S06 - Amend 0009 - Att 11 - DWG EP101 - Rvd - SPS - Sioux Falls.pdf
PDF 857 KB Posted
- Solicitation number
- 36C77624R0115
About this file
This document is an electrical power floor plan drawing (EP101) for a new Sterile Processing Services (SPS) addition at the Sioux Falls VA Health Care System. The detailed architectural/engineering drawing depicts ground level and pipe basement electrical power distribution, including multiple equipment connections and receptacle locations across various rooms such as operating rooms, corridors, clean workrooms, and mechanical spaces. The drawing includes a comprehensive equipment schedule listing 16 specific electrical devices with their voltage, phase, amperage, and connection type, ranging from bar code readers and computers to steam sterilizers and washer/disinfector systems. The drawing is part of a VA construction project (#438-460) for a new approximately 8,500 square foot SPS addition, prepared by IMEG Corporation for the Department of Veterans Affairs, with a bid document issue date of 07/17/2024 and an addendum dated 05/20/2025.
View the file
Other files
Show 40 more
Latest 50 of 61 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E E EE
E
E
E
E
E
E E E E
E E
E
PP
P P
E
P P
P P
E
P P
P P
E
P P
PP
EE
PP
P P
P P
PP
E
PP
P P
PP
PP
E
E
PP
P P
E
P P
P P
E
E
E
P P
P P
PPPP
PP
P P
E
PP
P P
E
PP
P P
P P
P P
E
E
E
N P
Z.2
X
ML
W Y
Z
Z.1
L
M
N
O
SB
S2
23 24
1S
0S
A1
A2
30 Y
A
C
B
D
H
G
5.3
G.2
1.8
F
E
4 54.94.3
30.4
Z1
30.6
A1.8 uuuu
A1.9 wwww
A3.5
A3
1.7
TELECOM
H1
CLEAN HAC
H16
ANTE-ROOM CLEAN
H14
CLEAN WORKROOM, ASSEMBLY
H15
SPS CHIEF OFFICE
H11
ASSISTANT CHIEF OFFICE
H10
RME OFFICE
H9
STAFF LOUNGE
H8
HAC
H6
CORRIDOR
C52
DECONTAMINATION WORK AREA
H21
SOILED HAC
H22
DETERGENT
H23
CART HOLDING
H24
ANTEROOM, SOILED
TRANSITION/DROP-OFF
H25
TOILET
H7
LEAD TECH OFFICE
H5
OPEN OFFICE
H4
CONFERENCE/ TRAINING ROOM
H2
SCOPE PROCESSING
DECONTAMINATION ROOM
H26
LOGISTICS STORAGE ROOM
H18
CORRIDOR
C50
CORRIDOR
C51
SCOPE STAGING ROOM
H17A
MANUAL CART WASH
H20A
CART HOLDING
H20
AUTOMATIC CART WASH AREA
H20B
STERILE INSTRUMENT STORAGE
H17
MENS TOILET/LOCKER
H12
WOMENS TOILET/LOCKER
H13
STEAM STERILIZATION AREA
H19
WOMENS SHOWER
H13A
MENS SHOWER
H12A
OR #1
G25
CLEAN CORE
G26
OR #4
G27
CORRIDOR
C43
STORAGE
G28
STORAGE
G29
Room
D10
STAIR #4
D12
Room
D12A
Room
G02
TELE
G03
EMS
G04
ELEV EQUIP
G05
Room
G42A
CORRIDOR
C50
ELEVATOR LOBBY
G79-5
STAIR 9
G81-5
STEAM STERILIZER
H15A
ELECTRICAL
H3
DR WORK ROOM
D18
CORRIDOR
C12
LN4-47
+72"
LCE7-28
+54"
LCE7-28
+54"
LN4-57
+60"
LN4-21
COMPUTER/+60"
LN4-21
+60"
LN4-27
+72"
DS-S0442
30A
DS-S0442
30A
DS-S0442
30A
LN4-32
+42"
LN4-4
+72"
LN4-36
LN4-36
LN4-36
LN4-36
LN4-2
LN4-2
LN4-2
LN4-2
LN4-3
LN4-3
LN4-3
LN4-3
LN4-4 LN4-4
LN4-4
LN4-4
LN4-5
LN4-5
+42"
LN4-5
+42"
LN4-6
LN4-6
LN4-6
+42"
LN4-6
+42"
LN4-7
LN4-7
LN4-7
LN4-7
LN4-8
LN4-8LN4-8
LN4-9
LN4-9LN4-9
LN4-9
LN4-30/+42"
LN4-75LN4-30
+42"
LCE7-19,21,23
S5505
LN4-41,43,45
S5505
LN4-46,48,50
S5505
LCE7-5
S9610
LCE7-6
S9610
LCE7-24
LCE7-7/S0005
LCE7-8/S0003
LCE7-8/S0004
LN4-54
LN4-54
LN4-54
LN4-12
LCE7-26
LCE7-25
M3160 +80"
LN4-15
M3160 +80"
LN4-14
M3160 +80"
LN4-13
M3160 +80"
LN4-12
LN4-18
S2627
LCE7-27
S2627
LN4-22
A1195 +60"
LN4-22
LN4-20
S2627
LN4-22
LN4-22/A1195A/+60"
LN4-47
LN4-10
LN4-10
LN4-10
LN4-47
LN4-11
LN4-47
LN4-11
LN4-23
LN4-23
LN4-23
LN4-24
LN4-25
+46"
LN4-25
LN4-25LN4-25
S0007
LN4-28
+48"LN4-28
+48"
LN4-83
+42"
LN4-55
M1803/+60"
LN4-27
LN4-54
LN4-26
LN4-23
LN4-24
LN4-24
LCE7-3
S9610 LN4-83
+42"
LN4-83
LN4-29
M1803/+60"
LN4-29
M1803/+60"
LN4-57
LN4-57
LN4-57
LN4-56
LN4-56
LN4-56
LN4-56
LN4-12
LN4-58LN4-75
LN4-77
EWC-1
LN4-75
LN4-12
LN4-12
HN5-4
S0442
HN5-3
S0442
QH3-3
S0442
DS-S3185
30A
HN5-6
S3185
LCE7-1/S9610
LCE7-2/S9610
LCE7-4
S9610
QH3-8
S0940
QH3-7
S0940
HN5-2
S0940
HN5-1
S0940
DS-S0940
60A
DS-S0940
60A
DS-S0940
60A
DS-S0940
60A
LN4-40,42,44
S2635
LCE7-30,32,34
S2635/+42"
LCE7-29,31,33
S2635/+48"
QL3-3
S0046 +84"
LN4-35,37,39
S2635/+42"
LN4-1
R7250./+40"
LN4-16
+40"
LN4-17
+40"
LN4-19
+40"
LN4-31
+60"
LN4-32
+42"
LN4-58
LN4-32
W
LN4-12
LN4-49
LN4-51
LCE7-9
LCE7-11
LCE7-24/S0002
LN4-52
S0942
LN4-28
+42"
LN4-30
+42"
FB-1
LN4-10
LN4-22
+42"
LN4-12
LN4-24
LN4-23/+42"
LN4-30
LN4-72,74,76
S5505
LN4-33/W
LN4-59
S0941 LN4-60
S0941
LN4-62
S0941
LN4-69
S0941
LCE7-16/+72"
LCE7-13/M1801
LCE7-17/F2700
LN4-73
M1803/+60"
LN4-5
EP101
LN4-75 LN4-75
LN4-34/+72"
LCE7-18,20,22/S5505
LN4-80/SKYFACTORY
WINDOW
LN4-80/SKYFACTORY
WINDOW
LN4-79/SKYFACTORY
WINDOW
LN4-78/SKYFACTORY
WINDOW
LN4-78/SKYFACTORY
WINDOW
LN4-78/SKYFACTORY
WINDOW
LCE7-7/S0005
MX-S0941
MX-S0941
MX-S0941
MX-S0941
MX-S0942
LN4-71
S3185 AUTO DRAIN
VALVE
LN4-82
S1905
QL3-14,16
SSIU-2,INDOOR UNIT
QL3-13
EYE WASH (P-707)
QL3-15/EYE WASH
(P-707)
QL3-17/EYE WASH
(P-707)
QL3-20
CONDENSATE PUMP
LN4-81
3 3 3 3
LN6B-34
HEAT TRACE
LN6B-34
HEAT TRACE
LN6B-32
HEAT TRACE
LN6B-32
HEAT TRACE
LN6B-32
HEAT TRACE
LN6B-32
HEAT TRACE
LN4-84
+48"
LCE7-35
DOOR OPERATOR
LCE7-35
DOOR OPERATOR
LCE7-35
DOOR OPERATOR
LCE7-35
DOOR OPERATOR
LCE7-35
DOOR OPERATOR
LCE7-35
DOOR OPERATOR
LCE7-36
DOOR OPERATOR
LCE7-36
DOOR OPERATOR
LCE7-36
DOOR OPERATOR
LCE7-36
DOOR OPERATOR
LCE7-36
DOOR OPERATOR
LCE7-36
DOOR OPERATOR
LCE7-36
DOOR OPERATOR
5 5
LCE7-36
DOOR OPERATOR
LCE7-35
DOOR OPERATOR
LCE7-35
DOOR OPERATOR
6 AD-3
AD-3
AD-3
EQUIP. NUMBER DESCRIPTION VOLTAGE PHASE AMPS VA TYPE RECEPTACLE
F2700 BAR CODE READER 120V 1 200VA PLUG NEMA 5-20R
M1801 COMPUTER WITH FLAT PANEL MONITOR 120V 1 300VA PLUG NEMA 5-20R
M1803 WALL MOUNTED COMPUTER WORKSTATION 120V 1 300VA PLUG NEMA 5-20R
M3160 MEDIVATOR 120V 1 0.7A 85VA PLUG NEMA 5-20R
R7250 REFRIGERATOR 120V 1 800VA PLUG NEMA 5-20R
S0002 READER 390 120V 1 200VA PLUG NEMA 5-20R
S0003 SCANNER CHARGING STATION 120V 1 600VA PLUG NEMA 5-20R
S0004 INCUBATOR 120V 1 500VA PLUG NEMA 5-20R
S0005 BATTERY CHARGING STATOPM 120V 1 500VA PLUG NEMA 5-20R
S0007 ULTROSONIC CLEANER 120V 1 1000VA PLUG NEMA 5-20R
S0046 STERIS AMSCO DRYING CABINET 120V 1 1500VA PLUG NEMA 5-20R
S0442 AMSCO 600 STEAM STERLISER 480V 3 7A 5820VA E-CONN.
S0940 STERIS AMSCO 7052HP WASHER / DISINFECTOR 480V 3 34.5A 28682VA E-CONN.
S0941 STERIS WASHER / DISINFECTOR CONVEYOR SYSTEM 120V 1 12.5A 1500VA PLUG NEMA 5-20R
S0942 STERIS MOTORIZED RETURN CONVEYOR SYSTEM WITH DOOR 120V 1 12.5A 1500VA PLUG NEMA 5-20R
S1905 STERRIS AUTOMATED PASS THOUGH WINDOW 34"x45" 120V 1 1A 120VA PLUG NEMA 5-20R
S2627 ADVANTAGE PLUS PASS-THRU ENDOSCOPE REPROSSER 120V 1 10A 1200VA PLUG NEMA 5-20R
S2635 INNOWAVE ULTRASONIC IRRIGATOR & CLEANER 208V 3 15A 5403VA PLUG NEMA L15-20R
S3185 STERIS VISSION 1327 CART AND UTENSIL WASHER 480V 3 13.5A 11224VA E-CONN.
S5505 STERIS AMSCO V-PRO MAX LOW TEMP STERILIZER 208V 3 16A 5764VA PLUG NEMA L15-20R
S9610 AMSCO PREP AND PACK WORK STATION 36' X 72" (ELECTRIC) 120V 1 15A 1800VA PLUG NEMA 5-20R
250S30
A3
CORRIDOR
C52
ELECTRICAL
H3
QL3-10,12
SSIU-1
LN4-58
+42"
QH3
PANEL LN4
TLN4
DISTRIBUTION PANEL HN5
PANEL QL3
TQL3
TLCE7
PANEL LCE7DS-SSUI-1
QL3-18
CONDENSATE PUMP
SEE 'PARTIAL ENLARGED PLAN-GROUND
LEVEL', SHEET 1/EP102, FOR CONTINUATION
EXTEND FEEDER THROUGH
GROUND FLOOR LEVEL AND
CONNECT NEW DISTRIBUTION
PANEL 'HN6' AT LEVEL 1
MECH/ELEC 126C
CONNECT NEW TRANSFORMER
'TLCE7' AT GROUND FLOOR
CONNECT NEW DISTRUBUTION
PANEL 'HN5' AT GROUND
FLOOR
CONNECT NEW DISTRUBUTION
PANEL 'QH3' AT GROUND
FLOOR
FEEDER CIRCUITS ROUTED AT
STRUCTURAL CEILING OF EXISTING
BELOW GRADE PIPE SPACE. FIELD
COORDINATE ROUTING DEPENDENT
ON NEW AND EXISTING MECHANICAL
EQUIPMENT AND ASSOCIATED
PIPING. PROVIDE ADDITIONAL
JUNCTION/PULL/SPLICE BOXES AS
REQUIRED PER THE N.E.C. FASTEN
ALL FEEDERS SECURELY TO
BUILDING STRUCTURE.
SUGGESTED JUNCTION/PULL/SPLICE BOX
LOCATION INSTALLED AT LEVEL OF
PENETRATION INTO MECHANICAL PIPE
CHASE.
ROUTE FEEDER CONDUITS DOWN FROM
JUNCTION/PULL/SPLICE BOX INTO BELOW
GRADE PIPE SPACE.
I O W A
S E
D
PROFESS IONA
21081
L
IC
E N
L E
N G
I N E
E R
KRISTEN L.
SPINA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/1
.0
V A
-W a s h
D C
-V A
S io u x F a lls
N e w
S P
S /M
E P
T
.0
V A
W a s h D
C -V
A S io u x F a lls
N e w S
P S
C
.r v t
/1
/2
:2
:0
P
M
EP101
GROUND LEVEL FLOOR PLAN -
POWER
CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
07/17/2024 JMK JDR16584
REFERENCE SCALE IN INCHES
0 1 2 3
PROJECT #
IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS
DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE
THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR
REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF IMEG CORP. © 2025 IMEG CORP.
2882 106TH STREET
DES MOINES, IA 50322
515.334.9906 FAX: 515.334.9908
www.imegcorp.com
19004249.04
N O R
HT
1/8" = 1'-0"
GROUND LEVEL FLOOR PLAN - POWER
N O R
HT
1/4" = 1'-0"
MECHANICAL/ELECTRICAL ROOM - POWER
KEYNOTES:
1. INSTALL DIGITAL CAMERA SCREEN AT
REMOVED WINDOW LOCATION. SEE
ARCHITECTURAL DRAWINGS FOR
INFORMATION ON ROUGH OPENING WITH
HEADER POCKET. FROM LOCATION ABOVE OR
AT HEADER POCKET PROVIDE SURFACE
METAL RACEWAY WIREMOLD OR EQUAL TO
CONTROL STATION LOCATED ADJACENT TO
WINDOW. PROVIDE SURFACE METAL
RACEWAY FOR SPEAKER WIRES FROM
HEADER POCKET LOCATION UP TO CEILING
SPACE. LOCATE AND MOUNT SPEAKERS IN
GRID CEILING OR PROVIDE SURFACE
ENCLOSURE FOR SPEAKERS. PROVIDE
TOGGLE SWITCH NEAR EVERY WINDOW TO
SERVE AS DISCONNECT MEANS FOR POWER
TO LUMINAIRE. PROVIDE CONTROL STATION
FOR WAITING AREA WINDOW LUMINAIRE IN
RECEPTION AREA.
2. PROVIDE NEMA 15-20R GFI PROTECTED
RECEPTACLE LOCATED IN THE WALL BEHIND
ACCESS PANEL. COORDINATE EXACT
LOCATOINS OF ACCESS PANEL WITH
ARCHITECT AND EQUIPMENT SUPPLIER PRIOR
TO ROUGH-IN.
3. ELECTRICAL CONNECTION FOR HEAT TRACE IN
STORM PIPING. APPROXIMATELY 15 FEET OF
HEAT TRACE LOCATED INSIDE STORM PIPING.
REFER TO PLUMBING DRAWINGS FOR EXACT
LOCATION OF ROOF DRAINS AND ROOF DRAIN
BASINS. REFER TO DETAIL 3/E401 FOR HEAT
TAPE CONTROL DIAGRAM.
4. POWER OPERATED DOOR. COORDINATE
EXACT LOCATION WITH ARCHITECT.
5. DOOR PUSH PAD OPERATOR PROVIDED BY
G.C. AND INSTALLED BY E.C.. INSTALL CONDUIT
AND CONTROL WIRING PER MANUFACTURER'S
RECOMMENDATIONS.
6. PROVIDE SKY FACTORY MODEL 4726 WITH
CONTEMPORY, BRUSHED ALUMINUM TRIM.
REFER TO ARCHITECTURAL DRAWINGS FOR
SIZE REQUIREMENTS.
7. PROVIDE SKY FACTORY MODEL RE-AC-ALS-AL-
SNGL-5228-XX. REFER TO ARCHITECTURAL
DRAWINGS FOR SIZE REQUIREMENTS.
SHEET NOTES:
1. IT IS THE RESPONSIBILITY OF CONTRACTOR TO
VERIFY ALL EQUIPMENT AND REQUIRED
OPENINGS SHOWN ON THE DRAWINGS MATCH
WHAT EQUIPMENT IS ACTUALLY PROVIDED.
ANY CHANGES REQUIRED TO BE MADE IS THE
CONTRACTOR'S RESPONSIBILITY TO REVISE
DRAWINGS AS NEEDED, INCLUDING ANY
PROFESSIONAL ENGINEERING FEES
ASSOCIATED AND SHALL BE AT NO ADDITIONAL
COST TO THE VA.
N O R
HT
1/8" = 1'-0"
PIPE BASEMENT FLOOR PLAN - POWER
Revisions: Date:
Addendum 3 (AD-3) 05/20/2025
AD-3
| Sheets |
| EP101 - GROUND LEVEL FLOOR PLAN - POWER |
| EP111 - INTERSTITIAL/FIRST LEVEL FLOOR PLAN - POWER |
File details come from the government source that posted it. Updated .