36C26122R0061 Modified Call for SF330s.docx

Standard Form DOCX document 20 KB Posted

Attached to
C1NB--Design Replace and Upgrade Boiler Plant Chilled and Hot Water Units | 612A4-22-006 | 612-22-2-7003-0012
Solicitation number
36C26122R0061
Issued by

About this file

This notice seeks Standard Form 330 submissions from architectural and engineering firms for a project to upgrade and expand an existing steam and hot water boiler plant and domestic hot water system at a Veterans Affairs medical center campus in California. Firms must submit qualifications by October 7, 2022. The project scope includes demolishing eight steam boilers, four hot water boilers, and replacing the domestic hot water system. Multiple engineering disciplines are required. The $10-20 million design contract is reserved for a Service-Disabled Veteran-Owned Small Business and will be awarded by December 31, 2022. The selected firm must complete construction documents within 490 calendar days. Qualifications will be evaluated based on experience, technical competence, capacity, past performance, and local knowledge.

View the file

Other versions and copies of SF 330S

File Revision Posted Attached to
Request for SF330s_CFM Healthcare A-E IDIQ_20260210.pdf Feb 10, 2026 Request for SF330s (Qualifications) for CFM Healthcare A-E IDIQ - 36C10F26R50011 -- C219
Request for SF330s_CFM Healthcare A-E IDIQ_20260204.pdf Feb 4, 2026 Request for SF330s (Qualifications) for CFM Healthcare A-E IDIQ - 36C10F26R50011 -- C219
Request for SF330s_CFM Healthcare A-E IDIQ_20260204.pdf Feb 4, 2026 Request for SF330s (Qualifications) for CFM Healthcare A-E IDIQ - 36C10F26R50011 -- C219
Request for SF330s_CFM Healthcare A-E IDIQ_ 20260114.pdf Jan 14, 2026 Request for SF330s (Qualifications) for CFM Healthcare A-E IDIQ - 36C10F26R50011 -- C219
Request for SF330s_CFM Healthcare A-E IDIQ_ 20260114.pdf Jan 14, 2026 Request for SF330s (Qualifications) for CFM Healthcare A-E IDIQ - 36C10F26R50011 -- C219
1305M226Q0061- Invitation to submit SF330s CLEAN.docx Revision not stated Invitation for SF 330s A&E Support for NOAA Marine Operations
Request for SF330s.pdf Revision not stated C211--CFM AE SERVICES IDIQ FOR VA NATIONAL CEMETERY PROJECTS
36C24626R0008 - Req for SF330s.pdf Revision not stated C223--Air Handlers with Auxiliary Chillers (A/E Design)
Responses to RFIs - Request for SF 330s VISN 16 FCA.pdf Revision not stated Request for A-E Qualifications (SF 330s) - VISN 16 Facility Condition Assessment -- C213
Responses to RFIs - Request for SF 330s VISN 9 FCA.pdf Revision not stated Request for A-E Qualifications (SF 330s) - VISN 9 Facility Condition Assessment -- C213
Request for SF330s VISN 16 FCA.pdf Revision not stated Request for A-E Qualifications (SF 330s) - VISN 16 Facility Condition Assessment -- C213
032 3Req SF330s AttB.pdf Revision not stated NOS OCM COASTAL GEOSPATIAL SERVICES
032 1Req SF330s.pdf Revision not stated NOS OCM COASTAL GEOSPATIAL SERVICES
032 4Req SF330s AttC.docx Revision not stated NOS OCM COASTAL GEOSPATIAL SERVICES
032 2Req SF330s AttA.pdf Revision not stated NOS OCM COASTAL GEOSPATIAL SERVICES
Request for SF330s - VISN 9 FCA.pdf Revision not stated Request for A-E Qualifications (SF 330s) - VISN 9 Facility Condition Assessment -- C213
Request for SF 330s 36C77625R0065.docx Revision not stated C1BG--EHRM Infrastructure Upgrades Construction Period Services - Northport, NY 632-22-700
Presolicitation Notice - Request for SF 330s.pdf Revision not stated C1DA--AE-NRM 668-25-102 Replace Asphalt Drywells and Sidewalks
Request for SF330s_CFM Healthcare A-E IDIQ DRAFT.docx Revision not stated VA CFM Healthcare A-E IDIQ -- C219
Request for SF330s_CFM Healthcare A-E IDIQ DRAFT.pdf Revision not stated VA CFM Healthcare A-E IDIQ -- C219
Show all 20

Who attaches SF 330S

Other files

File Type Posted
36C26122R0061-Call for 330s.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Modification to a Previous Notice Modification to a Previous Notice

SUBJECT*
Design Replace and Upgrade Boiler Plant Chilled and Hot Water Units | 612A4-22-006 | 612-22-2-7003-0012

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
94304
SOLICITATION NUMBER*
36C26122R0061

BASE NOTICE TYPE

RESPONSE DATE/TIME/ZONE
10-07-2022 1:00 pm PACIFIC TIME, LOS ANGELES, USA
ARCHIVE
99 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
C1NB
NAICS CODE*
541330
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

VA Sierra Pacific Network (VISN 21) Network Contracting Office 21 (NCO 21) 3801 Miranda Avenue Fresno CA 93721

POINT OF CONTACT*

Contracting Officer Denise R. Groves denise.groves@va.gov

PLACE OF PERFORMANCE

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

This is a revised Call for SF 330s. Please read the entire document.

The Department of Veterans Affairs VA Northern California Health Care System, CA (VANCHCS) is seeking Architectural/Engineering Firms to submit Standard Form (SF) 330 for Project 612A4-22-006, Design Replace and Upgrade Boiler Plant Chilled and Hot Water Units. The project will be located at VANCHCS Mather Campus, 10535 Hospital Way, Mather, California 95655.

I. DESCRIPTION OF REQUIREMENT

A. This project will upgrade and expand the existing steam and hot water boilers and domestic hot water system to create a consolidated central steam boiler plant facility. The project will also correct numerous condition deficiencies particularly those that relate to the essential electrical, plumbing, and mechanical systems needed for a fully functional central boiler plant. This design effort shall primarily consist of preparing complete construction documents (CD’s) for the consolidation of existing steam boilers and hot water boilers into a central steam boiler plant. Included in the scope of work is the demolition of existing eight (8) steam boilers, four (4) hot water boilers and the replacement of the domestic hot water system. A/E firm shall provide comprehensive analysis of the current space, function, workflow, and other design development requirements. The A/E is also required to plan for all equipment relocation and new equipment to be installed at the temporary space and within the newly renovated space. The design shall conform to the current Steam, Heating Hot Water, and Outside Distribution Systems design manual published by Department of Veterans Affairs. The design submittals shall be in accordance with the current version of Program Guide PG-18-15, Volume C. Both the program guide and design manual can be found on the VA Office of Construction & Facilities Management Technical Information Library (TIL) at Technical Information Library (TIL) - Office of Construction & Facilities Management (va.gov) B. The contract work requires multiple disciplines. The Prime firm shall be a licensed/registered professional firm and the lead designer in each discipline must be registered but neither need to be registered in California. The disciplines required include, but are not limited to: Architectural, Civil, Interior Design, Structural, HVAC, Plumbing, Electrical, Fire Protection, Construction Cost Estimating, Signage/Wayfinding, Landscaping and Geotechnical. Include any additional disciplines that may be necessary on the SF 330.

C. SF 330 Part 1F Example Projects; present all relevant VA projects first. Include in block 21 the contract number for all federal projects. Do not include the CPARS reports for federal projects.

D. The magnitude of construction for this project is between $10,000,000 and $20,000,000 E. Estimated Date of Award of the Design Contract: By December 31, 2022 F. Estimated design period of performance: Four hundred ninety (490) calendar days

II. SET-ASIDE

A. This procurement is a total Service-Disabled Veteran Owned Small Business (SDVOSB) set aside under the Veterans First Contracting program as required by 38 U.S.C. 8127-8128, as implemented under VA Acquisition Regulation (VAAR) subpart 819.70. The term Service-Disabled Veteran-Owned Small Business (SDVOSB) under the Veterans First Contracting program has the same meaning as Service-Disabled Veteran-Owned Small Business concern defined in FAR subpart 2.101, except for acquisitions authorized by 38 U.S.C. 8127 and 8128 for the Veterans First Contracting Program. These businesses must be listed as verified in the Vendor Information Pages (VIP) database at https://www.vip.vetbiz.gov in addition to meeting the small business size standard for NAICS 541330 ($22.5M) to be eligible for award under the Veterans First Contracting Program.

B. All SDVOSB firms that submit Standard Form (SF) 330s must be listed in Veterans Information Page (VIP) as a verified to be considered for this procurement. Offers from non-verified SDVOSBs are considered deficient and will not be evaluated further. A firm’s status will be verified in VIP at time of receipt of the SF 330, prior to conducting evaluations/interviews/discussions, and prior to award. This set aside process is in keeping with VA Procurement Policy Memorandum 2016-05 – Implementation of the Veterans First Contracting Program, FAR Part 19, and the requirements of FAR 36.6 for acquiring Architect-Engineer Services.

C. In part 1C of SF 330, indicate in block 11 the socio-economic status of that firm (SDVOSB/VOSB/WOSB ect)

III. SELECTION CRITERIA

A. Selection of firms for interviews and negotiations shall be based on an evaluation of the submitted SF 330s on the basis of the selection criteria listed below in a descending order of precedence. SF-330’s, Part I may be accompanied by any other evidence of experience and capabilities the applicant considers relevant. Part II shall be submitted for each proposed consultant’s office involved.

B. Selection Criteria descriptions are provided below.

i. Professional Qualifications Necessary for Satisfactory Performance of Required Services: Professional qualifications of the Project Manager(s), Designers of Record, and the proposed team. This will include the record of the proposed team have working together.

ii. Specialized Experience and Technical Competence: Specialized experience and technical competence required for this specific project, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. The effectiveness of the proposed project team, including management structure, and coordination of disciplines.

iii. Capacity: This factor evaluates the ability of the firm, given their current projected workload and the availability of their key personnel, to accomplish the possible myriad of design projects in the required time.

a. The general workload and staffing capacity of the design office will be evaluated.

b. In section H of the SF 330, list the current projects with a design fee of greater than $50,000 being designed in the prime firm’s office.

c. Indicate the firms’ present workload and the availability of the project team (including sub-consultants) for the estimated contract performance period.

iv. Past Performance: Past performance on recent (within 5 years of the due date of SF 330s) contracts with government agencies (emphasis on VA work) and private industry in terms of cost control, quality of work, compliance with performance schedules and record of significant claims against the firm. Where there is no record of past performance, the proposal will be evaluated neither favorably nor unfavorably. See I.C. above – do not include CPARS reports.

v. Geographical location and knowledge of the locality of the project: The physical location of the prime firm’s office as well as their familiarity of the building codes, environmental regulations, soil conditions, local construction methods/environment, and seismic requirements within the Sacramento California area.

vi. Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services.

vii. The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors

IV. SUBMISSION REQUIREMENTS:

A. No more than forty (40) pages B. Font size no smaller than 10 C. Size of emails not to exceed 10 MB. If more than one email is sent, number emails in subject line as 1 of 2, 2 of 2.

D. Completed and return VAAR 852.219-77 VA Notice of limitation on Subcontracting – Certificate of Compliance for Services and Construction (attached) E. Subject line of the email shall state “Company Name | Response to 36C26122R0061 | email 1 of 2 (if necessary)” F. In the body of the email include Prime Company Name; UEI Number, email address and phone number of primary point of contact

V. DUE DATE FOR SF 330

Firms that meet the requirements described in this announcement are invited to submit one (1) electronic copy of their SF 330 by 1:00 pm PT October 07, 2022, via email to Denise R. Groves, at denise.groves@va.gov. It is the intent of the Contracting Officer to make a single firm-fixed price contract award under this solicitation.

*= Required Field
Modification to a Previous Notice

Modification to a Previous Notice

File details come from the government source that posted it. Updated .