S06 - Amend 0009 - Att 03 - DWG AC101 - Rvd - SPS - Sioux Falls.pdf

PDF 587 KB Posted

Attached to
Y1DA--VHA Minor - Construction - Project #438-460 - Sterile Processing Services - Royal C Johnson Veteran's Memorial Hospital - VISN 23 - Sioux Falls SD
Solicitation number
36C77624R0115
Issued by

About this file

This document is a Ground Level Reflected Ceiling Plan (drawing AC101) for a new Sterile Processing Services (SPS) construction project at the Sioux Falls VA Health Care System. The detailed architectural drawing shows a comprehensive ceiling plan with multiple rooms and areas, including operating rooms, storage spaces, corridors, locker rooms, decontamination work areas, and specialized zones like scope processing and sterilization areas. The plan includes specific ceiling height annotations (ranging from 8'-0" to 11'-4" AFF - Above Finished Floor), ceiling system symbols, and general notes about ceiling installation, mounted equipment coordination, and construction requirements.

The drawing is part of a VA project (Project Number 16584) dated 02/14/2025, prepared by IMEG consultant and Anderson Architect, with the licensed architect Tom Olesak. The plan is marked as "Bid Documents" and indicates a fully sprinklered facility located in Sioux Falls, South Dakota. The drawing provides technical details for contractors, including reflected ceiling plan symbols, keyed notes about access panels, ceiling replacement, construction barriers, and general installation guidelines for ceiling-mounted equipment and systems.

View the file

Other files

File Type Posted
S06 - Amend 0010 - RFP - 36C77624R0115 - SPS - Sioux Falls_rev.docx DOCX document
S06 - Amend 0010 - RFP - 36C77624R0115 - SPS - Sioux Falls.docx DOCX document
S06 - Amend 0009 - Att 12 - DWG EP111 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 07 - List of DWG Sheets - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 10 - Ele Sch - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 16 - DWG ES401 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 04 - DWG AD111 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 08 - DWG CD101 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 01 - Sign-In Sheet - Ele Site Visit- 05142025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 19 - DWG MV600 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 20 - DWG GI001 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 13 - DWG ES099 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 06 - DWG GC111 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 17 - DWG ES500 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 09 - Add Ele Questions and Responses - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 15 - DWG ES400 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 11 - DWG EP101 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - RFP - 36C77624R0115 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 18 - DWG ES501 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 02 - Narrative to KTRs - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 14 - DWG ES100 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0009 - Att 05 - DWG AE111 - Rvd - SPS - Sioux Falls.pdf PDF
S06 - Amend 0008 - RFP - 36C77624R0115 - SPS - Sioux Falls.pdf PDF
36C77624R0115 0007.pdf PDF
Amend 0007 - Att 01 - RFI Attachments.pdf PDF
Amend 0007 - Att 02 - RFI QandA.pdf PDF
S06 - Amend 0006 - Att 01- RFP - Sign-In Sheet - Site Visit - 04082025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0006 - RFP - 36C77624R0115 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0006 - Att 02 - Wage Rates - 03142025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0005 - RFP - 36C77624R0115 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0004 - RFP - 36C77624R0115 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0003 - RFP - Sign-in Sheet - Site Visit - 03252025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0003 - RFP - Site Visit Presentation - SPS - Sioux Falls.pdf PDF
S06 - Amend 0003 - RFP - 36C77624R0115 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - 36C77624R0115 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-05 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-02 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-08 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-03 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-09 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-07 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-11 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-10 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-01 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-06 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amend 0002 - RFP - Att 01-04 - DWG - 03242025 - SPS - Sioux Falls.pdf PDF
S06 - Amendment 0001 - SPS - Sioux Falls.pdf PDF
RFP - Att 02 - 02142025 - Specs - Vol I - SPS - Sioux Falls.pdf PDF
36C77624R0115_1.docx DOCX document
RFP - Att 01-01 - DWG - 02142025 - SPS - Sioux Falls.pdf PDF
Show 40 more

Latest 50 of 61 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ALIGN

ALIGN

ALIGN

AE301

L

M

N

O

SB

S2 X21 G.99

21 22 23 24 6

1S

0S

A2.1

5.3

J.99

30.6

30.5

G.2

A

C

A3.5

AE301

AE301

AE301

AE302

H11

SPS CHIEF

OFFICE

H10

ASSISTANT

CHIEF

OFFICE

H9

RME OFFICE H8

STAFF

LOUNGE

H6

HAC

C52

CORRIDOR

H5

LEAD TECH

OFFICE

H4

OPEN

OFFICE

C50

CORRIDOR

H23

DETERGENT

H22

SOILED HAC

H14

ANTE-ROOM

CLEAN

H16

CLEAN HAC

H15

CLEAN

WORKROOM,

ASSEMBLY

H24

CART

HOLDING

H25

ANTEROOM,

SOILED

TRANSITION/DROP-OFF

C50

CORRIDOR

H18

LOGISTICS

STORAGE

ROOM

H17

STERILE

INSTRUMENT

STORAGE

H1

TELECOM

H21

DECONTAMINATION

WORK AREA

C51

CORRIDOR

H7

TOILET

H20A

MANUAL

CART WASH

H20B

AUTOMATIC

CART WASH

AREA

H20

CART

HOLDING

H17A

SCOPE

STAGING

ROOM

H26

SCOPE

PROCESSING

DECONTAMINATION

ROOM

H2

CONFERENCE/

TRAINING

ROOM

AFF9'-0"

AFF9'-0"

AFF9'-0"

AFF9'-0"

AFF8'-6"

AFF8'-6"

AFF8'-6"

AFF9'-0"

AFF9'-0"

AFF9'-0"

AFF9'-0"

AFF8'-0"

AFF9'-0"

AFF8'-6"

AFF9'-0"

AFF9'-0"

AFF9'-0" AFF9'-0"

AFF9'-0"

AFF9'-0"

AFF8'-6"

AFF8'-6"

AFF8'-6"

AFF8'-9"

AE312

AE311

AE313

AE313

AE301

H13

WOMENS

TOILET/LOCKER

H12

MENS

TOILET/LOCKER

AE322

AE302

AFF9'-0"

AFF9'-0" AFF9'-0"

AFF8'-6"

AFF9'-0"

AE560

AE560

AFF8'-8"

AFF8'-8"

AFF8'-8"

AE560

AE560 AFF8'-2"

RC1

RC1

RC1

RC1

AE560

OPEN TO STRUCTURE

ABOVE

OPEN TO

STRUCTURE

ABOVE

OPEN TO

STRUCTURE

ABOVE

AFF6'-4" AFF6'-4"

AFF9'-0"

AFF9'-0"

A3

2 3 4 4.9

B

H

G

AFF8'-6"

AFF9'-0"

AE322

H15A

STEAM

STERILIZER

H19

STEAM

STERILIZATION

AREA

OPEN TO STRUCTURE

ABOVE

D

E

F

1.7 1.8 4.3 5 25 7 27

C.3

A1.1

A1.7

A2.9

A2.10

30.4

30.1

H13A

WOMENS

SHOWER

AFF9'-7"

C43

CORRIDOR

G29

STORAGE

G28

STORAGE

G27

OR #4

G26

CLEAN

CORE

G25

OR #1

G81-5

STAIR 9

G79-5

ELEVATOR

LOBBY

G02

CORRIDOR

G03

TELE

RC2

RC2

LIMITS OF CONSTRUCTION

LI

M

IT

S

O F

C O

N S

T R

U C

T

IO

N

LIM

ITS OF CONSTRUCTION

H3

ELECTRICAL

OPEN TO

STRUCTURE

ABOVE

H12A

MENS

SHOWER

AE560

AE560

TYP

AE560

AE550

SEE AC111 FOR

CEILING IN THIS AREA

AFF9'-0"

AFF11'-4"

AFF11'-4"

AFF8'-10"

FF

AE543

TYP

AFF9'-0"

8'-7 1/4"

AE560

1' -8

/4

AFF9'-0"

AE560

AFF8'-6"

RS-1

RS-1 RS-1 RS-1 RS-1

A1.0

AE560

AE560

RC1

RC1

RC3

RC3

AE560

AE543

TYP

AE543

SST HOOD AT WASHERS BY EQUIP SUPPLIER.

CJ

CJ

AE560

TYP

CAST STONE TO TERMINATE

AT THIS LOCTION. PROVIDE

FINISHED END.

RC1

EXISTING RADIANT PANEL

EXISTING LINIER LIGHTING

EXISTING LINIER LIGHTING

RC2

RC2

AFF9'-6"

AFF8'-0"

AFF8'-0"

AFF8'-0"

AFF9'-6"

AFF9'-0"

AFF9'-0"

G04

EMS

G42A

SHAFT

G05

ELEV EQUIP

RC2

RC2

AFF9'-6"

AFF9'-0"

RC2RC4

RC4

RC4

PROVIDE MOBILE ICRA CART FOR WORK IN THIS AREA.

REFLECTED CEILING PLAN SYMBOLS

NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN

GYP BD

CEILING /

SOFFIT

ACT CEILING

SYSTEM

EXISTING

ACT CEILING

SYSTEM

ACCESS

PANEL

2'-0" x 4'-0"

LIGHT FIXTURE

2'-0" x 2'-0"

LIGHT FIXTURE

PENDANT STRIP

LIGHT FIXTURE

EXISING 1'-0" X 2'-0"

LIGHT FIXTURE

RECESSED

LIGHT FIXTURE

MECHANICAL

SUPPLY GRILL

MECHANICAL

RETURN GRILL

WALL SCONCE

LIGHT FIXTURE

MECHANICAL

LINEAR SUPPLY

GRILL

CEILING

ELEVATION

9'-0" AFF

OR

EXISTING GYP

BD CEILING /

SOFFIT

EXISTING

RADIANT CEILING

PANEL

REFLECTED CEILING KEYED NOTES

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

RC1

18' X 18" MIN STAINLESS STEEL ACCESS PANEL. COORDINATE LOCATION

WITH MECHANICAL, ELECTRICAL AND PLUMBING AND PER SEPC SECTION

08 31 13

RC2

REMOVE AND REPLACE CEILING, INCLUDING ANY MECHANICAL /

ELECTRICAL CEILING MOUNTED ITEMS, IN THIS AREA AS REQUIRED FOR

MECHANICAL WORK. REPLACE ANY DIRTY OR DAMAGED ACT OR CEILING

GRID. SEE MEP PLANS FOR ADDITIONAL INFORMATION

RC3 STEEL CHANNEL AND STEEL POST. SEE DETAILS

RC4

LINE OF ICRA / CONSTRUCTION BARRIER, SEE SHEETS GC101 & GC111.

ALIGN EDGE OF STARC FIREBLOCK WALL SYSTEM TO EDGE OF CEILING

GRID. SEAL WALL SYSTEM AIR TIGHT TO CEILING GRID. CHECK SEAL TWICE

A DAY AND RESEAL AS NEEDED OR AS DIRECTED BY COR.

RCP GENERAL NOTES

1. GENERAL CONTRACTOR TO COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORT

REQUIREMENTS, LOCATIONS, DIMENSIONS, ETC WITH EQUIPMENT SUPPLIER AND OWNER,

PRIOR TO INSTALLATION.

2. ALL CEILING MOUNTED ITEMS SUCH AS LIGHT FIXTURES, GRILLES, DIFFUSERS, SPEAKERS, EXIT LIGHTS, ETC SHALL BE LOCATED IN THE CENTER OF ACT PANELS, GYP BD SOFFITS

AND/OR PLASTER SOFFIT BAYS, UNLESS NOTED OTHERWISE. COORDINATE WITH

MECHANICAL AND ELECTRICAL DRAWINGS.

3. FINISHED GYP BD SOFFITS SHALL EXTEND 1" BEYOND FACE AND EXPOSED ENDS OF WALL

CABINETS, FULL-HEIGHT CABINETS, ETC UNLESS NOTED OTHERWISE. COORDINATE CABINET

DIMENSIONS WITH SUPPLIER. GYP BD FASCIA/SOFFIT DETAILS ARE REFERENCED FROM THE

REFLECTED CEILING PLAN.

4. SEE MECHANICAL DRAWINGS FOR SPRINKLER HEAD TYPES AND LOCATIONS. CENTER ALL

HEADS IN ACT UNLESS NOTED OTHERWISE.

5. AT REMODELING WORK IN EXISTING ACT SUSPENSION SYSTEM, REMOVE EXISTING PANELS,

CUT AS REQUIRED FOR CONSTRUCTION AND RE-INSTALL. REPLACE ALL DAMAGED AND / OR

EXTREMELY SOILED PANELS WITH ACT TO MATCH EXISTING.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Name:

Tom Olesak

Date: 02/14/2025

License Number: 18157

2882 106th St, Urbandale, IA 50322

C U s e rs

\g b a rb a ri

\D o c u m e n ts \1

-R

G io v a n n i- B a rb a ri .r v t

/2

/2

:4

:5

P

M

AC101

GROUND LEVEL REFLECTED

CEILING PLAN

CONSTRUCT NEW SPS

Sioux Falls, SD.

438-460

02/14/2025 LA GJB16584

1/8" = 1'-0"

GROUND LEVEL REFLECTED CEILING PLAN

0 8' 16'4'

TRUE

NORTH

PLAN

NORTH

Revisions: Date:

Sheets
AC101 - GROUND LEVEL REFLECTED CEILING PLAN
AD111 - INTERSTITIAL/FIRST LEVEL DEMOLITION PLAN
AE111 - INTERSTITIAL/FIRST LEVEL FLOOR PLAN
GC111 - FIRST LEVEL INFECTION CONTROL & PHASING PLAN

File details come from the government source that posted it. Updated .