About this file

36C25219B0056 0003 S06 - GC102 - FLOOR LEVEL 1 FLOOR PLAN.pdf

View the file

Other files

File Type Posted
36C25219C0222-000.docx DOCX document
36C25219B0056-0005000.docx DOCX document
36C25219B0056-0004002.pdf PDF
36C25219B0056-0004000.docx DOCX document
36C25219B0056-0004001.pdf PDF
36C25219B0056-0003007.pdf PDF
36C25219B0056-0003008.pdf PDF
36C25219B0056-0003001.pdf PDF
36C25219B0056-0003003.pdf PDF
36C25219B0056-0003004.pdf PDF
36C25219B0056-0003005.pdf PDF
36C25219B0056-0003020.pdf PDF
36C25219B0056-0003015.pdf PDF
36C25219B0056-0003013.pdf PDF
36C25219B0056-0003014.pdf PDF
36C25219B0056-0003019.pdf PDF
36C25219B0056-0003006.pdf PDF
36C25219B0056-0003017.pdf PDF
36C25219B0056-0003016.pdf PDF
36C25219B0056-0003011.pdf PDF
36C25219B0056-0003009.pdf PDF
36C25219B0056-0003010.pdf PDF
36C25219B0056-0003018.pdf PDF
36C25219B0056-0003002.pdf PDF
36C25219B0056-0003000.docx DOCX document
36C25219B0056-0002001.pdf PDF
36C25219B0056-0002000.docx DOCX document
36C25219B0056-0002002.pdf PDF
36C25219B0056-0001000.docx DOCX document
36C25219B0056-001.docx DOCX document
36C25219B0056-002.pdf PDF
36C25219B0056-005.pdf PDF
36C25219B0056-004.pdf PDF
36C25219B0056-003.pdf PDF
36C25219B0056-006.pdf PDF
36C25219B0056-000.docx DOCX document
36C25219B0056-000.docx DOCX document
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C

D

E

F

I

G

1 3 4

5 76

2 8 9 10

11 12 13

H

A

B

LEAN TRAINING CENTER

RM A116

RM A104

FILES/

SCANNING

RM A115

CONFERENCE

RM A114

NON-VA

RM A108A

MECHANICAL

RM

A118

SCANNING

RM A113

RM A112 RM A109

HAC

MEN'S

RM

B113

WOMEN'S

RM

B112

FEE SERVICES (MIS)

RM B110

RM B108 RM B109

RM B103

VENDING

RM

C114

LACTATION

RM C115

RM C103

RM C104

RM C105

RM C106

RM C109

RM C108

RM C107

RM C112

CEMETERY

SCHEDULING OFFICE

C113

HAC

HAC

HAC

HAC

WOMEN'S

RM D105

MEN'S

RM D105

KITCHENETTE

D103

HOME BASED PRIMARY CARE

RM D101

ROOM

A123

ROOM

A124

ROOM

A121

VFW 01VFW 02VFW 03

VFW 04VFW 05

VFW 06

VFW 07

VFW

08B VFW 09 VFW 10

VFW 11

VFW 12

RM D102

RM C104

RM

A117

WOMEN'S RM

A119

MEN'S

RM

A120

ROOM

A122

FEE SERVICES (MIS)

B111

STAIR

A

STAIR

B

STAIR

C2

STAIR

C1

STAIR

D

ELEVATOR

A

CORRIDOR

A /B

WOMEN'S

RM

B112A

ELEVATOR C2

VFW

08A

RM C115

ELEVATOR

C1

CORRIDOR C / D

WOMEN'S

RM D105A

2a

2a

2a 2a

2a

2 2

2a 2a

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

164' TRAVEL DISTANCE

2a

2 X 2 CEILING

NO CEILING

2 X 2 CEILING

2 X 2 CEILING2 X 2 CEILING

WOOD

2 X2 CEILING

2 X 2 CEILING

2 X 2 CEILING

2 X 2 CEILING

2 X 2 CEILING

METAL CEILING

METAL CEILING

BUILDING 6

WING A

BUILDING 6

WING B

BUILDING 6

WING B

BUILDING 6

WING C

BUILDING

6 WING C

BUILDING

6 WING D

BUILDING 6

WING A

BUILDING 6

WING B

BUILDING 6

WING B

BUILDING 6

WING C

BUILDING

6 WING C

BUILDING

6 WING D

LIFE SAFETY LEGEND

1 HR HAZARD AREA & 1 HR SMOKE BARRIER

2HR EXIST. SHAFT WALL & 2 HR BUILDING

SEPARATION

TRAVEL DISTANCE

EXIT EGRESS EXIT

THE BUILDING OCCUPANCY, OCCUPANCY LOAD, MEANS OF EGRESS AND FIRE

EXTINIGUSHER LOCATIONS ARE NOT BEING MODIFIED WITHIN THIS PROJECT.

THE PROJECT SCOPE OF WORK DOES NOT ANTICIPATE DISRUPTION

OF EXISTING HAZARDOUS MATERIALS. IF EXISTING PIPING INSULATION

ON PIPES AROUND SPRINKLER PIPING IS EXPOSED DURING

CONSTRUCTION NOTIFY COR AND REFER TO SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

LEAD PAINT IS WITHIN THE BUILDING, THE PROJECT SCOPE

ANTICIPATED MINIMAL DISRUPTION OF THE EXISTING LEAD PAINT.

CONTRACTOR TO NOTIFY COR IF EXISTING PAINT SURFACE IS TO BE

BROKEN, CHIPPED, OR MODIFIED IN ANY WAY. REFER TO

SPECIFICATION FOR ADDITIONAL INFORMATION.

NO ASBESTOS PIPING INSULATION OR DI-ELECTIC UNIONS ARE

ANTICIPATED TO BE REMOVED WITHIN THE PROJECT SCOPE.

1.

2.

3.

HAZARDOUS MATERIAL GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

FLOOR PLAN GENERAL NOTES

BUILDING 6 IS A NATIONAL REGISTERED HISTORIC BUILDING. REF. NO.

70920.

CEILINGS ARE OPEN TO PLASTER CEILINGS THROUGH OUT PROJECT

SCOPE UNLESS OTHERWISE IDENTIFIED, REFER TO FLOOR PLANS FOR

ACOUSTIC PANEL CEILING LOCATIONS AND TYPE.

PLASTER CEILINGS SHALL BE PATCHED, PREPPED AND NEW PAINT

FINISH APPLIED TO MATCH EXISTING WHERE FIRE SPRINKLER

PROTECTION REPLACEMENT HAS CAUSED DAMAGE. PAINT CEILING

WITHIN ROOM BOUNDRY.

WHERE ACOUSTIC PANEL CEILING REMOVED IN ORDER TO COMPLETE

ABOVE CEILING WORK SHALL BE STORED IN A SAFE DRY LOCATION

SUCH AS THE CONTRACTOR PROVIDED JOB TRAILER.

DAMAGED OR BROKEN CEILING TILES SHALL BE REPLACED TO MATCH

EXISTING. REFER TO FLOOR PLANS FOR ACOUSTIC PANEL CEILING

LOCATIONS AND TYPE.

CEILING TILES WITH PENETRATIONS TO ACCOMMODATE ORIGINAL

FIRE SPRINKLER SYSTEM HEADS SHALL BE REPLACED WITH NEW

ACOUSTIC PANEL CEILING PADS.

AT THROUGHFLOOR PENETRATIONS CREATED FROM REMOVED

PIPING PROVIDE METAL PLATE ON UNDERSIDE OF FLOOR SLAB

WHERE CONCRETE INFILL IS REQUIRED. CHIP AWAY CONCRETE AT

FLOOR LEVEL TO CREATE A SLOPED OPENING/LIP TO PATCH

PENETRATIONS AND PREVENT CONCRETE INFILL CORE FROM FALLING

THROUGH OPENING TO FLOOR BELOW.

PATCH AND PREP AREA OF WALLS AND CEILING WHERE PIPING IS

REMOVED AT THROUGHWALL PENETRATIONS AND IS NOT REPLACED.

PATCH SHALL MATCH WALL CONSTRUCTION. PROVIDE PAINT TO

MATCH EXISTING AND WALL SHALL BE PAINTED FROM FLOOR TO

CEILING AND CORNER TO CORNER.

EXISTING FURNITURE AND EQUIPMENT SHALL BE COVERED AND

PROTECTED WITHIN AREAS OF WORK BEING COMPLETED. PROJECT

AREA SHALL BE PROFESSIONALLY CLEANED AND READY FOR OWNER

OCCUPANCY BY 5:00 AM.

PROVIDE CORE DRILLED PENETRATIONS THROUGH THE STAIRWAYS

AS REQUIRED BY THE SPRINKLER SHOP DRAWINGS FOR NEW RISER

AND DRAIN LINES. A TOTAL OF 4 STAIRWAY. REFER TO FLOOR PLAN

NOTES AND FIRE SPRINKLER ENGINEERING DRAWINGS FOR

ADDITIONAL INFORMATION.

FIRE SPRINKLER PIPE SHALL BE CONCEALED IN LOCATIONS WITH

ACOUSTIC PANEL CEILINGS.

FIRE SPRINKLER PIPE SHALL BE PAINTED RED PER SPECIFICATIONS IN

LOCATIONS WITH OPEN PLASTER CEILINGS.

FIRE SPRINKLER DESIGN HAS BEEN DESIGNED IN A WAY TO UTILIZE

EXISTING WALL AND FLOOR PENETRATIONS. IF A NEW PERPETRATION

IS REQUIRED LEAD, ASBESTOS TESTING AND ABATEMENTS SHALL BE

PROVIDED BY CONTRACTOR. ASSUME 24 PENETRATIONS REQUIRED, 2

PER FLOOR PER WING.

PROVIDE PLASTIC DUSTWALL CONSTRUCTION AT OPENINGS AND

TAPE DOORS TO SEAL PROJECT AREAS AT THE START OF WORK

EACH EVENING AND REMOVE AND UNSEAL EACH MORNING. REFER TO

IC SPECIFICATION FOR ADDITIONAL INFORMATION.

COVER EQUIPMENT AND OFFICE FURNITURE AT THE START OF WORK

SHIFT AND UNCOVER AT THE END. EQUIPMENT AND FURNITURE TO

REMAIN WHERE IT IS. RELOCATION TO BE REIVEWED WITH COR TWO

WEEKS PRIOR FOR NEED OF RELOCATION FOR APPROVAL.

ROOM IS PROVIDED WITH A 2X2 ACOUSTIC GRID CEILING AND

TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO

ARMSTRONG FISSURE.

A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO

ARMSTRONG CLEAN ROOM XL

ROOM IS PROVIDED WITH A 2X4 ACOUSTIC GRID CEILING AND

TYPICAL OFFICE GRADE ACOUSTIC PANEL CEILING, EQUAL TO

ARMSTRONG FISSURE.

A. SMOOTH CEILING TILE IS INSTALLED, EQUAL TO

ARMSTRONG CLEAN ROOM XL

PROVIDE PENETRATION FOR NEW FIRE SPRINKLER RISER. REFER

TO ENGINEER DRAWINGS FOR ADDITIONAL INFORMATION.

1.

1a.

2.

2a.

3.

FLOOR PLAN KEYED NOTES X

0 16' 32'

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CLEMENT J. ZABLOCKI VAMC

#6 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

COR : MATTHEW OSGOOD 695-16-112

FIRE SPRINKLER ENGINEER

RTM CONSULTANTS, INC

6640 Parkdale Place, Suite J, Indianapolis, IN 46254

PHONE: (317) 329-7700

1220 N. PENNYSYLVANIA ST. SUITE 200 INDIANAPOLIS, IN. 46202

317.800.6388 WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

CLEMENT J. ZABLOCKI VA MEDICAL CENTER

MILWAUKEE, WISCONSIN

C U s e rs

\j g o o d e n \D o c u m e n ts

\1 .1

.0

B ld g .S p ri n k le r R e p la c e m e n t -1

-1 v jg o o d e n g u id o n d e s ig n .c o m

.r v t

BID DOCUMENTS

GC102

KNLL

FLOOR LEVEL 1 FLOOR PLAN

2019/04/24

14.1020.06

BUILDING 6 FIRE

SPRINKLER REPLACEMENT

SCALE: 1/16" = 1'-0"GC102

1 FLOOR 1

N

ACCOMPANYING 36C25219B0056 0003