A /C
A /C
A/CA/C
A /C
EM
XF
XF
XF
XF
XF
XF
XF
XF
XF
HVP
PNL
PNL
HVP
HVP
HVP
HVP
PNL
PNL
GV
20' - 0"
STAGING & PARKING LEGEND
PROJECT LOCATION
STAGING AND DUMPSTER AREA
CONTRACTOR TRAILER AREA
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CLEMENT J. ZABLOCKI VAMC
#6 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
COR : MATTHEW OSGOOD 695-16-112
FIRE SPRINKLER ENGINEER
RTM CONSULTANTS, INC
6640 Parkdale Place, Suite J, Indianapolis, IN 46254
PHONE: (317) 329-7700
1220 N. PENNYSYLVANIA ST. SUITE 200 INDIANAPOLIS, IN. 46202
317.800.6388 WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
MILWAUKEE, WISCONSIN
C U s e rs
\j g o o d e n \D o c u m e n ts
\1 .1
.0
B ld g .S p ri n k le r R e p la c e m e n t -1
-1 v jg o o d e n g u id o n d e s ig n .c o m
.r v t
BID DOCUMENTS
GI000
KNLL
COVER SHEET
2019/04/24
14.1020.06
BUILDING 6 FIRE
SPRINKLER REPLACEMENT
BUILDING 6 SPRINKLER REPLACEMENT
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
BID DOCUMENTS
LOCATION MAP : NOT TO SCALE
CAMPUS MAP : NOT TO SCALE
N
N
PROJECT SITE:
BUILDING 6
CLEMENT J. ZABLOCKI
VA MEDICAL CENTER
CLEMENT J. ZABLOCKI
VA MEDICAL CENTER
CAMPUS
OWNER
DEPARTMENT OF VETERANS AFFAIRS
CONTACT: CHRISTIAN BRAUN, COR
(CONTRACTING OFFICER'S REPRESENTATIVE)
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295
PHONE: (414) 384-2000 X 46586
EMAIL: christian.braun@va.gov
ARCHITECT
GUIDON DESIGN, INC.
CONTACT: JAMES GOODEN, PROJECT MANAGER
1221 N. PENNSYLVANIA ST.
SUITE 200
INDIANAPOLIS, IN 46202
PHONE: (317) 800-6388 X 101
EMAIL: luke@guidondesign.com
FIRE PROTECTION
ENGINEER
RTM CONSULTANTS, INC.
CONTACT: CHRISTINA COLLESTER, P.E.
6640 PARKDALE PLACE
SUITE J
INDIANAPOLIS, IN 46254
PHONE: (317) 800-6388 X 112
EMAIL: collester@rtmconsultants.com
N
SCALE: 1" = 100'-0"GI000
1 BUILDING SITE
PROVIDE CONSTRUCTION DUMPSTER, AND LAY
DOWN AREA LOCATION. PROVIDE LOCKABLE
CHAIN LINK FENCE, GATE.
COORDINATE LOCATION WITH VA.
BUILDING 6
PROJECT LOCATION
CONTRACTOR
PARKING LOT
PROVIDE CONSTRUCTION TRAILER.
COORDINATE LOCATION WITH VA.
Sheet List
Sheet Number Sheet Name
GI000 COVER SHEET
GI001 GENERAL INFORMATION
GI201 PROJECT PHASING PLAN - BASEMENT
GI202 PROJECT PHASING PLAN - FIRST FLOOR
GI203 PROJECT PHASING PLAN - SECOND FLOOR
GI204 PROJECT PHASING PLAN - THIRD FLOOR AND ATTIC
GC101 BASEMENT FLOOR LEVEL 0 FLOOR PLAN
GC102 FLOOR LEVEL 1 FLOOR PLAN
GC103 FLOOR LEVEL 2 FLOOR PLAN
GC104 FLOOR LEVEL 3 AND ATTIC LEVEL FLOOR PLAN
FX101 FIRE SPRINKLER RISER LOCATIONS BASEMENT FLOOR PLAN 0
FX102 FIRE SPRINKLER SYSTEM RISER FLOOR 1 PLAN
FX103 FIRE SPRINKLER SYSTEM RISER FLOOR 2 PLAN
FX104 FIRE SPRINKLER SYSTEM RISER FLOOR 3 AND ATTIC PLAN
FX105 EXISTING FIRE SPRINKLER RISER DETAILS - WING A AND WING B
FX106 EXISTING FIRE SPRINKLER RISER DETAILS - WING C AND WING D
FX107 TEMPORARY COMBINED NEW & EXISTING FIRE SPRINKLER RISER DETAILS/PHASE 1
FX108 FINAL NEW FIRE SPRINKLER DETAILS
FA100 FIRE ALARM - MODIFICAITONS FOR SPRINKLER SYSTEM INTERFACE AND ELEVATOR CONTROL - BASEMENT FLOOR PLAN 0
FA200 FIRE ALARM - MODIFICAITONS FOR SPRINKLER SYSTEM INTERFACE AND ELEVATOR CONTROL - BASEMENT FLOOR PLAN DETAILS
GENERAL CONSTRUCTION NOTES
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING REVIT® SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING INFORMATION MODEL (BIM) HAS BEEN DEVELOPED FOR DESIGN COMMUNICATION. THE MODEL DOES NOT CONTAIN COMPLETE INFORMATION FOR USE IN COST ESTIMATING, SYSTEMS PERFORMANCE, COORDINATION, SCHEDULING, OR FACILITIES MANAGEMENT.
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE CONSTRUCTION SPECIFICATIONS
INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE NATIONAL CAD STANDARD AS GUIDES.
DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNER’S REPRESENTATIVE/COR. CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR GREATER QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT BE OBTAINED BY THE BID DUE DATE.
CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH OWNER’S REPRESENTATIVE/COR AND VARIOUS FACILITY PERSONNEL INVOLVED WITH UTILITY SHUT DOWN, INFECTION CONTROLS, OCCUPANT/EMPLOYEE
SAFETY, ACCESS CONTROL, ECT.
ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF THE PROJECT LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE DESIGN SCOPE OF WORK AND ACCESS TO EXISTING UTILITIES FOR TIE IN.
DRAWINGS ARE PREPARED FROM FIELD VERIFICATION, EXISTING FACILITY DRAWING BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS AND DETAILS OF SPECIFIC MANUFACTURERS AS A BASIS OF DESIGN. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ACTUAL DIMENSIONS, THE COORDINATION OF THE DETAILS WITH THE PRODUCTS WHICH ARE PROVIDED PER THE SCOPE OF THE SPECIFICATIONS AND THE SURROUNDING CONSTRUCTION.
CONTRACTOR SHALL VERIFY DIMENSIONS, ROUGH-IN DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION
REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE SCOPE OF WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL SUB-CONTRACTORS AND THE SCOPE OF WORK THEY PROVIDE. SUB-CONTRACTORS ARE RESPONSIBLE FOR THEIR FULL SCOPE OF WORK WITHIN THE CONTRACT DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY CERTAIN SHEETS AND SPECIFICATIONS, CROSS
COORDINATION IS REQUIRED.
CONTRACTOR AND SUB-CONTRACTOR’S ARE BOTH RESPONSIBLE FOR UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY NOTES, GENERAL NOTES, LEGEND, CODES, ECT., PROVIDED IN THE CONTRACT DOCUMENTS.
CONTRACTOR AND SUB-CONTRACTOR’S ARE BOTH RESPONSIBLE FOR PROVIDING AND MAINTAINING SMOKE/FIRE RATINGS OF NEW CONSTRUCTION AND EXISTING CONSTRUCTION AS INDICATED ON DRAWINGS. THIS INCLUDES PATCHING PENETRATIONS IN SHAFTS, WALLS, SLABS AND ROOF. ONLY U.L. AND/OR I.C.B.O. APPROVED METHODS, MATERIALS AND INSTALLATION ARE ACCEPTABLE.
MECHANICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION DRAWINGS SHOW INFORMATION IN A DIAGRAMMATIC FASHION WITHOUT DIMENSIONING. THE GENERAL CONTRACTOR IS TO COORDINATE THE LOCATIONS OF ALL MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT WITH RESPECT TO THE ARCHITECTURAL AND STRUCTURAL
DETAILING OF SHAFTS, CHASES, CEILING CONSTRUCTION, ETC.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED AND NOT IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING AND NEW CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND UNINSTALLED CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND EQUIPMENT. NOTIFY ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF ANY
DISCREPANCIES OR MISSING DIMENSIONS.
DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR GENERAL ORIENTATION AND CONTEXT ONLY.
THE TERM "ALIGN" MEANS TO INSTALL DIFFERENT/SIMILAR COMPONENTS OF CONSTRUCTION TO PROVIDE A FLUSH
FINISH SURFACE.
ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING MEMBERS, FACE OF NEW STRUCTURAL MEMBERS, FACE OF
NEW MASONRY, FACE OF NEW STUDS OR COLUMN GRID LINES UNLESS NOTED OTHERWISE.
FLOOR ELEVATION 0’-0” IS EQUAL TO THE FINISH FLOOR SLAB OF THE EXISTING SLAB FLOOR CONSTRUCTION.
ROUGH OPENINGS SHALL ALLOW FOR SHIM SPACE.
CONTRACTOR TO PROVIDE WORK WHERE DETAILS AND NOTES ARE IDENTIFIED AS “TYPICAL” OR “SIMILAR” EACH
INSTANCE THAT IS THE SAME IN NATURE TO THE DETAIL, AREA, OR ITEM REFERENCED.
PROVIDED WORK SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF DELIVERY, MOUNTING, INSTALLATION AND ROUGH-IN.
INSTALLED WORK IS THE CONTRACTOR INSTALLING OWNER FURNISHED MATERIALS AND EQUIPMENT. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF MATERIAL DELIVERY, MOUNTING, INSTALLATION AND ROUGH IN.
FURNISHED WORK IS THE CONTRACTOR FURNISHING THE MATERIALS AND EQUIPMENT TO THE OWNER. CONTRACTOR IS
RESPONSIBLE FOR COORDINATION OF DELIVERY AND ROUGH-IN.
ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS SPECIFICALLY CALLED OUT AS SALVAGED OR
RELOCATED WITHIN THE CONTRACT DOCUMENTS.
ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT SHALL BE FAMILIAR WITH THE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ACT, AND IMPLEMENT THOSE RULES AS THEY APPLY TO
THIS PROJECT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UTILITY LINES. LOCATIONS SHOWN ARE APPROXIMATE. REPAIR ALL DAMAGE TO UTILITY LINES CAUSED BY CONSTRUCTION OPERATIONS AT NO COST TO
THE OWNER.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING REQUIRED DURING
CONSTRUCTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT CONSTRUCTION, FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM THE CONSTRUCTION SITE. ANY DAMAGE OR UNACCEPTABLE WEAR BY THE CONSTRUCTION TEAM SHALL BE REPAIRED/REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER.
DESIGN TO BE IN ACCORDANCE WITH VA FIRE PROTECTION DESIGN MANUAL, DECEMBER 2015.
CONTRACTOR TO PROVIDE INFECTION CONTROL AND LIFE SAFETY MEASURES DURING CONSTRUCTION. DRAWINGS AND SPECIFICATIONS OUTLINE GENERAL PHASING AND DAILY PROTECTIVE MEASURES. CONTRACTOR TO PROVIDE ANY ADDITIONAL MEASURES THAT ALIGN WITH MEANS AND METHODS OF THE INSTALLATION OF THEIR FIRE PROTECTION
SYSTEM.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
CODE ANALYSIS
A. CONSTRUCTION CLASSIFICATION
1.THE BUILDING IS AN EXISTING 3-STORY BUILDING WITH A B (BUSINESS) OCCUPANCY.
2. THE PROJECT SCOPE DOES NOT CHANGE THE CONSTRUCTION TYPE OR EXPAND THE OVERALL BUILDING HEIGHT
OR ALLOWABLE AREA. (CHAPTER 5).
3. EXISTING BUILDING, ASSUME: TYPE III B, 3 STORY LIMIT
A. PRIMARY STRUCTURAL ELEMENTS ARE EXISTING TO REMAIN.
4. PARTIALLY SPRINKLED EXISTING BUILDING
B. FIRE RESISTANCE RATED SEPARATIONS
1. FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) (CHAPTER 6, TABLE 601)
EXISTING BUILDING, ASSUME:
PRIMARY STRUCTURE 0 HR
BEARING WALLS:
EXTERIOR 0 HR
INTERIOR 0 HR
NON-BEARING WALLS INTERIOR 0 HR
FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0 HR
ROOF CONSTRUCTION AND SECONDARY MEMBERS 0 HR
C. FIRE AND SMOKE PROTECTION FEATURES
1. FIRE BARRIERS AND SHAFT ENCLOSURES SHALL MEET TABLE 707.3.9 WHICH REQUIRES A 2-HOUR FIRE-
RESISTANCE RATING FOR B OCCUPANCIES.
2. EXISTING FIRE/SMOKE RATED BARRIERS SHALL BE MAINTAIN WITHIN PROJECT BOUNDARY.
3. NFPA 101 38.3.2 PROTECTION FROM HAZARDS. 38.3.2.1 GENERAL. HAZARDOUS AREAS INCLUDING, BUT NOT LIMITED TO, AREAS USED FOR GENERAL STORAGE, BOILER, FURNACE ROOMS, AND MAINTENANCE SHOPS THAT INCLUDE WOODWORKING AND PAINTING AREAS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 8.7.
EXISTING HIGH HAZARD AREAS WITHIN PROJECT BOUNDARY SHALL BE MAINTAINED.
4. NFPA 101. 8.7.1.1 PROTECTION FROM ANY AREA HAVING A DEGREE OF HAZARD GREATER THAT OF NORMAL TO THE GENERAL OCCUPANCY OF THE BUILDING OR STRUCTURE SHALL BE PROVIDED BY ONE OF THE FOLLOWING MEANS: (1) ENCLOSING THE AREA WITH A FIRE BARRIER WITHOUT WINDOWS THAT HAS A 1-HOUR FIRE RESISTANCE RATING IN ACCORDANCE WITH SECTION 8.3. (2) PROTECTING THE AREA WITH AUTOMATIC EXTINGUISHING SYSTEMS IN ACCORDANCE WITH SECTION 9.7. ALL STORAGE ROOMS WITHIN PROJECT BOUNDARY
SHALL BE PROTECTED BY ITEM 2.
D. INTERIOR FINISH
1. INTERIOR WALL AND CEILING FINISH TO BE DESIGNED IN ACCORDANCE WITH TABLE 803.11. (CHAPTER 8, TABLE 803.11)
2. NO CHANGE TO EXISTING FINISHES.
E. FIRE PROTECTION SYSTEMS
1. AUTOMATIC SPRINKLER SYSTEM IS PROVIDED WITHIN THE BUILDING AND SHALL BE MODIFIED IN COMPLIANCE WITH
NFPA 13. (CHAPTER 9, (F) 903.2.11.4)
2. NFPA 101, 38.3.5 EXTINGUISHING REQUIREMENTS. PORTABLE FIRE EXTINGUISHERS SHALL NOT BE RELOCATED
WITHIN
THE PROJECT SCOPE.
3. FIRE ALARM AND DETECTION SYSTEMS IS AN EXISTING SYSTEM AND SHALL BE BROUGHT TO CURRENT NFPA 72 .
4. NFPA 101. 38.3.4.1 DETECTION, ALARM AND COMMUNICATIONS SYSTEMS. GENERAL. A FIRE ALARM SYSTEM IN ACCORDANCE WITH SECTION 9.6 SHALL BE PROVIDED IN ALL BUSINESS OCCUPANCIES WHERE (2) THE OCCUPANCY
IS SUBJECT TO 50 OF MORE OCCUPANTS ABOVE OR BELOW THE LEVEL OF EXIT DISCHARGE.
5. NFPA 101. 38.3.4.2 INITIATION. INITIATION OF THE REQUIRED FIRE ALARM SYSTEM SHALL BE BY ANY ONE OF THE FOLLOWING MEANS (3) APPROVED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH 9.6.2.1(3) THAT PROVIDES
PROTECTION THROUGH THE BUILDING AND PROVISIONS 9.6.2.6 SHALL APPLY.
6. NFPA 101. 38.3.4.3 OCCUPANT NOTIFICATION. DURING ALL TIMES THAT THE BUILDING IS OCCUPIED THE REQUIRED
FIRE
ALARM SYSTEM, ONCE INITIATION SHALL PERFORM ON OF THE FOLLOWING FUNCTIONS: (1) IT SHALL ACTIVATE A GENERAL ALARM IN ACCORDANCE WITH 9.6.3. (2) A POSITIVE ALARM SEQUENCE IN ACCORDANCE WITH 9.6.3.4 SHALL
BE PERMITTED.
7. NFPA 101. 38.3.4.4. EMERGENCY FORCES NOTIFICATIONS. EMERGENCY FORCES SHALL BE PROVIDED AND SHALL INCLUDE NOTIFYING BOTH OF THE FOLLOWING: (1) FIRE DEPARTMENT IN ACCORDANCE WITH 9.6.4. (2) APPROVED
LOCAL EMERGENCY ORGANIZATION, IF PROVIDED.
F. MEANS OF EGRESS
MEANS OF EGRESS. THE BUILDING IS EQUIPPED WITH AN AUTOMATED SPRINKLER SYSTEM.
1. MAXIMUM TRAVEL DISTANCE: 300 FEET
2. COMMON PATH OF TRAVEL: 50 FEET
3. DEAD ENDS: 50 FEET
4. CORRIDORS: TABLE 1018.1: CORRIDORS ARE NOT REQUIRED TO BE RATED.
5. EXISTING MEANS OF EGRESS SHALL NOT BE MODIFIED WITHIN PROJECT SCOPE.
H. TEMPORARY SMOKE BARRIER WALL CONSTRUCTION , NFPA 241. A TEMPORARY SMOKE BARRIER WALL
CONSTRUCTION
WILL BE CONSTRUCTED IN LOCATION IDENTIFIED IN THE GI PHASING PLANS TO SEPARATE PHASES OF WORK WERE THE FIRE SPRINKLER WILL BE TEMPORARILY SHUT DOWN, PROVIDING ISOLATION AND PROTECTION BETWEEN BUILDING AREAS. REFER TO SPECIFICATIONS AND DETAIL 1/GI001 AND 2/GI101 FOR WALL CONSTRUCTION INFORMATION.
REFER TO VA MANUAL PG-18-3 FOR ADDITIONAL CODES, STANDARDS, GUIDELINES AND REGULATIONS, BELOW LISTING IS NOT
COMPREHENSIVE.
ICC, INTERNATIONAL BUILDING CODE, 2015 EDITION (IBC)
ICC, INTERNATIONAL PLUMBING CODE, 2015 EDITION (IPC)
ASCE-07-10
ACI 318-11
ACI 530-11
AISC 341-10
AISC 360-10
PCI MNL 120-10, DESIGN HANDBOOK
NFPA 101, LIFE SAFETY CODE, 2018 EDITION (LSC).
NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2019 EDITION.
NFPA 14, STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEM, 2019 EDITION.
NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2018 EDITION.
NFPA 20, STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION, 2019 EDITION.
NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCE, 2019 EDITION.
NFPA 70, NATIONAL ELECTRIC CODE, 2017 EDITION.
NFPA 72, NATIONAL FIRE ALARM CODE, 2019 EDITION.
NFPA 75, STANDARD FOR THE PROTECTION OF ELECTRICAL COMPUTER/DATA PROCESSING EQUIPMENT, 2017 EDITION.
NFPA 77, RECOMMENDED PRACTICE ON STATIC ELECTRICITY, 2019 EDITION.
NFPA 80, STANDARD FOR FIRE DOORS AND FIRE WINDOWS, 2019 EDITION.
NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2018 EDITION.
NFPA 92A, RECOMMENDED PRACTICE FOR SMOKE CONTROL SYSTEMS, 2009 EDITION.
NFPA 92B, GUIDE FOR SMOKE MANAGEMENT SYSTEMS IN MALLS, ATRIA, AND LARGE AREAS, 2009 EDITION.
NFPA 99, STANDARD FOR HEALTHCARE FACILITIES, 2018 EDITION.
NFPA,99B, STANDARD FOR HYPOBARIC FACILITIES, 2018 EDITION.
NFPA 101, LIFE SAFETY CODE, 2018 EDITION.
NFPA 110, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS, 2019 EDITION.
NFPA 220, STANDARD TYPES OF BUILDING CONSTRUCTION, 2018 EDITION.
NFPA 780, STANDARD FOR INSTALLATION OF LIGHTING PROTECTION SYSTEMS, 2017 EDITION.
NFPA 54 TYPE 2 CLOTHES DRYER UL 705 DEDPY, 2018 EDITION.
ASHRAE 90.1-2007 HVAC SYSTEMS
ASHRAE 189.1 -2009 STANDARD FOR THE DESIGN OF HIGH PERFORMANCE GREEN BUILDINGS
ASHRAE 180 - 2009 VENTILATION FOR HEALTH CARE FACILITIES
ASHRAE 62.1 - 2007 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
ASHRAE 1.1 - 2007 HVAC & R TECHNICAL REQUIREMENTS FOR COMMISSIONING PROCESS
ASHRAE 0 - 2005 COMMISSIONING PROCESS
ASHRAE 55- 2004 THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY
ANSI A117.1-2009 STANDARD ON ACCESSIBLE & USABLE BUILDINGS AND FACILITIES
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
2012 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES
BELOW)
2012 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
MOST RECENT EDITION OF NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900 OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
NATIONAL ELECTRICAL CODE (NEC)
INTERNATIONAL PLUMBING CODE (IPC)
ENERGY POLICY ACT OF 2005 (EPACT)
EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND TRANSPORTATION MANAGEMENT.
VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1- 2004.
SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15 – 2007.
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/). ALL OF THE MOST RECENT VERSIONS
OF THE DOCUMENTS SHOULD BE USED FOR REFERENCE.
VA MENTAL HEALTH FACILITIES DESIGN GUIDE DECEMBER 2010
VA BARRIER FREE DESIGN GUIDE PG-18-13, ABAAS
ARCHITECTURAL, AUGUST 1, 2014
ASBESTOS ABATEMENT, JULY 2011
CMP SCHEDULE AND RISK MANAGEMENT, VOL. 1 & 2, DECEMBER 2011 2012
ELECTRICAL, DECEMBER 2015
ENERGY REDUCTION/ SUSTAINABILITY, MAY 2014
EQUIPMENT, JUNE 2006
ESTIMATING, MARCH 8, 2011
NFPA INTERIM GUIDANCE FOR PROJECTS, PG-18-17, SEPTEMBER 30, 2010
FIRE PROTECTION, SIXTH EDITION REVISED SEPTEMBER 2011
HVAC FOR NEW, REPLACEMENT, ADDITION AND RENOVATION OF EXISTING CA FACILITIES, MARCH 2011
INTERIOR DESIGN, MAY 2008
PHYSICAL SECURITY DESIGN MANUAL: LIFE-SAFETY PROTECTED FACILITIES, JANUARY 2015
PLUMBING, NOVEMBER 2014
STRUCTURAL, FEBRUARY 1, 2014
WAY FINDING AND SIGNAGE, INTERIOR DECEMBER 2012
SEISMIC DESIGN REQUIREMENTS, H-18-8
ENVIRONMENTAL PLANNING GUIDANCE PG-18-17
VA DESIGN MANUALS PG-18-10:
GOVERNING CODES:
INFECTION CONTROL PROJECT INFORMATION
REFER TO SPECIFICATION 010110 FOR ADDITIONAL REQUIREMENTS.
PROVIDE IC PLANS AND FACILITATE MEETING WITH VA PATIENT SAFETY AND INFECTION CONTROL STAFF PRIOR TO INSTALLATION OF TEMPORARY SMOKE BARRIER WALL FOR APPROVAL OF LOCATION AND PROTOCOLS. PLAN SHALL NOT
BLOCK OR HINDER THE USE OF THE BUILDINGS BY PATIENTS OR USERS.
PROVIDE THE FOLLOWING INFECTION CONTROL MEASURES, A 24"X36" STICKY WALK OFF MAT AND HAND SANITIZER AT
EACH TEMPORARY DOOR LOCATION. MAT SHALL BE REPLACED OR CLEANED AS NECESSARY
PROVIDE THE REQUIRED VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH TEMPORARY DOOR LOCATION.
CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC, MULTI-PURPOSE SPILL CONTROL SORBENTS
TO ABSORB NON AGGRESSIVE LIQUIDS UP TO 30 GALLONS.
ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED WITH 4 MIL. POLY SHEET.
ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSED WITH A LID.
ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY STORED IN DESIGNATED AREAS AND
APPROVED CONTAINERS. FLAMMABLE MATERIALS SHALL NOT BE STORED IN THE FACILITY.
TEMPORARY SMOKE BARRIER WALL CONSTRUCTION DOES NOT ELIMINATE THE REQUIREMENT FOR INFECTION CONTROL DUST WALL BARRIE BEING REQUIRED FOR WORK WITHIN PHASED AREAS WHICH WILL BE OCCUPIED DURING
CONSTRUCTION.
A PROFESSIONAL CLEANING CREW SHALL BE PROVIDED BY CONTRACTOR TO CLEAN THE CONSTRUCTION AREA EVERY MORNING AFTER WORK IS COMPLETE BEFORE OCCUPANTS OCCUPY THE BUILDING FOR THE WORK DAY.
PROVIDE PLASTIC DUSTWALL CONSTRUCTION AT OPENINGS AND TAPE DOORS TO SEAL PROJECT AREAS AT THE START OF WORK EACH EVENING AND REMOVE AND UNSEAL EACH MORNING. REFER TO IC SPECIFICATION FOR ADDITIONAL
INFORMATION.
COVER EQUIPMENT AND OFFICE FURNITURE AT THE START OF WORK SHIFT AND UNCOVER AT THE END. EQUIPMENT AND FURNITURE TO REMAIN WHERE IT IS. RELOCATION TO BE REIVEWED WITH COR TWO WEEKS PRIOR FOR NEED OF
RELOCATION FOR APPROVAL.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
INFECTION CONTROL GENERAL NOTESPATIENT RISK GROUP: LOW RISK, OFFICE
CLASS OF PRECAUTION: III
CONSTRUCTION PROJECT TYPE: D
DURING CONSTRUCTION WORK
1. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION OF
DUCT SYSTEM .
2. COMPLETE ALL CRITICAL BARRIERS I.E. SHEET ROCK, PLYWOOD,PLASTIC, TO SEAL AREA FROM NON WORK AREA OR IMPLEMENT CONTROL TUBE METHOD ( CART WITH PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE
WITH HEPA VACUUM FOR VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR FILRATION UNITS.
4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.
5. COVER TRANSPORT RECEPTABLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
UPON COMPLETION OF CONSTRUCTION WORK, BEFORE SPACE OCCUPED BY STAFF
1. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION PREVENTION & CONTROL DEPARTMENT AND THROUGHLY CLEANED BY THE
OWNER'S ENVIROMENTAL SERVICES DEPARTMENT.
2. REMOVE BARRIERS MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH
CONSTRUCTION.
3. VACUUM WORK AREA WITH HEPA FILTERED VACUMMS.
4. WET MOP AREA WITH CLEANER/DISINFECTANT.
5. UPON, COMPLETION, RESTORE HVAC SYSTEM WHERE WORK WAS PERFORMED.
CLASS OF PRECAUTION: III
TYPE D
LIMITED FIRE RISK
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS.
INCLUDES, BUT IS NOT LIMITED TO:
• ACTIVITIES WHICH REQUIRE CONSECUTIVE WORK SHIFTS.
• REQUIRES HEAVY DEMOLITION OR REMOVAL OF A COMPLETE CABLING SYSTEM.
• NEW CONSTRUCTION.
CONSTRUCTION PROJECT TYPE: D
TYPE III
DURING CONSTRUCTION PROJECT UPON COMPLETION OF PROJECT
1. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE
WORK IS BEING DONE TO PREVENT CONTAMINATION OF
DUCT SYSTEM .
2. COMPLETE ALL CRITICAL BARRIERS I.E. SHEET ROCK,
PLYWOOD,PLASTIC, TO SEAL AREA FROM NON WORK A
REA OR IMPLEMENT CONTROL TUBE METHOD ( CART
WITH PLASTIC COVERING AND SEALED CONNECTION TO
WORK SITE WITH HEPA VACUUM FOR VACUUMING
PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE
UTILIZING HEPA EQUIPPED AIR FILRATION UNITS.
4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT
IN TIGHTLY COVERED CONTAINERS.
5. COVER TRANSPORT RECEPTABLES OR CARTS. TAPE
COVERING UNLESS SOLID LID.
UPON COMPLETION OF CONSTRUCTION WORK, BEFORE
SPACE OCCUPED BY STAFF
1. DO NOT REMOVE BARRIERS FROM WORK AREA
UNTIL COMPLETED PROJECT IS INSPECTED BY
THE OWNER'S SAFETY DEPARTMENT AND
INFECTION PREVENTION & CONTROL DEPARTMENT
AND THROUGHLY CLEANED BY THE OWNER'S
ENVIROMENTAL SERVICES DEPARTMENT.
2. REMOVE BARRIERS MATERIALS CAREFULLY TO
MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
3. VACUUM WORK AREA WITH HEPA FILTERED
VACUMMS.
4. WET MOP AREA WITH CLEANER/DISINFECTANT.
5. UPON, COMPLETION, RESTORE HVAC SYSTEM
WHERE WORK WAS PERFORMED.
A/C AIR CONDITIONING
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
A&E ARCHITECT AND ENGINEERS
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITIES HAVING JURISDICTION
AHU AIR HANDLING UNIT
ALT ALTERNATIVE
ALT TRANS ALTERNATIVE TRANSPORTATION
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AVG AVERAGE
BB BULLETIN BOARD
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOD BASIS OF DESIGN
BRG BEARING
CB CATCH BASIN
CBB CEMENTITIOUS BACKER BOARD
CER CERAMIC
CF CUBIC FEET
CFCI CONTRACTOR FURNISH CONTRACTOR INSTALL
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD
C & G CURB & GUTTER
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNITS
CO CLEANOUT(S)
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
CP CONCRETE PIPE
CPT CARPET
CR CRASHRAIL
CRS COLD ROLLED STEEL
CS CAST STONE
CSB CONCRETE SPLASH BLOCK
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CT CERAMIC TILE
CTR CENTER
CU FT CUBIC FEET
CUH CABINET UNIT HEATER
CY CUBIC YARD
D DRYER
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DISP DISPENSER
DIV DIVISION
DN DOWN
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
E EAST
(E) EXISTING
EA EACH
EF EXHAUST FAN
EFTR EXISTING FINISH TO REMAIN
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATED
ETR EXISTING TO REMAIN
ETS EXPOSED TO STRUCTURE
ARCHITECTURAL ABBREVIATIONS
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FF & E FURNITURE FIXTURES & EQUIPMENT
FIN FINISH
FIXT FIXTURE
FL FLOW LINE
FLR FLOOR
FLUOR FLUORESCENT
FO FINISH OPENING
FOS FACE OF STUD
FR FIRE RATED
FSP FIRE STANDPIPE
FT FOOT / FEET
FTG FOOTING
FURR FURRING
FV FIELD VERIFY
FVC FIRE VALVE CABINET
FWC FABRIC WALLCOVERING
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GARBAGE DISPOSAL
GF CMU GROUND FACE CMU
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GI GALVANIZED IRON
GL GLASS
GL BLK GLASS BLACK
GLU LAM GLUE LAMINATED WOOD
GND GROUND
GT GROUT
GYP BD GYPSUM BOARD
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIB
HC HOLLOW CORE
HCP HANDICAPPED
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR, HANDRAIL
HT HEIGHT
HVAC HEATING, VENTILATING & AIR CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IG INSULATING GLASS
IN INCH
INCAN INCANDESCENT
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INV INVERT
ITG INSULATED TEMPERED GLASS
JAN JANITOR
J-BOX JUNCTION BOX
JT JOINT
L LONG
LAV LAVATORY
LB(S) # POUND(S)
LF LINEAL FEET
LLV LONG LEG VERTICAL
LT LIGHT
LVR LOUVER
M & BH MOP AND BROOM HOLDER
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL
MEPF MECHANICAL, ELECTRICAL, PLUMBING,
FIRE PROTECTION (CONDUIT)
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MSB MOP SERVICE BASIN
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NECY NECESSARY
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER,
OVERFLOW DRAIN
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED
OWNER INSTALLED
OH OPPOSITE HAND
OPN OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
P PAINT
PARTN PARTITION
PBD PARTICLE BOARD
PBSW PATIENT BED SERVICE WALL
PCC PRECAST CONCRETE
PI INPATIENT PSYCHIATRIC
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PMU PSYCHIATRIC MEDICAL UNIT
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT CONC POST-TENSIONED CONCRETE
PTD PAPER TOWEL DISPENSER
PTL PORCELAIN TILE
PVC POLYVINYL CHLORIDE
QA QUALITY ASSURANCE
QT QUARRY TILE
R R-VALUE (INSULATION),
RADIUS, RISER
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE: REFERENCE
REBAR REINFORCING BAR
REC RECESSED
RECPT RECEPTACLE
REF REFRIGERATOR
REG REGISTER
REINF REINFORCE
REQD REQUIRED
RESIL RESILIENT
REV REVISION
RFT RESILIENT FLOOR TILE
RH ROOF HATCH
RM ROOM
RO ROUGH OPENING
RT RUBBER STAIR TREAD
S SOUTH
SAF SEAMLESS ACRYLIC FLOORING
SAP SUSPENDED ACOUSTICAL PANELS
SAT SUSPENDED ACOUSTICAL TILE
SB SPLASHBLOCK
SC SEALED CONCRETE, SOLID CORE
SCHED SCHEDULE
SCP SCUPPER
SD SOAP DISPENSER
SEAL SEALER
SECT SECTION
SECT SECTION
SF SQUARE FOOT
SF CMU SPLIT-FACE CMU
SHR SHOWER
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SL SLOPE
SLV SHORT LEG VERTICAL
SND SANITARY NAPKIN DISPOSER
SNV SANITARY NAPKIN VENDOR
SPECS SPECIFICATIONS
SQ SQUARE
SS SOLID SURFACE
SST STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
TB TACKBOARD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
TD TUBULAR DAYLIGHTING DEVICE
TEL TELEPHONE
TEMP TEMPERATURE
TG TEMPERED GLASS,
TONGUE & GROOVE,
TRANSFER GRILLE
THRU THROUGH
TO TOP OF
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TTD TOILET TISSUE DISPENSER
TV TELEVISION
TYP TYPICAL
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
URN URINAL
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDP WOOD PANELING
WDW WINDOW
WF WIDE FLANGE
WGL WIRED GLASS
WH WATER HEATER
WR WASTE RECEPTACLE,
WATER RESISTANT
WS WATER STOP
WSCT WAINSCOTT
WT WEIGHT
WWF WELDED WIRE FABRIC
ARCHITECTURAL SYMBOLS
X
X
XXXX
SHEET LOCATION
VIEW NUMBER
X X
X
SHEET LOCATION
VIEW NUMBER
XXXX
SECTION REFERENCE DRAWING NUMBER
SHEET LOCATION
DRAWING NUMBER
SHEET LOCATION
DETAIL REFERENCE
OBJECT
REFERENCED
OBJECT
REFERENCED
ELEVATION REFERENCES
X
XXXX
X
XXXX
SCALE: ??
VIEW TITLE
HANDICAP SYMBOL
N
TRUE NORTH ARROW
ROOM
101 ROOM TAG
X
1 PLAN NOTE
ALTERNATE/BID DEDUCT ITEM
EXISTING WALL TO REMAIN
EXISTING DOOR
TEMPORARY IC BARRIER WALL
CONSTRUCTION (DUST WALL) OR
TEMPORARY SMOKE BARRIER WALL
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CLEMENT J. ZABLOCKI VAMC
#6 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
COR : MATTHEW OSGOOD 695-16-112
FIRE SPRINKLER ENGINEER
RTM CONSULTANTS, INC
6640 Parkdale Place, Suite J, Indianapolis, IN 46254
PHONE: (317) 329-7700
1220 N. PENNYSYLVANIA ST. SUITE 200 INDIANAPOLIS, IN. 46202
317.800.6388 WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
MILWAUKEE, WISCONSIN
C U s e rs
\j g o o d e n \D o c u m e n ts
\1 .1
.0
B ld g .S p ri n k le r R e p la c e m e n t -1
-1 v jg o o d e n g u id o n d e s ig n .c o m
.r v t
BID DOCUMENTS
GI001
KNLL
GENERAL INFORMATION
2019/04/24
14.1020.06
BUILDING 6 FIRE
SPRINKLER REPLACEMENT
RAMP
A
B
C
D
E
F
I
G
1 3 4
5 76
2 8 9 10
11 12 13
H
R A M P
A C
A C
A C
A C
U P
U P
D N
R A M P
D N
U P
U P
D O W N
D O W N
U P
U P
U P
U P
U P
U P
U P
R A M P
U P
U P
R A M P
U P
U P
U P
U P
U P
R A M P
U P
U P
U P
U P
U P
RM
AB 11
ROOM
AB 13
RM
AB 04
RM
AB 05
RM
AB 06
RM
AB 07
RM
CB 05
RM
CB 07
RM
CB 05
RM
CB06
RM
CB10
RM
CB 02
RM
CB 11
RM
CB 16
RM
CB 15
CORRIDOR
A / B
R A
M P
R A
M P
RM
AB 08
RM
AB 09
MECHANICAL
RM
AB07-A
MECHANICAL
RM
AB07-B
ELEVATOR
A
RM
AB 14
ROOM
AB 01
RM
BB 03
RM
BB 02
RM
BB 06
RM
BB 04
RM
BB 05
RM
BB 01
RM
CB 12-B
RM
CB 12-A
RM
CB 17
ABANDONED
REFRIG./
FREEZER
RM
CB 14A
RM
CB 18
RM
CB 21
RM
DB 02
RM
DB 03
RM
DB 04
RM
DB 01
RM
DB 05
RM
DB 06
RM
CB 19
RM
CB 20
RM
CB 14
RM
CB 08
RM
CB 09
ELECTRICAL
CLOSET
STAIR
A1
STAIR
B1
STAIR
C2
STAIR
C1
STAIR
D
WAREHOUSE
TEMPORARY
CB22
ELEVATOR
C2
RM
CB 17
ABANDONED
REFRIG./
FREEZER
ELEVATOR
C1
CORRIDOR
C / D
2a
2a
EXIT
EXIT
EXIT
EXIT EXIT
EXIT
EXIT
EXIT
EXIT
100'
TRAVEL
DISTANCE
OPEN
WOOD
WOOD
METAL CEILING
OPEN
BUILDING 6
WING A
BUILDING 6
WING B
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
BUILDING 6
WING A
BUILDING 6
WING B
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
LIFE SAFETY LEGEND
1 HR HAZARD AREA & 1 HR SMOKE BARRIER
2HR EXIST. SHAFT WALL & 2 HR BUILDING
SEPARATION
TRAVEL DISTANCE
EXIT EGRESS EXIT
THE BUILDING OCCUPANCY, OCCUPANCY LOAD, MEANS OF EGRESS AND FIRE
EXTINIGUSHER LOCATIONS ARE NOT BEING MODIFIED WITHIN THIS PROJECT.
THE PROJECT SCOPE OF WORK DOES NOT ANTICIPATE DISRUPTION
OF EXISTING HAZARDOUS MATERIALS. IF EXISTING PIPING INSULATION
ON PIPES AROUND SPRINKLER PIPING IS EXPOSED DURING
CONSTRUCTION NOTIFY COR AND REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
LEAD PAINT IS WITHIN THE BUILDING, THE PROJECT SCOPE
ANTICIPATED MINIMAL DISRUPTION OF THE EXISTING LEAD PAINT.
CONTRACTOR TO NOTIFY COR IF EXISTING PAINT SURFACE IS TO BE
BROKEN, CHIPPED, OR MODIFIED IN ANY WAY. REFER TO
SPECIFICATION FOR ADDITIONAL INFORMATION.
NO ASBESTOS PIPING INSULATION OR DI-ELECTIC UNIONS ARE
ANTICIPATED TO BE REMOVED WITHIN THE PROJECT SCOPE.
1.
2.
3.
HAZARDOUS MATERIAL GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
FLOOR PLAN GENERAL NOTES
BUILDING 6 IS A NATIONAL REGISTERED HISTORIC BUILDING. REF. NO.
70920.
CEILINGS ARE OPEN TO PLASTER CEILINGS THROUGH OUT PROJECT
SCOPE UNLESS OTHERWISE IDENTIFIED, REFER TO FLOOR PLANS FOR
ACOUSTIC PANEL CEILING LOCATIONS AND TYPE.
PLASTER CEILINGS SHALL BE PATCHED, PREPPED AND NEW PAINT
FINISH APPLIED TO MATCH EXISTING WHERE FIRE SPRINKLER
PROTECTION REPLACEMENT HAS CAUSED DAMAGE. PAINT CEILING
WITHIN ROOM BOUNDRY.
WHERE ACOUSTIC PANEL CEILING REMOVED IN ORDER TO COMPLETE
ABOVE CEILING WORK SHALL BE STORED IN A SAFE DRY LOCATION
SUCH AS THE CONTRACTOR PROVIDED JOB TRAILER.
DAMAGED OR BROKEN CEILING TILES SHALL BE REPLACED TO MATCH
EXISTING. REFER TO FLOOR PLANS FOR ACOUSTIC PANEL CEILING
LOCATIONS AND TYPE.
CEILING TILES WITH PENETRATIONS TO ACCOMMODATE ORIGINAL
FIRE SPRINKLER SYSTEM HEADS SHALL BE REPLACED WITH NEW
ACOUSTIC PANEL CEILING PADS.
AT THROUGHFLOOR PENETRATIONS CREATED FROM REMOVED
PIPING PROVIDE METAL PLATE ON UNDERSIDE OF FLOOR SLAB
WHERE CONCRETE INFILL IS REQUIRED. CHIP AWAY CONCRETE AT
FLOOR LEVEL TO CREATE A SLOPED OPENING/LIP TO PATCH
PENETRATIONS AND PREVENT CONCRETE INFILL CORE FROM FALLING
THROUGH OPENING TO FLOOR BELOW.
PATCH AND PREP AREA OF WALLS AND CEILING WHERE PIPING IS
REMOVED AT THROUGHWALL PENETRATIONS AND IS NOT REPLACED.
PATCH SHALL MATCH WALL CONSTRUCTION. PROVIDE PAINT TO
MATCH EXISTING AND WALL SHALL BE PAINTED FROM FLOOR TO
CEILING AND CORNER TO CORNER.
EXISTING FURNITURE AND EQUIPMENT SHALL BE COVERED AND
PROTECTED WITHIN AREAS OF WORK BEING COMPLETED. PROJECT
AREA SHALL BE PROFESSIONALLY CLEANED AND READY FOR OWNER
OCCUPANCY BY 5:00 AM.
PROVIDE CORE DRILLED PENETRATIONS THROUGH THE STAIRWAYS
AS REQUIRED BY THE SPRINKLER SHOP DRAWINGS FOR NEW RISER
AND DRAIN LINES. A TOTAL OF 4 STAIRWAY. REFER TO FLOOR PLAN
NOTES AND FIRE SPRINKLER ENGINEERING DRAWINGS FOR
ADDITIONAL INFORMATION.
FIRE SPRINKLER PIPE SHALL BE CONCEALED IN LOCATIONS WITH
ACOUSTIC PANEL CEILINGS.
FIRE SPRINKLER PIPE SHALL BE PAINTED RED PER SPECIFICATIONS IN
LOCATIONS WITH OPEN PLASTER CEILINGS.
FIRE SPRINKLER DESIGN HAS BEEN DESIGNED IN A WAY TO UTILIZE
EXISTING WALL AND FLOOR PENETRATIONS. IF A NEW PERPETRATION
IS REQUIRED LEAD, ASBESTOS TESTING AND ABATEMENTS SHALL BE
PROVIDED BY CONTRACTOR. ASSUME 24 PENETRATIONS REQUIRED, 2
PER FLOOR PER WING.
PROVIDE PLASTIC DUSTWALL CONSTRUCTION AT OPENINGS AND
TAPE DOORS TO SEAL PROJECT AREAS AT THE START OF WORK
EACH EVENING AND REMOVE AND UNSEAL EACH MORNING. REFER TO
IC SPECIFICATION FOR ADDITIONAL INFORMATION.
COVER EQUIPMENT AND OFFICE FURNITURE AT THE START OF WORK
SHIFT AND UNCOVER AT THE END. EQUIPMENT AND FURNITURE TO
REMAIN WHERE IT IS. RELOCATION TO BE REIVEWED WITH COR TWO
WEEKS PRIOR FOR NEED OF RELOCATION FOR APPROVAL.
ROOM IS PROVIDED WITH A 2X2 ACOUSTIC GRID CEILING AND
TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO
ARMSTRONG FISSURE.
A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO
ARMSTRONG CLEAN ROOM XL
ROOM IS PROVIDED WITH A 2X4 ACOUSTIC GRID CEILING AND
TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO
ARMSTRONG FISSURE.
A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO
ARMSTRONG CLEAN ROOM XL
PROVIDE PENETRATION FOR NEW FIRE SPRINKLER RISER. REFER
TO ENGINEER DRAWINGS FOR ADDITIONAL INFORMATION.
1.
1a.
2.
2a.
3.
FLOOR PLAN KEYED NOTES X
0 16' 32'
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CLEMENT J. ZABLOCKI VAMC
#6 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
COR : MATTHEW OSGOOD 695-16-112
FIRE SPRINKLER ENGINEER
RTM CONSULTANTS, INC
6640 Parkdale Place, Suite J, Indianapolis, IN 46254
PHONE: (317) 329-7700
1220 N. PENNYSYLVANIA ST. SUITE 200 INDIANAPOLIS, IN. 46202
317.800.6388 WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
MILWAUKEE, WISCONSIN
C U s e rs
\j g o o d e n \D o c u m e n ts
\1 .1
.0
B ld g .S p ri n k le r R e p la c e m e n t -1
-1 v jg o o d e n g u id o n d e s ig n .c o m
.r v t
BID DOCUMENTS
GC101
KNLL
BASEMENT FLOOR LEVEL 0 FLOOR PLAN
2019/04/24
14.1020.06
BUILDING 6 FIRE
SPRINKLER REPLACEMENT
SCALE: 1/16" = 1'-0"GC101
1 BASEMENT FLOOR 0
N
OPEN
C
D
E
F
I
G
1 3 4
5 76
2 8 9 10
11 12 13
H
A
B
LEAN TRAINING CENTER
RM A116
RM A104
FILES/
SCANNING
RM A115
CONFERENCE
RM A114
NON-VA
RM A108A
MECHANICAL
RM
A118
SCANNING
RM A113
RM A112 RM A109
HAC
MEN'S
RM
B113
WOMEN'S
RM
B112
FEE SERVICES (MIS)
RM B110
RM B108 RM B109
RM B103
VENDING
RM
C114
LACTATION
RM C115
RM C103
RM C104
RM C105
RM C106
RM C109
RM C108
RM C107
RM C112
CEMETERY
SCHEDULING OFFICE
C113
HAC
HAC
HAC
HAC
WOMEN'S
RM D105
MEN'S
RM D105
KITCHENETTE
D103
HOME BASED PRIMARY CARE
RM D101
ROOM
A123
ROOM
A124
ROOM
A121
VFW 01VFW 02VFW 03
VFW 04VFW 05
VFW 06
VFW 07
VFW
08B VFW 09 VFW 10
VFW 11
VFW 12
RM D102
RM C104
RM
A117
WOMEN'S RM
A119
MEN'S
RM
A120
ROOM
A122
FEE SERVICES (MIS)
B111
STAIR
A
STAIR
B
STAIR
C2
STAIR
C1
STAIR
D
ELEVATOR
A
CORRIDOR
A /B
WOMEN'S
RM
B112A
ELEVATOR C2
VFW
08A
RM C115
ELEVATOR
C1
CORRIDOR C / D
WOMEN'S
RM D105A
2a
2a
2a 2a
2a
2 2
2a 2a
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
164' TRAVEL DISTANCE
2a
2 X 2 CEILING
NO CEILING
2 X 2 CEILING
2 X 2 CEILING2 X 2 CEILING
WOOD
2 X2 CEILING
2 X 2 CEILING
2 X 2 CEILING
2 X 2 CEILING
2 X 2 CEILING
METAL CEILING
METAL CEILING
BUILDING 6
WING A
BUILDING 6
WING B
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
BUILDING 6
WING A
BUILDING 6
WING B
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
LIFE SAFETY LEGEND
1 HR HAZARD AREA & 1 HR SMOKE BARRIER
2HR EXIST. SHAFT WALL & 2 HR BUILDING
SEPARATION
TRAVEL DISTANCE
EXIT EGRESS EXIT
THE BUILDING OCCUPANCY, OCCUPANCY LOAD, MEANS OF EGRESS AND FIRE
EXTINIGUSHER LOCATIONS ARE NOT BEING MODIFIED WITHIN THIS PROJECT.
THE PROJECT SCOPE OF WORK DOES NOT ANTICIPATE DISRUPTION
OF EXISTING HAZARDOUS MATERIALS. IF EXISTING PIPING INSULATION
ON PIPES AROUND SPRINKLER PIPING IS EXPOSED DURING
CONSTRUCTION NOTIFY COR AND REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
LEAD PAINT IS WITHIN THE BUILDING, THE PROJECT SCOPE
ANTICIPATED MINIMAL DISRUPTION OF THE EXISTING LEAD PAINT.
CONTRACTOR TO NOTIFY COR IF EXISTING PAINT SURFACE IS TO BE
BROKEN, CHIPPED, OR MODIFIED IN ANY WAY. REFER TO
SPECIFICATION FOR ADDITIONAL INFORMATION.
NO ASBESTOS PIPING INSULATION OR DI-ELECTIC UNIONS ARE
ANTICIPATED TO BE REMOVED WITHIN THE PROJECT SCOPE.
1.
2.
3.
HAZARDOUS MATERIAL GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
FLOOR PLAN GENERAL NOTES
BUILDING 6 IS A NATIONAL REGISTERED HISTORIC BUILDING. REF. NO.
70920.
CEILINGS ARE OPEN TO PLASTER CEILINGS THROUGH OUT PROJECT
SCOPE UNLESS OTHERWISE IDENTIFIED, REFER TO FLOOR PLANS FOR
ACOUSTIC PANEL CEILING LOCATIONS AND TYPE.
PLASTER CEILINGS SHALL BE PATCHED, PREPPED AND NEW PAINT
FINISH APPLIED TO MATCH EXISTING WHERE FIRE SPRINKLER
PROTECTION REPLACEMENT HAS CAUSED DAMAGE. PAINT CEILING
WITHIN ROOM BOUNDRY.
WHERE ACOUSTIC PANEL CEILING REMOVED IN ORDER TO COMPLETE
ABOVE CEILING WORK SHALL BE STORED IN A SAFE DRY LOCATION
SUCH AS THE CONTRACTOR PROVIDED JOB TRAILER.
DAMAGED OR BROKEN CEILING TILES SHALL BE REPLACED TO MATCH
EXISTING. REFER TO FLOOR PLANS FOR ACOUSTIC PANEL CEILING
LOCATIONS AND TYPE.
CEILING TILES WITH PENETRATIONS TO ACCOMMODATE ORIGINAL
FIRE SPRINKLER SYSTEM HEADS SHALL BE REPLACED WITH NEW
ACOUSTIC PANEL CEILING PADS.
AT THROUGHFLOOR PENETRATIONS CREATED FROM REMOVED
PIPING PROVIDE METAL PLATE ON UNDERSIDE OF FLOOR SLAB
WHERE CONCRETE INFILL IS REQUIRED. CHIP AWAY CONCRETE AT
FLOOR LEVEL TO CREATE A SLOPED OPENING/LIP TO PATCH
PENETRATIONS AND PREVENT CONCRETE INFILL CORE FROM FALLING
THROUGH OPENING TO FLOOR BELOW.
PATCH AND PREP AREA OF WALLS AND CEILING WHERE PIPING IS
REMOVED AT THROUGHWALL PENETRATIONS AND IS NOT REPLACED.
PATCH SHALL MATCH WALL CONSTRUCTION. PROVIDE PAINT TO
MATCH EXISTING AND WALL SHALL BE PAINTED FROM FLOOR TO
CEILING AND CORNER TO CORNER.
EXISTING FURNITURE AND EQUIPMENT SHALL BE COVERED AND
PROTECTED WITHIN AREAS OF WORK BEING COMPLETED. PROJECT
AREA SHALL BE PROFESSIONALLY CLEANED AND READY FOR OWNER
OCCUPANCY BY 5:00 AM.
PROVIDE CORE DRILLED PENETRATIONS THROUGH THE STAIRWAYS
AS REQUIRED BY THE SPRINKLER SHOP DRAWINGS FOR NEW RISER
AND DRAIN LINES. A TOTAL OF 4 STAIRWAY. REFER TO FLOOR PLAN
NOTES AND FIRE SPRINKLER ENGINEERING DRAWINGS FOR
ADDITIONAL INFORMATION.
FIRE SPRINKLER PIPE SHALL BE CONCEALED IN LOCATIONS WITH
ACOUSTIC PANEL CEILINGS.
FIRE SPRINKLER PIPE SHALL BE PAINTED RED PER SPECIFICATIONS IN
LOCATIONS WITH OPEN PLASTER CEILINGS.
FIRE SPRINKLER DESIGN HAS BEEN DESIGNED IN A WAY TO UTILIZE
EXISTING WALL AND FLOOR PENETRATIONS. IF A NEW PERPETRATION
IS REQUIRED LEAD, ASBESTOS TESTING AND ABATEMENTS SHALL BE
PROVIDED BY CONTRACTOR. ASSUME 24 PENETRATIONS REQUIRED, 2
PER FLOOR PER WING.
PROVIDE PLASTIC DUSTWALL CONSTRUCTION AT OPENINGS AND
TAPE DOORS TO SEAL PROJECT AREAS AT THE START OF WORK
EACH EVENING AND REMOVE AND UNSEAL EACH MORNING. REFER TO
IC SPECIFICATION FOR ADDITIONAL INFORMATION.
COVER EQUIPMENT AND OFFICE FURNITURE AT THE START OF WORK
SHIFT AND UNCOVER AT THE END. EQUIPMENT AND FURNITURE TO
REMAIN WHERE IT IS. RELOCATION TO BE REIVEWED WITH COR TWO
WEEKS PRIOR FOR NEED OF RELOCATION FOR APPROVAL.
ROOM IS PROVIDED WITH A 2X2 ACOUSTIC GRID CEILING AND
TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO
ARMSTRONG FISSURE.
A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO
ARMSTRONG CLEAN ROOM XL
ROOM IS PROVIDED WITH A 2X4 ACOUSTIC GRID CEILING AND
TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO
ARMSTRONG FISSURE.
A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO
ARMSTRONG CLEAN ROOM XL
PROVIDE PENETRATION FOR NEW FIRE SPRINKLER RISER. REFER
TO ENGINEER DRAWINGS FOR ADDITIONAL INFORMATION.
1.
1a.
2.
2a.
3.
FLOOR PLAN KEYED NOTES X
0 16' 32'
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CLEMENT J. ZABLOCKI VAMC
#6 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
COR : MATTHEW OSGOOD 695-16-112
FIRE SPRINKLER ENGINEER
RTM CONSULTANTS, INC
6640 Parkdale Place, Suite J, Indianapolis, IN 46254
PHONE: (317) 329-7700
1220 N. PENNYSYLVANIA ST. SUITE 200 INDIANAPOLIS, IN. 46202
317.800.6388 WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
MILWAUKEE, WISCONSIN
C U s e rs
\j g o o d e n \D o c u m e n ts
\1 .1
.0
B ld g .S p ri n k le r R e p la c e m e n t -1
-1 v jg o o d e n g u id o n d e s ig n .c o m
.r v t
BID DOCUMENTS
GC102
KNLL
FLOOR LEVEL 1 FLOOR PLAN
2019/04/24
14.1020.06
BUILDING 6 FIRE
SPRINKLER REPLACEMENT
SCALE: 1/16" = 1'-0"GC102
1 FLOOR 1
C
D
E
F
I
G
1 3 4
5 76
2 8 9 10
11 12 13
H
A
B
RM A209
RM A206
RM A206A
RM 205A
RM
A204
MEN'S
RM
A218
WOMEN'S
RM
A219
RM A222
RM A224
RM
A220
RM A223
RM A225
RM A229
RM A232
RM A230
RM A228
RM A227
RM A233
MECHANICAL
RM A226
MEN'S
RM
B212
WOMEN'S
RM B211
HAC
HAC HAC
RM C232
RM C231
RM
C230
VACO
RM
C229
RMC228
RM
C227
RM
C221
RM C224
RM C225
RM C226
RM
C215
RM
C214
VISN
PROSTH
RM
C2313
RM
C217C216
RM
B215
RM
B208
RM
B207
RM
B209
MIS RM
B206
RM
C202
RM
C203
RM
C204
RM
C205
RM
C207
RM
C208
RM
C209
RM
C201
RM
C212
WOMEN'S
RM D211A
RM D203
RM
D206
RM
D208
RM
D205
CONFERENCE
ROOM
RM A231
RM A211
RM A212
RM
C220
MEN'S
D210
RM
D202
RM D201B
RM
D204
RM
D207
RM
B210
RM A234
RM A213
ELEVATOR
A
STAIR
A
STAIR
B
STAIR
C2
STAIR
C1
STAIR
D
RM A211A
RM A213A
CORRIDOR A / B
RM A235
RM B211A
RM C220A
CORRIDOR
C / D
WOMEN'S
RM D211
MEN'S
D210A
RM D201
RM
D201A
2a
2a
2a 2a
2 2
2a 2a
2 2
EXIT
EXIT
EXIT
EXIT
EXIT
2 X 2 CEILING
2 X 2 CEILING
NO CEILING
2 X 2 CEILING
2 X 2 CEILING
2 X 2 CEILING
NO CEILING
GYPSUM BOARD CEILING
GYPSUM BOARD CEILING
BUILDING 6
WING A
BUILDING 6
WING B
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
BUILDING 6
WING A
BUILDING 6
WING B
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
LIFE SAFETY LEGEND
1 HR HAZARD AREA & 1 HR SMOKE BARRIER
2HR EXIST. SHAFT WALL & 2 HR BUILDING
SEPARATION
TRAVEL DISTANCE
EXIT EGRESS EXIT
THE BUILDING OCCUPANCY, OCCUPANCY LOAD, MEANS OF EGRESS AND FIRE
EXTINIGUSHER LOCATIONS ARE NOT BEING MODIFIED WITHIN THIS PROJECT.
THE PROJECT SCOPE OF WORK DOES NOT ANTICIPATE DISRUPTION
OF EXISTING HAZARDOUS MATERIALS. IF EXISTING PIPING INSULATION
ON PIPES AROUND SPRINKLER PIPING IS EXPOSED DURING
CONSTRUCTION NOTIFY COR AND REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
LEAD PAINT IS WITHIN THE BUILDING, THE PROJECT SCOPE
ANTICIPATED MINIMAL DISRUPTION OF THE EXISTING LEAD PAINT.
CONTRACTOR TO NOTIFY COR IF EXISTING PAINT SURFACE IS TO BE
BROKEN, CHIPPED, OR MODIFIED IN ANY WAY. REFER TO
SPECIFICATION FOR ADDITIONAL INFORMATION.
NO ASBESTOS PIPING INSULATION OR DI-ELECTIC UNIONS ARE
ANTICIPATED TO BE REMOVED WITHIN THE PROJECT SCOPE.
1.
2.
3.
HAZARDOUS MATERIAL GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
FLOOR PLAN GENERAL NOTES
BUILDING 6 IS A NATIONAL REGISTERED HISTORIC BUILDING. REF. NO.
70920.
CEILINGS ARE OPEN TO PLASTER CEILINGS THROUGH OUT PROJECT
SCOPE UNLESS OTHERWISE IDENTIFIED, REFER TO FLOOR PLANS FOR
ACOUSTIC PANEL CEILING LOCATIONS AND TYPE.
PLASTER CEILINGS SHALL BE PATCHED, PREPPED AND NEW PAINT
FINISH APPLIED TO MATCH EXISTING WHERE FIRE SPRINKLER
PROTECTION REPLACEMENT HAS CAUSED DAMAGE. PAINT CEILING
WITHIN ROOM BOUNDRY.
WHERE ACOUSTIC PANEL CEILING REMOVED IN ORDER TO COMPLETE
ABOVE CEILING WORK SHALL BE STORED IN A SAFE DRY LOCATION
SUCH AS THE CONTRACTOR PROVIDED JOB TRAILER.
DAMAGED OR BROKEN CEILING TILES SHALL BE REPLACED TO MATCH
EXISTING. REFER TO FLOOR PLANS FOR ACOUSTIC PANEL CEILING
LOCATIONS AND TYPE.
CEILING TILES WITH PENETRATIONS TO ACCOMMODATE ORIGINAL
FIRE SPRINKLER SYSTEM HEADS SHALL BE REPLACED WITH NEW
ACOUSTIC PANEL CEILING PADS.
AT THROUGHFLOOR PENETRATIONS CREATED FROM REMOVED
PIPING PROVIDE METAL PLATE ON UNDERSIDE OF FLOOR SLAB
WHERE CONCRETE INFILL IS REQUIRED. CHIP AWAY CONCRETE AT
FLOOR LEVEL TO CREATE A SLOPED OPENING/LIP TO PATCH
PENETRATIONS AND PREVENT CONCRETE INFILL CORE FROM FALLING
THROUGH OPENING TO FLOOR BELOW.
PATCH AND PREP AREA OF WALLS AND CEILING WHERE PIPING IS
REMOVED AT THROUGHWALL PENETRATIONS AND IS NOT REPLACED.
PATCH SHALL MATCH WALL CONSTRUCTION. PROVIDE PAINT TO
MATCH EXISTING AND WALL SHALL BE PAINTED FROM FLOOR TO
CEILING AND CORNER TO CORNER.
EXISTING FURNITURE AND EQUIPMENT SHALL BE COVERED AND
PROTECTED WITHIN AREAS OF WORK BEING COMPLETED. PROJECT
AREA SHALL BE PROFESSIONALLY CLEANED AND READY FOR OWNER
OCCUPANCY BY 5:00 AM.
PROVIDE CORE DRILLED PENETRATIONS THROUGH THE STAIRWAYS
AS REQUIRED BY THE SPRINKLER SHOP DRAWINGS FOR NEW RISER
AND DRAIN LINES. A TOTAL OF 4 STAIRWAY. REFER TO FLOOR PLAN
NOTES AND FIRE SPRINKLER ENGINEERING DRAWINGS FOR
ADDITIONAL INFORMATION.
FIRE SPRINKLER PIPE SHALL BE CONCEALED IN LOCATIONS WITH
ACOUSTIC PANEL CEILINGS.
FIRE SPRINKLER PIPE SHALL BE PAINTED RED PER SPECIFICATIONS IN
LOCATIONS WITH OPEN PLASTER CEILINGS.
FIRE SPRINKLER DESIGN HAS BEEN DESIGNED IN A WAY TO UTILIZE
EXISTING WALL AND FLOOR PENETRATIONS. IF A NEW PERPETRATION
IS REQUIRED LEAD, ASBESTOS TESTING AND ABATEMENTS SHALL BE
PROVIDED BY CONTRACTOR. ASSUME 24 PENETRATIONS REQUIRED, 2
PER FLOOR PER WING.
PROVIDE PLASTIC DUSTWALL CONSTRUCTION AT OPENINGS AND
TAPE DOORS TO SEAL PROJECT AREAS AT THE START OF WORK
EACH EVENING AND REMOVE AND UNSEAL EACH MORNING. REFER TO
IC SPECIFICATION FOR ADDITIONAL INFORMATION.
COVER EQUIPMENT AND OFFICE FURNITURE AT THE START OF WORK
SHIFT AND UNCOVER AT THE END. EQUIPMENT AND FURNITURE TO
REMAIN WHERE IT IS. RELOCATION TO BE REIVEWED WITH COR TWO
WEEKS PRIOR FOR NEED OF RELOCATION FOR APPROVAL.
ROOM IS PROVIDED WITH A 2X2 ACOUSTIC GRID CEILING AND
TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO
ARMSTRONG FISSURE.
A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO
ARMSTRONG CLEAN ROOM XL
ROOM IS PROVIDED WITH A 2X4 ACOUSTIC GRID CEILING AND
TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO
ARMSTRONG FISSURE.
A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO
ARMSTRONG CLEAN ROOM XL
PROVIDE PENETRATION FOR NEW FIRE SPRINKLER RISER. REFER
TO ENGINEER DRAWINGS FOR ADDITIONAL INFORMATION.
1.
1a.
2.
2a.
3.
FLOOR PLAN KEYED NOTES X
0 16' 32'
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CLEMENT J. ZABLOCKI VAMC
#6 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
COR : MATTHEW OSGOOD 695-16-112
FIRE SPRINKLER ENGINEER
RTM CONSULTANTS, INC
6640 Parkdale Place, Suite J, Indianapolis, IN 46254
PHONE: (317) 329-7700
1220 N. PENNYSYLVANIA ST. SUITE 200 INDIANAPOLIS, IN. 46202
317.800.6388 WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
MILWAUKEE, WISCONSIN
C U s e rs
\j g o o d e n \D o c u m e n ts
\1 .1
.0
B ld g .S p ri n k le r R e p la c e m e n t -1
-1 v jg o o d e n g u id o n d e s ig n .c o m
.r v t
BID DOCUMENTS
GC103
KNLL
FLOOR LEVEL 2 FLOOR PLAN
2019/04/24
14.1020.06
BUILDING 6 FIRE
SPRINKLER REPLACEMENT
SCALE: 1/16" = 1'-0"GC103
1 FLOOR 2
OPEN
FLAT
ROOF
OPEN
FLAT
ROOF
OPEN
FLAT
ROOF
OPEN
FLAT
ROOF
OPEN
FLAT
ROOF
OPEN
FLAT
ROOF
OPEN
FLAT
ROOF
OPEN
FLAT
ROOF
ATTIC
WING
A
ATTIC
WING
B
ATTIC
WING
C1
ATTIC
WING
C2
ATTIC
WING
D
ATTIC
WING
C3
A
B
C
D
E
F
I
G
1 3 4
5 76
2 8 9 10
11 12 13
H
SLOPE
10'-6"+/-
AT PEAK OF ATTIC
SLOPE
A
B
C
DN
E
F
8 9 10
BUILDING 6
WING A
BUILDING 6
WING B
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
BUILDING 6
WING A
BUILDING 6
WING B
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
RM C304
RM C305 RM C307
RM C303
RM C302
RM C306 RM C308
RM C301
STAIR
C1
CORR.
C3A
ELE.
C
2a1
EXIT
2 X 2 CEILING
BUILDING 6
WING B
BUILDING 6
WING C
BUILDING
6 WING C
BUILDING
6 WING D
LIFE SAFETY LEGEND
1 HR HAZARD AREA & 1 HR SMOKE BARRIER
2HR EXIST. SHAFT WALL & 2 HR BUILDING
SEPARATION
TRAVEL DISTANCE
EXIT EGRESS EXIT
THE BUILDING OCCUPANCY, OCCUPANCY LOAD, MEANS OF…