EX. 1
PPC
EX. 19
IGC
EX. 20
IGC
EX. 22
IGC
EX. 16
IGC
EX. 18
TG
EX. 24
IGC
EX. 5
PPC
EX. 23
PPC
EX. 25
PPC
EX. 7
IGC
EX. 2
PPC
EX. 27
PPC
EX. 28
PPC
EX. 26
PPC
EX. 8
IGC
EX. 12
PPC
EX. 11
IGC
EX. 14
IGC
EX. 4
TG
EX. 15
IGC
EX. 3
PPC
EX. 9
IGC
EX. 10
IGC
EX. 13
PPC
EX. 21
IGC
EX. 17
IGC
EX. POND
(1.2 ac.)
VF
D
SO
LA
NO
D
RI
VE
SOLANO DRIVE
FOLSOM LAKE WAY
POTAH CREEK WAY
SI
ER
RA
N
EV
AD
A
DR
IV
E
SIERRA NEVADA DRIVE
DE
LT
A W
AY
CENTRAL
VALLEY
W
AY
MIDWAY ROADMIDWAY ROAD MIDWAY ROAD
T
COLUMBARIUM
IGC
IGC
IGC
IGC
PPC
PPC
PPC
PPC
PPC
IGC
IGC
IGC
IGC
PPC
PPC
IGC
IGC
COMMITTAL SHELTER RD.
SUTTER BUTTE DRIVE
SOLANO DR.
SOLANO DR.
ROAD A
SOLANO DR.
SUTTER BUTTE DR.
LAKE BERRYESSA DR.
LA
KE
BE
RR
YE
SS
A D
R.
SIERRA NEVADA DR.
JE
PS
ON
PR
AIR
IE
DR
PUTAH
CREEK
W
AY
PUTAH CREEK
WAY
ROUNDABOUT
ROAD R1
ROUNDABOUT
ROAD R2
ROUNDABOUT
ROAD R3
SIERRA NEVADA DR.
SERVICE RD.
STORM
STRUCTURE
SCHEDULE
NAME
CB-106A
CB-110A
CB-110B
CB-113A
CB-113B
CB-115A
CB-115B
CB-116A
CB-116B
CB-119
CB-122A
CB-122B
CB-205A
CB-207A
CB-207B
CB-208A
CB-208B
CB-209A
CB-209B
CB-302
CB-402
CB-502A
CB-506A
CB-507A
CB-507B
CB-509A
CB-509B
CB-513A
CB-513B
CB-515A
CB-516A
CB-516B
CB-519A
CB-519B
CB-603
CB-703
CB-902A
CB-903A
CB-907A
CB-908A
CB-908B
CB-909A
CB-909B
CB-1000A
CB-1000B
CB-1101
CB-1200
CB-1305A
CB-1305B
CB-1306A
SIZE
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
27"
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'X3'
2'X3'
2'X3'
2'X3'
2'x3'
2'x3'
2'x3'
2'x3'
2'X3'
2'X3'
2'X3'
2'X3'
2'X3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
27"
2'x3'
27"
CASTING
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-2533
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-2533
R-3067C
R-2533
STORM
STRUCTURE
SCHEDULE
NAME
CB-1306B
CB-1401A
CB-1404A
CB-1407A
CB-1409
CB-1410A
CB-1410B
CB -1700
CBMH-101
CBMH-102
CBMH-105
CBMH-201
CBMH-202A
CBMH-202B
CBMH-301
CBMH-401
CBMH-501
CBMH-505
CBMH-514
CBMH-602
CBMH-702
CBMH-801
CBMH-802
CBMH-901
CBMH-904
CBMH-906
CBMH-1100
CBMH-1301
CBMH-1302
CBMH-1303
CBMH-1304
CBMH-1305
CBMH-1306
CBMH-1401
CBMH-1407
CBMH-1408
EX.CB-1701
EX.STMH-1000
EX.STMH-1702
STMH-103
STMH-104
STMH-106
STMH-107
STMH-108
STMH-109
STMH-110
STMH-111
STMH-112
STMH-113
STMH-114
SIZE
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
2'x3'
48"
48"
2'x4'
48"
2'x3'
27"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
2'x3'
2'x3'
48"
48"
48"
2'x3'
60"
48"
48"
48"
48"
48"
60"
48"
60"
48"
48"
60"
48"
48"
48"
60"
48"
CASTING
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3573-2Q
R-3067C
R-3067C
R-2533
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-2533
R-2533
R-3067C
R-3067C
R-3067C
R-3067C
R-3067C
R-2533
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
STORM
STRUCTURE
SCHEDULE
NAME
STMH-115
STMH-116
STMH-117
STMH-118
STMH-120
STMH-121
STMH-122
STMH-202
STMH-203
STMH-204
STMH-205
STMH-206
STMH-207
STMH-208
STMH-209
STMH-502
STMH-503
STMH-504
STMH-506
STMH-507
STMH-508
STMH-509
STMH-510
STMH-511
STMH-512
STMH-513
STMH-515
STMH-516
STMH-517
STMH-518
STMH-519
STMH-601
STMH-701
STMH-902
STMH-903
STMH-905
STMH-907
STMH-908
STMH-909
STMH-1402
STMH-1403
STMH-1404
STMH-1405
STMH-1406
STMH-1410
SIZE
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
60"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
CASTING
R-1642
R-1642
R-2533
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
R-1642
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h t h i n c o e f o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e r s o t o n e i n o t o n e a d e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018 CS101
N 0 120' 240'
SCALE:1
STORM DRAIN PLAN - OVERALL
1" = 120' (30" x 42" PAPER SIZE)
LEGEND
CS101
STORM DRAIN PLAN - OVERALL
1. ALL STORM DRAIN PIPE TO BE 12" DIA. MIN. HDPE
UNLESS NOTED OTHERWISE
2. CRYPT FIELD UNDERDRAIN TO BE 6" PERFORATED
HDPE
3. LOW POINT OF CRYPT UNDERDRAIN SYSTEM TO BE
COLLECTED AT SUMP AND PUMPED TO STORM DRAIN
NETWORK IN STREET. SEE SHEETS CS112 TO CS115.
4. STRUCTURE SCHEDULE IS CATEGORIZED BY
STRUCTURE TYPE.
GENERAL NOTES
NEW STORM DRAIN
6" PERFORATED UNDERDRAIN
y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E P
LA
N
O V
E R
A
LL
.d w g
/2
5/
2:
P M
CAD IJW
CONSTRUCTION NOTES
1. STORM DRAIN MANHOLE FRAME & COVER SHALL
ADHERE TO THE CITY OF DIXON ENGINEERING
STANDARD DETAIL 400.
2. STORM DRAIN INLET FRAME AND GRATE SHALL BE
NEENAH FOUNDRY R-3501-TB, R-3501-TR, R-3501-TL
CONFORMING TO ROLL CURB OR APPROVED EQUAL.
NEW STORM
WATER PUMP NO. 1
(SEE SHEETS
CS109-CS111)
NEW STORM
WATER PUMP NO. 2
(SEE SHEETS
CS109-CS111)
POND 1
HWL = 64.50
POND 2
HWL = 64.50
EXISTING
POND
EXISTING POND
STORM
NETWORK 100
STORM
NETWORK 200
STORM
NETWORK 300
STORM
NETWORK 400
STORM
NETWORK 500
STORM
NETWORK 600
STORM
NETWORK 700
STORM
NETWORK 800
STORM
NETWORK 900
STORM
NETWORK 1000
STORM
NETWORK 1500
STORM
NETWORK 1400
STORM
NETWORK 1300
STORM
NETWORK 1200
STORM
NETWORK 1100
NEW STORM MANHOLE
NEW STORM CATCHBASIN
NEW FLARED END SECTION
WITH RIPRAP
NEW UNDERDRAIN CLEANOUT
STORM
NETWORK PLAN SHEETS PROFILE
SHEETS
100 CS102 CS301
200 CS102 CS301
300 CS103 CS302
400 CS103 CS302
500 CS104 CS302
600 CS105 CS303
700 CS105 CS303
800 CS104 CS303
900 CS106 CS303
1000 CS105 CS303
1100 CS107 CS303
1200 CS107 CS303
1300 CS108 CS303
1400 CS106 CS304
1500 CS108 CS304
1600 CS104 N/A
1700 CS107 N/A
UNDERDRAIN CS112 - CS115 N/A
EXISTING STORM DRAIN
STORM NETWORK BOUNDARY
PROVIDE LIGHT
AND HORN FOR
FAILURE
262129
STORM
NETWORK 1600
STORM
NETWORK 1700
IGC
IGC
IGC
IGC
COLUMBARIUM
3+00
4+00
5+00
6+00
7+00
8+00
9+00
10+00
11+00
11+78
1+
2+
3+
-0 +0
1+00
2+00
3+00
4+00
5+00
6+
7+
8+
8+
0+
1+
2+
3+
0+00
1+
2+00 3+00
4+
LA
KE
0+
1+00
2+003+00
SOLANO DR.
CREEK
WAY
CREEK
W
AY
SOLANO DR.
BE
RR
YE
SS
A
JE
PS
ON
PR
AIR
IE
DR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
STORM NETWORKS
100-200 PLAN
CS102y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E E
N
LA
R G
E M
E N
TS
.d w g
/2 5/
2:
P
M
CS102
LEGEND
N
0 30' 60'
SCALE:1
STORM NETWORKS 100-200 PLAN
1" = 30' (30"x42" PAPER)
NOTES - GENERAL
1. SEE SHEETS CS501 - CS506 FOR STORM
SEWER INSTALLATION DETAILS.
2. SEE STRUCTURE SCHEDULE ON SHEET
CS101 FOR INLET CASTING.
3. SEE SHEETS CS112 - CS115 FOR
UNDERDRAIN INSTALLATION DETAILS.
4. SEE SHEET CS301 FOR STORM NETWORK
100 AND 200 PROFILES.
CLEAN OUT
CRYPT LIMITS
FINISH GRADE68
NOTES - CONSTRUCTION
1. INSTALL STORM SEWER PIPING USING
DESIGN INVERT ELEVATIONS AS SHOWN.
PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE
UNLESS SHOWN OTHERWISE.
2. COORDINATES TO FES ARE AT THE
MIDDLE END OF THE FLAIRED END
STRUCTURE, RIP RAP SHADING IS
GRAPHICAL IN NATURE ONLY.
3. PUMP STATION COORDINATES ARE TO
THE CENTER OF VALVE MANHOLE WITH
BEARING OF OUTLET PIPE.
4. ALARM PANEL COORDINATES ARE TO THE
CENTER OF THE CONCRETE PAD. SEE
E-504 FOR ALARM PANEL DETAILS.
5. ALL FES OUTLET STRUCTURES ARE TO BE
ARMORED WITH RIP-RAP PER DETAIL
4/CS501.
6. COORDINATES/STA-OFFSET TO CATCH
BASINS ARE TO THE CENTER OF THE
STRUCTURE.
EXISTING GRADE68
NEW STORM SEWER
NEW STORM DRAIN STRUCTURE
NEW WATERMAIN
NEW ROAD CENTERLINE
HIGH WATER LINE (HWL)
CAD IJW
PERFORATED UNDERDRAIN
PIPE BEHIND CURB
PERFORATED UNDERDRAIN PIPE
262130
PPC
6+
7+
8+
9+00
10+00
11+00
12+00
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
STORM NETWORKS
300-400 PLAN
CS103y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E E
N
LA
R G
E M
E N
TS
.d w g
/2 5/
2:
P
M
N
0 30' 60'
SCALE:1
STORM NETWORKS 300-400 PLAN
1" = 30' (30"x42" PAPER)
POND 1
HWL = 64.50
CS103
NOTES - GENERAL
1. SEE SHEETS CS112 - CS115 FOR STORM
SEWER INSTALLATION DETAILS.
2. SEE STRUCTURE SCHEDULE ON SHEET
CS101 FOR INLET CASTING.
3. SEE SHEETS CS112 - CS115 FOR
UNDERDRAIN INSTALLATION DETAILS.
4. SEE SHEET CS302 FOR STORM NETWORK
300 AND 400 PROFILES.
NOTES - CONSTRUCTION
1. INSTALL STORM SEWER PIPING USING
DESIGN INVERT ELEVATIONS AS SHOWN.
PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE
UNLESS SHOWN OTHERWISE.
2. COORDINATES TO FES ARE AT THE
MIDDLE END OF THE FLARED END
STRUCTURE, RIP RAP SHADING IS
GRAPHICAL IN NATURE ONLY.
3. PUMP STATION COORDINATES ARE TO
THE CENTER OF VALVE MANHOLE WITH
BEARING OF OUTLET PIPE.
4. ALARM PANEL COORDINATES ARE TO THE
CENTER OF THE CONCRETE PAD. SEE
E-504 FOR ALARM PANEL DETAILS.
5. ALL FES OUTLET STRUCTURES ARE TO BE
ARMORED WITH RIP-RAP PER DETAIL
4/CS501.
6. COORDINATES/STA-OFFSET TO CATCH
BASINS ARE TO THE CENTER OF THE
STRUCTURE.
CAD IJW
LEGEND
CLEAN OUT
CRYPT LIMITS
FINISH GRADE68
EXISTING GRADE68
NEW STORM SEWER
NEW STORM DRAIN STRUCTURE
NEW WATERMAIN
NEW ROAD CENTERLINE
HIGH WATER LINE (HWL)
PERFORATED UNDERDRAIN
PIPE BEHIND CURB
PERFORATED UNDERDRAIN PIPE
PUMP STATION #1
SEE SHEETS CS109 - CS111
N.1912396.40 E.6595844.66
BEARING: S4°34'59"E
262131
IGC
IGC
IGC
33A
PPC
33B
9+0010+00
11+00
12+00
13+00
14+00
15+00
16+00
17+00 18+00
18+45
0+
1+00
2+00
3+00
4+00
5+00
6+
7+
7+
+7
+0
+0
+0
0+00
1+
2+00 3+00
4+
4+90
ROUNDABOUT
ROAD R2
ROAD A
SOLANO DR.
SOLANO DR.
LA
KE
BE
RR
YE
SS
A
DR
COORDINATE FINAL EAST/WEST
LOCATION OF PIPE OUTLET WITH VA
RE AND FARMER FOR BEST
PLACEMENT WITH RESPECT TO FIELD
DRAINAGE FOR AGRICULTURAL LAND
TO THE WEST. NOTIFY EOR OF FINAL
LOCATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
STORM NETWORKS
500, 800 & 1600 PLAN
CS104y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E E
N
LA
R G
E M
E N
TS
.d w g
/2 5/
2:
P
M
N
0 30' 60'
SCALE:1
STORM NETWORKS 500, 800 & 1600 PLAN
1" = 30' (30"x42" PAPER)
CS104
NOTES - GENERAL
1. SEE SHEETS CS112 - CS115 FOR STORM
SEWER INSTALLATION DETAILS.
2. SEE STRUCTURE SCHEDULE ON SHEET
CS101 FOR INLET CASTING.
3. SEE SHEETS CS112 - CS115 FOR
UNDERDRAIN INSTALLATION DETAILS.
4. SEE SHEET CS302 FOR STORM NETWORK
500 PROFILE.
5. SEE SHEET CS303 FOR STORM NETWORK
800 PROFILE.
6. SEE SHEET CS304 FOR STORM NETWORK
1600 PROFILE.
NOTES - CONSTRUCTION
1. INSTALL STORM SEWER PIPING USING
DESIGN INVERT ELEVATIONS AS SHOWN.
PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE
UNLESS SHOWN OTHERWISE.
2. COORDINATES TO FES ARE AT THE
MIDDLE END OF THE FLAIRED END
STRUCTURE, RIP RAP SHADING IS
GRAPHICAL IN NATURE ONLY.
3. PUMP STATION COORDINATES ARE TO
THE CENTER OF VALVE MANHOLE WITH
BEARING OF OUTLET PIPE.
4. ALARM PANEL COORDINATES ARE TO THE
CENTER OF THE CONCRETE PAD. SEE
E-504 FOR ALARM PANEL DETAILS.
5. ALL FES OUTLET STRUCTURES ARE TO BE
ARMORED WITH RIP-RAP PER DETAIL
4/CS501.
6. COORDINATES/STA-OFFSET TO CATCH
BASINS ARE TO THE CENTER OF THE
STRUCTURE.
POND 1
HWL = 64.50
POND 1
HWL = 64.50
SEE SHEETS CS109 - CS111 FOR
STORM DRAIN FORCEMAIN
DETAILS
CAD IJW
LEGEND
CLEAN OUT
CRYPT LIMITS
FINISH GRADE68
EXISTING GRADE68
NEW STORM SEWER
NEW STORM DRAIN STRUCTURE
NEW WATERMAIN
NEW ROAD CENTERLINE
HIGH WATER LINE (HWL)
PERFORATED UNDERDRAIN
PIPE BEHIND CURB
PERFORATED UNDERDRAIN PIPE
PUMP STATION #2
SEE SHEETS CS109 - CS111
N.1911242.79 E.6595992.73
BEARING: N90°00'00"E
36" TIDEFLEX CHECKMATE
BACKFLOW PREVENTER
SEE SHEET CS505
18" TIDEFLEX CHECKMATE
BACKFLOW PREVENTER
SEE SHEET CS505
262132
FIELD VERIFY HEADWALL LOCATION WITH CREEK
BANK SLOPE AND SOLANO COUNTY WATER
AGENCY'S (SCWA) ACCESS ROADWAY/EASEMENT.
MAINTAIN SCWA ACCESS ROAD ROUTE. ADJUST
HEADWALL LOCATION AS NECESSARY. NOTIFY
EOR OF DISCREPANCIES.
HEADWALL/WINGWALL
STRUCTURE PER 2/CS506 HEADWALL/WINGWALL
STRUCTURE PER 2/CS506
VF
D
T
EX. 7
IGC
EX. 27
PPC
EX. 28
PPC
PPC
EX. 8
IGC
EX. 9
IGC
EX. POND
(1.2 ac.)
IGC
IGC
PPC
19+00
20+00
21+00
+0
+0
+3
-0+00
1+00
BUTTE DR.
SUTTER
SOLANO DR.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
STORM NETWORKS
600, 700 & 1000 PLAN
CS105y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E E
N
LA
R G
E M
E N
TS
.d w g
/2 5/
2:
P
M
N
0 30' 60'
SCALE:1
STORM NETWORKS 600, 700 & 1000 PLAN
1" = 30' (30"x42" PAPER)
POND 1
HWL = 64.50
CS105
NOTES - GENERAL
1. SEE SHEETS CS112 - CS115 FOR STORM
SEWER INSTALLATION DETAILS.
2. SEE STRUCTURE SCHEDULE ON SHEET
CS101 FOR INLET CASTING.
3. SEE SHEETS CS112 - CS115 FOR
UNDERDRAIN INSTALLATION DETAILS.
4. SEE SHEET CS303 FOR STORM NETWORK
600, 700, AND 1000 PROFILES.
NOTES - CONSTRUCTION
1. INSTALL STORM SEWER PIPING USING
DESIGN INVERT ELEVATIONS AS SHOWN.
PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE
UNLESS SHOWN OTHERWISE.
2. COORDINATES TO FES ARE AT THE
MIDDLE END OF THE FLARED END
STRUCTURE, RIP RAP SHADING IS
GRAPHICAL IN NATURE ONLY.
3. PUMP STATION COORDINATES ARE TO
THE CENTER OF VALVE MANHOLE WITH
BEARING OF OUTLET PIPE.
4. ALARM PANEL COORDINATES ARE TO THE
CENTER OF THE CONCRETE PAD. SEE
E-504 FOR ALARM PANEL DETAILS.
5. ALL FES OUTLET STRUCTURES ARE TO BE
ARMORED WITH RIP-RAP PER DETAIL
4/CS501.
6. COORDINATES/STA-OFFSET TO CATCH
BASINS ARE TO THE CENTER OF THE
STRUCTURE.
CAD IJW
LEGEND
CLEAN OUT
CRYPT LIMITS
FINISH GRADE68
EXISTING GRADE68
NEW STORM SEWER
NEW STORM DRAIN STRUCTURE
NEW WATERMAIN
NEW ROAD CENTERLINE
HIGH WATER LINE (HWL)
PERFORATED UNDERDRAIN
PIPE BEHIND CURB
PERFORATED UNDERDRAIN PIPE
262133
EX. 5
IGC
PPC
9+00
10+00
11+00
12+00
13+00
14+00
15+00
16+00
17+00
18+00
0+
1+
2+00
3+00
4+00
5+00
6+
6+
2+
3+
4+
5+
6+00
7+00
8+00
0+00
1+
2+00 3+00
4+
4+90
ROUNDABOUT
R1
SOLANO DR.
SOLANO DR.
BUTTE DR.
SUTTER
COMMITTAL
SHELTER ROAD
SUTTER BUTTE
DR.
SUTTER BUTTE DR.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
STORM NETWORKS 900, 1400,
1500 & 1700 PLAN
CS106y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E E
N
LA
R G
E M
E N
TS
.d w g
/2 5/
2:
P
M
N
0 30' 60'
SCALE:1
STORM NETWORKS 900, 1400, 1500 & 1700 PLAN
1" = 30' (30"x42" PAPER)
CS106
4. SEE SHEET L6.18 FOR STORM NETWORK 1300 PROFILES.
NOTES - GENERAL
1. SEE SHEETS CS112 - CS115 FOR STORM
SEWER INSTALLATION DETAILS.
2. SEE STRUCTURE SCHEDULE ON SHEET
CS101 FOR INLET CASTING.
3. SEE SHEETS CS112 - CS115 FOR
UNDERDRAIN INSTALLATION DETAILS.
4. SEE SHEET CS303 FOR STORM NETWORK
900 PROFILES.
5. SEE SHEET CS304 FOR STORM NETWORK
1400 & 1500 PROFILES.
NOTES - CONSTRUCTION
1. INSTALL STORM SEWER PIPING USING
DESIGN INVERT ELEVATIONS AS SHOWN.
PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE
UNLESS SHOWN OTHERWISE.
2. COORDINATES TO FES ARE AT THE MIDDLE
END OF THE FLARED END STRUCTURE, RIP
RAP SHADING IS GRAPHICAL IN NATURE
ONLY.
3. PUMP STATION COORDINATES ARE TO THE
CENTER OF VALVE MANHOLE WITH
BEARING OF OUTLET PIPE.
4. ALL FES OUTLET STRUCTURES ARE TO BE
ARMORED WITH RIP-RAP PER DETAIL
4/CS501.
6. COORDINATES/STA-OFFSET TO CATCH
BASINS ARE TO THE CENTER OF THE
STRUCTURE.
POND 2
HWL = 64.50
POND 1
HWL = 64.50
4" HDPE
NON-PERFORATED PIPE
4" HDPE
NON-PERFORATED
PIPE
90° ELBOW FLUSH WITH THE FINISHED
GRADE CONCRETE TO CONNECT WITH
ROOF DOWNSPOUTS
90° ELBOW FLUSH WITH THE FINISHED
GRADE CONCRETE TO CONNECT WITH
ROOF DOWNSPOUTS
6" HDPE PERFORATED
DRAINTILE
6" HDPE PERFORATED
DRAINTILE
6"x6"x4" TEE
CLEANOUT
INV. = 67.70
6"x6"x4" TEE
CLEANOUT
INV. = 67.70
6" HDPE
NON-PERFORATED PIPE
6"x6" WYE
INV. = 66.90
6"x6" WYE
INV. = 65.84
COMMITTAL SHELTER
UNDERDRAIN CONNECTION TO
STORM NETWORK. SEE SHEET
CS304 FOR INVERT
CAD IJW
LEGEND
CLEAN OUT
CRYPT LIMITS
FINISH GRADE68
EXISTING GRADE68
NEW STORM SEWER
NEW STORM DRAIN STRUCTURE
NEW WATERMAIN
NEW ROAD CENTERLINE
HIGH WATER LINE (HWL)
PERFORATED UNDERDRAIN
PIPE BEHIND CURB
PERFORATED UNDERDRAIN PIPE
COMMITTAL SHELTER #3
18" TIDEFLEX CHECKMATE
BACKFLOW PREVENTER
SEE SHEET CS505
262134
HEADWALL/WINGWALL STRUCTURE PER 2/CS506.
FIELD VERIFY HEADWALL LOCATION WITH CREEK
BANK SLOPE AND SOLANO COUNTY WATER
AGENCY'S (SCWA) ACCESS ROADWAY/EASEMENT.
MAINTAIN SCWA ACCESS ROAD ROUTE. ADJUST
HEADWALL LOCATION AS NECESSARY. NOTIFY
EOR OF DISCREPANCIES.
10+00
11+00
12+00
13+00
14+00
15+00
16+00
17+00
+0
+0
+0
21+00
22+00
50+00
51+00
52+00
53+00
54+00
55+00
56+00
57+00
+0
+0
+0
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
STORM NETWORKS
1100 & 1200 PLAN
CS107y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E E
N
LA
R G
E M
E N
TS
.d w g
/2 5/
2:
P
M
N0 30' 60'
SCALE:1
STORM NETWORKS 1100 & 1200 PLAN
1" = 30' (30"x42" PAPER)
CS107
NOTES - GENERAL
1. SEE SHEETS CS112 - CS115 FOR STORM
SEWER INSTALLATION DETAILS.
2. SEE STRUCTURE SCHEDULE ON SHEET
CS101 FOR INLET CASTING.
3. SEE SHEETS CS112 - CS115 FOR
UNDERDRAIN INSTALLATION DETAILS.
NOTES - CONSTRUCTION
1. INSTALL STORM SEWER PIPING USING
DESIGN INVERT ELEVATIONS AS SHOWN.
PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE
UNLESS SHOWN OTHERWISE.
2. COORDINATES TO FES ARE AT THE MIDDLE
END OF THE FLAIRED END STRUCTURE,
RIP RAP SHADING IS GRAPHICAL IN
NATURE ONLY.
3. PUMP STATION COORDINATES ARE TO THE
CENTER OF VALVE MANHOLE WITH
BEARING OF OUTLET PIPE.
4. ALL FES OUTLET STRUCTURES ARE TO BE
ARMORED WITH RIP-RAP PER DETAIL
4/CS501.
CAD IJW
LEGEND
CLEAN OUT
CRYPT LIMITS
FINISH GRADE68
EXISTING GRADE68
NEW STORM SEWER
NEW STORM DRAIN STRUCTURE
NEW WATERMAIN
NEW ROAD CENTERLINE
HIGH WATER LINE (HWL)
PERFORATED UNDERDRAIN
PIPE BEHIND CURB
PERFORATED UNDERDRAIN PIPE
CONNECT TO EXISTING 12"
STORM DRAIN. EXTEND NEW
12" STORM DRAIN TO CB 1200
262135
CONNECT TO EXISTING STORM
STRUCTURE. EXTEND NEW 12"
STORM DRAIN TO CBMH 1100
0+00
1+00
2+
3+00
4+00
5+
6+
7+00
8+00
SUTT
ER BUTT
E DR.
SUTTER BUTTE DR.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
STORM NETWORK
1300 PLAN
CS108y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E E
N
LA
R G
E M
E N
TS
.d w g
/2 5/
2:
P
M
SCALE:1
STORM NETWORK 300 PLAN
1" = 30' (30"x42" PAPER)
CS108
NOTES - GENERAL
1. SEE SHEETS CS112 - CS115 FOR STORM
SEWER INSTALLATION DETAILS.
2. SEE STRUCTURE SCHEDULE ON SHEET
CS101 FOR INLET CASTING.
3. SEE SHEETS CS112 - CS115 FOR
UNDERDRAIN INSTALLATION DETAILS.
4. SEE SHEET CS303 FOR STORM NETWORK
1300 PROFILES.
NOTES - CONSTRUCTION
1. INSTALL STORM SEWER PIPING USING
DESIGN INVERT ELEVATIONS AS SHOWN.
PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE
UNLESS SHOWN OTHERWISE.
2. CONTRACTOR TO FIELD VERIFY THE
ELEVATION OF THE 6" IRRIGATION
SUPPLY LINE PRIOR TO CONSTRUCTION
OF STORM DRAIN FACILITIES AT OR NEAR
STA. 2+11. AS-BUILT DATA FOR THE 6"
IRRIGATION SUPPLY LINE SHOWS AN
APPROXIMATE ELEVATION OF THE
SOUTHEAST INTAKE, AT THE PUMP, OF
59.5. AS-BUILT DATA WAS UNAVAILABLE
FOR THE NORTHWEST OUTLET AT THE
IRRIGATION SUPPLY POND. NOTIFY RE
AND DESIGN A/E OF FIELD DETERMINED
ELEVATION OF 6" IRRIGATION SUPPLY
LINE IF IN CONFLICT WITH THE NEW
STORM DRAIN LINE BETWEEN MANHOLES
1303 AND 1304.
2. COORDINATES TO FES ARE AT THE
MIDDLE END OF THE FLAIRED END
STRUCTURE, RIP RAP SHADING IS
GRAPHICAL IN NATURE ONLY.
3. PUMP STATION COORDINATES ARE TO
THE CENTER OF VALVE MANHOLE WITH
BEARING OF OUTLET PIPE.
4. ALL FES OUTLET STRUCTURES ARE TO BE
ARMORED WITH RIP-RAP PER DETAIL
4/CS501.
6. COORDINATES/STA-OFFSET TO CATCH
BASINS ARE TO THE CENTER OF THE
STRUCTURE.
CAD IJW
LEGEND
CLEAN OUT
CRYPT LIMITS
FINISH GRADE68
EXISTING GRADE68
NEW STORM SEWER
NEW STORM DRAIN STRUCTURE
NEW WATERMAIN
NEW ROAD CENTERLINE
HIGH WATER LINE (HWL)
PERFORATED UNDERDRAIN
PIPE BEHIND CURB
PERFORATED UNDERDRAIN PIPE
N
0 30' 60'
RELOCATE
EXISTING
ELECTRICAL
HAND HOLE
262136
ROAD A
SOLANO
DRIVE
DRIVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F i l e
P a t h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
ENGINEERING
ENGINEERING ARCHITECTURE LAND SURVEYING
ENVIRONMENTAL SERVICES LANDSCAPE ARCHITECTURE
ANDERSON
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OFJune 27, 2018
CS109
PUMP STATION STORM DRAIN
FORCE MAIN PLAN 1 4803
THK CES
STORM DRAIN SITE PLAN 1
MATCH LINE SEE SHEET CS110
LEGEND
NOTES:
BERRYESSA
SUTTER BUTTE DRIVE
LAKE
DRIVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F i l e
P a t h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
ENGINEERING
ENGINEERING ARCHITECTURE LAND SURVEYING
ENVIRONMENTAL SERVICES LANDSCAPE ARCHITECTURE
ANDERSON
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OFJune 27, 2018
STORM DRAIN SITE PLAN 2
CS110
PUMP STATION STORM DRAIN
FORCE MAIN PLAN 2 4803
THK CES
MATCH LINE SEE SHEET CS109
LEGEND
MATCH LINE SEE SHEET CS111
SIERRA NEVADA DR.
LA
KE
BE
RR
YE
SS
A D
RIV
E
PUTAH
SIERRA NEVADA DR.
CREEK WAY
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F i l e
P a t h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
ENGINEERING
ENGINEERING ARCHITECTURE LAND SURVEYING
ENVIRONMENTAL SERVICES LANDSCAPE ARCHITECTURE
ANDERSON
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OFJune 27, 2018
STORM DRAIN SITE PLAN 3
CS111
PUMP STATION STORM DRAIN
FORCE MAIN PLAN 3 4803
THK CES
MATCH LINE SEE SHEET CS110
LEGEND
EX. 28
EX. POND
(1.2 ac.)
CO - 29-11
RIM: 68.99
INV: 61.19
UNDERDRAIN CLEANOUT
LOCATIONS
NAME
CO - 29-1
CO - 29-2
CO - 29-3
CO - 29-4
CO - 29-5
CO - 29-6
CO - 29-7
CO - 29-8
CO - 29-9
CO - 29-10
CO - 29-11
CO - 29-12
CO - 31-1
CO - 31-2
CO - 31-3
CO - 31-4
CO - 31-5
CO - 31-6
CO - 31-7
CO - 31-8
CO - 31-9
NORTHING
1911920.23
1911943.88
1912005.22
1912049.58
1912109.31
1912129.75
1912157.72
1912172.25
1912178.31
1912190.34
1912059.10
1911939.89
1911859.41
1911849.42
1911794.50
1911727.50
1911690.78
1911656.54
1911798.69
1911667.61
1911885.10
EASTING
6596494.01
6596498.07
6596459.89
6596436.44
6596420.93
6596408.20
6596404.88
6596391.14
6596355.77
6596285.68
6596367.57
6596379.37
6596529.14
6596587.39
6596659.13
6596712.57
6596706.28
6596700.40
6596537.09
6596618.09
6596379.41
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
UNDERDRAIN PLAN -
SECTIONS 29 & 31
CS112y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
C _D
R A
IN
A
G E
E N
LA
R
G E
M E
N
TS
.d w g
/2
5/
2:
P M
MBB JPN
N
0 30' 60'
LEGEND
UNDERDRAIN NOTES - GENERAL
1. SEE SHEET CS501 FOR UNDERDRAIN INSTALLATION
DETAILS.
CLEAN OUT
6" PERFORATED UNDERDRAIN PIPE
INVERT ELEVATIONXX.XX
CRYPT LIMITS
FINISH GRADE68
UNDERDRAIN NOTES - CONSTRUCTION
1. INSTALL UNDER DRAIN PIPING USING DESIGN INVERT
ELEVATIONS AS SHOWN. PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE UNLESS SHOWN
OTHERWISE.
2. SEE DETAIL 5/CS504 FOR PPC PUMP DETAILS.
SOLID HDPE FROM CO - 31-5
TO PPC PUMP 1
SOLID HDPE FROM CO - 29-9
TO PPC PUMP 1
262140
1 DRAIN ROCK AT PERIMETER UNDERDRAIN (TYPICAL)
NTS
CRYPT/GRAVESITE
(TYP.)
MIN. 6" DEPTH DRAIN ROCK
IN "STAIRSTEP" AREAS.
CONTINUE FROM CRYPT
FIELD TO 2' (MIN.) BEYOND
UNDERDRAIN COLLECTION
PIPE. TYPICAL ALL STAIRSTEP
AREAS OF ALL CRYPT FIELDS.
2.0 0'
PERIMETER
CRYPT/GRAVESITE
(TYP.)
SUTTER
BUTTE
DR.
SUTTER BUTTE DR.
ROUNDABOUT
ROAD R1
EX. POND
(1.2 ac.)
CO - 42-5
RIM: 69.00
INV: 61.20 (6")
CO - 40-6
RIM: 69.76
INV: 61.96 (6")
UNDERDRAIN CLEANOUT
LOCATIONS
NAME
CO - 34-1
CO - 34-2
CO - 34-3
CO - 34-4
CO - 34-5
CO - 34-6
CO - 34-7
CO - 34-8
CO - 34-9
CO - 40-1
CO - 40-2
CO - 40-3
CO - 40-4
CO - 40-5
CO - 40-6
CO - 40-7
CO - 40-8
CO - 40-9
NORTHING
1911791.54
1911733.67
1911676.14
1911554.54
1911539.43
1911518.64
1911780.42
1911662.99
1911648.20
1911849.18
1911938.33
1911978.67
1912043.82
1912109.79
1911839.44
1911827.94
1912022.14
1912098.93
EASTING
6595904.50
6595895.86
6595894.11
6595928.72
6596016.76
6596137.99
6595969.32
6595979.62
6596065.86
6595896.75
6595847.88
6595816.13
6595738.02
6595675.64
6595953.53
6596020.59
6595908.78
6595807.12
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
UNDERDRAIN PLAN -
SECTIONS 34 & 40
CS113y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
C _D
R A
IN
A
G E
E N
LA
R
G E
M E
N
TS
.d w g
/2
5/
2:
P M
MBB JPN
N
0 30' 60'
LEGEND
UNDERDRAIN NOTES - GENERAL
1. SEE SHEET CS501 FOR UNDERDRAIN INSTALLATION
DETAILS.
CLEAN OUT
6" PERFORATED UNDERDRAIN PIPE
INVERT ELEVATIONXX.XX
CRYPT LIMITS
FINISH GRADE68
UNDERDRAIN NOTES - CONSTRUCTION
1. INSTALL UNDER DRAIN PIPING USING DESIGN INVERT
ELEVATIONS AS SHOWN. PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE UNLESS SHOWN
OTHERWISE.
2. SEE DETAIL 5/CS504 FOR PPC PUMP DETAILS.
BEGIN 12 LF SOLID
WALL HDPE (NORTH
SIDE OF CLEANOUT)
SOLID HDPE FROM CO - 31-6
TO PPC PUMP 2
SOLID WALL HDPE
262141
LAKE
BERRYESSA DR.
SOLANO DR.
ROUNDABOUT
ROAD R2
P33
P34
P35P42
G
H
I
CO - 42-5
RIM: 69.00
INV: 61.20 (6")
UNDERDRAIN CLEANOUT
LOCATIONS
NAME
CO - 42-1
CO - 42-2
CO - 42-3
CO - 42-4
CO - 42-5
CO - 42-6
CO - 42-7
CO - 42-8
CO - 44-1
CO - 44-2
CO - 44-3
CO - 44-4
CO - 44-5
CO - 44-6
CO - 44-7
CO - 44-8
CO - 44-9
CO - 44-10
CO - 44-11
NORTHING
1912359.00
1912301.50
1912205.83
1912182.38
1912163.36
1912139.94
1912285.78
1912394.84
1912471.39
1912532.21
1912590.75
1912644.15
1912702.25
1912738.17
1912732.36
1912726.33
1912459.08
1912620.64
1912622.57
EASTING
6595621.62
6595619.89
6595629.66
6595640.04
6595750.90
6595887.43
6595720.40
6595767.81
6595640.90
6595651.33
6595673.20
6595712.68
6595752.62
6595789.15
6595823.03
6595858.14
6595712.70
6595791.14
6595779.91
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
UNDERDRAIN PLAN -
SECTIONS 42 & 44
CS114y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
C _D
R A
IN
A
G E
E N
LA
R
G E
M E
N
TS
.d w g
/2
5/
2:
P M
MBB JPN
N
0 30' 60'
LEGEND
UNDERDRAIN NOTES - GENERAL
1. SEE SHEET CS501 FOR UNDERDRAIN INSTALLATION
DETAILS.
CLEAN OUT
6" PERFORATED UNDERDRAIN PIPE
INVERT ELEVATIONXX.XX
CRYPT LIMITS
FINISH GRADE68
UNDERDRAIN NOTES - CONSTRUCTION
1. INSTALL UNDER DRAIN PIPING USING DESIGN INVERT
ELEVATIONS AS SHOWN. PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE UNLESS SHOWN
OTHERWISE.
2. SEE DETAIL 5/CS504 FOR PPC PUMP DETAILS.
BEGIN 14 LF SOLID
WALL HDPE
BEGIN 40 LF SOLID
WALL HDPE
262142
LA
KE
B
YR
REY
ES
SA
D
R.
CO - 45-8
RIM: 70.41
INV: 62.61
UNDERDRAIN CLEANOUT
LOCATIONS
NAME
CO - 45-1
CO - 45-2
CO - 45-3
CO - 45-4
CO - 45-5
CO - 45-6
CO - 45-7
CO - 45-8
CO - 45-9
NORTHING
1913123.66
1913185.25
1913223.18
1913270.49
1913106.67
1913072.20
1913048.19
1913191.39
1913251.76
EASTING
6595529.26
6595507.36
6595481.40
6595489.51
6595575.05
6595634.07
6595774.02
6595622.37
6595616.44
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
KEY MAP: N.T.S.
CREEK
CREEK
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
UNDERDRAIN PLAN -
SECTION 45
CS115y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
C _D
R A
IN
A
G E
E N
LA
R
G E
M E
N
TS
.d w g
/2
5/
2:
P M
MBB JPN
N
0 30' 60'
LEGEND
UNDERDRAIN NOTES - GENERAL
1. SEE SHEET CS501 FOR UNDERDRAIN INSTALLATION
DETAILS.
CLEAN OUT
6" PERFORATED UNDERDRAIN PIPE
INVERT ELEVATIONXX.XX
CRYPT LIMITS
FINISH GRADE68
UNDERDRAIN NOTES - CONSTRUCTION
1. INSTALL UNDER DRAIN PIPING USING DESIGN INVERT
ELEVATIONS AS SHOWN. PIPE GRADE BETWEEN INVERT
ELEVATIONS SHALL BE UNIFORM GRADE UNLESS SHOWN
OTHERWISE.
2. SEE DETAIL 5/CS504 FOR PPC PUMP DETAILS.
12 LF 6" SOLID WALL
HDPE
262143
SIERRA NEVADA DR.
C B
-1
A
IN
V
4.
(S
E
R
IM
7.
S
TM
H -1
IN
V
4.
(N
W
IN
V
3.
(N
E
IN
V
3.
(S
E
R
IM
7.
S
TM
H -1
IN
V
3.
(S
W
IN
V
3.
(S
E
R
IM
7.
S
TM
H -1
IN
V
3.
(N
W
IN
V
3.
(S
IN
V
3.
(N E
IN
V
3.
(S W
R
IM
6.
S
TM
H -1
IN
V
2.
(N
W
IN
V
2.
(S
E
IN
V
3.
(S
W
IN
V
2.
(N
E
R
IM
7.
S
TM
H -1
IN
V
2.
(N
W
IN
V
2.
(S
W
R
IM
7.
S
TM
H -1
IN
V
2.
(N
IN
V
2.
(S E
R
IM
7.
S
TM
H -1
IN
V
2.
(N
E
IN
V
2.
(S
W
IN
V
3.
(N
W
IN
V
3.
(S
E
R
IM
6.
S
TM
H -1
IN
V
2.
(N
W
IN
V
2.
(E
R
IM
8.
S
TM
H -1
IN
V
1.
(W
IN
V
1.
(E
R
IM
8.
S
TM
H -1
IN
V
1.
(W
IN
V
1.
(S
IN
V
3.
(N
R
IM
7.
C B
M H
-1
IN
V
1.
(N
IN
V
1.
(S E
R
IM
7.
S
TM
H
-1
IN
V
1.
(S
IN
V
1.
(N W
R
IM
8.
S
TM
H -1
IN
V
1.
(E
IN
V
1.
(N
R
IM
7.
17 LF 12" HDPE @ 1.30%
40 LF 12" HDPE @ 0.62%
117 LF 12" HDPE @ 0.48% 94 LF 12" HDPE @ 0.25% 56 LF 12" HDPE @ 0.25%
41 LF 12" HDPE @ 0.25%
132 LF 15" HDPE @ 0.25% 63 LF 24" HDPE @ 0.25% 71 LF 24" HDPE @ 0.25% 64 LF 24" HDPE @ 0.25%
17 LF 24" HDPE @ 0.29%
139 LF 24" HDPE @ 0.25%
11 LF 24" HDPE @ 0.27%
FINISHED GRADE AT ℄ OF SD PIPE
EXISTING GROUND AT ℄ OF SD PIPE
C B
M H
-1
IN
V
0.
(W
IN
V
0.
(S E
R
IM
6.
C B
M H
-1
IN
V
0.
(N
W
IN
V
0.
(E
R
IM
6.
FE
S
-1
IN
V
0.
(W
230 LF 24" HDPE @ 0.25%
23 LF 24" HDPE @ 0.26%
138 LF 24" HDPE @ 0.29%
FINISHED GRADE AT ℄ OF SD PIPE
EXISTING GROUND AT ℄ OF SD PIPE
S
TM
H -1
IN
V
3.
(N
IN
V
3.
(S E
R
IM
8.
S
TM
H -1
IN
V
3.
(N
W
IN
V
3.
(S
E
R
IM
8.
S
TM
H -1
IN
V
2.
(N
W
IN
V
2.
(S
E
IN
V
3.
(S
W
IN
V
2.
(N
E
R
IM
7.
72 LF 12" HDPE @ 0.39% 70 LF 12" HDPE @ 0.40% 65 LF 12" HDPE @ 0.40%
S
TM
H -1
IN
V
3.
(W
IN
V
3.
(S
IN
V
3.
(E
R
IM
7.
FINISHED GRADE AT ℄ OF SD PIPEEXISTING GROUND AT ℄ OF SD PIPE
S
TM
H -1
IN
V
3.
(S
W
IN
V
3.
(N
E
IN
V
3.
(N
W
IN
V
3.
(S
E
R
IM
7.
S
TM
H -1
IN
V
4.
(S
E
IN
V
4.
(N
E
R
IM
8.
S
TM
H -1
IN
V
3.
(N
W
IN
V
3.
(N
E
R
IM
6.
S
TM
H -1
IN
V
2.
(N
W
IN
V
2.
(S
E
IN
V
3.
(S
W
IN
V
2.
(N
E
R
IM
7.
223 LF 12" HDPE @ 0.27% 126 LF 15" HDPE @ 0.28%
45 LF 15" HDPE @ 0.29%FINISHED GRADE AT ℄ OF SD PIPE
EXISTING GROUND AT ℄ OF SD PIPE
49 LF 12" HDPE @ 0.20%
C B
-1
IN
V
4.
(S
W
R
IM
7.
S
TM
H -1
C
B -1
A
IN
V
3.
(S
R
IM
7.
6 LF 12" HDPE
@ 0.99%
C B
-1
A
IN
V
3.
(S
E
R
IM
6.
S
TM
H -1
IN
V
2.
(N
E
IN
V
2.
(S
W
IN
V
3.
(N
W
IN
V
3.
(S
E
R
IM
6.
C
B -1
B
IN
V
3.
(N
W
R
IM
6.
17 LF 12" HDPE
@ 0.47%
6 LF 12" HDPE @ 0.46%
C B
-1
A
IN
V
3.
(N
E
R
IM
6.
C B
-1
B
IN
V
3.
(S
W
R
IM
6.
S
TM
H -1
IN
V
3.
(N
W
IN
V
3.
(S
IN
V
3.
(N E
IN
V
3.
(S W
R
IM
6.
17 LF 12" HDPE
@ 0.41%
6 LF 12" HDPE @ 1.13%
C B
-1
B
IN
V
4.
(N
W
R
IM
7.
S
TM
H -1
10 LF 12" HDPE @ 2.31%
C B
-1
B
IN
V
3.
(W
R
IM
7.
C B
-1
A
IN
V
3.
(E
R
IM
7.
S
TM
H -1
IN
V
3.
(W
IN
V
3.
(S
IN
V
3.
(E
R
IM
7.
7 LF 12" HDPE @ 1.22%
17 LF 12" HDPE
@ 0.71% 55
C B
-1
B
IN
V
3.
(N
W
R
IM
7.
S
TM
H -1
IN
V
3.
(S
W
IN
V
3.
(N
E
IN
V
3.
(N
W
IN
V
3.
(S
E
R
IM
7.
C B
-1
A
IN
V
3.
(S
E
R
IM
7.
7 LF 12" HDPE @ 2.24%
17 LF 12" HDPE
@ 1.49%
S
TM
H -2
IN
V
3.
(S
W
IN
V
3.
(S
E
IN
V
3.
(N
E
R
IM
6.
S
TM
H -2
IN
V
2.
(N
W
IN
V
2.
(E
IN
V
2.
(S W
R
IM
7.
S
TM
H -2
IN
V
2.
(W
IN
V
2.
(E
IN
V
2.
(N
R
IM
7.
S
TM
H -2
IN
V
2.
(W
IN
V
2.
(E
R
IM
6.
S
TM
H -2
IN
V
2.
(W
IN
V
1.
(E
IN
V
2.
(S
R
IM
6.
S
TM
H -2
IN
V
1.
(W
IN
V
1.
(S
IN
V
1.
(N
R
IM
5.
C B
M H
-2
IN
V
1.
(N
IN
V
1.
(S
R
IM
5.
FE
S
-2
IN
V
1.
(N
132 LF 12" HDPE @ 0.25% 81 LF 12" HDPE @ 0.26% 67 LF 12" HDPE @ 0.25% 67 LF 15" HDPE @ 0.25% 112 LF 15" HDPE @ 0.25%
17 LF 15" HDPE @ 0.46%
61 LF 15" HDPE @ 0.51%
FINISHED GRADE AT ℄ OF SD PIPEEXISTING GROUND AT ℄ OF SD PIPE
S
TM
H -2
IN
V
1.
(W
IN
V
1.
(S
IN
V
1.
(N
R
IM
5.
C B
M H
-2
B
IN
V
2.
(S
R
IM
5.
C B
M H
-2
A
IN
V
1.
(N
IN
V
1.
(S
R
IM
5.
41 LF 12" HDPE @ 2.88%
6 LF 12" HDPE @ 0.49%
S
TM
H -2
IN
V
2.
(W
IN
V
1.
(E
IN
V
2.
(S
R
IM
6.
S
TM
H -2
IN
V
2.
(W
IN
V
2.
(N
IN
V
2.
(E
R
IM
5.
C B
-2
A
IN
V
2.
(E
R
IM
5.
47 LF 12" HDPE @ 0.49%
17 LF 12" HDPE @ 0.71%
FINISHED GRADE AT ℄ OF SD PIPE
EXISTING GROUND
AT ℄ OF SD PIPE
S
TM
H -2
C
B -2
B
IN
V
2.
(W
R
IM
5.
6 LF 12" HDPE @ 0.77%
S
TM
H -2
IN
V
2.
(W
IN
V
2.
(E
IN
V
2.
(N
R
IM
7.
7 LF 12" HDPE
@ 0.77%
C B
-2
A
IN
V
2.
(S
R
IM
7.
S
TM
H -2
C B
-2
B
IN
V
4.
(N
W
R
IM
7.
24 LF 12" HDPE @ 1.42%
S
TM
H -2
IN
V
2.
(N
W
IN
V
2.
(E
IN
V
2.
(S W
R
IM
7.
C B
-2
A
IN
V
4.
(S
E
R
IM
7.
S
TM
H -2
IN
V
3.
(S
E
IN
V
3.
(N
E
IN
V
3.
(N
W
R
IM
7.
21 LF 12" HDPE
@ 1.53%
24 LF 12" HDPE @ 3.32%
S
TM
H -2
IN
V
3.
(S
W
IN
V
3.
(S
E
IN
V
3.
(N
E
R
IM
6.
C B
-2
B
IN
V
3.
(N
E
R
IM
6.
C B
-2
A
IN
V
3.
(S
W
IN
V
3.
(N
E
R
IM
6.
17 LF 12" HDPE
@ 0.82%
6 LF 12" HDPE @ 0.77%
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Fi le
P at h
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD Project Management, Architecture, Landscape Architecture, Cemetery Planning, Civil Engineering, Land Survey:
STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Structural Engineering, Electrical Engineering:
Sacramento Valley National Cemetery Phase 2 Development
5810 Midway Rd, Dixon, CA 95620
921CM2007
Project Director
JUNE 27, 2018Revisions: Date:
HDR Engineering, Inc.
2365 Iron Point Rd. #300 Folsom, CA 95630 (916)-817-4924 Duane Hodgens
Irrigation:
Aqua Engineering, Inc.
375 Horsetooth Rd., Bldg. 2-202 Fort Collins, CO 80525 (970)-372-6104 Robert Beccard
Cost Estimating:
CPMI, Inc.
3265 Northwood Cir., Ste. 170 Eagan, MN 55121 (952)-854-3663 Bryan Bertrand
Geotechnical Engineering:
Terracon Consultants, Inc.
50 Goldenland Ct., Ste. 100 Sacramento, CA 95834 (916)-928-4690 Robert Holmer o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
Anderson Engineering of MN, LLC 13605 1st Ave. N., Ste. 100 Plymouth, MN 55441 (763)-412-4000 Michael Brandvold, Project Manager
OF
06 / 27 / 2018
STORM NETWORKS
100 & 200 PROFILES
CS301y:
\1
\1 v a oc fm p ha se d ev o f s ac ra m en to v al le y nc \D w g-
C 3d
\C iv il\
6_
D R
A
IN
A G
E
D E
TA
IL
S .d w g
/2 5/
2:
P
M
SCALE:1
STORM NETWORK 100 (CB115A - STMH103)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE)
SCALE:2
STORM NETWORK 100 (STMH103 - FES100)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE) SCALE:3
STORM NETWORK 101 (CB122 - STMH109)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE)
SCALE:4
STORM NETWORK 102 (CB119 - STMH109)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE) SCALE:5
STORM NETWORK 103
(CB106A - STMH106)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE) SCALE:6
STORM NETWORK 104
(CB110A - CB110B)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE) SCALE:7
STORM NETWORK 105
(CB113A - CB113B)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE) SCALE:8
STORM NETWORK 106
(STMH115 - CB115B)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE)
SCALE:9
STORM NETWORK 107
(CB122A - CBMH122B)
H:1"=30' V:1"=5' (30' x 42' PAPER SIZE) SCALE:10
STORM NETWORK 108
(CB116A - CB116B)
H…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.