This document is a large-scale architectural plan and partial building sections drawing (Sheet 101.AE301) for the VA Illiana Healthcare System's EHRM Infrastructure Upgrades project in Danville, IL. The drawing provides detailed floor plans and sections for specific rooms in Building 101, including IT rooms, telecom rooms, social worker spaces, and corridors. Key renovation details include installing new 45-minute-rated doors, fire-retardant plywood backboards, static-dissipative tile flooring, extending existing walls to building structure, and modifying electrical and data infrastructure. The plans show precise room configurations, wall treatments, and specific renovation requirements for rooms like TR 104E, TR 132E, and the IT room, with annotations about existing structural elements, flooring preparation, and wall modifications. The drawing is part of the bid documents for a fully sprinklered renovation project, stamped and signed by a Nebraska state architect on 05/28/2024.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
101.E
101.4
IT
106E
CORRIDOR
C4E
SOCIAL
WORKER
105E
A7
A25
A71
C R
101.D
101.4
101.AE301
F3
101.AE301
F1
AUDIOLOGIST
103E
CORRIDOR
C1E
CORRIDOR
C4E
TR
104E
A7
A7
A10
A1
A9
A9
A9
A21
A7
A4
E X
IS
T
IN
G
7/ 8"
F .V
IN-03.01
A25
10' - 7" F.V.
A144
A97
CR
101.E
101.12
101.11
101.AE301
F5
101.AE301
F7
STORAGE
133E1
TR
132E
CLOSET
C7E1
A9
A9
A5
A21
A25
A6
A6
A10
A8
A1
A1
A4
A61
A64
IN-04.01
IN-03.01
133E1
132E C7E1FAC
A99
A
A25
A6
A7
11' - 6"
5' - 6 1/8"
EXISTING
6' - 0" F.V.
A9
A144
A97
LARGE-SCALE PLANS & DETAILS GENERAL NOTES:
1. REFER TO DEMOLITION AND RENOVATION PLANS FOR
REQUIREMENTS RELATED TO INSTALLATION OF NEW
INTERIOR WALLS, CEILING AND ROOF MODIFICATIONS.
2. REFER TO COLOR SCHEDULE AND ROOM FINISH
SCHEDULES FOR INTERIOR AND EXTERIOR FINISH
COLORS.
A. TYPICAL FINISHES:
a. BASE-WALLS - 4"-H RESILIENT BASE W/
COVE (UNLESS NOTED OTHERWISE)
b. WALLS (GWB) - PAINT TO 6" ABOVE
FINISH CLG
c. WALLS (GWB/PLASTER) (TR ROOMS) -
PAINT FULL-HT TO B.O. STRUCTURE IN
ROOMS W/O CEILINGS
d. WALLS (CMU) - PAINT TO 6" ABOVE
FINISH CLG
e. WALLS (CMU) (TR ROOMS) - PAINT
FULL-HT TO B.O. STRUCTURE IN
ROOMS W/O CELINGS
f. FLOORS (EXCEPT TR ROOMS / DATA
CENTER) - VCT OR LVT (PER VA
GUIDELINES - SEE ROOM FINISH
SCHEDULE)
g. FLOORS (TR ROOM & DATA CENTER) -
STATIC-DISSIPATIVE VCT
h. CEILINGS (GWB) - PAINT CLG. WHITE
i. CEILINGS (SUSPENDED ACOUSTICAL
TILE) - MATCH CEILING TILES/GRID
PREVIOUSLY USED IN ROOM (UNLESS
NOTED OTHERWISE)
j. OVERHEAD STRUCTURE (TR ROOMS /
DATA CENTER) - PAINT CLG. WHITE
1. REFER TO SHEET GI004 FOR TEMPORARY
ENCLOSURE, PROTECTION OF EXISTING UTILITIES
AND PROTECTION OF THE BUILDING INTERIOR
DURING DEMOLITION AND CONSTRUCTION.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
FIELD VERIFICATION OF EXISTING CONDITIONS AND
CHANGES MADE TO THE BUILDING AND SITE SINCE
THE PUBLISHED DATE OF THE CONSTRUCTION
DOCUMENTS.
3. BELOW-GRADE CONDITIONS SHOWN ARE BASED
UPON AS-BUILT DRAWINGS PROVIDED BY THE VA.
VARIATION OF EXISTING CONDITIONS WHICH DIFFER
FROM THOSE SHOWN ON THE DRAWINGS SHALL BE
REPORTED TO THE COR UPON DISCOVERY.
4. THE CONTRACTOR SHALL RETAIN THE SERVICES OF
AN UNDERGROUND UTILITY LOCATE SERVICE PRIOR
TO START OF WORK ON SITE THAT INCLUDES
EXCAVATION, DEMOLITION OF EXISTING PAVEMENT
OR OTHER WORK THAT MAY DISTURB BELOW-GRADE
UTILITIES AND IMPROVEMENTS.
5. CONTRACTOR SHALL PROTECT ALL SITE
INFRASTRUCTURE UNLESS DIRECTED OTHERWISE BY
COR.
30 MIN. SMOKE BARRIER
1 HR SMOKE BARRIER
1 HR FIRE RATED
2 HR FIRE RATED
FIRE RATED WALL LEGEND
1. REFER TO AG001 FOR ARCHITECTURAL DEMOLITION AND
RENOVATION GENERAL NOTES.
2. EXISTING STRUCTURAL GRIDS, COLUMNS, BEAMS AND
RELATED ELEMENTS ARE TYPICALLY NOT SHOWN IN THE
ARCHITECTURAL DRAWINGS. GRIDS AND COLUMNS
WHICH MAY BE SHOWN ARE FOR COORDINATION AND
ORIENTATION PURPOSES ONLY AND NOT FOR ACTUAL
LOCATIONS OR SIZE OF COMPONENTS. THE
CONTRACTOR IS TO FIELD VERIFY LOCATIONS OF
COLUMNS AND STRUCTURAL MEMBERS / ELEMENTS. THE
CONTRACTOR SHALL HAVE ACCESS TO DRAWINGS HELD
BY THE VA FOR ESTABLISHMENT OF EXISTING
STRUCTURAL COMPONENTS IF NEEDED.
3. THE AREAS OF WORK SHOWN ARE ASSOCIATED WITH AN
OPERATING FACILITY THAT HAS CERTAIN AREAS THAT
MUST REMAIN IN SERVICE 24-HOURS A DAY, 7-DAYS A
WEEK.
4. SCHEDULE WORK TO MINIMIZE DISRUPTION OF
SERVICES. COORDINATE WORK SCHEDULE WITH THE
CONTRACTING OFFICER'S REPRESENTATIVE (COR).
5. COORDINATE WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK
TO CONFIRM ACCURACY IN THE DRAWINGS. REPORT ANY
DISCREPANCIES TO THE VA COR.
6. DO NOT SCALE THE DRAWINGS. FIELD VERIFY ALL
DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
7. PROVIDE SMOOTH, LEVEL TRANSITIONS FROM NEW
FINISH TO EXISTING FINISH TO REMAIN.
8. FINAL FINISH SELECTION TO BE MADE BY THE VA.
PROVIDE ALL MATERIAL TO VA FOR REVIEW AND
APPROVAL THOUGH COLOR BOARD SUBMITTAL FOR
BOTH MATERIAL, TYPE AND COLOR.
9. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL
NEW FINISHES TO COMPLETE THE WORK AS NECESSARY.
10. REMOVE AND REPLACE ELECTRICAL / DATA PLATES,
BOXES, LIGHTS AND ACCESSORIES AS NECESSARY.
ADJUST ELECTRICAL / DATA COMPONENTS AS
NECESSARY.
11. PROTECT ADJACENT SURFACES - FOR EXAMPLE, BUT
NOT LIMITED TO - SILLS, DOOR JAMBS AND HEAD
FINISHES AT WINDOWS AND DOORS TO NAME A FEW.
12. THE GENERAL CONTRACTOR SHALL PROVIDE DUST
PARTITIONS AS NECESSARY TO CLOSE OFF AREA OF
WORK FROM ACTIVE AREAS OF THE BUILDING.
13. ALL WALLS ARE DIMENSIONED TO FINISH FACE, UNLESS
NOTED OTHERWISE.
14. REFER TO MECHANICAL DRAWINGS FOR NEW
MECHANICAL UNITS AND WORK IN ROOMS.
15. REFER TO ELECTRICAL DRAWINGS FOR LIGHTING
LOCATIONS AND WORK IN ROOMS.
16. REFER TO TECHNOLOGY / TELECOM DRAWINGS FOR
TELECOM AND SERVER RACKS, CABLE TRAYS, CABLE
JACK LOCATIONS AND ITEMS RELATED TO TELECOM
WORK.
17. REFER TO HAZARDOUS MATERIALS NOTES ON SHEET
GI004 AND TO ENVIRONMENTAL DRAWINGS FOR
ABATEMENT PROCEDURES OF HAZARDOUS MATERIALS.
18. EXISTING AND NEW CABLE TRAYS NOT SHOWN FOR
CLARITY OF ARCHITECTURAL SCOPE OF WORK. REFER
TO TECHNOLOGY / TELECOM DRAWINGS FOR
INFORMATION RELATED TO THESE ITEMS.
19. REFERENCE TECHNOLOGY / TELECOM DRAWINGS FOR
AREAS WHERE NEW DATA JACK WALL OUTLETS WILL BE
PROVIDED IN ROOMS OUTSIDE OF THE TELECOM ROOMS.
PATCH AND PAINT AROUND DATA JACK WALL OUTLET AS
NEEDED. COORDINATE PAINT COLOR WITH EXISTING
WALL COLOR AND VA COR.
20. FIRE- AND SMOKE-SEAL ALL THROUGH-WALL
PENETRATIONS TO COMPLY WITH FIRE-SMOKE RATING
APPLICABLE TO WALL. PROVIDE A MINIMUM OF 1-HOUR
FIRE-SMOKE RATING WHERE WALL RATING IS NOT
SHOWN.
ARCHITECTURAL FLOOR PLAN GENERAL NOTES:
HSK
133E
CORRIDOR
C7E
FEMALE
LOCKERS
136E1
SOCIAL
WORKER
133D
RESTROOM
136E2
101.4
JOIST BRG - OUTER BAYS - B101
109'-4"
JOIST BRG - CTR BAYS - B101
111'-4"
101.AE301
F3
NEW PLYWD BACKBOARD
REMOVE EXIST FINISH FLOORING; PREP FOR &
REPLACE W/ NEW STATIC-DISSIPATIVE VCT (TYP)
EXIST PRECAST DOUBLE-
TEE CONC STRUCT (TYP)
EXIST ROOFING (TYP)
EXIST DR/FRAME TO REMOVE;
NEW 45M-RATED DR/FRAME (TYP)
EXIST WALL - SEAL JOINTS - PENETRATIONS FOR
ENCLOSURE OF ROOM TO B.O. STRUCTURE (TYP)
TR
104E
AUDIOLOGIST
103E
CORRIDOR
C4E
8'
1'
101.D
FIRST FLOOR - B101
100'-0"
JOIST BRG - OUTER BAYS - B101
109'-4"
JOIST BRG - CTR BAYS - B101
111'-4"
101.AE301
F1
NEW PLYWD BACKBOARD (TYP)
REMOVE EXIST FINISH FLOORING;
PREP FOR & REPLACE W/ NEW
STATIC-DISSIPATIVE VCT (TYP)
EXIST PRECAST DOUBLE-
TEE CONC STRUCT (TYP)
EXIST BRICK VENEER /
CMU EXT WALL (TYP)
EXIST DR/FRAME TO REMOVE;
NEW 45M-RATED DR/FRAME (TYP)
EXIST WALL - SEAL JOINTS - PENETRATIONS
FOR ENCLOSURE OF ROOM TO B.O.
STRUCTURE (TYP)
TR
104E
CORRIDOR
C1E
8'
1'
101.E
FIRST FLOOR - B101
100'-0"
JOIST BRG - OUTER BAYS - B101
109'-4"
JOIST BRG - CTR BAYS - B101
111'-4"
101.AE301
F7
PLYWD BACKBOARD (TYP)
REMOVE EXIST FINISH FLOORING; PREP
FOR & REPLACE W/ NEW STATIC-
DISSIPATIVE VCT (TYP)
EXIST PRECAST DOUBLE-TEE CONC STRUCT
(TYP)
EXIST BRICK VENEER / CMU EXT WALL
(TYP)
EXIST DR/FRAME TO REMOVE; NEW 45M-
RATED DR/FRAME (TYP)
EXIST WALL - SEAL JOINTS -
PENETRATIONS FOR ENCLOSURE OF
ROOM TO B.O. STRUCTURE (TYP)
STORAGE
133E1
TR
132E
NEW
DOOR/FRAME
(BEYOND)
EXIST CEILING - MODIFY FOR
RECONFIGURED ROOM - SEE
REFLECTED CEILING PLAN
101.11
FIRST FLOOR - B101
100'-0"
JOIST BRG - OUTER BAYS - B101
109'-4"
JOIST BRG - CTR BAYS - B101
111'-4"
101.AE301
F5
EXISTING PLYWD BACKBOARD
REMOVE EXIST FINISH FLOORING; PREP FOR &
REPLACE W/ NEW STATIC-DISSIPATIVE VCT
(TYP)
EXIST PRECAST DOUBLE-
TEE CONC STRUCT (TYP)
EXIST ROOFING (TYP)
EXIST DR/FRAME TO REMOVE;
NEW 45M-RATED DR/FRAME (TYP)
EXIST WALL - SEAL JOINTS -
PENETRATIONS FOR ENCLOSURE OF
ROOM TO B.O. STRUCTURE (TYP)
TR
132E
CORRIDOR
C7E
NEW PLYWD BACKBOARD
7'
1'
A
R C H I T E C
T
S T
A T
E
O F N E B
R A
S K
A
05/28/2024
RICHARD
JOSEPH
ONKEN
A-5125
56 Louis Prima Dr., Suite B, Covington, LA 70433 504.684.4408
VCI
Project Management
Construction Management
Engineering
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
STAMP:
321 4 5 6 7 8 9 10
DOUG ELIA
U.S. DEPARTMENT OF VETERANS AFFAIRS - ILLIANA HEALTHCARE SYSTEM
Cell: (217) 510-5945 Email: douglas.elia@va.gov
UNITED STATES
DEPARTMENT OF
VETERANS AFFAIRS
05/28/2024
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved Project Director:
Phase:
FULLY SPRINKLERED
BID DOCUMENTSARCHITECT / ENGINEER OF RECORD:CONSULTANTS:
DATE:REVISIONS: ; Sean Fitzpatrick or John Vollman
B
IM
1-
1-
V A
D a n v il le
I L
E
H R
M In fr a s tr u ct u re
U p g ra d e s
R
1-
V A
1-
.r v t
:1
:1
P
M
101.AE301
LARGE SCALE PLANS & PARTIAL BUILDING
SECTIONS
AHT STW/TJF/AHT
550-21-700EHRM INFRASTRUCTURE UPGRADES
DANVILLE FHCS
Danville, IL
1/4" = 1'-0" E3
FIRST FLOOR - RM 106E IT ROOM -105E SOCIAL WORKER / TELECOM ROOM
1/4" = 1'-0"
E1
FIRST FLOOR - RM 104E TELECOM ROOM (2-RACKS)
1/4" = 1'-0" E5
FIRST FLOOR - RM 132E TR / 132E1 IT ROOM
PLAN
NORTH
TRUE
NORTH
PLAN
NORTH
TRUE
NORTH
0' 2' 4' 8' 16'
1/4" = 1'-0" F1
PART SECN TR 104E CORR C4E-RM 103
1/4" = 1'-0"
F3
PART SECN TR 104E-CORR
1/4" = 1'-0" F5
PART SECN TR 132E
1/4" = 1'-0"
F7
B101 PART SECN TR ROOM 132E EXIST TIP-CLOSET
KEYNOTE LEGEND - FLOOR PLAN RENOVATION
KEY VALUE KEYNOTE TEXT
A1 NEW 45-MINUTE-RATED WOOD DOOR W/ HM FRAME;
SEE DOOR SCHEDULE.
A4 CEILING OPEN TO STRUCTURE - TYPICAL ALL TR
ROOMS FOR ACCESS (UNLESS NOTED OTHERWISE).
A5 EXISTING PLYWOOD BACKBOARD TO REMAIN; PAINT
PER ROOM FINISH SCHEDULE GENERAL NOTE 2 IF
FIRE-RETARDANT STAMPS ARE PRESENT (DO NOT
COVER FIRE RATING STAMP); IF FIRE-RETARDANT
STAMPS ARE NOT PRESENT, REMOVE EXISTING ITEMS
FROM WALL, REMOVE EXISTING PLYWOOD & REPLACE
W/ NEW FIRE-RETARDANT PLYWOOD, FINISH PER ROOM
FINISH SCHEDULE GENERAL NOTE 2.
A6 EXISTING 6" CMU WALL; EXTEND TO BOTTOM OF
EXISTING STRUCTURE FOR WALL CLOSURE.
A7 EXTEND EXISTING WALL UP TO B.O. STRUCTURE.
A8 NEW GWB/METAL STUD WALL; EXTEND FULL-HEIGHT
FROM FLOOR TO B.O. STRUCTURE.
A9 NEW 3/4" FIRE-RETARDANT PLYWOOD BACKBOARD
FULL LENGTH OF WALL (UNLESS NOTED OR SHOWN
OTHERWISE) X 8'H MINIMUM; MOUNT PLYWOOD 12"
ABOVE FINISH FLOOR. PAINT PANELS PER ROOM FINISH
SCHEDULE GENERAL NOTE 2.
A10 ACCESS CONTROL DEVICE; SEE TECH DWGS.
A21 NEW STATIC-DISSIPATIVE TILE (SDT) FLOORING AS
SCHEDULED; SEE ROOM FINISH SCHEDULE.
A25 SEE TELECOM-SERIES DWGS FOR WORK THIS ROOM.
A61 EXISTING ACT CEILING TO REMAIN; REPAIR AS NEEDED.
A64 EXISTING FLOORING TO REMAIN; PATCH/REPAIR AS
MAY BE REQ'D TO RESTORE ROOM FINISHES TO
ORIGINAL CONDITION.
A71 EXISTING DOOR & FRAME TO REMAIN.
A97 EXISTING FLOOR; PREP FOR NEW (SDT)
STATIC-DISSIPATIVE TILE FLOORING; SEE ROOM FINISH
SCHEDULE.
A99 CLEAN AGENT FIRE EXTINGUISHER (PROVIDED BY VA)
A144 EXISTING FLOOR; PREP FOR NON-SDT FLOORING AS
SCHEDULED; SEE ROOM FINISH SCHEDULE.
1/4" = 1'-0"
File details come from the government source that posted it. Updated .