36E77620R0001-0005068.pdf
PDF Posted
- Solicitation number
- 36E77620R0001
About this file
This notice provides details for an upcoming federal construction contract opportunity for a New Mental Health Building project located in Providence, Rhode Island. The Department of Veterans Affairs will solicit bids and award a firm-fixed-price contract for general construction and site work including demolition, utilities, and the construction of a new approximately 15,300 square foot freestanding three-story mental health building. The total period of performance is expected to be approximately 600 calendar days from notice to proceed with a construction magnitude estimated between $10,000,000 to $20,000,000. The solicitation will be set aside entirely for Service-Disabled Veteran-Owned Small Businesses and issued on or about December 20, 2019 as a Request for Proposal conducted according to the Federal Acquisition Regulation. Questions must be submitted in writing by the specified deadline.
36E77620R0001 0005 Attachment 2 - EP1.1 - ELECTRICAL FIRST FLOOR POWER PLAN-ADD1.pdf
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JJ
N
N
N
N T
NT
NT
NM
S
S B
JJ
J
TV2
H
J
N T
J
N
S S S
S
S
S
S S
S
S
S
S
J
J
S
S
CONTRACTOR SHALL COORDINATE MOUNTING HEIGHT OF
ALL DEVICES WITH ARCHITECTS DRAWINGS PRIOR TO
ROUGH IN.
CIRCUIT NUMBERS ARE FOR DESCRIPTIVE PURPOSES ONLY.
EXACT NUMBERS SHALL BE DETERMINED IN FIELD AND
SHALL BE NOTED ON THE CONTRACTORS AS-BUILT
DRAWINGS.
BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED AND
INSTALLED FOR A MAXIMUM BRANCH CIRCUIT VOLTAGE
DROP OF 3% FROM PANELBOARD. TOTAL VOLTAGE DROP
FROM SERVICE ENTRY TO LAST DEVICE ON CIRCUIT SHALL
NOT EXCEED 5%. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS AND OPTIONS.
POWER PLAN NOTES
COORDINATE EXACT LOCATIONS OF ALL MECHANICAL
EQUIPMENT WITH HVAC, PLUMBING, AND FIRE PROTECTION
DRAWINGS.
ALL RECEPTACLES WITHIN 6' OF A SINK SHALL BE PROVIDED
WITH GFCI PROTECTION.
ALL RECEPTACLES IN SPACES DESIGNATED AS "WAITING
ROOM" SHALL BE TAMPERPROOF.
1.
2.
3.
4.
5.
6.
POWER PLAN KEYED NOTES
1 PROVIDE 2#12, 1#12G FOR ELECTRIC DOOR HARDWARE.
DOOR HARDWARE FURNISHED BY OTHERS.
OFFICE
OFFICE
CUBICLES
CONSULT ROOM
CONSULT ROOM
INJECTION ROOM
MEDICATION ROOM
CONSULT ROOM
TOILET
STORAGE
CORRIDOR
100B
COMPUTER LAB
OFFICE
OFFICE
112RC CUBES
TLT
TLT
CORRIDOR
100A
COMMUNICATION CENTER
CONSULT ROOM
SECURITY / WC STORAGE
101AVESTIBULE
WAITING
STAIR 1
ELEV 1
ELEV 2
HAC
TLT
C C
WP
C
D
E
F
G
76543 1 2
8.7
- 11NP221
- 13NP221
- 14NP221
14 14
- 16NP221 16 16
- 15NP221
- 17NP221
- 18NP221
- 19NP221
- 21NP221
- 20NP221
21 21
- 22NP221
- 23NP221
- 28NP221
- 29NP221
- 30NP221
- 31NP221
- 32NP221
- 33NP221
- 37NP221
- 38NP221
- 39NP221
WATER FOUNTAIN POWER
/2 EP1.1
/2 EP1.1
ATC ATC
- 41NP221
C
C C
C C C
16 16 16
- 24NP221
24 24 24
252525
26 26 26
- 26NP221
- 25NP221
- 27NP221
CAMCAM
CAM
NP221
MAIN ELECTRICAL ROOM
NP421
T8
CONSULT ROOM
- 43NP221
- 45NP221
- 2CR211
C
- 46NP221
- 9NP221
- 48NP221
ADO
C
- 5CR211
- 7CR211
C
REF
ADO PUSH
BUTTON (TYP) CUH-38-1-01
- 1NP221
WIRELESS ADO
C
FACP
1 1
1 1
- 40NP221
STAIR 2
CONSULT ROOM - EXTRA
WP
A
B
8.7
- 34NP221
/1 EP1.1
/1 EP1.1
- 42NP221
- 36NP221
CAM
- 35NP221
MEETING ROOM
- 44NP221
GRAPHIC SCALE
4' 2' 0 4' 8' 12'
SCALE: 1/4" = 1' - 0"
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH VA RI FACILITIES MANAGEMENT
SERVICE
Approved:
FULLY SPRINKLERED
NEW MENTAL HEALTH
BUILDING 38 - PHASE 1
830 CHALKSTONE AVE PROVIDENCE, RI 02908
650-332
Engineering Discipline:
/2
/2
:0
:0
P
M C
U s e rs
\r q u ie to
\D o c u m e n ts
\1
.0
-V A
M C
P ro v id e n c e
M e n ta l H e a lt h
B ld g
C e n tr a l( rq u ie to
.r v t
EP1.1
KT BG10 APR 2019
CONSTRUCTION
DOCUMENTS
ELECTRICAL - FIRST FLOOR -
POWER PLAN
1/4" = 1'-0"EP1.1
1 ELECTRICAL - FIRST FLOOR - POWER PLAN - PART A
1/4" = 1'-0"EP1.1
2 ELECTRICAL - FIRST FLOOR - POWER PLAN - PART B
Revisions: Date:
1 01/21/2020
S T
A
T E
O F
R H O D
E
I S L A
N D
HOPE
01/21/2020
File details come from the government source that posted it. Updated .