610-16-104 Upgrade Emergency Power Addendum Drawings 2021 0402 sealed_Part2.pdf
PDF 5 MB Posted
- Attached to
- Z1DA--Upgrade Emergency Power 138 610-16-104
- Solicitation number
- 36C25020B0081
About this file
This notice announces an upcoming Invitation for Bid for upgrade emergency power services at the Northern Indiana HealthCare System VA Medical Center in Marion, Indiana. The project involves upgrading emergency power in Building 138 and has a project magnitude between $5-10 million. The solicitation will have a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses, who must be small under NAICS code 238210. Bids are due approximately 30 days after solicitation posting on August 14, 2020. The awarded contractor must perform a minimum of 15% self-performance and complete the project within 600 calendar days of the notice to proceed. The notice provides contact information and instructions on obtaining documents, attending site visits, and submitting questions.
View the file
Other files
Show 40 more
Latest 50 of 61 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BASE PLATE KIT
POST ADJUSTING
SCREWS
ADJUSTABLE INDICATOR
POST WITH REMOTE
ELECTRONIC/ALARM
POSITION INDICATOR
SWITCH & BUILDING LABEL
NOTE:
POST INDICATOR, BASE PLATE
KIT, AND VALVE SHALL BE FROM
SAME MANUFACTURER
2.
5' 3.
0'
GRADE
GATE VALVE
POST INDICATOR VALVE ASSEMBLY
NO SCALE
FINISHED GRADE
4' -0
" M
IN
C O
VE
R
12" 12"OD PIPE
MAX MAX
TRENCH WIDTH
PI
PE
NO SCALE
WATERLINE/SEWER TRENCHING,
PIPE BEDDING TO BE
6" LAYERS
COMPACTED IN
GRANULAR FILL CLASS I OR II
WATER OR SEWER PIPE
BEDDING & BACKFILLING
FO
R
W
AT
ER
L
IN
E
NOT TO SCALE
DETAIL-TAPPING TEE AND VALVE
TAPPING TEE FOR
CONNECTION TO
EXISTING WATER MAIN
RESILIENT SEATED GATE
VALVE - TAPPING TEE
JOINT x MECHANICAL JOINT
WATERLINE
POST INDICATOR BASE
AT POST INDICATOR
(SEE DETAIL)
NOTE: GATE VALVE SHALL BE NON-RISING STEM,
RESILIENT SEATED GATE WITH COUNTER CLOCKWISE
TO OPEN OPERATION PER AWWA C509 OR C515.A
A
90° BENDS
A
A
45° BENDSSECTION A-A
1. BLOCKING SIZE IS DESIGNED FOR 3000 POUNDS PER SQUARE
FOOT SOIL BEARING AND 150 POUNDS PER SQUARE INCH
INTERNAL PRESSURE.
2. CONCRETE SHALL BE 4000 PSI COMPRESSIVE STRENGTH.
3. THESE SAME DIMENSIONS SHALL BE USED FOR BOTH LONG &
SHORT BODY FITTINGS.
18"
D
4" M
AX
20"
CONCRETE BLOCKING FOR HORIZONTAL BENDS
NOT TO SCALE
D = 13" D = 12"
TRENCH BACKFILL SATISFACTORY
EXCAVATED OR BORROW
MATERIAL. WHEN IN PAVEMENT
AREAS USE COMPACTED GRANULAR
FILL.
CONCRETE
BLOCKING
CONCRETE
BLOCKING
CONCRETE
BLOCKING
NOTE: A COMBINATION OF RESTRAINED JOINTS AND THRUST BLOCKING MUST BE USED WHERE THE LENGTH FROM ONE BEND TO THE NEXT IS LESS THAN THE RESTRAINED LENGTH SHOWN ON THE FOLLOWING TABLE. (EXAMPLE: A COMBINATION OF RESTRAINED JOINTS AND CONCRETE THRUST BLOCKING IS REQUIRED ON AN 8" MAIN IF THE DISTANCE BETWEEN A 45° BEND AND A TEE IS LESS THAN 48'; 11' FOR AN
8"-45° BEND AND 37' FOR AN 8" TEE.)
RESTRAINED JOINT LENGTHS
RESTRAINING JOINT SYSTEMS ARE ACCEPTABLE WHEN DESIGNED IN ACCORDANCE WITH "THRUST RESTRAINT DESIGN FOR DUCTILE IRON PIPE", PUBLISHED BY THE DUCTILE IRON PIPE RESEARCH ASSOCIATION (DIPRA). RESTRAINING GLANDS, MANUFACTURED OF DUCTILE IRON CONFORMING TO ASTM A536-80 SPECIFICATIONS, OR LOCKING GASKETS SUCH AS FIELD
LOK, OR EQUAL, SHALL BE USED.
BEND
ANGLE
DIA OF WATERMAIN
11-1/4°
22-1/2°
45°
TEE, 90°
6" 8" 10" 12"
2 3 4 5
8 11 14 19
26 37 47 66
TABLE FOR REQUIRED RESTRAINT LENGTHS BASED ON:
100 PSF SOIL UNIT WEIGHT 0.25 SOIL FRICTION COEFFICIENT
150 PSI WATER PRESSURE 1.25 FACTOR OF SAFETY
L
L
NOT TO SCALE
MIN CLASS I OR II
BEDDING 12" OVER
PIPE INCLUDING
BELLS
UTILITY MARKING TAP
TOPSOIL (4" MINIMUM) IN LAWN AREAS.
IN PAVEMENT AREAS SEE PAVEMENT
REPLACEMENT OR CONCRETE DRIVE DETAILS.
L
12.75"
(MIN.)
TYPE A HYDRANT INSTALLATION WITH BLOCKING
NOT TO SCALE
1. COORDINATE NEW WATER MAIN CONNECTION TO EXISTING
MAIN WITH UTILITY OWNER.
2. WATER MAIN SHALL BE DUCTILE IRON PIPE (CLASS 53) WITH
PUSH-ON OR MECHANICAL JOINTS PER AWWA C151 OR PVC
AWWA C900 CLASS 200.
3. WATER MAIN FITTINGS SHALL BE DUCTILE IRON WITH
MECHANICAL JOINTS PER AWWA C110 OR C153 UNLESS
NOTED OTHERWISE.
4. ALL BURIED DUCTILE IRON PIPE AND FITTINGS SHALL BE
CEMENT MORTAR LINED PER AWWA C104 WITH ASPHALTIC
EXTERIOR COATING AND POLYEHELENE ENCASEMENT PER
AWWA C105.
5. ALL BENDS AND FITTINGS SHALL BE PROVIDED WITH
CONCRETE BLOCKING OR JOINT RESTRAINING GLANDS PER
DETAILS.
6. PROVIDE UTILITY MARKER TAPE ABOVE MAIN FOR ALL PIPE
AND LOCATION WIRE FOR ALL PVC PIPING.
WATER MAIN NOTES
ELEVATIO
N
EL
EV
AT
IO
N
STATION
PROFILE - FIRE MAIN
-0+25 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00
EX
. 4
" G
AS
(F
IE
LD
V
ER
IF
Y)
EX
. W
AT
ER
(F
IE
LD
V
ER
IF
Y)
EX
. 1
6" W
AT
ER
(F
IE
LD
V
ER
IF
Y)
EX
. 4
" W
AT
ER
(F
IE
LD
V
ER
IF
Y)
EX
. E
LE
C
. D U
C
TB
AN
K
(F
IE
LD
V
ER
IF
Y)
EX
. E
LE
C
(F
IE
LD
V
ER
IF
Y)
EX
.S
TE
AM
(F
IE
LD
V
ER
IF
Y)
EXISTING GRADE
EXISTING GRADE
(FIELD VERIFY)
4' MIN
COVER
NEW 8"x6" FIRE
HYDRANT
ANCHORING TEE
NEW 8"x6"
REDUCER
NEW 8" HORIZONTAL
11.25° ELBOW
NEW 8"
HORIZONTAL
45° ELBOW
NEW 8"x6" TEE
FOR FIRE
HYDRANT
NEW 8"
HORIZONTAL
45° ELBOW
NEW 8"x4" TEE & 4" GATE
VALVE FOR CONNECTION
TO EXISTING BUILDING
WATER SERVICE
NEW 6"
FIRE MAINNEW 8"
FIRE MAIN
NEW 8"
FIRE MAIN
N
EW
E M
C S.
D U
C
TB
AN
K
(S
EE
E M
C S
PL
AN
S)
N
EW
E M
C S.
D U
C
TB
AN
K
(S
EE
E M
C S
PL
AN
S) N
EW
E
LE
C
. D U
C
TB
AN
K
(S
EE
E
LE
C P
LA
N
S)
PROFILE - FIRE MAIN
1. NEW 6" GATE VALVE AND POST INDICATOR.
2. CONNECT TO EXISTING 16" FIRE MAIN WITH 16"x8" TAPPING TEE
AND VALVE.
3. NEW 6" FIRE MAIN BUILDING SERVICE ENTRY - INSTALL BELOW
FOOTER AND PENETRATE SLAB INSIDE BUILDING. TERMINATE END
OF PIPE WITH GROOVED JOINT END & CAP FOR PRESSURE
TESTING. COORDINATE LOCATION WITH BUILDING FIRE
PROTECTION PIPING WORK. (SEE PLAN ON SHEET CU102).
4. CONCRETE FILL BELOW FOOTER.
5. NEW 6" 90° ELBOW W/ MECHANICAL JOINT RESTRAINT GLAND
APPROVED BY OWNER W/ CONCRETE BLOCKING.
CODED NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DB PFRevisions: Date:
Marion VA Marion, IN
#610-16-104
CONSTRUCTION DOCUMENTS
10/28/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF
513.579.0042
ADDENDUM NO. 4 11/23/2020 CU103
WATER SERVICE
PROFILE & DETAILS
0 10' 20' 40'
HORIZONTAL SCALE
0 10' 20'
VERTICAL SCALE
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:5
:0
P
M
194SI-001
STRUCTURAL GENERAL NOTES
PM CL
GENERAL STRUCTURAL NOTES:
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS AND
CONDITIONS AT THE JOB SITE AND TO CROSS-CHECK DETAILS AND
DIMENSIONS ON THE STRUCTURAL DRAWINGS WITH THE RELATED
REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND
PLUMBING PLANS. FLOOR AND WALL OPENINGS, SLEEVES AND OTHER
ARCH., MECH., ELEC., REQUIREMENTS MUST BE COORDINATED BEFORE
THE CONTRACTOR PROCEEDS WITH CONSTRUCTION.
2. ALL ENGINEERING DESIGN, CONSTRUCTION, AND TESTING SHALL
CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING
CODE MOST RECENT EDITION (HEREIN REFERRED TO AS "THE CODE")
3. ALL STRUCTURAL WORK MUST BE TEMPORARILY BRACED AND
SUPPORTED UNTIL THE STRUCTURE IS SUFFICIENTLY COMPLETED AND
CAN SAFELY CARRY THE DESIGN & CONSTRUCTION LOADS.
4. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN
ON THE STRUCTURAL DRAWINGS.
5. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE
WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO
THE ATTENTION OF THE COR BEFORE PROCEEDING WITH ANY WORK
THAT IS INVOLVED IN THE CONFLICT.
6. THE MANUFACTURER PRODUCTS IDENTIFIED WITHIN MEET THE SALIENT
CHARACTERISTICS OF THIS SPECIFICATION. SUCH INFORMATION IS ONLY
PROVIDED TO SHOW AN EXAMPLE OF PRODUCTS WHICH MEET THE
SPECIFICATIONS AND DO NOT, IN ANY WAY, LIMIT THE OFFEROR FROM
PROVIDING PRODUCTS FROM OTHER MANUFACTURERS WHICH MEET THE
SALIENT CHARACTERISTICS AS IDENTIFIED IN THE SPECIFICATION.
STRUCTURAL STEEL:
1. MATERIAL STANDARDS:
WIDE FLANGE ASTM A992 Fy = 50,000 PSI ANGLE, CHANNELS, PLATES ASTM A36 Fy = 36,000 PSI SQUARE AND RECTANGLE HSS ASTM A500 Gr. B Fy = 46,000 PSI ROUND HSS ASTM A500 Gr. B Fy = 42,000 PSI PIPE ASTM A53 Gr. B Fy = 35,000 PSI
CONNECTION BOLTS ASTM A325N
ANCHOR RODS ASTM F1554 Gr. 36 Fy = 36,000 PSI
GROUT HIGH STRENGTH, NON-SHRINK, NON-METALLIC
ROOF DECK STEEL DECK INSTITUTE
2. STRUCTURAL AND MISC. STEEL SHALL BE DETAILED, FABRICATED AND
ERECTED IN ACCORDANCE WITH THE MOST RECENT EDITION OF AISC
STEEL CONSTRUCTION MANUAL AND CODE OF STANDARD PRACTICE.
STEEL JOISTS SHALL CONFORM TO THE LATEST EDITION OF STANDARD
SPECIFICATIONS OF THE STEEL JOIST INSTITUTE. METAL DECK SHALL
CONFORM TO THE STANDARD SPECIFICATION OF THE STEEL DECK
INSTITUTE.
3. USE BOLT CONNECTIONS AS SPECIFIED IN FRAMING DETAIL FOR SIZE AND
NUMBER OF BOLTS AND WELDS FOR ALL STRUCTURAL STEEL
CONNECTIONS. ALL BOLTED CONNECTIONS SHALL BE STANDARD ROUND
HOLES (UNLESS NOTED OTHERWISE). IF DETAIL IS NOT PROVIDED:
ALL BOLTED CONNECTIONS SHALL BE A325-N, 3/4" DIA. BOLTS (BRG. TYPE)
OR WELDED EQUIVALENT UNLESS OTHERWISE NOTED. SELECT
CONNECTIONS TO SUPPORT ONE HALF THE TOTAL LOAD CAPACITY FOR
EACH GIVEN BEAM AND SPAN. THE EFFECT OF CONCENTRATED LOADS
SHALL ALSO BE CONSIDERED.
4. FABRICATOR SHALL PROVIDE SAFETY CLIPS OR SEATS WHERE
APPLICABLE TO FACILITATE SAFE ERECTION.
5. CONNECTIONS UTILIZING STRUCTURAL BOLTS SHALL BE BEARING TYPE
AND TIGHTENED PER AISC TURN-OF NUT (FOR SLIP CRITICAL
APPLICATIONS IF SPECIFIED) OR SNUG-TIGHT SPECIFICATIONS.
6. CONNECTIONS MADE WITH HIGH STRENGTH STEEL BOLTS SHALL
CONFORM IN ALL RESPECTS TO THE CURRENT SPECIFICATIONS FOR
STRUCTURAL JOINTS USING 3/4" DIAMETER ASTM A325-N BOLTS (U.N.O.) AS
ENDORSED BY THE AISC. NO PAINT ON FAYING SURFACES.
7. WELDING SHALL BE DONE IN ACCORDANCE WITH "AMERICAN WELDING
SOCIETY" (AWS) D1.1, USING E70 ELECTRODES. WELDING SHALL BE
PERFORMED BY AN APPROVED CERTIFIED WELDER.
8. ALL EXPOSED WELDS SHALL BE FILLED AND GROUND SMOOTH WHERE
METAL MAY COME INTO CONTACT WITH THE PUBLIC.
9. NO CHANGES SHALL BE MADE IN THE STEEL STRUCTURE NOR ANY
MATERIAL CUT IN THE FIELD (UNLESS NOTED AS "FIELD CUT OR TRIM" ON
DRAWINGS), WITHOUT THE WRITTEN PERMISSION OF THE COR.
10. NO CUTTING, BURNING, OR HOLES OTHER THAN THOSE SPECIFICALLY
DETAILED SHALL BE ALLOWED THROUGH STRUCTURAL STEEL MEMBERS
WITHOUT THE PRIOR CONSENT OF THE COR. BOLT HOLES SHALL
CONFORM WITH THE GOVERNING AISC SPECIFICATION, AND SHALL BE
STANDARD HOLES UNLESS NOTED OTHERWISE.
11. THE COR SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES
BETWEEN THE DESIGN AND ACTUAL CONDITIONS NOTED IN THE FIELD.
12. CONTRACTOR SHALL PROVIDE NECESSARY LABOR, MATERIAL, AND
EQUIPMENT TO ERECT ALL MISCELLANEOUS IRON AND STEEL AS DETAILED
ON THESE DRAWINGS.
13. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO
FABRICATION.
14. ALL MATERIALS SHALL RECEIVE ONE SHOP COAT OF GRAY STANDARD
RUST INHIBITIVE STEEL PRIMER. ALL WELDS, ABRASIONS, AND OTHER
SURFACE DEFECTS IN THE SHOP PRIMER SHALL RECEIVE ONE FIELD
APPLIED COAT OF RUST INHIBITIVE PRIMER, PRIOR TO ENCLOSURE OR
FINAL ACCEPTANCE. PAINT SHALL NOT BE APPLIED TO THOSE MEMBERS
WHICH ARE TO BE FIREPROOFED.
15. PAINT ALL STEEL EXPOSED TO EARTH, OR IN CONTACT WITH CONCRETE
WITH ASPHALT PAINT (TNEMEC 46-465, OR EQUAL).
16. ALL STEEL ITEMS NOTED ON THE PLANS AS "HOT DIP GALVANIZED" SHALL
BE GALVANIZED AFTER FABRICATION, BY THE HOT DIP PROCESS IN
ACCORDANCE WITH ASTM A123 OR A386, AS APPLICABLE.
17. UNLESS OTHERWISE INDICATED, ROOF OPENINGS MADE IN EXISTING ROOF
STRUCTURE SHALL BE SUPPORTED ON ALL EDGES BY L4X4X1/4 FOR
SPANS OF 5’-0 OR LESS; AND BY C8X11.5 FOR SPANS BETWEEN 5’-0” AND
10’-0”. SPANS EXCEEDING 10’-0” SHALL REQUIRE SECTIONS APPROVED BY
THE COR. CONNECTIONS SHALL BE WELDED IN ACCORDANCE WITH AWS
D1.1 AND AISC, OR MINIMUM 2-BOLT CONNECTIONS ACCORDING TO AISC.
CONCRETE:
1. ALL CONCRETE WORK TO BE PERFORMED IN CONFORMANCE WITH THE
MOST RECENT EDITION OF ACI301 & ACI318-05 CODE REQUIREMENTS AND
DETAILING STANDARDS.
2. ALL READY MIXED CONCRETE SHALL CONFORM TO ASTM C94.
3. USE AIR ENTRAINED CONCRETE (6% + OR - 1.5%) FOR ALL AREAS EXPOSED
TO WEATHER, FROST IN SOIL, OR FREEZE THAW CYCLES.
4. ALL CONCRETE SHALL DEVELOP THE FOLLOWING COMPRESSIVE
STRENGTHS AT 28 DAYS (F`c) UNLESS NOTED OTHERWISE:
A. FOUNDATION CONCRETE F'c = 4000 PSI B. FLOOR SLAB CONCRETE F'c = 4000 PSI
5. ALL REINFORCING BARS, DOWELS, ANCHOR BOLTS AND OTHER INSERTS
SHALL BE SECURED IN POSITION PRIOR TO PLACING OF THE CONCRETE.
6. ALL HORIZONTAL BARS IN CONCRETE WALLS AND GRADE BEAMS SHALL BE
CONTINUOUS AND BENT AT ALL CORNERS AND INTERSECTIONS. PRE-BENT
"CORNER" BARS SUBSTITUTED FOR CONTINUOUS BENT BARS SHALL BE OF
SAME SPACING AS HORIZONTAL BARS AND SHALL BE OF SUFFICIENT
LENGTH TO PROVIDE REQUIRED LAP SPLICE LENGTHS.
7. DETAILING BENDING AND PLACING OF REINFORCING STEEL SHALL BE IN
ACCORDANCE WITH THE LATEST EDITION OF THE ACI CODE.
8. ALL CONCRETE FORMWORK SHALL BE ADEQUATELY TIED TOGETHER AND
BRACED TO FORM TRUE LINES, SQUARE CORNERS, AND PLUMB WALLS.
9. ALL CONCRETE MATERIALS AND WORKMANSHIP SHALL CONFORM TO
CHAPTER 19 OF THE INTERNATIONAL BUILDING CODE 2009 EDITION.
10. NO CONCRETE SHALL BE POURED SUBJECT TO FREEZING CONDITIONS, OR
ON FROZEN GROUND.
11. REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES,
ORNAMENTS, OR ACCESSORIES REQUIRED TO BE CAST INTO CONCRETE,
AND FOR LOCATIONS OF FLOOR FINISHES AND SLAB DEPRESSIONS.
12. FOOTINGS SHALL BE LOCATED ON THE CENTERLINE OF WALLS, PIERS, OR
COLUMNS, UNLESS NOTED OTHERWISE.
13. PROCEDURES FOR PLACEMENT OF CONCRETE SHALL BE IN STRICT
CONFORMANCE WITH ACI 304 "RECOMMENDED PRACTICE FOR
MEASURING, MIXING, TRANSPORTING, AND PLACING CONCRETE."
14. CONCRETE SLABS ON GRADE SHALL BE POURED ON COMPACTED SUB
GRADE OR UNDISTURBED SOIL. SLAB SURFACES SHALL BE SMOOTH AND
LEVEL, OR SHALL HAVE A SMOOTH EVEN SLOPE. CONCRETE FINISH SHALL
BE SMOOTH FOR INTERIOR FLOOR SLABS, AND BROOMED FOR EXTERIOR
WALKS. SEE PLANS FOR LOCATIONS AND FINISH.
15. BEAMS AND SLABS SHALL BE POURED MONOLITHICALLY, SO THAT NO
HORIZONTAL CONSTRUCTION JOINTS ARE PROVIDED. ANY CONSTRUCTION
JOINTS THAT ARE PLANNED BY THE CONTRACTOR SHALL BE SUBMITTED IN
WRITING TO THE ENGINEER FOR APPROVAL.
16. LOCATE ALL SLEEVES, OPENINGS AND EMBEDDED ITEMS, WHICH ARE
INDICATED ON DESIGN DRAWINGS. CHECK WITH OTHER TRADES TO
VERIFY THAT ALL SLEEVES, OPENINGS, AND EMBEDDED ITEMS ARE IN
PLACE AND LOCATED CORRECTLY PRIOR TO PLACEMENT OF CONCRETE.
17. PIPE MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES, BUT
SHALL NOT BE EMBEDDED THEREIN. SLEEVES SHALL BE WRAPPED WITH
EXPANSION JOINT FILLER MATERIAL TO ALLOW CONCRETE TO CURE
WITHOUT RESTRAINT. PIPES OR CONDUITS WITH DIAMETER EXCEEDING
ONE THIRD THE SLAB OR WALL THICKNESS SHALL NOT BE IN STRUCTURAL
CONCRETE UNLESS SPECIFICALLY DETAILED AS SUCH. SEE MECHANICAL
AND/OR ELECTRICAL DRAWINGS FOR LOCATIONS OF SLEEVES,
ACCESSORIES OR OTHER PENETRATIONS.
18. THE SURFACE OF ALL CONSTRUCTION JOINTS SHALL BE CLEANED TO
REMOVE ALL DUST, CHIPS, OR OTHER FOREIGN MATTER PRIOR TO THE
PLACEMENT OF ADJACENT CONCRETE.
19. SLAB CONTROL JOINTS SHALL BE INSTALLED WITH JOINT FORMERS WHEN
THE SLAB IS POURED , OR SAWCUT AS SOON AS THE CONCRETE WILL
ALLOW WITHOUT DAMAGE.
20. ALL EMBEDDED ITEMS SHALL BE PLACED IN THE FORMWORK PRIOR TO
PLACING CONCRETE. DRILLING AND GROUTING IS ACCEPTABLE SUBJECT
TO ENGINEER APPROVAL.
21. CONCRETE WALLS MAY BE BACKFILLED TO TWO-THIRDS THE WALL HEIGHT
ONCE 75% OF THE 28 DAY COMPRESSIVE DESIGN STRENGTH HAS BEEN
ACHIEVED. WALLS WITH TOP SLABS MAY BE BACKFILLED TO ONE-HALF OF
THE WALL HEIGHT PRIOR TO CASTING THE TOP SLAB.
REINFORCING STEEL:
1. ALL REINFORCING SHALL BE HIGH STRENGTH DEFORMED BARS, GRADE 60,
ASTM A615, WITH 60,000 PSI MINIMUM YIELD STRENGTH, UNLESS NOTED
OTHERWISE.
2. REINFORCEMENT PROTECTION: (U.N.O.)
A. CONCRETE POURED AGAINST EARTH = 3"
B. CONCRETE POURED IN FORMS BUT EXPOSED = 2"
TO WEATHER, EARTH OR LIQUID
C. SLABS AND WALLS NOT EXPOSED TO WEATHER OR EARTH = 1 1/2"
D. BEAMS, GIRDERS, AND COLUMNS NOT EXPOSED TO
WEATHER, OR IN CONTACT WITH EARTH = 1 1/2"
3. ALL REINFORCING BARS MARKED "CONTINUOUS" SHALL BE SPLICED AS
FOLLOWS:
A. SPLICES IN CONCRETE SHALL CONFORM TO THE LAP CHART
SHOWN ON THIS SHEET.
B. SPLICES IN MASONRY SHALL BE A MINIMUM OF 50 BAR
DIAMETERS, BUT NOT LESS THAN 24 INCHES.
4. DETAIL BARS IN ACCORDANCE WITH ACI DETAILING MANUAL AND ACI
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. PROVIDE
CORNER BARS.
5. ALL MASONRY REINFORCING SHALL BE PLACED AND SUPPORTED IN
CONFORMANCE WITH THE PROVISIONS OF THE LATEST EDITION OF ACI
530.1/ASCE-6/TMS 602.
6. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING AT
POSITIONS SHOWN ON THE PLANS.
7. TIE WIRE SHALL CONFORM TO ASTM A-82.
8. WELDED WIRE FABRIC SHALL CONFORM WITH ASTM A-185.
9. WELDED WIRE FABRIC SHALL BE SPLICED WITH A MINIMUM LAP OF TWO
MODULES.
10. DETAILING OF ALL BENT BARS SHALL COMPLY WITH THE LATEST EDITION
OF THE ACI CODE.
11. WELDING OF REINFORCING BARS IS NOT PERMITTED, UNLESS NOTED
OTHERWISE.
FOUNDATION:
1. ALL FOOTINGS SHALL BE ESTABLISHED ON PROPERLY UNDISTURBED SOIL
OR PROPERLY COMPACTED ENGINEERED FILL. SEE SPECIFICATION
SECTION 31 20 11.
2. ALL FOUNDATION BEARING AND FILL MATERIALS SHALL BE TESTED PRIOR
TO PLACING CONCRETE. SOIL FILL, AND SOIL BEARING MATERIAL PER
REQUIREMENTS BELOW.
3. ALL FILL AND BACKFILL MATERIAL SHALL BE NON-COHESIVE SOILS,
COMPACTED TO 95% MAXIMUM DENSITY PER ASTM D1557-70 MODIFIED
PROCTOR METHOD. THE UPPER 6" OF SUB GRADE SHALL BE SCARIFIED,
MOISTURE CONDITIONED, AND COMPACTED PER TESTS ABOVE.
4. SHOULD ANY CONDITIONS BE ENCOUNTERED THAT ARE UNUSUAL OR DO
NOT GIVE THE MINIMUM ALLOWABLE BEARING CAPACITIES (INDICATED
BELOW), OR COMPACTION LEVELS, THE COR SHALL BE NOTIFIED, AND
WORK SHALL CEASE. WORK SHALL NOT RESUME UNTIL THE
COR EVALUATES THE EXCAVATION, AND GIVES WRITTEN INSTRUCTIONS
TO RESUME FOUNDATION WORK.
5. MINIMUM ALLOWABLE SOIL BEARING PRESSURE: WALL FOOTINGS, Qal =
2000 PSF.
6. ALL EXCAVATION FOR STRUCTURES SHALL BE KEPT DEWATERED UNTIL
BACKFILL IS IN PLACE. EXCAVATION FOR STRUCTURES SHALL INCLUDE ALL
NECESSARY SHEETING AND SHORING.
7. WHERE THE FOUNDATION IS OVER EXCAVATED, REMOVE ALL DISTURBED
FOUNDATION SOIL AND REPLACE WITH GRANULAR MATERIAL PROPERLY
COMPACTED AS DIRECTED ABOVE.
8. ALL SLABS ON GRADE SHALL BEAR ON A MINIMUM 6" OF CLEAN GRANULAR
FILL CONSISTING OF SAND AND GRAVEL OR CRUSHED STONE. BASE
COURSE TO BE COMPACTED TO A MINIMUM 95% OF MODIFIED STANDARD
PROCTOR.
MASONRY:
1. CONCRETE MASONRY UNITS (CMU) ARE TO CONFORM TO ASTM C-90.
2. SEE SPECIFICATIONS FOR UNIT WEIGHT AND STRENGTH. IF NO
SPECIFICATIONS ARE PRESENT, USE STANDARD WEIGHT UNITS, GRADE N,
TYPE 1, (F'm = 1900 PSI)
3. GROUT SHALL CONFORM TO THE PROPORTION REQUIREMENTS OF ASTM
C-476, AND HAVE A MINIMUM COMPRESSIVE STRENGTH (F'c) OF 2000 PSI, WHEN MEASURED AT 28 DAYS.
4. SAND SHALL CONFORM TO ASTM C-144.
5. ALL HORIZONTAL REINFORCING STEEL IN CONCRETE BLOCK WALLS SHALL
BE CONTINUOUS AROUND CORNERS FOR 24" FROM CORNER IN EACH
DIRECTION.
6. HORIZONTAL JOINT REINFORCING SHALL BE "DUR-O-WAL LADUR" TYPE,
WITH No. 9 SIDE AND CROSS RODS IN EVERY OTHER COURSE, UNLESS
NOTED OTHERWISE.
7. ALL HORIZONTAL REINFORCEMENT SHALL BE DISCONTINUED AT VERTICAL
CONTROL JOINTS, UNLESS NOTED OTHERWISE.
8. ALL VERTICAL REINFORCING STEEL IN CMU WALLS SHALL BE CONTINUOUS
FROM THE FOOTING TO THE BOND BEAM, AND TERMINATED IN END
HOOKS. WHERE BOND BEAMS ARE NOT AT THE TOP OF A WALL,
REINFORCING SHALL BE CONTINUOUS THROUGH THE BOND BEAM TO TOP
WALL.
9. CONTRACTOR SHALL PROVIDE NECESSARY LABOR, MATERIALS, AND
EQUIPMENT TO LAY UP MASONRY AS SHOWN ON THE DRAWINGS, AND
SPECIFIED IN THE SPECIFICATION DOCUMENTS. ALL WORK SHALL BE LAID
PLUMB, TRUE, AND SQUARE WITH FILLED AND RAKED JOINTS.
10. ALL WALLS SHALL BE ADEQUATELY BRACED UNTIL SECURELY TIED TO THE
STRUCTURE FRAMES AND DIAPHRAGMS.
11. ALL MASONRY WORK SHALL BE LAID RUNNING BOND, UNLESS NOTED
DIFFERENTLY IN ARCHITECTURAL DOCUMENTS.
12. ALL MASONRY WORK BELOW GRADE SHALL HAVE CORES GROUTED SOLID
WITH GROUT CONFORMING TO ASTM C176. BELOW GRADE MASONRY
SHALL USE TYPE M OR S MORTAR.
13. SEE LINTEL SCHEDULE FOR LINTEL SIZES. ALL STEEL LINTELS IN EXTERIOR
WALLS SHALL BE HOT DIP GALVANIZED, UNLESS NOTED OTHERWISE.
14. MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM TO ALL
REQUIREMENTS OF "SPECIFICATIONS FOR MASONRY STRUCTURES (ACI
510.3/ASCE-6/TMS-602)," EXCEPT AS MODIFIED BY THE REQUIREMENTS OF
THESE CONTRACT DRAWINGS.
15. CONTROL JOINTS SHALL BE INSTALLED AT LOCATIONS SHOWN ON THESE
DRAWINGS. IN AREAS NOT NOTED ON DRAWINGS, A MINIMUM PLACEMENT
OF ONE SIDE ABOVE ALL OPENINGS 6'-0" WIDE OR LESS, AND AT BOTH
SIDES OF ALL OTHER OPENINGS, OR AT 20'-0" O.C. MAX.
16. NO WORK SHALL BE DONE SUBJECT TO FREEZING CONDITIONS.
STRUCTURAL DESIGN INFORMATION:
1. SNOW LOAD:
SNOW EXPOSURE FACTOR (Ce) 1.0 THERMAL FACTOR (Ct) 1.1
SNOW IMPORTANCE FACTOR (I) 1.2
GROUND SNOW LOAD (Pg) 30 PSF FLAT ROOF SNOW LOAD (Pf) 28 PSF SLOPED ROOF FACTOR (Cs) 0.8 BALANCED SNOW LOAD (Ps) 22 PSF
UNBALANCED SNOW LOAD 36 PSF
2. LIVE LOAD:
CONSTRUCTION 20 PSF
3. ROOF DEAD LOADS:
LIGHT GAUGE METAL TRUSSES 5 PSF
ROOF SHEATHING 2 PSF
STANDING SEAM ROOFING 3 PSF
MISCELLANEOUS 10 PSF
4. WIND LOADS:
BASIC WIND SPEED 90 MPH
WIND IMPORTANCE FACTOR (I) 1.15
WIND EXPOSURE CATEGORY 'B'
MAIN WIND FORCE RESISTING SYSTEM WIND PRESSURE:
MAIN WALL = 15.4 PSF
END WALL = 18.1 PSF
MAIN ROOF = -15.4 PSF
END ROOF = -16.1 PSF
COMPONENTS & CLADDING WIND PRESSURE:
MAIN WALL = +20.2 PSF, -24.1 PSF
END WALL = +20.2 PSF, -24.1 PSF
MAIN ROOF = +12.1 PSF, -19.2 PSF
END ROOF = +12.1 PSF, -24.8 PSF
CORNER ROOF = +14.9 PSF, -44.7 PSF
5. SEISMIC LOAD DATA BASED ON ASCE 7-16:
SEISMIC IMPORTANCE FACTOR (Ie) 1.5
SITE CLASS 'D'
SPECTRAL RESPONSE COEFFICIENTS:
Ss = 0.13 Sds = 0.138 S1 = 0.071 Sd1 = 0.114
SEISMIC DESIGN CATEGORY 'C'
BASIC SEISMIC FORCE RESISTING SYSTEM:
ORDINARY REINFORCED MASONRY SHEAR WALLS
RESPONSE MODIFICATION COEFFICIENT: R = 3
SEISMIC RESPONSE COEFFICIENT: Cs = 0.069
ABBREVIATIONS
ARCH ARCHITECTURE/ARCHITECTURAL
CJ CONSTRUCTION JOINT
CONC CONCRETE
DWGS DRAWINGS
EQ EQUAL
FFE FINISHED FLOOR ELEVATION
FND FOUNDATION
GALV GALVANIZED
MECH MECHANICAL
PL PLATE
STL STEEL
04/29/2020 Revisions: Date:
ADDENDUM 10 3/24/2020
D1
194SB-601
B4
194SB-601
B2
194SB-601
B4
194SB-601
B2
194SB-601
6" PAD FOR RTU-1
A
DCB
D3
194SB-601
D1
194SB-601
D1
194SB-601
D1
194SB-601
ENTRANCE
SLAB
FOUNDATION
ENTRANCE SLAB
FOUNDATION
4' - 4"
0' - 8"
0' - 8" 4' - 4"
MATCHLINE - SEE ABOVE
F1 F2 F2 F1
F2F3 F1F1
P1 P2 P2 P1
P2P2P1
/4
/8
/8
/4
1' - 0"
0' - 9 3/4"
8' - 2 1/4" 1' - 0" 0' - 9 3/4"
21' - 10 5/8" 21' - 10 5/8"
0' - 9 3/4"
1' - 0"
/4
F5
194SB-601
13' - 3 1/2"
/2
/4
/2
/2
/4
27' - 3 1/2" 17' - 3 5/8"
/8
A DCB
D1
194SB-601
D1
194SB-601
D1
194SB-601
SEE DETAIL A7/194SB-602
FOR TANK FOUNDATION
DETAIL
B9
194SB-601
B9
194SB-601
D3
194SB-601
B2
194SB-601
B4
194SB-601
ENTRANCE SLAB
FOUNDATION
D6
194SB-601
D6
194SB-601
SIM
ENTRANCE SLAB
FOUNDATION
B4
194SB-601
B2
194SB-601
0' - 8"
0' - 8" 4' - 4"
MATCHLINE - SEE BELOW
F2
P2
F3
P2
F2
F1
P1
F2
P2
F1
P1
D6
194SB-601
/4
/8
/8
/4
21' - 10 5/8" 21' - 10 5/8" 0' - 5 3/4" 1' - 4"
1' - 2" COORDINATE WITH TANK MANUFACTURER 1' - 2"
9' - 0 1/4"
FILL STATION
FOUNDATION
F5
194SB-601
F3
194SB-601
/2
1' - 4" 0' - 5 3/4"
4' - 4"
1' - 0"
0' - 9 3/4"
8' - 2 1/4"
1' - 0"
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:5
:4
P
M
194SB-101
FOUNDATION PLAN
PM CL
1/4" = 1'-0" F1
SGB FOUNDATION PLAN
1/4" = 1'-0"
F6
GENERATOR BUILDING AND STORAGE TANK FOUNDATION PLAN
04/29/2020 Revisions: Date:
D1
194SB-601
B4
194SB-601
B2
194SB-601
A
DCB
6" CONCRETE PAD
FOR SWTCHGEAR
B4
194SB-601
B2
194SB-601
CJ
SEE DETAIL A4
C J
S E
E D
E T
A
IL
A
C J
6" PAD FOR RTU-1
B7
194SB-601
D3
194SB-601
COORDINATE WITH SWITCHGEAR MANUFACTURER
35' - 0"
ENTRANCE
SLAB
ENTRANCE SLAB
D1
194SB-601
D1
194SB-601
5' - 0"
5' - 0"
MATCHLINE - SEE ABOVE
D1
194SB-601
P1 P2 P2 P1
P1 P2 P2
13' - 3 1/2"
/2
"F5
194SB-601
/4
/8
/8
/4
1' - 0"
0' - 9 3/4"
8' - 2 1/4" 1' - 0" 0' - 9 3/4"
21' - 10 5/8" 21' - 10 5/8"
0' - 9 3/4"
1' - 0"
/4
/2
/4
26' - 9 1/2" 17' - 3 5/8"
/8
C J
C J
11' - 8 1/2" 8' - 8 1/4"
/2
A DCB
B9
194SB-601
D3
194SB-601
OUTLINE OF
FUTURE
GENERATOR AND
SILENCER PAD
B9
194SB-601GRANULAR FILL
D5
194SB-601
STAIR
LANDING
B2
194SB-601
B4
194SB-601
ENTRANCE SLAB
ENTRANCE
SLAB
/2
D1
194SB-601
D1
194SB-601
A7
194SB-601
D6
194SB-601
D6
194SB-601
D6
194SB-601
D1
194SB-601
B2
194SB-601
B4
194SB-601
PIPE TRENCH
D9
194SB-601
/8
/8
5' - 0"
5' - 0"
MATCHLINE - SEE BELOW
C O
O R
D
IN
A T
E W
IT
H
G E
N E
R A
T O
R M
A N
U F
A C
T
6" CONCRETE PAD
FOR GENERATOR
AND SILENCER
COORDINATE WITH GENERATOR MANUFACTURER
34' - 0" P2
P1 P2 P1
P2
FILL STATION
SLAB
F5
194SB-601
F3
194SB-601
COORDINATE WITH TANK MANUFACTURER
C J
CJ - SEE DETAIL A4
S E
E D
E T
A
IL
A
2' - 2 1/4"
SIM
C J
C J
CJ
CJ
/8
13' - 1 1/4"
CMU WALL
- SEE ARCH
1' - 3 1/4" 1' - 0" F9
194SB-601
E9
194SB-601
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:5
:4
P
M
194SB-102
SLAB PLAN
PM CL
1/4" = 1'-0" F1
SGB SLAB PLAN
1/4" = 1'-0"
F6
GENERATOR BUILDING AND STORAGE TANK SLAB PLAN
(2) #5 BARS CONT.
(TYP. 3 SIDES)
#4 BARS CONT., TOP
& BOTTOM,
PROVIDE CORNER
BARS
8" FOUNDATION
WALL (TYP. 3 SIDES)
6" VOID
12" GRANULAR
FILL
#4 DWLS W/ STANDARD
HOOK @ 12" O.C.
ALTERNATE (TYP.)
6" CONC. APRON W/ 2", 20 GA
NON-COMP. FORM DECK (GALV.)
& 6X6 - W2. 9XW2. 9 WWF
2" BEARING
0' - 5" 0' - 8" 0' - 5"
C L
B E
L O
W G
R A
D E
3/4" CHAMFER
#5 @ 12" O.C.
6" VOID
12" GRANULAR
FILL
SLOPE 1/4"/FT
6" CONC. APRON W/ 2", 20 GA
NON-COMP. FORM DECK (GALV.)
& 6X6 - W2. 9XW2. 9 WWF
8" FOUNDATION
WALL (TYP. 3 SIDES)
#4 DWLS W/ STANDARD
HOOK @ 12" O.C.
ALTERNATE (TYP.)
#4 DOWELS
@ 12" O.C.
(2) #5 BARS CONT.
(TYP. 3 SIDES)
#4 BARS CONT., TOP
& BOTT. PROVIDE
CORNER BARS
#4 DWLS @ 12" O.C.
ACROSS OPNG., TYP.
DOOR FRAMING
AND THRESHOLD.
SEE ARCH. DWGS.
TREATED 2X6
WOOD BLOCKING
@ THRESHOLD
6" SLAB ON GRADE W/
6X6 - W2. 9XW2. 9 WWF
SEE FOUNDATION DETAIL
ON THIS SHEET FOR
REINFORCING
PREPARED SUBGRADE,
SEE FOUNDATION NOTE 8
2" BEARING
3"
2" BEARING
0' - 6" 1' - 0" 0' - 6"
B E
L O
W G
R A
D E
0' - 5" 0' - 8" 0' - 5"
VAPOR BARRIER
C L
3/4" CHAMFER
FFE= 0'-0"
1' - 0"
SEE ARCH FOR
REINFORCEMENT
90° HOOK
#4 @ 12" O.C.
#5 @ 12" O.C.
PREPARED SUBGRADE,
SEE FOUNDATION NOTE 8
#5 DOWELS @ 12" O.C.,
CMU & PANELS,
SEE ARCH DWGS
(3) #4 BARS CONT.
#5 BARS @ 12" O.C.
FOR REINFORCEMNT
SEE ARCH
C L
1' - 0" 0' - 6"0' - 6"
B E
L O
W G
R A
D E
VAPOR BARRIER
0' - 4 3/8"
0' - 7 5/8"
0' - 9 3/4"
6" SLAB ON GRADE W/
6X6 - W2.9XW2.9 WWF
FFE= 0'-0"
1' - 0"
90° HOOK
#4 @ 12" O.C.
#4 @ 12" O.C.
COORDINATE DIMENSIONS W/ EQUIPMENT SUPPLIER
EQUIPMENT
3/4" CHAMFER
CONC. FLOOR
/2
C L R
#4 BENT DOWELS W/ 3"
EMBED INTO FLOOR SLAB
AND 12" O.C. MAX. AROUND
PERIMETER
#4 BARS @
12" O.C., E.W.
TYP.
6"
6" SLAB ON
GRADE W/ 6X6 -
W2. 9XW2. 9 WWF
C L
SEE BOLT DETAIL ON 194SF-601
COMPACTED
BACKFILL
#4 @ 12" O.C.
#4 @ 12" O.C.
#4 CONT. @ 12" O.C.
B E
L O
W G
R A
D E
3/4" CHAMFER
2' - 5" 1' - 2" 2' - 5"
8" CMU WALL
(SEE ARCH.)
0' - 9 3/4"
#4 @ 12" O.C.
(3) #4 CONT.
0' - 3 3/4"
1' - 7 5/8"
0' - 6" 0' - 6"
FFE= 0'-0"
C L
TOP OF SLAB
0' - 0"
CMU & PANELS,
SEE ARCH DWGS
(4) #4 BARS CONT.
GRAVEL FILL
SEE ARCH
#4 BARS @ 12" O.C.
#4 DOWELS @ 12" O.C.
5 3/4"
1' - 4" 1' - 4" 1' - 4"
B E
L O
W G
R A
D E
#4 @ 12" O.C.
COMPACTED
GRANULAR
FILL
3/4" Ø EXP.
ANCHOR
W/ 4" EMBEDMENT
6" CONCRETE SLAB
ON GRADE, W/ 6x6 W2.9xW2.9 WWF (4'-0"x4'-0")
CROSS OVER STAIRS
3' - 0" 1' - 0"
1-1/4x3/16"
GRATING (GALV.)
L1-1/2 x1-1/2x1/4
W/ 1/4" STRAP
ANCHOR @ 12" O.C.
DAY TANK
(TYP.)
0' - 6" 1' - 0" #4 @ 12" O.C.
BY MANUFACTURER
0' - 6" 0' - 6"
PREPARED SUBGRADE,
SEE FOUNDATION NOTE 8
FFE= 0'-0"
4" GRANULAR
FILL
COMPACTED
BACKFILL
"2
G R
O U
T
FFE = 0'-0"
C L
1' - 5" 0' - 7" 0' - 9 3/4" 1' - 0" 0' - 6"
#4 BARS CONT.
#5 DWLS (TYP.)
1' - 0"
B E
L O
W G
R A
D E
0' - 7 5/8" 0' - 4 3/8"0' - 9 3/4"
6" SLAB ON GRADE W/
6X6 - W2.9XW2.9 WWF
90° HOOK
#4 @ 12"O.C.
#4 @ 12" O.C.
COMPACTED GRANULAR
BACKFILL
0' - 6" 0' - 6"
(1) #4 BAR CONT. (TYP.)
/8
C L
6" REINF. CONC. SLAB
ON GRADE, W/ 6x6 W2.9xW2.9 WWF
3/4" CHAMFER
SLOPE
COMPACTED
GRANULAR FILL
BLDG. CONC. SLAB
AND FND. WALL,
SEE FND. PLAN
3/4" CHAMFER
6" REINF. CONC. SLAB
ON GRADE, W/ 6x6 W2.9xW2.9 WWF
(1) #4 BAR
CONT. 0' - 6" 0' - 6"
COMPACTED
GRANULAR
FILL
6" CONCRETE SLAB
ON GRADE, W/ 6x6 W2.9xW2.9 WWF
(TYP.)
0' - 6"
ACCU-1 ACCU-1
NOTE:
1. SEE SHEET 175MH-101 FOR LOCATION OF ACCU-1 AND ACCU-2
DAY TANK
#4 @ 12" O.C.
BY MANUFACTURER
0' - 6"
8" CMU WALL
0' - 3 3/4"
0' - 9 3/4"
0' - 6"0' - 6"
#4 @ 12" O.C.
8" CMU WALL
0' - 9 3/4" 1' - 1 1/2" 7' - 6" GENERATOR PAD
FFE = 0'-0"
2' - 6" 2' - 6" 0' - 6"
0' - 6"
#4 BARS
PREPARED SUBGRADE,
SEE FOUNDATION NOTE 8
COORDINATE DIMENSIONS W/ EQUIPMENT SUPPLIER
EQUIPMENT
3/4" CHAMFER
CONC. FLOOR
/2
C L R
#4 BENT DOWELS W/ 3"
EMBED INTO FLOOR SLAB
AND 12" O.C. MAX. AROUND
PERIMETER
#4 BARS @
12" O.C., E.W.
TYP.
6"
6" SLAB ON
GRADE W/ 6X6 -
W2. 9XW2. 9 WWF
#4 @ 18" O.C.
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:5
:5
P
M
194SB-601
STRUCTURAL SECTIONS
PM CL
3/4" = 1'-0"194AS-101
B2
SECTION
3/4" = 1'-0"194AS-101
B4
SECTION
3/4" = 1'-0"194SB-101
D1
SECTION
3/4" = 1'-0"194SB-102
B7
SECTION
3/4" = 1'-0"194SB-101
B9
SECTION
3/4" = 1'-0"194SB-101
D3
SECTION
3/4" = 1'-0"194SB-101
D6
SECTION
3/4" = 1'-0"194SB-102
D5
SECTION
NTS194SB-102
D9
SECTION
1" = 1'-0"194SB-602
F1
SECTION
3/4" = 1'-0"194SB-101
F5
SECTION
3/4" = 1'-0"194SB-101
F3
SECTION
3/4" = 1'-0"
F7
SECTION
1" = 1'-0"194SB-102
F9
SECTION
NTS194SB-102
E9
SECTION
3/4" = 1'-0"194SB-102
A7
SECTION
4" GRANULAR FILL
VAPOR BARRIER
COMPACTED SOIL
SAW CUT & SEAL
6 x 6 - W2.9 x W2.9 WWF
CUT HALF WWF @ JOINTST
/4
T
SILENCER
GROUT AS NECESSARY
/2
CONT. L6x3x5/16
3/8" EPOXY BOLTS
W/ 4" EMBED @ 24" O.C.
ANCHOR CMU TO SLAB
W/ #4 DWLS x 9" LONG
@ 24" O.C. (3" EMBED.)
9' - 8"
5 1/2" 8' - 9"
5 1/2"
/8
/8
3/4" DIA. ANCHORS W/ 1'-0"
EMBED. (TYP. BOTH SIDES)
SEE DETAIL B8/194/SF-601
NOTE:
TANK FOUNDATION SIZE AND LOCATION TO BE COORDINATED WITH TANK MANUFACTURER.
9 #5 DWLS
#4 TIES @ 12" O.C.
7" 7"
/4
P2
F1
194SB-601 9 #5 DWLS
SET OF #4 TIES
(3 TIES/SET)
/4
1' - 0" 0' - 9 3/4" 0' - 7"
F1
194SB-601
P1
SIM
CURED CONC. NEW CONC.
VAPOR BARRIER
4" GRANULAR FILL
VAPOR BARRIER
COMPACTED SOIL
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:5
:5
P
M
194SB-602
STRUCTURAL DETAILS
PM CL
1 1/2" = 1'-0"194SB-602
A4
DETAIL
1 1/2" = 1'-0"194SB-602
A9
DETAIL
3/4" = 1'-0"194SB-602
A7
DETAIL
1" = 1'-0"194SB-602
A1
DETAIL
TABLE 1 - FOUNDATION AND PIER SCHEDULE
FOUNDATION PIER
Type Length Width Depth Reinf. B/Footing Elevation
Type Length Width DWL Ties T/Pier
F1 4'-3 3/4" 4'-3 3/4" 1'-0" 3'-0"
BELOW
GRADE
P1
DETAIL A2
DWG
194SB-602
1'-4 3/4" 9 #5 #4 @ 12" 6"
BELOW
FFE
F2 4'-0" 4'-3 3/4" 1'-0" P2
DETAIL A1
DWG
194SB-602
9 #5 #4 @ 12"1'-4 3/4"1'-2"
1'-4 3/4"
3'-0"
BELOW
GRADE
6"
BELOW
FFE
F3 5'-0" 5'-0" 1'-0" - - - --- 1'-6"
BELOW
GRADE
#4 @ 12" O.C.
BOTTOM
EACH WAY
1" = 1'-0"194SB-602
A2
DETAIL
1 1/2" = 1'-0"194SB-602
A5
DETAIL
#4 @ 12" O.C.
BOTTOM
EACH WAY
#4 @ 12" O.C.
BOTTOM
EACH WAY
A
DCB
W12X26 W14X30 W14X30
W X
W12X26
W X
W X
W X
W X
W X
W X
W X
W X
W X
W14X30 W14X30
W16X57 W16X57
W14X30
L O
W B
A Y
T
/S T
L E
L
/4
H
IG
H B
A Y
T
/S T
L E
L
W14X30
W14X30
TOP TOP
BOTTOM BOTTOM
1' - 5 3/8"
/8
1' - 5 3/8" 1' - 5 3/8"
/8
EDGE OF
DECKING
4" CONC. SLAB W/ 1.5 VL 22
GAGE COMPOSITE DECK
W/ 6X6 - W1.4X1.4 WWF
4" CONC. SLAB W/ 1.5 VL 22
GAGE COMPOSITE DECK
W/ 6X6 - W1.4X1.4 WWF
/8
B3
194SF-601
B1
194SF-601
10' - 0"
3 EQ. SPACES
21' - 10 5/8"
3 EQ. SPACES
21' - 10 5/8"
/4
/8
/8
B1
194SF-601
B5
194SF-601
B1
194SF-601
B5
194SF-601
B5
194SF-601
MC MOMENT CONNECTION
194SF-101F1
194SF-101
C5
194SF-101
E8
194SF-101
C8
W10X33
W10X33
W10X33
W10X33
W10X33
W10X33
W10X49
W10X39
W10X39
W8X24
W8X24 W8X24
W8X24
W8X24
W14X30
M C
M C
L3X3X1/4
L3X3X1/4
L3X3X1/4
M C
M C
M C
M C
M C
M C
M C M
C
P C
O F
W
X
(T Y
P
W X
W X
W X
W X
W X
W X
W X
W X
D O
D O
D O
D O
D O
EQ EQ
P C
(T Y
P
EQ EQ EQ EQ EQ EQ
E Q
E Q
P C
W8X10 W8X10 W8X10
W8X10 W8X10
W8X18 W8X10 W8X10 W8X10
E Q
E Q
M C
M C
BRACING POINT
D3
194SF-601
TYP. 10 PLACES
E Q
E Q
W8X10 W8X10 W8X10
W8X10W8X10 W8X10
W8X10 W8X10 W8X104
/4
D C
L5 X5X
5/
L5X5X5/16
SEE DETAIL
TYP.
194SF-601
D1
WP
T/STL = 22'-0"
FFE = 22'-0"
T/PIER = 0'- (-6)" 6
W
W
W14
ONE BOLT
CONNECTION
21' - 10 5/8"
3 4
L5 X5X
5/
SEE DETAIL
TYP.
194SF-601
B6
WPFFE = 0'-0"
T/PIER = 0'- (-6)"
T/STL = 11'-4"
W10
W
W
19' - 9 1/4"
L5X5X5/16
DC
L5X 5X
5/
W14X30
W14X30
W X
W X
SEE DETAIL
TYP.
194SF-601
D1
WP
WP
T/STL = 22'-0"
FFE = 0'-0"
T/PIER = 0'- (-6)"
T/STL = 11'-4"
21' - 10 5/8"
L5X5X5/16
L5 X5X
5/
L5X5X5/16
DC
194SF-601
B6
SEE DETAIL
TYP.
WP
T/STL = 11'-4"
W14
W
W
L5 X5X
5/
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:5
:0
P
M
194SF-101
STRUCURAL FRAMING PLAN AND
ELEVATIONS
PM CL
1/8" = 1'-0" C1
ROOF FRAMING PLAN
1/4" = 1'-0" C5
EAST ELEVATION
1/4" = 1'-0" F1
NORTH ELEVATION
1/4" = 1'-0" E8
ELEVATION
1/4" = 1'-0" C8
WEST ELEVATION
L3X3X1/4
1' - 5 3/8"
POUR STOP
W6
W12
T/STL = 11'-4"
W14
SEE ARCH.
0' - 9 3/4"
L3X3X1/4
W12
W6
POUR STOP
1' - 5 3/8"
SEE ARCH.
T/STL = 22'-0"
W14
POUR STOP
0' - 4 3/8"
W12
3" 3" 1"x10"x10" BASE
1 1/16" HOLE FOR 3/4" Ø
ANCHOR BOLT.
SEE DETAIL B7 FOR BOLT DETAIL
P R
O J
T H
D
/2
G R
O U
T
TACK
T/PIER
BASE PLATE
3/4" DIA. ANCHOR BOLT
SLOTTED HOLES IF REQUIRED
FOR BOLT CONNECTION
BACKING
BAR
TYPICAL MOMENT CONNECTION
SHEAR PL
BACKING
BAR
3" 3" 1"x12"x12" BASE
1 1/16" HOLE FOR 3/4" Ø
ANCHOR BOLT.
SEE DETAIL B7 FOR BOLT DETAIL
W8
W12 OR 14
1/4" PLATE
W12
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:5
:0
P
M
194SF-601
STRUCTURAL FRAMING SECTIONS
AND DETAILS
PM CL
3/4" = 1'-0"194SF-101
B1
SECTION
3/4" = 1'-0"194SF-101
B3
SECTION
3/4" = 1'-0"194SF-101
B5
SECTION
1 1/2" = 1'-0"194SF-601
B6
DETAIL
1 1/2" = 1'-0"194SF-601
B7
DETAIL NTS194SF-601
B8
DETAIL
1 1/2" = 1'-0"194SF-101
D1
DETAIL
NTS194SF-101
D3
SECTION
D N . 1
W P/
GF
TYP.
6'
- 0
7' - 0" 3
1LC5-C
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD
F F E I n c Engineering and Technical Services 110 Boggs Lane, Suite 170 Cincinnati, OH 45246 513-522-0956
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
EXPIRES 12/31/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 60
C :\U se rs
\ri le y\ D oc um en ts
\F
FE
_M ar io n_
M
EP
_B ui ld in g
(2
8) _r ile y.
ch ris to le ar
TR
L2 2.
rv t
5/
/2
2:
:4
PM
175AS-101
NEW WORK - BUILDING 175 -
LEVEL 1
PH BL
SCALE: 1/4" = 1'-0"
BUILDING 175 - POWER PLAN1
DRAWING NOTES
1 NEW 3’ X 7’ HOLLOW METAL DOOR WITH HOLLOW METAL FRAME. HARDWARE GROUP HW-R4.
2 NEW 3 5/8” METAL STUD WALL WITH 5/8” GYPSUM BOARD ON BOTH SIDES. EXTEND TO STRUCTURE ABOVE, APPROXIMATELY 20’.
3 ALIGN WITH EXISTING SURFACE
0' - 7 5/8"
INSULATED METAL
PANEL
BEAM OR ANGLES
(CENTER OF WALL)
HORIZ. JOINT REINF.
GROUT ALL CELLS SOLID
FULL LENGTH
#4 BAR x 6" LG. @ 16" O.C.
SOLID CMU
RIGID MASONRY TIES
@ 32" O.C. IN VERTICAL
JOINT
3/16
3/16
3-12
3-12
FLASHING
BUILDING 194
1' - 6"
0' - 1 1/8" 1' - 3 3/4" 0' - 1 1/8"
F1
194AS-201
D6
194AS-200
B A
T T
E R
Y S
Y S
T E
M
4' - 0"2' - 8"
/8
"3
18' - 9 1/4" 20' - 0" 18' - 6"
A
1' - 5 1/2"
/8
D
1' - 5 1/4"
C
53' - 9 1/4"
B
10' - 0"
/8
21' - 10 5/8" 21' - 10 5/8"
/8
/8
/8
/2
2 HOUR FIRE WALL
90 MIN. DOOR
B6
194AS-200
KNOCKOUT PANNEL FOR
FUTURE GENERATOR
90 MIN. WINDOW
/8
/8
/4
194AS-301
D6
SIM
/8
/2
/4
/8
46' - 8"
10' - 0"
56' - 8"
1' - 5 1/4"
/4
F1
194AS-201
D6
194AS-200
METAL GUTTER
A
DCB
B6
194AS-200
1/4" / 1'-0"1/4" / 1'-0"
/4
/4
1/4" / 1'-0"1/4" / 1'-0"
HIGH ROOF
LOW ROOF
CANAPY ROOFCANAPY ROOF
A
DCB
194AS-301
LOW ROOF BELOW
2 2
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
EXPIRES 12/31/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:0
:5
P
M
194AS-100
FLOOR PLAN
PH BL
1 1/2" = 1'-0" F1
LINTEL DETAIL
FOUNDATION PLAN NOTES:
1. CONTROL JOINT AND CONSTRUCTION JOINT LOCATIONS
ARE SHOWN FOR VISUAL REPRESENTATION ONLY.
FIELD LOCATE AT SPACING NOT TO EXCEED 30 TIMES
SLAB THICKNESS.
2. PIPE PENETRATIONS THRU FOUNDATION, PER DETAIL
ON 301S-501.
3. ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OR
PROPERLY COMPACTED FILL. SEE SPECIFICATIONS
SECTION 31 20 11 "EARTHWORK." COORDINATE WITH
CIVIL PLANS TO DETERMINE AMOUNT OF FILL
REQUIRED.
4. CONTRACTOR SHALL VERIFY DIMENSIONS WITH
ARCHITECTURAL PLANS ON SHEET 301A-101. NOTIFY
COR OF DISCREPANCIES.
5. FINISH FLOOR ELEVATION = 922.25. SEE CIVIL SHEETS
FOR FINISH FLOOR ELEVATION.
6. TOP OF FOOTING ELEVATION (T.O.F.) = -3'-0" BELOW
GRADE UNLESS NOTED OTHERWISE.
7. COORDINATE UTILITY LOCATIONS AND ELEVATION W/
CIVIL. FIELD VERIFY AT BUILDING FOUNDATION
LOCATIONS. REPORT ANY CONFLICTS TO COR.
8. O.C. - On Center O.H. - Over Head
REINFORCED CONCRETE FLOOR SLAB
MARK DESCRIPTION
SLAB-1
6" CONC. SLAB ON GRADE W/6X6 -W4.0XW4.0
WELDED WIRE FABRIC, TOP & BOTTOM, OVER 8" OF
COMPACTED GRANULAR FILL, TYP. U.N.O.
NOTES:
1. ALL LINTELS AT EXTERIOR LOCATIONS OR OTHERWISE
SUBJECT TO WEATHER OR A CORROSIVE ATMOSPHERE
SHALL BE GALVANIZED. LINTELS CONSISTING OF A PLATE
AND ROLLED BEAM W8 AND SMALLER SHALL HAVE BOTH
PLATE AND BEAM GALVANIZED AFTER WELDING. ALL
ANGLES SHALL BE GALVANIZED.
2. LINTELS UTILIZING BOTTOM PLATES SHALL HAVE PLATE
EXTENDED FULL LENGTH OF MASONARY OPENING ONLY.
BOTTOM PLATES SHALL NOT EXTEND INTO JAMBS OF WALL
OPENINGS.
3. LINTELS SHALL BEAR A MINIMUM OF 8" ON FULLY GROUTED
COURSES OF SOLID MASONRY. LINTELS SPANNING 8'-0" OR
MORE SHALL BEAR ON FULLY GROUTED CORES FULL
HEIGHT OF JAMB.
LINTEL SCHEDULE
SPAN WITH FACE BRICK
0 TO 6'-0"
DESCRIPTIONT
6'-0" TO 8'-0"
8'-1" TO 10'-0"
10"
10"
10"
(3) L4 x 4 x 5/16" W/ 3/8" x (W-1") WIDE PLATE
W8x10 & L4 x 3 1/2 x 5/16" (LLV) W/ 3/8" x (W-1")
WIDE PLATE
W8x15 & L5 x 3 1/2 x 5/16" (LLV) W/ 3/8" x (W-1")
WIDE PLATE
1 1/2" = 1'-0" F4
EXTERIOR SIGNAGE
1/8" = 1'-0" E1
FLOOR PLAN
1/8" = 1'-0"
E4
ROOF PLAN
1/8" = 1'-0"
LOW ROOF CLEARANCE FLOORPLAN
Revisions: Date:
ADDENDUM 4 11/23/2020
D6
194AS-200
F1
194AS-302
A
DCB
B6
194AS-200
/4
/2
BATTERY
SYSTEM
WORKING CLEARANCE
NEW SWITCHGEAR ON 6" TALL
CONCRETE PAD 6" WIDER THAN
SWITCHGEAR ON ALL SIDES
4' - 0"2' - 8"
1' - 5 1/2"
2 HOUR FIRE WALL
90 MIN. DOOR
GENERATOR
P
IP
E T
R E
N C
H P
IP
E
T R
E N
C H
8' - 8 1/4"
11' - 8 1/2"
10' - 0" 21' - 10 5/8" 21' - 10 5/8"
/8
/4
K
N O
C K
O U
T P
A N
E L
/2 "4
/8
/8
/8
/8
194AS-302
D3
194AS-302
D3
F5
194AS-300
F7
194AS-300
F4
194AS-300
F8
194AS-300
E6
194AS-101
/8
/8
/8
MATCHLINE MATCHLINE
2 2
DCB
SEE BOLLARD
DETAIL ON
191AS-3000
/2
194AS-302
D3
MATCHLINE MATCHLINE
TOP OF SLAB
0' - 0"
B
4' - 0"
4" HEAD
2' - 0" 1' - 4 3/4"
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
EXPIRES 12/31/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:0
:0
P
M
194AS-101
ENLARGED FLOOR PLANS
PH BL
1/4" = 1'-0" F1
ENLARGED GENERATOR FLOORPLAN
1/4" = 1'-0" D6
ENLARGED TANK STORAGE AREA
Door Schedule
Mark Height Type Width Door
Material Finish Frame Type
Frame Material
Hardware Set
Fire Rating Details Head Details Jamb Details Sill Comments
001 7' - 0" A 3' - 0" HOLLOW
METAL
PAINTED F-1 HOLLOW
METAL
HW-E1 N.A. F1 ON AS-300 F1 ON AS-300 FA ON AS-300
002 7' - 0" A 6' - 0" HOLLOW
METAL
PAINTED F-1 HOLLOW
METAL
HW-E6 N.A. F1 ON AS-300 F1 ON AS-300 FA ON AS-300
003 7' - 0" A 3' - 0" HOLLOW
METAL
PAINTED F-1 HOLLOW
METAL
HW-R4 90
MIN.
F1 ON AS-300 F1 ON AS-300 FA ON AS-300
004 8' - 0" A 6' - 0" HOLLOW
METAL
PAINTED F-1 HOLLOW
METAL
HW-E6 N.A. F1 ON AS-300 F1 ON AS-300 FA ON AS-300
005 7' - 0" A 6' - 0" HOLLOW
METAL
PAINTED F-1 HOLLOW
METAL
HW-E6 N.A. F1 ON AS-300 F1 ON AS-300 FA ON AS-300
006 7' - 0" A 3' - 0" HOLLOW
METAL
PAINTED F-1 HOLLOW
METAL
HW-E1 N.A. F1 ON AS-300 F1 ON AS-300 FA ON AS-300
1/4" = 1'-0" E6
WINDOW ELEVATION
MATCHLINE
Revisions: Date:
TOP OF SLAB
0' - 0"
LOW ROOF
CLEARANCE
10' - 0"
FOUNDATION
-2' - 0"
LIGHT FIXTURE SEE
ELECTRICAL DRAWING
CARD READER
ROOF CANOPY
LIGHT FIXTURE SEE
ELECTRICAL DRAWING
CARD READER
A
D C
HIGH ROOF
CLEARANCE
22' - 0"
B
METAL COPING
B1
B1
KEY PLAN
A
DCB
TOP OF SLAB
0' - 0"
LOW ROOF
CLEARANCE
10' - 0"
FOUNDATION
-2' - 0"
METAL DOWNSPOUT
METAL COPING
SPLASH BLOCK
ROOFTOP UNIT
SEE MECHANICAL DRAWING
ROOF CANOPY
LIGHT FIXTURE SEE
ELECTRICAL DRAWING
CARD READER
ROOF CANOPY
LIGHT FIXTURE SEE
ELECTRICAL DRAWING
CARD READER
A DC
HIGH ROOF
CLEARANCE
22' - 0"
B
21' - 10 5/8"21' - 10 5/8"
METAL GUTTER
METAL GUTTER
TOP OF SLAB
0' - 0"
LOW ROOF
CLEARANCE
10' - 0"
FOUNDATION
-2' - 0"
SWITCHGEAR
A DCB
194AS-300
F8
TOP OF SLAB
0' - 0"
LOW ROOF
CLEARANCE
10' - 0"
F1
194AS-201
FOUNDATION
-2' - 0"
DC
HIGH ROOF
CLEARANCE
22' - 0"
B
194AS-300
F7
1/4" / 1'-0"1/4" / 1'-0"
/2
194AS-300
F4
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
EXPIRES 12/31/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:0
:0
P
M
194AS-200
ELEVATIONS AND SECTIONS
PH BL
1/4" = 1'-0" B1
EXTERIOR ELEVATION EAST
1/4" = 1'-0" D1
EXTERIOR ELEVATION WEST
1/4" = 1'-0"
D6
BUILDING SECTION SOUTH
1/4" = 1'-0" B6
BUILDING SECTION AT LOUVERS
LOW ROOF
CLEARANCE
10' - 0"
FOUNDATION
-2' - 0"
ROOFTOP UNIT
SEE MECHANICAL
DRAWING
ROOF CANOPY
LIGHT FIXTURE SEE
ELECTRICAL DRAWING
SPLASH BLOCK
METAL GUTTER
SPLASH BLOCK
CARD READER
DOWNSPOUT
METAL GUTTER
DOWNSPOUT
EXTERIOR SIGNAGE SEE
DETAIL F4 ON AS-100
3 12
HIGH ROOF
CLEARANCE
22' - 0"
JOINTS IN METAL PANEL
FOR FUTURE LOUVER
EXHAUST PIPING
FROM GENERATOR
SEE MECHANICAL
DRAWINGS
WALL MOUNTED
EXHAUST FAN
SEE MECHANICAL
DRAWINGS
TOP OF SLAB
0' - 0"
LOW ROOF
CLEARANCE
10' - 0"
FOUNDATION
-2' - 0"
ROOF CANOPY
LIGHT FIXTURE SEE
ELECTRICAL DRAWING
CARD READER
DOWNSPOUT
SPLASH BLOCK
DOWNSPOUT
SPLASH BLOCK
GUTTER
METAL GUTTER
EXTERIOR SIGNAGE SEE
DETAIL F4 ON 194AS-100
ROOFTOP UNIT-
SEE MECHANICAL
DRAWINGS
31 2
HIGH ROOF
CLEARANCE
22' - 0"
DOWNSPOUT
SPLASH BLOCK
METAL COPING METAL COPING
A
DCB
KEY PLAN
TOP OF SLAB
0' - 0"
LOW ROOF
CLEARANCE
10' - 0"
FOUNDATION
-2' - 0"
194AS-300
F8
SWITCHGEAR
CAST IN PLACE
CONCRETE SLAB
SEE DETAIL 5 ON SS-101
HIGH ROOF
CLEARANCE
22' - 0"
B6
194AS-200
194AS-300
F1
194AS-300
C8
E6
194AS-101
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
EXPIRES 12/31/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:0
:1
P
M
194AS-201
ELEVATION AND SECTIONS
PH BL
1/4" = 1'-0" B1
EXTERIOR ELEVATION SOUTH
1/4" = 1'-0" D1
EXTERIOR ELEVATION NORTH
1/4" = 1'-0" F1
BUILDING SECTION WEST
FOUNDATION
-2' - 0"
HIGH ROOF
CLEARANCE
22' - 0"
FOOTING
2" RIGID INSULATION
FOUNDATION WALL
CONCRETE SLAB
METAL FLASHING
INSULATED METAL
PANEL ON METAL
HAT CHANNELS
KEE ROOFING
ON INSULATION
ON CONCRETE/
METAL DECKING
METAL GRAVEL
STOP
STEEL BEAM
POUR STOP
1' - 5 3/8"
194AS-301
F9
194AS-301
D9
7/8" 1' - 5 3/8" 2 3/4"
8" CMU - SEE PLAN
FOR VERTICAL REINFORCING
HORIZONTAL REINFORCING
PER SPECIFICATIONS
TOP OF SLAB
0' - 0"
FOUNDATION
-2' - 0"
D
HIGH ROOF
CLEARANCE
22' - 0"
KEE ROOFING
ON TAPERED
INSULATION
ON CONCRETE/
METAL DECKING
METAL GRAVEL
STOP
STEEL BEAM
POUR STOP
GUTTER
1' - 5 3/8"
194AS-301
F6
2 3/4"
7/8"
1' - 5 3/8"
194AS-301
F9
6" DEEP LOUVER
SEE MECHANICAL
DRAWINGS
SILL FLASHING
THRU WALL
FLASHING
W8x18 BEAM
8" BEARING
EACH END
3/8" x 7 5/8"
BOTTOM PLATE
SEAL ALL SIDES
OF LOUVER
SEAL ALL SIDES OF
LOUVER
INSULATED METAL
PANEL ON METAL
HAT CHANNELS
8" CMU - SEE PLAN
FOR VERTICAL REINFORCING
HORIZONTAL REINFORCING
PER SPECIFICATIONS
VOLUME CONTROL
DAMPER - SEE
MECHANICAL
DRAWINGS
6" DEEP LOUVER
SEE MECHANICAL
DRAWINGS
VOLUME CONTROL
DAMPER - SEE
MECHANICAL
DRAWINGS
STEEL ANGLE
AROUND
VCD AS REQUIRED
FOR SUPPORT
STEEL ANGLE
AROUND
VCD AS REQUIRED
FOR SUPPORT
LOW ROOF
CLEARANCE
10' - 0"
HIGH ROOF
CLEARANCE
22' - 0"
KEE ROOFING ON
TAPERED INSULATION
ON CONCRETE/METAL
DECK
INSULATED METAL
PANELS
METAL COPING
STEEL BEAM
KEE ROOFING ON
TAPERED INSULATION
ON CONCRETE/METAL
DECK
6" STUDS IN LINE
WITH DIAGONAL
BRACING - TIE
BACK TO CMU
AS REQUIRED
FLASHING
4 3/8"
EDGE OF SLAB
EDGE OF SLAB
A
DCB
F1
194AS-300
F8
194AS-300
C8
194AS-300
SCREEN WALL - SHORT
REINFORCING
#6 BARS 32" O.C.
HIGH BAY WALLS TYPE 1
#5 BARS 16" O.C.
LOW BAY WALLS
#4 BARS 32" OC.
F5
194AS-300
F4
194AS-300
F4
194AS-300
F7
194AS-300
F8
194AS-300
INTAKE LOUVER
INTAKE LOUVER
KNOCKOUT PANEL
EXHAUST LOUVER
F8
194AS-300
SCREEN WALL - LONG
REINFORCING
#6 BARS 40" O.C.
GENERAL NOTES:
1. ALL REBAR VERTICAL
2. GROUT CELLS WITH REBAR SOLID
HIGH BAY TYPICAL
#4 BARS 16" O.C.
HIGH BAY TYPICAL
#4 BARS 16" O.C.
HIGH BAY WALLS TYPE 1
#5 BARS 16" O.C.
TWO ROWS OF #5 BARS
AT 8" O.C.
HIGH BAY TYPICAL
#4 BARS 16" O.C.
HIGH BAY TYPICAL
#4 BARS 16" O.C.
HIGH BAY TYPICAL
#4 BARS 16" O.C.
TOP OF SLAB
0' - 0"
FOUNDATION
-2' - 0"
HIGH ROOF
CLEARANCE
22' - 0"
B
1' - 5 3/8"
7/8"
2 3/4"
VOLUME
CONTROL
DAMPER -
SEE MECHANICAL
DRAWINGS
INTAKE
LOUVER
SEE MECHANICAL
DRAWINGS
194AS-301
F9
FLASHING
SEAL PERIMETER
OF LOUVER
VOLUME
CONTROL
DAMPER -
SEE MECHANICAL
DRAWINGS
INTAKE
LOUVER
SEE MECHANICAL
DRAWINGS
THRU WALL
FLASHING
STEEL ANGLE
AROUND
VCD AS REQUIRED
FOR SUPPORT
SEE PLAN FOR
VERTICAL
REINFORCING
SEAL PERIMETER
OF LOUVER
W8x18 BEAM
8" BEARING
EACH END
3/8" x 7 5/8"
BOTTOM PLATE
TOP OF SLAB
0' - 0"
FOUNDATION
-2' - 0"
D
HIGH ROOF
CLEARANCE
22' - 0"
KEE ROOFING
ON TAPERED
INSULATION
ON CONCRETE/
METAL DECKING
METAL GRAVEL
STOP
STEEL BEAM
POUR STOP
GUTTER
1' - 5 3/8"
194AS-301
F6
2 3/4"
7/8"
1' - 5 3/8"
194AS-301
F9
KNOCK OUT PANEL
FOR FUTURE
LOUVER
THRU WALL
FLASHING
PANEL JOINT
SEAL
PANEL
JOINT,
SEAL
INSULATED METAL
PANEL ON METAL
HAT CHANNELS
W8x18 BEAM
8" BEARING
EACH END
3/8" x 7 5/8"
BOTTOM PLATE
TOP OF SLAB
0' - 0"
LOW ROOF
CLEARANCE
10' - 0"
FOUNDATION
-2' - 0"CONCRETE
FOUNDATION
CONCRETE
FOUNDATION
WALL
CMU
WALL
INSULATED
METAL WALL
PANEL ON
STEEL HAT
CHANNELS
GRAVEL
FILL
2x16
TREATED
WOOD
BLOCKING
SEAL
EXPOSED
CMU
P: 937-224-0861 www.heapy.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Marion VA Marion, IN
#610-16-104
PROJECT NO. 2018-05034
CONSTRUCTION DOCUMENTS
04/29/2020
EXPIRES 12/31/2020
UPGRADE EMERGENCY
POWER IN BUILDING 138
DRAWING OF 61
C R e v it U s e r F ile s \F
F E
M a ri o n
B u ild in g s w it c h p a tr ic k .h ill ie r@ ff e
-s e rv
.c o m
.r v t
/2
/2
:0
:2
P
M
194AS-300
WALL SECTIONS
PH BL
3/4" = 1'-0" F8
WALL SECTION - EAST WALL
3/4" = 1'-0" F7
WALL SECTION - GENERATOR
3/4" = 1'-0" C8
HIGH LOW ROOF DETAIL
3/32" = 1'-0" D1
WALL SECTION KEY PLAN
3/4" = 1'-0" F4
WALL SECTION - INTAKE
3/4" = 1'-0"
F5
WALL SECTION - K.O. PANEL
3/4" = 1'-0" F1
WALL SECTION - SCREEN WALL
Revisions: Date:
1 1 1
WALL
DUCT
PIPE
SLEEVE
STEP 1: FILL GAP AROUND PIPE/DUCT
SLEEVE WITH FOAM.
STEP 2: APPLY URETHANE SEALANT
AROUND PENETRATION.
WALL
DUCT
PIPE
STEP 3: CUT SHEET METAL TRIM FOR LOWER
AND UPPER HALVES OF OPENING AND
ATTACH USING 1/8" PAINTED STAINLESS
STEEL POP RIVETS. TRIM SHALL MATCH
THE REST OF THE WALL.
NOTE:
1. THIS DETAIL IS FOR REFERENCE, SEAL IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS.
0' - 9"
1' - 0"
NOTES:
1. POST BARRICADES SHALL BE PAINTED WITH ONE PRIME COAT OF RED
OXIDE. ONE FINISH COAT OF DULL BLACK ENAMEL PER VA SPECIFICATIONS
AND STRIPES CONSISTING OF 4" BANDS OF YELLOW REFLECTORIZED TAPE
SHALL BE USED UNLESS OTHERWISE SPECIFIED ON THE PLANS.
2. FINISH COLOR COMBINATIONS, OTHER THAN THAT SPECIFIED ABOVE, SHALL
BE SUBMITTED TO THE AGENCY FOR APPROVAL.
3. TYPE A. UNLESS NOTED OTHERWISE.
UTILITY CONCRETE
PER VA
SPECIFICATIONS
3"Ø x 5'-0"
STANDARD PIPE
POST BARRICADE
CONCRETE FILLED
5"Ø x 7'-0"
STANDARD PIPE
POST BARRICADE
CONCRETE FILLED
5' O.C.
TYPE "A"
TYPE "B"
PRESSURE TREATED
WOOD BLOCKING
JAMB DETAIL - TYPICAL
CONCRETE SLAB,
SEE STRUCTURAL
DRAWINGS FOR
DETAILS
EXPANSION MATERIAL
METAL THRESHOLD,
SET IN SEALANT
HOLLOW METAL DOOR
HOLLOW METAL DOOR FRAME
HEAD DETAIL - TYPICAL
BOND BEAM W (2) #5
BARS IN GROUT
8" BEARING AT…