Attachment 12 - 58.AE301.pdf
PDF 1 MB Posted
- Solicitation number
- 36C77625B0011
About this file
This document is a large-scale architectural floor plan for the EHRM Infrastructure Upgrades project at the VA Illiana Healthcare System in Danville, IL, specifically focusing on Building 58. The detailed architectural drawing provides comprehensive floor plans for multiple levels (first through fifth floors), showing proposed renovations for various rooms including telecom (TR) rooms, storage areas, waiting rooms, and corridors. Key renovation elements include installing new fire-rated walls, static-dissipative tile flooring, plywood backboards, access control devices, security film, and penetration sleeves, with specific attention to room-by-room modifications and infrastructure improvements across different floor levels.
The floor plans include extensive technical annotations and keynotes detailing construction specifications, such as wall types, door installations, ceiling treatments, and specific renovation requirements for each room. The document is part of the broader VA infrastructure upgrade project, stamped with architectural and engineering details, including the architect's professional license information and project metadata. The drawings are prepared by VCI Project Management and are dated 05/28/2024, indicating they are part of the bid documentation phase for the infrastructure upgrade project targeting various buildings within the VA Illiana Healthcare System campus.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
58.14
58.K
58.17
A25
IN-04.01
FE
CLOSET
100B
CR
58.2558.24
58.G
58.F
58.G'
58.D
58.AE401
F1
58.AE401
F3
TR
A9 A9
A6
A7
A10
A1
A9
A4
A21
A62
EXISTING
9' - 1" F.V.
E X
IS
T
IN
G
/2
F .V
IN-03.01 IN-04.01
A26
HAC
OFFICE
A9
58.22.458.22 58.23
EXIST. PLASTER-LATH
WALL OVER LT.GA.
FRAMING BTW ROOMS
107-108. CLOSE OFF
WALL TO B.O.
STRUCTURE W/
PLASTER-MTL LATH
OVER EXIST. FRAMING.
EXIST STRUCT. CLAY
TILE/PLASTER WALL -
CLOSE OFF WALL TO B.O.
STRUCTURE; INFILL BTW.
T.O. EXIST. WALL & B.O.
STRUCT. W/ STRUCT.
CLAY TILE W/ PLASTER
OVER STRUCT. CLAY TILE
A3
A97
A144 A144
A9
58.G
58.J'
58.J
58.I
58.H
58.G'
58.AE401
F8
58.1858.17
A25
IT
CR
58.G
58.F
58.D
58.AE401
F1
58.AE401
F5
58.AE401
F3
58.20.858.20
TR
STORAGE
208A
A9
A9 A8
A58
A9
A1
A10
A4
A59
A3
A21
A62
A61
E X
IS
T
IN
G
/8
F .V
IN-03.01 IN-04.01
A
10' - 8" F.V.
A99 FE
208 208A
A100
A100
A101
E X
IS
T
IN
G
1"
F .V
EXISTING
16' - 6 3/4" F.V.
A118
A118
A58
58.22.458.22 58.23
A1
A97
A144
A26 A26
58.J'
58.J
58.I
58.H
58.G'
58.AE401
F8
58.1858.17
IT
A25
CR
58.24
58.G
58.F
58.D
58.AE401
F1
58.AE401
F5
58.AE401
F3
58.20.8
TR
WAITING
308A
A9 A9
A9
A10
A21
A8
A4
A1
A62
E X
IS
T
IN
G
'-9
/2
F
.V
11" F.V. 10'-7" F.V.
11' - 1"
E X
IS
T
IN
G
/4
F .V
A
IN-03.01
IN-04.01
A26 A26
CORRIDOR
C3-5
F1
A98
A F1
A100
A102 7' - 1 3/8" F.V.
58.22.458.22 58.23
A97
A144
58.J'
58.J
58.I
58.H
58.G'
58.AE401
F8
58.1858.17
A25
IT
CR
58.E
58.AE401
C3
58.AE401
C1
58.18 58.1958.17
TR
PT
WAITING
ROOM
RESTROOM
437A
A1 A3
A10
A29
A29
A9
A9
A9
A8
A21
A22
A28
A28
A4
A7
A60
A61
'-7
F
.V
IN-03.01
CORRIDOR
C4-6
A
A102
EXISTING
12' - 5 3/4" F.V.
A119
A97
58.J'
58.J
58.I
58.H
58.G'
58.AE401
F8
58.1858.17
A25
IT
LARGE-SCALE PLANS & DETAILS GENERAL NOTES:
1. REFER TO DEMOLITION AND RENOVATION PLANS FOR
REQUIREMENTS RELATED TO INSTALLATION OF NEW
INTERIOR WALLS, CEILING AND ROOF MODIFICATIONS.
2. REFER TO COLOR SCHEDULE AND ROOM FINISH
SCHEDULES FOR INTERIOR AND EXTERIOR FINISH
COLORS.
A. TYPICAL FINISHES:
a. BASE-WALLS - 4"-H RESILIENT BASE W/
COVE (UNLESS NOTED OTHERWISE)
b. WALLS (GWB) - PAINT TO 6" ABOVE
FINISH CLG
c. WALLS (GWB/PLASTER) (TR ROOMS) -
PAINT FULL-HT TO B.O. STRUCTURE IN
ROOMS W/O CEILINGS
d. WALLS (CMU) - PAINT TO 6" ABOVE
FINISH CLG
e. WALLS (CMU) (TR ROOMS) - PAINT
FULL-HT TO B.O. STRUCTURE IN
ROOMS W/O CELINGS
f. FLOORS (EXCEPT TR ROOMS / DATA
CENTER) - VCT OR LVT (PER VA
GUIDELINES - SEE ROOM FINISH
SCHEDULE)
g. FLOORS (TR ROOM & DATA CENTER) -
STATIC-DISSIPATIVE VCT
h. CEILINGS (GWB) - PAINT CLG. WHITE
i. CEILINGS (SUSPENDED ACOUSTICAL
TILE) - MATCH CEILING TILES/GRID
PREVIOUSLY USED IN ROOM (UNLESS
NOTED OTHERWISE)
j. OVERHEAD STRUCTURE (TR ROOMS /
DATA CENTER) - PAINT CLG. WHITE
1. REFER TO SHEET GI004 FOR TEMPORARY
ENCLOSURE, PROTECTION OF EXISTING UTILITIES
AND PROTECTION OF THE BUILDING INTERIOR
DURING DEMOLITION AND CONSTRUCTION.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
FIELD VERIFICATION OF EXISTING CONDITIONS AND
CHANGES MADE TO THE BUILDING AND SITE SINCE
THE PUBLISHED DATE OF THE CONSTRUCTION
DOCUMENTS.
3. BELOW-GRADE CONDITIONS SHOWN ARE BASED
UPON AS-BUILT DRAWINGS PROVIDED BY THE VA.
VARIATION OF EXISTING CONDITIONS WHICH DIFFER
FROM THOSE SHOWN ON THE DRAWINGS SHALL BE
REPORTED TO THE COR UPON DISCOVERY.
4. THE CONTRACTOR SHALL RETAIN THE SERVICES OF
AN UNDERGROUND UTILITY LOCATE SERVICE PRIOR
TO START OF WORK ON SITE THAT INCLUDES
EXCAVATION, DEMOLITION OF EXISTING PAVEMENT
OR OTHER WORK THAT MAY DISTURB BELOW-GRADE
UTILITIES AND IMPROVEMENTS.
5. CONTRACTOR SHALL PROTECT ALL SITE
INFRASTRUCTURE UNLESS DIRECTED OTHERWISE BY
COR.
30 MIN. SMOKE BARRIER
1 HR SMOKE BARRIER
1 HR FIRE RATED
2 HR FIRE RATED
FIRE RATED WALL LEGEND
1. REFER TO AG001 FOR ARCHITECTURAL DEMOLITION AND
RENOVATION GENERAL NOTES.
2. EXISTING STRUCTURAL GRIDS, COLUMNS, BEAMS AND
RELATED ELEMENTS ARE TYPICALLY NOT SHOWN IN THE
ARCHITECTURAL DRAWINGS. GRIDS AND COLUMNS
WHICH MAY BE SHOWN ARE FOR COORDINATION AND
ORIENTATION PURPOSES ONLY AND NOT FOR ACTUAL
LOCATIONS OR SIZE OF COMPONENTS. THE
CONTRACTOR IS TO FIELD VERIFY LOCATIONS OF
COLUMNS AND STRUCTURAL MEMBERS / ELEMENTS. THE
CONTRACTOR SHALL HAVE ACCESS TO DRAWINGS HELD
BY THE VA FOR ESTABLISHMENT OF EXISTING
STRUCTURAL COMPONENTS IF NEEDED.
3. THE AREAS OF WORK SHOWN ARE ASSOCIATED WITH AN
OPERATING FACILITY THAT HAS CERTAIN AREAS THAT
MUST REMAIN IN SERVICE 24-HOURS A DAY, 7-DAYS A
WEEK.
4. SCHEDULE WORK TO MINIMIZE DISRUPTION OF
SERVICES. COORDINATE WORK SCHEDULE WITH THE
CONTRACTING OFFICER'S REPRESENTATIVE (COR).
5. COORDINATE WORK WITH ALL OTHER TRADES. VERIFY
ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK
TO CONFIRM ACCURACY IN THE DRAWINGS. REPORT ANY
DISCREPANCIES TO THE VA COR.
6. DO NOT SCALE THE DRAWINGS. FIELD VERIFY ALL
DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
7. PROVIDE SMOOTH, LEVEL TRANSITIONS FROM NEW
FINISH TO EXISTING FINISH TO REMAIN.
8. FINAL FINISH SELECTION TO BE MADE BY THE VA.
PROVIDE ALL MATERIAL TO VA FOR REVIEW AND
APPROVAL THOUGH COLOR BOARD SUBMITTAL FOR
BOTH MATERIAL, TYPE AND COLOR.
9. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL
NEW FINISHES TO COMPLETE THE WORK AS NECESSARY.
10. REMOVE AND REPLACE ELECTRICAL / DATA PLATES,
BOXES, LIGHTS AND ACCESSORIES AS NECESSARY.
ADJUST ELECTRICAL / DATA COMPONENTS AS
NECESSARY.
11. PROTECT ADJACENT SURFACES - FOR EXAMPLE, BUT
NOT LIMITED TO - SILLS, DOOR JAMBS AND HEAD
FINISHES AT WINDOWS AND DOORS TO NAME A FEW.
12. THE GENERAL CONTRACTOR SHALL PROVIDE DUST
PARTITIONS AS NECESSARY TO CLOSE OFF AREA OF
WORK FROM ACTIVE AREAS OF THE BUILDING.
13. ALL WALLS ARE DIMENSIONED TO FINISH FACE, UNLESS
NOTED OTHERWISE.
14. REFER TO MECHANICAL DRAWINGS FOR NEW
MECHANICAL UNITS AND WORK IN ROOMS.
15. REFER TO ELECTRICAL DRAWINGS FOR LIGHTING
LOCATIONS AND WORK IN ROOMS.
16. REFER TO TECHNOLOGY / TELECOM DRAWINGS FOR
TELECOM AND SERVER RACKS, CABLE TRAYS, CABLE
JACK LOCATIONS AND ITEMS RELATED TO TELECOM
WORK.
17. REFER TO HAZARDOUS MATERIALS NOTES ON SHEET
GI004 AND TO ENVIRONMENTAL DRAWINGS FOR
ABATEMENT PROCEDURES OF HAZARDOUS MATERIALS.
18. EXISTING AND NEW CABLE TRAYS NOT SHOWN FOR
CLARITY OF ARCHITECTURAL SCOPE OF WORK. REFER
TO TECHNOLOGY / TELECOM DRAWINGS FOR
INFORMATION RELATED TO THESE ITEMS.
19. REFERENCE TECHNOLOGY / TELECOM DRAWINGS FOR
AREAS WHERE NEW DATA JACK WALL OUTLETS WILL BE
PROVIDED IN ROOMS OUTSIDE OF THE TELECOM ROOMS.
PATCH AND PAINT AROUND DATA JACK WALL OUTLET AS
NEEDED. COORDINATE PAINT COLOR WITH EXISTING
WALL COLOR AND VA COR.
20. FIRE- AND SMOKE-SEAL ALL THROUGH-WALL
PENETRATIONS TO COMPLY WITH FIRE-SMOKE RATING
APPLICABLE TO WALL. PROVIDE A MINIMUM OF 1-HOUR
FIRE-SMOKE RATING WHERE WALL RATING IS NOT
SHOWN.
ARCHITECTURAL FLOOR PLAN GENERAL NOTES:
GAS
STORAGE
100C
LOADING
DOCK
100A
CHUTE
STAIRS
S1
CORRIDOR
C2-2
CORRIDOR
C2-1
SOIL
CORR.
C2-4
SUPERV.
OFFICE
SOIL HOLD
CHUTE
STAIRS
S-1
CORRIDOR
C4-2
CORRIDOR
C4-1
58.2758.2658.2558.24
58.G
58.F
58.D
58.AE401
F5
CR
A27 A10
A26
A9 A9
A9
CONSULT.
ROOM
507ATR
WAITING
ROOM
507B
A21
A7
A1
507 507A
A3
A28
F.V.
9'-11"6'-6" F.V.11'-3"F.V.
58.AE401
B1
COMFORT
ROOM
506 E X
IS
T
IN
G
'-8
/2
F
.V .A
A
CAFEC1
A99
58.AE401
B4
10' - 7" F.V.
A106
IN-04.01IN-04.01IN-04.01IN-04.01
A87
58.22.458.22 58.23
A144 A144 A144
A97
A1
CORR.
C3-2
CHUTE
CORR.
C3-1
STAIRS
S1
SEE SHEET AG001 FOR ARCHITECTURAL
RENOVATION GENERAL NOTES
STAIRS
S1.
CORRIDOR
C5-2
CHUTE
ROOM
CORRIDOR
C5-1
A
R C H I T E C
T
S T
A T
E
O F N E B
R A
S K
A
05/28/2024
RICHARD
JOSEPH
ONKEN
A-5125
56 Louis Prima Dr., Suite B, Covington, LA 70433 504.684.4408
VCI
Project Management
Construction Management
Engineering
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
STAMP:
321 4 5 6 7 8 9 10
DOUG ELIA
U.S. DEPARTMENT OF VETERANS AFFAIRS - ILLIANA HEALTHCARE SYSTEM
Cell: (217) 510-5945 Email: douglas.elia@va.gov
UNITED STATES
DEPARTMENT OF
VETERANS AFFAIRS
05/28/2024
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved Project Director:
Phase:
FULLY SPRINKLERED
BID DOCUMENTSARCHITECT / ENGINEER OF RECORD:CONSULTANTS:
DATE:REVISIONS: ; Sean Fitzpatrick or John Vollman
B
IM
1-
1-
V A
D a n v il le
I L
E
H R
M In fr a s tr u ct u re
U p g ra d e s
R
1-
V A
1-
.r v t
:1
:3
P
M
58.AE301
LARGE SCALE PLANS
AHT STW/TJF
550-21-700EHRM INFRASTRUCTURE UPGRADES
DANVILLE FHCS
Danville, IL
1/4" = 1'-0" B1
B58 - FIRST FLOOR - RM 100B - TIP ROOM
1/4" = 1'-0"
B3
B58 - FIRST FLOOR - RMS 106-107-107A-108 - TR ROOM (2-RACKS)
1/4" = 1'-0" B5
B58 - SECOND FLOOR - RM 200-201 - STORAGE
1/4" = 1'-0" D1
B58 - SECOND FLOOR - RMS 208-208A - NEW TR ROOM (3-RACKS)
1/4" = 1'-0"
D3
B58 - THIRD FLOOR - RM 300-301 - STORAGE
1/4" = 1'-0" D5
B58 - THIRD FLOOR - RM 308 - NEW TR WAITING RM
1/4" = 1'-0" D7
B58 - FOURTH FLOOR - RM 400-401 - EXIST TIP ROOM
1/4" = 1'-0" F1
B58 - FOURTH FLOOR - RM 438 - NEW TR ROOM (3-RACKS)
1/4" = 1'-0"
F3
B58 - FIFTH FLOOR - RM 500-501
1/4" = 1'-0" F5
B58 - FIFTH FLOOR - RMS 506 -507-507A - NEW TR / RENOVATE COMFORT-
CONSULT-WAITING RMS
KEYNOTE LEGEND - FLOOR PLAN RENOVATION
KEY VALUE KEYNOTE TEXT
A1 NEW 45-MINUTE-RATED WOOD DOOR W/ HM FRAME;
SEE DOOR SCHEDULE.
A3 INFILL OPENING TO MATCH EXISTING WALL
CONSTRUCTION.
A4 CEILING OPEN TO STRUCTURE - TYPICAL ALL TR
ROOMS FOR ACCESS (UNLESS NOTED OTHERWISE).
A6 EXISTING 6" CMU WALL; EXTEND TO BOTTOM OF
EXISTING STRUCTURE FOR WALL CLOSURE.
A7 EXTEND EXISTING WALL UP TO B.O. STRUCTURE.
A8 NEW GWB/METAL STUD WALL; EXTEND FULL-HEIGHT
FROM FLOOR TO B.O. STRUCTURE.
A9 NEW 3/4" FIRE-RETARDANT PLYWOOD BACKBOARD
FULL LENGTH OF WALL (UNLESS NOTED OR SHOWN
OTHERWISE) X 8'H MINIMUM; MOUNT PLYWOOD 12"
ABOVE FINISH FLOOR. PAINT PANELS PER ROOM
FINISH SCHEDULE GENERAL NOTE 2.
A10 ACCESS CONTROL DEVICE; SEE TECH DWGS.
A21 NEW STATIC-DISSIPATIVE TILE (SDT) FLOORING AS
SCHEDULED; SEE ROOM FINISH SCHEDULE.
A22 NEW FLOOR DRAIN; SEE MEP DWGS.
A25 SEE TELECOM-SERIES DWGS FOR WORK THIS ROOM.
A26 APPLY NEW SECURITY/BLAST & VISION-OBSCURING
FILM AND INSTALL SECURITY SCREEN; SEE DETAIL
B1/A-901.
A27 NEW DOOR/FRAME – SEE DOOR SCHEDULE.
A28 NEW WALL - EXTEND TO TO B.O. STRUCTURE / DECK
ABOVE; SEE WALL TYPES.
A29 EXISTING CHASE TO REMAIN.
A58 EXISTING RADIATOR / CONVECTOR; SEE MECH.
A59 PROVIDE & INSTALL FIRE-RATED THROUGH-FLOOR
PENETRATION SLEEVES; SEE DETAILS SHEET A-802
A60 WATERPROOF EXISTING 'WET' WALL W/ BITUMINOUS
"PEEL AND STICK" SELF-ADHESIVE MEMBRANE.
A61 EXISTING ACT CEILING TO REMAIN; REPAIR AS
NEEDED.
A62 REPAIR/REPLACE/ADD CORRIDOR GUARDRAIL AT
WALL INFILL AS NEEDED; MATCH EXISTING.
A87 NEW FIRE EXTINGUISHER CABINET (FEC); REFER TO
SPECIFICATIONS FOR TYPE LABELED & DETAILS ON
SHT A-902.
A97 EXISTING FLOOR; PREP FOR NEW (SDT)
STATIC-DISSIPATIVE TILE FLOORING; SEE ROOM
FINISH SCHEDULE.
A98 INSTALL BITUMINOUS 'PEEL & STICK' WATER
PROOFING ON WALL & LAP TO FLOOR; COVER WITH
PLYWOOD & SDT.
A99 CLEAN AGENT FIRE EXTINGUISHER (PROVIDED BY VA)
A100 COLUMN WITH CHASE; EXTEND CLOSURE TO B.O.
DECK W/ GWB/MTL STUDS.
A101 PLUMBNG CHASE; SEE MECH & PLBG DWGS FOR
WORK RELATED TO PIPING RELOCATION IN TR
ROOMS.
A102 EXISTING CHASE; EXTEND CLOSURE TO B.O.
STRUCTURE W/ GWB/MTL STUDS; SEE SHEET A-802
FOR CLOSURE DETAILS.
A106 LINE OF EXISTING CONC PAN JOIST ABOVE CEILING;
CLOSE OFF GAP BETWEEN WALL AND PAN JOIST WITH
5/8” GWB; COVER MTL STUD 'BRIDGES' THAT HOLD
WALL IN PLACE FROM F.O. WALL TO BOTTOM OF
ADJACENT PAN JOIST OVER WAITING RM. 507B FOR
FULL CLOSURE OF WALL.
A118 CLOSE TOP OF CHASE TO B.O. STRUCT W/ GWB/MTL
STUDS OVER F.O. EXISITNG CHASE WALL; INSTALL 5/8"
TYPE 'X' GWB OVER EXISITNG LT GA MTL. FRAMING IF
PRESENT, OR INSTALL LT GA FRAMING INSIDE CHASE
W/ 5/8" TYPE 'X' GWB TO CLOSE BETWEEN T.O.
PLASTER AND B.O. STRUCTURE. SEE SHEET A-802 FOR
CLOSURE DETAILS.
A119 REINSTALL EXISITNG STAINLESS STEEL COLUMN
PROTECTION.
A144 EXISTING FLOOR; PREP FOR NON-SDT FLOORING AS
SCHEDULED; SEE ROOM FINISH SCHEDULE.
EXIST ROOM 107 ABOVE CEILING
EXIST ROOM 107 ABOVE CEILING @ CORR WALL
EXIST AREA ABOVE CEILING
0' 2' 4' 8' 16'
1/4" = 1'-0"
PLAN
NORTH
TRUE
NORTH