About this file

36C25219B0056 0003 S06 - GC104 - FLOOR LEVEL 3 AND ATTIC LEVEL FLOOR PLAN.pdf

View the file

Other files

File Type Posted
36C25219C0222-000.docx DOCX document
36C25219B0056-0005000.docx DOCX document
36C25219B0056-0004002.pdf PDF
36C25219B0056-0004000.docx DOCX document
36C25219B0056-0004001.pdf PDF
36C25219B0056-0003007.pdf PDF
36C25219B0056-0003008.pdf PDF
36C25219B0056-0003001.pdf PDF
36C25219B0056-0003003.pdf PDF
36C25219B0056-0003004.pdf PDF
36C25219B0056-0003005.pdf PDF
36C25219B0056-0003020.pdf PDF
36C25219B0056-0003015.pdf PDF
36C25219B0056-0003013.pdf PDF
36C25219B0056-0003019.pdf PDF
36C25219B0056-0003006.pdf PDF
36C25219B0056-0003012.pdf PDF
36C25219B0056-0003017.pdf PDF
36C25219B0056-0003016.pdf PDF
36C25219B0056-0003011.pdf PDF
36C25219B0056-0003009.pdf PDF
36C25219B0056-0003010.pdf PDF
36C25219B0056-0003018.pdf PDF
36C25219B0056-0003002.pdf PDF
36C25219B0056-0003000.docx DOCX document
36C25219B0056-0002001.pdf PDF
36C25219B0056-0002000.docx DOCX document
36C25219B0056-0002002.pdf PDF
36C25219B0056-0001000.docx DOCX document
36C25219B0056-001.docx DOCX document
36C25219B0056-002.pdf PDF
36C25219B0056-005.pdf PDF
36C25219B0056-004.pdf PDF
36C25219B0056-003.pdf PDF
36C25219B0056-006.pdf PDF
36C25219B0056-000.docx DOCX document
36C25219B0056-000.docx DOCX document
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OPEN

FLAT

ROOF

OPEN

FLAT

ROOF

OPEN

FLAT

ROOF

OPEN

FLAT

ROOF

OPEN

FLAT

ROOF

OPEN

FLAT

ROOF

OPEN

FLAT

ROOF

OPEN

FLAT

ROOF

ATTIC

WING

A

ATTIC

WING

B

ATTIC

WING

C1

ATTIC

WING

C2

ATTIC

WING

D

ATTIC

WING

C3

A

B

C

D

E

F

I

G

1 3 4

5 76

2 8 9 10

11 12 13

H

SLOPE

10'-6"+/-

AT PEAK OF ATTIC

SLOPE

A

B

C

DN

E

F

8 9 10

BUILDING 6

WING A

BUILDING 6

WING B

BUILDING 6

WING B

BUILDING 6

WING C

BUILDING

6 WING C

BUILDING

6 WING D

BUILDING 6

WING A

BUILDING 6

WING B

BUILDING 6

WING B

BUILDING 6

WING C

BUILDING

6 WING C

BUILDING

6 WING D

RM C304

RM C305 RM C307

RM C303

RM C302

RM C306 RM C308

RM C301

STAIR

C1

CORR.

C3A

ELE.

C

2a1

EXIT

2 X 2 CEILING

BUILDING 6

WING B

BUILDING 6

WING C

BUILDING

6 WING C

BUILDING

6 WING D

LIFE SAFETY LEGEND

1 HR HAZARD AREA & 1 HR SMOKE BARRIER

2HR EXIST. SHAFT WALL & 2 HR BUILDING

SEPARATION

TRAVEL DISTANCE

EXIT EGRESS EXIT

THE BUILDING OCCUPANCY, OCCUPANCY LOAD, MEANS OF EGRESS AND FIRE

EXTINIGUSHER LOCATIONS ARE NOT BEING MODIFIED WITHIN THIS PROJECT.

THE PROJECT SCOPE OF WORK DOES NOT ANTICIPATE DISRUPTION

OF EXISTING HAZARDOUS MATERIALS. IF EXISTING PIPING INSULATION

ON PIPES AROUND SPRINKLER PIPING IS EXPOSED DURING

CONSTRUCTION NOTIFY COR AND REFER TO SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

LEAD PAINT IS WITHIN THE BUILDING, THE PROJECT SCOPE

ANTICIPATED MINIMAL DISRUPTION OF THE EXISTING LEAD PAINT.

CONTRACTOR TO NOTIFY COR IF EXISTING PAINT SURFACE IS TO BE

BROKEN, CHIPPED, OR MODIFIED IN ANY WAY. REFER TO

SPECIFICATION FOR ADDITIONAL INFORMATION.

NO ASBESTOS PIPING INSULATION OR DI-ELECTIC UNIONS ARE

ANTICIPATED TO BE REMOVED WITHIN THE PROJECT SCOPE.

1.

2.

3.

HAZARDOUS MATERIAL GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

FLOOR PLAN GENERAL NOTES

BUILDING 6 IS A NATIONAL REGISTERED HISTORIC BUILDING. REF. NO.

70920.

CEILINGS ARE OPEN TO PLASTER CEILINGS THROUGH OUT PROJECT

SCOPE UNLESS OTHERWISE IDENTIFIED, REFER TO FLOOR PLANS FOR

ACOUSTIC PANEL CEILING LOCATIONS AND TYPE.

PLASTER CEILINGS SHALL BE PATCHED, PREPPED AND NEW PAINT

FINISH APPLIED TO MATCH EXISTING WHERE FIRE SPRINKLER

PROTECTION REPLACEMENT HAS CAUSED DAMAGE. PAINT CEILING

WITHIN ROOM BOUNDRY.

WHERE ACOUSTIC PANEL CEILING REMOVED IN ORDER TO COMPLETE

ABOVE CEILING WORK SHALL BE STORED IN A SAFE DRY LOCATION

SUCH AS THE CONTRACTOR PROVIDED JOB TRAILER.

DAMAGED OR BROKEN CEILING TILES SHALL BE REPLACED TO MATCH

EXISTING. REFER TO FLOOR PLANS FOR ACOUSTIC PANEL CEILING

LOCATIONS AND TYPE.

CEILING TILES WITH PENETRATIONS TO ACCOMMODATE ORIGINAL

FIRE SPRINKLER SYSTEM HEADS SHALL BE REPLACED WITH NEW

ACOUSTIC PANEL CEILING PADS.

AT THROUGHFLOOR PENETRATIONS CREATED FROM REMOVED

PIPING PROVIDE METAL PLATE ON UNDERSIDE OF FLOOR SLAB

WHERE CONCRETE INFILL IS REQUIRED. CHIP AWAY CONCRETE AT

FLOOR LEVEL TO CREATE A SLOPED OPENING/LIP TO PATCH

PENETRATIONS AND PREVENT CONCRETE INFILL CORE FROM FALLING

THROUGH OPENING TO FLOOR BELOW.

PATCH AND PREP AREA OF WALLS AND CEILING WHERE PIPING IS

REMOVED AT THROUGHWALL PENETRATIONS AND IS NOT REPLACED.

PATCH SHALL MATCH WALL CONSTRUCTION. PROVIDE PAINT TO

MATCH EXISTING AND WALL SHALL BE PAINTED FROM FLOOR TO

CEILING AND CORNER TO CORNER.

EXISTING FURNITURE AND EQUIPMENT SHALL BE COVERED AND

PROTECTED WITHIN AREAS OF WORK BEING COMPLETED. PROJECT

AREA SHALL BE PROFESSIONALLY CLEANED AND READY FOR OWNER

OCCUPANCY BY 5:00 AM.

PROVIDE CORE DRILLED PENETRATIONS THROUGH THE STAIRWAYS

AS REQUIRED BY THE SPRINKLER SHOP DRAWINGS FOR NEW RISER

AND DRAIN LINES. A TOTAL OF 4 STAIRWAY. REFER TO FLOOR PLAN

NOTES AND FIRE SPRINKLER ENGINEERING DRAWINGS FOR

ADDITIONAL INFORMATION.

FIRE SPRINKLER PIPE SHALL BE CONCEALED IN LOCATIONS WITH

ACOUSTIC PANEL CEILINGS.

FIRE SPRINKLER PIPE SHALL BE PAINTED RED PER SPECIFICATIONS IN

LOCATIONS WITH OPEN PLASTER CEILINGS.

FIRE SPRINKLER DESIGN HAS BEEN DESIGNED IN A WAY TO UTILIZE

EXISTING WALL AND FLOOR PENETRATIONS. IF A NEW PERPETRATION

IS REQUIRED LEAD, ASBESTOS TESTING AND ABATEMENTS SHALL BE

PROVIDED BY CONTRACTOR. ASSUME 24 PENETRATIONS REQUIRED, 2

PER FLOOR PER WING.

PROVIDE PLASTIC DUSTWALL CONSTRUCTION AT OPENINGS AND

TAPE DOORS TO SEAL PROJECT AREAS AT THE START OF WORK

EACH EVENING AND REMOVE AND UNSEAL EACH MORNING. REFER TO

IC SPECIFICATION FOR ADDITIONAL INFORMATION.

COVER EQUIPMENT AND OFFICE FURNITURE AT THE START OF WORK

SHIFT AND UNCOVER AT THE END. EQUIPMENT AND FURNITURE TO

REMAIN WHERE IT IS. RELOCATION TO BE REIVEWED WITH COR TWO

WEEKS PRIOR FOR NEED OF RELOCATION FOR APPROVAL.

ROOM IS PROVIDED WITH A 2X2 ACOUSTIC GRID CEILING AND

TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO

ARMSTRONG FISSURE.

A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO

ARMSTRONG CLEAN ROOM XL

ROOM IS PROVIDED WITH A 2X4 ACOUSTIC GRID CEILING AND

TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO

ARMSTRONG FISSURE.

A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO

ARMSTRONG CLEAN ROOM XL

PROVIDE PENETRATION FOR NEW FIRE SPRINKLER RISER. REFER

TO ENGINEER DRAWINGS FOR ADDITIONAL INFORMATION.

1.

1a.

2.

2a.

3.

FLOOR PLAN KEYED NOTES X

RM C310

RM C311

RM C312

RM C313

RM

C315

STAIR

C2

RM C314

RM

C316

CORR.

C3B

CORR. C3C

EXIT

96'

TRAVEL

DISTANCE

PLASTER

NO CEILING

BUILDING

6 WING B

BUILDING

6 WING C

BUILDING

6 WING C

BUILDING

6 WING D

0 16' 32'

0 16' 32'

0 16' 32'

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CLEMENT J. ZABLOCKI VAMC

#6 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

COR : MATTHEW OSGOOD 695-16-112

FIRE SPRINKLER ENGINEER

RTM CONSULTANTS, INC

6640 Parkdale Place, Suite J, Indianapolis, IN 46254

PHONE: (317) 329-7700

1220 N. PENNYSYLVANIA ST. SUITE 200 INDIANAPOLIS, IN. 46202

317.800.6388 WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

CLEMENT J. ZABLOCKI VA MEDICAL CENTER

MILWAUKEE, WISCONSIN

C U s e rs

\j g o o d e n \D o c u m e n ts

\1 .1

.0

B ld g .S p ri n k le r R e p la c e m e n t -1

-1 v jg o o d e n g u id o n d e s ig n .c o m

.r v t

BID DOCUMENTS

GC104

KNLL

FLOOR LEVEL 3 AND ATTIC LEVEL

FLOOR PLAN

2019/04/24

14.1020.06

BUILDING 6 FIRE

SPRINKLER REPLACEMENT

SCALE: 1/16" = 1'-0"GC104

3 ATTIC PLAN

SCALE: 1/16" = 1'-0"GC104

1 THIRD FLOOR SOUTH / WING C1 PLAN

N

SCALE: 1/16" = 1'-0"GC104

2 THIRD FLOOR SOUTH / WING C2 PLAN

N

N

ACCOMPANYING 36C25219B0056 0003

File details come from the government source that posted it.