201202 - 10878160 Appendix F SCS - Boat Work Bay Rev03.pdf

PDF 263 KB Posted

Attached to
Design/Build Facilities and Waterfront at USCG Station Fort Myers Beach, Fort Myers, FL
Solicitation number
70Z04721RMYERDB
Issued by

View the file

Other files

File Type Posted
Amend_0016_70Z04721RMYERDB_pg2-3.pdf PDF
Amendment 0016_Page 1.pdf PDF
Amendment 0015_Page 1.pdf PDF
Amend_0015_70Z04721RMYERDB_pg2-5.pdf PDF
201202 - 10878160 Appendix F SCS - Boat WASH Bay Rev01.pdf PDF
Amend_0014_70Z04721RMYERDB_pg2-14.pdf PDF
Amendment 0014 Page 1.pdf PDF
70Z04721RMYERDB_Amend_0013.pdf PDF
70Z04721RMYERDB_Amend_0012.pdf PDF
0049-0105 Amendment 0012_Attach_001.pdf PDF
Amendment 0011 Page 1.pdf PDF
Amend_0011_70Z04721RMYERDB_pg2-9.pdf PDF
Visitor Access List 70Z04720RTYBEDB_FtMyers_1100 - FINAL.pdf PDF
Visitors Access List 70Z04720RTYBEDB_FtMyers_0900 - Final.pdf PDF
Amendment 0010 Page 1.pdf PDF
70Z04721MYERDB_Amendment 0009.pdf PDF
Amendment_0008_70Z04721RMYERDB.pdf PDF
Amendment 0007 Page 1.pdf PDF
Amendment 0007_page 2.pdf PDF
DRAFT NEPA EA - Fort Myers (Oct Draft).pdf PDF
Attachment D - Field Surveys (Shore and Waterfront).pdf PDF
Amendment_0006_70Z04721MYERDB.pdf PDF
Attachment F - Building 1 and 2 ACM and Lead.pdf PDF
Attachment B - Survey Field Notes and Data Drawings.pdf PDF
Attachment C- Waterfront Structures Field Investigation Report.pdf PDF
10878160_USCG STA-FMB Site Survey-DWGs 335000017.AB.1.zip ZIP file
Amendment 0005 Page 1.pdf PDF
_USCG 1977 STA-FMB - Compiled Fort Myers Beach USCG Misson Building 1977.pdf PDF
10878160_USCG STA-FMB Site Survey DWGs 335000017.AB.2.zip ZIP file
Amend_0005_70Z04721RMYERDB_pg2-4.pdf PDF
Transmittal - 00025_11-02-20.pdf PDF
Amendment 0004_70Z04721FMYERDB.pdf PDF
Amendment 0003_70Z04721RMYERDB.pdf PDF
Amend_0002_70Z04721RMYERDB_pg2.pdf PDF
Amendment 0002 Page 1.pdf PDF
USCG 2005 STA FMB - Boat Basin Dredge 07-M05032-2005.pdf PDF
USCG_87_WBP (Cutter Boat) ILSP LOGISTICS SUPPORT INFO.pdf PDF
TOA_Fort Myers_10-14-2020.pdf PDF
USCG 2017 STA-FMB - FIRE ALARM DWGS 440P-215403-May15 2017.pdf PDF
70Z04721RMYERDB_Amendment 0001.pdf PDF
USCG 1994 STA -FMB - TOPO survey 1994.pdf PDF
10878160_ USCG STA-FMB Site Survey 335000017.AB 200723cbg-SnS.pdf PDF
Wage_Determination_FL20200211_9-4-2020.pdf PDF
Transmittal - 00025.pdf PDF
USCG 1984 STA-FMB - PIER REPLACEMENT Jan 24 1984.pdf PDF
USCG 2008 STA FMB - 87 foot boat MOORING PIER EXTENSION - 611975-Oct 23 2008.pdf PDF
USCG 1988 STA-FMB - REBUILD BULKHEAD Jun 8 1988.pdf PDF
USCG 1996 STA-FMB - DWG_M0317-S_SH2_ASBESTOS ABATEMENT PLAN July 31 1996.pdf PDF
10878160_USCG STA-FMB Site Survey 335000017.AB.pdf PDF
USCG 2014 STA-FMB - Replace HVAC System USCG Station-6115266-Sept 4 2014.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DB RFP – STATION FORT MYERS REBUILD

U S C G F o r t M y e r s , F l o r i d a |

SPACE CRITERIA SHEET

Multi-Mission Building - Station Update to pages

67, 68 & 69

Fort Myers, Florida Date: 12/02/2020

SPACE NAME Work Bay (Boat Work Bay)

SPACE

TYPE

Marine Maintenance

ACTIVITY Boat Maintenance of Trailerable Boats

ADJACENCIES

ROOM NO.

Min Ceiling Ht. 21’-0” (clear)

Program Area 1,830

Contractor Qty Item Qty Item

Furnished;

Contractor Installed

S-1A Eye Level Hgt Cab S-1C Eye Level Hgt Cab S-1D Eye Level Hgt Cab S-1E Eye Level Hgt Cab S-1F Eye Level Hgt Cab S-3A Bench Level Hgt Cab S-3B Bench Level Hgt Cab S-3C Bench Level Hgt Cab S-3D Bench Level Hgt Cab S-3E Bench Level Hgt Cab S-4 Mobile Utility Cart S-5 Shop Workbench Top S-8 Shop Stool

S-13 Drill Press S-14 Hydraulic Press S-15 Grinder S-16 Large Vice S-17 Pedestal Grinder S-18 Blast Cabinet S-24 Pallet Rack S-27 Flammable Storage Cab S-28 Corrosive Storage Cab S-29 Hazmat Storage Cab S-31 Solvent Cleaner F-8 Recycling Bins

Government Furnished;

Contractor Installed

Finishes Ceiling Open to Structure, painted. Ceiling height: 21’-0” clear to underside of any element. Height to include SPC-LE boat height of 14’-5” (on trailer), 1’ of ground clearance, 5’ clearance to underside of structure, lighting, fire sprinklers, overhead crane, HVAC components, whichever is lower.

Boat Work Bay to be designed with structural elements and other building elements deterring the roosting of birds. Bird netting not allowed.

Floor Provide high reflectance index epoxy coating at concrete floor slab.

Provide grit in floor to prevent slipping. Floor design load 250psf minimum. Slope floor as required to central trench drain (removable grating) that feeds to 24”x48”x24” deep sump. Sump is not connected to the sewer system and must be manually evacuated for offsite disposal.

Walls Shall be CMU or concrete, sealed or painted.

Door 16’H x 16’W clear opening roll-up exterior door. Provide (2) 3’W x 7’H egress doors with vision panels. Provide (1) door located near/adjacent to roll-up door and other at the opposite end of bay. Doors/frames to be FRP. Doors to have SS kickplates extending from bottom to 24"AFF (min.).

Sound Ceiling

Attenuation Floor

Walls

Security

Multi-Mission Building - Station Update to pages

67, 68 & 69

Fort Myers, Florida Date: 12/02/2020

SPACE NAME Work Bay (Boat Work Bay)

SPACE

TYPE

Marine Maintenance

ACTIVITY Boat Maintenance of Trailerable Boats

ADJACENCIES

ROOM NO.

Min Ceiling Ht. 21’-0” (clear)

Program Area 1,830

Utility Mech.

Rollup door switch shutting off HVAC when the door is open. No refrigerant air conditioning in the boat maintenance bay. Circulation fans to be provided to control stratified air.

Services

Plumb.

Provide four compressed air tool drops in bays, two drops on the exterior of the boat bays adjacent hose bibbs including valve, filter, and accessories, two compressed air hose reels, two hose bibbs on exterior walls, and one hose bibb within the boat bay.

Elect.

Power: Provide one receptacle for every 25 ft of wall space at the floor line. When 25 ft or less of wall at the floor line exists in a room, provide a minimum of two receptacles. Provide receptacle within 25 ft of mechanical equipment on the interior and exterior of buildings. Provide dedicated circuits for equipment in special use room.

Lighting: Suspended linear direct LED luminaire / indirect LED luminaire.

Provide 50 foot-candles (fc) at 2’-6” AFF. Provide manual controls with bi-level dimming capabilities to independently control general lighting, manual on with step dimming capability with at least one step to between 30% and 70% of lighting power. General lighting in day lighted areas separately controlled through multilevel photo control, step dimming or continuous dimming to reduce light output when daylight is available, with at least two steps, one to 35% lighting power, and one between 50% and 70% of lighting power. Provide two portable drop down LED luminaires per maintenance bay.

Comm.

Fire Life Safety

Other

Notes:

1.

2.

Multi-Mission Building - Station Fort Myers, Florida Date: 7/22/2020

SPACE NAME Work Bay (Boat Work Bay)

SPACE

TYPE

Marine Maintenance

Program Area 1830

ROOM OUTFITTING PLAN:

Notes:

1. FF+E Indicator: Refer to space data sheet and section 01800.15.0.

2.