
CLC
OFFICE
CLC
STOR
STAIR
147A
MED
C1E
CORRIDOR
1 BED
1 BED
ROOM
EXERCISE
1 BED
COATS
SHOWER
LAUNDRY
DAYROOM
KITCHEN
DINING
124C
STAIR
106C
2 BED
106A
1 BED
E02
ELEVATOR
109B
106B
104 103 102
101A
101 100
9A
8B
9B
148A
109A
110A
113111
C1W
C1C
119 120 121
124A
127A
128 129 130 131
C1E
140A
141A
147A
124C
106C
106A
101A
HAC
MULTI-
PURPOSE
FAX/
PRINTER
148A
OFFICE
NURSE'S
STATION
MEDS
147A
PATIENT
DINING
KITCHEN
DAYROOM
LAUNDRY
MALE/PATIENT
1 BED
EXERCISE
ROOM
1 BED
CLC
OFFICE
CLC
OFFICE
FILEROOM
1 BED
TOILET
STAIR
HALL
1 BED
1 BED
4 BED
1 BED
1 BED
PACT PT
TUB
ROOM
SHOWER
MALE
INTAKE
1 BED
2 BED
PURPOSE
PIPE CHASE
109A
PIPE CHASE
110A
CORRIDOR
C1W
STOR/MAIL
101A
1 BED
LOBBY
PIPE
CHASE
127A
ELEVATOR
149B
148B
CORRIDOR
C1C
HAC
STORAGE
KITCHEN
124A
TUB
ROOM
CORRIDOR
C1E
STAIR
HALL
PIPE CHASE
141A
PIPE CHASE
140A
SHOWER
1 BED
1 BED
WHEELCHAIR
STORAGE
COAT
ROOM
4 BED
PIPE CHASE
109A
2 BED
1 BED
106B
DINING
1 BED
109B
149A
STAIR
124C
2 BED
106C
1 BED
106A
DN
DN
EXIT DOOR OFF OF
STAIRWELL 131 WILL
BE OUT OF SERVICE
MULTI
B48-1
EC&R SAFETY
LAST UPDATED: 12/13/18
4 BED
2 BED
109B
1 BED
INTAKE
106B
1 BED
109A
CHASE
PIPE
101A
STOR.
MALE
SHOWER
PT
PACT
C1W
CORRIDOR
HAC
1 BED
2 BED
1 BED
1 BED120
BATH
STAIR112
ROOM
TUB
1 BED
1 BED
1 BED
4 BED
1 BED
ROOM
DINING
OFFICE 100
LOBBY
PURPOSE
MULTI
OFFICE
148A
FAX
STATION
NURSEE01
ELEVATOR
HAC
FILEROOM
C1C
CORRIDOR
127A
CHASE
PIPE
124A
KITCHEN
STORAGE
OFFICE
CLC
OFFICE
CLC
STOR
STAIR
147A
MED
C1E
CORRIDOR
1 BED
1 BED
ROOM
EXERCISE
1 BED
COATS
SHOWER
LAUNDRY
DAYROOM
KITCHEN
DINING
124C
STAIR
106C
2 BED
106A
1 BED
E02
ELEVATOR
109B
106B
104 103 102
101A
101 100
9A
8B
9B
148A
109A
110A
113111
C1W
C1C
119 120 121
124A
127A
128 129 130 131
C1E
140A
141A
147A
124C
106C
106A
101A
HAC
MULTI-
PURPOSE
FAX/
PRINTER
148A
OFFICE
NURSE'S
STATION
MEDS
147A
PATIENT
DINING
KITCHEN
DAYROOM
LAUNDRY
MALE/PATIENT
1 BED
EXERCISE
ROOM
1 BED
CLC
OFFICE
CLC
OFFICE
FILEROOM
1 BED
TOILET
STAIR
HALL
1 BED
1 BED
4 BED
1 BED
1 BED
PACT PT
TUB
ROOM
SHOWER
MALE
INTAKE
1 BED
2 BED
PURPOSE
PIPE CHASE
109A
PIPE CHASE
110A
CORRIDOR
C1W
STOR/MAIL
101A
1 BED
LOBBY
PIPE
CHASE
127A
ELEVATOR
149B
148B
CORRIDOR
C1C
HAC
STORAGE
KITCHEN
124A
TUB
ROOM
CORRIDOR
C1E
STAIR
HALL
PIPE CHASE
141A
PIPE CHASE
140A
SHOWER
1 BED
1 BED
WHEELCHAIR
STORAGE
COAT
ROOM
4 BED
PIPE CHASE
109A
2 BED
1 BED
106B
DINING
1 BED
109B
149A
STAIR
124C
2 BED
106C
1 BED
106A
DN
DN
EXIT DOOR OFF OF
STAIRWELL 131 WILL
BE OUT OF SERVICE
TELECOM ROOM
48-TN400
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 123
C4 126"
E
"x
2"
"x
2"
12"x2"
"x
2"
"x
2"
12"x2"
E
E
E
E
E
E
E
12"x2"
F2
12" LADDER
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:2
P
M
48-TN110
FIRST FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 8' 16'4'1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOMMUNICATIONS
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
PSM
NURSE
STUDENT
OFFICE
SECRETARY
STATION
LOBBY
BATHROOM
243A
FEMALE
TOILET
STORAGE
STAIR
HALL
STAIR
HALL
STORAGE
MALE
TOILET
STAIR
CONFERENCE
ROOM
TELEHEALTH
COORD
INFECTION
CONTROL
OFFICE
EMPTY
BIO-MED
STORAGE
226A CLC PROVIDER
OFFICE
BIOMED
BIOMED
BIOMED
213A
BIOMED
215B
STAGING
STAGING
TRAINING
OFFICE
207D
OFFICE
STUDENTS
207A
OFFICE
207B
OFFICE
207C
APPLICATIONS
OFFICE
OFFICE
224C
APPLICATIONS
VISN
OFFICE
MULTI-
PURPOSE
APPLICATIONS
EMPTY
OFFICE
OFFICE
237B
TRANSCRIPTION
OFFICE
PIPE CHASE
210A
PIPE CHASE
209A
I.T.
STOR.
DIRECTOR
STORAGE
233A
STORAGE
PIPE CHASE
236A
TOILET
203A
STORE
STORE
212A
BIOMED
PIPE CHASE
235A
OFFICE
OFFICE
232B
OFFICE
230A
OFFICE
232A
OFFICE
OFFICE
231A
OFFICE
HAC
CORRIDOR
C2W
CORRIDOR
C2C
CORRIDOR
C2E
CORRIDOR
C2N
STUDENTS
201B
TELECOM ROOM
48-TN401
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 221
12"x2" 12"x2"
G
P 4D
P 1D
P 1D
P 1D
2D
3D/2V
3D/2V
3D/2V
3D/2V
E
E
E
E
E
E
E
E
E
T T
T
2D
6D
2D/2V 2D/2V
2D/2V2D/2V
2D/2V 2V
2D/2V
2D/2V 2D/2V
2D/2V
1D/2V
2D/2V
3D/2V
4D
4D 2D/2V
2D/2V 4D
4D2D
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
2D/2V
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
3D/1V
4D 3D/1V 3D/1V
E
WAP
E
E
E
E
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
E
E E
E
E
EE
E
E
E
E E
E
E
E E
E E E E
E
E
E E
EE
E
E
E
E
E
E
E
E
E E
E
E E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
WAP
2D/2V
2D/2V
2D/2V
2D/2V 2D/2V2D/2V
5D/1V
2D/2V
2D4D 4D
4D 4D 4D 2D/2V
4D 4D
3D/1V 2D/2V
2D/2V2D/2V3D
3D
4D
1D/2V
2D 2D/2V
2D
WAP
WAP
WAP
WAP
WAP
E
E
E
WAP
E
E
E
E
E
WAP
E E E E
E E
E
E
E
E
E
E
E E
E
E E E
E E
E EE
E
E
E
E
E
CABLE TRAY
2D/2V
E
2D/2V
E
E
C4 126"
E
EE
E
E
"x
2"
"x
2"
"x 2"
E
E
E
"x
2"
"x 2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:2
P
M
48-TN120
SECOND FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 8' 16'4' 1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOMMUNICATIONS
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
ATTIC
PENTHOUSE
STAIR
A02
BUILDING 48 - ATTIC
3D E
WAP WAP
WAP
WAP
WAP
WAP
E E
E
E
E
E
LIMITS OF DATA CABLING REPLACEMENT
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
48-TN130
ATTIC FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
NOT TO SCALE
ATTIC FLOOR PLAN - TELECOMMUNICATIONS
N
0 8' 16'4'
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
EC&R SAFETY
LAST UPDATED: 12/13/18
4 BED
2 BED
109B
1 BED
INTAKE
106B
1 BED
109A
CHASE
PIPE
101A
STOR.
MALE
SHOWER
PT
PACT
C1W
CORRIDOR
HAC
1 BED
2 BED
1 BED
1 BED120
BATH
STAIR112
ROOM
TUB
1 BED
1 BED
1 BED
4 BED
1 BED
ROOM
DINING
OFFICE 100
LOBBY
PURPOSE
MULTI
OFFICE
148A
FAX
STATION
NURSEE01
ELEVATOR
HAC
FILEROOM
C1C
CORRIDOR
127A
CHASE
PIPE
124A
KITCHEN
STORAGE
OFFICE
CLC
OFFICE
CLC
STOR
STAIR
147A
MED
C1E
CORRIDOR
1 BED
1 BED
ROOM
EXERCISE
1 BED
COATS
SHOWER
LAUNDRY
DAYROOM
KITCHEN
DINING
124C
STAIR
106C
2 BED
106A
1 BED
E02
ELEVATOR
109B
106B
104 103 102
101A
101 100
9A
8B
9B
148A
109A
110A
113111
C1W
C1C
119 120 121
124A
127A
128 129 130 131
C1E
140A
141A
147A
124C
106C
106A
101A
HAC
MULTI-
PUR POSE
FAX/
PRINTER
148A
OFFICE
NURSE'S
STATION
MEDS
147A
PATIENT
DINING
KITCHEN
DA YR OOM
LAUN DRY
MALE/ PATI ENT
1 BED
EXERCISE
ROOM
1 BED
CLC
OFFICE
CLC
OFFICE
FILEROOM
1 BED
TOILET
STAIR
HALL
1 BED
1 BED
4 BED
1 BED
1 BED
PACT PT
TUB
ROOM
SHOW ER
MALE
INTAKE
1 BED
2 BED
PUR POSE
PIPE CHASE
109A
PIPE CHASE
110A
CORRI DOR
C1W
STOR/ MAIL
101A
1 BED
LOB BY
PIPE
CHASE
127A
ELE VATOR
149B
148B
CORRI DOR
C1C
HAC
STOR AGE
KITCHEN
124A
TUB
ROOM
CORRI DOR
C1E
STAIR
HALL
PIPE CHASE
141A
PIPE CHASE
140A
SHOW ER
1 BED
1 BED
WHEELC HAIR
STOR AGE
COA T
ROOM
4 BED
PIPE CHASE
109A
2 BED
1 BED
106B
DINING
1 BED
109B
149A
STAIR
124C
2 BED
106C
1 BED
106A
DN
DN
EXIT DOOR OFF OF
STAIRWELL 131 WILL
BE OUT OF SERVICE
MULTI
B48-1
EC&R SAFETY
LAST UPDATED: 12/13/18
4 BED
2 BED
109B
1 BED
INTAKE
106B
1 BED
109A
CHASE
PIPE
101A
STOR.
MALE
SHOWER
PT
PACT
C1W
CORRIDOR
HAC
1 BED
2 BED
1 BED
1 BED120
BATH
STAIR112
ROOM
TUB
1 BED
1 BED
1 BED
4 BED
1 BED
ROOM
DINING
OFFICE 100
LOBBY
PURPOSE
MULTI
OFFICE
148A
FAX
STATION
NURSEE01
ELEVATOR
HAC
FILEROOM
C1C
CORRIDOR
127A
CHASE
PIPE
124A
KITCHEN
STORAGE
OFFICE
CLC
OFFICE
CLC
STOR
STAIR
147A
MED
C1E
CORRIDOR
1 BED
1 BED
ROOM
EXERCISE
1 BED
COATS
SHOWER
LAUNDRY
DAYROOM
KITCHEN
DINING
124C
STAIR
106C
2 BED
106A
1 BED
E02
ELEVATOR
109B
106B
104 103 102
101A
101 100
9A
8B
9B
148A
109A
110A
113111
C1W
C1C
119 120 121
124A
127A
128 129 130 131
C1E
140A
141A
147A
124C
106C
106A
101A
HAC
MULTI-
PUR POSE
FAX/
PRINTER
148A
OFFICE
NURSE'S
STATION
MEDS
147A
PATIENT
DINING
KITCHEN
DA YR OOM
LAUN DRY
MALE/ PATI ENT
1 BED
EXERCISE
ROOM
1 BED
CLC
OFFICE
CLC
OFFICE
FILEROOM
1 BED
TOILET
STAIR
HALL
1 BED
1 BED
4 BED
1 BED
1 BED
PACT PT
TUB
ROOM
SHOW ER
MALE
INTAKE
1 BED
2 BED
PUR POSE
PIPE CHASE
109A
PIPE CHASE
110A
CORRI DOR
C1W
STOR/ MAIL
101A
1 BED
LOB BY
PIPE
CHASE
127A
ELE VATOR
149B
148B
CORRI DOR
C1C
HAC
STOR AGE
KITCHEN
124A
TUB
ROOM
CORRI DOR
C1E
STAIR
HALL
PIPE CHASE
141A
PIPE CHASE
140A
SHOW ER
1 BED
1 BED
WHEELC HAIR
STOR AGE
COA T
ROOM
4 BED
PIPE CHASE
109A
2 BED
1 BED
106B
DINING
1 BED
109B
149A
STAIR
124C
2 BED
106C
1 BED
106A
DN
DN
EXIT DOOR OFF OF
STAIRWELL 131 WILL
BE OUT OF SERVICE
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
48-TN210
FIRST FLOOR PLAN -
TELECOM - CABLE DISTANCE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 30' 60'15' 1" = 30'-0"
FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
STUDE NTS
PSM
NURSE
STUD ENT
OFFICE
SECR ETA RY
STATION
LOB BY
BATHR OOM
243A
FEMALE
TOILET
STOR AGE
STAIR
HALL
STAIR
HALL
STOR AGE
MALE
TOILET
STAIR
CONFERE NCE
ROOM
TELEH EALTH
COORD
INFECTION
CON TR OL
OFFICE
EMP TY
BIO-MED
STOR AGE
226A CLC PROVIDER
OFFICE
BIOMED
BIOMED
BIOMED
213A
BIOMED
215B
STAGING
STAGING
TRAINING
OFFICE
207D
OFFICE
STUDE NTS
207A
OFFICE
207B
OFFICE
207C
APPLI CATI ONS
OFFICE
OFFICE
224C
APPLI CATI ONS
VISN
OFFICE
MULTI-
PUR POSE
APPLI CATI ONS
EMP TY
OFFICE
OFFICE
237B
TRANSCR IPTION
OFFICE
PIPE CHASE
210A
PIPE CHASE
209A
I.T.
STOR.
DIRECTOR
STOR AGE
233A
STOR AGE
PIPE CHASE
236A
TOILET
203A
STORE
STORE
212A
BIOMED
PIPE CHASE
235A
OFFICE
OFFICE
232B
OFFICE
230A
OFFICE
232A
OFFICE
OFFICE
23…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .