This document is a detailed architectural drawing showing wall type specifications for a renovation project at the Battle Creek VA Medical Center. The drawing provides comprehensive technical details for three primary wall types: Type A (Typical Partition), Type B (One-Sided Partition), and Type R (Rated Partition), with precise engineering specifications for each wall configuration. The technical drawings include specific measurements for cold-formed steel framing, gypsum board layers, insulation types (such as batt insulation), sound attenuation requirements, track and stud configurations, and structural connection details. The document includes section views illustrating floor, ceiling, and structural connections, with annotations for stud sizes, gauge, material strengths, and Underwriters Laboratories (UL) ratings. The drawing is part of bid documents for the VA Medical Center's Audiology renovation project, dated January 17, 2025, with a bid addendum issued on May 9, 2025.

View the file

Other files

File Type Posted
Award email notice - 515-23-101.pdf PDF
07.5_10-AE101 - FIRST FLOOR PLAN.pdf PDF
083400 SLIDING DOOR OPENING ASSEMBLIES.pdf PDF
081113 HOLLOW METAL DOORS AND FRAMES.pdf PDF
07.7_10-AE112 - FIRST FLOOR ENLARGED PLANS AND ELEVATIONS.pdf PDF
07.6_10-AE111 - FIRST FLOOR ENLARGED PLANS AND ELEVATIONS.pdf PDF
Addendum 001 Summary.pdf PDF
107326 CANOPY COVERINGS V2.pdf PDF
13.12_M502 - MECHANICAL DETAILS.pdf PDF
07.13_10-AF701 - FINISH AND SIGNAGE PLAN AND SCHEDULES.pdf PDF
223500 DOMESTIC WATER HEAT EXCHANGERS.pdf PDF
07.15_10-AQ731 - EQUIPMENT PLANS.pdf PDF
36C25025B0019 0004.docx DOCX document
36C25025B0019 0003.docx DOCX document
Wage Determination - MI20240079 - 4-4-25 - Calhoun MI.pdf PDF
Bid RFI 03 Attachment Install ADA Compliant Access Building 10 Hand Rail System.pdf PDF
Bid RFI 08 Attachment B AE18665 Preliminary Design Package Rev C.pdf PDF
Bid RFI 08 Attachment A 13 12 M502 - MECHANICAL DETAILS.pdf PDF
36C25025B0019 0002.docx DOCX document
S04 - Pre Bid Site Visit Attendance Log - 515-23-101 Signed.pdf PDF
S04 - Pre-Bid Site Visit Agenda - 515-23-101.pdf PDF
36C25025B0019 0001.docx DOCX document
S02 J-A Hirsch - 515-23-101.pdf PDF
S02 ATTACHMENT VAAR 852.219-75 LIMITATIONS OF SUBCONTRACTING CERT - 515-23-101.docx DOCX document
S02 Drawings - 515-23-101 - BID DOCS 100.pdf PDF
S02 J-A ALC DDC - 515-23-101.pdf PDF
S02 Contractor EMR Certification Form - 515-23-101.docx DOCX document
S02 RFI Form - 515-23-101.doc DOC document
36C25025B0019_1.docx DOCX document
S02 J-A Pelco - 515-23-101.pdf PDF
S02 515-23-101 - BID DOCS 100 - Specifications - 3-27-25.pdf PDF
S02 J-A Simplex 515-23-101.pdf PDF
S02 J-A Kaba - 515-23-101.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTINUOUS SEALANT AT BOTH SIDES OF TRACK

SCHEDULED BASE

CONTINUOUS TRACK AND FASTENERS @ 16" O.C. MAX

FULL HEIGHT SOUND ATTENUATION BLANKET

(1) LAYER GYPSUM BOARD ON EACH SIDE

SCHEDULED CEILING

SECTION AT FLOOR

SECTION AT CEILING

TOP OF STRUCTURAL SLAB WITH SCHEDULED FLOOR FINISH

COLD FORMED STEEL FRAMING

SUBSTRATE [1] SUBSTRATE [2]MARK

3 1/2" BATTA1 COLD FORMED STEEL4 7/8"

TYPE A - TYPICAL PARTITION

(1) 5/8 GYPSUM BOARD

TYPE "X"

WALL THICKNESS CORE STRUCTURE

(1) 5/8 GYPSUM BOARD

TYPE "X"

INSULATION /

BATT

STUD SIZE RATING UL

3 5/8" -

6" BATTA2 COLD FORMED STEEL7 1/4" (1) 5/8 GYPSUM BOARD

TYPE "X"

(1) 5/8 GYPSUM BOARD

TYPE "X"

6" -

EXTEND WALL 6" PAST CEILING IF ONE OR

BOTH SIDES ARE ACT OTHERWISE

CONCLUDE AT CEILING HEIGHT

6"

EXTEND 3 1/2" BATT INSULATION 2'-0" MIN ON BOTH SIDES

ALTERNATE BRACING AT 48" O.C. MAX TO DECK ABOVE

A3

A4

> STC 50

> STC 55

UL4193 1/2" BATTCOLD FORMED STEEL5 1/2" (1) 5/8 GYPSUM BOARD

TYPE "X"

(2) 5/8 GYPSUM BOARD

TYPE "X"

3 5/8"

3 1/2" BATTCOLD FORMED STEEL6 3/4" (2) 5/8 GYPSUM BOARD

TYPE "X"

(3) 5/8 GYPSUM BOARD

TYPE "X"

3 5/8"

UL419

UL419

UL419

FIELD VERIFY DEPTH OF

STRUCTURE

APPROX LINE OF CEILING

SEE REFLECTED CEILING

PLAN FOR PROPOSED

CEILING HEIGHTS

UNDERSIDE OF

STRUCTURAL DECK

MECHANICAL

PENETRATION

ROUGH OPENING

DOOR

ROUGH

OPENING

WINDOW

ROUGH

OPENING

MECHANICAL

PENETRATION

ROUGH OPENING

TOP OF SLAB

H

H

H

H

H

H J J

JJ

S

S

S

S

S

S

J J

JJ

SPAN 4 TO 6 FT:

6" STUD, 20 GA

SPAN 6 TO 10 FT:

8" STUD, 16 GA

SPANS 10 TO 16 FT:

8" STUD, 14 GA

HEADER: SECTION H-H

TYPE A

JAMB: SECTION J-J SILL: SECTION S-S

TYPE B

C-STUD

CSJ, 50 KSI

TRACK STUD

CSJ, 50 KSI

TRACK STUD,

TSB, 33 KSI

SPANS: > 4 FEET

3 5/8" STUD

20 GA

JAMB STUD

(BEYOND)

#8 SCREWS @ 6"

O.C. MAX., TYP.

#8 SCREWS @ 6"

O.C. MAX., TYP.

TYPE A

TYPE B

TYPE A

TYPE B

CLIP ANGLE

ATTACHMENT TOP

AND BOTTOM

JAMB STUD

(BEYOND)

STUD PER PARTITION

SCHEDULE

SPAN 4 TO 6 FT:

6" STUD, 20 GA

SPAN 6 TO 10 FT:

8" STUD, 16 GA

SPANS 10 TO 16 FT:

8" STUD, 14 GA

SPANS: > 4 FEET

3 5/8" STUD

20 GA

DOUBLE C-STUDS

CSJ, 50 KSI

TRACK STUD CSJ, 50 KSI

TRACK STUD,

TSB, 33 KSI

#8 SCREWS @ 6"

O.C. MAX., TYP.

#8 SCREWS @ 6"

O.C. MAX., TYP.

CLIP ANGLE ATTACHMENT

TOP AND BOTTOM

STUD PER PARTITION

SCHEDULE

JAMB STUD

(BEYOND)

#12 - 14 FASTENERS

@ 24" O.C. MIN. EA. SIDE

TRACK STUD

TSB 33 KSI

(BELOW)

STUD PER PARTITION

SCHEDULE

STUD PER PARTITION

SCHEDULE

OPENING

OPENING

TRACK STUD TSB 33 KSI

(BELOW)

#12 - 14 FASTENERS

@ 24" O.C. MIN.

CLIP ANGLE

ATTACHMENT

(BEYOND)

CLIP ANGLE

ATTACHMENT

(BEYOND)

#12 - 14 FASTENERS

@ 24" O.C. MIN.

TRACK STUD TSB 33 KSI

(BELOW)

TRACK STUD TSB 33

KSI (BELOW)

C-STUD

CSJ, 50 KSI

C-STUD

CSJ, 50 KSI

TOP OF STRUCTURAL SLAB WITH SCHEDULED FLOOR FINISH

3 5/8" COLD FORMED STEEL FRAMING - CAN BE REDUCED

IF NOT IN PLUMBING WALLS

FULL HEIGHT SOUND ATTENUATION BLANKET

(1) LAYER GYPSUM BOARD

SECTION AT FLOOR

SUBSTRATE [1] SUBSTRATE [2]MARK

3 1/2" BATT B1 COLD FORMED STEEL4 1/4" -

WALL THICKNESS CORE STRUCTURE

(1) 5/8 GYPSUM BOARD

INSULATION /

BATT

STUD SIZE RATING UL

3 5/8" - -

TYPE B - ONE SIDED PARTITION

SCHEDULED CEILING SECTION AT CEILING

EXTEND 3 1/2" BATT INSULATION 2'-0" MIN

EXTEND WALL 6" PAST ACT CEILING

OTHERWISE CONCLUDE AT CEILING HEIGHT

6"

ALTERNATE BRACING AT 48" O.C. MAX TO DECK ABOVE

CONTINUOUS SEALANT AT BOTH SIDES OF TRACK

SCHEDULED BASE

CONTINUOUS TRACK AND FASTENERS @ 16" O.C. MAX

3 1/2" BATT B1 COLD FORMED STEEL4 1/4" - (1) VENEER PLASTER 3 5/8" - -

CONTINUOUS SEALANT AT BOTH SIDES OF RUNNER (TOP & BOTTOM)

SCHEDULED BASE

CONTINUOUS METAL "C" RUNNER AND FASTENERS @ 16" O.C. MIN.

FULL HEIGHT SOUND ATTENUATION BLANKET

(1) LAYER TYPE 'X' GYPSUM BOARD ON EACH SIDE

EXISTING STRUCTURE ABOVE

CONTINUOUS DEEP LEG DEFLECTION TRACK FOR 1/2" STRUCTURE

DEFLECTION.

SCHEDULED CEILING

SECTION AT FLOOR

SECTION AT CEILING

CONTINUOUS OR ACOUSTIC SEALANT IN ALL VOIDS ABOVE TRACK ON

BOTH SIDES OF PARTITION.

HOLD STUD 1/2" FROM TOP OF DEFLECTION TRACK, ATTACH GWB TO

STUDS ONLY AND ATTACH STUDS TO THE DEFLECTION TRACK.

TOP OF STRUCTURAL SLAB & SCHEDULED FLOOR FINISH

SECTION AT

STRUCTURE ABOVE

COLD FORMED STEEL FRAMING

FIRESTOP SEALANT AT EACH SIDE OF PARTITION

TYPE R - RATED PARTITION

SUBSTRATE [1] SUBSTRATE [2]MARK

3 1/2" MINERAL

FIBER.

R1 COLD FORMED STEEL4 7/8" (1) 5/8 GYPSUM BOARD

TYPE "X"

WALL THICKNESS CORE STRUCTURE

(1) 5/8 GYPSUM BOARD

TYPE "X"

INSULATION /

BATT

STUD SIZE RATING UL

3 5/8" SMOKE RESISTIVE UL U419

R2 COLD FORMED STEEL4 7/8" (1) 5/8 GYPSUM BOARD

TYPE "X"

(1) 5/8 GYPSUM BOARD

TYPE "X"

3 5/8" SMOKE BARRIER UL U419

R3 COLD FORMED STEEL4 7/8" (1) 5/8 GYPSUM BOARD

TYPE "X"

(1) 5/8 GYPSUM BOARD

TYPE "X"

3 5/8" 1-HOUR FIRE BARRIER UL U419

3 1/2" MINERAL

FIBER.

3 1/2" MINERAL

FIBER.

R4 COLD FORMED STEEL4 7/8" (1) 5/8 GYPSUM BOARD

TYPE "X"

(1) 5/8 GYPSUM BOARD

TYPE "X"

3 5/8" FULL HEIGHT - UNRATED -3 1/2" MINERAL

FIBER.

A. REFERENCE FLOOR PLANS AND PARTITION TYPES FOR ACTUAL FRAMING MEMBERS.

B. COORDINATE WITH MECHANICAL, ELECTRICAL, AND PLUMBING PLANS FOR OPENINGS THAT

ACCOMMODATE NEW MECHANICAL, ELECTRICAL, AND PLUMBING WORK.

C. ANCHOR GYPSUM BOARD WITH SCREWS AT 8" O.C. ON EDGES AT 12" O.C. IN FIELD PER UL DESIGN

NUMBERS LISTED.

D. LABEL ALL RATED PARTITIONS ABOVE CEILING WITH PLAQUE OR STENCILED SIGN READING: "(SMOKE BARRIER/ FIRE BARRIER/ SMOKE RESISTIVE) : SEAL AND PROTECT ALL OPENINGS". REFER TO PARTITION SCHEDULE ON THIS SHEET FOR RATING TYPE. SIGN SHALL BE PLACED ON BOTH SIDES OF PARTITIONS.

E. COORDINATE FRAMING WITH FIRE AND SMOKE DAMPERS AT PENETRATIONS IN RATED PARTITIONS.

F. PROVIDE CONTINUOUS FIRE RATED SEALANT AT THE PERIMETER OF ALL FIRE RATED WALLS AND

CHASES, INCLUDING THE TOP, BOTTOM, AND SIDE EDGES ON BOTH SIDES OF WALL.

G. ROUGH OPENING FRAMING CONFIGURATIONS DEPICTED ARE BASED ON COLD FORMED METAL STUD FRAMED WALL PARTITIONS AND ARE DIAGRAMMATIC IN NATURE, REFER TO ENLARGED DETAILS FOR

FURTHER CONTEXT

H. ALL COLD FORMED STEEL FRAMING IS 20 GAUGE OR HEAVIER.

I. PROVIDE A MINIMUM OF ONE STUD SEPARATION BETWEEN OUTLET BOXES AND OTHER PENETRATIONS

OCCURRING AT OPPOSITE FACE OF WALLS.

J. PROVIDE WALL REINFORCEMENT BETWEEN STUDS WHERE REQUIRED BY INSTALLATION OF MILLWORK

AND/OR WALL HUNG EQUIPMENT.

K. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL WALL STUD INSTALLATIONS EXCEEDING STUD

MANUFACTURER REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

L. REFER TO DIMENSION PLANS FOR AREAS THAT REQUIRE MOISTURE RESISTIVE GYPSUM.

M. PROVIDE CONTINUOUS NON-HARDENING ACOUSTICAL SEALANT AT TOP, SIDES AND EDGES OF BOTH SIDES OF WALL AT ALL NON-RATED GYPSUM BOARD PARTITIONS SCHEDULED TO RECEIVE SOUND

ATTENUATION BLANKETS.

N. ALL PENETRATIONS AT NON-RATED WALLS SHALL BE SLEEVED AND PACKED AIRTIGHT WITH SAFING INSULATION AND SEALANT. ALL JOINT OF GYPSUM BOARD PANELS SHALL BE STAGGERED, TAPED, AND

SEALED. FRAMING TO 1/2" +/- CLEARANCE AT PERIMETER OF MECHANICAL DUCTWORK.

O. SOUND ATTENUATION BATTS (SAB) ARE TO BE PLACED IN ALL PARTITIONS WHICH ENCLOSE A ROOM

UNLESS NOTED OTHERWISE.

G E N E R A L P A R T I T I O N N O T E S

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Date:Revisions:No.

A u to d e s k D o c s /B a tt le

C re e k V

A

R e n o v a te

A u d io lo g y B

/F

F E

B a tt le

C re e k

R e n o v a te A u d io lo g y

B rv t

/9

/2

:5

:0

P M

GI002

WALL TYPES

01/17/2025 SS CD

RENOVATE AUDIOLOGY 515-23-101

5500 Armstrong Rd, Battle Creek, MI

BID DOCUMENTS 100%

10 & 136

BATTLE CREEK

VA MEDICAL

CENTER Approved: Veteran's Affairs Medical Center

1/4" = 1'-0"

FRAME WALL ROUGH OPENING DIAGRAM

3" = 1'-0"

HEAD JAMB & SILL CONFIGURATIONS - TYPICAL

BID DOCUMENTS 01/17/2025

1 BID ADDENDUM #1 05/09/2025

Sheets
GI002 - WALL TYPES