This document provides details for a federal construction solicitation to build a new mental health building at the Providence VA Medical Center. The Department of Veterans Affairs intends to issue a request for proposal for a firm-fixed-price design-bid-build construction contract. The project scope involves preparing the site, demolishing existing structures, and constructing a new three-story, approximately 15,300 square foot freestanding mental health building including corresponding site and utility work. The solicitation will be set aside for Service-Disabled Veteran-Owned Small Businesses and issued on or around December 20, 2019. The period of performance is expected to be approximately 600 calendar days. The magnitude of construction is estimated between $10-20 million. All questions must be submitted in writing by the specified deadline.
36E77620R0001 0005 Attachment 3 - Addendum02.pdf
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum Number 02 VA Project: 650-332
VAMC Providence
Mental Health Building Phase 1
February 3rd, 2020
To: Prospective Bidders
From:
WBRC ARCHITECTS ENGINEERS
30 Danforth Street
Portland, ME 04101
(207) 828-4511 www.wbrcae.com
This Addendum forms a part of the Contract Documents and modifies the original
Bidding Documents dated April 10, 2019, as noted below. Acknowledge receipt of the
Addendum in the space provided on the Bid Form. Failure to do so may subject the
Bidder to disqualification.
This Addendum consists of the following:
- Drawing Changes
DRAWING CHANGES:
Revisions to 1hr rated partition identification and details.
1. Sheet AE601, Partition Types and Details, DELETE and REPLACE with attached sheet.
END OF ADDENDUM
http://www.wbrcae.com/
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8"
TYPE "X" GWB. ON
BOTH SIDES OF METAL
STUD @ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
MINERAL FIBER
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
SEALANT BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE VA PARTITION # STUD SIZE
METAL STUD WALL STUD SIZE SCHEDULE
M2 09P22M2 2 1/2"
M6 09P62M6 6"
M8 09P82M8 8"
M4 09P42M4 3 5/8"
AE601
C6 Sim CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
NOTE: MINIMUM SOUND TRANSMISSION CLASS RATING OF STC-49
M4B 09P42M4B 3 5/8"
RATING
1HR
UL DES U465
M6B 09P62M6B 6"
1HR
UL DES U465
AE601
C3
Sim AT 1HR WALLS
ATTACH RUNNERS TO FLOOR @
24" O.C. AND WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL
SEALANT
SCHEDULED FLOOR
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8" TYPE
"X" GWB. ON ONE SIDE OF
METAL STUD @ 16" O.C.
SEE SCHEDULE FOR STUD
SIZES.
MINERAL FIBER INSULATION
FRICTION FIT FOR SOUND
DEADENING. SAME THICKNESS
AS WALL STUD.
COVER ALL SIDES OF ALL TEL. &
ELEC. OUTLETS WITH 1/4" THICK
ACOUSTICAL SEALANT BEFORE
APPLYING GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON OPP.
SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE VA PARTITION # STUD SIZE
METAL STUD CHASE STUD SIZE SCHEDULE
M2A 09P22M2A 2 1/2"
M6A 09P62M6A 6"
M8A 09P82M8A 8"
M4A 09P42M4A 3 5/8"
AE601
C6
SimCEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
ATTACH DEFLECTION
TRACK TO STRUCTURE
AT 24" O.C. AND WITHIN
1" OF END. PROVIDE
3/4" DEFLECTION.
HEAD CONDITION
GWB PER
PARTITION TYPE
CONTINUOUS
ACOUSTICAL
JOINT SEALANT
ON BOTH SIDES
COPE GWB AROUND
BEAMS, BRIDGING,
PIPING, ETC.
PRECAST PLANK, SEE
STRUCT. DWGS.
8" NOM CMU BLOCK
CEILING AS
SCHEDULED SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS
CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
UNDERSIDE OF
PRECAST PLANK
/4
SLUSH CELLS 4"
DEEP MIN W/ GROUT
CONTINUOUS MINERAL WOOL
FIRESTOP INSULATION AND
FIREPROOF SEALANT
ELECTRICAL BOX
PLAN CONDITION
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
SEALANT BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.SCHEDULED BASE
BASE CONDITION
HEAD CONDITION
ATTACH RUNNERS TO FLOOR @
24" O.C. AND WITHIN 1" OF ENDS.
CONTINUOUS
ACOUSTICAL SEALANT
SCHEDULED FLOOR
ONE LAYER OF 5/8"
TYPE "X" GWB. ON ONE
SIDE OF 3 5/8" METAL
STUD @ 16" O.C.
UNFACED MINERAL-
FIBER BLANKET
INSULATION FRICTION
FIT FOR SOUND
DEADENING. SAME
THICKNESS AS WALL
STUD.
GYPSUM WALL BOARD
CEILING SYSTEM, SEE
SPEC. FOR MORE
INFORMATION
UL DESIGN: U906
SEE STRUCT. DWGS.
FOR ATTACHMENT
ONE LAYER OF 5/8" TYPE
"X" GWB. ON ONE SIDE
OF 7/8" METAL FURRING
@ 16" O.C. SEE
SCHEDULE FOR
FURRING SIZES.
CEILING AS
SCHEDULED SHOWN
SEE CEILING PLANS
FOR LOCATION AND
HEIGHTS
CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
UNDERSIDE OF
PRECAST PLANK
/4
SLUSH CELLS 4"
DEEP MIN W/ GROUT
CONTINUOUS MINERAL WOOL
FIRESTOP INSULATION AND
FIREPROOF SEALANT
ELECTRICAL BOX
PLAN CONDITION
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
SEALANT BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.SCHEDULED BASE
BASE CONDITION
HEAD CONDITION
ATTACH RUNNERS TO FLOOR @
24" O.C. AND WITHIN 1" OF ENDS.
CONTINUOUS
ACOUSTICAL SEALANT
SCHEDULED FLOOR
ONE LAYER OF 5/8"
TYPE "X" GWB. ON ONE
SIDE OF 3 5/8" METAL
STUD (6" METAL STUDS
AT FEC LOCATIONS) @
16" O.C.
MINERAL FIBER
INSULATION FRICTION FIT
FOR SOUND DEADENING.
SAME THICKNESS AS
WALL STUD.
GYPSUM WALL
BOARD CEILING
SYSTEM, SEE SPEC.
FOR MORE
INFORMATION.
8" NOM CMU BLOCK
UL DESIGN: U906
SEE STRUCT. DWGS.
FOR ATTACHMENT
CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
PORCELAIN TILE
BASE
BASE CONDITION
PLAN CONDITION
NEW PARTITION AS
SCHEDULED
5/8" CEMENTITIOUS
BACKER UNIT
NEW TILE FINISH,
REFER TO FINISH
SCHEDULE
CENTER OUTLETS IN TILE. COVER
ALL SIDES OF ALL TEL. & ELEC.
OUTLETS WITH 1/4" THICK
ACOUSTICAL SEALANT BEFORE
APPLYING GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON OPP.
SIDES OF PARTITIONS.
HEAD CONDITION
NOTE: MINIMUM SOUND TRANSMISSION CLASS RATING OF STC-49
BOTTOM OF SLAB
FLEXIBLE FIRESTOP
SEALANT
FIRE TRAK
5/8" TYPE "X" GWB
CUT TO FIT DECK
FLUTES
METAL STUD
HEAD CONDITION:
UL HW-D-0060
O V
E R
L A
P
UL DESIGN: U465 AT 1HR
PARTITIONS
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/3
/2
:0
:1
P
M U
A u to d e s k A u to s a v e s \R e v it \4
V A
M H
P R
O V
ID
E
N C
E M
H C
A
R C
H jo c e ly n
.b o o th e .r v t
AE601
650-332
NEW MENTAL HEALTH BUILDING -
PHASE 1
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB BRS10 APR 2019
CONSTRUCTION
DOCUMENTS
PARTITION TYPES AND DETAILS
FULLY SPRINKLERED
VA RI FACILITIES MANAGEMENT
SERVICE
3" = 1'-0"
F8 METAL STUD PARTITIONS - SOUND AND 1HR RATED
3" = 1'-0"
D8 METAL STUD CHASES
3" = 1'-0"
C6 TYPICAL METAL STUD HEAD CONDITION - SOUND
3" = 1'-0"
F5 C2 - 8" NOM CMU WALL - 3 5/8" CFMF ONE SIDE - 1HR
3" = 1'-0"
F3 C3 - 8" NOM CMU WALL - 3 5/8" CFMF ONE SIDE - 7/8 FURING
ON OTHER SIDE - 1HR
3" = 1'-0"
B8 TOILET ROOM WALLS W/ PORCELAIN TILE
3" = 1'-0"
C3 1HR PARTITION HEAD DETAIL
Revisions: Revision Description Date:
1 ADDENDUM 2 03 FEB 2020
| AE601 - PARTITION TYPES AND DETAILS - ADD 2.pdf |