36E77620R0001-0005065.pdf
PDF Posted
- Solicitation number
- 36E77620R0001
About this file
This document provides details for a federal construction contract opportunity with the Department of Veterans Affairs. The solicitation seeks bids for the construction of a new three-story mental health building on the Providence VA Medical Center campus in Providence, Rhode Island. The approximately 15,300 square foot freestanding building project includes site work, utilities infrastructure, and general construction activities. The solicitation will be advertised as a total Service-Disabled Veteran-Owned Small Business set-aside with an estimated value between $10-20 million. Responses are due on or around December 20th, 2019 according to the Federal Acquisition Regulation and a 600-day period of performance is anticipated.
36E77620R0001 0005 Attachment 2 - AE111 - FIRST FLOOR REFLECTED CEILING PLANS-ADD1.pdf
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
NM
S
S B
F
OS
OS
B
C
D
E
F
G
765431 2
TLT
TLT
TLT
HAC
COMPUTER LAB
STAIR 1
ELEV 1
ELEV 2
OFFICE
CORRIDOR
100A
CORRIDOR
100B
VESTIBULE
COMMUNICATION
CENTER
TOILET
CONSULT ROOM
RC CUBES
MEDICATION
ROOM
INJECTION ROOM
CONSULT ROOM
CONSULT ROOM
CONSULT ROOM
WAITING
CONSULT ROOM
STORAGE
OFFICE
9' - 6"
9' - 4"
8' - 0"
8' - 0"
8' - 0" 8' - 0"
8' - 0"
8' - 11"
1' - 0"26' - 0"21' - 0"21' - 0"21' - 0"23' - 0"10' - 0"
.0
9' - 4"
CORRIDOR
100B 19' - 0"
15' - 0"
8' - 4"
OFFICE
8' - 6"
8.7
SEGMENT B
SEGMENT A
SEGMENT B
SEGMENT A
SEGMENT B
SEGMENT A
8' - 6"
OFFICE
CUBICLES
C6
AE112
TYP
7' - 7 1/2"
7' - 7 1/2"
7' - 7 1/2"
7' - 7 1/2"
7' - 7 1/2"
7' - 7 1/2"
7' - 7 1/2"
C8
AE112
TYP
EQ EQ
7' - 7 1/2"
7' - 7 1/2"
ALIGN
C6
F1
AE520
Sim
MAIN
ELECTRICAL
ROOM
ALIGN
F7
AE605
B B B B
B
B
B
B
C3
C3
C3
B
B
B
B
B
B
ALIGN, TYP
A
EQ
EQ
B4
AE403
Sim
ALIGN
A L
IG
N
ALIGN
C8
AE112
TYP
F1
AE521
Sim F1
AE521
Sim
C3
B4
AE112
C1
AE112
C7
C7
AE608
B1
AE112
C8
C8
C9C9
D1
AE521
D6
AE521
N
N
N A
A
ALIGN
N
1 1
A
B
CONSULT ROOM -
EXTRA
STAIR 2
MEETING ROOM
1' - 0"
19' - 0"
15' - 0"
1' - 0 5/8"4' - 0"
8' - 0 1/8"
10' - 0"
8.7
C1
AE302
SEGMENT B
SEGMENT A
7' - 7 1/2"
7' - 7 1/2"
B
B
ALIGN, TYP
B
A
C8
AE112
TYP
F3
AE307
A
CEILING LEGEND
GWB CEILING @ 8'-0" AFF UNO
NOTES:
1. ALL CEILINGS TO BE 9'-0" AFF UNLESS NOTED
OTHERWISE
2. REFER TO SHEET GI002 FOR ALL ABBREVIATIONS
3. CONTRACTOR TO VERIFY LOCATIONS OF MAIN
CEILING TEES BEFORE PROCEEDING WITH FIXTURE
INSTALLATION. NOTIFY ARCHITECT OF
INTERFERENCES.
4. NOTIFY ARCHITECT OF ANY DISCREPANCIES
BETWEEN ARCHITECTURAL REFLECTED CEILING
PLANS AND ELECTRICAL LIGHTING PLANS PRIOR TO
CONSTRUCTION.
5. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF
STROBES AND EXIT SIGNS.
6. ALL CEILING GRILLES, TRIM EDGES AND SLOT
DIFFUSERS TO MATCH ADJACENT CEILING COLOR.
7. ALL SPRINKLER HEADS TO OCCUR AT CENTER OF
TILES.
8. LAYOUT TILES AS SHOWN IN REFLECTED CEILING
PLANS. CENTER GRID IN ROOM, UNO.
9. SEE AF SHEETS FOR ROOM FINISH SCHEDULE FOR
CEILING FINISH INFORMATION.
10. WHERE NO CEILING MATERIAL IS SHOWN THE
STRUCTURE ABOVE IS TO BE EXPOSED, U.N.O.
11. GENERAL LAYOUT AND SIZE OF LIGHT FIXTURES
ARE SHOWN.
ELECTRICAL SYMBOLS:
SYMBOLS INDICATE BASIS OF DESIGN LOCATIONS
MECHANICAL SYMBOLS:
SYMBOLS INDICATE BASIS OF DESIGN LOCATIONS
ACOUSTICAL TILE CEILING 2'-0" x 2'-0" ON
METAL SUSPENSION GRID @ 9'-0" AFF
UNO
RECESSED CEILING
FIXTURE
(EMERGENCY)
4' L CEILING/WALL
SURFACE STRIP LIGHT
SUPPLY
DIFFUSER
RETURN
GRILLE
SPECIALTY
PENDANT
INTERIOR
RECESSED
CAN
S
SMOKE
DETECTOR
FIRE PROTECTION SYMBOLS:
SYMBOLS DESIGNATE DESIGN INTENT, AND BASIS OF
DESIGN LOCATIONS . FINAL LAYOUT TO COMPLY
WITH ALL CODES AND REGULATIONS.
LAYOUT SHALL COMPLY W/ MEP BASIS OF DESIGN
DRAWINGS AND ALL CODES AND REGULATIONS.
EB
EMERGENCY
BATTERY PACK
EXIT SIGN
WOOD-LOOK PLANK CEILING. SEE PLAN
FOR LAYOUT. WD-1A FOR EXTERIOR,
WD-1B FOR INTERIOR
SPRINKLER
HEAD
EXHAUST
GRILLE
LINEAR DIFFUSER
A - ALIGN W/ GRID
B - CENTER ON GRID
SPEAKER
OS OCCUPANCY
SENSOR
N
CEILING MOUNT
NURSE CALL LIGHT
CEILING MOUNTED
CAMERA
RECESSED CEILING
FIXTURE
GLASSBREAKS
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/2
/2
:4
:1
A
M U
A u to d e s k A u to s a v e s \R e v it \4
V A
M H
P R
O V
ID
E
N C
E M
H C
A
R C
H m ic h a e l.
b ru n o .r v t
AE111
650-332
NEW MENTAL HEALTH BUILDING -
PHASE 1
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB ARW10 APR 2019
CONSTRUCTION
DOCUMENTS
FIRST FLOOR REFLECTED
CEILING PLANS
FULLY SPRINKLERED
VA RI FACILITIES MANAGEMENT
SERVICE
1/4" = 1'-0"
F1 FIRST FLOOR REFLECTED CEILING PLAN - SEGMENT A
1/4" = 1'-0"
C1 FIRST FLOOR REFLECTED CEILING PLAN - SEGMENT B
B
A
KEY PLAN
C3 START FULL CEILING TILE AGAINST
WALL / ELEMENT
C6 SOFFIT TO START AT CORNER
C7 COORDINATE TRIM PIECES FOR
LIGHTING AND DIFFUSERS IN METAL
CEILING. ITEMS TO OCCUR IN
SINGLE 6" PANEL.
C8 START FULL METAL PLANK AGAINST
WALL / ELEMENT
C9 ALIGN EXTERIOR METAL PANEL
WITH INTERIOR METAL PANEL
KEYNOTES
Revisions: Revision Description Date:
1 ADDENDUM 1 21 JAN 2020
| Sheets |
| AE110 - BASEMENT REFLECTED CEILING PLANS |
| AE111 - FIRST FLOOR REFLECTED CEILING PLANS |
| AE112 - SECOND FLOOR REFLECTED CEILING PLAN |
File details come from the government source that posted it. Updated .