The document is an architectural drawing (58.AE401) depicting partial building sections for the VA Illiana Healthcare System's EHRM Infrastructure Upgrades project in Danville, IL. The detailed technical drawing shows renovation plans for Building 58, specifically focusing on treatment rooms (TR) across multiple floors, including floor levels from basement to attic. Key renovation elements include removing existing suspended acoustical ceilings, replacing finish flooring with static-dissipative vinyl composition tile (VCT), installing new fire-rated doors and frames, sealing wall joints and penetrations, and modifying existing walls and ceilings. The drawing includes specific room annotations for spaces like storage rooms, waiting areas, comfort rooms, and IT rooms, with detailed keynotes explaining precise construction and renovation specifications.

View the file

Other files

File Type Posted
36C77625B0011 0006.pdf PDF
Abstract of Bids OF 1419 - CONSTRUCTION - Signed 8.11.25.pdf PDF
Attachment 21 - Technical Questions - Danville IL 8-5-2025.pdf PDF
36C77625B0011 0005.docx DOCX document
Attachment 21 - Technical Questions - Danville IL 7-30-2025.pdf PDF
36C77625B0011 0004.pdf PDF
Attachment 23 - A-903.pdf PDF
Attachment 3 Construction Wage Rates Vermilion 7.25.25.pdf PDF
Attachment 21 - Technical Questions - Danville IL 7-28-2025.pdf PDF
Solicitation 36C77625B0011 Amendment 0003 - Danville IL EHRM Construction.pdf PDF
Attachment 21 - Technical Questions - Danville IL 7-15-2025.docx DOCX document
Attachment 19 - Soil Report Danville IL - 7-15-25.pdf PDF
Attachment 18 - RFI Log_EHRM Upgrades Danville IL.xls XLS spreadsheet
Attachment 22 - Electrical Single Line.pdf PDF
Attachment 11 - 02 82 11_Appendix_Asbestos Containing Materials Report Crosswalk.pdf PDF
Attachment 20 - Stamped Civil Drawings.pdf PDF
Attachment 17 - FloorHeightTable.xlsx XLSX spreadsheet
Attachment 16 - FloorHeightTable.pdf PDF
Attachment 15 - 013324 - Electronic Submittals.pdf PDF
Attachment 14 -101.AE301.pdf PDF
Attachment 12 - 58.AE301.pdf PDF
Amendment - 0002 36C77625B0011.pdf PDF
Attachment 23 - Construction Wage Rates - Vermilion 7-11-25.pdf PDF
Amendment - 0001 36C77625B0011.pdf PDF
Attachment 10 Limitations on Subcontracting Construction.pdf PDF
Attachment 7 Drawings Danville IL EHRM IU Construction Volume 2 of 3.pdf PDF
Attachment 1 Specifications Danville IL EHRM IU Construction Volume 1 of 2.pdf PDF
Attachment 9 Brand Name Justification Danville IL EHRM IU Construction.pdf PDF
Attachment 8 Drawings Danville IL EHRM IU Construction Volume 3 of 3.pdf PDF
Attachment 6 Drawings Danville IL EHRM IU Construction Volume 1 of 3.pdf PDF
Attachment 5 Pre Construction Risk Assessment Danville IL EHRM IU.docx DOCX document
Attachment 4 Site Visit Instructions EHRM IU 550 21 700.docx DOCX document
Attachment 3 Construction Wage Rates Vermilion 4 18 25.pdf PDF
Attachment 2 Specifications Danville IL EHRM IU Construction Volume 2 of 2.pdf PDF
36C77625B0011_1.docx DOCX document
36C77625B0011.docx DOCX document
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIRD FLOOR - B58

125' - 0"

FOURTH FLOOR - B58

137' - 0"

58.G 58.F58.D

SECOND FLOOR - B58

113' - 0"

FIRST FLOOR - B58

100' - 0"

58.AE401

F3

REMOVE EXIST FINISH FLOORING;

PREP FOR & REPLACE W/ NEW

STATIC-DISSIPATIVE VCT (TYP)

EXIST EXTERIOR MASONRY WALL

EXIST CONC STRUCT (TYP)

EXIST CONC BEAM (TYP)

NEW 45M-RATED DR/FRAME

EXIST CORRIDOR WALL - SEAL JOINTS -

PENETRATIONS FOR ENCLOSURE OF

ROOM TO B.O. STRUCTURE

(TYP)

NEW SUSP ACOUSTICAL CLG -

SEE REFL CLG PLAN

REMOVE EXIST SUSP ACOUSTICAL

CLG; REPLACE W/ NEW SUSP

ACOUSTICAL CLG - SEE REFL CLG PLAN

REMOVE EXIST SUSP ACOUSTICAL CLG

EXIST - SALVAGE GWB / MLT STUD WDW

POCKET / BULKHEAD - SEE REFL CLG PLAN

1ST FLR ARCH FFE = 100'-0" -

CIVIL FFE = 644.06' (1959 REV.)

EXIST CORRIDOR WALL - SEAL JOINTS -

PENETRATIONS FOR ENCLOSURE OF

ROOM TO B.O. STRUCTURE (TYP)

TR

STORAGE

208A

WAITING

308A

A9

A67

EXIST - SALVAGE GWB / MTL STUD

SOFFIT - SEE REFL CLG PLAN

A1

A1

A9

NEW GWB / MLT STUD WDW POCKET /

BULKHEAD - SEE F3/A-501 REFL CLG PLAN

A-501

A4 Sim A-501

F3 Sim

A-501

F3 Sim

THIRD FLOOR - B58

125' - 0"

FOURTH FLOOR - B58

137' - 0"

58.24

SECOND FLOOR - B58

113' - 0"

FIRST FLOOR - B58

100' - 0"

58.AE401

F1

58.AE401

F5

EXIST WALL - SEAL JOINTS &

PENETRATIONS FOR ENCLOSURE OF

ROOM TO B.O. STRUCTURE (TYP)

REMOVE EXIST FINISH FLOORING; PREP

FOR & REPLACE W/ NEW STATIC-

DISSIPATIVE VCT (TYP)

EXIST CONC STRUCT (TYP)

EXIST CONC BEAM (TYP)

EXIST WALL - SEAL JOINTS -

PENETRATIONS FOR ENCLOSURE OF

ROOM TO B.O. STRUCTURE (TYP)

NEW SUSP ACOUSTICAL CLG

- SEE REFL CLG PLAN

NEW GWB / MTL. STUD WALL

TO B.O. STRUCT

NEW GWB / MLT STUD WDW POCKET

/ BULKHEAD - SEE REFL CLG PLAN

NEW GWB / MTL. STUD WALL

TO B.O. STRUCT

1ST FLR ARCH FFE = 100'-0" -

CIVIL FFE = 644.06' (1959 REV.)

58.20.8

STORAGE

208A

TR

TR

WAITING

308A

HAC

TR

A9

A9

A67

A67 A67

A9

A9

A67 A67

A137

A137

D4

D4

D4

58.22.458.22 58.23

REMOVE EXIST SUSP ACOUSTICAL

CLG; REPLACE W/ NEW SUSP

ACOUSTICAL CLG - SEE REFL CLG PLAN

THIRD FLOOR - B58

125' - 0"

FOURTH FLOOR - B58

137' - 0"

FIFTH FLOOR - B58

149' - 6

ATTIC - B58

162' - 0"

58.G 58.F58.D

SECOND FLOOR - B58

113' - 0"

58.AE401

F3

REMOVE EXIST FINISH FLOORING;

PREP FOR & REPLACE W/ NEW

STATIC-DISSIPATIVE VCT (TYP)

EXIST EXTERIOR MASONRY WALL

EXIST CONC STRUCT (TYP)

EXIST CONC BEAM (TYP)

REMOVE EXIST DR/FRAME - REPL W/

NEW 45M-RATED DR/FRAME (TYP)

EXIST CORRIDOR WALL - SEAL JOINTS -

PENETRATIONS FOR ENCLOSURE OF

ROOM TO B.O. STRUCTURE (TYP)

REMOVE EXIST SUSP ACOUSTICAL CLG (TYP)

TR

TR

58.AE401

B1

COMFORT

ROOM

X-RAY

MODIFY EXIST SUSPENDED

ACOUSTICAL TILE CEILING FOR NEW

WALL - SEE REFLECTED CEILNG PLAN

A67

A9 A1

A67

A9 A1

D4

D4

A137

A137

FOURTH FLOOR - B58

137' - 0"

FIFTH FLOOR - B58

149' - 6

58.F 58.E

58.AE401

C1

REMOVE EXIST FINISH FLOORING;

PREP FOR & REPLACE W/ NEW STATIC-

DISSIPATIVE VCT (TYP)

EXIST WALL - SEAL JOINTS /

PENETRATIONS FOR ENCLOSURE

OF ROOM TO B.O. STRUCTURE (TYP)

EXIST CONC STRUCT (TYP)

EXIST CONC BEAM (TYP)

TR

D102 A9

A1

A

A118

A9

REMOVE PORTION OF EXIST SUSP.

ACOUSTICAL TILE CLG. INSIDE TR

ROOM - MODIFY REMAINING

CEILING IN WAITING ROOM TO

MEET NEW WALL

D102

A122

FOURTH FLOOR - B58

137' - 0"

FIFTH FLOOR - B58

149' - 6

58.AE401

C3

EXIST WALL - SEAL JOINTS /

PENETRATIONS FOR ENCLOSURE

OF ROOM TO B.O. STRUCTURE

(TYP)

EXIST CONC STRUCT (TYP)

EXIST CONC BEAM (TYP)

58.18

TR

RESTROOM

437A

A9

A9

D102 D102

A1

D1

A118

A122

D4

THIRD FLOOR - B58

125' - 0"

FOURTH FLOOR - B58

137' - 0"

FIFTH FLOOR - B58

149' - 6

ATTIC - B58

162' - 0"

SECOND FLOOR - B58

113' - 0"

FIRST FLOOR - B58

100' - 0"

BASEMENT - B58

87' - 0"

1ST FLR ARCH FFE = 100'-0" -

CIVIL FFE = 632.06' (1959 REV)

58.17

IT

IT

IT

IT

SOILED

LINEN

1. SEE SHEET AG001 FOR GENERAL NOTES.

2. EXISTING STRUCTURAL GRIDS, COLUMNS, BEAMS AND RELATED

ELEMENTS ARE TYPICALLY NOT SHOWN IN THE ARCHITECTURAL

DRAWINGS. GRIDS AND COLUMNS WHICH MAY BE SHOWN ARE

FOR COORDINATION AND ORIENTATION PURPOSES ONLY AND

NOT FOR ACTUAL LOCATION OR SIZE OF COMPONENTS. THE

CONTRACTOR IS TO FIELD VERIFY LOCATIONS OF COLUMNS

AND STRUCTURAL MEMBERS AND OBTAIN DRAWINGS PROVIDED

BY THE VA FOR ESTABLISHMENT OF EXISTING STRUCTURAL

CONDITIONS IF NEEDED.

3. REFER TO SHEETS PREPARED BY OTHER DISCIPLINES FOR

STRUCTURAL, MECHANICAL, ELECTRICAL AND

TELECOMMUNICATIONS WORK.

ARCHITECTURAL RENOVATION GENERAL NOTES:

FIFTH FLOOR - B58

149' - 6

ATTIC - B58

162' - 0"

58.2758.2458.AE401

F5

58.20.8 58.AE401

B4

COMFORT

ROOM

TR

CONSULT.

ROOM

507A

WAITING

ROOM

507B

MODIFY EXIST

CEILING &

SOFFITS FOR

NEW WALL

MODIFY EXIST

CEILING FOR

NEW WALL

EXIST WALL

EXIST CONC PAN JOIST

GWB CLOSURE - EXIST WALL / B.O. CONC PAN JOIST -

ATTACH TO EXIST LT.GA. MTL. FRAMING

AA

A106

A9 A9

A102

A67

58.22.458.22 58.23

FIFTH FLOOR - B58

149' - 6

ATTIC - B58

162' - 0"

58.G 58.F58.D58.AE401

B1

TR

CORRIDOR

C5-3

CLOSE EXIST WALL UP TO

B.O. STRUCTURE

VINYL BASE AS

SCHEDULED

REFINISH EXIST WALL - SEE

ROOM FINISH SCHEDULE

EXIST EXTERIOR WALL

A67

A9

A1

A102 A118

EXIST CORRIDOR WALL

A

R C H I T E C

T

S T

A T

E

O F N E B

R A

S K

A

05/28/2024

RICHARD

JOSEPH

ONKEN

A-5125

56 Louis Prima Dr., Suite B, Covington, LA 70433 504.684.4408

VCI

Project Management

Construction Management

Engineering

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMP:

321 4 5 6 7 8 9 10

DOUG ELIA

U.S. DEPARTMENT OF VETERANS AFFAIRS - ILLIANA HEALTHCARE SYSTEM

Cell: (217) 510-5945 Email: douglas.elia@va.gov

UNITED STATES

DEPARTMENT OF

VETERANS AFFAIRS

05/28/2024

Project Number:

Building Number:

Drawing Number:

Project Title:

Location:

Issue Date: Checked: Drawn:

Drawing Title:

Approved Project Director:

Phase:

FULLY SPRINKLERED

BID DOCUMENTS

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

DATE:REVISIONS:

; Sean Fitzpatrick or John Vollman

B

IM

1-

1-

V A

D a n v il le

I L

E

H R

M In fr a s tr u ct u re

U p g ra d e s

R

1-

V A

1-

.r v t

:1

:5

P

M

58.AE401

PARTIAL BUILDING SECTIONS

AHT STW/AHT

550-21-700EHRM INFRASTRUCTURE UPGRADES

DANVILLE FHCS

Danville, IL

1/4" = 1'-0" F1

B58 PART SECN TR ROOMS 107-208A-308A DR-WDW

1/4" = 1'-0"

F3

B58 PART SECN TR ROOMS 107-208-208A-308-308A

1/4" = 1'-0" F5

B58 PART SECN TR ROOMS 208-308 DR-WDW

1/4" = 1'-0" C3

B58 PART SECN TR ROOM 438 DR-WALL

1/4" = 1'-0"

C1

B58 PART SECN TR ROOM 438-437A

1/4" = 1'-0" F8

B58 BLDG PART SECN EXIST TIP ROOMS

1/4" = 1'-0" B1

B58 PART SECN ROOMS 506-507-507A-507B

KEYNOTE LEGEND - FLOOR PLAN RENOVATION

KEY VALUE KEYNOTE TEXT

A1 NEW 45-MINUTE-RATED WOOD DOOR W/ HM FRAME;

SEE DOOR SCHEDULE.

A9 NEW 3/4" FIRE-RETARDANT PLYWOOD BACKBOARD

FULL LENGTH OF WALL (UNLESS NOTED OR SHOWN

OTHERWISE) X 8'H MINIMUM; MOUNT PLYWOOD 12"

ABOVE FINISH FLOOR. PAINT PANELS PER ROOM

FINISH SCHEDULE GENERAL NOTE 2.

A67 APPLY BLAST FILM WITH ADDITIONAL LAYER OF

VISION-OBSCRUING FILM; SEE WINDOW SECURITY

DETAIL B1/A-901.

A102 EXISTING CHASE; EXTEND CLOSURE TO B.O.

STRUCTURE W/ GWB/MTL STUDS; SEE SHEET A-802

FOR CLOSURE DETAILS.

A106 LINE OF EXISTING CONC PAN JOIST ABOVE CEILING;

CLOSE OFF GAP BETWEEN WALL AND PAN JOIST WITH

5/8” GWB; COVER MTL STUD 'BRIDGES' THAT HOLD

WALL IN PLACE FROM F.O. WALL TO BOTTOM OF

ADJACENT PAN JOIST OVER WAITING RM. 507B FOR

FULL CLOSURE OF WALL.

A118 CLOSE TOP OF CHASE TO B.O. STRUCT W/ GWB/MTL

STUDS OVER F.O. EXISITNG CHASE WALL; INSTALL 5/8"

TYPE 'X' GWB OVER EXISITNG LT GA MTL. FRAMING IF

PRESENT, OR INSTALL LT GA FRAMING INSIDE CHASE

W/ 5/8" TYPE 'X' GWB TO CLOSE BETWEEN T.O.

PLASTER AND B.O. STRUCTURE. SEE SHEET A-802 FOR

CLOSURE DETAILS.

A122 EXISITNG 'WET' WALL; WATERPROOF SECTION W/

PEEL-N-STICK BEHIND PLYWOOD UP FROM FLOOR;

EXTEND GWB @ EXISITNG WALL UP TO B.O.

STRUCTURE.

A137 INSTALL STATIC-DISSIPATIVE TILE (SDT) FLOORING AS

SCHEDULED.

1/4" = 1'-0" B4

B58 PART SECN TR RM 507

KEYNOTE LEGEND - FLOOR PLAN DEMOLITION

KEY VALUE KEYNOTE TEXT

D1 REMOVE EXISITNG DOOR/FRAME/HW; PREP FOR NEW

DOOR/FRAME OR INFILL TO MATCH EXISITNG WALL

CONST; SEE RENOVATION PLANS & DOOR SCHEDULE.

D4 REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING

ASSEMBLY IN ITS ENTIRETY; LEAVE CEILING OPEN TO

STRUCTURE IN ALL TR ROOMS (TYPICAL UNLESS

NOTED OTHERWISE).

D102 REMOVE COUNTERTOP/BRACKETS; RETURN TO VA.