36E77620R0001-0005067.pdf

PDF Posted

Attached to
650-332 New Mental Health Building - Phase 1 (VA-19-00104660)
Solicitation number
36E77620R0001
Issued by

About this file

This notice provides details for a forthcoming solicitation seeking construction services for a new mental health building project. The Department of Veterans Affairs intends to issue a Request for Proposal on or around December 20, 2019 for the design and construction of a new approximately 15,300 square foot freestanding three-story mental health building located at the Providence VA Medical Center campus in Providence, Rhode Island. Work will include general construction, site preparation including demolition, and corresponding utilities and infrastructure work. The period of performance is expected to be around 600 calendar days from notice to proceed. The solicitation will be set aside as a total Service-Disabled Veteran-Owned Small Business set-aside and have an anticipated value between $10-20 million. Questions must be submitted in writing by the stated deadline to the identified point of contact.

36E77620R0001 0005 Attachment 2 - EP1.0 - ELECTRICAL BASEMENT POWER PLAN-ADD1.pdf

View the file

Other files

File Type Posted
36E77620R0001-0007000.docx DOCX document
36E77620R0001-0007001.docx DOCX document
36E77620R0001-0006000.docx DOCX document
36E77620R0001-0005060.docx DOCX document
36E77620R0001-0005061.docx DOCX document
36E77620R0001-0005068.pdf PDF
36E77620R0001-0005064.pdf PDF
36E77620R0001-0005069.pdf PDF
36E77620R0001-0005062.pdf PDF
36E77620R0001-0005070.pdf PDF
36E77620R0001-0005066.pdf PDF
36E77620R0001-0005065.pdf PDF
36E77620R0001-0005063.pdf PDF
36E77620R0001-0005071.pdf PDF
36E77620R0001-0004001.docx DOCX document
36E77620R0001-0004000.docx DOCX document
36E77620R0001-0003000.docx DOCX document
36E77620R0001-0003001.docx DOCX document
36E77620R0001-0002000.docx DOCX document
36E77620R0001-0001001.pdf PDF
36E77620R0001-0001000.docx DOCX document
36E77620R0001-008.pdf PDF
36E77620R0001-007.pdf PDF
36E77620R0001-012.pdf PDF
36E77620R0001-016.docx DOCX document
36E77620R0001-001.docx DOCX document
36E77620R0001-004.pdf PDF
36E77620R0001-005.pdf PDF
36E77620R0001-006.pdf PDF
36E77620R0001-010.pdf PDF
36E77620R0001-013.pdf PDF
36E77620R0001-015.docx DOCX document
36E77620R0001-017.pdf PDF
36E77620R0001-002.pdf PDF
36E77620R0001-011.pdf PDF
36E77620R0001-014.pdf PDF
36E77620R0001-009.pdf PDF
36E77620R0001-003.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J J

NT

NT

N

N

J

J J

T V

2H

M

J

J

T V

2H

N T

N

DB

N

J

J

S S

S

S S

S

S S

S S

S

S

N D

S

J

J

N

DB

S

S

08' 4'

GRAPHIC SCALE

8' 16' 24'

SCALE: 1/8" = 1' - 0"

CONTRACTOR SHALL COORDINATE MOUNTING HEIGHT OF

ALL DEVICES WITH ARCHITECTS DRAWINGS PRIOR TO

ROUGH IN.

CIRCUIT NUMBERS ARE FOR DESCRIPTIVE PURPOSES ONLY.

EXACT NUMBERS SHALL BE DETERMINED IN FIELD AND

SHALL BE NOTED ON THE CONTRACTORS AS-BUILT

DRAWINGS.

BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED AND

INSTALLED FOR A MAXIMUM BRANCH CIRCUIT VOLTAGE

DROP OF 3% FROM PANELBOARD. TOTAL VOLTAGE DROP

FROM SERVICE ENTRY TO LAST DEVICE ON CIRCUIT SHALL

NOT EXCEED 5%. REFER TO SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS AND OPTIONS.

POWER PLAN NOTES

COORDINATE EXACT LOCATIONS OF ALL MECHANICAL

EQUIPMENT WITH HVAC, PLUMBING, AND FIRE PROTECTION

DRAWINGS.

ALL RECEPTACLES WITHIN 6' OF A SINK SHALL BE PROVIDED

WITH GFCI PROTECTION.

ALL RECEPTACLES IN SPACES DESIGNATED AS "WAITING

ROOM" SHALL BE TAMPERPROOF.

1.

2.

3.

4.

5.

6.

POWER PLAN KEYED NOTES

1 PROVIDE 2#12, 1#12G FOR ELECTRIC DOOR HARDWARE.

DOOR HARDWARE FURNISHED BY OTHERS.

2 UTILITY CONDUITS TO STUB UP THROUGH CHASE. ENTIRE

INTERIOR RUN OF CONDUITS SHALL BE ENCASED IN 3" OF

CONCRETE. SEE CONDUIT ENTRANCE DETAIL ON DRAWING

EK1.0. COORDINATE ROUTING WITH STRUCTURAL ENGINEER

TO AVOID STRUCTURAL FOOTINGS.

3 PROVIDE BOGEN PA SYSTEM HEAD-END. HEAD-END UNIT

SHALL BE MOUNTED IN RACK.

4 PROVIDE 2.2KVA APC SMART UPS WITH MANAGEMENT CARD.

THE BASIS OF DESIGN FOR THE ELEVATOR IS A 20HP

THYSEENKRUPP TRACTION ELEVATOR. CONTRACTOR SHALL

NOTIFY ARCHITECT AND ENGINEER IF MOTOR HORSEPOWER

IS DIFFERENT THAN BASIS OF DESIGN.

7.

CUH-38-0-01

CR411 CR211T5

CLASSROOM

CLASSROOM

CLASSROOM STORAGE

027A

STAFF TOILET

EMERG. ELECT.

018A

TELE/ DATA

ELECTRICAL

OFFICE

OCCUPATIONAL THERAPY ROOM

016CORRIDOR

OT OFFICE

OFFICE

OFFICE

PRRC CUBES

TOILET

TOILET

ELEV. CONTROL ROOM

CONSULT ROOM

CONSULT ROOM

CONSULT ROOM - EXTRA

WATER SERVICE

ELEV 2

ELEV 1

WAITING

ELEVATOR LOBBY

STAIR 1

AC-38-1-02

C

C

REF

C

C C

C

C

C C

C

PROJECTOR

PROJECTOR

- 6,8NP211 - 5,7NP211

- 2,4NP211

- 1,3NP211

- 1CR211

ELEV-1

ELEV #2 LTS

C

C

NP211

C

D

E

F

G

76543 1 2

8.7

- 10NP211

10 10

- 11NP211

11 11

- 12NP211

- 13NP211

- 14NP211

- 15NP211

- 16NP211

- 19NP211

- 18NP211

18 18

- 20NP211

- 21NP211

- 22NP211

- 23NP211

23 23 23

- 24NP211

- 25NP211

- 26NP211

- 27NP211

-CR211 12

- 28NP211

- 29NP211

- 30NP211

-CR211 11

- 34NP211

WATER

FOUNTAIN

POWER

/2 EP1.0

/2 EP1.0

ATCATC

- 35NP211

- 37NP211

CAMERA

- 10CR211

- 39,41NP211

NEMA 6 - 40R

WP

C

C

STORAGE

- 3CR211

CAM CAM

ELEV-2

ELEV #1 LTS

CLASSROOM STORAGE

027B

OVEN

SP-1

- 42NP211

SP-1

- 9NP211

KH-1

- 45NP211

SCREEN

SCREEN

- 46NP211

WAP

WAP

MC

HAC

- 48NP211

- 38NP211

- 1,3,5CR411

- 8,10,12CR411

UPS

UPS

- 6CR211

- 4CR211

SECURITY

HEAD-END

UNIT

1 1 1

1 1

11 1

- 31NP211

- 49NP211

CUH-38-0-02

STAIR 2

CORRIDOR

STAFF TOILET

STAFF LOUNGE

032C

REF

C

C

USB

USB

- 3,5,7NP221

C

A

B

8.7

- 32NP211

- 33NP21133

/1 EP1.0

/1 EP1.0

- 36NP211

- 4MDP

- 5MDP

CH-38-0-02

CH-38-0-01

MC

- 47NP211

SCREEN

- 31NP211

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH VA RI FACILITIES MANAGEMENT

SERVICE

Approved:

FULLY SPRINKLERED

NEW MENTAL HEALTH

BUILDING 38 - PHASE 1

830 CHALKSTONE AVE PROVIDENCE, RI 02908

650-332

Engineering Discipline:

/2

/2

:5

:5

P

M C

U s e rs

\r q u ie to

\D o c u m e n ts

\1

.0

-V A

M C

P ro v id e n c e

M e n ta l H e a lt h

B ld g

C e n tr a l( rq u ie to

.r v t

EP1.0

KT BG10 APR 2019

CONSTRUCTION

DOCUMENTS

ELECTRICAL - BASEMENT -

POWER PLAN

1/4" = 1'-0"EP1.0

1 ELECTRICAL - BASEMENT - POWER PLAN - PART A

1/4" = 1'-0"EP1.0

2 ELECTRICAL - BASEMENT - POWER PLAN - PART B

Revisions: Date:

1 01/21/2020

S T

A

T E

O F

R H O D

E

I S L A

N D

HOPE

01/21/2020

File details come from the government source that posted it. Updated .