Attachment 1e Revised.Additional Drawings Hangar 9 Renovation_6.26.2025.pdf
PDF 6 MB Posted
- Attached to
- Solicitation - Hanger 9 Renovation at the Mike Monroney Aeronautical Center (MMAC), Oklahoma City, OK
- Solicitation number
- 6973GH-25-R-00132
About this file
These architectural renovation drawings detail the comprehensive renovation plans for Hangar 9 at the Mike Monroney Aeronautical Center in Oklahoma City. The multi-level renovation project covers approximately 45,000 square feet across three floors (first, second, and third levels), involving extensive modifications to interior spaces including offices, restrooms, mechanical rooms, corridors, and support areas. The drawings specify demolition and reconstruction work, including new flooring, ceiling systems, lighting, fire suppression, electrical, and plumbing infrastructure across four distinct building sectors.
Key technical elements include replacing existing floor finishes with new vinyl tile and carpet, installing new acoustical ceiling systems, upgrading electrical and lighting systems with LED fixtures, modifying fire alarm and sprinkler systems, and renovating restroom facilities with new fixtures and finishes. The project involves precise architectural detailing for each floor, with specific attention to room layouts, accessibility requirements, and integration of mechanical, electrical, and plumbing systems. The renovation is planned to be executed in phases, with careful coordination required to maintain facility operations during construction.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Drawing No. AMP - 400 -lead or pm designed
WORK REQUEST NO.
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
MIKE MONRONEY AERONAUTICAL CENTER − OKLAHOMA CITY, OKLAHOMA
drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2 1:
:2
A
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2 1:
:2
A
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
INDEX OF DRAWINGS
1550021
MATTCV
11.10.2023
G-004
SHT No SHEET NAME REV DATE
0000 - GENERAL
G-001 COVER SHEET 0 01.24.25
G-002 GENERAL PROJECT INFORMATION 0 01.24.25
G-003 GENERAL PROJECT INFORMATION 0 01.24.25
G-004 INDEX OF DRAWINGS 2 06.26.25
G-005 CONTRACTOR HAUL ROUTE AND LAY DOWN AREA 0 01.24.25
G-006 PHASING PLAN 0 01.24.25
0000 - GENERAL: 6
02 - GENERAL
G001 LIFE SAFETY CODE ANALYSIS 0 01.24.25
GI002 LIFE SAFETY OCCUPANT LOAD CALCULATIONS 0 01.24.25
GI110 LIFE SAFETY PLAN LEVEL 1 - COMPOSITE 0 01.24.25
GI120 LIFE SAFETY PLAN LEVEL 2 - COMPOSITE 0 01.24.25
GI130 LIFE SAFETY PLAN LEVEL 3 - COMPOSITE 0 01.24.25
02 - GENERAL: 5
04 - ARCHITECTURAL
AD101 LEVEL 1 COMPOSITE DEMOLITION PLAN - FLOORING 0 01.24.25
AD102 LEVEL 2 COMPOSITE DEMOLITION PLAN - FLOORING 2 06.26.25
AD103 LEVEL 3 COMPOSITE DEMOLITION PLAN - FLOORING 2 06.26.25
AD104 LEVEL 1 COMPOSITE DEMOLITION PLAN - CEILINGS 0 01.24.25
AD105 LEVEL 2 COMPOSITE DEMOLITION PLAN - CEILINGS 2 06.26.25
AD106 LEVEL 3 COMPOSITE DEMOLITION PLAN - CEILINGS 0 01.24.25
A-110 LEVEL 1 - COMPOSITE FLOOR PLAN 2 06.26.25
A-110a LEVEL 1 - SLAB THICKNESS PLAN 1 06.17.25
A-111 LEVEL 1 - SECTORS 1 & 2 0 01.24.25
A-112 LEVEL 1 - SECTORS 3 & 4 0 01.24.25
A-120 LEVEL 2 - COMPOSITE FLOOR PLAN 0 01.24.25
A-121 LEVEL 2 - SECTORS 1 & 2 0 01.24.25
A-122 LEVEL 2 - SECTORS 3 & 4 0 01.24.25
A-130 LEVEL 3 - COMPOSITE FLOOR PLAN 0 01.24.25
A-131 LEVEL 3 - SECTORS 1 & 2 0 01.24.25
A-132 LEVEL 3 - SECTORS 3 & 4 0 01.24.25
A-210 LEVEL 1 - COMPOSITE RCP 0 01.24.25
A-211 LEVEL 1 - SECTORS 1 & 2 RCP 0 01.24.25
A-212 LEVEL 1 - SECTORS 3 & 4 RCP 0 01.24.25
A-220 LEVEL 2 - COMPOSITE RCP 0 01.24.25
A-221 LEVEL 2 - SECTORS 1 & 2 RCP 0 01.24.25
A-222 LEVEL 2 - SECTORS 3 & 4 RCP 2 06.26.25
A-230 LEVEL 3 - COMPOSITE RCP 0 01.24.25
A-231 LEVEL 3 - SECTORS 1 & 2 RCP 0 01.24.25
SHT No SHEET NAME REV DATE
05 - INTERIORS: 19
06 - FIRE PROTECTION
FA001 FIRE ALARM LEGEND AND GENERAL NOTES 2 06.20.25
FA110 FIRE ALARM PLAN LEVEL 1 - HANGAR BAY 0 01.24.25
FA111 FIRE ALARM PLAN LEVEL 1 - SECTORS 1 & 2 1 06.17.25
FA112 FIRE ALARM PLAN LEVEL 1 - SECTORS 3 & 4 0 01.24.25
FA121 FIRE ALARM PLAN LEVEL 2 - SECTORS 1 & 2 0 01.24.25
FA122 FIRE ALARM PLAN LEVEL 2 - SECTORS 3 & 4 2 06.20.25
FA131 FIRE ALARM PLAN LEVEL 3 - SECTORS 1 & 2 0 01.24.25
FA132 FIRE ALARM PLAN LEVEL 3 - SECTORS 3 & 4 0 01.24.25
FA600 TYPICAL FIRE ALARM RISER DIAGRAM 0 01.24.25
FA601 TYPICAL FIRE ALARM INPUT / OUTPUT MATRIX 0 01.24.25
FX001 FIRE SUPPRESSION GENERAL NOTES AND LEGEND 2 06.20.25
FX110 FIRE SUPPRESSION PLAN LEVEL 1 - COMPOSITE 2 06.20.25
FX120 FIRE SUPPRESSION PLAN LEVEL 2 - COMPOSITE 2 06.20.25
FX130 FIRE SUPPRESSION PLAN LEVEL 3 - COMPOSITE 2 06.20.25
06 - FIRE PROTECTION: 14
07 - PLUMBING
P-001 LEGEND AND ABBREVATIONS 1 06.20.25
PD110 PLUMBING DEMO 0 01.24.24
PD120 PLUMBING DEMO 0 01.24.24
PD130 PLUMBING DEMO 0 01.24.24
PD411 ENLARGED PLUMBING DEMOLITION - SECTOR 1 AND 2 0 01.24.24
PD412 ENLARGED PLUMBING DEMOLITION - SECTOR 3 AND 4 0 01.24.24
PD421 ENLARGED PLUMBING DEMOLITION - SECTOR 2 0 01.24.24
PD422 ENLARGED PLUMBING DEMOLITION - SECTOR 3 AND 4 0 01.24.24
PD431 ENLARGED PLUMBING DEMOLITION - SECTOR 1 AND 2 0 01.24.24
PD432 ENLARGED PLUMBING DEMOLITION - SECTOR 3 AND 4 0 01.24.24
P-110 PLUMBING OVERALL 0 01.24.24
P-120 PLUMBING OVERALL 0 01.24.24
P-130 PLUMBING OVERALL 0 01.24.24
P-411 LEVEL 1 - ENLARGED PLUMBING DRAWINGS - SECTOR 1 AND 2 0 01.24.24
P-412 LEVEL 1 - ENLARGED PLUMBING DRAWINGS - SECTOR 3 AND 4 0 01.24.24
P-421 LEVEL 2 - ENLARGED PLUMBING DRAWINGS - SECTOR 1 AND 2 0 01.24.24
P-422 LEVEL 2 - ENLARGED PLUMBING DRAWINGS - SECTOR 3 AND 4 0 01.24.24
P-431 LEVEL 3 - ENLARGED PLUMBING DRAWINGS - SECTOR 1 AND 2 0 01.24.24
P-432 LEVEL 3 - ENLARGED PLUMBING DRAWINGS - SECTOR 3 AND 4 0 01.24.24
P-501 PLUMBING DETAILS 0 01.24.24
P-601 PLUMBING SCHEDULES 1 06.20.25
P-901 DOMESTIC WATER ISOMETRICS - SECTOR 1 AND 2 0 01.24.24
P-902 DOMESTIC WATER ISOMETRICS - SECTOR 3 AND 4 0 01.24.24
P-903 SANITARY AND VENT ISOMETRICS - SECTOR 1 AND 2 0 01.24.24
P-904 SANITARY AND VENT ISOMETRICS - SECTOR 3 AND 4 0 01.24.24
SHT No SHEET NAME REV DATE
07 - PLUMBING: 25
10 - MECHANICAL
M-001 LEGEND AND ABBREVIATIONS 1 06.20.25
M-110 MECHANICAL OVERALL 0 01.24.24
M-111 LEVEL 1 - MECHANICAL PLAN - SECTORS 1 AND 2 1 06.17.25
M-112 LEVEL 1 - MECHANICAL PLAN - SECTORS 3 AND 4 1 06.17.25
M-120 MECHANICAL OVERALL 0 01.24.24
M-121 LEVEL 2 - MECHANICAL PLAN - SECTORS 1 AND 2 1 06.17.25
M-122 LEVEL 2 - MECHANICAL PLAN - SECTORS 3 AND 4 1 06.17.25
M-130 MECHANICAL OVERALL 0 01.24.24
M-131 LEVEL 3 - MECHANICAL PLAN - SECTORS 1 AND 2 1 06.17.25
M-132 LEVEL 3 - MECHANICAL PLAN - SECTORS 3 AND 4 1 06.17.25
M-401 LEVEL 3 - MECHANICAL ENLARGED SECTOR 3 AND 4 0 01.24.24
M-601 MECHANICAL SCHEDULES 0 01.24.24
10 - MECHANICAL: 12
1500 - ELECTRICAL
E-001 LEGEND AND ABBREVIATIONS 1 6/26/25
ED111 LEVEL 1 - LIGHTING DEMOLITION PLANS 1 6/26/25
ED112 LEVEL 1 - LIGHTING DEMOLITION PLANS 0 03/14/25
ED211 LEVEL 2 - LIGHTING DEMOLITION PLANS 0 03/14/25
ED212 LEVEL 2 - LIGHTING DEMOLITION PLANS 1 6/26/25
ED311 LEVEL 3 - LIGHTING DEMOLITION PLANS 0 03/14/25
ED312 LEVEL 3 - LIGHTING DEMOLITION PLANS 0 03/14/25
ED313 LEVEL 3 - DEMOLITION POWER PLAN 0 03/14/25
EL111 LEVEL 1 - LIGHTING PLAN 1 6/26/25
EL112 LEVEL 1 - LIGHTING PLAN 0 03/14/25
EL211 LEVEL 2 - LIGHTING PLAN 0 03/14/25
EL212 LEVEL 2 - LIGHTING PLAN 1 6/26/25
EL311 LEVEL 3 - LIGHTING PLAN 0 03/14/25
EL312 LEVEL 3 - LIGHTING PLAN 0 03/14/25
EP110 ENLARGED POWER PLANS LEVEL 1 0 03/14/25
EP210 ENLARGED POWER PLANS LEVEL 2 0 03/14/25
EP310 ENLARGED POWER PLANS LEVEL 3 0 03/14/25
E-601x ELECTRICAL PARTIAL ONE-LINE & LIGHTING CONTROLS 0 03/14/25
E-602 INVERTER PANEL SCHEDULES 0 03/14/25
E-001XX COVER SHEET 0 03/14/25
E-002 LEGEND AND ABBREVIATIONS 1 6/26/25
ED110 HIGH BAY LIGHTING DEMOLITION LIGHTING PLAN 0 03/14/25
EL110 HIGH BAY LIGHTING PLAN 0 03/14/25
E-501 LIGHTING CONTROL DETAILS 0 03/14/25
E-601 ELEVATIONS & INVERTER PANEL SCHEDULE 0 03/14/25
1500 - ELECTRICAL: 25
Grand total: 158
SHT No SHEET NAME REV DATE
A-232 LEVEL 3 - SECTORS 3 & 4 RCP 0 01.24.25
A-301 BUILDING SECTIONS 1 06.17.25
A-302 BUILDING SECTIONS 0 01.24.25
A-303 BUILDING SECTIONS 0 01.24.25
A-401 ENLARGED PLANS - 104E, 224E 2 06.26.25
A-402 ENLARGED PLANS - 143E 2 06.26.25
A-403 ENLARGED PLANS - 107W, 106W, 115W 2 06.26.25
A-404 ENLARGED PLANS - 215E, 218E 2 06.26.25
A-405 ENLARGED PLANS - 215E, 218E 2 06.26.25
A-406 ENLARGED PLANS - 214W, 215W 2 06.26.25
A-407 ENLARGED PLANS - 305E, 311E, 313E 2 06.26.25
A-408 ENLARGED PLANS - 305E, 311E, 313E 2 06.26.25
A-409 ENLARGED PLANS - 328E 2 06.26.25
A-410 ENLARGED PLANS - 303W, 304W 2 06.26.25
A-411 ENLARGED PLANS - 313W, 315W 2 06.26.25
A-412 ENLARGED PLANS 0 01.24.25
A-413 ENLARGED PLANS 0 01.24.25
A-420 INTERIOR ELEVATIONS 2 06.26.25
A-421 INTERIOR ELEVATIONS 2 06.26.25
A-422 INTERIOR ELEVATIONS 2 06.26.25
A-423 INTERIOR ELEVATIONS 2 06.26.25
A-424 INTERIOR ELEVATIONS 2 06.26.25
A-425 INTERIOR ELEVATIONS 2 06.26.25
A-501 DETAILS 0 01.24.25
A-502 DETAILS 2 06.26.25
A-601 PARTITION TYPES 0 01.24.25
A-602 PARTITION TYPES 0 01.24.25
A-603 DOOR SCHEDULE/DETAILS 0 01.24.25
04 - ARCHITECTURAL: 52
05 - INTERIORS
I-111 LEVEL 1 FINISH PLAN - SECTORS 1 & 2 1 06.17.25
I-112 LEVEL 1 FINISH PLAN - SECTORS 3 & 4 1 06.17.25
I-121 LEVEL 2 FINISH PLAN - SECTORS 1 & 2 2 06.26.25
I-122 LEVEL 2 FINISH PLAN - SECTORS 3 & 4 2 06.26.25
I-131 LEVEL 3 FINISH PLAN - SECTORS 1 & 2 2 06.26.25
I-132 LEVEL 3 FINISH PLAN - SECTORS 3 & 4 1 06.17.25
IG531 SIGNAGE DETAILS 0 01.24.25
I-400 ENLARGED PLANS & ELEVATIONS 0 01.24.25
I-401 ENLARGED PLANS & ELEVATIONS 0 01.24.25
I-402 ENLARGED PLANS & ELEVATIONS 0 01.24.25
I-403 ENLARGED PLANS & ELEVATIONS 0 01.24.25
I-404 ENLARGED PLANS & ELEVATIONS 0 01.24.25
I-405 ENLARGED PLANS & ELEVATIONS 0 01.24.25
I-406 ENLARGED PLANS & ELEVATIONS 0 01.24.25
I-407 ENLARGED PLANS & ELEVATIONS 0 01.24.25
I-408 MILLWORK DETAILS 0 01.24.25
IN601 ROOM FINISH SCHEDULE - LEVELS 1 & 2 2 06.26.25
IN602 ROOM FINISH SCHEDULE - LEVEL 3 2 06.26.25
IN603 MATERIALS & FINISH LEGEND 1 06.17.25
1 1
No. Date Description Issued by
Issued to
0 01.24.25 100% DESIGN SUBMITTAL TV FAA
1 06.17.25 AMENDMENT 1 TV FAA
2 06.26.25 AMENDMENT 2 TV FAA
L
J
J
G
G
F
F
E
E
D
D
C
C
B
B
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
A-401
A-404
A-406
MEN
214W
WOMEN
215W
WOMEN
215E
MEN
218E
UNISEX
224E
ELEV.
200QE
STAIR
201E
ELEV.
200JE
STAIR
207E
P A
R K
IN
G
S
ID
E
T A
R M
A C
S
ID
E
ELEV.
200DW
MECHANICAL
231W
WOMEN
202W
MEN
203AW
STORAGE
203BW
BREAK ROOM
204W
OPEN OFFICE
205W
STAIR
200CW
STAIR
200HW
CORRIDOR
200FW
ELEV.
200GW
JANITOR
217W
ELEC.
218W
CORR.
216W
ELEC.
226W
STAIR
225W
ELEC.
216E
MECHANICAL
217E
OPEN OFFICE
222E
CORRIDOR
212E
OFFICE
222AE
CORRIDOR
218AE
MEN
223E
MECHANICAL
227E
WOMEN
225E
CORRIDOR
226E
BREAK ROOM
229E
CONFERENCE ROOM
233EE
OFFICE
233DE
OFFICE
233CE
OFFICE
233BE
OFFICE
233AE
OPEN OFFICE
233E
FILE STORAGE
230E
OFFICE
210W
OFFICE
208W
OPEN OFFICE
229W
OFFICE
227AW
CONFERENCE
230W
OFFICE
211W
OPEN OFFICE
221W
OFFICE
220W
OFFICE
219W
OFFICE
228E
DEMO LEGEND - FLOORING
EXISTING FLOORING TO
BE REMOVED
EXISTING FLOORING TO
REMAIN
EXISTING TO BE
REMOVED
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2
:2
:3
P M
A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2
:2
:3
P M
A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
LEVEL 2 COMPOSITE DEMOLITION PLAN - FLOORING
1550021
MATTCV
11.10.2023
AD102
N
SECTOR 2
SECTOR 1 SECTOR 3
SECTOR 4
HIGH BAY
1" = 20'-0"1
LEVEL 2 - COMPOSITE DEMO - FLOORING
0 10' 20' 40'
14 THE CONTRACTOR SHALL NOT BE RESPONSIBLE FOR HAZARDOUS MATERIAL MITIGATION.
SHOULD ANY BE DISCOVERED IT SHOULD BE BROUGHT TO THE ATTENTION OF THE FAA
AND THE ARCHITECT IMMEDIATELY AND BE HANDLED UNDER A SEPERATE CONTRACT.
13 EXISTING CEILING SYSTEMS (ACOUSTICAL CEILING PANELS AND GRID) ARE TO BE
DEMOLISHED IN EXISTING AREAS U.N.O. COORDINATE WITH M.E.P. FOR ALL CEILING ITEMS
TO BE REPLACED OR RE-USED WITHIN SCOPE OF WORK.
12 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE
INSTALLATION OF NEW CONSTRUCTION AND AS NECESSARY TO FULFILL THE PURPOSE
AND INTENT OF THE FINISH WORK, WHETHER OR NOT IT IS SPECIFICALLY SHOWN OR
NOTED IN THESE DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS
SLATED FOR DEMOLITION. THIS INCLUDES ANY ADDITIONAL CONCRETE SLAB CUTTING AND
TRENCHING FOR NEW PLUMBING.
11 PROTECT FROM DEMOLITION AND RECONSTRUCTION DEBRIS, ALL "EXISTING TO REMAIN"
FIXTURES, FINISHES, EQUIPMENT, ETC. REQUIRED TO REMAIN IN PLACE DURING
CONSTRUCTION.
10 ALL DEMOLITION MATERIAL IS TO BE LEGALLY DISPOSED OF IN ACCORDANCE WITH STATE, LOCAL AND FEDERAL LAW.
9 COORDINATE CEILING REMOVAL WITH ALL TRADES AS REQUIRED.
8 COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE ALL WORK WHICH
WILL AFFECT THE TENANTS ON ADJACENT FLOORS OR SPACES.
7 ANY DISCREPANCY FOUND ON DRAWINGS AND FIELD CONDITION SHALL BE BROUGHT TO
THE ATTENTION OF THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO
PROCEEDING WITH THE WORK IN QUESTION.
6 PROMPTLY REPAIR DAMAGES CAUSED TO ADJACENT AREAS BY DEMOLITION OPERATION
AT NO COST.
5 EXISTING ELECTRIC AND TELECOMMUNICATIONS OUTLETS INTERFERING WITH NEW WORK
SHALL BE REMOVED OR RELOCATED.
4 THE CONTRACTOR SHALL KEEP DUST TO A MINIMUM BEFORE AND DURING REMOVAL FROM
THE PREMISES. WHEN CUTTING INTO CONCRETE OR MASONRY TYPE MATERIAL,
CONTRACTOR MUST COMPLY WITH OSHA SILICA STD. 1926.1153, RESPIRABLE CRYSTALLINE
SILICA, TABLE 1.
3 THE CONTRACTOR SHALL REMOVE ALL WORK AS INDICATED ON THE CONSTRUCTION
DRAWING.
2 CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE
FOR ALL ITEMS SALVAGED BUT NOT REUSED.
1 DEMOLITION AND REMOVAL WORK SHALL BE DONE WITH DUE CARE, INCLUDING BRACING,
ETC. PERFORM PATCHING AND RESTORATION AS REQUIRED TO REMEDY AND RESTORE
SUCH DAMAGED PARTS EQUAL TO ADJACENT AREA.
DEMOLITION GENERAL NOTES
WEST - AMOUNT OF FLOORING TO BE REMOVED:
APPROX. 5,529 SQ. FT - V.I.F.
EAST - AMOUNT OF FLOORING TO BE REMOVED:
APPROX. 7,182 SQ. FT - V.I.F.
TOTAL LEVEL 2 ALL TYPES FLOORING REMOVAL:
APPROX. 12,711 SQ. FT - V.I.F.
LEVEL 2 CARPET REMOVAL:
APPROX. 10,536 SQ. FT - V.I.F.
NOTE: IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY ALL QUANTITIES
DEMOLISHED IN FIELD. NUMBERS LISTED ABOVE
ARE THE ARCHITECT'S BEST ESTIMATE BASED
ON OWNER PROVIDED RECORD DRAWINGS.
No. Date Description Issued by
Issued to
0 01.24.25 100% DESIGN SUBMITTAL TV FAA
2 06.26.25 AMENDMENT 2 TV FAA
J
J
G
G
F
F
E
E
D
D
C
C
B
B
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
A-407
A-409
A-410
A-411
A-412
MEN
303W
WOMEN
304W
MEN
313W
WOMEN
315W
MEN
305E
WOMEN
313E
UNISEX
311E
MEN
328E
BREAK ROOM
309W
ELEV.
300GW
CORR.
302W
INDUSTRIAL
323E
STO.
324E
STAIR
301W
ELEV.
300DW
STAIR
327W
STAIR
316W
ELEV.
300QE
STAIR
307E
ELEV.
300JE
STAIR
333E STAIR
320E
P A
R K
IN
G
S
ID
E
T A
R M
A C
S
ID
E
ELEC.
335W
ELEC.
326W
TELE.
325W
ELEC.
319W
MECHANICAL
318W
CORRIDOR
300FW
STORAGE
321W
CORR.
302W
MECHANICAL
331E
ELEC.
330E
OPEN OFFICE
309E
OFFICE
309AE
ELEC.
308E
OFFICE
334W
OFFICE
333W
OFFICE
332W
OPEN OFFICE
330W
OPEN OFFICE
306W
OPEN OFFICE
329W
OFFICE
307W
DEMO LEGEND - FLOORING
EXISTING FLOORING TO
BE REMOVED
EXISTING FLOORING TO
REMAIN
EXISTING TO BE
REMOVED
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2
:2
:3
P
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2
:2
:3
P
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
LEVEL 3 COMPOSITE DEMOLITION PLAN - FLOORING
1550021
MATTCV
11.10.2023
AD103
N
SECTOR 2
SECTOR 1 SECTOR 3
SECTOR 4
HIGH BAY
1" = 20'-0"1
LEVEL 3 - COMPOSITE DEMO - FLOORING
0 10' 20' 40'
14 THE CONTRACTOR SHALL NOT BE RESPONSIBLE FOR HAZARDOUS MATERIAL MITIGATION.
SHOULD ANY BE DISCOVERED IT SHOULD BE BROUGHT TO THE ATTENTION OF THE FAA
AND THE ARCHITECT IMMEDIATELY AND BE HANDLED UNDER A SEPERATE CONTRACT.
13 EXISTING CEILING SYSTEMS (ACOUSTICAL CEILING PANELS AND GRID) ARE TO BE
DEMOLISHED IN EXISTING AREAS U.N.O. COORDINATE WITH M.E.P. FOR ALL CEILING ITEMS
TO BE REPLACED OR RE-USED WITHIN SCOPE OF WORK.
12 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE
INSTALLATION OF NEW CONSTRUCTION AND AS NECESSARY TO FULFILL THE PURPOSE
AND INTENT OF THE FINISH WORK, WHETHER OR NOT IT IS SPECIFICALLY SHOWN OR
NOTED IN THESE DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS
SLATED FOR DEMOLITION. THIS INCLUDES ANY ADDITIONAL CONCRETE SLAB CUTTING AND
TRENCHING FOR NEW PLUMBING.
11 PROTECT FROM DEMOLITION AND RECONSTRUCTION DEBRIS, ALL "EXISTING TO REMAIN"
FIXTURES, FINISHES, EQUIPMENT, ETC. REQUIRED TO REMAIN IN PLACE DURING
CONSTRUCTION.
10 ALL DEMOLITION MATERIAL IS TO BE LEGALLY DISPOSED OF IN ACCORDANCE WITH STATE, LOCAL AND FEDERAL LAW.
9 COORDINATE CEILING REMOVAL WITH ALL TRADES AS REQUIRED.
8 COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE ALL WORK WHICH
WILL AFFECT THE TENANTS ON ADJACENT FLOORS OR SPACES.
7 ANY DISCREPANCY FOUND ON DRAWINGS AND FIELD CONDITION SHALL BE BROUGHT TO
THE ATTENTION OF THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO
PROCEEDING WITH THE WORK IN QUESTION.
6 PROMPTLY REPAIR DAMAGES CAUSED TO ADJACENT AREAS BY DEMOLITION OPERATION
AT NO COST.
5 EXISTING ELECTRIC AND TELECOMMUNICATIONS OUTLETS INTERFERING WITH NEW WORK
SHALL BE REMOVED OR RELOCATED.
4 THE CONTRACTOR SHALL KEEP DUST TO A MINIMUM BEFORE AND DURING REMOVAL FROM
THE PREMISES. WHEN CUTTING INTO CONCRETE OR MASONRY TYPE MATERIAL,
CONTRACTOR MUST COMPLY WITH OSHA SILICA STD. 1926.1153, RESPIRABLE CRYSTALLINE
SILICA, TABLE 1.
3 THE CONTRACTOR SHALL REMOVE ALL WORK AS INDICATED ON THE CONSTRUCTION
DRAWING.
2 CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE
FOR ALL ITEMS SALVAGED BUT NOT REUSED.
1 DEMOLITION AND REMOVAL WORK SHALL BE DONE WITH DUE CARE, INCLUDING BRACING,
ETC. PERFORM PATCHING AND RESTORATION AS REQUIRED TO REMEDY AND RESTORE
SUCH DAMAGED PARTS EQUAL TO ADJACENT AREA.
DEMOLITION GENERAL NOTES
WEST - AMOUNT OF FLOORING TO BE REMOVED:
APPROX. 7,239 SQ. FT - V.I.F.
EAST - AMOUNT OF FLOORING TO BE REMOVED:
APPROX. 8,124 SQ. FT - V.I.F.
TOTAL LEVEL 3 ALL TYPES FLOORING REMOVAL:
APPROX. 15,363 SQ. FT - V.I.F.
LEVEL 3 CARPET REMOVAL:
APPROX. 11,289 SQ. FT - V.I.F.
NOTE: IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY ALL QUANTITIES
DEMOLISHED IN FIELD. NUMBERS LISTED ABOVE
ARE THE ARCHITECT'S BEST ESTIMATE BASED ON
OWNER PROVIDED RECORD DRAWINGS.
No. Date Description Issued by
Issued to
J
J
G
G
F
F
E
E
D
D
C
C
B
B
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
A-401
A-404
A-406
MEN
214W
WOMEN
215W
WOMEN
215E
MEN
218E
UNISEX
224E
MECHANICAL
227E
MEN
223E
WOMEN
225E
ELEV.
200QE
TELE.
220E
ELEV.
200JE
MECHANICAL
217E
ELEC.
216E
STAIR
207E
STAIR
201E
ELEV.
200DW
STAIR
200CW
WOMEN
202W
MEN
203AW
MECHANICAL
231W
ELEC.
226W
STAIR
200HW
ELEV.
200GW
JANITOR
217W
ELEC.
218W
OFFICE
228E
DEMO LEGEND - CEILINGS
EXISTING CEILINGS TO
BE REMOVED
EXISTING CEILINGS TO
REMAIN
EXISTING TO BE
REMOVED
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2
:2
:3
P
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2
:2
:3
P
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
LEVEL 2 COMPOSITE DEMOLITION PLAN - CEILINGS
1550021
MATTCV
11.10.2023
AD105
1" = 20'-0"1
LEVEL 2 - COMPOSITE DEMO - CEILINGS
N
SECTOR 2
SECTOR 1 SECTOR 3
SECTOR 4
HIGH BAY
14 THE CONTRACTOR SHALL NOT BE RESPONSIBLE FOR HAZARDOUS MATERIAL MITIGATION.
SHOULD ANY BE DISCOVERED IT SHOULD BE BROUGHT TO THE ATTENTION OF THE FAA
AND THE ARCHITECT IMMEDIATELY AND BE HANDLED UNDER A SEPERATE CONTRACT.
13 EXISTING CEILING SYSTEMS (ACOUSTICAL CEILING PANELS AND GRID) ARE TO BE
DEMOLISHED IN EXISTING AREAS U.N.O. COORDINATE WITH M.E.P. FOR ALL CEILING ITEMS
TO BE REPLACED OR RE-USED WITHIN SCOPE OF WORK.
12 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE
INSTALLATION OF NEW CONSTRUCTION AND AS NECESSARY TO FULFILL THE PURPOSE
AND INTENT OF THE FINISH WORK, WHETHER OR NOT IT IS SPECIFICALLY SHOWN OR
NOTED IN THESE DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS
SLATED FOR DEMOLITION. THIS INCLUDES ANY ADDITIONAL CONCRETE SLAB CUTTING AND
TRENCHING FOR NEW PLUMBING.
11 PROTECT FROM DEMOLITION AND RECONSTRUCTION DEBRIS, ALL "EXISTING TO REMAIN"
FIXTURES, FINISHES, EQUIPMENT, ETC. REQUIRED TO REMAIN IN PLACE DURING
CONSTRUCTION.
10 ALL DEMOLITION MATERIAL IS TO BE LEGALLY DISPOSED OF IN ACCORDANCE WITH STATE, LOCAL AND FEDERAL LAW.
9 COORDINATE CEILING REMOVAL WITH ALL TRADES AS REQUIRED.
8 COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE ALL WORK WHICH
WILL AFFECT THE TENANTS ON ADJACENT FLOORS OR SPACES.
7 ANY DISCREPANCY FOUND ON DRAWINGS AND FIELD CONDITION SHALL BE BROUGHT TO
THE ATTENTION OF THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO
PROCEEDING WITH THE WORK IN QUESTION.
6 PROMPTLY REPAIR DAMAGES CAUSED TO ADJACENT AREAS BY DEMOLITION OPERATION
AT NO COST.
5 EXISTING ELECTRIC AND TELECOMMUNICATIONS OUTLETS INTERFERING WITH NEW WORK
SHALL BE REMOVED OR RELOCATED.
4 THE CONTRACTOR SHALL KEEP DUST TO A MINIMUM BEFORE AND DURING REMOVAL FROM
THE PREMISES. WHEN CUTTING INTO CONCRETE OR MASONRY TYPE MATERIAL,
CONTRACTOR MUST COMPLY WITH OSHA SILICA STD. 1926.1153, RESPIRABLE CRYSTALLINE
SILICA, TABLE 1.
3 THE CONTRACTOR SHALL REMOVE ALL WORK AS INDICATED ON THE CONSTRUCTION
DRAWING.
2 CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE
FOR ALL ITEMS SALVAGED BUT NOT REUSED.
1 DEMOLITION AND REMOVAL WORK SHALL BE DONE WITH DUE CARE, INCLUDING BRACING,
ETC. PERFORM PATCHING AND RESTORATION AS REQUIRED TO REMEDY AND RESTORE
SUCH DAMAGED PARTS EQUAL TO ADJACENT AREA.
DEMOLITION GENERAL NOTES
No. Date Description Issued by
Issued to
J
J
G
G
F
F
E
E
D
D
C
C
B
B
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
ALL PENETRATIONS IN HIGH BAY
DEMISING WALLS, INCLUDING HANGAR
DOOR POCKETS, TO BE PROTECTED BY
AN APPROVED PENETRATION FIRESTOP
SYSTEM INSTALLED AS TESTED IN
ACCORDANCE WITH ASTM E814 OR UL
1479 AND SHALL HAVE AN 'F' RATING OF
NOT LESS THAN THE REQUIRED FIRE
RESISTANCE RATING OF THE WALL.
ALL PENETRATIONS IN HIGH BAY
DEMISING WALLS, INCLUDING HANGAR
DOOR POCKETS, TO BE PROTECTED BY
AN APPROVED PENETRATION FIRESTOP
SYSTEM INSTALLED AS TESTED IN
ACCORDANCE WITH ASTM E814 OR UL
1479 AND SHALL HAVE AN 'F' RATING OF
NOT LESS THAN THE REQUIRED FIRE
RESISTANCE RATING OF THE WALL.
MEN
143E
UNISEX
104E
UNISEX
107W
WOMEN
106W
MEN
115W
STAIR
100JW
A-111
A-111
A-112
A-112
HIGH BAY
O .T
.O . O
F B
U
IL
D
IN
G , V
.I.
F
7'
O.T.O. OF BUILDING, V.I.F.
278' - 8"
STAIR
100HW
ELEV.
100GW
STAIR
109BW
ELEV.
100DW
P A
R K
IN
G
S
ID
E
T A
R M
A C
S
ID
E
STAIR
100KE
STAIR
100PE
ELEV.
100QE
ELEV.
100JE
REFER TO INTERIOR DESIGN SHEETS FOR
STAIRWELL FLOORING INFORMATION, AT
ALL INTERIOR STAIRWELL LOCATIONS.
FLOORS TO BE PREPARED TO REDUCE
TRIP HAZARDS AT STAIR TREADS AND
FLOORING MATERIAL TRANSITIONS.
REPAIR OF ACCESS PANELS LOCATED IN
HANGAR DOOR POCKETS ARE NOT IN
THE SCOPE OF THIS PROJECT, TYPICAL
FOR ALL FOUR CORNERS OF HANGAR
BAY.
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/2
/2
:5 :5
P
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/2
/2
:5 :5
P
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
LEVEL 1 - COMPOSITE FLOOR PLAN
1550021
MATTCV
11.10.2023
A-110
N
SECTOR 2
SECTOR 1 SECTOR 3
SECTOR 4
HIGH BAY
1" = 20'-0"1
LEVEL 1 - COMPOSITE FLOOR PLAN
8 HANGAR BAY DEMISING WALLS TO RECEIVE NEW PAINT FINISH FULL HEIGHT TO BOTTOM OF
ROOF DECK. REMOVE BIRD NETTING FOR THE PURPOSE OF PAINTING THE WALL.
7 DIMENSIONS IN PLANS ARE TYPICALLY SHOWN TO:
A. COLUMN CENTERLINES.
B. FACE OF UNIT MASONRY OR CONCRETE.
C. FACE OF FRAMING WALLS.
D. FACE OF INTERIOR PARTITIONS (FACE OF CMU, IMP, MTL PANEL)
NOTE: WALL WITH APPLIED FINISHES ARE DIMENSIONED TO FACE OF FINISH U.O.N.
6 COORDINATE PLACEMENT OF FIRE ALARM HORN STROBES WITH FIRE PROTECTION...
5 EQUIPMENT SHOWN IN DRAWINGS IS NOT IN CONTRACT AND FURNISHED BY THE OWNER
U.O.N. REFER TO OWNER FURNISHED EQUIPMENT BOOK FOR SOME EQUIPMENT THAT
REQUIRES UTILITY CONNECTIONS IN CONTRACT
4 PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS
3 VERIFY EQUIPMENT REQUIREMENTS FOR ROUGH-IN AND UTILITY CONNECTIONS PRIOR TO
CONSTRUCTION TO ASSURE THAT PROPER BLOCKING, OPENINGS, AND UTILITY
CONNECTIONS ARE PROVIDED
2 THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS INDICATED ON
DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED FIELD DIMENSIONS. WHERE NO
DIMENSIONS OR METHOD OF DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT
PRIOR TO PROCEEDING.
1 CONTRACTOR SHALL REFER TO THE OKLAHOMA DEPARTMENT OF LABOR (ODOL)
REGULATIONS AND ALL APPLICABLE FAA ORDERS, NOTICES, PROTOCOLS AND OTHER
REQUIREMENTS.
GENERAL NOTES
0 10' 20' 40'
No. Date Description Issued by
Issued to
0 01.24.25 100% DESIGN SUBMITTAL TV FAA
2 06.26.25 AMENDMENT 2 TV FAA
E D C B
FILE STORAGE
230E
BREAK ROOM
229E
CONFERENCE ROOM
233EE
OPEN OFFICE
233E
OFFICE
233DE
OFFICE
233CE
OFFICE
233BE
OFFICE
233AE
OFFICE
228E
CORRIDOR
231E
MECHANICAL
227E
WOMEN
225E
ELEV.
200QE
UNISEX
224E
MEN
223E
CORRIDOR
226E
STAIR
201E
OPEN OFFICE
222E
OPEN OFFICE
203E
OFFICE
205AE
NO CEILING WORK IN HATCHED AREA
STAIRWELL SHALL
RECEIVE NEW 2X2
ACOUSTICAL GRID
CEILING - MATCH EXIST.
HEIGHT & SLOPES
EXP.
ACP-2
8' - 0" AFF
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1 EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
HIGH BAY
/2 A-222
NO CEILING WORK IN HATCHED AREA
E D C B
OFFICE
222AE
TELE.
220E
OFFICE
205E
OFFICE
205BE
OFFICE
205CE
OFFICE
206E
OFFICE
206AE
CORRIDOR
212E
STAIR
207E
MEN
218E
ELEV.
200JE
MECHANICAL
217E
ELEC.
216E
OFFICE
209AE
OFFICE
209BE
COPIER
214E
CONFERENCE ROOM
213AE
OPEN OFFICE
210E
OFFICE
213BE
OPEN OFFICE
213E
OFFICE
213CE
A-301
OPEN OFFICE
222E
WOMEN
215E
VEST.
215AE
JANITOR
215BE
OFFICE
209E
STAIRWELL SHALL RECEIVE
NEW 2X2 ACOUSTICAL
GRID CEILING - MATCH
EXIST. HEIGHT & SLOPES
ACP-2
8' - 0" AFF
ACP-2
8' - 0" AFF
ACP-1
8' - 0" AFF
3A-GWB
8' - 0" AFF
3A-GWB
9' - 0" AFF
EXP.
EXP.
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
EXIST. HT.
ACP-1
HIGH BAY
/1 A-222
2X2 ACOUSTICAL CEILING TILE
GYPSUM WALLBOARD CEILING
EXPOSED TO STRUCTURE ABOVEXXEXP
REFLECTED CEILING PLAN LEGEND
EXIT SIGN
RECESSED CAN DOWNLIGHT
PENDANT LIGHT
2X4 RECESSED LIGHT
2X2 RECESSED LIGHT
2X2 ACOUSTICAL CEILING TILE
MOISTURE RESISTANT
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2
:2
:2
P
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2
:2
:2
P
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
LEVEL 2 - SECTORS 3 & 4 RCP
1550021
MATTCV
11.10.2023
A-222
N
SECTOR 2
SECTOR 1 SECTOR 3
SECTOR 4
HIGH BAY
1/8" = 1'-0"1
LEVEL 2 - SECTOR 3 RCP
0 4' 8' 16' 1/8" = 1'-0"2
LEVEL 2 - SECTOR 4 RCP
0 4' 8' 16'
5 HVAC DIFFUSERS ARE NOT SHOWN ON ARCHITECTURAL CEILING PLANS. HVAC DIFFUSERS
ARE EXISTING AND SHALL BE RE-USED. CONTRACTOR SHALL PROTECT DIFFUSERS
DURING CEILING DEMOLITION AND RE-USE AND RELOCATE WITHIN NEW CEILING GRID.
REFERENCE HVAC DRAWINGS.
4 DESIGN INTENT - INSTALL RECESSED CAN LIGHTS AT CENTER OF LAY-IN CEILING TILE.
3 PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS
2 IN ALL CONTINUOUS, UNINTERRUPTED GYPSUM BOARD CEILINGS, PROVIDE CONTROL
JOINTS AT INTERVALS SPECIFIED (BUT NOT GREATER THAN 30 FEET). VERIFY LOCATIONS
WITH ARCHITECT PRIOR TO PROCEEDING.
1 ALL NEW CEILINGS ARE TO BE INSTALLED AT THE EXISTING CEILING HEIGHT UNO.
CONTRACTOR SHALL FIELD VERIFY EXISTING HEIGHT.
GENERAL CEILING NOTES
No. Date Description Issued by
Issued to
D
UNISEX
104E
1 3 11
D
UNISEX
104E
16"-18"
D
B2
C
B1
E
G
B3
A-424 14
AK
15" MIN. 5'-0" MIN.
H
V.I.F.
7' - 2"
D
UNISEX
224E
1 3 11
D
UNISEX
224E
TYP.
1' - 6"
E
G
B2C
A
B3
K
B1 A-424
D
224E
H
15" MIN.
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2
:3 1:
P
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2
:3 1:
P
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
ENLARGED PLANS - 104E, 224E
1550021
MATTCV
11.10.2023
A-401
10 DESIGN INTENT: LIGHT FIXTURES ABOVE VANITY TO BE
CENTERED ON VANITY.
9 THE CONTRACTOR SHALL PROVIDE A RUBBERMAID
RG266400 GRAY SQUARE TOP TRASH RECEPTACLE IN
EVERY RENOVATED RESTROOM.
8 PROVIDE BLOCKING IN WALLS BEHIND NEW GRAB BARS.
7 ALL RESTROOMS SHALL RECEIVE UPDATED FINISHES
U.O.N. ON THE DRAWINGS.
6 ALL NEWLY INSTALLED DRINKING FOUNTAINS SHALL BE
FLUSHED FOR 15 MINUTES. CONTACT AMP-100, DUANE
ROE AT (405) 365-5829 FOR TESTING AND CLEARANCE.
5 ALL NEW TOILET ROOM WALLS AND CEILINGS SHALL
HAVE MOISTURE RESISTANT GYPSUM BOARD.
4 ALL DIMENSIONS WITH THE NOTE "CLEAR" ARE FROM
FACE OF WALL FINISH TO WALL FINISH.
3 PROVIDE ONCE COAT HOOK MOUNTED ON INSIDE FACE
OF EACH STALL DOOR OR ON BACK OF ENTRY DOOR IN
SINGLE USER RESTROOMS.
2 ALL NEW TOILET ROOM WALLS SHALL HAVE AN STC-45
RATING.
1 HANDICAP ACCESSORY MOUNTING DIMENSIONS ARE
CRITICAL AND ARE TO BE INSTALLED IN ACCORDANCE
WITH ANSI 117.1 - 2009
TOILET GENERAL NOTES
TOILET ACCESSORIES - SEE SHEET G-002 FOR MOUNTING HEIGHTS
MARK DESCRIPTION COMMENTS
A TOILET TISSUE DISPENSER (DOUBLE ROLL
JUMBO)
KIMBERLY-CLARK 09551-01 JUMBO
TISSUE
B1 42" ADA GRAB BAR
B2 36” ADA GRAB BAR
B3 18" VERTICAL GRAB BAR
C FEMININE NAPKIN DISPOSAL ITEM # 47131703
D SOAP DISPENSER GOJO 5271-06
E TOUCHLESS PAPER TOWEL DISPENSER KIMBERLY-CLARK 09990-03
F COAT HOOK
G HAND SANITIZER PURELL NXT SPACE SAVER 2120-06
H 18" X 36" MIRROR STAINLESS FRAME
J URINAL SCREEN MOUNTED 18" A.F.F.
K TOILET SEAT COVER DISPENSER KIMBERLY-CLARK 09506-01
3/8" = 1'-0"1
LEVEL 1 - UNISEX 104E DEMO
GENERAL DEMOLITION NOTES:
1. CONTRACTOR SHALL DISPOSE OF ALL MATERIALS IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL LAWS.
2. PROTECT ADJACENT SURFACES AND AREAS TO REMAIN.
DAMAGE CAUSED BY DEMOLITION AND/OR NEW
CONSTRUCTION SHALL BE REPAIRED AS NECESSARY TO
LIKE NEW OR BETTER CONDITION.
KEYED NOTES (THIS SHEET)#
0 1' 2' 4' 6' 3/8" = 1'-0"2
LEVEL 1 - UNISEX 104E
0 1' 2' 4' 6'
3/8" = 1'-0"3
LEVEL 2 - UNISEX 224E DEMO
3/8" = 1'-0"4
LEVEL 2 - UNISEX 224E
0 1' 2' 4' 6' 0 1' 2' 4' 6'
1. DEMO AND REMOVE EXISTING FLOOR FINISHES.
FLOORS TO RECEIVE NEW FINISHES AS SCHEDULED.
2. DEMO AND REMOVE EXISTING DOOR AND FRAME.
3. DEMO AND REMOVE EXISTING TOILETS, ALL TOILET
ROOM FIXTURES, GRAB BARS, TP DISPENSERS,
MIRRORS, ETC.
4. DEMO AND REMOVE EXISTING URINALS AND UNRINAL
SCREENS.
5. DEMO AND REMOVE EXISTING METAL TOILET
PARTITIONS.
6. DEMO AND REMOVE EXISTING SINK(S) AND ALL
COUNTERS, CABINETS AND COMPONENTS AS
REQUIRED.
7. DEMO AND REMOVE EXISTING EWC.
8. DEMO AND REMOVE INDICATED PORTION OF EXISTING
BLOCK AND/OR CLAY TILE PARTITION - FULL HEIGHT.
9. DEMO AND REMOVE EXISTING WALL FURRING.
10. DEMO AND REMOVE EXISTING JANITOR SINK.
11. DEMO AND REMOVE EXISTING WALL FINISHES (TILE,
PAINT) AS REQUIRED, PREPARE WALLS FOR NEW
FINISHES.
12. DEMO AND REMOVE INDICATED PORTION OF FRAMED
PARTITION.
13. DEMO AND REMOVE EXISTING RF SHIELDED PANELS
AND ALL APPLICABLE COMPONENTS. PREP DAMAGED
SURFACES FOR INSTALLATION OF NEW FINISHES.
14. REMOVE PORTIONS OF EXISTING WALL FOR REMOVAL
AND INSTALLATION OF PLUMBING AND PLUMBING
COMPONENTS, AS REQUIRED. REPAIR AND PREP WALL
FOR INSTALLATION OF NEW FINISHES.
15. DEMO AND REMOVE EXISTING CEILING AND ALL
EXISTING FIXTURES ON OR WITHIN CEILING. PREP
WALLS FOR INSTALLATION OF NEW CEILING.
16. PATCH AND REPAIR EXIST. CONCRETE FLOOR AT
LOCATIONS WHERE EXIST. BLOCK AND/OR CLAY TILE
PARTITION HAS BEEN REMOVED, TO MATCH ADJACENT
FLOOR LEVEL. REF. INTERIOR DRAWINGS FOR FINISH.
17. INFILL FLOOR SLAB WHERE REMOVED FOR
INSTALLATION OF PLUMBING. MATCH ADJACENT FLOOR
LEVEL. REF. INTERIORS FOR FINISH.
18. 12" X 12" ACCESS PANEL MOUNTED 2'-0" A.F.F.
No. Date Description Issued by
Issued to
0 01.24.25 100% DESIGN SUBMITTAL TV FAA
2 06.26.25 AMENDMENT 2 TV FAA
E D C
1 3 11
MEN
143E
ELEC.
144E
E D C
7' - 2 1/2" 5' - 10" +/- 4' - 4"
2'
5'
1'
3/ 4"
3'
4"
CL.
143BE
ELEC.
144E
MEN
143E
VESTIBULE
143AE
143BE
143AE143E
A-420
G
D
H
E
H
D
B2
B1
A
K
B3
EWC
E
10" 11' - 3"
6'
0"
S
- D
T6 A6
S
- D
T6
A6
S
- D
T.16 A6
S
- +6
-3
S
- +6
-3
S
- +6
-3
S
- D
.1T6
A6
S
- D
.1T6
A6
S
- D
.1T6
A6
S
- +6
.1T3
S
- +6
.1T3
3'-0" CLEAR5'-0" CLEAR
A A
K K
A-501
A-501
1'
CORRIDOR
147E
S
- D
.13
A3
3'-0" CLEAR
11' - 4 1/2" 7' - 4" +/-
S
D
T.13
A3
5'
TYP.
1' - 6"
6'
CL
C
LE
A R
8'
0"
2'
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2
:3 1:
P
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2
:3 1:
P
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
ENLARGED PLANS - 143E
1550021
MATTCV
11.10.2023
A-402
10 DESIGN INTENT: LIGHT FIXTURES ABOVE VANITY TO BE
CENTERED ON VANITY.
9 THE CONTRACTOR SHALL PROVIDE A RUBBERMAID
RG266400 GRAY SQUARE TOP TRASH RECEPTACLE IN
EVERY RENOVATED RESTROOM.
8 PROVIDE BLOCKING IN WALLS BEHIND NEW GRAB BARS.
7 ALL RESTROOMS SHALL RECEIVE UPDATED FINISHES
U.O.N. ON THE DRAWINGS.
6 ALL NEWLY INSTALLED DRINKING FOUNTAINS SHALL BE
FLUSHED FOR 15 MINUTES. CONTACT AMP-100, DUANE
ROE AT (405) 365-5829 FOR TESTING AND CLEARANCE.
5 ALL NEW TOILET ROOM WALLS AND CEILINGS SHALL
HAVE MOISTURE RESISTANT GYPSUM BOARD.
4 ALL DIMENSIONS WITH THE NOTE "CLEAR" ARE FROM
FACE OF WALL FINISH TO WALL FINISH.
3 PROVIDE ONCE COAT HOOK MOUNTED ON INSIDE FACE
OF EACH STALL DOOR OR ON BACK OF ENTRY DOOR IN
SINGLE USER RESTROOMS.
2 ALL NEW TOILET ROOM WALLS SHALL HAVE AN STC-45
RATING.
1 HANDICAP ACCESSORY MOUNTING DIMENSIONS ARE
CRITICAL AND ARE TO BE INSTALLED IN ACCORDANCE
WITH ANSI 117.1 - 2009
TOILET GENERAL NOTES
TOILET ACCESSORIES - SEE SHEET G-002 FOR MOUNTING HEIGHTS
MARK DESCRIPTION COMMENTS
A TOILET TISSUE DISPENSER (DOUBLE ROLL
JUMBO)
KIMBERLY-CLARK 09551-01 JUMBO
TISSUE
B1 42" ADA GRAB BAR
B2 36” ADA GRAB BAR
B3 18" VERTICAL GRAB BAR
C FEMININE NAPKIN DISPOSAL ITEM # 47131703
D SOAP DISPENSER GOJO 5271-06
E TOUCHLESS PAPER TOWEL DISPENSER KIMBERLY-CLARK 09990-03
F COAT HOOK
G HAND SANITIZER PURELL NXT SPACE SAVER 2120-06
H 18" X 36" MIRROR STAINLESS FRAME
J URINAL SCREEN MOUNTED 18" A.F.F.
K TOILET SEAT COVER DISPENSER KIMBERLY-CLARK 09506-01
GENERAL DEMOLITION NOTES:
1. CONTRACTOR SHALL DISPOSE OF ALL MATERIALS IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL LAWS.
2. PROTECT ADJACENT SURFACES AND AREAS TO REMAIN.
DAMAGE CAUSED BY DEMOLITION AND/OR NEW
CONSTRUCTION SHALL BE REPAIRED AS NECESSARY TO
LIKE NEW OR BETTER CONDITION.
KEYED NOTES (THIS SHEET)#
3/8" = 1'-0"1
LEVEL 1 - MEN 143E DEMO
3/8" = 1'-0"2
LEVEL 1 - MEN 143E
0 1' 2' 4' 6' 0 1' 2' 4' 6'
1. DEMO AND REMOVE EXISTING FLOOR FINISHES.
FLOORS TO RECEIVE NEW FINISHES AS SCHEDULED.
2. DEMO AND REMOVE EXISTING DOOR AND FRAME.
3. DEMO AND REMOVE EXISTING TOILETS, ALL TOILET
ROOM FIXTURES, GRAB BARS, TP DISPENSERS,
MIRRORS, ETC.
4. DEMO AND REMOVE EXISTING URINALS AND UNRINAL
SCREENS.
5. DEMO AND REMOVE EXISTING METAL TOILET
PARTITIONS.
6. DEMO AND REMOVE EXISTING SINK(S) AND ALL
COUNTERS, CABINETS AND COMPONENTS AS
REQUIRED.
7. DEMO AND REMOVE EXISTING EWC.
8. DEMO AND REMOVE INDICATED PORTION OF EXISTING
BLOCK AND/OR CLAY TILE PARTITION - FULL HEIGHT.
9. DEMO AND REMOVE EXISTING WALL FURRING.
10. DEMO AND REMOVE EXISTING JANITOR SINK.
11. DEMO AND REMOVE EXISTING WALL FINISHES (TILE,
PAINT) AS REQUIRED, PREPARE WALLS FOR NEW
FINISHES.
12. DEMO AND REMOVE INDICATED PORTION OF FRAMED
PARTITION.
13. DEMO AND REMOVE EXISTING RF SHIELDED PANELS
AND ALL APPLICABLE COMPONENTS. PREP DAMAGED
SURFACES FOR INSTALLATION OF NEW FINISHES.
14. REMOVE PORTIONS OF EXISTING WALL FOR REMOVAL
AND INSTALLATION OF PLUMBING AND PLUMBING
COMPONENTS, AS REQUIRED. REPAIR AND PREP WALL
FOR INSTALLATION OF NEW FINISHES.
15. DEMO AND REMOVE EXISTING CEILING AND ALL
EXISTING FIXTURES ON OR WITHIN CEILING. PREP
WALLS FOR INSTALLATION OF NEW CEILING.
16. PATCH AND REPAIR EXIST. CONCRETE FLOOR AT
LOCATIONS WHERE EXIST. BLOCK AND/OR CLAY TILE
PARTITION HAS BEEN REMOVED, TO MATCH ADJACENT
FLOOR LEVEL. REF. INTERIOR DRAWINGS FOR FINISH.
17. SAW CUT FLOOR SLAB AT INDICATED AREA TO ALLOW
FOR INSTALLATION OF NEW PLUMBING.
18. INFILL FLOOR SLAB WHERE REMOVED FOR
INSTALLATION OF PLUMBING. MATCH ADJACENT FLOOR
LEVEL. REF. INTERIORS FOR FINISH.
19. 12" X 12" ACCESS PANEL MOUNTED 2'-0" A.F.F.
No. Date Description Issued by
Issued to
0 01.24.25 100% DESIGN SUBMITTAL TV FAA
2 06.26.25 AMENDMENT 2 TV FAA
G
UNISEX
107W
WOMEN
106W
1 3
11 1 3
2 2
15 15
G
UNISEX
107W
WOMEN
106W
A-423
1'
1' - 6"
A-42412
G
D
B2
E
K
B1 B3 A C
G
E
DB2C
B1
A
B3
K
B1
106W107W
6'
1"
7' - 7 1/2" 1' - 3" 7' - 11 1/2"
S
- D
T.16
A6
S
- D
T.16 A6
S
- D
.1T3
A3
S
- D
.1T6
A6
EWC
S
- D
.1T3
A3
15" MIN.
S
- D
.1T6 A6
16" - 18"
5'-0" MIN.
H
H
5' -0
M
IN
5' - 0" MIN.
G
4 6
1 3 11
MEN
115W
G
MEN
115W
A-4204
H DHE
B2
B1
K
B3
A
G
K
5'-0" CLEAR
16" - 18"
A
3'-0" CLEAR
D
J
S
- D
.1T6
A6
S
- D
.1T6 A6
5'
/4
6' - 0"
1'
/2
1'
8'
/2
6' - 2" 11' - 6" +/-
1' - 7 1/2"
3' - 2"
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2
:3 1:
P
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2
:3 1:
P
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
ENLARGED PLANS - 107W, 106W, 115W
1550021
MATTCV
11.10.2023
A-403
10 DESIGN INTENT: LIGHT FIXTURES ABOVE VANITY TO BE
CENTERED ON VANITY.
9 THE CONTRACTOR SHALL PROVIDE A RUBBERMAID
RG266400 GRAY SQUARE TOP TRASH RECEPTACLE IN
EVERY RENOVATED RESTROOM.
8 PROVIDE BLOCKING IN WALLS BEHIND NEW GRAB BARS.
7 ALL RESTROOMS SHALL RECEIVE UPDATED FINISHES
U.O.N. ON THE DRAWINGS.
6 ALL NEWLY INSTALLED DRINKING FOUNTAINS SHALL BE
FLUSHED FOR 15 MINUTES. CONTACT AMP-100, DUANE
ROE AT (405) 365-5829 FOR TESTING AND CLEARANCE.
5 ALL NEW TOILET ROOM WALLS AND CEILINGS SHALL
HAVE MOISTURE RESISTANT GYPSUM BOARD.
4 ALL DIMENSIONS WITH THE NOTE "CLEAR" ARE FROM
FACE OF WALL FINISH TO WALL FINISH.
3 PROVIDE ONCE COAT HOOK MOUNTED ON INSIDE FACE
OF EACH STALL DOOR OR ON BACK OF ENTRY DOOR IN
SINGLE USER RESTROOMS.
2 ALL NEW TOILET ROOM WALLS SHALL HAVE AN STC-45
RATING.
1 HANDICAP ACCESSORY MOUNTING DIMENSIONS ARE
CRITICAL AND ARE TO BE INSTALLED IN ACCORDANCE
WITH ANSI 117.1 - 2009
TOILET GENERAL NOTES
TOILET ACCESSORIES - SEE SHEET G-002 FOR MOUNTING HEIGHTS
MARK DESCRIPTION COMMENTS
A TOILET TISSUE DISPENSER (DOUBLE ROLL
JUMBO)
KIMBERLY-CLARK 09551-01 JUMBO
TISSUE
B1 42" ADA GRAB BAR
B2 36” ADA GRAB BAR
B3 18" VERTICAL GRAB BAR
C FEMININE NAPKIN DISPOSAL ITEM # 47131703
D SOAP DISPENSER GOJO 5271-06
E TOUCHLESS PAPER TOWEL DISPENSER KIMBERLY-CLARK 09990-03
F COAT HOOK
G HAND SANITIZER PURELL NXT SPACE SAVER 2120-06
H 18" X 36" MIRROR STAINLESS FRAME
J URINAL SCREEN MOUNTED 18" A.F.F.
K TOILET SEAT COVER DISPENSER KIMBERLY-CLARK 09506-01
GENERAL DEMOLITION NOTES:
1. CONTRACTOR SHALL DISPOSE OF ALL MATERIALS IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL LAWS.
2. PROTECT ADJACENT SURFACES AND AREAS TO REMAIN.
DAMAGE CAUSED BY DEMOLITION AND/OR NEW
CONSTRUCTION SHALL BE REPAIRED AS NECESSARY TO
LIKE NEW OR BETTER CONDITION.
KEYED NOTES (THIS SHEET)#
3/8" = 1'-0"1
LEVEL 1 - UNISEX 107W, WOMEN 106W DEMO
3/8" = 1'-0"2
LEVEL 1 - UNISEX 107W, WOMEN 106W
3/8" = 1'-0"3
LEVEL 1 - MEN 115W DEMO
3/8" = 1'-0"4
LEVEL 1 - MEN 115W
0 1' 2' 4' 6' 0 1' 2' 4' 6'
0 1' 2' 4' 6' 0 1' 2' 4' 6'
1. DEMO AND REMOVE EXISTING FLOOR FINISHES.
FLOORS TO RECEIVE NEW FINISHES AS SCHEDULED.
2. DEMO AND REMOVE EXISTING DOOR AND FRAME.
3. DEMO AND REMOVE EXISTING TOILETS, ALL TOILET
ROOM FIXTURES, GRAB BARS, TP DISPENSERS,
MIRRORS, ETC.
4. DEMO AND REMOVE EXISTING URINALS AND UNRINAL
SCREENS.
5. DEMO AND REMOVE EXISTING METAL TOILET
PARTITIONS.
6. DEMO AND REMOVE EXISTING SINK(S) AND ALL
COUNTERS, CABINETS AND COMPONENTS AS
REQUIRED.
7. DEMO AND REMOVE EXISTING EWC.
8. DEMO AND REMOVE INDICATED PORTION OF EXISTING
BLOCK AND/OR CLAY TILE PARTITION - FULL HEIGHT.
9. DEMO AND REMOVE EXISTING WALL FURRING.
10. DEMO AND REMOVE EXISTING JANITOR SINK.
11. DEMO AND REMOVE EXISTING WALL FINISHES (TILE,
PAINT) AS REQUIRED, PREPARE WALLS FOR NEW
FINISHES.
12. DEMO AND REMOVE INDICATED PORTION OF FRAMED
PARTITION.
13. DEMO AND REMOVE EXISTING RF SHIELDED PANELS
AND ALL APPLICABLE COMPONENTS. PREP DAMAGED
SURFACES FOR INSTALLATION OF NEW FINISHES.
14. REMOVE PORTIONS OF EXISTING WALL FOR REMOVAL
AND INSTALLATION OF PLUMBING AND PLUMBING
COMPONENTS, AS REQUIRED. REPAIR AND PREP WALL
FOR INSTALLATION OF NEW FINISHES.
15. DEMO AND REMOVE EXISTING CEILING AND ALL
EXISTING FIXTURES ON OR WITHIN CEILING. PREP
WALLS FOR INSTALLATION OF NEW CEILING.
16. PATCH AND REPAIR EXIST. CONCRETE FLOOR AT
LOCATIONS WHERE EXIST. BLOCK AND/OR CLAY TILE
PARTITION HAS BEEN REMOVED, TO MATCH ADJACENT
FLOOR LEVEL. REF. INTERIOR DRAWINGS FOR FINISH.
17. INFILL FLOOR SLAB WHERE REMOVED FOR
INSTALLATION OF PLUMBING. MATCH ADJACENT FLOOR
LEVEL. REF. INTERIORS FOR FINISH.
18. 12" X 12" ACCESS PANEL MOUNTED 2'-0" A.F.F.
No. Date Description Issued by
Issued to
0 01.24.25 100% DESIGN SUBMITTAL TV FAA
2 06.26.25 AMENDMENT 2 TV FAA
5 4
1 3 11
1 3 11
WOMEN
215E
MEN
218E
1 11 15
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/2
/2
:5 :0
P
M A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/2
/2
:5 :0
P
M A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
ENLARGED PLANS - 215E, 218E
1550021
MATTCV
11.10.2023
A-404
10 DESIGN INTENT: LIGHT FIXTURES ABOVE VANITY TO BE
CENTERED ON VANITY.
9 THE CONTRACTOR SHALL PROVIDE A RUBBERMAID
RG266400 GRAY SQUARE TOP TRASH RECEPTACLE IN
EVERY RENOVATED RESTROOM.
8 PROVIDE BLOCKING IN WALLS BEHIND NEW GRAB BARS.
7 ALL RESTROOMS SHALL RECEIVE UPDATED FINISHES
U.O.N. ON THE DRAWINGS.
6 ALL NEWLY INSTALLED DRINKING FOUNTAINS SHALL BE
FLUSHED FOR 15 MINUTES. CONTACT AMP-100, DUANE
ROE AT (405) 365-5829 FOR TESTING AND CLEARANCE.
5 ALL NEW TOILET ROOM WALLS AND CEILINGS SHALL
HAVE MOISTURE RESISTANT GYPSUM BOARD.
4 ALL DIMENSIONS WITH THE NOTE "CLEAR" ARE FROM
FACE OF WALL FINISH TO WALL FINISH.
3 PROVIDE ONCE COAT HOOK MOUNTED ON INSIDE FACE
OF EACH STALL DOOR OR ON BACK OF ENTRY DOOR IN
SINGLE USER RESTROOMS.
2 ALL NEW TOILET ROOM WALLS SHALL HAVE AN STC-45
RATING.
1 HANDICAP ACCESSORY MOUNTING DIMENSIONS ARE
CRITICAL AND ARE TO BE INSTALLED IN ACCORDANCE
WITH ANSI 117.1 - 2009
TOILET GENERAL NOTES
TOILET ACCESSORIES - SEE SHEET G-002 FOR MOUNTING HEIGHTS
MARK DESCRIPTION COMMENTS
A TOILET TISSUE DISPENSER (DOUBLE ROLL
JUMBO)
KIMBERLY-CLARK 09551-01 JUMBO
TISSUE
B1 42" ADA GRAB BAR
B2 36” ADA GRAB BAR
B3 18" VERTICAL GRAB BAR
C FEMININE NAPKIN DISPOSAL ITEM # 47131703
D SOAP DISPENSER GOJO 5271-06
E TOUCHLESS PAPER TOWEL DISPENSER KIMBERLY-CLARK 09990-03
F COAT HOOK
G HAND SANITIZER PURELL NXT SPACE SAVER 2120-06
H 18" X 36" MIRROR STAINLESS FRAME
J URINAL SCREEN MOUNTED 18" A.F.F.
K TOILET SEAT COVER DISPENSER KIMBERLY-CLARK 09506-01
GENERAL DEMOLITION NOTES:
1. CONTRACTOR SHALL DISPOSE OF ALL MATERIALS IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL LAWS.
2. PROTECT ADJACENT SURFACES AND AREAS TO REMAIN.
DAMAGE CAUSED BY DEMOLITION AND/OR NEW
CONSTRUCTION SHALL BE REPAIRED AS NECESSARY TO
LIKE NEW OR BETTER CONDITION.
KEYED NOTES (THIS SHEET)#
3/8" = 1'-0"1
LEVEL 2 - WOMEN 215E, MEN 218E DEMO
0 1' 2' 4' 6'
1. DEMO AND REMOVE EXISTING FLOOR FINISHES.
FLOORS TO RECEIVE NEW FINISHES AS SCHEDULED.
2. DEMO AND REMOVE EXISTING DOOR AND FRAME.
3. DEMO AND REMOVE EXISTING TOILETS, ALL TOILET
ROOM FIXTURES, GRAB BARS, TP DISPENSERS,
MIRRORS, ETC.
4. DEMO AND REMOVE EXISTING URINALS AND UNRINAL
SCREENS.
5. DEMO AND REMOVE EXISTING METAL TOILET
PARTITIONS.
6. DEMO AND REMOVE EXISTING SINK(S) AND ALL
COUNTERS, CABINETS AND COMPONENTS AS
REQUIRED.
7. DEMO AND REMOVE EXISTING EWC.
8. DEMO AND REMOVE INDICATED PORTION OF EXISTING
BLOCK AND/OR CLAY TILE PARTITION - FULL HEIGHT.
9. DEMO AND REMOVE EXISTING WALL FURRING.
10. DEMO AND REMOVE EXISTING JANITOR SINK.
11. DEMO AND REMOVE EXISTING WALL FINISHES (TILE,
PAINT) AS REQUIRED, PREPARE WALLS FOR NEW
FINISHES.
12. DEMO AND REMOVE INDICATED PORTION OF FRAMED
PARTITION.
13. DEMO AND REMOVE EXISTING RF SHIELDED PANELS
AND ALL APPLICABLE COMPONENTS. PREP DAMAGED
SURFACES FOR INSTALLATION OF NEW FINISHES.
14. REMOVE PORTIONS OF EXISTING WALL FOR REMOVAL
AND INSTALLATION OF PLUMBING AND PLUMBING
COMPONENTS, AS REQUIRED. REPAIR AND PREP WALL
FOR INSTALLATION OF NEW FINISHES.
15. DEMO AND REMOVE EXISTING CEILING AND ALL
EXISTING FIXTURES ON OR WITHIN CEILING. PREP
WALLS FOR INSTALLATION OF NEW CEILING.
16. PATCH AND REPAIR EXIST. CONCRETE FLOOR AT
LOCATIONS WHERE EXIST. BLOCK AND/OR CLAY TILE
PARTITION HAS BEEN REMOVED, TO MATCH ADJACENT
FLOOR LEVEL. REF. INTERIOR DRAWINGS FOR FINISH.
17. INFILL FLOOR SLAB WHERE REMOVED FOR
INSTALLATION OF PLUMBING. MATCH ADJACENT FLOOR
LEVEL. REF. INTERIORS FOR FINISH.
No. Date Description Issued by
Issued to
E
D C
6' - 10" +/- 10' - 4 1/2" 2'
/2
1'
JANITOR
215BE
ELEC.
216E
WOMEN
215E
MEN
218E
218E
215E 215AE
215BE
VEST.
215AE
A-4214
A-423
G
D
E
B1 B3
A
B2
K
B1
B3
A
B2
G D
E
D
H
H
EWC
10" 11' - 5"
LOUNGE AREA
2'
10"
S D
T.13 A3
S
- D
.1T6
A6
S
- D
.1T6
A6 S
- +6
.1T3
S
- +6
.1T3
S
- D
.1T3 A3
S
- D
.1T3
A3
S
- D
T6 A6
S D
T.13 A3
S
- +6
-3
S
- +6
-6
S
- +6
-3
S
- D
.13
A3
S
- D
.13
A3
S
- D
T6 A6
K K C C
AA
A-501
3' - 5 5/8"
11' - 5" 1' - 11" +/-
5'-0" CLEAR 3'-0" CLEAR 3'-0" CLEAR
9'
5'-0" CLEAR
5'
ELEV.
200JE
MECHANICAL
217E
CORRIDOR
218AE
CORRIDOR
212E
16" - 18"
16" - 18"
H
7'
/2
6'
A
LI
G N
ALIGN
2'
/2
M
IN
5'
A
LI
G N
Drawing No. AMP - 400 -lead or pm designed drawn approved by
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
ISSUED BY
OFFICE OF
facility management amp − 400 drawn d r a w in g N a m e d r a w in g N a m e
AMENDMENT 2
SEAL:
/3
/2
:3 1:
P M
A u t o d e s k D o c s /1 F A A H a n g a r
R e n o v a t io n s R /1 1_
A R C H H C F .r v t
/3
/2
:3 1:
P M
A u t o d e s k D o c s /1 F A A H a n g a r R e n o v a t io n s R /1 1_
A R C H H C F .r v t
B. BRADDICK
T. AUFRANC
HANGAR 9
ENLARGED PLANS - 215E, 218E
1550021
MATTCV
11.10.2023
A-405
10 DESIGN INTENT: LIGHT FIXTURES ABOVE VANITY TO BE
CENTERED ON VANITY.
9 THE CONTRACTOR SHALL PROVIDE A RUBBERMAID
RG266400 GRAY SQUARE TOP TRASH RECEPTACLE IN
EVERY RENOVATED RESTROOM.
8 PROVIDE…
This is the start of the file's text. The full file is on GovTribe.