This is a limited asbestos bulk sampling and XRF paint testing report dated January 30, 2021, conducted by Affinity Energy & Environmental Engineers for Building #15's 3rd Floor East Renovation Area at the Charles George VAMC in Asheville, NC.
The report details results from two types of testing: 1) Four bulk samples of tan/gray sprayed-on fireproofing from the concrete ceiling deck were analyzed using PLM techniques, with no asbestos detected in any samples. 2) XRF paint testing was conducted on plaster walls and ceilings in Room 300, Room 301 closet, and the main corridor, with all ten test locations showing lead content well below the federal regulatory level of 1.0 mg/cm². The testing was conducted prior to renovation work, with samples analyzed by SAI laboratory in Greensboro, NC. The report includes complete laboratory analysis data sheets showing detailed sample compositions, with the fireproofing samples consisting of 98% mineral wool and 2% other materials.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Affinity Energy & Environmental Engineers, PA P.O. Box 2261
Asheville, NC 28802
Tele: 828-393-8182
January 30, 2021
Mr. Michael Bruno
Charles George VAMC
1100 Tunnel Road
Asheville, NC 28805-2087
RE: Limited Asbestos Bulk Sampling & XRF Paint Testing
Building #15 – 3rd Floor East Renovation Area
Charles George VAMC - Asheville, North Carolina
Affinity Project #13031IN
Mr. Bruno:
On January 28th, 2021, Affinity performed limited bulk sampling of suspect asbestos-containing sprayed-on fireproofing located on the concrete ceiling deck of the 3rd Floor East Renovation Area of Building #15 located on the VAMC campus in Asheville, NC. The sampling was conducted prior to disturbance of the fireproofing.
The samples were sent VIA Fed-ex to SAI in Greensboro, NC to be analyzed for asbestos content using PLM techniques. Following are the results of the sampling.
Sample # Location Material Asbestos Content
FP-01-01 Building #15 - 3rd Floor East Tan/Gray Sprayed-on Fireproofing None Detected
FP-01-02 Building #15 - 3rd Floor East Tan/Gray Sprayed-on Fireproofing None Detected
FP-01-03 Building #15 - 3rd Floor East Tan/Gray Sprayed-on Fireproofing None Detected
FP-01-04 Building #15 - 3rd Floor East Tan/Gray Sprayed-on Fireproofing None Detected
No asbestos was detected in the fireproofing samples. Please find laboratory analysis data sheets attached.
XRF paint testing was also conducted on the plaster ceiling in the Main Corridor of the 3rd Floor East
Renovation Area Following are the results of the XRF paint testing.
Index Time Color Substrate Component Location PbC mg/cm² Results
1 1/28/2021 14:19 WHITE PLASTER WALL 301 CLOSET 0.04 Negative
2 1/28/2021 14:20 WHITE PLASTER WALL 301 CLOSET 0.21 Negative
3 1/28/2021 14:20 WHITE PLASTER WALL 301 CLOSET 0.03 Negative
4 1/28/2021 14:21 WHITE PLASTER WALL 301 CLOSET 0.12 Negative
5 1/28/2021 14:22 WHITE PLASTER CEILING CORRIDOR AT 301 0.05 Negative
6 1/28/2021 14:22 WHITE PLASTER CEILING CORRIDOR AT 301 0.27 Negative
7 1/28/2021 14:22 WHITE PLASTER CEILING CORRIDOR AT 301 0.15 Negative
8 1/28/2021 14:23 WHITE PLASTER CEILING CORRIDOR AT 301 0.17 Negative
9 1/28/2021 14:25 WHITE PLASTER WALL ROOM 300 0 Negative
10 1/28/2021 14:25 WHITE PLASTER WALL ROOM 300 0 Negative
The plaster corridor ceiling does not contain lead in paint above the federal regulatory level of 1.0 mg/cm2.
Thank you for the opportunity to be of service. If you have any questions or require additional information, please do not hesitate to call.
Sincerely, Affinity Energy & Environmental Engineers, PA
Mike G. Cook, CIEC
NC Asbestos Inspector #12016
Attachment
Affinity Project #13031IN Limited Asbestos Bulk/XRF Paint Sampling Report
January 30, 2021 Building #15 – 3rd Floor East Renovation Area Charles George VAMC
Asheville, NC
LABORATORY ANALYSIS
DATA SHEETS
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E, App.E
VAMC Building #15Project:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Mike CookAttn:Customer: Affinity Energy & Environmental Engineers PO Box 2261 Asheville, NC 28802
Analysis ID: 71958850_PLM
Date Reported: 1/29/2021
Date Received: 1/29/2021
Lab Order ID: 71958850
None Detected
FP-01-01
3rd Floor East Gray Fibrous Heterogeneous
Teased71958850PLM_1
Mineral Wool Other 98% 2%
None Detected
FP-01-02
3rd Floor East Gray Fibrous Heterogeneous
Teased71958850PLM_2
Mineral Wool Other 98% 2%
None Detected
FP-01-03
3rd Floor East Gray Fibrous Heterogeneous
Teased71958850PLM_3
Mineral Wool Other 98% 2%
None Detected
FP-01-04
3rd Floor East Gray Fibrous Heterogeneous
Teased71958850PLM_4
Mineral Wool Other 98% 2%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Jalen Moore (4)
P-F-002 r15 1/16/2021
•· Scientific Analytical Institute 4604· Dundas Dr. Greensboro; NC 27407
Phone: 336.292.3888 Fax: 336.292.3313 www.sailab.com lab@sailab.com
Company Co.ntact Information Company: Affinity Energy & Environmental Engineers, PA Contact: Mike Cook
Address: P.O. Box 2261 Phone 0: (828) 508-3812
Ashville. NC 28802 Fax0:
Email Iii: mcook@affen-v.com
.Billin2/Invoice Information Turn Around Times Company~ SAME 90 Min. • 48 Hours • - I - Contact: j Hours LJ IL. -ttours LJ
Address: 6 Hours •~ 96 Hours • 12 Hours ~ 120Hours D 24 Hours • l44+Hours 0
I PO Number:
. Project Name/Number: \feimc ~,~l~\., 1\= ls
Lab Use Only\\nV\(7~/) Lab Order [D: \,. v \:Jl) D\l _ Client Code: ______ _
PLM EPA 600/R-93/l 16 (PLM)
Positive stop • PLM Point Count 400 (PT4) 0 PLM Point Count 1000 (PTM) 0 PCM N!OSH 7400-A Rules (PCM) 0 B Rules (PCB) 0 TWA (PT A) 0
TEM AHERA (AHE) 0
u .:,1s1 L<:V<,J H \L-HJ LJ
TEM NIOSH 7402 (TN!) •
TEM Bulk Qualitative (TBL) • TEM Bulk Chatfield (TBS) • TEM Bulk Quantitative (TBQ). • TEM Wipe ASTM D6480-05 • TEM Microvac ASTM D5755-02 • TEM Water EPA 100.2 (TWI) • Other: •
. Satnple ID # Description/Location Volume/Area • Comments
:3rJ F
Total # of Samples_£
Dateffime Date/Time
Page -dm ~~.21L21
| Affinity Project #13031IN |
| LABORATORY ANALYSIS |
| DATA SHEETS |
File details come from the government source that posted it. Updated .