Attachment IV - Drawings Set rev w Changes Summary.pdf
PDF 14 MB Posted
- Attached to
- Y1AZ--Renovate Bldg. 15, 2nd Floor
- Solicitation number
- 36C24625B0007
About this file
This document is a detailed set of architectural drawings for the renovation of Building 15, 2nd Floor at the Charles George VA Medical Center in Asheville, North Carolina. The project involves comprehensive interior renovation of approximately 11,291 square feet, including demolition of existing spaces, asbestos abatement, and reconstruction of office, restroom, and support areas. Key technical details include phased construction with Infection Control Risk Assessment (ICRA) barriers, renovation of existing business occupancy spaces, and compliance with NFPA 101 Life Safety Code and VA fire protection design standards.
The drawings, dated February 9, 2024, with an addendum on April 1, 2025, cover multiple disciplinary aspects including architectural, electrical, mechanical, plumbing, telecommunications, and fire alarm systems. The renovation project is specifically identified as VA Project Number 637-20-103, with a solicitation number of 36C24625B0007. The design professional is ODELL, A LaBella Company, located in Asheville, NC, and the project involves detailed floor plan modifications, ceiling replacements, wall reconfigurations, and infrastructure updates across the second floor of the medical center building.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
April 1, 2025 VAMC ASHNC – BLDG 15, 2nd FLOOR – PN 637-20-103 Page 1 of 1
Date: April 1, 2025
DRAWING CHANGE SUMMARY
VAMC, ASHEVILLE, NC
RENOVATE BUILDING 15, 2nd FLOOR
PROJECT NUMBER: 637-20-103
DRAWING UPDATED Addendum Number
Date
GI004 Update to type A from type B 1 4/1/2025
GI004 Added ICRA wall in front of MACPAC 1 4/1/2025
A101 Addition to Keynote A3 - Estimate Sq Ft for patching and restoring applied Fireproofing at 30 SQ FT plus or minus 10%.
1 4/1/2025
A102 RCP Graphic Legend – Removed legend graphic for window blinds as there are not any.
1 4/1/2025
A201 Deletion from Keynote A4 - remove digital graphics
1 4/1/2025
A201 Addition to Keynote A13 - Maximum Pitch on slope to drain is 1/8" per foot.
1 4/1/2025
A201 Update drawings to remove notes of Level 5 finish. 1 4/1/2025
A201 Addition to Keynote A11 - Please reference UL detail C-AJ-0070 for basis of design for floor infill detail.
1 4/1/2025
A701 Keyed details C1 and C2 ceiling details. 1 4/1/2025
A701 Removed EC1 (EPOXY PAINT) from Interior Finish Legend.
1 4/1/2025
A701 Relabeled flooring finish SF1 with LVT1. 1 4/1/2025
T101 Added MS to the sheet Legend 1 4/1/2025
SITE KEY PLAN
AREA OF WORK
PROJECT INFORMATION
PROJECT ADDRESS
CHARLES GEORGE VA MEDICAL CENTER
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
DESIGN PROFESSIONAL:
ARCHITECTURAL ODELL, A LABELLA COMPANY MICHAEL C. MONTGOMERY 012055 LIC. NO. 828-579-4426
ELECTRICAL CHARLOTTE ENGINEERS NICHOLAS G. ESPOSITO 054276 LIC. NO 704-531-3000
FIRE ALARM CHARLOTTE ENGINEERS JOHN RICHARD CALLAHAN 031042 LIC. NO 704-531-3000
PLUMBING CHARLOTTE ENGINEERS GREGORY A. TURNER 031465 LIC. NO 704-531-3000
MECHANICAL CHARLOTTE ENGINEERS GREGORY A. TURNER 031465 LIC. NO 704-531-3000
OCCUPANCY TYPE: EXISTING BUSINESS
CODES:
NFPA 10 - STANDARD FOR PORTABLE FIRE EXTINGUISHERS
NFPA 13 - STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
NFPA 101 - LIFE SAFETY CODE
NFPA 5000 - BUILDING CONSTRUCTION AND SAFETY CODE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% SUBMISSION
NON-SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
NORTH
# 637-20-103
# 15
ASHEVILLE VA MEDICAL CENTER
ARCHITECT OF RECORD
A/E:
CONSULTANT
Engineering discipline:
Charlotte Engineers 5838 Monroe Rd # 100, Charlotte, NC 28212 704-531-3000 Esther Moallen Douglas Ehlers, P.E
ODELL, A LaBella Company 795 Haywood Road Asheville, NC 28806 828-579-4426 Denice Regino / Michael Montgomery
PROGRAM MANAGER
Program manager:
Odell International 129 Fast Lane, Suite 200 Mooresville, NC 28117 704-401-2050 Richard Cantwell
B
IM
/4
-0
V A
A s h e v ill e -B u ild in g
R e n o v a ti o n s /4
-0
V
A A s h e v ill e B ld g n d F lo o r R e n o
A
R C
H
.r v t
/8
/2
:3
:5 P
M
GI001
COVER & SHEET INDEX
Approver
02/09/2024 DR SL
PROJECT NUMBER: PROJECT DATE:
ARCHITECTURAL INTERIORS
MECHANICAL PLUMBING ELECTRICAL FIRE PROTECTION
RENOVATE BUILDING 15, 2ND FLOOR
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
100% SUBMISSION
4380-001 02/09/2024
SHEET INDEX - FIRE ALARM
Sheet Number Sheet Name Sheet Issue
Date Current Revision
Current Revision Date
Current Revision Description
FA001 FIRE ALARM - SYMBOLS, NOTES & DRAWING INDEX 02/09/24
FA002 FIRE ALARM - DETAILS 02/09/24
FA003 FIRE ALARM INPUT/OUTPUT MATRIX & INTERIM REQMTS. 02/09/24
FA101 FIRE ALARM - SECOND FLOOR - NEW WORK 02/09/24
FAD101 FIRE ALARM - SECOND FLOOR - DEMOLITION 02/09/24
SHEET INDEX - GENERAL
Sheet Number Sheet Name Sheet Issue
Date Current Revision
Current Revision Date
Current Revision Description
GI001 COVER & SHEET INDEX 02/09/24
GI002 CODE ANALYSIS 02/09/24
GI003 LIFE SAFETY PLAN - SECOND FLOOR 02/09/24
GI004 SECOND FLOOR ICRA AND PHASING PLAN 02/09/24
GI005 SECOND FLOOR ASBESTOS ABATEMENT PLAN 02/09/24
SHEET INDEX - PLUMBING
Sheet Number Sheet Name Sheet Issue
Date Current Revision
Current Revision Date
Current Revision Description
P001 PLUMBING - SYMBOLS, NOTES, DRAWING INDEX, & DETAILS 02/09/24
P101 PLUMBING - SECOND FLOOR - NEW WORK 02/09/24
PD101 PLUMBING - SECOND FLOOR - DEMOLITION 02/09/24
SHEET INDEX - ELECTRICAL
Sheet Number Sheet Name Sheet Issue
Date Current Revision
Current Revision Date
Current Revision Description
E001 ELECTRICAL - SYMBOLS, NOTES & DRAWING INDEX 02/09/24
E002 ELECTRICAL - DETAILS 02/09/24
E003 ELECTRICAL - RISER DIAGRAM & LUMINAIRE SCHEDULE 02/09/24
E004 ELECTRICAL - SCHEDULES 02/09/24
ED101 ELECTRICAL - SECOND FLOOR - DEMOLITION 02/09/24
EL101 ELECTRICAL - SECOND FLOOR - NEW WORK - LIGHTING 02/09/24
EP101 ELECTRICAL - SECOND FLOOR - NEW WORK - POWER 02/09/24
SHEET INDEX - TELECOM
Sheet Number Sheet Name Sheet Issue
Date Current Revision
Current Revision Date
Current Revision Description
T001 TELECOMMUNICATIONS - SYMBOLS, NOTES & DWG INDEX 02/09/24
T002 TELECOMMUNICATIONS - DETAILS 02/09/24
T101 TELECOMMUNICATIONS - SECOND FLOOR - NEW WORK 02/09/24
TD101 TELECOMMUNICATIONS - SECOND FLOOR - DEMOLITION 02/09/24
SHEET INDEX - MECHANICAL
Sheet Number Sheet Name Sheet Issue
Date Current Revision
Current Revision Date
Current Revision Description
M001 MECHANICAL - SYMBOLS, NOTES AND DRAWING INDEX 02/09/24
M002 MECHANICAL - SCHEDULES AND DETAILS 02/09/24
MD101 MECHANICAL - SECOND FLOOR - DEMOLITION - AREA A 02/09/24
MD102 MECHANICAL - SECOND FLOOR - DEMOLITION - AREA B 02/09/24
MH101 MECHANICAL - SECOND FLOOR - NEW WORK - AREA A 02/09/24
MH102 MECHANICAL - SECOND FLOOR - NEW WORK - AREA B 02/09/24
SHEET INDEX - ARCHITECTURAL
Sheet Number Sheet Name Sheet Issue
Date Current Revision
Current Revision Date
Current Revision Description
A100 ARCHITECTURAL NOTES, SYMBOLS & ABBREVIATIONS 02/09/24
A101 SECOND FLOOR DEMO PLAN 02/09/24
A201 SECOND FLOOR PLAN & RCP - NEW WORK 02/09/24
A401 INTERIOR ELEVATIONS AND DETAILS 02/09/24
A450 ENLARGED TOILET PLAN AND STANDARDS 02/09/24
A501 INTERIOR PARTITION TYPES 02/09/24
A601 INTERIOR DOOR AND FRAME SCHEDULE 02/09/24
A701 SECOND FLOOR - FINISH PLAN AND NOTES 02/09/24
A801 SECOND FLOOR - FURNITURE PLAN (By Vendor) 02/09/24
Revisions: Date:
PROJECT IMAGE
2/9/2024
CODE REVIEW INFORMATION
NFPA 101 LIFE SAFETY CODE 2021
VA FIRE PROTECTION DESIGN MANUAL
BUILDING DATA FIRE RESISTANCE RATINGS - IIB(211)
NFPA REQ'D PROVIDED
USE DESCRIP TION EX ISTING BUSINESS
OCCUPAN CY
NFPA CH. 39 (6.1.1)
MIXED OCCUPANCY
NFPA CH. 6 (6.1.14)
NFPA REQ'D PROVIDED
NA
CLASS IF ICATION OF WORK
NFPA CH. 4 (4.6.7)
CONSTRU CTIO N TYPE NFPA 220 TABLE 4.1.1 TYPE IIB ( 211)
NO. OF S TORIES
TOTAL PR OJECT AR EA
NUMBER OF OCCUPANTS
MIN. NU MBER OF EX ITS
MIN. EX IT WIDTH PER OCC.
MIN. DOO R WIDTH
(REFER TO LIFE SAFETY PLAN)
MIN. STA IRWAY WI DTH
ONE EX IT R ULES
MIN. CO RRIDOR WIDTH
MAX. TR AVEL DI STANCE
MAX. CO MMO N PATH OF TRAVEL
MAX. D EAD END COR RIDOR
CON CEALED SPACE DRAFTSTO PPI NG
SMO KE COM PARTMENT
INTERI OR F IN ISHES CLASS
INTERIOR EXIT STAIRWAYS, RAMPS AND EXIT
PASSAGEWAYS
(REFER TO LIFE SAFETY PLAN)
(REFER TO LIFE SAFETY PLAN)
CORRIDORS AND ENCLOSURE FOR EXIT ACCESS
STAIRWAYS AND RAMPS
ROOMS AND ENCLOSED SPACES
AUTO MAT IC SPR INKLER SYSTEM
FIRE EX TINGUI SHER SPACING
STAN DPI PE SYSTEM
SMOKE AND F IR E DETECT ION
FIRE ALARM SYSTEM
VERT ICAL ACCESS REQ UIR ED
ACCESSI BLE EN TR AN CE
PASSENGER LO ADIN G ZO NES
ABBREVIATI ONS:
N/A
NC
C
NR
B
STRU CTUR AL DESI GN:
REFER TO SPEC IF IC DRAWING AND SPECI F ICATION SECT IONS FOR
ADDIT IONAL STR UCTUR AL D ESIGN CRITERIA INCLUDIN G BUT NOT
LIMI TED TO, LIVE LOAD, D EAD LOAD , AN D LATERAL LO ADS
APPL ICABLE TO THI S PR OJECT.
NOT APPL ICABLE / NO T PART O F THIS PROJ ECT
NON-COM BUSTIB LE
COM BUSTIB LE
NOT REQ UIRED
BARRI ER TO LIMIT TRANS FER OF SMOKE
CONTR ACTO R TO VERI FY /
MAINTA IN / PATCH ANY
AND ALL AR EAS OF
FIREPROOFING OR UL
ASSEMBL IES WITHIN
SCO PE OF WO RK
NOTES:
BUILDING ELEMENT TABLE
PRIM ARY STR UCTURAL FR AME
EXTERIO R BEAR ING WALLS
SUPPORTING MORE THAN ONE FLOOR, COLUMNS,
OR OTHER BEARING WALLS
SUPPORTING ONE FLOOR ONLY
SUPPORTING A ROOF ONLY
INTERIOR BEARIN G WALLS
SUPPORTING MORE THAN ONE FLOOR, COLUMNS,
OR OTHER BEARING WALLS
SUPPORTING ONE FLOOR ONLY
SUPPORTING A ROOF ONLY
COLU MNS
SUPPORTING MORE THAN ONE FLOOR, COLUMNS,
OR OTHER BEARING WALLS
SUPPORTING ONE FLOOR ONLY
SUPPORTING A ROOF ONLY
BEAM S, G IRD ERS, TR USSES, AND ARCHES
SUPPORTING MORE THAN ONE FLOOR, COLUMNS,
OR OTHER BEARING WALLS
SUPPORTING ONE FLOOR ONLY
SUPPORTING A ROOF ONLY
FLOOR -CEI LING ASSEMBL IES
ROOF -CEI LING ASSEMBL IES
INTER IOR NON-BEARI NG WALLS
EXTERIOR NON -BEARIN G WALLS
FLOOR CONSTRUCTION AND ASSOCIATED
SECONDARY MEMBERS
ROOF CONSTRUCTION AND ASSOCIATED
SECONDARY MEMBERS
FIRE WALLS
FIRE BARRIERS
FIRE PAR TITIONS
VERT ICAL EX IT ENCLOSURE
EX I T PASSAGEWAY
HORIZ ONTAL EX IT SEPARATION
INCI DEN TAL USE AR EAS
OCCUPANCY SEPAR ATI ON
SHAF T ENCLOSU RE
COR RID OR WALLS
SMOKE BARRI ERS
FIRE PR OOFING ASSEM BLIES:
BEAM S, COLU MNS , FLOOR SY STEM , R OOF SYSTEM
1. REFER TO CO DE COMPLIANCE & L IFE SAF ETY
PLANS FO R ADDIT IONAL I NFORMAT ION ON
EGRESS, P ARTIT ION RATI NGS AND O THER
CODE RELATED INFO RMAT ION.
NFPA TABLE 32.3.1.3
NFPA TABLE 7.3.1.2
NFPA 7.4.1.2 / 39.2.4.1
NFPA 7.4
NFPA 7.3.3.1
NFPA 39.2.2.2.1
7.2.1.2.3.2
MAX 3 EX IST. 3 STORIES (55 ')
SUITE = +/-11,291 SF
2 MIN. COMPLIES (4)
N/A N/A
0.3 STAIRS
0.2 OTHER
NFPA 39.2.2.3.1/
TABLE 7.2.2.1 (b) EXISTING STAIRS 36"
NFPA 39.2.3.2
44" CLEAR COM PLI ES
NFPA 39.2.6.2 / TABLE A7.6 COMPLIES
(SEE LIFE SAFETY PLAN)
NFPA 39.2.5.2.3 / A7.6
75 ' MAX
NFPA TABLE A7.6 /
(SEE LIFE SAFETY PLAN)
NFPA 8.6.11
N/A N/A
NFPA 39.3.7
NFPA 39.3.3.2.1
COM PLI ES
NFPA 32.2.3.5.1
YES NO
(SEE LIFE SAFETY PLAN)
NFPA 32.3.3.8 / 9.9
NFPA 9.10.1
YES NO
NFPA 9.6
YES NO
NFPA 9.6
YES NO
YES
YES
CONSTR UCTION SHALL CONF ORM TO CURR ENT AN D IN- FORCE EDITIO NS OF NFPA 101 L IFE SAFETY CODE ( 2021 ED.), NFPA 7 0 Nati onal Electr ic Code, NATIONAL STAN DARD P LUMBI NG COD E, NAT IONAL F IRE ALARM COD E, AS WELL AS ALL OTH ER LOCAL, STATE AN D F EDERAL CO DES AN D R EGU LAT ION S R EFEREN CE IN THE V.A. DES IGN STAND ARD S M ANU AL. WHER E CONF LICTS OCCUR BETWEEN CODES AND STANDARDS , THE V.A. SHALL BE NO TIF IED AND A RESOLUT ION WILL B E MADE BY THE V.A.'S AUTHO RITY HAVIN G JUR ISDICTION.
EX ISTING
EX ISTING
EX ISTING
NFPA TABLE A8.2.1.2
NFPA 7.1.3.2
NFPA 7.2.6
2 HR / 1 HR
NFPA 7.2.4
N/A N/A
NFPA TABLE 32.3.3.2.2
NFPA 6.1.14
NFPA 8.6.5
2 HR ≥ 4 STORIES
1 HR < 4 STORIES
2 HR ≥ 4 STORIES
1 HR < 4 STORIES
NFPA 32.3.3.6
NFPA 32.3.3.7.9
EXISTING BUSINESS (B)
NO
RENO VAT IO N ( N O CH ANG E TO
OCCU PAN CY, USE O R EGR ESS)
50 ' MAX
200 ' MAX
EX ISTING
32"
NO SPECIAL
REQUIREMENTS
75' ; 1/3,000 SF
2HR
2 HR
2HR
3 HR
3 HR
2 HR
1 HR
1 HR
1 HR
1 HR
1 HR
1 HR
1 HR
1 HR
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
FLOO R & ROOF ASSEMBL IES
NFPA TABLE A8.2.1.2
ELEVATOR LOBBY NFPA 7.2.13 (TOWERS) / 7.15.1.1
CLASS A OR B
EX ISTING
1 HR
COM PLI ES
COM PLI ES
150 SF/PERSON 11,291 SF / 150 = 75 OCC.
75 X .3 = 22.5" 75 X .2 =15"
COM PLI ES
EXISTING
COMPLIES
NON- SPRINKLERED
EXCEPT FOR ATTIC
39.2.5.3
(SEE LIFE SAFETY PLAN)
IBC 2021 TABLE 506.2
TOTAL BUI LDIN G AR EA ( IBC) 23 ,000 SF / FLOOR EXISTING +/-11,291 SF
(ACTUAL SUITE AREA)
EXISTING 4 1/2"
CONCRETE SLAB
EX ISTING BUSINESS
EXISTING BUSINESS (B)
RENO VAT IO N ( N O CH ANG E TO
OCCU PAN CY, USE O R EGR ESS)
CLASS A OR B
CLASS A , B OR C
N/A
EX ISTING
1. MAIN STRUCTUR AL FRAME IS CON CRETE
COLUM NS AND F LOOR CON STRU CTIO N. R OOF
CONSTRUCT ION IS WOOD
FRAMED WI TH F IRE SPRIN KLER PRO TECT ION.
2. MASO NRY FACE BRICK WI TH M ASO NRY
BACK -UP STU CCO SID ING OVER F ACE BRI CK.
3. NON-STR UCTU RAL METAL STU D FR AMI NG.
1 HR
EX ISTING
1 HR
1 HR
EX ISTING
EX ISTING
EX ISTING
EX ISTING
EX ISTING
N/A N/A
N/A N/A
EX ISTING
N/A N/A
N/A N/A
EX ISTING
A-A A-A11,291 SF
VERTICAL CIRCULATION
1ST FLOOR
2ND FLOOR
3RD FLOOR
BUSINESS OCCUPANCY
BUSINESS OCCUPANCY
A-A STACK DIAGRAM
BUSINESS OCCUPANCY
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% SUBMISSION
NON-SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Engineering discipline:
Charlotte Engineers 5838 Monroe Rd # 100, Charlotte, NC 28212 704-531-3000
Esther Moallen Douglas Ehlers, P.E.
ODELL, A LaBella Company 795 Haywood Road Asheville, NC 28806 828-579-4426 Denice Regino / Michael Montgomery
NORTH
# 637-20-103
# 15
ASHEVILLE VA MEDICAL CENTER
PROGRAM MANAGER
Program manager:
Odell International 129 Fast Lane, Suite 200 Mooresville, NC 28117 704-401-2050 Richard Cantwell
KEYPLAN
NOT TO SCALE
B
IM
/4
-0
V A
A s h e v ill e -B u ild in g
R e n o v a ti o n s /4
-0
V
A A s h e v ill e B ld g n d F lo o r R e n o
A
R C
H
.r v t
/8
/2
:3
:5 P
M
GI002
CODE ANALYSIS RENOVATE BUILDING 15, 2ND FLOOR
Approver
02/09/2024 DR SLRevisions: Date: 2/9/2024
UP
FE
FE
FE
F
F
F
FIRE PROTECTION
EGRESS LEGEND
FEC
FE
EXIT EGRESS SYMBOLS
0.X"
XXX
X"
XXXXX
XXXX
XXX SF
XX OCC.
BUILDING EXIT
(MAX - 200' - 0")
199'
74'
99'
COMMON PATH OF
TRAVEL
(MAX - 75' - 0")
SUITE EXIT
(MAX - 100' - 0")
PARTITION PRIORITY
HE
LOWER PRIORITY WALL
HIGHER PRIORITY WALL
TWO HOUR FIRE RATED PARTITIONS
ONE HOUR FIRE RATED PARTITIONS
NON RATED PARTITIONS
PRIORITY 1
PRIORITY 2
PRIORITY 3
(HIGHEST)
(LOWEST)
HIGHER
PRIORITY
WALL
FIRE EXTINGUISHER
CABINET
BRACKET MOUNTED
FIRE EXTINGUISHER
CLEAR OPENING WIDTH
EXIT CAPACITY (7.3.1.2)
EGRESS LOAD (7.3.3.1)
OCCUPANCY TYPE
AREA
OCCUPANT LOAD
FACTOR (7.3.1.2)
OCCUPANT LOAD
DIRECTIONAL
ILLUMINATED EXIT
SIGN
BUILDING EXIT
DISCHARGE
SUITE EGRESS
INDICATOR
HORIZONTAL EXIT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
B.3
81' 93' 93'
61'
133'
0.2
47" 0.2
47" 0.2
47"
EXIT
REMOTENESS
192' - 8"
BUILDING
REMOTENESS
208 - '10"
6' - 3"
69'
27'
47'
5' - 5"
CORRIDOR
STAIR
S-1
OFFICE
OFFICE
TEAMS
ROOM
TR
STORAGE
ROOM
CORRIDOR
BREAKROOM
ELECTRICAL
228 TEAMS
ROOM
WOMENS
MENS
CORRIDOR
CONFERENCE
ROOM
CORRIDOR
OPEN
OFFICE
OPEN
OFFICE
OPEN
OFFICE
STAIR
S-3
CORRIDOR
PARTITION RATINGS
EXISTING PARTITION
EXISTING 1 HR - FIRE SEPARATION
EXISTING 2 HR - FIRE SEPARATION
NEW PARTITION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% SUBMISSION
NON-SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Engineering discipline:
Charlotte Engineers 5838 Monroe Rd # 100, Charlotte, NC 28212 704-531-3000
Esther Moallen Douglas Ehlers, P.E.
ODELL, A LaBella Company 795 Haywood Road Asheville, NC 28806 828-579-4426 Denice Regino / Michael Montgomery
NORTH
# 637-20-103
# 15
ASHEVILLE VA MEDICAL CENTER
PROGRAM MANAGER
Program manager:
Odell International 129 Fast Lane, Suite 200 Mooresville, NC 28117 704-401-2050 Richard Cantwell
KEYPLAN
NOT TO SCALE
B
IM
/4
-0
V A
A s h e v ill e -B u ild in g
R e n o v a ti o n s /4
-0
V
A A s h e v ill e B ld g n d F lo o r R e n o
A
R C
H
.r v t
/8
/2
:3
:5 P
M
GI003
LIFE SAFETY PLAN - SECOND
FLOOR
RENOVATE BUILDING 15, 2ND FLOOR
Approver
02/09/2024 DR SL
1/8" = 1'-0"
02 Second Floor_Life Safety Plan1
NOTE: SYSTEM FURNITURE SHOWN FOR
REFERENCE ONLY - FOR TRAVEL PATHS
Revisions: Date: 2/9/2024
FEFE
N E
C
NEC
1.
2.
3.
4.
5.
6.
7.
ENSURE RENOVATED AREA IS TO BE COMPLETELY SEALED OFF FROM SURROUNDING AREAS.
MAINTAIN MEANS OF EGRESS AT STAIR TOWERS DURING CONSTRUCTION. RESTRICT ACCESS TO FLOOR FROM WITHIN STAIRWELL DURING
CONSTRUCTION.
COORDINATE PHASING SCHEDULE WITH COR PRIOR TO STARTING CONSTRUCTION. VA HAS A MAXIMUM TIME LIMIT AREAS OF CONSTRUCTION CAN BE
CLOSED.
CEILINGS THAT ARE REMOVED/MODIFIED TO ALLOW CONSTRUCTION OF ICRA BARRIERS IS THE CONTRACTOR'S RESPONSIBILITY TO BE REINSTALLED TO
PRE-CONSTRUCTION CONDITIONS.
SECOND FLOOR CALL CENTER IS TO BE FULLY OPERATIONAL AND BE ABLE TO BE ACCESSED BY STAFF AT ALL TIMES. WORK THAT WOULD DISRUPT THE
SECOND FLOOR MUST BE COORDINATED WITH COR PRIOR TO CONSTRUCTION.
CONTRACTOR TO PROVDE DUST MATS AT ENTRANCE AND EXIT OF CONSTRUCTION AREAS.
ELEVATOR TO BE LOCKED OUT AT CONSTRUCTION AREA.
DUST CONTROL PLAN NOTES / DUST CONTROL PLAN HAZARD ASSESSMENT
PRIOR TO INITIATING WORK, CONTRACTOR WILL ASSESS THE SCOPE OF THE CONSTRUCTION ACTIVITIES AND DETERMINE THE POTENTIAL RISK GROUPS INVOLVED BASED ON THE LOCATION OF ACTIVITIES AND EXTENT AND DURATION OF THE WORK. LOW RISK GROUPS ARE CONSIDERED "OFFICE WORKERS", MEDIUM RISK GROUPS ARE CONSIDERED ALL INPATIENT AND OUTPATIENT AREAS NOT IN THE HIGH RISK GROUP. HIGH RISK GROUP DESIGNATION INCLUDES INPATIENT AREAS SUCH AS PEDIATRIC AND ADULT OPERATING/DELIVERY ROOMS, CATH LABS, MYELO SUPPRESSION UNITS, ICUS, DIALYSIS, NURSERIES AS WELL AS CLINIC AREAS (CLINICS ASSOCIATED WITH HEMATOLOGY, ONCOLOGY, PEDIATRIC INFECTION DISEASE, OR TRANSPLANT SERVICES) AND SERVICE AREAS (CENTRAL PROCESSING, STERILE PROCESSING, FOOD PREP & SERVICE AREA AND PHARMACIES. THE VAMC INFECTION CONTROL GROUP WILL CONFIRM AND APPROVE THE DESIGNATION PROVIDED IN THIS SUBMITTED DUST CONTROL PLAN. VAMC IS ALSO RESPONSIBLE FOR ANY AND ALL INFECTION CONTROL MEASURES DETERMINED AND ESTABLISHED BY VAMC POLICY, SUCH AS THE RELOCATION OF HIGH RISK PATIENTS, APPROVING ALTERNATE TRAFFIC PATHS FOR CONSTRUCTION WORKERS OR ESTABLISH ALTERNATE TRAFFIC PATTERNS FOR STAFF, PATIENTS AND VISITORS.
THE PLAN SHOULD BE REVISED ACCORDING TO SPECIFIC VAMC POLICIES OR CHANGING CONDITIONS AT THE SITE AS THEY MAY OCCUR.
FOR THE PURPOSE OF THIS RENOVATION, THE CONSTRUCTION WORK IS CONSIDERED ADJACENT TO MEDIUM RISK AND COMPRISES WORK WHICH COULD GENERATE MODERATE TO HIGH LEVELS OF DUST NOT WITHIN THE CONFINES OF A SUITE OR OFFICE AND INCLUDES EXTENSIVE CONSTRUCTION WORK (DEMOLITION) IN BUILDING 15 THROUGHOUT THE FIRST, SECOND FLOOR CEILING AND BASEMENT. THE DUST CONTROL PLAN SHALL BE DISTRIBUTED AND REVIEWED BY ALL CONTRACTORS PERFORMING WORK ON THIS CONSTRUCTION PROJECT.
EXTERNAL DEMOLITION AND CONSTRUCTION ACTIVITIES
DETERMINE IF THE IMPACTED AREAS OF THE FACILITY CAN OPERATE TEMPORARILY ON RECIRCULATED AIR; IF FEASIBLE SEAL OFF ADJACENT AIR INTAKES.
IF THIS IS NOT POSSIBLE OR PRACTICAL, CHECK THE LOW-EFFICIENCY FILTER BANKS FREQUENTLY AND REPLACE AS NEEDED TO AVOID BUILDUP OF PARTICULATE.
SEAL WINDOWS AND REDUCE WHEREVER POSSIBLE OTHER SOURCES OF OUTSIDE AIR INTRUSION (OPEN DOORS IN STAIRWELLS AND CORRIDORS) ESPECIALLY IN PROTECTIVE
ENVIRONMENT (PE) AREAS.
INTERNAL DEMOLITION AND CONSTRUCTION ACTIVITIES DUST AND DEBRIS CONTROL
BARRIER SYSTEMS: THE AREA SHOULD BE ISOLATED, AS THE PROJECT REQUIRES. SMALL, SHORT DURATION PROJECTS GENERATING MINIMAL DUST MAY USE FIRE-RATED PLASTIC SHEETING, BUT SHOULD BE SEALED AT FULL CEILING HEIGHT WITH AT LEAST 2-FOOT OVERLAPPING FLAPS FOR ACCESS TO ENTRY. PROJECTS THAT PRODUCE MODERATE TO HIGH LEVELS OF DUST REQUIRE RIGID, DUST-PROOF, AND FIRE-RATED BARRIER WALLS (E.G., DRYWALL) WITH CAULKED SEAMS FOR A TIGHT SEAL EXTENDING FLOOR TO CEILING. SEAL OFF AND BLOCK RETURN AIR VENTS IF RIGID BARRIERS ARE USED FOR CONTAINMENT. LARGE DUST PROJECTS NEED AN ENTRY VESTIBULE FOR CLOTHING CHANGES AND TOOL STORAGE AND TIGHT SEALS SHOULD BE MAINTAINED AT THE FULL PERIMETER OF WALLS AND WALL PENETRATIONS. AN INTERIM PLASTIC DUST BARRIER (MINIMUM 4-MIL) MAY BE REQUIRED TO PROTECT THE AREA WHILE THE RIGID IMPERVIOUS BARRIER IS BEING CONSTRUCTED. ANY DUST SHALL BE IMMEDIATELY CLEANED IF TRACKED OUTSIDE OF THE CONSTRUCTION BARRIER. UPON COMPLETION OF THE CONSTRUCTION PROJECT DUST BARRIERS SHALL BE REMOVED CAREFULLY TO MINIMIZE SPREADING OF DUST AND THE CONTRACTOR SHALL HAVE TEMPORARY DUST PROTECTION IN PLACE BEFORE REMOVAL OF A PERMANENT BARRIER. CONTRACTOR PERSONNEL SHALL MONITOR AND PERFORM BARRIER MAINTENANCE AND BE EDUCATED TO NOTICE SIMPLE CLUES SUCH AS ACCUMULATIONS OF VISIBLE DUST EVIDENCED BY FOOTPRINTS, OPENED DOORS/WINDOWS EVIDENCED BY PRESENCE OF INSECTS AND FLIES, WET CEILING TILE, ETC.
TRAFFIC CONTROL; DESIGNATED ENTRY AND EXIT PROCEDURES SHALL BE DEFINED. EGRESS PATHS SHOULD BE FREE OF DEBRIS; DESIGNATED ELEVATORS SHOULD BE USED DURING SCHEDULED TIMES; AND ONLY AUTHORIZED PERSONNEL SHOULD BE ALLOWED TO ENTER THE CONSTRUCTION ZONE. SIGNAGE SHOULD DIRECT PEDESTRIAN TRAFFIC AWAY FROM THE
CONSTRUCTION AREA AND MATERIALS.
DEMOLITION DEBRIS: DEBRIS SHOULD BE REMOVED IN CARTS WITH TIGHTLY FITTED COVERS, USING DESIGNATED TRAFFIC ROUTES. EFFORTS SHOULD BE MADE TO MINIMIZE USE OF ELEVATORS WITH AN EMPHASIS ON TRANSPORT DURING THE LOWEST PERIOD OF ACTIVITY. DEBRIS SHOULD BE REMOVED DAILY AND AT TIMES SPECIFIED BY THE VAMC. IF CHUTES ARE USED TO DIRECT DEBRIS OUTSIDE, HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTERED NEGATIVE AIR MACHINES SHOULD BE USED, AND THE CHUTE OPENING SHOULD BE SEALED WHEN NOT IN USE. FILTERS SHOULD BE BAGGED AND SEALED BEFORE BEING TRANSPORTED OUT OF THE CONSTRUCTION AREA. THE CONTRACTOR SHALL NOT HAUL DEBRIS THROUGH PATIENT-
CARE AREAS WITH PRIOR APPROVAL OF THE VAMC.
EXTERIOR WINDOWS: WINDOWS SHOULD BE SEALED TO MINIMIZE INFILTRATION FROM ANY ADJACENT EXCAVATION DEBRIS.
CEILINGS THAT ARE REMOVED/MODIFIED TO ALLOW CONSTRUCTION OF ICRA BARRIERS SHOULD BE REINSTALLED TO PRE-CONSTRUCTION CONDITIONS.
VENTILATION AND ENVIRONMENTAL CONTROLS
AIR SYSTEM FLOW: DETERMINE WHETHER THE CONSTRUCTION AREA USES FRESH/OUTSIDE OR RECIRCULATED AIR; FILTERS SHOULD BE ADDED OR RETURN VENTS COVERED AS NEEDED
WITH FILTER MATERIAL OR PLASTIC. AIR MUST FLOW FROM CLEAN TO DIRTY AREAS.
NEGATIVE AIR PRESSURE: THE AIR WITHIN THE CONSTRUCTION AREA MUST BE NEGATIVE WITH RESPECT TO SURROUNDING AREAS AND WITH NO DISRUPTION OF AIR SYSTEMS OF ADJACENT AREAS. USE OF THE NEGATIVE AIR PRESSURE SYSTEM WITHIN THE ENCLOSURE TO REMOVE DUST SHOULD PASS AIR THROUGH AN INDUSTRIAL GRADE, PORTABLE HEPA FILTER CAPABLE OF FILTRATION RATES OF 300-800 CUBIC FEET PER MINUTE (FT3//MIN), OR EXHAUST AIR DIRECTLY TO THE OUTSIDE IF APPROVED BY VAMC. IF EXHAUST MUST BE TIED INTO A RE- CIRCULATED AIR SYSTEM, A PRE-FILTER AND HEPA FILTER SHOULD BE USED BEFORE EXHAUST TO PREVENT CONTAMINATION OF THE DUCTS.
ADJACENT AREAS: THE STATUS OF SEALED PENETRATIONS AND INTACT CEILING SHOULD BE VERIFIED DAILY.
AIR EXCHANGE RATES AND PRESSURE RELATIONSHIPS: VAMC AND/OR CONTRACTOR WILL VERIFY AND MAINTAIN PROPER RATES IN CRITICAL AREAS NEAR CONSTRUCTION ACTIVITY AND ENSURE AIR IS NOT BEING RE-CIRCULATED WITHOUT FILTRATION FROM THE CONSTRUCTION AREA ELSEWHERE. VAMC WILL MAKE DETERMINATION ON PROVIDING FOR THE
ACCOUNTABILITY AND FREQUENCY OF TESTING AIR PRESSURE THROUGHOUT THE PROJECT.
MANOMETERS SHOULD BE LOCATED ON ICRA PARTITION DOOR AND ON THE NON-CONSTRUCTION SIDE OF THE PARTITION.
CONTAMINATION OF PATIENT ROOMS
WORKSITE CLOTHING: CONTRACTOR PERSONNEL CLOTHING SHOULD BE FREE OF LOOSE SOIL AND DEBRIS BEFORE LEAVING THE CONSTRUCTION AREA. IF PROTECTIVE APPAREL IS NOT WORK (E.G. COVERALLS, FOOTGEAR AND HEADGEAR) A HEPA-FILTERED VACUUM SHOULD BE USED TO REMOVE DUST FROM CLOTHING BEFORE LEAVING THE BARRICADE. IF PROTECTIVE APPAREL IS UTILIZED THE CONTRACTOR SHALL CONSTRUCT A SPACE OR ANTEROOM FOR CHANGING CLOTHING AND STORING EQUIPMENT (DESIGNATED AREA). ALL EQUIPMENT, TOOLS, TOOL CARTS, MATERIALS, ETC. TRANSPORTED THROUGH OCCUPIED AREAS SHALL BE MADE FREE FROM DUST AND MOISTURE BY VACUUMING AND WET WIPING BEFORE THEIR REMOVAL
FROM THE CONSTRUCTION ZONE OR WORK AREA.
CONTRACTOR CLEANING: THE CONSTRUCTION ZONE SHOULD BE MAINTAINED IN A CLEAN MANNER BY CONTRACTORS AND SWEPT OR HEPA-VACUUMED DAILY FOR MORE FREQUENTLY AS NEEDED TO MINIMIZE DUST. ADJACENT AREAS THAT MAY BE IMPACTED BY THE CONSTRUCTION SHOULD BE DAMP MOPPED DAILY OR MORE FREQUENTLY AS NEEDED. WALK-OFF MATS WITH TACKY OR ADHESIVE SURFACES SHOULD BE UTILIZED TO MINIMIZE TRACKING OF HEAVY DIRT AND DUST FROM CONSTRUCTION AREAS.
INFECTION CONTROL RISK ASSESSMENT FOR CONSTRUCTION
(TO BE COMPLETED BY CONTRACTOR AND SIGNED BY INFECTION CONTROL NURSE)
STEP #1: SELECT ACTIVITY TYPES BELOW:
CONSTRUCTION ACTIVITY TYPES:
TYPE B
SMALL SCALE, SHORT DURATION (LESS THAN 1 DAY) ACTIVITIES
WHICH CREATE MINIMAL DUST
INCLUDES, BUT NOT LIMITED TO:
INSTALLATION OF TELEPHONE AND COMPUTER CABLING
ACCESS TO CHASE SPACES
CUTTING OF WALLS OR CEILINGS WHERE DUST MIGRATION
CAN BE CONTROLLED
TYPE C
WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR
REQUIRES DEMOLITION OR REMOVAL OF ANY FIXED BUILDING
COMPONENTS OR ASSEMBLIES
INCLUDES, BUT NOT LIMITED TO:
SANDING OF WALLS FOR PAINTING OR WALL COVERING
REMOVAL OF FLOOR COVERING, CEILING TILES, AND
CASEWORK
NEW WALL CONSTRUCTION
MINOR DUCT WORK OR ELECTRICAL WORK ABOVE CEILINGS
MAJOR CABLING ACTIVITIES
ANY ACTIVITY WHICH CANNOT BE COMPLETED WITHIN A
SINGLE WORK SHIFT
TYPE A
INSPECTION AND NON-INVASIVE ACTIVITIES
INCLUDES, BUT NOT LIMITED TO:
REMOVAL OF CEILING TILES FOR VISUAL INSPECTION LIMITED
TO 1 TILE PER 50 SQUARE FEET
PAINTING (BUT NOT SANDING)
WALL COVERING
ELECTRICAL TRIM WORK
MINOR PLUMBING
ACTIVITIES WHICH DO NOT GENERATE DUST OR REQUIRE
CUTTING OF WALLS OR ACCESS TO CEILINGS OTHER THAN FOR
VISUAL INSPECTION
TYPE D
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS
INCLUDES, BUT NOT LIMITED TO:
ACTIVITIES THAT REQUIRE CONSECUTIVE WORK SHIFTS.
REQUIRES HEAVY DEMOLITION OR REMOVAL OF A
COMPLETE CABLING SYSTEM.
NEW CONSTRUCTION
IT IS LIKELY THE CONTRACTOR'S STAFF WILL BE PLACED AT RISK FOR
INFECTION WITH TUBERCULOSIS? YES / NO
IS IT LIKELY THERE WILL BE PHYSICAL DISRUPTION OF THE WATER
SYSTEM/LINES DURING ACTIVITY? YES / NO
STEP #2: SELECT RISK GROUP BELOW AND MARK BOTTOM OF COLUMN
A.) INFECTION CONTROL RISK GROUPS
GROUP 1 - LOW - OFFICE AREAS
GROUP 2 - MEDIUM - CARDIOLOGY, ECHOCARDIOLOGY, ENDOSCOPY,
NUCLEAR MEDICINE, PHYSICAL THERAPY, RADIOLOGY / MRI,
RESPIRATORY THERAPY
GROUP 3 - HIGH RISK - CCU, EMERGENCY ROOM, LABORATORIES,
OUTPATIENT SURGERY, PHARMACY, POST ANESTHESIA CARE UNIT,
SURGICAL UNITS
GROUP 4 - HIGHEST RISK - ANY AREA CARING FOR IMMUNOCOMPRIMISED
PATIENTS, CARDIAC CATH LABS, CENTRAL SUPPLY, INTENSIVE CARE
UNITS, MEDICAL UNITS, NEGATIVE AIRFLOW ROOMS, ONCOLOGY,
OPERATING ROOMS
STEP #3: DETERMINE CLASS OF PRECAUTIONS USING MATRIX BELOW:
CONSTRUCTION ACTIVITY / INFECTION CONTROL MATRIX TO DETERMINE CLASS
** ICN MUST BE CONSULTED WHEN THE ASSESSMENT INDICATES THAT CLASS II, III, IV
PRECAUTIONS ARE REQUIRED.
RISK LEVEL
GROUP 1
GROUP 2
GROUP 3
GROUP 4
TYPE 'A'
I
I
I
II
TYPE 'B'
II
II
II
III / IV
TYPE 'C'
II
III
III / IV
III / IV
TYPE 'D'
III / IV
IV
IV
IV
CONSTRUCTION TYPE:
D
RISK GROUP:
LOW
RISK ASSESSMENT:
III
PROJECTED UTILITY OUTAGES IMPACTING INFECTION CONTROL
ELECTRICAL
YES
POTABLE WATER
YES
HVAC
YES
MEDICAL VACUUM
NO
SEWER
YES
1.
2.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
STEP #4: COMPLETE THE INFECTION CONTROL CONSTRUCTION PERMIT:
CLASS I - DURING CONSTRUCTION PROJECT
EXECUTE WORK BY METHOD TO MINIMIZE RAISING DUST FROM
CONSTRUCTION OPERATIONS
IMMEDIATELY REPLACE A CEILING TILE DISPLACED FOR VISUAL
INSPECTION
CLASS II - DURING CONSTRUCTION PROJECT
PROVIDE ACTIVE MEANS TO PREVENT AIRBORNE DUST FROM
DISPERSING INTO ATMOSPHERE.
WATER MIST WORK SURFACES TO CONTROL DUST WHILE CUTTING
SEAL UNUSED DOORS WITH DUCT TAPE.
BLOCK OFF AND SEAL AIR VENTS.
PLACE DUST MAT AT ENTRANCE AND EXIT OF WORK AREA.
REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING
PERFORMED.
CLASS III - DURING CONSTRUCTION PROJECT
REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING
DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM.
COMPLETE ALL CRITICAL BARRIERS, I.E. SHEETROCK, PLYWOOD,
PLASTIC, TO SEAL AREA FROM NON-WORK AREA OR IMPLEMENT
CONTROL CUBE METHOD (CART WITH PLASTIC COVERING & SEALED
CONNECTION TO WORK SITE WITH HEPA VACUUM FOR VACUUMING
PRIOR TO EXIT ) BEFORE CONSTRUCTION BEGINS.
MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORKSITE UTILIZING HEPA-
EQUIPPED AIR FILTRATION UNITS.
CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORTATION IN TIGHTLY
COVERED CONTAINERS.
COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS
SOLID LID IS USED.
1.
2.
3.
4.
5.
6.
7.
CLASS IV - DURING CONSTRUCTION PROJECT
ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT
CONTAMINATION OF DUCT SYSTEM.
COMPLETE ALL CRITICAL BARRIERS, I.E., SHEETROCK, PLYWOOD, PLASTIC, TO
SEAL AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD
(CART WITH PLASTIC COVERING & SEALED CONNECTION TO WORK SITE WITH
HEPA VACUUM FOR VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS
MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORKSITE UTILIZE HEPA-EQUIPPED
AIR FILTRATION UNITS.
SEAL HOLES, PIPES, CONDUITS AND PUNCTURES APPROPRIATELY.
CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH THIS
ROOM SO THEY CAN BE VACUUMED USING HEPA VACUUM CLEANER BEFORE
LEAVING WORK SITE; OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT
ARE REMOVED EACH TIME THEY LEAVE THE WORK SITE.
ALL PERSONNEL ENTERING THE WORK SITE ARE REQUIRED TO WEAR SHOE
COVERS. SHOE COVERS MUST BE CHANGED EACH TIME THE WORKER EXITS THE
WORK AREA.
DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY SAFETY MANAGEMENT & INFECTION CONTROL & THOROUGHLY
CLEANED BY ENVIRONMENTAL MANAGEMENT.
1.
1.
2.
3.
4.
1.
2.
3.
4.
5.
CLASS I - UPON COMPLETION OF WORK
CLEAN WORK UPON COMPLETION OF TASK
CLASS II - UPON COMPLETION OF WORK
WIPE WORK SURFACES WITH DISINFECTANT.
CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED
CONTAINERS.
WET MOP AND/OR VACUUM BEFORE LEAVING WORK AREA
REMOVE ISOLATION OF HVAC SYSTEM IN AREA WHERE WORK IS BEING PERFORMED.
CLASS III - UPON COMPLETION OF WORK
DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY SAFETY MANAGEMENT & INFECTION CONTROL & THOROUGHLY
CLEANED BY ENVIRONMENTAL MANAGEMENT.
REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT & DEBRIS
ASSOCIATED WITH CONSTRUCTION.
VACUUM WORK AREA WITH HEPA-FILTER VACUUMS.
WET MOP WITH DISINFECTANT.
REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.
1.
2.
3.
4.
5.
6.
CLASS IV - UPON COMPLETION OF WORK
REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREAD OF DIRT & DEBRIS ASSOCIATED
WITH CONSTRUCTION.
CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.
COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
VACUUM WORK AREA WITH HEPA-FILTERED VACUUMS.
WET MOP WITH DISINFECTANT.
REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.
CONTRACTOR'S SIGNATURE AND DATE
INFECTION CONTROL NURSE'S SIGNATURE AND DATE
INTERIM LIFE SAFETY MEASURES (ILSM) REQUIREMENTS
1. PRIOR TO BEGINNING ACTUAL WORK ACTIVITIES, THE GENERAL CONTRACTOR IS TO WALK THROUGH
THE PLANNED WORK AREA(S) WITH REPRESENTATIVES OF THE VA SAFETY STAFF AND VA
CONTRACTING OFFICERS REPRESENTATIVES TO IDENTIFY AND PLAN FOR SAFETY ISSUES THAT MAY IMPACT HOSPITAL OPERATIONS AND LIFE SAFETY. THE ASSESSMENT SHOULD ADDRESS THE FOLLOWING
ITEMS:
A. WILL ANY EGRESS PATHWAYS OR EXITS BE ALTERED OR OBSTRUCTED?
B. WILL ACCESS TO EMERGENCY SERVICES BE RESTRICTED OR REROUTED, OR WILL ACCESS
FOR EMERGENCY RESPONDERS BE IMPAIRED OR RESTRICTED?
C. WILL ANY FIRE DETECTION OR ALARMS SYSTEMS BE IMPAIRED?
D. WILL ANY PART OF THE FIRE SUPPRESSION OR SPRINKLER SYSTEM BE IMPAIRED?
E. WILL ANY SMOKE/FIRE WALLS, DOORS, OR ASSEMBLIES BE COMPROMISED?
F. WILL THE FIRE SAFETY OF PERSONNEL IN ADJACENT ARES BE AFFECTED?
G. WILL IT BE NECESSARY TO INSTALL TEMPORARY CONSTRUCTION PARTITIONS?
H. WILL THE PROJECT RESULT IN THE ACCUMULATION OF DEBRIS AND/OR MATERIALS AND
INCREASE THE COMBUSTIBLE LOAD IN THE WORK AREA?
I. WILL THE PROJECT ACTIVITY INCLUDE SIGNIFICANT IGNITION SOURCES, I.E. CUTTING,
SOLDERING, OR OTHER ACTIVITIES UTILIZING AN OPEN FLAME?
J. WILL THE PROJECT ACTIVITY RESENT ANY OTHER SAFETY-RELATED HAZARDS?
2. THE VA WILL DOCUMENT THE ILSM ASSESSMENT AND PERFORM DAILY/WEEKLY OBSERVATIONS TO EVALUATE COMPLIANCE, DATA GATHERED DURING OBSERVATIONS WILL BE TRENDED, ISSUES IN NEED OF IMPROVEMENT WILL BE SHARED WITH THE GENERAL CONTRACTOR AND/OR MAINTENANCE PERSONNEL
TO ACHIEVE IMPROVEMENT.
3. UPON CLOSEOUT AND BEFORE THE PROJECT IS TURNED OVER TO THE END USERS, ALL LIFE SAFETY
DEFICIENCIES SHALL BE SHOWN TO HAVE CORRECTED. THE FOLLOWING
CLOSEOUT CHECKLIST SHALL FACILITATE THE PROCESS:
A. ALL EXISTS SHALL BE FREE AND UNOBSTRUCTED
B. ALL EXIT SIGNS ARE OPERATIONAL AND INSTALLED AS DESIGNED. ALL TEMPORARY SIGNS
SHALL BE REMOVED.
C. ALL ACCESS TO EMERGENCY SERVICES ARE RESTORED.
D. DOCUMENTED MAINTENANCE ACCEPTANCE TESTING FOR SMOKE/SPRINKLER SYSTEMS
SHALL BE PROVIDED.
E. ENSURE THE AREA IS EQUIPPED WITH THE APPROPRIATE NUMBER OF FIRE EXTINGUISHERS
PER CODE AND DESIGN.
F. ALL CONSTRUCTION MATERIALS AND EQUIPMENT SHALL BE REMOVED.
G. ALL EMERGENCY EVACUATION SIGNS ARE INSTALLED AND UPDATED.
H. ALL CEILING TILES AREA INSTALLED.
I. SPACES ARE CLEANED AND READY FOR OCCUPANCY.
J. ALL OTHER SAFETY RELATED HAZARDS OR CONDITIONS SHALL BE REMOVED.
UNDERSIDE OF EXISTING
DECK
FIRE RESISTANT SEALANT,
BOTH SIDES
UNDERSIDE OF
EXISTING DECK
UNDERSIDE OF EXISTING
DECK
EXISTING CEILING SYSTEM
FIRE RESISTANT
SEALANT, BOTH SIDES
EXISTING CEILING SYSTEM
PROVIDE HEADER TO
SPAN BETWEEN EXISTING
WALLS
FIRE RESISTANT SEALANT,
BOTH SIDES
PROVIDE BOX HEADER AT
DOOR
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
3 5/8" INSULATED WALL WITH
16 GAUGE METAL STUDS @
16" O.C. WALL TO EXTEND TO
UNDERSIDE OF DECK
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
3 5/8" 16 GAUGE METAL
STUDS @ 16" O.C. WALL TO
EXTEND TO UNDERSIDE OF
DECK
3 5/8" INSULATED WALL
WITH 16 GAUGE METAL
STUDS @ 16" O.C. (2)
LAYERS 5/8" GYPSUM
BOARD EACH SIDE.
WALL TO EXTEND TO
UNDERSIDE OF DECK
BASE - TO MATCH
EXISTING AREA
EXISTING FLOOR
BASE - TO MATCH
EXISTING AREA
EXISTING FLOOR
BASE - TO MATCH
EXISTING AREA
EXISTING FLOOR
5"
A
5"
1-HR RATED AND SMOKE RATED
U.L. DESIGN NO. U404 B
6"
SMOKE RATED C 2-HR RATED AND
SMOKE RATED
U.L. DESIGN NO. U404
5/8" FIRE RESISTANT
GYPSUM BOARD -
BOTH SIDES
EXISTING CEILING
SYSTEM
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L
D V
E R
IF
Y
W A
L L H
E
IG
H T
V A
R
IE
S F
IE
L
D V
E R
IF
Y
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L
D V
E R
IF
Y
/2
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L
D V
E R
IF
Y
W A
L L H
E
IG
H T
V A
R
IE
S F
IE
L
D V
E R
IF
Y
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
B.3
STAIR
S-1
STAIR
S-2ELEVATOR
ELEVATOR
STAIR
S-3
PHASING LEGEND
DESCRIPTIONSYMBOL
PHASE I - OPEN OFFICE 222,
RESTROOMS, SUPPORT
AREAS
PHASE II - OPEN OFFICE 116
& 117
PHASE III - CORRIDOR
ICRA WALL
EXISTING WALL TO BE USED
AS ICRA WALL
STICKY MAT
PARTITION RATINGS
EXISTING PARTITION
EXISTING 1 HR - FIRE SEPARATION
EXISTING 2 HR - FIRE SEPARATION
NEW PARTITION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% SUBMISSION
NON-SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Engineering discipline:
Charlotte Engineers 5838 Monroe Rd # 100, Charlotte, NC 28212 704-531-3000 Esther Moallen Douglas Ehlers, P.E.
ODELL, A LaBella Company 795 Haywood Road Asheville, NC 28806 828-579-4426 Denice Regino / Michael Montgomery
NORTH
# 637-20-103
# 15
ASHEVILLE VA MEDICAL CENTER
PROGRAM MANAGER
Program manager:
Odell International 129 Fast Lane, Suite 200 Mooresville, NC 28117 704-401-2050 Richard Cantwell
KEYPLAN
NOT TO SCALE
A u to d e s k D o c s /4
-0
V A
A s h e v ill e -B u ild in g
R e n o v a ti o n s /4
-0
V
A A s h e v ill e B ld g n d
F lo o r
R e n o
A
R C
H
.r v t
/1
/2
:2
:0
P M
GI004
SECOND FLOOR ICRA AND
PHASING PLAN
RENOVATE BUILDING 15, 2ND FLOOR
Approver
02/09/2024 DR SL
1/8" = 1'-0" 02 Second Floor_Phasing Plan1
12" = 1'-0" ICRA Wall Types5
ICRA KEYNOTE LEGEND
Key Value Keynote Text
01 BUILD TEMPORARY ICRA BARRIER WALL
TYPE 'B.' REMOVE WALL ONCE
CONSTRUCTION IS COMPLETE.
02 PROVIDE TEMPORARY CONSTRUCTION
DOOR IN ICRA WALL WITH STICKY MAT.
CONSTRUCTION DOOR TO BE 45 MINUTE
FIRE RATED.
03 EXISTING WALL TO BE USED AS ICRA WALL
DURING CONSTRUCTION. ALL WALL
PENETRATIONS TO BE FIRE STOPPED.
PATCH AND REPAIR ANY DAMAGE DURING
CONSTRUCTION. PAINT TO MATCH NEW
FINISHES.
04 STICKY MAT.
05 EXISTING WALL TO BE ICRA WALL DURING
CONSTRUCTION. ALL WALL PENETRATIONS
TO BE FIRE STOPPED. REMOVE AS SHOWN
UPON COMPLETION OF PHASE.
Revisions: Date:
Addendum 1 4/1/2025
'A'
4/1/2025
FEFE
N E
C
NEC
STAIR
S1
STAIR
S3
OFFICE
EXEC
OFFICE
OFFICE QM
OFFICE QM
OFFICE QM
223A
OFFICE QM
OFFICE
EXEC
OFFICE
STOR FMS
ELEC FMS
OFFICE QM
TOILET
EXEC OFF
STORAGE
STORAGE
STAIR
S2
OFFICE
MA-CPAC
OFFICE
G&EC
OFFICE QM
BREAKROOM
QA
OFFICE QM
218C
OFFICE QM
218B
CALL CTR
HAS
OFFICE
HAS
STOR FMS
OFFICE
HAS
OFFICE
MA-CPAC
212B OFFICE
MA-CPAC
212A
OFFICE
MA-CPAC
TOILET QM
STOR QM
218A
VEST
MA-CPAC
212C
STORAGE
HAS
TELE OI&T
STORAGE
MA-CPAC
200A
HAC FMS
OFFICE
HAS
TOILET
FMS
BREAKROOM
MA-CPAC
202A
TOILET
CONF
ROOM COS
OFFICE
MA-CPAC
204A
OFFICE
MA-CPAC
OFFICE
MA-CPAC
205A
OFFICE
MA-CPAC
OFFICE
EXEC
OFFICE
206A
OFFICE
EXEC
OFFICE
OFFICE
HAS
208A
Asbestos Abatement
AREAS WITH FLOOR TILE AND ASSOCIATED MASTIC UNDER CARPET
AREAS WITH FLOOR TILE AND ASSOCIATED MASTIC
NO ABATEMENT WORK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
B.3
THE SCOPE OF ABATEMENT WORK CONSISTS OF REMOVING VINYL FLOOR TILE, ASSOCIATED FLOORING MASTICS, CAULKING AROUND ROOM DOOR FRAMES, MASTIC LOCATED WITHIN THE WALKWAY, AND ASSUMED
FIRE DOORS. ALL WORK SHALL BE CONDUCTED IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL
REGULATIONS AND THE CONTRACT SPECIFICATIONS.
ALL WORK SHALL BE CONDUCTED DURING ADMINISTRATIVE HOURS (7:00 AM TO 5:00 PM) MONDAY - FRIDAY
EXCLUDING FEDERAL HOLIDAYS.
WORK SCHEDULES AND LIMITS OF ABATEMENT SHALL BE COORDINATED WITH THE VA COR AND CPIH FOR APPROVALS, UNLESS OTHERWISE INDICATED. THE ABATEMENT CONTRACTOR SHALL SUBMIT A DETAILED
WORK PLAN AND ABATEMENT SCHEDULE WITH THE REQUIRED SUBMITTALS AND CHANGES TO THE
PROCEDURES, CONTAINMENT LIMITS AND PHASING SHALL BE SUBMITTED TO THE VA COR FOR APPROVALS.
THE LOCATIONS AND QUANTITIES SHALL BE FIELD VERIFIED BY THE ABATEMENT CONTRACTOR. THE
CONTAINMENTS SHALL BE VERIFIED WITH THE VA COR AND VPIH/CIH.
ALL LOADOUT PROCEDURES SHALL BE COORDINATED WITH THE VA COR AND VPIH.
ALL POLYETHYLENE SHEETING USED FOR THE ABATEMENT PROJECT SHALL BE OF THE FIRE RETARDANT TYPE.
THE LOCATIONS OF ABATEMENT DECONTAMINATION UNITS AND WASTE DISPOSAL CONTAINERS SHALL BE
FIELD VERIFIED WITH THE VA COR. ALL LOADOUT PROCEDURES SHALL BE COORDINATED WITH THE VA COR.
ALL AIR MONITORING AND CLEARANCE SAMPLING SHALL BE CONDUCTED BY THE CPIH.
VA PERSONNEL SHALL BE RESPONSIBLE FOR REMOVING OR RELOCATING ALL DATA EQUIPMENT, COMPUTERS, SUPPLIES, FURNITURE, DESKS, WALL HANGINGS, ETC., FROM THE ABATEMENT AREAS.
STRICT COORDINATION BETWEEN THE VA OCCUPANTS, VA COR, CPIH, GENERAL CONTRACTOR AND
ABATEMENT CONTRACTOR SHALL BE REQUIRED.
GENERAL ABATEMENT NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
PARTITION RATINGS
EXISTING PARTITION
EXISTING 1 HR - FIRE SEPARATION
EXISTING 2 HR - FIRE SEPARATION
NEW PARTITION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% SUBMISSION
NON-SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Engineering discipline:
Charlotte Engineers 5838 Monroe Rd # 100, Charlotte, NC 28212 704-531-3000
Esther Moallen Douglas Ehlers, P.E.
ODELL, A LaBella Company 795 Haywood Road Asheville, NC 28806 828-579-4426 Denice Regino / Michael Montgomery
NORTH
# 637-20-103
# 15
ASHEVILLE VA MEDICAL CENTER
PROGRAM MANAGER
Program manager:
Odell International 129 Fast Lane, Suite 200 Mooresville, NC 28117 704-401-2050 Richard Cantwell
KEYPLAN
NOT TO SCALE
B
IM
/4
-0
V A
A s h e v ill e -B u ild in g
R e n o v a ti o n s /4
-0
V
A A s h e v ill e B ld g n d F lo o r R e n o
A
R C
H
.r v t
/8
/2
:3
:5 P
M
GI005
SECOND FLOOR ASBESTOS
ABATEMENT PLAN
RENOVATE BUILDING 15, 2ND FLOOR
Approver
02/09/2024 DR SEL
1/8" = 1'-0" 02 Second Floor_Asbestos Abatement Plan1
Revisions: Date:
MATERIAL SYMBOLS
CONCRETE MASONRY UNITS
(CMU)
CONCRETE
BRICK
CEMENT, SAND, GROUT, PLASTER,
OR GYPSUM WALL BOARD
EARTH
STONE, GRAVEL, OR POROUS
FILL
CARPET
PLYWOOD
WOOD (FINISHED)
WOOD (ROUGH)
RIGID INSULATION
BATT. OR LOOSE INSULATION
STEEL
WOOD (BLOCKING)
PARTICLE BOARD
ARCHITECTURAL DRAWINGS SYMBOLS
MATCH LINE
ELEVATION LINE
COLUMN LINE REFERENCES
DOOR TAGS
BUILDING SECTIONS
WALL SECTIONS
ARCHITECTURAL ABBREVIATIONS
A
X-XXX
X-XXX
X-XXX
DETAIL NO
SHEET NO
DETAIL NO
SHEET NO
A
B
FINISH FACE OF GYP
BD/STUD PARTITION
(U.O.N.)
NOMINAL FACE
OF MASONRY AND CONCRETE
WALL / PARTITIONS
(U.O.N.)
CENTER LINE
OF COLUMN
(U.O.N.)
TYPICAL PLAN DIMENSIONING
NOMINAL FACE OF
EXISTING PARTITION
(U.O.N.)
B
A: Area AB: Anchor Bolt ABV: Above ACC: Access ACOUST: Acoustical ACR: Acrylic ACST: Acoustic ACT: Acoustical Tile AD: Access Door ADH: Adhesive
ADJ: Adjust, Adjustable, Adjacent AFF: Above Finished Floor AGGR: Aggregate ALT: Alternate ALUM: Aluminum ANOD: Anodized AP: Access Panel APPROX: Approximate ATC: Acoustical Tile Ceiling
BDRM: Bedroom BETW: Between BF: Board Foot BIT: Bituminous BLDG: Building BLKG: Blocking BOT: Bottom
BPL: Bearing Plate BRG: Bearing BRK: Brick BRZ: Bronze BS: Both Sides BSMT: Basement BUR: Built-up Roof
C/C: Center to Center CAB: Cabinet CAR: Carpet CAV: Cavity CCW: Counter Clockwise CCTV: Closed Circuit TV CEM: Cement
CER: Ceramic CF: Cubic Feet CHAM: Chamfer CJ: Control Joint CK: Caulking CL: Centerline CLG: Ceiling CLKG: Caulking CLR: Clear CLR OPG: Clear Opening CMT: Ceramic Mosaic Tile CMU: Concrete Masonry Unit COL: Column CONC: Concrete CONSTR: Construction
CONT: Continuous CONTR: Contractor COP: Copper CPR: Copper CPT: Carpet CT: Ceramic Tile CW: Clockwise
EA: Each EB: Expansion Bolt EE: Each End EF: Each Face EHD Electric Hand Dryer EIFS: Exterior Insulation and Finish System EJ: Expansion Joint EL: Elevation, Elevator ELEC: Electrical ELEV: Elevator, Elevation
ENCL: Enclosure EPDM: Ethylene Propylene Diene Monomer EQ: Equal EQUIP: Equipment EW: Each Way EXG: Existing EXH: Exhaust EXIST: Existing EXP: Exposed
GA: Gauge, Gage GALV: Galvanized GC: General Contractor GL: Glass GL BLK: Glass Block
GRND: Ground GRTG: Grating GVL: Gravel GYP: Gypsum GYP BD: Gypsum Board
WINDOW TAG /
STOREFRONT TAG
DETAIL SECTIONS
X-XXX
DETAIL NO
SHEET NO
P. LAM: Plastic Laminate PAR: Parallel PBD: Particle Board PERIM: Perimeter PERP: Perpendicular PL: Plate PLBG: Plumbing PLYWD: Plywood PLUMB: Plumbing PR: Pair
PREFAB: Prefabricated PRES: Pressure PRESS: Pressure PRMLD: Premolded PRTN: Partition PSF: Pounds per square foot PSI: Pounds per square inch
PT: PAINT
PTD: Painted, Paper Towel Dispenser PTD/R: Combination Paper Towel Dispenser/Receptacle PTN: Partition
EXTERIOR ELEVATIONS
INTERIOR ELEVATIONS
DETAIL CALL OUTS
DETAIL NO0
X-XXX
DETAIL NO
SHEET NO
X-XXX2 4
SHEET NO
WALL TYPE
ROOM TAGROOM #
ROOM AREA
# PLAN/ELEVATION KEYNOTE
REVISION SYMBOL AND
CLOUD
C
D
E
F
G P
H
I
J
L
M
N
O
Q
R
S
T
DBL: Double DEG: Degree DEMO: Demolition DF: Drinking Fountain DIAG: Diagonal DIA: Diameter
DIAM: Diameter DIFF: Diffuser DN: Down DR: Door DWG: Drawing DWGS: Drawings DWR: Drawer
FB: Face Brick FD: Floor drain FDC: Fire Department Connection FDN: Foundation FDTN: Foundation FE: Fire Extinguisher FEC: Fire Extinguisher Cabinet FFE: Finished Floor Elevation
FF&E: Fixtures, Furnishings & Equipment FFL: Finished Floor Line FGL: Fiberglass FHC: Fire Hose Cabinet FIN: Finish, finished FIXT: Fixture
HDCP: Handicapped (better called "Accessible") HDW: Hardware HDWD: Hardwood HGT: Height
HM: Hollow Metal HORIZ: Horizontal HR: Hour HWD: Hardwood
ID: Inside Diameter IN: Inch INCL: Include INFO: Information
INSTL: Install INSUL: Insulation INT: Interior INTERM: Intermediate
JAN: Janitor JC: Janitor's Closet JT: Joint
FINISH KEYNOTE
LAB: Laboratory, Labor LAV: Lavatory LB: Pound (weight) LBL: Label LINO: Linoleum LNTL: Lintel
MAINT: Maintenance MAN; Manual MAR: Marble MARB: Marble MAS: Masonry MAT: Material MATL: Material
MAX: Maximum MECH: Mechanical MEMB: Membrane MFD: Manufactured MFG: Manufacturer, Manufacturing MFR: Manufacture, Manufacturer MI: Malleable Iron, Miles MIKE: Microphone MIN: Minimum MIR: Mirror MISC: Miscellaneous MK: Mark ML&P: Metal Lath & Plaster MLD: Molding
MLDG: Molding MM: Millimeter MMB: Membrane MO: Masonry Opening MOD: Module MONO: Monolithic MOV: Movable MP: Metal Acoustal Panel MPS: Medium Pressure Steam MR: Mop Receptor MRD: Metal Roof Deck MT: Mount, Mounted MTD: Mounted MTL: Material, Metal
MTR: Motor MUL: Mullion MULL: Mullion MV: Mercury Vapor MWP: Maximum Working Pressure MWK: Millwork
N: North, Nitrogen NAP: Napkin NAT: Natural NATL: Natural NB: "Nota Bene" Latin phrase for "Take Special Note" NC: Normally Closed, Noise Criteria NEC: National Electrical Code NEUT: Neutral NF: Near Face NFWH: Non-freeze Wall Hydrant
NI: Nickel NIC: Not In Contract NK: Neck NMT: Non-Metallic NO: Number, Normally Open NOM: Nominal NR: Noise Reduction NRC: Noise Reduction Coefficient NTS: Not To Scale
OB: Obscure OBS: Obscure OC: On Center OD: Outside Diameter OF: Outside Face OFF: Office
OH: Overhead OHD: Overhead Door OPNG: Opening OPP: Opposite OPP H: Opposite Hand
QUAL: Quality QT: Quarry Tile, Quart QTY: Quantity
RB: Rubber Base RCP: Reflected Ceiling Plan RD: Roof Drain, Round, Receptacle Distribution Panel REBAR: Reinforcing Bar REF: Refer, Reference, Refrigerator REFL: Reflected, REFR: Refrigerate, Refrigerator REINF: Reinforcement, or Reinforce
REQD: Required RESIL: Resilient RF: Roof RGH: Rough RGH OPNG: Rough Opening RO: Rough Opening RT: Rubber Tile
SALV: Salvage SCHED: Schedule SD Soap Dispenser SF: Square Foot SHR: Shower SHT: Sheet SND: Sanitary Napkin Disposal SPEC: Specification, Specifications SPECS: Specifications SQ: Square
SS: Stainless Steel STC: Sound Transmission Class STD: Standard STL: Steel STOR: Storage STRT: Straight STRUC: Structural STRUCT: Structural SUR: Surface SUSP: Suspended, Suspend
T&B: Top and Bottom T&G: Tongue & Groove TG Tempered Glass / Glazing TB: Towel Bar TD: Trench Drain TERR: Terrazzo THK: Thick, Thickness
THRU: Through TLT: Toilet TPD: Toilet paper Dispenser TPH: Toilet Paper Holder TPTN: Toilet Partition TYP: Typical TZ: Terrazzo
UNFIN: Unfinished UNO: Unless Noted Otherwise UON: Unless Otherwise Noted UP: Unpainted UR: Urinal
VAT: Vinyl Asbestos Tile VBC: Vinyl Base (Coved) VCT: Vinyl Composition Tile VERT: Vertical VEST: Vestibule
VIF: Verify In the Field VT: Vinyl Tile VTR: Vent Through Roof VWC: Vinyl Wall Covering
W/: With W/O: Without WAINS: Wainscot WC: Watercloset WD: Wood
U
V
W
A101
SIM
CS12.0b
W-
ROOM NAME
150 SF
XXX
F FL: Floor FLR: Floor FO: Finished Opening FOF: Face of Finish FOS: Face of Studs FP: Fireproof
FRT: Fire Retardant FT: Foot, Feet, FTG: Footing, Fitting FURN: Furnish, Furniture FURR: Furring
X-XXX
DETAIL NO
SHEET NO
Name Elevation
CONSTRUCTION SHALL CONFORM TO THE “INTERNATIONAL BUILDING CODE & NFPA 101 LIFE SAFETY CODE”, LATEST REVISION, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THE PROJECT IS BEING
CONSTRUCTED.
CONSTRUCTION SHALL COMPLY WITH FEDERAL CODES AND REGULATIONS.
ALL DRAWINGS ARE GRAPHIC REPRESENTATIONS OF APPROXIMATE LOCATIONS OF NEW MATERIALS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL CONDITIONS PRIOR TO COMMENCEMENT OF WORK.
CONTRACTORS ARE RESPONSIBLE FOR ALL MATERIALS, CONSTRUCTION METHODS AND CRAFTSMANSHIP.
CONTRACTORS ARE TO VERIFY ALL EXISTING CONDITIONS, REQUIREMENTS, NOTES, CODES AND DIMENSIONS, PRIOR TO THE START OF CONSTRUCTION AND SHALL NOTIFY THE ARCHITECT IF CONDITIONS VARY FROM THOSE
SHOWN ON THE DOCUMENTS.
CONTRACTORS ARE TO PROVIDE ADEQUATE SUPPORT OF EXISTING FOUNDATION WALLS, LOAD BEARING WALLS
AND PARTITIONS DURING DEMOLITION AND CONSTRUCTION.
THOROUGHLY COORDINATE WORK WITH OTHER TRADES AND DETERMINE THE EXACT ROUTE AND LOCATION OF
UTILITIES, MATERIALS AND EQUIPMENT BEFORE FABRICATION AND INSTALLATION.
WHEN EXISTING CONSTRUCTION IS REMOVED, DISTURBED, DAMAGED, REPLACED OR RENOVATED IN ANY WAY, CONTRACTORS SHALL PROVIDE PATCHING, PAINTING AND MATERIALS OF SAME TYPE AND QUALITY AS TO MATCH
ADJACENT EXISTING SURFACES, UNLESS OTHERWISE NOTED.
CONTRACTORS PROVIDE ALL BLOCKING, FURRING AND SHIMMING FOR INSTALLATION AND COMPLETION OF
WORK.
ALL NEW WORK SHALL BE PLUMB, LEVEL AND SQUARE. SCRIBE AND MAKE FIT ALL NEW TO EXISTING.
CONTRACTORS VERIFY ALL DIMENSIONS BEFORE ORDERING MATERIAL OR DOING WORK. NO EXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS
AND MEASUREMENTS INDICATED ON THE DRAWINGS.
ALL DETAILS ARE SUBJECT TO CHANGE DUE TO EXISTING FIELD CONDITIONS. CONTRACTOR MUST NOTIFY
ARCHITECT OF SAME.
THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR CHANGES TO THESE DRAWINGS AND COMPLETION OF
COMPLIANT WORK.
CONTRACTORS ARE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS ASSOCIATED WITH THE WORK
OF THEIR CONTRACT.
ITEMS NOTED AS 'BY OWNER” ARE TO BE FURNISHED AND INSTALLED BY THE OWNER OR THE OWNER'S VENDOR.
GENERAL CONSTRUCTION NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
UNLESS OTHERWISE NOTED, ALL MASONRY DIMENSIONING IS NOMINAL TO FACE OF MASONRY, ALL NON- MASONRY DIMENSIONING IS TO FACE OF PARTITIONS OR WALLS AND ALL CONCRETE DIMENSIONING IS FACE
TO FACE OF WALL.
ALL DIMENSIONS ARE TO THE OUTSIDE FINISH SURFACE OF WALLS OR TO COLUMN CENTERLINES.
ALL DIMENSIONS ARE FINISHES DIMENSIONS FROM FINISH FACE OF GYPSUM BOARD OR SCHEDULED WALL
FINISH UNLESS OTHERWISE NOTED.
PROVIDE CONCEALED BLOCKING IN ALL STUD PARTITIONS AND WALLS BEHIND SURFACE FOR SEMI-
RECESSED, FULLY RECESSED OR SURFACE MOUNTED ACCESSORIES AND MILLWORK.
DIMENSIONS NOTED AS “CLEAR” ARE TO FINISHED SURFACE AND ARE CRITICAL FOR ACCESSIBILITY
REQUIREMENTS OR BUILT-IN FURNISHINGS.
CONTRACTOR SHALL FIELD VERIFY FINISHED DIMENSIONS AND CLEARANCES IN SPACES INDICATED TO
RECEIVE BUILT-IN FURNISHINGS OR CASEWORK PRIOR TO FABRICATION.
ALL VERTICAL CONCRETE SURFACES WHICH WILL BE EXPOSED TO VIEW UPON COMPLETION OF WORK SHALL
RECEIVE A SMOOTH RUBBED FINISH.
ALL ENDS OF MASONRY WALLS THAT WILL BE EXPOSED TO VIEW UPON COMPLETION OF WORK SHALL BE
PLAIN END UNITS.
FINISHED DOOR OPENINGS SHALL BE NOMINAL 6” FROM FINISHED CORNER OF ROOM EXCEPT WHERE
DIMENSIONED OTHERWISE.
SEALANT SHALL BE PROVIDED AT THE INTERIOR AND EXTERIOR PERIMETER OF ALL WINDOWS, DOOR FRAMES, LOUVERS OR OTHER ITEMS INSERTED IN AN EXTERIOR WALL.
SUSPENDED GRID CEILINGS SHALL BE ARRANGED SO THAT A GRID IS SPACED EQUALLY FROM EACH MOST REMOTE WALL, IN EACH DIRECTION, WITH NO TILES LESS THAN 6” UNLESS OTHERWISE INDICATED.
WOOD USED FOR BLOCKING OR OTHER PURPOSES ON OR ABOVE THE ROOF DECK, WITHIN 2'-0” OF GRADE AND IN OTHER LOCATIONS OUTSIDE THE BUILDING ENVELOPE WHERE EXPOSED TO THE WEATHER SHALL BE
PRESSURE TREATED LUMBER OR PLYWOOD.
INSTALL ALL WORK AS INDICATED AND VERIFY EXACT LOCATION AND ELEVATIONS ON THE JOB.
DO NOT SCALE DRAWINGS. REFER TO DIMENSIONS AND SPECIFIED MATERIALS. CONTACT THE ARCHITECT IF
ADDITIONAL DIMENSIONS ARE REQUIRED.
COORDINATE ALL DOOR HARDWARE, TRIM AND FINISHES TO MEET INTENT AND COMPLIANCE.
INTERIOR WALL AND CEILING FINISH MINIMAL REQUIREMENTS (FINISH CLASSIFICATIONS IN ACCORDANCE
WITH ASTM E84) ARE INDICATED ON CODE REVIEW INFORMATION MATRIX.
GENERAL ARCHITECTURAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
PARTITION RATINGS
EXISTING PARTITION
EXISTING 1 HR - FIRE SEPARATION
EXISTING 2 HR - FIRE SEPARATION
NEW PARTITION
Project Number
Building Number