This document is an architectural floor plan (Drawing AE111) for a new Sterile Processing Services (SPS) addition at the Sioux Falls VA Health Care System. The detailed floor plan shows an interstitial/first level floor plan with multiple room spaces including mechanical areas, corridors, procedure rooms, toilets, waiting areas, reception, and various technical spaces. The plan includes detailed grid lines, room dimensions, and specific construction notes such as requirements for concrete curbs, equipment pads, fire retardant plywood installations, and patch work for existing wall and floor surfaces.
The drawing is part of a construction project (Project #438-460) for the Department of Veterans Affairs, specifically for the Royal C. Johnson Veteran's Memorial Hospital in Sioux Falls, South Dakota. The project involves approximately 8,500 square feet of new construction and 2,300 square feet of renovation, with an interstitial/mechanical space matching the SPS space's footprint. The document is dated 02/14/2025, with subsequent addendums on 03/28/2025 and 05/20/2025, and is prepared by IMEG Consultant and Anderson Architect, with the plan marked as "Bid Documents" and noted as "Fully Sprinklered".
View the file
Other files
Show 40 more
Latest 50 of 61 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AE201
AE201
AE301
L
M
N
O
SB
S2 X21 G.99
21 22 23 24 6
1S
0S
A2.1
5.3
J.99
30.6
30.5
A1
G.2
C
A3.5
AE301
AE301
AE301
AE302
AE314
AE312
AE311
AE313
AE313
AE313
AE301
AE322
AE322
AE302
121A
STAIR #5
TOILET
WORK
ROOM
PROCEDURE
ROOM
TOILET
CORRIDOR
MECH
SOILED
CLEAN
M.H.
ELEC
WORK
ROOM
WAITING
RECEPTION
129A
HAC
STAIR #4 131
131A
120A
126B
STAIR
TELECOM
111A
MECHANICAL
G
H
INTERSTITIAL
SPACE
AE20
AE20
A3
AE312
2 3 4 4.9
B
H
G
CORRIDOR
AE321
AE322
AE501
AE502
AE502
AE503
AE503
AE212
D
E
F
1.7 1.8 4.3 5 25 7 27
C.3
A1.1
A1.7
A2.9
A2.10
30.4
30.1
AE201
AE301
FL3
FL3
FL3
FL10
FL6
FL6
FL6
FL6
FL6
FL6
FL6
FL6
SEE ROOF PLAN FOR WORK IN THIS AREA
FL10
AE541
AE542
AE542
AE542
AE542
AE320
FL1
FL1 FL1
FL1
FL1
FL1
FL1
FL1
FL1
AE551
TYP
NOTE:
• SEE EQUIPMENT PLANS FOR ADDITIONAL
INFORMATION
• GROUND LEVEL FINISHED FLOOR ELEVATION (EL:
100'-0") TO ALIGN WITH EXISTING GROUND LEVEL.
SEE CIVIL FOR ADDITIONAL INFORMATION.
LIMITS OF CONSTRUCTION
LI
M
IT
S
O F
C O
N S
T R
U C
T
IO
N
LIM
ITS OF CONSTRUCTION
'-5
/4
9'
-6
'-1
1/
2" 1'
-0
'-2
1'
-6
8' -8
1'
-6
'-1
1/
2"
'-1
1/ 2"
16'-3 3/4" 2'-10" 3'-0" 5'-0" 15'-10 1/2" 4'-6" 15'-6" 4'-6" 3'-7" 11'-11" 2'-9" 1'-9" 4'-8" 9'-4" 1'-6" 11'-6" 8'-6"
3'-8 1/4"
1'- 4"
3'- 4"
7'-
3/ 4"
3'-
1/ 4"
3'- 0"
2'- 4"
STOOP SEE CIVIL & STRUCTURAL
B6
AE530
AE530
AE530
B6
AE551
AE551
AE551
TYP
TYP
TYP
B6 B6
TYP
FL12FL12
FL12
FL12
FL12
FL12
A1.0
14'-2 1/4"
10 1/2"
3'-2"
16'-3 5/16"
1'-4"
1'-10"
C52
CORRIDOR
FL15
FL15
FL15
FL15
STAIR #10
FEC-2
FEC-2
FEC-2 D18D
MECHANICAL
D18E
TOILET
D18F
LOCKER
D18G
EXAM
D18H
EXAM
D18I
TOILET
D18J
EXAM
126A
MECHANICAL
FL16
SEE MECH FOR
DUCTWORK
PENETRATIONS THOUGH
WALL IN THIS AREA
B6
FL17
GENERAL NOTES
1. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS AND LIMITS OF
CONSTRUCTION WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT.
INCIDENTAL WORK MAY BE NECESSARY IN AREAS NOT SHOWN ON ARCHITECTURAL
DRAWINGS DUE TO CHANGES AFFECTING ELECTRICAL, MECHANICAL, PLUMBING AND
OTHER SYSTEMS. THIS INCIDENTAL WORK SHALL BE PART OF THIS CONTRACT.
INSPECT THESE AREAS TO ASCERTAIN WORK REQUIRED AND PREFORM THE WORK
IN ACCORDANCE OF CONTRACT REQUIREMENTS.
2. PROVIDE FIREPROOFING TO THE RATING REQUIRED AS INDICATED IN THE LIFE
SAFETY PLAN, CODE SUMMARY AND PER NFPA ON STRUCTURAL STEEL ELEMENTS.
3. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
4. PATCH OPENINGS CUT THOUGH RATED CONSTRUCTION WITH MATERIALS
COMPATIBLE WITH EXISTING ASSEMBLY TO RESTORE INTEGRITY OF THE RATING.
RESTORE FINISHES OF DISTURBED AREAS TO LIKE NEW CONDITION.
5. GENERAL CONTRACTOR TO CHECK MECHANICAL DRAWINGS FOR EXISTING PIPES
AND DUCTS FURRED IN WALLS. VERIFY SIZE AND LOCATION WITH MECHANICAL
CONTRACTOR PRIOR TO PROCEEDING WITH REMODELING.
6. RESTORE EXISTING FIREPROOFING TO RATINGS INDICATED ON LIFE SAFETY PLANS
WITH MATERIALS TO MATCH EXISTING.
7. AT LOCATIONS WHERE EXISTING FIRESTOPPING IS REQUIRED TO BE ALTERED,
REMOVE EXISTING FIRESTOPPING SYSTEM IN ITS ENTIERTY AND REPLACE FIRE
STOPPING SYSTEM WITH NEW FIRESTOPPING MATERIALS THAT MEET THE RATING
REQUIREMENTS OF THE PENETRATION.
8. DIMENSIONS OF EQUIPMENT ARE THOSE OF THE BASIS-OF-DESIGN EQUIPMENT.
VERIFY DIMENSIONS OF ACTUAL EQUIPMENT BEING PROVIDED TO COORDINATE
SPACE REQUIREMENTS.
9. VERFITY DIMENSIONS OF MECHANIOCAL OR ELECTRICAL EQUIPMENT PRIOR TO
FABIRICATING SUPPORTS FOR THE EQUIPMENT.
10. PATCH AREAS DISTURBED OR MODIFIED BY THIS WORK WITH MATERIALS TO
MATCH EXISTING ADJACENT SRUFACES OR SCHEDULED FINISHES AND TO A LIKE
NEW CONDITION.
11. PROVIDE ACCESS PANELS WHERE INDICATED ON DRAWINGS AND WHERE
DESCRIBED IN SPEFICATIONS SECTION 08 31 13. COORDINATE LOCATIONS AND SIZES
REQUIRED (24" X 24" MINIMUM) WITH MECHANICAL, PLUMBING, ELECTRICAL AND
TECHNOLOGY SUBCONTRACTORS.
12. ABREVIATIONS AND SYMBOLS OF ARCHITECTURAL, STRUCTURAL, MECHANICAL,
AND ELECTRICAL MAY VARY BY DISCIPLINE. SEE RESPECTIVE DISIPLINE SECTIONS
AND/OR DRAWINGS FOR DEFINITIONS.
13. AT MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, PROVIDE 3/4" FIRE
RETARDANT TREATED (FRT) PLYWOODON SURFACE OF SCHEDULED PARTITION FOR
SURFACE MOUNTED FIXTURES AND EQUIPMENT, UNLESS NOTED OTHERWISE. DO
NOT PAINT OVER FRT LABEL.
14. EVALUATE INTEGRITY OF EXISTING LIFE SAFETY RATED PARTITION ASSEMBLIES
INDICATED BY SYMBOLS ON THE LIFE SAFETY PLAN(S) WITHIN THE PROJECT SCOPE
INCLUDING PENETRATIONS THOUGH ASSEMBLY AND BASE AND HEAD OF ASSEMBLY.
WHERE GAPS OR DEFFICIES ARE FOUND, RESTORE INTEGRITY OF EXISTING
ASSEMBLIES WITH MATERIAL NECESSARY TO MEET REQUIRED REATING OF THE
ASSEMBLIES.
FLOOR PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL
EXISTING DOOR
AND FRAME TO
REMAIN
DOOR
INTERIOR
BORROWED LIGHT
101B
101A
8'-0"
DIMENSION LINE,
NOMINAL
8'-0" EXTENDED
DIMENSION LINE,
NOMINAL
AE2111A
INTERIOR
ELEVATION
INDICATOR TAG
2B
AE2O1
EXTERIOR
ELEVATION
INDICATOR TAG
1A
203 EQUIPMENT TAG
100 FLOOR SPOT
ELEVATIONWALL TAG
OFFICE
ROOM NAME AND
NUMBER AE501
1A
DETAIL REFERENCE
TAG
AE2O1
EXTERIOR SECTION
REFERENCE TAG
1A
AE2O1
INTERIOR SECTION
REFERENCE TAG
1A
KEY NOTE
A
GRIDLINE
REVISION TAG
PR01
REVISION CLOUD
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
FP10
B3
FLOOR PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FL1
PATCH PARTITION, WITH MATERIALS TO MATCH EXISTING ADJACENT
SURFACES, AS REQUIRED FROM DEMOLITION. WHERE EXISTING FINISHES
ARE DISTURBED PAINT TO MATCH ADJACENT FINISH, PAINT ENTIRE WALL
OF EXISTING INTERIOR SPACES WHERE PATCHING OCCURS.
FL2
4" H x 4" W CONTINUOUS CONCRETE CURB AT DUCTWORK AND / OR
OPENING IN SLAB. PROVIDE 1" RADIUS AT ROOM SIDE OF CURB.
FL3
4" HIGH CONCRETE PAD FOR EQUIPMENT. COORDINATE SIZE AND
LOCATION WITH MECHANICAL. PAD SHOULD EXTEND MIN 6" ALL SIDES
FROM EDGE OF EQUIPMENT.
FL4
PROVIDE FIRE RETARDANT PLYWOOD 3 SIDES OF ROOM. SEE TYPICAL
ELEVATIONS SHEET AE212
FL5
RATED EXPANSION JOINT SEE DETAIL
FL6
4" H x 4" W CONTINUOUS CONCRETE CURB WITH 1" RADIUS AT ROOM SIDE
AND SLOPED TOP. SEE WALL SECTIONS
FL7
EXISTING HOLLOW METAL DOOR FRAME. PATCH HOLES IN FRAME, PATCH
DOOR LATCH AND HINGE POCKETS WITH STEEL PLATE SAME THICKNESS
AS FRAME, WELD FULLY AND GRIND WELDS SMOOTH. REMOVE EXISTING
RUST AS REQUIRED PATCH IN SAME MANOR AS LATCH AND HINGES. PREP
FRAME FOR PAINT. PANT DOOR FRAME COLOR AS SCHEDULED
FL8
STOOP AND / OR STAIRS -SEE STRUCTURAL AND CIVIL
FL9
PATCH CONCRETE FLOOR AT REMOVED EXTERIOR WALL. SEE SECTIONS
FOR ADDITIONAL INFORMATION
FL10
PROVIDE CONCRETE RAMP AT DOOR.
FL11
INFILL WALL AT REMOVED LOUVER AT PIPE BASEMENT LEVEL. MATCH
EXISTING MATERIALS. SEE STRUCTURAL FOR ADDITIONAL INFORMATION
FL12
LUMINOUS VIRTUAL WINDOW. SEE DETAIL /8 AE212
FL13
MODIFY HANDRAIL AS REQUIRED FOR OPENING AS SCHEDULED.
FL14
1'-0" x 1'-0" SST ACCESS PANEL. COORDINATE LOCATION WITH MECH
FL15
STEEL DIAGONAL FRAMING. SEE STRUCTURAL
FL16
PATCH FINISHES TO MATCH THOSE DISTURBED BY CONSTRUCTION AT
WALL AND CEILING. CONTRACTOR TO PROVIDE LABOR AND MATERIALS.
FL17
PATCH WALL AS REQUIRED FROM O2 CONNECTOR BOX INSTALL. TOOTH IN
BRICK AS REQUIRED. PROVIDE METAL STUDS AS REQUIRED FOR
MOUNTING BOX. PROVIDE SEALANT AT EXTERIOR BRICK AND BOX AND AT
THE INSIDE FACE OF THE EXTERIOR SHEATHING. PATCH INTERIOR FACE
OF WALL TO MATCH ADJACENT SURFACES. SEE MECHANICAL / PLUMBING
DRAWINGS FOR ADDITIONAL INFORMATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Tom Olesak
Date: 02/14/2025
License Number: 18157
2882 106th St, Urbandale, IA 50322
C U s e rs
\g b a rb a ri
\D o c u m e n ts \1
-R
G io v a n n i- B a rb a ri .r v t
/2
/2
:4
:0
P
M
AE111
INTERSTITIAL/FIRST LEVEL FLOOR
PLAN
CONSTRUCT NEW SPS
Sioux Falls, SD.
438-460
02/14/2025 LA GJB16584
1/8" = 1'-0"
INTERSTITIAL/FIRST LEVEL FLOOR PLAN
0 8' 16'4' TRUE
NORTH
PLAN
NORTH
Revisions: Date:
ADDENDUM 1 (AD-1) 03/28/2025
ADDENDUM 3 (AD-3) 05/20/2025
AD-1
AD-1
AD-1
AD-3
AD-3
AD-3
AD-3
AD-3
| Sheets |
| AC101 - GROUND LEVEL REFLECTED CEILING PLAN |
| AD111 - INTERSTITIAL/FIRST LEVEL DEMOLITION PLAN |
| AE111 - INTERSTITIAL/FIRST LEVEL FLOOR PLAN |
| GC111 - FIRST LEVEL INFECTION CONTROL & PHASING PLAN |
File details come from the government source that posted it. Updated .