This document is a technical specification (Section 08 34 00) for Sliding Door Opening Assemblies for the Battle Creek VA Medical Center Audiology Renovation project. The specification details requirements for aluminum-framed top-hung sliding doors, including precise technical specifications for door components, hardware, finishes, and installation. Key requirements include:
Sliding door system specifications mandate a Serenity Sliding Door System or equivalent, with specific performance characteristics such as a clear anodized aluminum track system, soft close mechanism, and sound transmission class (STC) ratings of 40-50 depending on room type. The doors will be 1-3/4" thick flush wood doors with 6" stile widths and 10" bottom rails, featuring back-to-back ladder pulls, deadlock hardware, and ADA-compliant thumbturns. The manufacturer must provide comprehensive documentation, installation training, post-installation audits, and a two-year warranty, with additional commitments to provide technical support and ensure long-term functionality of the sliding door assemblies.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bid Addendum #1 BATTLE CREEK VA MEDICAL CENTER
RENOVATE AUDIOLOGY
PROJECT NO. 515-23-101
SLIDING DOOR OPENING ASSEMBLIES
08 34 00 - 1
SECTION 08 34 00
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. Sliding door, frame, and hardware assemblies.
B. Aluminum-Framed Top-Hung Sliding Doors.
1.2 RELATED REQUIREMENTS
A. Section 08 14 16 – Flush Wood Doors: For flush solid-core wood sliding doors specified in this section used in Sliding Door System.
B. Section 08 13 16 – Aluminum Doors. For Aluminum sliding doors specified in this section.
C. Section 08 71 00 – Door Hardware.
D. Section 08 80 00 – Glazing in sliding door panels.
1.3 REFERENCE STANDARDS
A. AAMA 609 and 610 – Cleaning and Maintenance Guide for Architecturally
Finished Aluminum (Combined Document) 2015.
B. ANSI A156.18 – American National Standard for Materials and Finishes
C. ANSI A117.1 – American National Standard for Specifications to Make
Buildings and Facilities Accessible and Usable to People with Physical
Disabilities
D. AWS – Architectural Woodwork Standards
E. BHMA – Builders Hardware Manufacturers Association
F. DHI- Door and Hardware Institute
1.4 SUBMITTALS
A. Submittals shall be in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B. Product Data: Provide component dimensions, information on glass and glazing, and descriptions of hardware and accessories.
C. Shop Drawings: indicate opening dimensions, elevations of different types, framed opening tolerances, and installation requirements.
D. Manufacturer’s Certification: Certify that sliding glass doors meet or exceed expectations.
E. Manufacturer's Installation Instructions: Include complete preparation, installation, and cleaning requirements.
F. Manufacturer’s qualification statement.
G. Installer’s qualification statement.
08 34 00 - 2
H. Shop Drawings: Indicate details of each opening showing elevations, glazing, frame profiles, hardware, and different finish locations, if any.
I. Informational Submittals:
1. Provide Product Data:
i Specified door hardware must have warranties included.
ii Provide product qualification data for Sliding Doors for:
Architect, Installer, and Architectural Specification Consultant.
J. Closeout Submittals:
1. Provide Maintenance and Operations Data corresponding to Division
01.
i Provide information and data about maintenance, repairs, and adjustment for Sliding Door System, in addition to replacement parts and how to preserve finishes within 72 hours of requests.
ii Provide Complete Catalog cuts and pages for all parts of Sliding
Door System.
iii Provide parts list for each component of Sliding Door System.
iv Provide name, address, and telephone number of local representative of Sliding Door System manufacturer.
v Warranty for Sliding Door System shall include reference numbers for manufacturer and identification of project it is specified in.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with a minimum of five years documented experience.
B. Drawings provided will indicate size, dimensional requirements of interior aluminum frames/doors and profiles.
C. Installer shall be certified with product manufacturer for installation.
D. Store in accordance with manufacturer’s installation instructions to ensure warranty is kept.
1.6 WARRANTY
A. Construction Warranty: FAR clause 52.246-21, "Warranty of
Construction."
B. Provide manufacturer’s standard warranty against defects in material and workmanship:
08 34 00 - 3
1. For entire door opening assembly, provide two-year warranty period after Date of Substantial Completion.
2. Interior Flush wood door slabs: See Section 08 14 00 –
INTERIOR WOOD DOORS.
3. Assurance Program: Company specializing in manufacturing the products specified in this section shall offer technical training and project support pre and post installation.
1.7 PERFORMANCE
A. Enhanced gasket and seals integrated in all door/frame interfaces with aluminum perimeter frames. Architect will verify wall thickness required for application.
B. Commercial grade anti-slam soft close and open system with back stop reinforcement. Closers test to a minimum of 100,000 cycles.
C. Concealed Floor Guide and Wall Mount Guide
D. Acoustical performance testing provided by third party.
Manufacturer to submit test data as required.
a. Acoustic Rating: SEE PART 2.2.L. Minimum STC 35 rated sounds control assemblies tested at an independent acoustic laboratory in accordance with ASTM E90 Sealed-In-Place
Standard.
b. 3-sided perimeter seal system as part of door assembly.
E. Air infiltration and smoke ratings provided by third party.
Manufacturer to submit test data as required. Reference UL1784
Testing Data.
1.8 DELIVERY, STORAGE AND HANDLING
A. Inventory door hardware on receipt and provide secure lock-up for door hardware and sliding door materials delivered to Project site.
Keep all materials in their original, unopened containers/ packaging until installation.
B. Tag each item or package separately with identification coordinated with the final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item to package.
C. Manufacturer will be immediately notified of any damage caused during shipping.
D. Store and handle all materials according to manufacturer's instructions.
08 34 00 - 4
E. Store all materials indoors in dry, clean areas.
F. Protect all materials and finishes during the storage, handling, and installation to prevent damage.
1.9 COORDINATION
A. Coordinate layout and installation of floor-recessed door hardware with floor construction.
B. Verify if measurements for Sliding Door Systems are calculated from
Door Slab Width or Clear Opening in Door Schedule.
C. Installation Templates: Distribute doors, frames, and other work specified to be factory prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.
D. Security: Coordinate installation of door hardware, sliding door materials and access control with Owner’s security consultant.
E. Existing Openings: Where hardware components are scheduled for application to existing construction or where modifications to existing door hardware are required, field verify existing conditions and coordinate installation of hardware and sliding door materials to suit opening conditions to provide proper door operation.
PART 2 – PRODUCTS
2.1 BASIS OF DESIGN
A. Serenity Sliding Door Systems or equal product matching criteria.
2.2 INTERIOR ALUMINUM-FRAMED SLIDING DOORS
A. Provide clear aluminum top track, receiving channel, carriage assemblies, full gasketing, pulls and or locks, and related components.
B. Assembly:
1. Provide wall blocking within metal stud walls as required by manufacturer of sliding door assembly.
2. Joints and Connections: Flush, hairline width, and waterproof, accurately, and rigidly joined corners.
C. Wood Door Finish: Refer to Section 08 14 00 INTERIOR WOOD DOORS. Doors to be part of the manufacturer assembly.
D. Specified Wall Thickness:
1. 4-7/8” or as shown on plans. Verify in field all dimensions.
08 34 00 - 5
E. Frame Profiles: Extruded aluminum Cased Opening Frame with Snap on Trim with replaceable receiving channel.
F. Handles:
1. Long Back-to-Back Ladder Pull” 16” long x 1” diameter. Finish
612. Coordinate with
G. Finish:
1. Clear Anodized (Standard)
H. Track System Components:
1. Clear Anodized finish pre-installed rolling track system set to manufacturer specifications.
i. Preinstalled Track System Components
ii. Preinstalled Soft Close and Roller Assembly
2. Fascia: Extruded Aluminum with end caps
3. Quiet comfort roller system
4. Automatic Door Bottom
I. Optional Accessories:
1. Acoustic Door Bottom
2. Mechanical Spring Closer
J. Door thickness: 1 3/4 Inches. Reference Specification Section 08 14 00
INTERIOR WOOD DOORS.
K. Glazing: As indicated per door schedule.
L. STC Rating of Assembly:
1. Control room doors: STC 50.
2. Exam rooms doors: STC 40.
2.3 DOOR OPERATING HARDWARE
A. Manufacturers: Door hardware manufactures are as determined by the manufacture of the integrated Door Opening Assemblies in compliance with specified hardware requirements for applications as indicated.
B. Back-to-Back ladder pulls installed with concealed set screw under the pull.
C. Hardware Options: See Section 08 71 00 – Door Hardware.
1. Door Lock Functions: Back-to-Back Ladder Pulls w/ Deadlock:
i. SD5450: Office Keyed Lock with a Back-to-Back Ladder
Pull. ADA Compliant thumbturn.
2.4 DOOR LEAVES
08 34 00 - 6
A. Door Leaves must be factory machined and prepped for hardware, including function and pilot holes.
1. 1-3/4” Flush Wood Door. Reference Spec Section 08 14 00 INTERIOR
WOOD DOORS.
i. Stile widths are 6” with a 10” bottom rail.
2. Door Slab size 8” larger than clear opening width.
2.5 DOOR COMPONENTS
A. Extra Heavy Duty Clear Anodized Aluminum Track System (Made in the USA)
B. Receiving Channel
C. 3-sided Perimeter Seal System
D. Soft Close and Open System
E. Pre-installed Track
F. Aluminum Cased Open Frame
G. Snap-on Trim
H. Bottom Door Guide
2.6 FINISHES
A. Door Hardware: Provide door hardware of the same finish, unless otherwise indicated.
1. Finish: US32D Stain Stainless Steel – Pulls, Lockbodies, Thumbturns, Indicators
2. Finish: US10 (612) – Key Cylinders
BHMA A156.18 2. Exceptions:
i. Where base material metal is specified to be different, provide finish that is an equivalent appearance in accordance with BHMA A156.18
B. Track System:
1. Clear Anodized aluminum.
C. Wood Door Finish: Refer to Section 08 14 00 INTERIOR WOOD DOOR
PART 3 - EXECUTION
3.1 VERIFICATION
A. Verify that wall thickness is consistent and matches wall types called out on plans.
B. Verify wall openings are plumb, square, level, and true.
C. Verify that openings are ready to receive work and opening dimensions and clearances are as indicated on approved shop drawings.
D. Verify that floor is level.
08 34 00 - 7
E. Notify the owner and architect if any conditions are present that could affect door installation or performance.
F. Do not begin Installation if the above conditions are not remedied.
3.2 INSTALLATION
A. Verify that all installers have reviewed all training materials in installation of Sliding Door Systems.
1. Provide proper training for installation of Sliding Door
System.
B. Install doors in accordance with manufacturer’s requirements and instructions.
C. Coordinate frame anchor placement with wall construction.
D. Adjust sliding doors for correct orientation according to manufacturer’s instructions.
3.3 TOLERANCES
A. Maintain dimensional tolerances and alignment with adjacent work.
B. Maximum Variation from Plumb: 1/16 inch (1.6 mm).
C. Maximum Variation from Level: 1/16 inch (1.6 mm).
D. Longitudinal or Diagonal Warp: Plus, or minus 1/8 inch (3.2 mm) from 10 foot (3 m) straight edge.
3.4 MAINTENANCE
A. Damage to Sliding Door must be repaired in accordance with instructions of manufacturer and approval from architect and owner.
B. Protect sliding doors from damage during construction and installation.
C. Protect installed products from damage until Date of Substantial
Completion.
3.5 CLEANING
A. Remove protective material from factory finished surfaces.
B. Remove labels and visible markings.
C. Wash surfaces by method recommended and acceptable to sealant and sliding door manufacturer; rinse and wipe surfaces clean.
D. See Section 01 74 19 - Construction Waste Management, for additional requirements.
3.6 ASSURANCE PROGRAM
A. Manufacturer can offer an Assurance Program which will provide technical training and project support pre- and post-installation of
Integrated Sliding Doors Assemblies for projects larger than 100
08 34 00 - 8 openings for no additional cost to minimize facility issues through product life cycle.
B. Prior to product shipment, the manufacturer will offer on-site installation training to the subcontractor and distributor in proper installation techniques. Training will be documented in the
Installation Training Report.
C. During construction, before installation, the manufacturer will provide a random of audit of at least 20% of the rough openings to determine if the construction is meeting requirements.
D. Manufacturer will offer a Pre-Installation Report based on findings.
E. Manufacturer will provide a Post-Installation Registration Report checking each Integrated Sliding Doors Assemblies for installation and performance quality.
F. Manufacturer will provide on-hands parts inventory and training on how to replace or repair system components that can be damaged in the field.
G. Manufacturer will provide an audit and report of Integrated Sliding
Doors Assemblies one year after installation to ensure functionality.
The Manufacturer will notify and collaborate with Facility Manager to rectify any issues impeding complete functionality of Sliding Door
Systems.
- - - END - - -