This notice provides details for a forthcoming solicitation seeking construction services for a new mental health building project. The Department of Veterans Affairs intends to issue a Request for Proposal on or around December 20, 2019 for the design and construction of a new approximately 15,300 square foot freestanding three-story mental health building located at the Providence VA Medical Center campus in Providence, Rhode Island. Work will include general construction, site preparation including demolition, and corresponding utilities and infrastructure work. The period of performance is expected to be around 600 calendar days from notice to proceed. The solicitation will be set aside as a total Service-Disabled Veteran-Owned Small Business set-aside and have an anticipated value between $10-20 million. Questions must be submitted in writing by the stated deadline to the identified point of contact.
36E77620R0001 0005 Attachment 2 - EP1.0 - ELECTRICAL BASEMENT POWER PLAN-ADD1.pdf
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J J
NT
NT
N
N
J
J J
T V
2H
M
J
J
T V
2H
N T
N
DB
N
J
J
S S
S
S S
S
S S
S S
S
S
N D
S
J
J
N
DB
S
S
08' 4'
GRAPHIC SCALE
8' 16' 24'
SCALE: 1/8" = 1' - 0"
CONTRACTOR SHALL COORDINATE MOUNTING HEIGHT OF
ALL DEVICES WITH ARCHITECTS DRAWINGS PRIOR TO
ROUGH IN.
CIRCUIT NUMBERS ARE FOR DESCRIPTIVE PURPOSES ONLY.
EXACT NUMBERS SHALL BE DETERMINED IN FIELD AND
SHALL BE NOTED ON THE CONTRACTORS AS-BUILT
DRAWINGS.
BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED AND
INSTALLED FOR A MAXIMUM BRANCH CIRCUIT VOLTAGE
DROP OF 3% FROM PANELBOARD. TOTAL VOLTAGE DROP
FROM SERVICE ENTRY TO LAST DEVICE ON CIRCUIT SHALL
NOT EXCEED 5%. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS AND OPTIONS.
POWER PLAN NOTES
COORDINATE EXACT LOCATIONS OF ALL MECHANICAL
EQUIPMENT WITH HVAC, PLUMBING, AND FIRE PROTECTION
DRAWINGS.
ALL RECEPTACLES WITHIN 6' OF A SINK SHALL BE PROVIDED
WITH GFCI PROTECTION.
ALL RECEPTACLES IN SPACES DESIGNATED AS "WAITING
ROOM" SHALL BE TAMPERPROOF.
1.
2.
3.
4.
5.
6.
POWER PLAN KEYED NOTES
1 PROVIDE 2#12, 1#12G FOR ELECTRIC DOOR HARDWARE.
DOOR HARDWARE FURNISHED BY OTHERS.
2 UTILITY CONDUITS TO STUB UP THROUGH CHASE. ENTIRE
INTERIOR RUN OF CONDUITS SHALL BE ENCASED IN 3" OF
CONCRETE. SEE CONDUIT ENTRANCE DETAIL ON DRAWING
EK1.0. COORDINATE ROUTING WITH STRUCTURAL ENGINEER
TO AVOID STRUCTURAL FOOTINGS.
3 PROVIDE BOGEN PA SYSTEM HEAD-END. HEAD-END UNIT
SHALL BE MOUNTED IN RACK.
4 PROVIDE 2.2KVA APC SMART UPS WITH MANAGEMENT CARD.
THE BASIS OF DESIGN FOR THE ELEVATOR IS A 20HP
THYSEENKRUPP TRACTION ELEVATOR. CONTRACTOR SHALL
NOTIFY ARCHITECT AND ENGINEER IF MOTOR HORSEPOWER
IS DIFFERENT THAN BASIS OF DESIGN.
7.
CUH-38-0-01
CR411 CR211T5
CLASSROOM
CLASSROOM
CLASSROOM STORAGE
027A
STAFF TOILET
EMERG. ELECT.
018A
TELE/ DATA
ELECTRICAL
OFFICE
OCCUPATIONAL THERAPY ROOM
016CORRIDOR
OT OFFICE
OFFICE
OFFICE
PRRC CUBES
TOILET
TOILET
ELEV. CONTROL ROOM
CONSULT ROOM
CONSULT ROOM
CONSULT ROOM - EXTRA
WATER SERVICE
ELEV 2
ELEV 1
WAITING
ELEVATOR LOBBY
STAIR 1
AC-38-1-02
C
C
REF
C
C C
C
C
C C
C
PROJECTOR
PROJECTOR
- 6,8NP211 - 5,7NP211
- 2,4NP211
- 1,3NP211
- 1CR211
ELEV-1
ELEV #2 LTS
C
C
NP211
C
D
E
F
G
76543 1 2
8.7
- 10NP211
10 10
- 11NP211
11 11
- 12NP211
- 13NP211
- 14NP211
- 15NP211
- 16NP211
- 19NP211
- 18NP211
18 18
- 20NP211
- 21NP211
- 22NP211
- 23NP211
23 23 23
- 24NP211
- 25NP211
- 26NP211
- 27NP211
-CR211 12
- 28NP211
- 29NP211
- 30NP211
-CR211 11
- 34NP211
WATER
FOUNTAIN
POWER
/2 EP1.0
/2 EP1.0
ATCATC
- 35NP211
- 37NP211
CAMERA
- 10CR211
- 39,41NP211
NEMA 6 - 40R
WP
C
C
STORAGE
- 3CR211
CAM CAM
ELEV-2
ELEV #1 LTS
CLASSROOM STORAGE
027B
OVEN
SP-1
- 42NP211
SP-1
- 9NP211
KH-1
- 45NP211
SCREEN
SCREEN
- 46NP211
WAP
WAP
MC
HAC
- 48NP211
- 38NP211
- 1,3,5CR411
- 8,10,12CR411
UPS
UPS
- 6CR211
- 4CR211
SECURITY
HEAD-END
UNIT
1 1 1
1 1
11 1
- 31NP211
- 49NP211
CUH-38-0-02
STAIR 2
CORRIDOR
STAFF TOILET
STAFF LOUNGE
032C
REF
C
C
USB
USB
- 3,5,7NP221
C
A
B
8.7
- 32NP211
- 33NP21133
/1 EP1.0
/1 EP1.0
- 36NP211
- 4MDP
- 5MDP
CH-38-0-02
CH-38-0-01
MC
- 47NP211
SCREEN
- 31NP211
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH VA RI FACILITIES MANAGEMENT
SERVICE
Approved:
FULLY SPRINKLERED
NEW MENTAL HEALTH
BUILDING 38 - PHASE 1
830 CHALKSTONE AVE PROVIDENCE, RI 02908
650-332
Engineering Discipline:
/2
/2
:5
:5
P
M C
U s e rs
\r q u ie to
\D o c u m e n ts
\1
.0
-V A
M C
P ro v id e n c e
M e n ta l H e a lt h
B ld g
C e n tr a l( rq u ie to
.r v t
EP1.0
KT BG10 APR 2019
CONSTRUCTION
DOCUMENTS
ELECTRICAL - BASEMENT -
POWER PLAN
1/4" = 1'-0"EP1.0
1 ELECTRICAL - BASEMENT - POWER PLAN - PART A
1/4" = 1'-0"EP1.0
2 ELECTRICAL - BASEMENT - POWER PLAN - PART B