0009 14.0_SNC- Phase 1B-Irrigation As-Builts_Combined.pdf
PDF 11 MB Posted
- Solicitation number
- 36C78625R50086
About this file
This document consists of irrigation system design plans and technical specifications for a cemetery facility. The plans were prepared by a consulting firm specializing in architecture, engineering, planning, and the environment, with offices in Sacramento, California.
The irrigation system design includes seven independent controller zones (labeled A through G) distributed across the cemetery grounds, each managing designated burial and landscaped areas marked with section identifiers and numerical flow rates. The system incorporates a central control unit (CCU) housed in a maintenance building, connected via 1-1/4" PVC conduit to satellite field controllers. Key infrastructure components include a pump station and filter location, pond water intake, irrigation mainline distribution network, and phase one implementation limited to specific work boundaries. Technical specifications address valve placement, electrical control systems, flow metering, pop-up sprinkler head installation, burial line routing through aisles between headstone groups, and various operational constraints such as prohibitions on locating quick coupler valves or remote control valves in roadways. The detailed plans show irrigation scheduling tables for each controller zone, pipe sizing guides, drainage fill requirements for valve boxes, and installation standards for components including ball valves, electrical control valves, flow sensors, and master valve assemblies. Construction notes emphasize proper depth for underground piping, wire protection under pavement, valve box placement relative to structures, and compliance with specified spacing and clearance requirements throughout the irrigated landscape areas.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LI
M
IT
O
F
IR
R
IG
AT
IO
N
LIMIT OF WORK
LIMIT OF IRRIGATION
a10 215 a7 a15 a6 a5 c2 a9 a8 a11 a13 a14 a28 c1 137 c3 c4 c5 b12 a22 a16 a17 a18 a19 a20 a21 a4 a3 a12 a26 a23 a27 a24 a1 a2 b3 a25 a29
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-4
NORTH
GRAPHIC SCALE: 1" = 40'
C O
N
TR
O
LL
ER
b
SE
E
SH
EE
T
I-5
CONTROLLER c - SEE SHEET I-6
CONTROLLER a
LOCATION
COMMUNICATION CABLE
CONNECTING THE CCU LOCATED
AT THE MAINTENANCE BUILDING
TO THE FIELD CONTROLLERS IN
PHASE ONE. SEE ELECTRICAL
SHEET L-E1 FOR ROUTING.
NOTE: DRAWINGS ARE DIAGRAMMATIC:
1. ALL MAIN LINES RUNNING THROUGH BURIAL SECTIONS
ARE TO BE PLACED IN THE AISLE/EMPTY ROW. THE ROTOR
HEADS ARE TO BE CENTERED IN AISLE BETWEEN GROUPS
OF 4 HEADSTONES, SEE DIAGRAM ON DETAIL SHEET I-11.
2. THERE SHALL BE NO QUICK COUPLER VALVES OR
REMOTE CONTROL VALVES LOCATED IN THE ROADWAYS.
LIMIT OF WORK
c2 c1 137 c3 c4 c5 b13 b12 b11 b2 b1 b4 b25 b24 b23 b22 b21 b26 b27 b28 b29 b18 b19 b17 b15 d10 d11 b16 d16 b6 b7 b8 b9 b10 a21 b14 b20 d9 b3 d1 b5
LIM
IT O
F IR
R
IG
A
TIO
N
MIDWAY ROAD
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-5
NORTH
GRAPHIC SCALE: 1" = 40'
C O
N
TR
O
LL
ER
a
SE
E
SH
EE
T
I-4
CONTROLLER d - SEE SHEET I-6
CONTROLLER b
LOCATION
NOTE: DRAWINGS ARE DIAGRAMMATIC:
1. ALL MAIN LINES RUNNING THROUGH BURIAL SECTIONS
ARE TO BE PLACED IN THE AISLE/EMPTY ROW. THE ROTOR
HEADS ARE TO BE CENTERED IN AISLE BETWEEN GROUPS
OF 4 HEADSTONES, SEE DIAGRAM ON DETAIL SHEET I-11.
2. THERE SHALL BE NO QUICK COUPLER VALVES OR
CONTROLLER c - SEE SHEET I-6
IT
O
F W
O R
K c2 a28 c1 137 c3 c4 c5 c7 c8 c11 198 c10 c9 c13 c14 c12 c6 b13 c30 c28 c29 c27 c26 d6 d5 c23 c22 b14 d2 d4 c24 c18 c17 c25 c16 a26 a27 c15 c20 c21 a25 c19 d3 d1
LI
M
IT
O
F
IR
R
IG
AT
IO
N
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-6
NORTH
GRAPHIC SCALE: 1" = 40'
C
O N
TR
O
LL
ER
d
SE
E
SH
EE
T I-7
CONTROLLER b - SEE SHEET I-5
CONTROLLER c
LOCATION
MATCHLINE - SEE SHEET I-7
CO
NT
RO
LL
ER
a
S
EE
S
HE
ET
I-
NOTE: DRAWINGS ARE DIAGRAMMATIC:
1. ALL MAIN LINES RUNNING THROUGH BURIAL SECTIONS
ARE TO BE PLACED IN THE AISLE/EMPTY ROW. THE ROTOR
HEADS ARE TO BE CENTERED IN AISLE BETWEEN GROUPS
OF 4 HEADSTONES, SEE DIAGRAM ON DETAIL SHEET I-11.
LIM
IT OF W
ORK
c7 c8 c9 c6 b15 d10 d11 d7 d16 d18 d22 e2 b8 b9 b10 e12 123 e13
173 e14 e16 e18 e15 d24 d23 d25 d27 d6 d5 b14 d2 d4 d26 d9 d14 d28 e1 d15 d29 c20 c21 d8 e17 c19 d3 d1 d12 d13 d17 d19 d20 d21 e6 e3 e5
LIM
IT O
F IRRIG
ATIO
N
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-7
NORTH
GRAPHIC SCALE: 1" = 40'
C O
N
TR
O
LL
ER
c
SE
E
SH
EE
T
I-6
CONTROLLER e - S
EE SHEET I-8
CONTROLLER b - SEE SHEET I-5
NOTE: DRAWINGS ARE DIAGRAMATIC:
1. ALL MAIN LINES RUNNING THROUGH BURIAL SECTIONS
ARE TO BE PLACED IN THE AISLE/EMPTY ROW. THE ROTOR
HEADS ARE TO BE CENTERED IN AISLE BETWEEN GROUPS
OF 4 HEADSTONES, SEE DIAGRAM ON DETAIL SHEET I-11.
2. THERE SHALL BE NO QUICK COUPLER VALVES OR
REMOTE CONTROL VALVES LOCATED IN THE ROADWAYS.
CONTROLLER d
LOCATION
LIM
IT OF W
ORK
LIM
IT OF W
ORK
e2 e11 e24 e23 e22 e21 e26 e28 e27 e30 e12 123 e13
173 e14 e16 e18 e15 d24 d23 d25 d26 f 3 f 2 f 4 e25 e31 e29 e1 e20 e19 d29 c20 c21 e17 g2 89 g1 d21 e6 e7 e8 e9 e10 e3 e4 e5
LI
M
IT
O
F
IR
RI
GAT
IO
N
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-8
NORTH
GRAPHIC SCALE: 1" = 40'
C O
N
TR
O
LL
ER
g
SE
E
SH
EE
T
I-1
CONTROLLER d - SEE SHEET I-7
CONTROLLER e
LOCATION
CONTROLLER f - SEE SHEET I-9
NOTE: DRAWINGS ARE DIAGRAMMATIC:
1. ALL MAIN LINES RUNNING THROUGH BURIAL SECTIONS
ARE TO BE PLACED IN THE AISLE/EMPTY ROW. THE ROTOR
HEADS ARE TO BE CENTERED IN AISLE BETWEEN GROUPS
OF 4 HEADSTONES, SEE DIAGRAM ON DETAIL SHEET I-11.
f 1 g14 g15 f13 f 6 f 7 e26 e28 e27 e30 f15 f 3 f 2 f 4 e25 f 8 e31 e29 f14 f10 f12 f11 f17 f16 f 5 f 9
LI
M
IT
O
F
IR
RI
GAT
IO
N
LIMIT OF IRRIGATION
I-9
NORTH
GRAPHIC SCALE: 1" = 40'
CONTROLLER e - SEE SHEET I-8
CONTROLLER f
LOCATION
C O
N
TR
O
LL
ER
g
SE
E
SH
EE
T
I-1
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
NOTE: DRAWINGS ARE DIAGRAMMATIC:
1. ALL MAIN LINES RUNNING THROUGH BURIAL SECTIONS
ARE TO BE PLACED IN THE AISLE/EMPTY ROW. THE ROTOR
HEADS ARE TO BE CENTERED IN AISLE BETWEEN GROUPS
OF 4 HEADSTONES, SEE DIAGRAM ON DETAIL SHEET I-11.
IT
O
F W
O R
K
LIMIT OF IRRIGATION
g9 g8 g6 g5 g4 g3 f 1 g11 g13 g14 g15 f 6 f 7 e24 e23 e22 e21 e12 123 e13
173 e14 e16 e18 e15 c23 f 3 f 2 f 4 c24 f 8 f 5 c25 e20 e19 g12 f e17 g2 89 g1 g7 g10
LIMIT OF IRRIGATION
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-10
NORTH
GRAPHIC SCALE: 1" = 40'
CONTROLLER c - SEE SHEET I-6
CONTROLLER g
LOCATION
C O
N
TR
O
LL
ER
f
- S
EE
S H
EE
T
I-9
NOTE: DRAWINGS ARE DIAGRAMMATIC:
1. ALL MAIN LINES RUNNING THROUGH BURIAL SECTIONS
ARE TO BE PLACED IN THE AISLE/EMPTY ROW. THE ROTOR
HEADS ARE TO BE CENTERED IN AISLE BETWEEN GROUPS
OF 4 HEADSTONES, SEE DIAGRAM ON DETAIL SHEET I-11.
2. THERE SHALL BE NO QUICK COUPLER VALVES OR
REMOTE CONTROL VALVES LOCATED IN THE ROADWAYS.
C O
N
TR
O
LL
ER
e
SE
E
SH
EE
T
I-8
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-1 c1
CCC
a g d b c e f
FS
PUMP
b c df a c h a g e h
IT
O
F
IR
RI
G
AT
IO
N
LIMIT OF WORK
LI
M
IT
O
F W
O R
K
LIMIT OF IRRIGATION
LIMIT OF WORK
LIM
IT OF W
ORK
LIM
IT OF W
ORK
LIM
IT OF W
ORK
LIM
IT O
F W O
RK
a10 215 a7 a15 a6 a5 c2 a9 a8 a11 a13 a14 a28 c1 137 c3 c4 c5 c7 c8 c11 198 c10 c9 c13 c14 c12 c6 b13 b12 b11 a22 a16 a17 a18 a19 a20 124 b2 b1 b4 b25 b24 b23 b22 b21 b26 b27 b28 b29 b18 b19 b17 b15 d10 d11 b16 d7 d16 d18 d22 e2 e11 b6 b7 b8 b9 b10 a21 a4 a3 c30 c28 c29 c27 c26 g9 g8 g6 g5 g4 g3 f 1 g11 g13 g14 g15 f13 f 6 f 7 e24 e23 e22 e21 e26 e28 e27 e30 e12 123 e13
173 e14 e16 e18 e15 d24 d23 d25 d27 d6 d5 f15 c23 c22 b14 d2 d4 d26 f 3 f 2 f 4 b20 c24 c18 c17 d9 d14 e25 f 8 e31 e29 d28 e1 f14 f10 f12 f11 f17 f16 d15 f 5 c25 a12 c16 e20 e19 d29 g12 a26 a23 a27 a24 a1 a2 b3 c15 c20 c21 d8 f 9 e17 a25 g2 89 g1 c19 d3 d1 d12 d13 g7 a29 b5 d17 d19 d20 d21 e6 e7 e8 e9 e10 g10 e3 e4 e5
LI
M
IT
O
F
IR
RI
GAT
IO
N
LIMIT OF IRRIGATION
LIM
IT O
F IRRIG
ATIO
N
LIMIT OF IRRIGATION
LI
M
IT
O
F
IR
R
IG
AT
IO
N
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-2
NORTH
GRAPHIC SCALE: 1" = 100'
MAINTENANCE FACILITY
LIMIT OF IRRIGATED LANDSCAPE
CONTROLLER c
LOCATION
CONTROLLER CCU g
LOCATION
CONTROLLER b
LOCATION
CONTROLLER f
LOCATION
FUTURE
CONTROLLER h
LOCATION
PUMP
STATION &
FILTER
LOCATION
CONTROLLER e
LOCATION
CONTROLLER a
LOCATION
CONTROLLER d
LOCATION
CCC LOCATED IN
MAINTENANCE
BUILDING
COMMUNICATION CABLE IN A
1-1/4" PVC CONDUIT,
CONNECT TO CCU
CONTROLER g AND ALL
SUBSEQUENT SATELLITE
CONTROLLERS IN PHASE 1
PHASE 1/LIMIT OF WORK
a10 215 a7 a15 a6 a5 c2 a9 a8 a11 a13 a14 a28 c1 137 c3 c4 c5 c7 c8 c11 198 c10 c9 c13 c14 c12 c6 b13 b12 b11 a22 a16 a17 a18 a19 a20 124 b2 b1 b4 b25 b24 b23 b22 b21 b26 b27 b28 b29 b18 b19 b17 b15 d10 d11 b16 d7 d16 d18 d22 e2 e11 b6 b7 b8 b9 b10 a21 a4 a3 c30 c28 c29 c27 c26 g9 g8 g6 g5 g4 g3 g11 g13 g14 g15 e24 e23 e22 e21 e26 e28 e27 e30 e12 123 e13
173 e14 e16 e18 e15 d24 d23 d25 d27 d6 d5 c23 c22 b14 d2 d4 d26 b20 c24 c18 c17 d9 d14 e25 e31 e29 d28 e1 d15 c25 a12 c16 e20 e19 d29 g12 a26 a23 a27 a24 a1 a2 b3 c15 c20 c21 d8 e17 a25 g2 89 g1 c19 d3 d1 d12 d13 g7 a29 b5 d17 d19 d20 d21 e6 e7 e8 e9 e10 g10 e3 e4 e5
MIDWAY ROAD
Consultants in Architecture, Engineering, Planning, and the Environment
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-3
NORTH
GRAPHIC SCALE: 1" = 100'
PHASE 1/LIMIT OF WORK
LIMIT OF IRRIGATED LANDSCAPE
PUMP
STATION &
FILTER
LOCATION
IRRIGATION MAINLINE
POND
UPTAKE
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-11
SCH 80 PVC UNION
DOWNSTREAM OF VALVE
SCH 40 PVC MALE ADAPTOR
FIPT x SLIP, TYP (2) PLACES
OF VALVE BOW.
6. REFER TO SPECIFICATIONS AND PLAN SHEETS FOR
MORE INFORMATION.
1. INSTALL VALVES A MIN. OF 12" FROM
STRUCTURES OR HARDSCAPING
2. INSTALL VALVES IN PLANTING BEDS WHEREVER POSSIBLE
3. PLACE VALVE BOX AT RIGHT ANGLES TO STRUCTURES
4. INSTALL VALVE BOX SO THAT TOP OF VALVE BOX IS
FLUSH WITH ADJACENT HARDSCAPING
5. PLACE DRAINAGE FILL PRIOR TO INSTALLATION
NOTES:
OR HARDSCAPING.
FLOW
BRICK
12" OF DRAINAGE FILL
BELOW VALVE
BRICK
(LENGTH AS REQUIRED)
PVC SCH 40 STREET ELL
PVC SCH 40 TEE OR ELL
PVC MAINLINE PIPE
PVC SCH 40 STREET ELL
PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
BRICK
PVC SCH 40 ELL
PVC SCH 80 NIPPLE
6 INCH MINIMUM DEPTH OF
DRAINAGE FILL
BRICK
LATERAL LIN, ANGLE TO
12" MIN. DEPTH AS REQ'D.
SCH 80 PVC UNION
UPSTREAM OF VALVE
BALL VALVE
PIG TAIL EXPANSION LOOP
ELECTRICAL CONTROL VALVE
CONTROL & COMMON WIRES
(18" MIN.)
FINISHED GRADE
VALVE BOX WITH COVER
TOP OF QUICK-COUPLER AS CLOSE
TO VALVE BOX LID AS POSSIBLE
VALVE BOX WITH LOCKING COVER
10 INCH ROUND
QUICK-COUPLER VALVE
FINISHED GRADE
PVC SCH 40 ELL
PVC SCH 40 TEE OR ELL
PVC SCH 40 ELL
(LENGTH AS REQUIRED)
PVC LATERAL PIPE
PVC SCH 80 NIPPLE
PVC SCH 40 STREET ELL
(LENGTH AS REQUIRED)
PVC SCH 80 NIPPLE
FINISHED GRADE
POP-UP SPRINKLER
RUBBER COVER
1" SCH 80 NIPPLE
PVC LATERAL LINE
(LENGTH AS REQUIRED)
GEARED ROTOR
PVC TEE
1" STREET ELL
SEE LEGEND
1" STREET ELLS
1 FINISH GRADE
18" MINIMUM
WIRE IN
PVC SLEEVE (TYP.)
SUBMAIN
BACKFILL COMPACTED
TO 90%
TRENCH IN PLANTER
MAIN LINE
WIRE
WIRE
TRENCH UNDER PAVEMENT
MAIN LINE IN
PVC SLEEVE (TYP.)
PLANTER
FINISH GRADE
1. TIE A LOOSE 20" DIAMETER LOOP IN WIRE AT CHANGES IN DIRECTION OF 30°
OR GREATER. UNTIE AFTER CONNECTIONS ARE MADE.
2. ALL PIPE WIRE OR SLEEVES UNDER PAVEMENT TO BE INSTALLED
PRIOR TO PAVEMENT AND AT A MIN. OF 24" DEEP.
3. BUNDLE AND TAPE WIRE AT 10' INTERVALS.
4. WIRE UNDER PAVEMENT TO BE IN CONDUIT
PAVEMENT
FINISH SURFACE
(LATERAL)
Piston Connected To Flip Top
26"x24"x8" Concrete Base
Sch 40 Electrical Sweep Ell For 120 VAC Power
Louvered Vent
Finish Grade
12"
2"
Optional Dome Antenna Radio and RR Radio Remote option) (RR Radio Remote option)
38"
5/8"x8' Copper Grounding Rod
PVC Sleeve For Ground Rod
#6 AWG Grounding Wire Connected To Ground Lug
120 VAC Junction Box (included with enclosure)
Mounting Bolts (bolts & template included with enclosure)
Sch 40 Electrical Sweep Ell For Low Voltage Control Wires
14"
Flip Top In Open Position
STAINLESS STEEL ENCLOSURE
(with Dome Antenna)
Transient Protection Board
GFI Outlet & Switch
Controller Panel Mounted Flush On Face Of Enclosure at a 25° Angle For Easy Access And Viewing
AISLE
CL
CL
Sacramento Office 180 Promenade Circle, Suite 300 Sacramento, California 95834
(916) 929-3323 Fax (916) 929-1772
A Wholly Owned Subsidiary of Jacobs
I-12
FLOW SENSORS / MASTER VALVE ASSEMBLY- PLAN
Minimum Upstream Distance
10 x Flow Meter Size
All Models of Controllers
12" Of DRAINGAGE FILL In Valve Boxes
Valve Box (
FLOW METER INSTALLATION
Master Valve
White
Blue
Flow Meter
Minimum Downstream Distance 5 x Flow Meter Size
Waterproof Electrical Connectors (do not use pre-filled type connectors)
Upstream Length
10" 12.5" 15" 20" 30" 80"
Pipe Sizing Chart
F.M.
Size
1" 1.25" 1.5 2" 3" 8"
Black Wire Harness
Black
Red
Downstream Length
5" 6.25" 7.5" 10" 15" 40"
FLOW METER / MASTER VALVE -SECTION
PUMP PAD & PUMPING SYSTEM DIAGRAMF7
+ 66.64+ 66.64
+ 66.64 + 66.64
+ TOP P PUMP PLATE =67.28
Pipe Saddle or Welded On Fitting (not included with Flow Meter) 2" Threaded Hex Adapter
(included with Flow Meter)
Flow Meter
Flow Meter Wires To Cluster unit Controller g
FLOW METER (8" SIZE)
F1
C1 C5
6'-8"
3'-4"
10X PIPE DIAMETER (TYPICAL)5X PIPE DIAMETER
3'-4" for 8" Size Master Valve use 12" Brick to stabilize Valve Boxes
2'-0"
2'-0"
| 14.0_SNC DD IrrigController_a |
| 14.0_SNC DD IrrigController_a |
| I-4 |
| 14.0_SNC DD IrrigController_b |
| 14.0_SNC DD IrrigController_b |
| I-5 |
| 14.0_SNC DD IrrigController_c |
| 14.0_SNC DD IrrigController_c |
| I-6 |
| 14.0_SNC DD IrrigController_d |
| 14.0_SNC DD IrrigController_d |
| I-7 |
| 14.0_SNC DD IrrigController_e |
| 14.0_SNC DD IrrigController_e |
| I-8 |
| 14.0_SNC DD IrrigController_f |
| 14.0_SNC DD IrrigController_f |
| I-9 |
| 14.0_SNC DD IrrigController_g |
| 14.0_SNC DD IrrigController_g |
| I-10 |
| 14.0_SNC DD IrrigLeg |
| 14.0_SNC DD IrrigLeg |
| I-1 |
| 1-2-Overall |
| 1-3-Mainline |
| I-11 |
| I-12 |
File details come from the government source that posted it. Updated .