S06 - Amend 0002 - RFP - Att 01-07 - DWG - 03242025 - SPS - Sioux Falls.pdf
PDF 10 MB Posted
- Solicitation number
- 36C77624R0115
About this file
These architectural drawing files (Drawing Numbers AE521, AE530, AE531, AE540, AE541, AE542, AE543, AE550, AE551, AE552, AE560, AE601, AE602, AF101, AF102, AF600, AW101, AW601, and QH101) detail the construction documents for a new Sterile Processing Services (SPS) addition at the Sioux Falls VA Health Care System. The project involves approximately 8,500 square feet of new construction and 2,300 square feet of renovation, located adjacent to the operating room addition in Building 5, with an interstitial/mechanical space matching the SPS space's footprint.
The drawings provide comprehensive architectural details including exterior and interior sections, wall and floor construction specifications, equipment placement, finishes, wayfinding signage, and equipment schedules. The project focuses on creating a specialized medical facility with specific requirements for sterile processing, featuring detailed specifications for areas like clean workrooms, decontamination spaces, steam sterilization zones, and scope processing rooms. Key equipment includes multiple steam sterilizers, washer/disinfectors, ultrasonic cleaners, drying cabinets, and specialized medical processing stations from manufacturers like STERIS Corporation and Cantel Medical. The drawings are prepared for the Department of Veterans Affairs Technology Acquisition Center Austin, with the solicitation number 36C77624R0115 and project number 438-460.
View the file
Other files
Show 40 more
Latest 50 of 61 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECOND LEVEL
123'-10"
A1
LOUVERED WEEP HOLES AT 16" OC
5/8" EXTERIOR SHEATHING
4" FACE BRICK
6" STUDS TYPE, GA AND SPACING
PER BLAST CONSULTANT
REQUIREMENTS
EXISTING WALL CONSTRUCTION
EXISTING WALL CONSTRUCTION
EXISTING FLOOR CONSTRUCTION
EXISTING STEEL BEAMS
PROVIDE SPRAY APPLIED FIREPROOFING
ON ALL EXISTING STEEL BEAMS IN THIS
AREA. SEE LIFESAFETY PLANS
SEALANTFILL CAVITY WITH BATT INSULATION
(NOT SHOWN)
WOOD BLOCKING AS REQUIRED
3/4" FIRE RATED PLYWOOD
3" RIGID INSULATION
3/4" FIRE RATED PLYWOOD
ELASTOMERIC SEETHING. SEAL
VAPOR TIGHT TO METAL DECK.
FLUID-APPLIED MEMBRANE AIR
BARRIER 3 5/8" METAL STUDS
PREFINISHED BREAK METAL FLASHING. FACE
FASTEN TO WOOD BLOCKING
SEALANT
SEALANT
6" STUDS TYPE, GA AND SPACING
PER BLAST REQUIREMENTS - SEE
STRUCTURAL
A1.0
SPS INTERSTITIAL LEVEL
113'-0"
B
ELASTOMERIC SHEETING - SEAL VAPOR
TIGHT TO TOP OF METAL FLASHING
FLUID-APPLIED MEMBRANE AIR BARRIER
SEE WALL SECTION AND WALL
TYPES FOR WALL
CONSTRUCTION
SEE SPECIFICATIONS AND
STRUCTURAL FOR BLAST
DESIGN REQUIREMENTS
COMPOSITE FLOOR SLAB - SEE STRUCTURAL
CAST STONE BAND. SEE SHEET AE602.
SHALL ALIGN WITH EXISTING.
STAINLESS STEEL CAST STONE PIN ANCHOR AT
VERTICAL JOINT IN CAST STONE
STAINLESS STEEL CAST STONE U STRAP
STAINLESS STEEL CAST STONE U STRAP
STAINLESS STEEL CAST STONE PIN ANCHOR AT
VERTICAL JOINT IN CAST STONE
WIDE FLANGE BEAM - SEE STRUCTURAL
SPRAY APPLIED FIRE PROOFING.
4"x4" CONCRETE CURB WITH 1" RADIUS
AND SLOPED TOP -SEE PLAN
EPOXY FINISH EXTEND UP CURB AND
SEAL TO WALL. - SEE PLANS
6" COLD FORMED STEEL STUDS TYPE,
GA AND SPACING PER BLAST
REQUIREMENTS - SEE STRUCTURAL
6" COLD FORMED STEEL STUDS TYPE,
GA AND SPACING PER BLAST
REQUIREMENTS - SEE STRUCTURALCAST STONE BAND. SEE SHEET AE602.
SHALL ALIGN WITH EXISTING.
3"x3"x3/16"x5" LONG STEEL ANGLE. SEE STRUCTURAL
3"x3"x3/16"x5" LONG STEEL ANGLE. SEE STRUCTURAL
1/4"x5" CONTINIOUS STEEL PLATE. SEE STRUCTURAL
5 1/2"x11"x5/16" BENT PLATE. SEE STRUCTURAL
SELANT
SPS INTERSTITIAL LEVEL
113'-0"
STAINLESS STEEL PREFINISHED METAL FLASHING
SEALANT
FLUID-APPLIED MEMBRANE AIR BARRIER
SEE WALL SECTION AND WALL
TYPES FOR WALL
CONSTRUCTION
ELASTOMERIC SHEETING . WRAP SHELF
ANGLE AND SEAL VAPOR TIGHT.
SEE SPECIFICATIONS FOR
BLAST DESIGN REQUIREMENTS
COMPOSITE FLOOR SLAB - SEE
STRUCTURAL
CAST STONE BAND. SEE SHEET AE602
STAINLESS STEEL CAST STONE PIN ANCHOR AT
VERTICAL JOINT IN CAST STONE
STAINLESS STEEL CAST STONE U STRAP
LOUVERED WEEP HOLES AT 16" OC
TREATED WOOD BLOCKING AS REQUIRED
4"x4" CIP CONCRETE CURB AND
SLOPED RAMP AT DOOR. SEE PLAN
REMOVABLE 1 1/2" x 1 1/2" SQUARE STEEL POST &
GUARD RAIL,SET IN SQUARE STEEL POCKET IN
CONCRETE CURB
3/8" X 10 1/4" GALV STEEL PLATE
DOOR SILL- SECURE TO METAL
STUDS
1/2" STEEL PLATE SHIM
DOOR AND FRAME AS SCHEDULED BLAST RESISTANT
CONNECTION FROM
DOOR FRAME SUPPORTING
STRUCTURE PER BLAST DESIGN
REQUIREMENTS. CONNECTION DESIGN BY
DOOR FRAME SUPPLIER TO MEET BLAST
PERFORMANCE REQUIREMENTS PER
SPECIFICATION SECTION 08 11 13.
ALUM THRESHOLD SET IN SEALANT
ELASTOMERIC SHEETING
TREATED WOOD BLOCKING
WIDE FLANGE BEAM - SEE STRUCTURAL
SPRAY APPLIED FIRE PROOFING.
5 1/2"x12"x1/4" BENT PLATE - SEE
STRUCTURAL
6" STUDS TYPE, GA AND SPACING PER
BLAST REQUIREMENTS - SEE
STRUCTURAL
3"x3"x3/16"x5" LONG STEEL ANGLE. SEE STRUCTURAL
SEALANT
WOOD BLOCKING
1 1/2" RIGID INSULATION
3/4" PLYWOOD SHEATHING
DRIP
SEALANT
5/8" EXTERIOR SHEATHING
ADHERED MEMBRANE ROOFING ON FIRE
TREATED 3/4" PLYWOOD SHEATHING ON
3" RIGID INSULATION
THERMOPLASTIC POLYOLEFIN (TPO)
MEMBRANE ROOFING EXTEND UP AND OVER
TOP OF PLYWOOD AND DOWN FACE OF
WOOD BLOCKING
TAPERED ROOF INSULATION
SLOPE
ELASTOMERIC SHEETING CAP
FLASHING
COPING WITH CONTINUOUS
CLEATS BOTH SIDES
END OF THERMOPLASTIC POLYOLEFIN (TPO)
DRIP
FILL CAVITY WITH BATT INSULATION
2 2
5" M
IN
7" M
IM
TY
P
1/
2" M
IN
SEE WALL SECTIONS AND WALL
TYPES FOR WALL CONSTRUCTION
CONTINUOUS SHEET VAPOR
RETARDER. EXTEND UP FACE OF
FIRE RATED PLYWOOD AND LAP
UNDER CAP FLASHING
WOOD BLOCKING
ELASTOMERIC SHEETING
SEALANT
6" STUDS TYPE, GA AND SPACING
PER BLAST REQUIREMENTS - SEE
STRUCTURAL
SECOND LEVEL
123'- 10"
SEE SPECIFICATIONS FOR
BLAST DESIGN REQUIREMENTS
1/2" COVER BOARD
THERMOPLASTIC
POLYOLEFIN (TPO)
MEMBRANE ROOFING
COMPOSITE SLAB - SEE
STRUCTURAL
UL LISTED FIRE STOP
ASSEMBLY
STEEL BEAM - SEE STRUCTURAL
TO PARAPET (LOW ROOF)
117'-1 1/4"
LOUVERED WEEP HOLES AT 16" OC
SPRAY APPLIED FIREPROOFING
5 1/2"x5 1/2"x5/16" BENT PLATE - SEE
STRUCTURAL
6" COLD FORMED STEEL STUDS TYPE, GA AND
SPACING PER BLAST REQUIREMENTS - SEE
STRUCTURAL
SEALANT
ROOF INSULATION. SEE ROOF PLAN
4" FACE BRICK
1'-9 1/4"
CAST STONE BAND. SEE SHEET AE602.
LOCATION SHALL ALIGN WITH EXISTING.
STAINLESS STEEL CAST STONE U STRAP
STAINLESS STEEL CAST STONE PIN ANCHOR AT
VERTICAL JOINT IN CAST STONE
6"x3 1/2"x5/16" STEEL ANGLE. SEE STRUCTURAL
WALL CONSTRUCTION
- 1 1/2" METAL PANEL (IW-15A)
- 3/4" METAL HAT CHANNELS
- FLUID APPLIED MEMBRANE AIR BARRIER
SYSTEM
EXISTING WALL CONSTRUCTION
EXISTING WALL CONSTRUCTION
EXISTING ROOF CONSTRUCTION
FU
LL
P
AN
EL
PRE FINISHED BREAK METAL TRIM TO MATCH PANEL
SHIM AS REQUIRED
SEALANT
N
EXISTING WALL CONSTRUCTION
TERMINATION BAR
METAL FLASHING W/ DRIP AND CONT KEEPER
ROOF MEMBRANE EXTEND UP FACE OF PLYWOOD
MEMBRANE ROOFING SYSTEM
3/4" PLYWOOD
3 1/2" RIGID INSULATION
ELASTOMERIC SHEETING OVER THROUGH WALL
FLASHING AND EXTEND UP BEHIND METAL
PANEL TO TERMINATION BAR
PREFINISHED/ MANUFACTURED EXPANSION JOINT
AND COVER.
PRE FINISHED BREAK METAL TRIM TO MATCH PANEL
SHIM AS REQUIRED
COMPOSITE SLAB - SEE
STRUCTURAL
N
2X4 NOMINAL WOOD
BLOCKING
COMPRESSIBLE INSULATION
ELASTOMERIC SHEETING EXTEND UP TO
TERMINATION BAR AND UP AND OVER WOOD
BLOCKING 1/2" COVER BOARD
TAPERED ROOF INSULATION
ELASTOMERIC SHEETING EXTEND UP FACE OF
PLYWOOD AND LAP OVER WOOD BLOCKING
CONTINUOUS SHEET VAPOR
RETARDER
SEALANT
WALL CONSTRUCTION
- 1 1/2" METAL PANEL (IW-15A)
- 3/4" METAL HAT CHANNELS
- FLUID APPLIED MEMBRANE AIR BARRIER SYSTEM
PROVIDE UL RATED 2 HOUR
EXPANSION JOINT MATERIAL.
CONTINUOUS
SPS INTERSTITIAL LEVEL
113' - 0"
2"
STEEL BEAM -SEE STRUCTURAL
SPRAY APPLIED FIREPROOFING
5 1/2"x3"x1/4" LLV BENT PLATE. - SEE
STRUCTURAL
E
3"x3"x1/4" STEEL ANGLES -SEE
STRUCTURUAL
2 4
2 4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:0
P
M
AE521
EXTERIOR SECTION DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"3 SECTION DETAIL - SOFFIT AT EXISTING ADDITION
1 1/2" = 1'-0"1 SECTION DETAIL - STONE BAND & SLAB EDGE
1 1/2" = 1'-0"4 SECTION DETAIL - INTERSTITAL DOOR SILL AND STONE BAND
1 1/2" = 1'-0"2 SECTION DETAIL - PARAPET AT BRICK WALL WITH METALS STUD - LOW ROOF
1 1/2" = 1'-0"5 SECTION DETAIL - METAL PANEL AT PARAPET
1 1/2" = 1'-0"6 SECTION DETAIL - METAL PANEL BASE @ LOW ROOF GRID N
Revisions: Date:
CL CL
OVERFLOW DRAIN
TAPER INSULATION DOWN TO
DRAIN. MIN INSUL R-VALUE AT ROOF
DRAINS R-15
CLAMPING RING
DRAIN LEADER. SEE
MECHANICAL
COMPOSITE ROOF DECK.
SEE STRUCTURAL
PRIMARY DRAIN - EXACT
PROFILE OF DRAIN ELEMENTS
MAY VARY
ROOFING MEMBRANE OVER
COVER BOARD
VAPOR RETARDER -
SEAL TO ROOF
MEMBRANE
ROOFING MEMBRANE
CONTINUOUS BEAD OF
WATER CUTOFF MASTIC, FULL
WIDTH OF CLAMPING RING,
TYP
RUST-RESISTANT BOLTS, TYP
CLOSED CELL LOW EXPANSION SPRAY FOAM
INSULATION
1'-2" 2'-0"
COVER BOARD
ROOFING MEMBRANE. EXTEND TO
EDGE OF WOOD BLOCKING BENEATH
CURB FLANGE
INSULATED METAL HATCH CURB ANCHORED TO
WOOD BLOCKING, SET ANCHORING FLANGE IN
FULL BED OF WATER BLOCK MASTIC ON TOP OF
ROOFING MEMBRANE
COMPOSITE ROOF DECK, SEE
STRUCTURAL
STEEL FRAMING, SEE
STRUCTURAL
SPRAY APPLIED FIREPROOFING AT
BEAMS
BENT PLATE
CLOSURE, SEE
STRUCTURAL
VAPOR RETARDER EXTEND
TO EDGE OF WOOD
BLOCKING BENEATH
ROOFING MEMBRANE
LAP SEALANT/SPLICE TAPE
SEALANT AND BACKER ROD
TREATED WOOD BLOCKING DEPTH TO
MATCH INSULATION THICKNESS,
EXTEND BEYOND OUTER EDGE OF
CUR ANCHORING FLANGE 1" MIN
TREATED PLYWOOD
SHEATHING OVER
BLOCKING
EPDM MEMBRANE FLASHING BONDED TO CURB
AND SPLICED TO ROOFING MEMBRANE - EXACT
CONDITION OF ROOFING MEMBRANE SEAL AT
CURB MAY VARY EXTEND CURB
FLASHING UP HATCH
WALL & FASTEN PER
MANUFACTURER
RECOMMENDATIONS
EXISTING WALL CONSTRUCTION -SEE PLAN
SPONGE TUBING
COMPRESSIBLE INSULATION
3/4" PLYWOOD
2X WOOD BLOCKING
RIGID INSULATION
UL RATED 2 HOUR EXPANSION JOINT MATERIAL
KERF CUT INTO EXISTING BRICK
SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
ELASTOMERIC SHEETING.. EXTEND UP FACE OF BRICK
PREFINISHED MANUFACTURED
EXPANSION JOINT COVER
MEMBRANE ROOF EXTEND UP
FACE OF PLYWOOD AND OVER
WOOD BLOCKING.
ELASTOMERIC SHEETING. EXTEND OVER WOOD
BLOCKING AND DOWN FACE OF PLYWOOD
PREFINISHED BREAK METAL REGLET
COMPOSITE ROOF DECK - SEE STRUCTURAL
TAPERED ROOF INSULATION -
SEE ROOF PLAN
CONTINUOUS SHEET VAPOR RETARDER. EXTEND UP
FACE OF FIRE RATED PLYWOOD AND LAP UNDER CAP
FLASHING
1/2" COVER BOARD
SPS INTERSTITIAL LEVEL
113'-0"
FIRST LEVEL
111'-11"
AREA OF REMOVED STONE BAND SEE
DEMOLITION PLANS AND SECTIONS.
AREA OF REMOVED BRICK SEE DEMOLITION PLANS
AND SECTIONS.
CMU INFILL AT REMVOED STONE BAND.
GROUT SOLID AS REQUIRED
2 4
2 4
4" M
IN
5 1/2"x3"X5/16" BENT PLATE - SEE STRUCTURAL
WIDE FLANGE BEAM - SEE STRUCTURAL
SPRAY APPLIED FIRE PROOFING
FIRST LEVEL
111'-11"
SPS INTERSTITIAL LEVEL
113'-0"
2 4
2 4
BACKER ROD AND SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
PREFINISHED BREAK METAL FLASHING
PREFINISHED MANUFACTURED EXPANSION
JOINT COVER W/ DRIP AND CONT KEEPER
MEMBRANE ROOF EXTEND UP
FACE OF PLYWOOD AND OVER
WOOD BLOCKING.
ELASTOMERIC SHEETING. EXTEND OVER WOOD
BLOCKING AND DOWN FACE OF PLYWOOD
COMPOSITE ROOF DECK - SEE
STRUCTURAL
TAPERED ROOF INSULATION -
SEE ROOF PLAN
CONTINUOUS SHEET VAPOR
RETARDER. EXTEND UP FACE OF FIRE
RATED PLYWOOD AND LAP UNDER CAP
FLASHING
8" M
IN
1"
XN3
CAST IN PLACE CONCRETE WALL.
SEE STRUCTURAL
EXISTING FLOOR
CONSTRUCTION -SEE
STRUCTURAL
J4cs
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL. CONTINUOUS
EXPANSION JOINT. SEE
STRUCTURAL
SEALANT
SOLID SURFACE SILL
PRIMARY SEAL
ELASTOMERIC SHEETING. SEAL VAPOR TIGHT
TO CONCRETE. MUST EXTEND BACK TO
PRIMARY SEAL
SEALANT
BACKER ROD AND SEALANT
EXISTING MULTI LEVEL CURTAIN
WALL.
4" M
IN
EXISTING WALL CONSTRUCTION -
SEE PLAN
SPONGE TUBING
COMPRESSIBLE INSULATION
3/4" PLYWOOD
2X WOOD BLOCKING
RIGID INSULATION
2 4
2 4
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL
KERF CUT INTO EXISTING BRICK
SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
ELASTOMERIC SHEETING.. EXTEND UP
FACE OF BRICK
PREFINISHED MANUFACTURED EXPANSION
JOINT COVER W/ DRIP AND CONT KEEPER
MEMBRANE ROOF EXTEND UP
FACE OF PLYWOOD AND OVER
WOOD BLOCKING.
ELASTOMERIC SHEETING. EXTEND OVER WOOD
BLOCKING AND DOWN FACE OF PLYWOOD
PREFINISHED BREAK METAL REGLET
COMPOSITE ROOF DECK - SEE STRUCTURAL
TAPERED ROOF INSULATION -
SEE ROOF PLAN
CONTINUOUS SHEET VAPOR RETARDER. EXTEND UP
FACE OF FIRE RATED PLYWOOD AND LAP UNDER CAP
FLASHING
4" M
IN
1/2" COVER BOARD
SPS INTERSTITIAL LEVEL
113'-0"
FIRST LEVEL
111'-11"
AREA OF REMOVED STONE BAND SEE
DEMOLITION PLANS AND SECTIONS.
AREA OF REMOVED BRICK
SEE DEMOLITION PLANS AND
SECTIONS.
CMU INFILL AT REMVOED STONE BAND. -SEE
STRUCTURAL
GROUT SOLID AS REQUIRED
5 1/2"x3"X5/16" BENT PLATE - SEE STRUCTURAL
WIDE FLANGE BEAM - SEE STRUCTURAL
SPRAY APPLIED FIRE PROOFING
EXISTING WINDOW -SEE PLAN
EXISTING WALL CONSTRUCTION
SPONGE TUBING
COMPRESSIBLE INSULATION
3/4" PLYWOOD
2X WOOD BLOCKING
RIGID INSULATION
UL RATED 2 HOUR EXPANSION JOINT MATERIAL
KERF CUT INTO EXISTING BRICK
SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
ELASTOMERIC SHEETING.. EXTEND UP FACE OF
BRICK
PREFINISHED MANUFACTURED EXPANSION
JOINT COVER W/ DRIP AND CONT KEEPER
MEMBRANE ROOF EXTEND UP
FACE OF PLYWOOD AND OVER
WOOD BLOCKING.
ELASTOMERIC SHEETING. EXTEND OVER WOOD
BLOCKING AND DOWN FACE OF PLYWOOD
PREFINISHED BREAK METAL REGLET
COMPOSITE ROOF DECK - SEE STRUCTURAL
TAPERED ROOF INSULATION - SEE
ROOF PLAN
CONTINUOUS SHEET VAPOR RETARDER. EXTEND UP
FACE OF FIRE RATED PLYWOOD AND LAP UNDER CAP
FLASHING
1/2" COVER BOARD
SPS INTERSTITIAL LEVEL
113'-0"
OR ROOF LEVEL
116'-0"
2 4
2 4
8" M
IN
5 1/2"x9"X5/16" BENT PLATE - SEE STRUCTURAL
WIDE FLANGE BEAM - SEE STRUCTURAL
SPRAY APPLIED FIRE PROOFING
SBH
2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:0
P
M
AE530
ROOF DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"1 SECTION DETAIL - ROOF DRAINS
1 1/2" = 1'-0"2 ROOF DETAIL - ROOF HATCH CURB
1 1/2" = 1'-0"3 ROOF DETAIL - MEMBRANE ROOF @ EXISTING BRICK
1 1/2" = 1'-0"4 ROOF DETAIL - ROOF ANT MODIFIED CURTIAN WALL
1 1/2" = 1'-0"5 ROOF DETAIL - MEMBRANE ROOF @ FIRST LEVEL WINDOW
1 1/2" = 1'-0"6 ROOF DETAIL - MEMBRANE ROOF @ OPERATING ROOM SUITE
EXISTING WALL CONSTRUCTION -
SEE PLAN
SPONGE TUBING
COMPRESSIBLE INSULATION
3/4" PLYWOOD
2X WOOD BLOCKING
RIGID INSULATION
2 4
2 4
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL
KERF CUT INTO EXISTING BRICK
SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
ELASTOMERIC SHEETING.. EXTEND UP
FACE OF BRICK
PREFINISHED MANUFACTURED EXPANSION
JOINT COVER W/ DRIP AND CONT KEEPER
MEMBRANE ROOF EXTEND UP
FACE OF PLYWOOD AND OVER
WOOD BLOCKING.
ELASTOMERIC SHEETING. EXTEND OVER WOOD
BLOCKING AND DOWN FACE OF PLYWOOD
PREFINISHED BREAK METAL REGLET
COMPOSITE ROOF DECK - SEE STRUCTURAL
TAPERED ROOF INSULATION - SEE
ROOF PLAN
CONTINUOUS SHEET VAPOR RETARDER. EXTEND UP
FACE OF FIRE RATED PLYWOOD AND LAP UNDER CAP
FLASHING
8" M
IN
1/2" COVER BOARD
SECOND LEVEL
123'-10"
5 1/2"x3"X5/16" BENT PLATE - SEE STRUCTURAL
WIDE FLANGE BEAM - SEE STRUCTURAL
SPRAY APPLIED FIRE PROOFING
EXISTING WINDOW -SEE PLAN
D O
EXISTING WALL CONSTRUCTION -
SEE PLAN
SPONGE TUBING
COMPRESSIBLE INSULATION
3/4" PLYWOOD
2X WOOD BLOCKING
RIGID INSULATION
2 4
2 4
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL
KERF CUT INTO EXISTING BRICK
SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
ELASTOMERIC SHEETING.. EXTEND UP
FACE OF BRICK
PREFINISHED MANUFACTURED EXPANSION
JOINT COVER W/ DRIP AND CONT KEEPER
MEMBRANE ROOF EXTEND UP
FACE OF PLYWOOD AND OVER
WOOD BLOCKING.
ELASTOMERIC SHEETING. EXTEND OVER WOOD
BLOCKING AND DOWN FACE OF PLYWOOD
PREFINISHED BREAK METAL REGLET
COMPOSITE ROOF DECK - SEE STRUCTURAL
TAPERED ROOF INSULATION - SEE
ROOF PLAN
CONTINUOUS SHEET VAPOR RETARDER. EXTEND UP
FACE OF FIRE RATED PLYWOOD AND LAP UNDER CAP
FLASHING
8" M
IN
1/2" COVER BOARD
SECOND LEVEL
123'-10"
5 1/2"x9"X5/16" BENT PLATE - SEE STRUCTURAL
WIDE FLANGE BEAM - SEE STRUCTURAL
SPRAY APPLIED FIRE PROOFING
D O
EXISTING WALL CONSTRUCTION -
SEE PLAN
SPONGE TUBING
COMPRESSIBLE INSULATION
3/4" PLYWOOD
2X WOOD BLOCKING
RIGID INSULATION
2 4
2 4
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL
KERF CUT INTO EXISTING BRICK
SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
ELASTOMERIC SHEETING.. EXTEND UP
FACE OF BRICK
PREFINISHED MANUFACTURED EXPANSION
JOINT COVER W/ DRIP AND CONT KEEPER
MEMBRANE ROOF EXTEND UP
FACE OF PLYWOOD AND OVER
WOOD BLOCKING.
ELASTOMERIC SHEETING. EXTEND OVER WOOD
BLOCKING AND DOWN FACE OF PLYWOOD
PREFINISHED BREAK METAL REGLET
COMPOSITE ROOF DECK - SEE STRUCTURAL
TAPERED ROOF INSULATION - SEE
ROOF PLAN
CONTINUOUS SHEET VAPOR RETARDER. EXTEND UP
FACE OF FIRE RATED PLYWOOD AND LAP UNDER CAP
FLASHING
8" M
IN
1/2" COVER BOARD
SECOND LEVEL
123'-10"
5 1/2"x3"X5/16" BENT PLATE - SEE STRUCTURAL
EXISTING WIDE FLANGE BEAM - SEE STRUCTURAL
SPRAY APPLIED FIRE PROOFING
30.1 OS
WIDE FLANGE BEAM - SEE STRUCTURAL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:1
P
M
AE531
ROOF DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"1 ROOF DETAIL - MEMBRANE ROOF @ EXISTING SECOND LEVEL WINDOW
1 1/2" = 1'-0"2 ROOF DETAIL - MEMBRANE ROOF @ EXISTING SECOND LEVEL
1 1/2" = 1'-0"3 ROOF DETAIL - MEMBRANE ROOF @ INPATIENT ADDITION - GRID OS
HSS 6" x 2" x 1/4" WELDED
TO BOTTOM PLATE WITH
3/16" WELD
3 5/8" x 12" x1/4"
STEEL PLATE TOP &
BOTTOM. FASTEN TOP
PLATE TO STRUCTURE
ABOVE W/ 5/8" DIA EXP
BOLT TO CONCRETE OR
WELD TO STEEL
GRAB BAR
5/8" EXP BT
FOR CONCRETE WALL FINISH AS
SCHEDULED
SEE FLOOR PLANS FOR PARTITION TYPE
METAL SLEEVE
MOUNTING BRACKET
PLAN
SECTION
2"
HSS 6" x 2" x 1/4"
12" x 3 5/8" x 1/4" STEEL PLATE
2" x 2" x 1/4" STEEL CLIP
ANGLE EACH SIDE
STRUCT ABOVE
TUBE STEEL TS 3 X 3 X 1/4"
STEEL BASE
PLATE 9" X 9" X
1/4"
END PARTITION
DOUBLE STUD
HALF HEIGHT PARTITION-
SEE FLOOR PLAN AND
PARTITION TYPES FOR
ADDITIONAL INFORMATION
GYP BD RETURN
AT END OF
PARTITION
GYP BD RETURN AT
TOP OF PARTITION
TOP OF STEEL
TUBE
TUBE STEEL -
SEE ABOVE
FLOOR FEATHER
MATERIAL TO TOP
OF BASE PLATE
FIN FLOOR
BASE PLATE -SEE
ABOVE
METAL STUD RUNNER
SECTION VIEW
PLAN VIEW
METAL STUD RUNNER
1/
2"
TY
P
1 1/2"TYP
CL
C L
CL
2"
M
SE
E
EN
LA
RG
ED
P
LA
N
XN3
XN3
XN3
XN3
XN3
8 1/4"
AREA OF BRICK ABOVE
EQUIPMENT LOCATION. SEE
EQUIPMENT PLANS
EXISTING WALL
CONSTRUCTION
SEALANT. ALL SIDES AT
EQUIPMENT FLANGE
E
1.7
N
1' -4
/2
9"
1' -4
/2
2'
-4
/8
J2c
J2c
XN
XN3
XN3
J2 c
J4c
EXISTING CONCRETE FOUNDATION
WALL BELOW. FACE BRICK AND CMU
ABOVE. FIELD VERIFY
5"x5"x3/8" HSS - SEE STRUCTURAL
1/
8"
3/ 4"
1'-4" 1'-4 1/8"
7 1/2"
7/
8"
3/ 8"
EXTEND TO RATED HORIZONTAL
SHAFT WALL ENCLOSURE ABOVE
J2c
J2 c
E
N
XN3
XN3
J2c
EXISTING CONCRETE FOUNDATION
WALL BELOW. FACE BRICK AND CMU
ABOVE. FIELD VERIFY
AE551
ABOVE CEILING
D
XP3
DOOR AND FRAME AS
SCHEDULED
1'- 2"
6"x6"x3/8" HSS - SEE STRUCTURAL
EXISTING WALL
CONSTRUCTION
9 3/8" 11 1/4"
SPRAY APPLIED FIREPROOFING
XN
XN3
XN3
B3 XN3
4"x4"x3/8" HSS - SEE STRUCTURAL
SPRAY APPLIED FIREPROOFING
8"x8"x1/2" BASE PLATE - SEE
STRUCTURAL
4"x4"x3/8" HSS - SEE STRUCTURAL
SPRAY APPLIED FIREPROOFING
8"x8"x1/2" BASE PLATE - SEE
STRUCTURAL
XN
XN3
B3
XN
O
XN
DOOR AND FRAME AS
SCHEDULED. CENTER
DOOR AND FRAME IN
OPENING.
XN7
EQ
XN
3/
4" 1'
-5
/4
EXISTING WALL
CONSTRUCTION
O
DOOR AND FRAME AS SCHEDULED. CENTER
DOOR AND FRAME IN OPENING.
XN
EQ
XP
1' -5
/4
3/ 4"
XN7
EXISTING WALL
CONSTRUCTION
M
XN3
XN3
1' -2
/4
XN
B3
XP3
B3
EXISTING COLUMN - SEE STRUCTURAL
1'-2 1/4" 1'-2 1/4"
M
XN3
XN3
1' -2
/4
XN
B3
XP3
B3
EXISTING COLUMN - SEE STRUCTURAL
1'-2 1/4" 1'-2 1/4"
8"
PROVIDE BLOCKING IN PARTITION FOR
WALL MOUNTED COMPUTER.
COORDINATE WITH EQUIPMENT
DRAWINGS AND COR.
OPENING FOR ENDOSCOPE
REPROCESSING SYSTEM. SEE
EQUIPMENT DRAWINGS. COORDINATE
WITH EQUIPMENT MANUFACTURER.
OPENING FOR ENDOSCOPE
REPROCESSING SYSTEM. SEE
EQUIPMENT DRAWINGS. COORDINATE
WITH EQUIPMENT MANUFACTURER.
11"
M
XP3
XN3
2' -3
/2
XN
B3
XP3
EXISTING COLUMN - SEE STRUCTURAL
1'-2 1/4"
2'-6 1/2"
B3
COUNTERTOP, BACK AND SIDE SPLASH AND
CASEWORK BELOW. SEE ELEVATIONS &
PLAN
1'-0" B3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:1
P
M
AE540
INTERIOR PLAN DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
3" = 1'-0"2 DETAIL - GRAB BAR SUPPORT - STEEL
1 1/2" = 1'-0"1 INTERIOR DETAIL - PARTIAL HEIGHT PARTITION-STEEL SUPPORT
1 1/2" = 1'-0"3 PLAN DETAIL - PARTITION OPENING AT STEAM STERILIZER
1 1/2" = 1'-0"5 PLAN DETAIL - PARTITION AT OPENING IN STAIR TOWER FOUNDATION - NORTH
1 1/2" = 1'-0"6 PLAN DETAIL - PARTITION AT OPENING IN STAIR TOWER FOUNDATION - SOUTH
1 1/2" = 1'-0"4 PLAN DETAIL - PARTITION @ COLUMN D-23
1 1/2" = 1'-0"7 PLAN DETAIL - PARTITION AND DOOR JAMB AT DOOR H26B
1 1/2" = 1'-0"8 PLAN DETAIL - PARTITION AND DOOR JAMB AT DOOR H20AA
1 1/2" = 1'-0"9 PLAN DETAIL - PARTITION @ COLUMN M-22
1 1/2" = 1'-0"10 PLAN DETAIL - PARTITION @ COLUMN M-23
1 1/2" = 1'-0"11 PLAN DETAIL - PARTITION @ COLUMN M-24
D
XP3
/4
O
6"x6"x3/8" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
XP2
6 1/2"
6 1/2" 1'-2 1/2"
EXISTING WALL
CONSTRUCTION
B3
XP3
XP2
XP3
4"x4"x3/8" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
8"x8"x1/2" BASE
PLATE - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
1'-1"
4"x4"x3/8" HSS - SEE
STRUCTURAL
8"x8"x1/2" BASE
PLATE - SEE
STRUCTURAL
D
XP3
DOOR AND FRAME AS
SCHEDULED
/4
O
XP
J4cs
6"x6"x1/2" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
1'-4 3/4"
4"x4"x3/8" HSS - SEE
STRUCTURAL
SPRAY APPLIED FIREPROOFING
EXISTING WALL
CONSTRUCTION
5"
2' -5
/2
5"
UL RATED EXPANSION JOINT
MATERIAL CONTINUOUS. SEE LIFE
SAFETY PLANS FOR PARTITION
RATING
J2cs
8"x8"x1/2" BASE PLATE - SEE
STRUCTURAL
J4 cs
J2 cs
ALIGN
C
XP3
1' -0
/2
8"
B3 B3
EQ EQ
1'-8 1/2"
XP3
XP3
XP
1/
4"
8"x8"x3/8" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
C
B3
1/
4"
S-__ SILL / STOOL BELOW
ALUMINUM STORE FRONT SYSTEM. SEE
PLAN FOR ADDITIONAL INFORMATION
BACKER ROD AND SEALANT BOTH SIDES
EQ
EQ
C
XP3
1' -0
/2
8"
B3
B3
EQ EQ
1'-8 1/2"
XP3
XP3
XP
/4
3/
8"
8"x8"x1/2" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
A1
XP3
DOOR AND FRAME AS
SCHEDULED
XP
XP3
J4cs
4"
E3 c
6'-0"
5' -2
/8
EXISTING CONCRETE
PIER. -SEE STRUCTURAL
XP
STEEL COLUMN -SEE STRUCTURAL
SPRAY APPLIED FIREPRROFIN
SB
CARD READER. SEE ELECTRICAL
XN2
XN2
XN7
J4 cs
B3bs
/8
EXISTING WALL CONSTRUCTION
SB
CARD READER. SEE ELECTRICAL
J4 cs
DOOR AND FRAME AS SCHEDULED
XP2
XN7
H
5/ 8"
4"
10" METAL STUD FRAMING
5/8" GYP BD
1/2" GYP BD
1/2" GYP BD
0S A2
E3c
XN3
XN3
XN3
1/
4"
2'-4 1/2"
EQ
EQ
SPRAY APPLIED FIREPROOFING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:1
P
M
AE541
INTERIOR PLAN DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"1 PLAN DETAIL - PARTITION @ COLUMN O-24
1 1/2" = 1'-0"2 PLAN DETAIL - PARTITION @ COLUMN O-25
1 1/2" = 1'-0"3 PLAN DETAIL - PARTITION @ COLUMN C-4 (TYP)
1 1/2" = 1'-0"4 PLAN DETAIL - INTERIOR ALUM STOREFRONT JAMB (TYP)
1 1/2" = 1'-0"5 PLAN DETAIL - PARTITION @ COLUMN C-2
1 1/2" = 1'-0"6 PLAN DETAIL - PARTITION @ EXISTING CONCRETE PIER
1 1/2" = 1'-0"7 PLAN DETAIL - PARTITION / DOOR JAMB @ OPENING TO OR SUITE
1 1/2" = 1'-0"8
PLAN DETAIL - PARTITION / DOOR JAMB @ OR SUITE WITH
WINDOW INFILL
1 1/2" = 1'-0"9 PLAN DETAIL - PARTITION @ COLUMN A2-0S
0S A2.9
XN3
XN3
XN3
1/
4"
2'-3"
EQ
EQ
1'- 9"
EXISTING STEEL COLUMN SEE STRUCTURAL
SPRAY APPLIED FIRE
PROOFING. SEE LIFE SAFETY
PLANS
XN3
EXISTING WALL
CONSTRUCTION
J4c
E3c
SEALANT
REMOVE PORTION OF
DOOR SILL
DOOR FRAME TO
REMAIN
ALIG
N
ALIGN
EXISTING WALL
CONSTRUCTION
J4c
UL RATED EXPANSION JOINT
MATERIAL CONTINUOUS. SEE LIFE
SAFETY PLANS FOR PARTITION
RATING
ALUMINUM PLATE EXPANSION JOINT COVER SEE STRUCTURAL
EXP JT
CONCRETE CURB BELOW. SEE PLANS AND SECTIONS
CONCRETE CURB BELOW. SEE PLANS AND SECTIONS
EXISTING WALL
CONSTRUCTION
J4 C
UL RATED EXPANSION JOINT
MATERIAL CONTINUOUS. SEE LIFE
SAFETY PLANS FOR PARTITION
RATING
ALUMINUM PLATE EXPANSION JOINT COVER
CONCRETE CURB BELOW. SEE PLANS AND SECTIONS
CONCRETE CURB BELOW. SEE PLANS AND SECTIONS
N
EXISTING WALL CONSTRUCTION EXISTING CONCRETE
COLUMN - SEE
STRUCTURAL
EXISTING WALL
CONSTRUCTION
J4c
EXISTING COLUMN
0S A3.5
MA8
3/
" 1'-3 7/8"
J4c
L
XN3
G
ALIGN
XN
XN3
4"x4"x1/4" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
EXISTING WALL
CONSTRUCTION
J4cs XN7
1'-0 1/2"
4"x4"x3/8" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
XN
8"x8"x1/2" BASE
PLATE - SEE
STRUCTURAL
G
4.9
DOOR AND FRAME AS
SCHEDULED
XP3XP3 XP3XP3
XP3
1'-9 1/2"
/4
3/ 4"
5"x5"x1/4" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
EXISTING WALL
CONSTRUCTION
11 1/4"
EXISTING COLUMN SEE
STRUCTURAL
4"x4"x3/8" HSS - SEE
STRUCTURAL
SPRAY APPLIED FIREPROOFING
8"x8"x1/2" BASE PLATE - SEE
STRUCTURAL
XP3
L
1'-7 3/8"
G
4.3
XP3
1'-11 1/4"
B3
B3
XN
XN
EXISTING WALL
CONSTRUCTION
6 1/2"
G
XN3
XN3
1' -2
/2
9 1/2" 11 1/2"B3
XN
XN
XN
EXISTING WALL
CONSTRUCTION
L
5"x5"x3/8" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
4"x4"x3/8" HSS - SEE
STRUCTURAL
8"x8"x1/2" BASE PLATE -
SEE STRUCTURAL
SPRAY APPLIED
FIREPROOFING
O
4.3
XP3
1'-11 1/4"
B3
B3
XP3
XN3
D
EXISTING WALL
CONSTRUCTION
F
XN3
XN3
XN3
XN3
XN
31.7
5"x5"x3/8" HSS - SEE STRUCTURAL
J2c
J2c
J2 c
AL
IG
N
EXISTING CONCRETE FOUNDATION
WALL BELOW. FACE BRICK AND
CMU ABOVE. FIELD VERIFY
6 1/2"
1/
4"
1/ 2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:1
P
M
AE542
INTERIOR PLAN DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"1 PLAN DETAIL - PARTITION @ COLUMN A2.9-0S
1 1/2" = 1'-0"2 PLAN DETAIL - RATED PARTITION AT REMOVED DOOR
1 1/2" = 1'-0"3 PLAN DETAIL - RATED PARTITION AND EXPANSION JOINT AT EXISTING
1 1/2" = 1'-0"4 PLAN DETAIL - RATED PARTITION AND EXPANSION JOINT AT EXISTING STAIR
1 1/2" = 1'-0"5 PLAN DETAIL - RATED PARTITION AT COLUMN 0S-A3.5
1 1/2" = 1'-0"6 PLAN DETAIL - PARTITION @ COLUMN L-25
1 1/2" = 1'-0"7 PLAN DETAIL - PARTITION @ COLUMN G-4.9
1 1/2" = 1'-0"9 PLAN DETAIL - PARTITION @ COLUMN G-4.3
1 1/2" = 1'-0"10 PLAN DETAIL - PARTITION @ COLUMN G-23
1 1/2" = 1'-0"11 PLAN DETAIL - PARTITION @ COLUMN D-4.3
1 1/2" = 1'-0"12 PLAN DETAIL - PARTITION @ COLUMN F-1.7
WASHER - DISINFECTOR (S9040) OWNER
PROVIDED CONTRACTOR INSTALLED
MANUFACTURER BARRIER TRIM KIT
SEALANT BEAD BETWEEN PARTITION AND
MANUFACTURER BARRIER TRIM. SEAL AIR
TIGHT. BOTH SIDES
PROVIDE PARTITION TYPE 'B3" WHERE
POSSIBLE AT REMOVED EXTERIOR WALL/
OPENING FOR STEAM STERILIZER
SEALANT BEAD AT FLOOR LINE, BOTH SIDES.
SEAL AIR TIGHT
SEE PLAN FOR PARTITION TYPE
PROVIDE SEALANT BEAD AT
FLOOR LINE. SEAL AIR TIGHT
CART WASHER (S3185)
PROVIDE CONTINUOUS 18GA SST FLANGE
CONTINUOUS SEALANT BEAD
BEHIND SST FLANGE
SST FASTENERS AS REQUIRED
CONTINUOUS SEALANT BEAD
BEHIND SST FLANGE
6" MIN
6" M
IN
M
J4cs
EXISTING COLUMN -
SEE STRUCTURAL
1'-4 3/4"
J4 cs ALIGN
FIELD VERIFY EXISTING PARTITION
CONSTRUCTION
A1.7
30.4
E3c
XN3
5"x5"x1/4" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
1'-0"
9"
1'- 6"
EQ
EQ
XN3
XN3
A1.7
A1.0
E3c
XN
5"x5"x1/4" HSS - SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
XN3
XN3
- 3
'-6
/1 6"
8'-10"
1'-0"
SEE PLA
N
5 7 /8"
A2
OS
XN3
XN3
EXISTING STEEL
COLUMN - SEE
STRUCTURAL
PROVIDE SPRAY APPLIED
FIREPROOFING ON
EXISTING COLUMN
E3c
XN3
2'- 6"
2'-4 1/2"
EQ
EQ
5 7 /8"
45.00°
XN3
XN3
1'-4 3/4"
DIRTY SIDE
CLEAN SIDE
ENDOSCOPE PREPROCESSING SYSTEM (S2627)
SEE PLAN FOR PARTITION TYPE
VENTILATION OPENING
WATER/ AIR OPENING
ELECTRICAL / NETWORK OPENING
NOTE:
COORDINATE OPENING LOCATIONS AND SIZES WITH EQUIPMENT MANUFACTURER.
6"x2"x1/4" HSS WELDED
TO BOTTOM PLATE W/ 3/16" WELD
12"x3 5/8"x1/4" STEEL PLATE
TOP & BOTTOM. FASTEN TOP
PLATE TO STRUCT ABOVE W/
5/8" DIA EXP BOLT TO CONC
1'
0" P
LA
TE
5/8" EXP BOLT
FOR CONCRETE
WALL FINISH AS
SCHEDULED
SEE FLOOR PLAN FOR
PARTITION TYPE
METAL SLEEVE
PLAN VIEW
ELEVATION @
FLOOR STRUCT
ABOVE
2"
6"x2"x1/4" HSS
12"x4"x1/4" STEEL PLATE TOP
2"x2"x1/4" STEEL CLIP
ANGLE EA SIDE
STRUCTURE ABOVE
3/16
1/4" DIA BOLT WITH
THREADED INSERT AT STEEL
COLUMN
CONTINUOUS U SHAPED TOILET
PARTITION BRACKET
5/8" DIA EXP BOLT TO CONC
1" M
IN
4"
3/8" PLATE EACH SIDE, AT TOP WITH
1/2" DIA THROUGH BOLTS INTO
LONG VERTICAL SLOTS.
TOILET PARTITION
6"x2"x1/4" HSS WELDED
TO BOTTOM PLATE W/ 3/16" WELD
1/4" DIA THROUGH BOLT
AE560
FRONT VIEWSIDE VIEW
MC6 X 6.5 CONTINUOUS
IF MC6 IS NOT ATTACHED AT STEEL COLUMN PROVIDE
DIAGONAL BRACE AND TREADED ROD (TO STRUCTURE
ABOVE) AT END OF MC. SEE DETAILS
TOILET PARTITIONS. SEE PLAN(S) AND ELEVATION(S)
TREADED ROD. 2 MIN PER PILASTER
TOILET PARTITION PILASTER
CEILING AS SCHEDULED
TOILET PARTITIONS. SEE PLAN AND ELEVATION
CEILING AS SCHEDULED
TOILET PARTITION PILASTER
FINISHED FLOOR
FINISHED FLOOR
1" MAX
THREADED ROD TO STRCUTURE ABOVE AT EACH PILASTER
TREADED ROD. 1 AT END PILASTER
STEEL COLUMN FLOOR TO STRUCTURE ABOVE. SEE PLAN.
4' -1
0" M
IN
1'
-0 " M
AX
9' -0
" M
AX
FACE OF FINIHSED PARTITION
6"x2"x1/4" HSS WELDED
TO BOTTOM PLATE W/ 3/16" WELD
12"x3 5/8"x1/4" STEEL PLATE
TOP & BOTTOM. FASTEN TOP
PLATE TO STRUCT ABOVE W/
5/8" DIA EXP BOLT TO CONC
1'
0" P
LA
TE
5/8" EXP BOLT
FOR CONCRETE
SEE FLOOR PLAN FOR
PARTITION TYPE
METAL SLEEVE
PLAN VIEW
ELEVATION @
FLOOR STRUCT
ABOVE
2"
6"x2"x1/4" HSS
12"x4"x1/4" STEEL PLATE TOP
2"x2"x1/4" STEEL CLIP
ANGLE EA SIDE
STRUCTURE ABOVE
3/16
(2) 5/8" DIA BOLTS
MC6x6.5
5/8" DIA EXP BOLT TO CONC
1" M
IN
4"
3/8" PLATE EACH SIDE, AT TOP WITH
1/2" DIA THROUGH BOLTS INTO
LONG VERTICAL SLOTS.
4"x4"x1/4"x4" LONG STEEL ANGLE
(2) 5/8" DIA BOLTS OR 3/16"
WELD TO METAL CHANNEL
1/
2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:1
P
M
AE543
INTERIOR PLAN DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"1 PLAN DETAIL - SST BARRIER FLANGE @ WASHER - DISINFECTOR
1 1/2" = 1'-0"2 PLAN DETAIL - SST BARRIER FLANGE @ CART WASH
1 1/2" = 1'-0"3 PLAN DETAIL - PARTITION @ COLUMN M-25
1 1/2" = 1'-0"4 PLAN DETAIL - PARTITION @ COLUMN A1.7 - 30.4
1 1/2" = 1'-0"5 PLAN DETAIL - PARTITION @ COLUMN A1.7 - A1.0
1 1/2" = 1'-0"6 PLAN DETAIL - PARTITION @ COLUMN A2 -OS
1 1/2" = 1'-0"7 PLAN DETAIL - UNDERSIDE OF OPENING AT PREPROCESSOR FOR UTILITIES
3" = 1'-0"8 PLAN DETAIL - TOILET PARTITION SUPPORT
3/4" = 1'-0"9 TOILET PARTITIONS REFERENCE DIAGRAM3" = 1'-0"10 PLAN DETAIL - TOILET PARTITION METAL CHANEL SUPPORT
1'-0" CLEAR
3/4" ADJUSTABLE PLAM SHELVES, SEE
INTERIOR ELEVATIONS FOR QTY.
CEILING AS SCHEDULED
PULL
3/4" PLAM DOOR
1/4" PLAM FACED BACKSE
E
EL
EV
AT
IO
NS
6"
3/4" ADJUSTABLE PLAM
SHELF
3/4" PLAM DOOR
3"
4"
3'- 0"
2'-1"UNO.
SEE ELEVATIONS
BASE AS SCHEDULED
PULL
PLAM DRAWERS WHERE
SHOWN- PROVIDE EDGE
BANDING ON ALL 4 EDGES
CL
R
1/
2"1'-8" CLR
1/4" PLAM FACED BACK
WALL BACKING
S-1 COUNTERTOP W/SIDE AND
BACKSPLASH (SET ON)
1/
2"
GOOSENECK FAUCET AND
STAINLESS STEEL SINK, SEE
PLUMBING DRAWINGS
3"
6"
2'-0"UNO 1"
4"
BASE AS SCHEDULED
PULL
SINK -SEE PLUMBING
3/4" PLAM FIXED PANEL
3/4" PLAM DOOR
1/4" PLAM FACED BACK
S-1 COUNTERTOP W/ 4"
SIDE AND BACKSPLASH
(SET ON)WALL BACKING
3'- 0"
EQ
DRAWER UNITS
FILE UNIT
EQ
3"
4"
BASE AS SCHEDULED
PLAM DRAWERS WHERE
SHOWN- PROVIDE EDGE
BANDING ON ALL 4 EDGES
WALL BACKING
3'-
0"
EASED EDGE
2'-1"
S-1 COUNTERTOP W/SIDE
AND BACKSPLASH (SET ON)
1'- 3"
1/
2" 3"
2'-0"UNO 1"
4"
BASE AS SCHEDULED
3/4" PLAM DOOR - PULL
OUT
1/4" PLAM FACED BACK
S-1 COUNTERTOP W/ 4"
SIDE AND BACKSPLASH
(SET ON)WALL BACKING
3'- 0"
TRASH BIN
FULL EXTENSION RAIL
FOR TRASH BIN
1'-0" CLEAR
3/4" ADJUSTABLE PLAM SHELVES, SEE
INTERIOR ELEVATIONS FOR QTY.
CEILING AS SCHEDULED
PULL
SE
E
EL
EV
AT
IO
NS
STAINLESS STEEL CABINET
AE550
14 GA GALV SHEET METAL
BACKER FOR WATERPROOF
MEMBRANE
SEE FLOOR PLAN AND PARTITION TYPES
FOR PARTITION CONSTRUCTION
BUILDING WRAP ON STUDS-OVERLAP ONTO
SHOWER PAN MEMBRANE
WATERPROOF MEMBRANE
COORDINATE FLOOR SLAB
RECESS WITH STRUCTURAL
CERAMIC TILE
1/2" TILE BACKER BOARD IN LIEU OF 5/8" GYP BD THIS SIDE OF PARTITION
SHOWER PAN MEMBRANE
DRAIN WEEP HOLE AND
CRUSHED TILE OR
STONE
SEE FINISH PLAN FOR
FLOOR FINISH
SLOPE TO DRAIN
1:20 MAX-TYP
SLOPE TO DRAIN
1:20 MAX-TYP
6" 1"
WATERPROOF LIQUID
MEMBRANE
COMPOSITE FLOOR SLAB -
SEE STRUCTURAL
EXISTING WALL
SPS INTERSTITIAL LEVEL
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL. CONTINUOUS
EPOXY FLOOR FINISH EXTEND UP CURB -
SEE PLANS
CONCRETE CURB WITH 1" RADIUS AND
SLOPED TOP - SEE PLAN
4"
113' - 0"
FILL GAP WITH MINERAL WOOL
INSULATION
STEEL BEAM -SEE
STRUCTURAL
SPRAY APPLIED
FIREPROOFING
SB
XN7
J4cs
ALIGN
REMOVED WINDOW SYSTEM
SHOWN DASHED
5/8" GYP BD ON 3 5/8" MEAL
STUDS
3 5/8" METAL STUDS TO
STRUCTURE ABOVE
EXISTING WALL
CONSTRUCTION
H
5/8"
EXISTING LIGHT FIXTURE
AND CEILING
PARTITION OPENING
90 1/2" AFF (VERIFY WITH EQUIP MFG)
STEAM STERILIZER (S0442). OWNER PROVIDED CONTRACTOR INSTALLED
MANUFACTURER TRIM KIT
SEALANT BEAD BETWEEN PARTITION AND
MANUFACTURER TRIM. SEAL AIR TIGHT
SEALANT AROUND PARTITION AND
MANUFACTURER TRIM. SEAL AIR TIGHT
PROVIDE PARTITION TYPE 'B3" WHERE
POSSIBLE AT REMOVED EXTERIOR WALL/
OPENING FOR STEAM STERILIZER
1'-0 3/4"
PLAN DETAIL SIM
AUTOMATED PASS WINDOW (S1905). SEE ELEC
FOR ADDITIONAL INFORMATION
SEALANT BOTH SIDES
SEE PLAN FOR PARTITION TYPE
MECHANICAL/ ELEC COMPARTMENT
SHELF AND BRACKETS BY WINDOW SUPPLIER.
SEALANT BOTH SIDES
DECONTAMINATION
WORK AREA
H21
CLEAN WORKROOM,
ASSEMBLY
H15
SEE MFG FOR AREAS OF WALL
REINFORCEMENT
1"
1"
SE
E
EL
EV
AT
IO
NS
FA
SC
IA
HE
IG
HT
FILLER CUT TO FIT TO MATCH
CABINET FACE
GYPSUM BOARD
CEILING AS SCHEDULED
SIM
1"
3/
4"
SCRIBE AS REQUIRED AND
SEAL
CEILING AS SCHEDULED
FASCIA MATERIAL
TO MATCH
CABINET FACE
.00
8" 4"
1/ 2"
M
IN
1"
3"
2X4 WD BLOCKING, USE PRESSURE
TREATED AT SLABS ON GRADE. LOCATE
BLOCKING AT FRONT AND OPEN ENDS,
OR TO BLOCKING AT 4'-0" ON-CENTER.
COUNTERSUNK #10X3" WOOD
SCREWS @ 16" ON-CENTER 4"
FROM ENDS
SHIM BY CABINET INSTALLER
COUNTERSUNK #10x1.5" WOOD
SCREWS @ 16" ON-CENTER, 2 PER
BLOCKING MIN. AND 4" FROM END TYP
(OMIT IF CABINET HAS INTEGRAL
BASE)
BLOCKING AT ENDS OR
INTERMEDIATE AT 48"
ON-CENTER MAX
FASTNER PER
SPECIFICATIONS
BASE CABINET ANCHORAGEFLOOR CABINET TALLER THAN 3'-0"
UPPER CABINET
BACKING PLATE AT
BOTTOM
#12 TEK SCREWS @ 12" ON-
CENTER, AND WITHIN 3"
FROM ENDS, TYP TOP &
BOTTOM
TRACK BACKING AT TOP
BASE CABINET
SEE BASE CABINET ANCHORAGE
DETAIL "D".
AT CONTRACTORS OPTION;
BACKING PLATE, WITH #12 TEK
SCREWS @ 12" ON-CENTER MAY BE
SUBSTITUTED FOR FLOOR CABINET
CONNECTION
BACKING PLATE
#12 TEK SCREWS @ 12" O.C.
#8 OR #10 SCREW @ 16" ON-CENTER WITH
MIN 5/8" PENETRATION FRONT & BACK
TYP TOP & BOTTOM
SEE BASE CABINET
ANCHORAGE DETAIL "D".
#12 TEK SCREWS @ 12"
ON-CENTER, AND WITHIN
3" FROM ENDS
TRACK BACKING
AT TOP
A
C D
B
7' -2
" M
AX
. AT CONTRACTORS OPTION;
BACKING PLATE, WITH #12
TEK SCREWS @ 12" ON-
CENTER MAY BE
SUBSTITUTED FOR FLOOR
CABINET CONNECTION
3/4" MIN PLYWOODBACKING UNDER ENTIRE COUTNER TOP.
2" RADIUS AT ALL OUTSIDE CORNERS
SOLID SURFACE COUNTERTOP SUPPORT BLOCK
/ BACKING AT CORNER PER MANUFACTURES
RECOMMENDATIONS
SOLID SURFACE BUILT UP EDGE BELOW.
FACE OF CASEWORK BELOW.
FACE OF CASEWORK BELOW.
1"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:1
P
M
AE550
INTERIOR SECTION DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1" = 1'-0"1 SECTION - WALL CABINET WITH DOOR
1" = 1'-0"2 SECTION - BASE CABINET DRAWER & DOOR
1" = 1'-0"3 SECTION - BASE CABINET WITH SINK
1" = 1'-0"5 SECTION - BASE CABINET 3 DRAWER W/ 2 EQ
1" = 1'-0"4 SECTION - BASE CABINET TRASH
1" = 1'-0"6 SECTION - STAINLESS STEEL WALL CABINET WITH DOOR
3" = 1'-0"10 SECTION DETAIL INTERIOR - WATERPROOFING AT TOILET ROOM FLOOR
1 1/2" = 1'-0"11 SECTION DETAIL - EXPANSION JOINT AT MECH ROOM (TYP)
1 1/2" = 1'-0"13 SECTION DETAIL - OPENING AT SURGERY / OR CORRIDOR
1 1/2" = 1'-0"14 SECTION DETAIL - OPENING AT STEAM STERALIZER (TYP)
1 1/2" = 1'-0"15 SECTION DETAIL - AUTOMATED PASS WINDOW
3/4" = 1'-0"7 CASEWORK / LOCKERS AT GYP BD SOFFIT
3/4" = 1'-0"8 CASEWORK UPPER WITH SLOPED TOP
3/4" = 1'-0"9 CASEWORK ANCHORAGE
3" = 1'-0"12 PLAN DETAIL - COUNTERTOP OUTSIDE CORNER (TYP)
COMPOSITE FLOOR SLAB -
SEE STRUCTURAL
EXISTING WALL
SPS INTERSTITIAL LEVEL
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL. CONTINUOUS
EPOXY FLOOR FINISH EXTEND UP CURB -
SEE PLANS
CONCRETE CURB WITH 1" RADIUS AND
SLOPED TOP - SEE PLAN
4"
1511' - 11 3/4"
FILL GAP WITH MINERAL WOOL
INSULATION
6"x4"x1/2" HSS -SEE STRUCTURAL
FIRST LEVEL
111' - 11"
SPRAY APPLIED FIREPROOFING
EXISTING WALL / FLOOR
CONSTRUCTION.
STEEL BEAM - SEE STRUCTURAL
20"x4"x1/2" HSS - SEE STRUCTURAL
REMOVE BRICK AS REQUIRED FOR
HSS INSTALLATION. GROUT SOLID
ABOVE HSS AS REQUIRED
3 5/8" METAL STUDS TO STRUCTURE
ABOVE
5/8" GYP BD ON 3 5/8" METAL STUDS
SE
E
RC
P
CART WASHER (S3185)PROVIDE CONTINUOUS 18GA SST FLANGE.
MITER AT CORNERS AND PROVIDE SEALANT
6"
CONTINUOUS SEALANT BEAD
BEHIND SST FLANGE
5/8" GYP BD ON 3 5/8" METAL
STUDS TO STRUCTURE ABOVE
5/8" GYP BD ON 3 5/8" METAL
STUDS
SEALANT
SPRAY APPLIED FIREPROOFING
SST FASTENERS AS REQUIRED
5 1/4"
1'-0"
D
E
COMPOSITE SLAB - SEE
STRUCTURAL
SPS INTERSTITIAL LEVEL
EPOXY FLOOR FINISH EXTEND UP CURB -
SEE PLANS
CONCRETE CURB WITH 1" RADIUS AND
SLOPED TOP - SEE PLAN
113' - 0"
EXISTING STAIR LANDING
STEEL BEAM & DIAG BRACE - SEE
STRUCTURAL
WALL CONSTRUCTION
J4c
PROVIDE UL RATED 2 HOUR
HORIZONTAL SHAFTWALL
ASSEMBLY
J4c
1'-0"
5 1/2"x3"x5/16" LLV, BENT
PLATE - SEE STRUCTURAL
8 3/4"
TOP OF OPENING
110' - 4"
6'x6"x1/2" STEEL ANGLE -SEE STRUCTURAL
SEE STRUCTURAL
2"
STEEL WIDE FLANGE
BEAM - SEE STRUCTURAL
6"
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL. CONTINUOUS
E
COMPOSITE SLAB - SEE
STRUCTURAL
SPS INTERSTITIAL LEVEL
EPOXY FLOOR FINISH EXTEND UP CURB -
SEE PLANS
CONCRETE CURB WITH 1" RADIUS AND
SLOPED TOP - SEE PLAN
113' - 0"
STEEL BEAM & DIAG BRACE - SEE
STRUCTURAL
WALL CONSTRUCTION
J4c
PROVIDE UL RATED 2 HOUR
HORIZONTAL SHAFTWALL
ASSEMBLY
J4c
1'-0"
J2c
EXISTING STAIR LANDING
5 1/2"x3"x5/16" LLV, BENT
PLATE - SEE STRUCTURAL
8 3/4"
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL. CONTINUOUS
DIAGONAL HSS BRACE FRAME BEYOND -
SEE STRUCTURAL
F
COMPOSITE SLAB - SEE
STRUCTURAL
SPS INTERSTITIAL LEVEL
113' - 0"
STEEL BEAM - SEE STRUCTURAL
WALL CONSTRUCTION
J4c
PROVIDE UL RATED 2 HOUR
HORIZONTAL SHAFTWALL
ASSEMBLY
1'-0"
5 1/2"x3"x5/16" LLV, BENT
PLATE - SEE STRUCTURAL
J2c
EXISTING STAIR LANDING
COMPRESSIBLE INSULATION
3/4" PLYWOOD
2X WOOD BLOCKING
KERF CUT INTO EXISTING BRICK
SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
PREFINISHED BREAK METAL FLASHING
ELASTOMERIC SHEETING.. EXTEND UP FACE OF BRICK
PREFINISHED MANUFACTURED
EXPANSION JOINT COVER
MEMBRANE ROOF EXTEND UP
FACE OF PLYWOOD AND OVER
WOOD BLOCKING.
ELASTOMERIC SHEETING. EXTEND OVER WOOD
BLOCKING AND DOWN FACE OF PLYWOOD
PREFINISHED BREAK METAL REGLET
TAPERED ROOF INSULATION -
SEE ROOF PLAN
CONTINUOUS SHEET VAPOR
RETARDER. EXTEND UP FACE OF FIRE
RATED PLYWOOD AND LAP UNDER CAP
FLASHING
NOTES APPLY/3 AE530
1/2" COVER BOARD
COMPOSITE FLOOR SLAB -
SEE STRUCTURAL
SPS INTERSTITIAL LEVEL
EPOXY FLOOR FINISH EXTEND UP CURB -
SEE PLANS
CONCRETE CURB WITH 1" RADIUS AND
SLOPED TOP - SEE MECHANICAL FOR
LOCATION
4"
113' - 0"
CONCRETE CURB - SEE STRUCTURAL FOR
ADDITIONAL INFORMAION
VERIFY WITH MECH / TELECOM / ELEC CONTRACTOR.
SIZE PAD MIN 6" BEYOND FOOTPRINT OF EQUIPMENT
3"
4"
1/ 2"
1/2"
CONC HOUSEKEEPING PAD:
FOR SCOPE OF WORK, REFER TO
MECHANICAL AND ELECTRICAL
DRAWINGS AND COORDINATE WITH
THESE CONTRACTORS
TOP OF EXISTING
CONCRETE FLOOR
SLAB
SEE STRUCTURAL FOR
REINFORCEMENT
DOWEL BARS. SEE
STRUCTURAL
1/
2"
EPOXY FLOOR
FINISH EXTEND UP
SIDE OF PAD
SB
REMOVED WINDOW SYSTEM
SHOWN DASHED
5/8" GYP BD ON 1/2" GYP BD.
EXISTING WALL
CONSTRUCTION
EXISTING LIGHT FIXTURE
AND CEILING
EXISTING PARTITION/ SOFFIT
CONSTRUCTION. FIELD VERIFY
CONSTRUCTION AND MATCH
AS REQUIRED
4" METAL STUD
5/8" GYP BD
WOOD BLOCKING AS
REQUIRED
VIRTUAL WINDOW TRIM BY
VIRTUAL WINDOW MFG
VIRTUAL WINDOW SYSTEM
WITH BACK PAN
VIRTUAL WINDOW TRIM BY
VIRTUAL WINDOW MFG
WOOD BLOCKING AS
REQUIRED
EXISTING WALL
CONSTRUCTION
METAL RUNNER CHANEL
PATCH GYP BD TO MATCH
EXISTING. SEE PLANS FOR
ADDITIONAL INFORMATION
REMOVED WINDOW SYSTEM
SHOWN DASHED
EXISTING WALL
CONSTRUCTION
WOOD BLOCKING AS
REQUIRED
VIRTUAL WINDOW TRIM BY
VIRTUAL WINDOW MFG
VIRTUAL WINDOW SYSTEM
WITH BACK PAN
VIRTUAL WINDOW TRIM BY
VIRTUAL WINDOW MFG
WOOD BLOCKING AS
REQUIRED
EXISTING WALL
CONSTRUCTION
PATCH TO MATCH EXISTING.
SEE PLANS FOR ADDITIONAL
INFORMATION
B6
FILL CAVITY BEHIND VIRTUAL
WINDOW WITH BATT
INSULATION
METAL RUNNER TRACK AS
REQUIRED
PATCH TO MATCH EXISTING.
SEE PLANS FOR ADDITIONAL
INFORMATION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:2
P
M
AE551
INTERIOR SECTION DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"1 SECTION DETAIL - STEEL TUBE AND SOFFIT AT AUTOMATIC CART WASHER - H20B 1 1/2" = 1'-0"2 SECTION DETAIL - RATEED WALL AND SOFFIT AT EXISTING STAIR TOWER & BRACED FRAME
1 1/2" = 1'-0"3 SECTION DETAIL - RATEED SOFFIT AT STEEL BEAM / BRACED FRAME
1 1/2" = 1'-0"4 SECTION DETAIL - RATEED SOFFIT AT STEEL BEAM & ROOF EXPANSION JOINT
1 1/2" = 1'-0"5 SECTION DETAIL - CONCRETE EQUIPMENT CURB
3" = 1'-0"6 SECTION DETAIL - CONCRETE HOUSEKEEPING PAD
1 1/2" = 1'-0"7 SECTION DETAIL - HEAD /SILL AT VIRTUAL WINDOW -SURGERY / OR CORRIDOR C43 1 1/2" = 1'-0"8 SECTION DETAIL - HEAD /SILL AT VIRTUAL WINDOW - FIRST LEVEL (TYP)
EXISTING SOFFIT
CONSTRUCTION.
J4cs
PATCH GYP BD AND PAINT
UNDERSIDE OF SOFFIT
WOOD BLOCKING AS
REQUIRED
VIRTUAL WINDOW TRIM BY
VIRTUAL WINDOW MFG
VIRTUAL WINDOW SYSTEM
WITH BACK PAN
VIRTUAL WINDOW TRIM BY
VIRTUAL WINDOW MFG
WOOD BLOCKING AS
REQUIRED
7'-2"
TO VIRTUAL WINDOW
EXISTING WALL
CONSTRUCTION - SEE
STRUCTRUAL
J2c
SEE ELEVATIONS
BO VIRTUAL WINDOW
EXISTING WALL
CONSTRUCTION
WOOD BLOCKING AS
REQUIRED
VIRTUAL WINDOW TRIM BY
VIRTUAL WINDOW MFG
VIRTUAL WINDOW SYSTEM
WITH BACK PAN
VIRTUAL WINDOW TRIM BY
VIRTUAL WINDOW MFG
WOOD BLOCKING AS
REQUIRED
PATCH TO MATCH EXISTING.
SEE PLANS FOR ADDITIONAL
INFORMATION. PAINT
METAL RUNNER TRACK AS
REQUIRED
COMPOSITE FLOOR SLAB -
SEE STRUCTURAL
EXISTING WALL
SPS INTERSTITIAL LEVEL
UL RATED 2 HOUR EXPANSION JOINT
MATERIAL. CONTINUOUS
EPOXY FLOOR FINISH EXTEND UP CURB -
SEE PLANS
CONCRETE CURB WITH 1" RADIUS AND
SLOPED TOP - SEE PLAN
1511' - 11 3/4"
FILL GAP WITH MINERAL WOOL
INSULATION
FIRST LEVEL
111' - 11"
EXISTING WALL / FLOOR
CONSTRUCTION.
STEEL BEAM - SEE STRUCTURAL
20"x4"x1/2" HSS - SEE STRUCTURAL
REMOVE BRICK AS REQUIRED FOR
HSS INSTALLATION. GROUT SOLID
ABOVE HSS AS REQUIRED
EXISTING PARTITION. FIELD VERIFY
LOCATION
SPRAY APPLIED FIREPROOFING
1'-0"
D
J2cXP3
HSS DIAGONAL BRACE FRAME - SEE
STRUCTURAL
L-SHAPED METAL SUPPORT BRACKETS AND
CONCEALED BACKING BY CASKWORK SUPPLIER.
FINISH: HEAVY DUTY EPOXY COATED, PAINT TO
MATCH WALL. ATTACHED TO CONCEALED
BACKING. PROVIDE PLAM FASCIA COVER AT
EXPOSED ENDS.
1.25"X1.25" SOLID SQ STL BAR
WITH 1.25"X3" STL PLATE,
WELDED
4 #12 SCREWS, TOP AND
BOTTOM
GRIND SMOOTH
GUSSET
COUNTERTOP TYPE - REFER TO ELEVATION FOR
MORE INFORMATION
MAX LOAD PER
BRACKET: 300 LB
12 GA STUD
(TYP)
B METAL SUPPORT BRACKET DETAILA METAL BRACKET
1'- 3"
4"
3"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:2
P
M
AE552
INTERIOR SECTION DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"1 SECTION DETAIL - HEAD /SILL AT VIRTUAL WINDOW -ELEVATOR LOBBY G79-5
1 1/2" = 1'-0"2 SECTION DETAIL - HEAD /SILL AT VIRTUAL WINDOW -DR WORK ROOM D18
1 1/2" = 1'-0"3 SECTION DETAIL - STEEL TUBE AND WINDOW INFILL -DR WORK ROOM D18
1" = 1'-0"4 COUNTERTOP SUPPORT BRACKETS
3 5/8" METAL STUDS AT 16"
0N CENTER SECURE TO
STRUCTURE ABOVE
DIAGONAL STUD BRACE BACK
TO STRUCTURE AT 4'-0" ON
CENTER
HANGER WIRE
CEILING AS SCHEDULED
STUD RUNNER CHANNEL
5/8" GYP BD
6" M
IN
4 7/8"
SE
E
RC
P
SE
E
RC
P
3 5/8" METAL STUDS AT 24" OC
TO STRUCTURE ABOVE
5/8" GYP BD CEILING AS
SCHEDULED
3 5/8" DIAGONAL STUD BRACE BACK
TO STRUCTURE AT 4'-0" 0N CENTER
SE
E
RC
P
1'- 0"
5/8" GYP BD
CEILING AS
SCHEDULED
SE
E
RC
P
6" M
IN
5/8" GYP BD
3 5/8" METAL STUDS TO
STRUCTURE ABOVE
5/8" GYP BD ON 3 5/8"
METAL STUDS AT 24" OC
3 5/8" DIAGONAL STUD BRACE BACK
TO STRUCTURE AT 4'-0" 0N CENTER
SE
E
RC
P
TO
S
TR
UC
TU
RE
A
BO
VE
EXISTING
STRUCTURE
5/8" GYP BD
CEILING AS
SCHEDULED
SE
E
RC
P
6" M
IN
3 5/8" METAL STUDS TO
STRUCTURE ABOVE
5/8" GYP BD ON 3 5/8"
METAL STUDS AT 24" OC
3 5/8" DIAGONAL STUD BRACE BACK
TO STRUCTURE AT 4'-0" 0N CENTER
SE
E
RC
P
TO
S
TR
UC
TU
RE
A
BO
VE
EXISTING
STRUCTURE
5/8" GYP BD
CEILING AS
SCHEDULED
SE
E
RC
P
MC6x6.5 CONTINIOUS. SEE ELEVATIONS
2"x2"x1/4" STEEL ANGLE
2"x2"x1/4"x2" LONG (MIN) BENT PLATE
TOILET PARTITION PILASTER
WITH CEILING TRIM
ACT CEILING
1/2" THREADED ROD (2)
RODS PER PILASTER MIN.
(1) ROD AT END PILASTER
BEVELED WASHER
EXISTING STRUCTURE. FIELD VERIY RIB
LOCATIONS AND SIZES AS REQUIRED.
SELANT AT ALL THREADED ROD
PENETRATIONS
5/8" DIA THREADED ROD AT EACH TOILET
PARTITION PILASTER. ANCHOR TO
STRUCTURE ABOVE
PROVIDE DIAGONAL SWAY BRACE
PARALLEL TO MC6 AT EACH END OF
CHANNEL, IF CHANNEL IS NOT CONNECTED
TO TUBE STEEL. SEE DIAGRAM .
5/8" DIA EXPANSION BOLT
TO STRUCTURE ABOVE
5/8" DIA BOLT
(TYP)
DIAGONAL SWAY BRACE AT
EACH THREADED ROD
METAL STUDS EACH SIDE OF MC
M
AX
1/
2"
8" MAX
1"x1" MIN CONTINUOUS WALL
ANGLE. ATTACH AT EACH
STUD
ATTACH GYP TO ANGLE
12" OC MAX 5/8" GYP BD CEILING. PAINT
AS SCHEDULED.
1 1/2" CHANNEL. 4'0-" OC MAX. ALTERNATE
OPEN FACE OF CHANNEL AT EVERY OTHER
CHANNEL.
7/8" HAT CHANNEL. 24" OC MAX
METAL FURRING CHANEL CLIP OR WIRE TIE
TIE WIRE TO HANGER CLIPS ABOVE.
FACE OF PARTITION.
GYP BD JOINT
REINFORCEMENT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri \O n e D ri v e
A N
D E
R S
O N
E N
G
IN
E E
R
IN
G O
F M
N \D o c u m e n ts
\1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:0
:2
P
M
AE560
CEILING DETAILS CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1 1/2" = 1'-0"1 SECTION DETAIL - GYP BD BULKHEAD
1 1/2" = 1'-0"3 SECTION DETAIL - GYP BD TO GYP BD CEILING TRANSITION
1 1/2" = 1'-0"2 SECTION DETAIL - GYP BD RETURN
1 1/2" = 1'-0"5 SECTION DETAIL - GYP BD CEILING TO GYP BD CEILIGNG
1 1/2" = 1'-0"4 SECTION DETAIL - CEILING MOUNTED TOILET PARTITIONS
1 1/2" = 1'-0"6 SECTION DETAIL - SYSPENDED GYP BD CEILING
NO SUBSCRIPT
EXTEND ENTIRE
PARTITION TO
UNDERSIDE OF
STRUCTURE
FLOOR
CEILING
BOTTOM
OF FLOOR
OR DECK
(D) SUBSCRIPT
EXTEND STUDS TO
DECK, EXTEND
GYPSUM BOARD TO
6" ABOVE HIGHEST
ADJACENT CEILING
6"
(C) SUBSCRIPT
EXTEND ENTIRE
PARTITION TO 6"
ABOVE HIGHEST
ADJACENT
CEILING
6"
(U) SUBSCRIPT
EXTEND ENTIRE
PARTITION TO
UNDERSIDE OF
CEILING
(X'-X") SUBSCRIPT
INDICATES
FINISHED
PARTITION HEIGHT
IN
S
UB
SC
RI
PT
HE
IG
HT
A
S
IN
DI
CA
TE
D
GENERAL NOTES:
1. FOR PARTITIONS WITH UNEQUAL LAYERS OF GYPSUM BOARD ON EACH SIDE, THE SIDE OF THE PARTITION
WITH THE TAG INDICATES WHERE THE EXTRA LAYER(S) OF GYPSUM BOARD ARE TO BE INSTALLED. REFER
TO PARTITION TYPES FOR MORE INFORMATION
2. DIMENSIONS TO METAL STUD PARTITIONS ARE MEASURED TO FINISH FACE UNLESS NOTED OTHERWISE
3. AT INFILL WITHIN OR EXTENSIONS ONTO EXISTING PARTITIONS, THE PARTITION TAG NOTED IS FOR INTENT
ONLY. FINISHED PARTITION FACES ARE TO ALIGN WITH ADJACENT EXISTING PARTITION FACES
4. SUBSCRIPTS MAY BE USED WITH ANY PARTITION TYPE
XN2 XN3 XP2 XP3
(1 )…