This file is a set of construction drawings (DWGs) dated October 12, 2023, for solicitation 36C26126R0036 related to the renovation of an outpatient pharmacy and HVAC systems at a Department of Veterans Affairs facility under Veterans Integrated Service Network 21. The drawings serve as technical specifications and visual representations for the proposed construction work, providing detailed design documentation necessary for bidders to understand the scope of the renovation project and prepare accurate cost estimates and implementation plans.
The drawings contain architectural, mechanical, and systems design details required to execute the outpatient pharmacy renovation and HVAC upgrades. As technical construction documents, these drawings are essential contract attachments that establish the physical and operational requirements for the project. Contractors responding to this solicitation must review these drawings thoroughly to ensure their proposals address all specified construction standards, equipment installations, spatial configurations, and systems integration outlined in the design documentation.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION AT
FIRST FLOOR - BLDG. 650
TEMPORARY TRAILER
LOCATION
Engineers Architects
Submissions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.
PROJECT SITE MAP PROJECT LOCATION MAP
PROJECT IMAGE
/1 /2
:1
:3
A
M C
U s e rs \a p u lle n \D o c u m e n ts
\A V
A M a th e r-
O u tp a ti e n t P h a rm a c y a n d
H V
A C
-C A
-1 a p u lle n V
D X
T .r v t
G-001
COVER
1 7ANP
RENOVATION OF
OUTPATIENT PHARMACY
AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655 OCTOBER 13, 2023
100% BID DOCUMENTS
612A4-19-01619-103
RENOVATION OF OUTPATIENT PHARMACY AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655
VA PROJECT #: 612A4-19-016
RMC
DRAWING LIST
GENERAL
G-001 COVER 1 7
G-002 GENERAL INFORMATION 2 7
G-003 INFECTION CONTROL MATRIX 3 7
G-004 ICRA INFORMATION AND DETAILS 4 7
G-005 FIRST FLOOR INFECTION CONTROL AND PHASING PLAN 5 7
G-006 TRAILER LOCATION - SITE PLAN AND FLOOR PLAN 6 7
LS101 FIRST FLOOR LIFE SAFETY PLAN 7 7
STRUCTURAL
S-001 ABBREVIATIONS, SYMBOL LEGEND, AND GENERAL STRUCTURAL NOTES 1 6
S-002 SPECIAL INSPECTIONS 2 6
S-101 DEMO, FOUNDATION PLAN, VAULT ROOF PLAN 3 6
S-102 ROOF FRAMING PLAN 4 6
S-501 DETAILS 5 6
S-502 DETAILS 6 6
ARCHITECTURAL
A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 7
AD101 FIRST FLOOR DEMOLITION AND ICRA PLAN AND REFLECTED CEILING PLAN 2 7
A-101 FIRST FLOOR PLAN AND REFLECTED CEILING PLAN 3 7
A-104 ROOF PLAN 4 7
A-501 PARTITION TYPES AND TRANSITION DETAILS 5 7
A-601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 6 7
A-701 PLAN AND SECTION DETAILS 7 7
INTERIORS
I-001 PRODUCT SCHEDULES, SYMBOLS AND ABBREVIATIONS 1 14
I-101 FIRST FLOOR FINISH AND FLOOR PATTERN PLANS 2 14
I-131 FIRST FLOOR WALL PROTECTION PLAN AND DETAILS 3 14
I-141 FIRST FLOOR SIGNAGE PLAN 4 14
I-201 CASEWORK ELEVATIONS AND ENLARGED PLAN 5 14
I-202 CASEWORK DETAILS 6 14
I-401 INTERIOR ELEVATIONS - WALL PROTECTION 7 14
I-402 INTERIOR ELEVATIONS - EQUIPMENT 8 14
I-411 FIRST FLOOR OVERALL EQUIPMENT PLAN 9 14
I-421 FIRST FLOOR ENLARGED EQUIPMENT PLAN - A 10 14
I-422 FIRST FLOOR ENLARGED EQUIPMENT PLAN - B 11 14
I-423 ENLARGED EQUIPMENT PLANS 12 14
I-431 ENLARGED TOILET PLANS AND ELEVATIONS 13 14
I-601 EQUIPMENT SCHEDULE 14 14
FIRE SUPPRESSION
FX001 FIRE SUPPRESSION GENERAL INFORMATION 1 2
FX101 FIRST FLOOR FIRE SUPPRESSION PLAN 2 2
PLUMBING
P-001 PLUMBING GENERAL INFORMATION 1 3
P-101 FIRST FLOOR PLUMBING PLAN 2 3
P-501 PLUMBING DETAILS 3 3
MECHANICAL
M-001 MECHANICAL GENERAL INFORMATION 1 11
MD101 FIRST FLOOR MECHANICAL DEMOLITION PLAN 2 11
MH101 FIRST FLOOR HVAC PLAN 3 11
MH102 ROOF HVAC PLAN 4 11
MP101 FIRST FLOOR MECHANICAL PIPING PLAN 5 11
M-301 MECHANICAL SECTIONS 6 11
M-501 MECHANICAL DETAILS 7 11
M-502 MECHANICAL DETAILS 8 11
M-503 MECHANICAL DETAILS 9 11
M-504 MECHANICAL CONTROLS 10 11
M-601 MECHANICAL SCHEDULES 11 11
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 12
ES101 ELECTRICAL SITE PLAN 2 12
ED101 FIRST FLOOR ELECTRICAL AND TECHNOLOGY DEMOLITION PLAN 3 12
E-101 ELECTRICAL OVERALL WORK PLAN 4 12
EP101 FIRST FLOOR POWER PLAN 5 12
EL101 FIRST FLOOR LIGHTING PLAN 6 12
EM101 FIRST FLOOR MECHANICAL POWER AND TECHNOLOGY SYSTEMS PLAN 7 12
E-501 ELECTRICAL AND TECHNOLOGY DETAILS 8 12
E-601A SINGLE-LINE DIAGRAM 9 12
E-601B SINGLE-LINE DIAGRAM 10 12
E-602 EXISTING ELECTRICAL PANEL SCHEDULES 11 12
E-603 ELECTRICAL PANEL SCHEDULES 12 12
TECHNOLOGY
TK001 TECHNOLOGY GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 3
TK101 FIRST FLOOR TECHNOLOGY PLAN 2 3
TK501 TECHNOLOGY DETAILS 3 3
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES, SYMBOL LEGEND, AND RISER 1 4
FA101 FIRST FLOOR FIRE ALARM PLAN 2 4
FA102 ROOF FIRE ALARM PLAN 3 4
FA501 FIRE ALARM DETAILS 4 4
BLDG. 6
95% CONSTRUCTION DOCUMENTS REV. 1
95% CONSTRUCTION DOCUMENTS
95% CONSTRUCTION DOCUMENTS
65% DESIGN DEVELOPMENT
35% SCHEMATIC DESIGN
35% SCHEMATIC DESIGN
25% SCHEMATIC DESIGN
PRE-DESIGN
7/27/2022
4/25/2022
11/17/2021
8/25/2021
11/7/2020
9/14/2020
5/12/2020
3/17/2020
9 100% CONSTRUCTION DOCUMENTS 7/25/2023
10 100% BID DOCUMENTS 10/13/2023
24514
LICENSED
ARCHITECT
24514
LICENSED
ARCHITECT
DocuSign Envelope ID: 8E14BB13-53AD-439F-AE8F-5E89049111D3
10/12/2023
WALL SECTION
SYMBOL
INTERIOR ELEVATION
SYMBOL
COLUMN GRID
ELEVATION SYMBOL
REVISION NOTE
ENLARGED DETAIL CALLOUT
ROOM DESIGNATION
SYMBOL
BREAK LINE
ROOF SLOPE
DIRECTION SYMBOL
TYPICAL GRAPHIC SCALE
DETAIL #
PAGE #
DETAIL #
PAGE #
VIEW NORTH ARROW
A8.1
EXTERIOR ELEVATION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
A8.1
BUILDING SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
DETAIL SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
WALL GRID
(REPRESENTS
FACE OF EXISTING
WALL)
XX.X
XX.X
ELEVATION
0'-0"
ROOM
NAME
101A
NORTHNORTH
0 4 8 16
EXPOSED
PLUMBING AT
BARRIER
FREE
LAVATORIES
SHALL BE
INSULATED.
LEVER OPERATING
CONTROLLED
SOAP DISPENSER
NOTE: SINKS IN COUNTERS TO BE
MOUNTED WITH RIM NO MORE
THAN 2'-10" HIGH AND WITH AT
LEAST 2'-3" KNEE CLEARANCE.
CLEAR
TYPICAL ACCESSIBLE
CLEARANCE AT LAVATORY
TYPICAL ACCESSIBLE
LAVATORY AND MIRROR
1'-3" 1'-3"
M
IN
M A
X
M
A X
M
A X6
A
.F .F
MIN
8"
MAX
6"
M
IN9
M
IN
M
IN
M A
X
17" MIN
T O
B O
T T
O M
O F
R
E F
L E
C T
IV
S
U R
F A
C E
O F
M
IR
R
O R
O .C
O.C.
39" - 41"
3'-6" 1'-0"
9" O.C.
T O
T O
P
6" 3'-0"
ACCESSIBLE TOILET
WALL MOUNTED
1-1/2"
DIAMETER
GRAB BAR
TOILET TISSUE
DISPENSER
FIRE ALARM
CHIME WITH
VISUAL
ALARM LIGHT
FIRE ALARM
PULL STATION
FIRE ALARM
ANNUNCIATOR
FIRE ALARM
PAPER TOWEL
DISPENSER
2'-0" AT SIDEWALLS
AT COUNTER SINKS
1'-6" AT SIDEWALLS
AT LAVATORY
ACCESSIBLE
ROBE/COAT HOOK
ROBE/COAT
HOOK
TOILET ACCESSORIES
6"
4'-0" MAX TO
HIGHEST OPERABLE
POINT - IF FIRE
EXTINGUISHER
OVER 40 LBS
3'-6" MAX HT.
FIRE EXTINGUISHER
CABINET
ELECTRICAL CABINET
DUPLEX
OUTLET
SWITCH
THERMOSTAT
TELEPHONE
OR DATA
OUTLET
FIRE ALARM
PULL
INTERCOM
STATION
DUPLEX
OUTLET
COMPUTER
TERMINAL
MISC. WALL DEVICES
CLOCK
CLOCK
WALL MOUNTED TACKBOARD
AND MARKERBOARD
TELEVISION
OUTLET
WALL MOUNTED TV
F O
R S
T A
N D
IN
G
O
.C
TELEVISION
OUTLET
F O
R S
E A
T E
D
O
.C
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO
PARTICIPATE IN VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS SPECIFY OTHER CODES AND
STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
Codes, Standards and Design References
1. VA Sustainable Design Manual, August 2017
2. VA Parking Design Manual, November 2016
3. VA Site Development Design Manual February 2013
4. VA VHA Directive 1061, February 2021
5. VA Directive 7512, 3 August 2017
6. VA Fire Protection Design Manual, 2021
7. VA Plumbing Design Manual, May 2021
8. VA HVAC Design Manual, March 2022
9. VA Physical Security and Resiliency Design Manual, 2022
10. VA Lighting Design Manual, December 2022
11. VA Electrical Design Manual, December 2019
12. VA Interior Design Manual, November 2020
13. VA Physical Security Design Manual for VA Mission Critical Facilities, January 2020
14. VA Office of information & Technology Design Guide, February 2019
15. VA Telecommunications and Special Telecommunications Systems Design Manual, February 2016
16. VA Infrastructure Standard for Telecommunications Spaces Design Guide, August 2020
17. VA TIL Design Guide Chapter 268-Pharmacy Services, 2022-03
18. PG 18-13 VA Barrier Free Design Standard, February 2022
19. PG 18-4 VA Standard Details and Specifications
20. PG 18-3: VA Design Guidelines; Chapter 268-Pharmacy
21. PG-18-1: VA Master Construction Specifications
22. NFPA 101, Life Safety Code, 2021
23. NFPA 99, Health Care Facilities Code, 2021
24. NFPA 90A, Installation of Air Conditioning and Ventilating Systems, 2021
25. NFPA 88A, Standard for Parking Structure, 2019
26. NFPA 72, National Fire Alarm Code, 2022
27. NFPA 70, National Electrical Code, 2020
28. NFPA 13, Installation of Sprinkler Systems, 2022
29. ADA Standards for Accessible Design 2010,
30. 2021 International Code Council (ICC) , Uniform Building Code
31. International Standards for Hematopoietic Cellular Therapy Product Collection, Processing, and Administration, Eighth Edition
32. International Building Code, 2021
33. International Fire Code, 2021
34. International Mechanical Code, 2021
35. International Plumbing Code, 2021
36. International Energy Conservation Code, 2018
37. International Fuel Gas Code, 2021
38. Illuminating Engineering Society (IES) Lighting Handbook, 10th Edition
39. TVHS Energy Requirements and Design Guide, September 2014
40. Facilities Guidelines Institute: Guidelines for the Design and Construction of Hospitals 2018
41. ASME B31.9, Building Services Piping
42. ASHRAE Standard 170, Ventilation for Health Care Facilities, 2021
43. ASHRAE Handbooks, 2017 Fundamentals, 2019 HVAC Applications, 2020 HVAC Systems and Equipment
44. ASHRAE 90.1 – 2019 Energy Standard for Buildings Except Low-Rise Residential Buildings
45. SMACNA, HVAC Duct Construction Standards, Metal and Flexible
46. SMACNA, HVAC Air Duct Leakage Test Manual
47. ANSI/TIA/EIA 568-2019 Commercial Building Cabling Standards
48. ANSI/TIA/EIA 569-C-2015 Commercial Building Standards for Telecommunications Pathways and Spaces
49. ANSI/TIA-1179-2017, Telecommunications Spaces for Healthcare Facilities
50. BICSI, Telecommunications Distribution Methods Manual, 2014
51. Federal Information Processing Standards-FIBS-201-1: Personal Identity Verification (PIV) of Federal Employees and Contractors
52. U.S. Department of Veterans Affairs, H-18-8 Seismic Design Requirements, 1 November 2019, revised May 1, 2020
53. ACI 318-14, Building Code Requirements for Reinforced Concrete
54. ACI 360R-10, Specifications Guide to Design of Slabs-On-Ground
55. ASCE 7-16 Minimum Design Loads for Building and Other Structures
56. AISC 360-16, American Institute of Steel Construction Inc
57. AISC 325-17, Steel Construction Manual, 15th Edition
58. AISC 341-16, American Institute of Steel Construction Inc., Seismic Provisions for Structural Steel Buildings
59. AWS D1.1, Structural Welding Code – Steel
60. TMS 402/602-16, Building Code Requirements and Specifications for Masonry Structures
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION
FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY
HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1 /2
:1
:2
A
M C
U s e rs \a p u lle n \D o c u m e n ts
\A V
A M a th e r-
O u tp a ti e n t P h a rm a c y a n d
H V
A C
-C A
-1 a p u lle n V
D X
T .r v t
G-002
GENERAL INFORMATION
2 7ANP
RENOVATION OF
OUTPATIENT PHARMACY
AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655 OCTOBER 13, 2023
100% BID DOCUMENTS
612A4-19-01619-103
RMC
GENERAL SYMBOL LEGEND
Scale: 3/8" = 1'-0"
STANDARD MOUNTING HEIGHTS
CODE STANDARDS AND EXECUTIVE ORDERS
24514
LICENSED
ARCHITECT
24514
LICENSED
ARCHITECT
Engineers Architects
Submissions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.
/1 /2
:1
:2
A
M C
U s e rs \a p u lle n \D o c u m e n ts
\A V
A M a th e r-
O u tp a ti e n t P h a rm a c y a n d
H V
A C
-C A
-1 a p u lle n V
D X
T .r v t
G-003
INFECTION CONTROL MATRIX
3 7ANP
RENOVATION OF
OUTPATIENT PHARMACY
AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655 OCTOBER 13, 2023
100% BID DOCUMENTS
612A4-19-01619-103
RMC
24514
LICENSED
ARCHITECT
24514
LICENSED
ARCHITECT
PLASTIC WINDOW
SWIVEL CASTERS
WITH TWO
LOCKING BRAKES
MOBILE CART
A D
J U
S T
A B
L E
H E
IG
H
T
HEPA NEGATIVE
AIR UNIT
EXISTING WALL
EXISTING CEILING
FLEX DUCT
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
EXISTING CEILING SYSTEM
BASE - TO MATCH
EXISTING AREA
EXISTING FLOOR
UNDERSIDE OF EXISTING
DECK
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L D
V E
R
IF
Y
/2
5"
3 5/8" 16 GAUGE METAL
STUDS @ 16" O.C. WALL TO
EXTEND TO UNDERSIDE OF
DECK
B
FIRE RESISTANT SEALANT,
BOTH SIDES
SMOKE RATED
3 5/8" INSULATED WALL WITH
16 GAUGE METAL STUDS @
16" O.C. WALL TO EXTEND TO
UNDERSIDE OF DECK
5/8" FIRE RESISTANT GYPSUM
BOARD
EXISTING
CEILING SYSTEM
BASE - TO MATCH
EXISTING AREA
EXISTING FLOOR
UNDERSIDE OF EXISTING
DECK
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L D
V E
R
IF
Y
W A
L L
H E
IG
H
T V
A R
IE
S
F
IE
L D
V E
R
IF
Y
A
FIRE RESISTANT SEALANT,
BOTH SIDES
NON RATED
CONSTRUCTION SIDE
HEPA NEGATIVE AIR UNIT. DUCT
TO EXTERIOR WHEN WINDOW IS
NOT AVAILABLE. VERIFY DUCT
ROUTE WITH COR.
FINISHED FLOORING TO BE KEPT
CLEAN. FLOORS NOT BEING REPLACED
MUST BE PROTECTED. COVER WITH
ROSIN PAPER / FIRE RATED PLYWOOD.
WHEN WINDOW IS AVAILABLE:
FIRE RATED PLYWOOD,
TEMPORARY. SALVAGE
PROTECT AND STORE
EXISTING WINDOW TO BE RE-
INSTALLED AFTER
CONSTRUCTION IS
COMPLETE.
V .I
.F
V .I
.F
V.I.F.
V .I .F
E X
IS
T
IN
G
W A
L L
V .I .F
E X
IS
T
IN
G
W A
L L
ISLM TEMPORARY BARRIER TAG
PROJECT:
PRIME CONTRACTOR:
SUB CONTRACTOR:
EMERGENCY CONTACT NO.:
BARRIER INSTALLATION DATE:
BARRIER EXPIRATION DATE:
FIRE EXTINGUISHER ON
PORTABLE FLOOR
BRACKET (ILSM MAY
REQUIRE MORE THAN
ONE).
PROVIDE STICKY
MATS (CHANGED END
OF SHIFT OR MORE IF
NECESSARY TO
MAINTAIN
CLEANLINESS).
HEPA NEGATIVE
AIR UNIT
ISOLATE AND COVER ALL
SUPPLY DIFFUSERS NOT
IN OPERATION DURING
PROJECT – COORDINATE
WITH COR
COVER ALL RETURNS
AT THE
GRATE/DIFFUSERS
F L E
X D
U C
T
SUSPENDED PLASTIC
ZIPPER WALL
CURTAIN BARRIER
POST ICRA, ILSM, FIRE
INPECTION SHEETS
VISIBLE TO PUBLIC
FIRE PULL
STATION WITH
AUDIO / VISUAL
G-004
_____ 4
G-004
ILSM SIGNAGE
INTERIM LIFE SAFETY MEASURES IN EFFECT
FOR PHARMACY RENOVATION BUILDING 650,
FIRST FLOOR
THIS EXIT IS CLOSED AND LEADS TO A
CONSTRUCTION AREA.
PLEASE USE ALL ALTERNATE EXITS AS MARKED.
1' - 5"
1/2"1/2"
/2
/2
/2
/2
/2
/2
EQ.EQ.
DUST CONTROL PLAN NOTES
1. THE VAMC INFECTION CONTROL GROUP HAS CONFIRMED THE
DESIGNATION FOR THIS PROJECT IS LEVEL IV FOR THE CLASS OF
PRECAUTIONS OR LEVEL OF INFECTION CONTROL ACTIVITIES. HARD
SURFACE BARRIERS SHALL BE USED EXCEPT IN THE AREA INDICATED ON
THE PHASING PLAN WITH PLASTIC BARRIERS (MINIMUM 4MIL) TO SEAL AREA
FROM NON-WORK AREA AS LONG AS THE SPRINKLER SYSTEM IS INTACT AND
ACTIVE.
1A. TIGHT SEALS SHALL BE MAINTAINED AT THE FULL PERIMETER OF
WALLS AND WALL PENETRATIONS. ANY DUST SHALL BE IMMEDIATELY
CLEANED IF TRACKED OUTSIDE OF THE CONSTRUCTION BARRIER. UPON
COMPLETION OF THE CONSTRUCTION PHASE, DUST BARRIERS SHALL BE
REMOVED CAREFULLY TO MINIMIZE SPREADING OF DUST AND THE
CONTRACTOR SHALL HAVE TEMPORARY DUST PROTECTION IN PLACE
BEFORE REMOVAL OF A PERMANENT BARRIER.
AFTER EACH PHASE, PERFORM TASKS STATED IN NOTE 6A.
2. PROVIDE STICKY MATS AND BLANKET AT THE PLASTIC BARRIER
ENTRANCE SPACES (CONSTRUCTION ANTEROOM) AND CHANGE DAILY OR
MORE OFTEN AS NEEDED TO PREVENT THE SPREAD OF DUST AND DEBRIS
INTO ADJACENT CLEAN SPACE.
INTERNAL DEMOLITION AND CONSTRUCTION ACTIVITIES DUST AND DEBRIS
CONTROL
3. USE CORRIDOR C1-208 AS PRIMARY CONSTRUCTION ACCESS.
3A. TRAFFIC CONTROL: DESIGNATED ENTRY AND EXIT PROCEDURES
SHALL BE DEFINED. EGRESS PATHS SHALL BE FREE OF DEBRIS;
DESIGNATED ELEVATORS SHALL BE USED DURING SCHEDULED TIMES; AND
ONLY AUTHORIZED PERSONNEL SHALL BE ALLOWED TO ENTER THE
CONSTRUCTION ZONE. SIGNAGE SHALL DIRECT PEDESTRIAN TRAFFIC
AWAY FROM THE CONSTRUCTION AREA AND MATERIALS.
4. CONTRACTOR SHALL USE TWO CARTS TO TRANSFER CONSTRUCTION
MATERIAL IN AND OUT OF THE PROJECT - A CLEAN CART SHALL BE USED;
THE NOT-SO-CLEAN CART SHALL BE USED BETWEEN THE MAIN ENTRY AND
THE CONSTRUCTION STAGING/PREP AREA.
4A. DEMOLITION DEBRIS: DEBRIS SHALL BE REMOVED IN CARTS WITH
TIGHTLY FITTED COVERS, USING DESIGNATED TRAFFIC ROUTES.
EFFORTS SHALL BE MADE TO MINIMIZE USE OF ELEVATORS WITH AN
EMPHASIS ON TRANSPORT DURING THE LOWEST PERIOD OF ACTIVITY.
DEBRIS SHALL BE REMOVED DAILY AND AT TIMES SPECIFIED BY THE VAMC.
IF CHUTES ARE USED TO DIRECT DEBRIS OUTSIDE, HIGH EFFICIENCY
PARTICULATE AIR (HEPA) FILTERED NEGATIVE AIR MACHINES SHALL BE
USED, AND THE CHUTE OPENING SHALL BE SEALED WHEN NOT IN USE.
FILTERS SHALL BE BAGGED AND SEALED BEFORE BEING TRANSPORTED OUT
OF THE CONSTRUCTION AREA. THE CONTRACTOR SHALL NOT HAUL DEBRIS
THROUGH PATIENT-CARE AREAS WITHOUT PRIOR APPROVAL OF THE COR.
4B. EXTERIOR WINDOWS: WINDOWS SHALL BE SEALED TO MINIMIZE
INFILTRATION FROM ANY ADJACENT EXCAVATION DEBRIS.
4C. ALL EQUIPMENT REMAIN IN THE ORs AND ASSOCIATED ROOMS SHALL
BE COVERED AND PROTECTED PRIOR STARTING EACH CONSTRUCTION
PHASE.
VENTILATION AND ENVIRONMENTAL CONTROLS
5. AIR SYSTEM FLOW: THE COR VERIFY AND ACKNOWLEDGE
CONTRACTOR WHETHER THE CONSTRUCTION AREA USES FRESH/OUTSIDE
OR RE-CIRCULATED AIR; FILTERS SHALL BE ADDED OR RETURN VENTS
COVERED AS NEEDED WITH FILTER MATERIAL OR PLASTIC. AIR MUST FLOW
FROM CLEAN TO DIRTY AREAS.
5A. NEGATIVE AIR PRESSURE: THE AIR WITHIN THE CONSTRUCTION AREA
SHALL BE NEGATIVE WITH RESPECT TO SURROUNDING AREAS AND WITH NO
DISRUPTION OF AIR SYSTEMS OF ADJACENT AREAS. USE OF THE NEGATIVE
AIR PRESSURE SYSTEM WITHIN THE ENCLOSURE TO REMOVE DUST SHALL
PASS AIR THROUGH AN INDUSTRIAL GRADE, PORTABLE HEPA FILTER
CAPABLE OF FILTRATION RATES OF 300-800 CUBIC FEET PER MINUTE
(FT3/MIN), OR EXHAUST AIR DIRECTLY TO THE OUTSIDE IF APPROVED BY
VAMC. IF EXHAUST SHALL BE TIED INTO A RE-CIRCULATED AIR SYSTEM, A
PRE-FILTER AND HEPA FILTER SHALL BE USED BEFORE EXHAUST TO
PREVENT CONTAMINATION OF THE DUCTS.
5B. ADJACENT AREAS: THE STATUS OF SEALED PENETRATIONS AND
INTACT CEILING SHALL BE VERIFIED DAILY.
5C. AIR EXCHANGE RATES AND PRESSURE RELATIONSHIPS: VAMC AND
CONTRACTOR SHALL VERIFY AND MAINTAIN PROPER RATES IN CRITICAL
AREAS NEAR CONSTRUCTION ACTIVITY AND ENSURE AIR IS NOT BEING RE-
CIRCULATED WITHOUT FILTRATION FROM THE CONSTRUCTION AREA
ELSEWHERE. PROVIDE AIR PRESSURE TESTING THROUGHOUT THE
PROJECT IN THE FREQUENCY AS IDENTIFIED BY THE COR.
CONTAMINATION OF PATIENT ROOMS, SUPPLIES, EQUIPMENT AND RELATED
AREAS
6. WORKSITE CLOTHING: CONTRACTOR PERSONNEL CLOTHING SHALL BE
FREE OF LOOSE SOIL AND DEBRIS BEFORE LEAVING THE CONSTRUCTION
AREA. IF PROTECTIVE APPAREL IS NOT WORN (E.G., COVERALLS, FOOTGEAR
AND HEADGEAR) A HEPA-FILTERED VACUUM SHALL BE USED TO REMOVE
DUST FROM CLOTHING BEFORE LEAVING THE BARRICADE. IF PROTECTIVE
APPAREL IS UTILIZED, THE CONTRACTOR SHALL CONSTRUCT A SPACE OR
ANTEROOM FOR CHANGING CLOTHING AND STORING EQUIPMENT
(DESIGNATED AREA. ALL EQUIPMENT, TOOLS, TOOL CARTS, AND MATERIALS
TRANSPORTED THROUGH OCCUPIED AREAS SHALL BE MADE FREE FROM
DUST AND MOISTURE BY VACUUMING AND WET WIPING BEFORE THEIR
REMOVAL FROM THE CONSTRUCTION ZONE OR WORK AREA.
6A. POST CONSTRUCTION: DO NOT REMOVE BARRIERS AND KEEP ALL
HVAC ISOLATION UNTIL CONTRACTOR HAS CLEANED CONSTRUCTION SITE,
VA EMS STAFF HAS DONE A TERMINAL CLEANING, AND VA INFECTIOUS
DISEASE CONTROL HAS INSPECTED AND APPROVED THE CLEANING.
POLICY LETTER EC-51
7. REFER TO SPEC SECTION 01 01 10 FOR EC-51 SAFETY AND HEALTH
POLICY AND PROCEDURES DURING CONSTRUCTION ACTIVITIES.
8. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH ALL ICRA
REQUIREMENTS INCLUDING THE SUBMITTAL OF ICRA PERMITS AND/OR
FORMS TO THE COR PRIOR TO THE COMMENCEMENT OF ANY WORK.
ICRA NOTES
A
S E
E S
C H
E D
U L E
SCHEDULE
SEE
2" 2"
SCHEDULE
SEE
S E
E S
C H
E D
U L E
" DOOR HARDWARE SET NO. 1:
HINGES: 3 BUTT HINGES
LOCKSET: 1 STORAGE FUNCTION LOCKSET
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1 /2
:1
:2
A
M C
U s e rs \a p u lle n \D o c u m e n ts
\A V
A M a th e r-
O u tp a ti e n t P h a rm a c y a n d
H V
A C
-C A
-1 a p u lle n V
D X
T .r v t
G-004
ICRA INFORMATION AND DETAILS
4 7ANP
RENOVATION OF
OUTPATIENT PHARMACY
AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655 OCTOBER 13, 2023
100% BID DOCUMENTS
612A4-19-01619-103
RMC
Scale: 1/2" = 1'-0"
ICRA MOBILE CONTAINMENT CART
Scale: 3/4" = 1'-0"
ICRA BARRIER WALL TYPE
Scale: 1/2" = 1'-0"
SECTION AT CONSTRUCTION PLAN
Scale: 1/2" = 1'-0"
TYPICAL CONSTRUCTION PLAN LAYOUT
Scale: 3" = 1'-0"
ILSM CONSTRUCTION EGRESS SIGNAGE
DOOR SCHEDULE
DOOR DOOR FRAME
HDWR SETNO. WIDTH HEIGHT THICK MAT'L ELEV MAT'L ELEV
FIRST FLOOR
100-1 3' - 6" 7' - 0" 1 3/4" WD A HM 1 1
100-2 3' - 6" 7' - 0" 1 3/4" WD A HM 1 1
100-3 3' - 6" 7' - 0" 1 3/4" WD A HM 1 1
DOOR ELEVATION FRAME ELEVATION
24514
LICENSED
ARCHITECT
24514
LICENSED
ARCHITECT
UP
EXISTING WALL TO REMAIN
EXISTING DOOR TO REMAIN
DEMOLISH WALL
DEMOLISH DOOR
DEMOLISH WINDOW
EXISTING WINDOW TO REMAIN
ICRA LEGEND
TEMPORARY DOOR
TYPE "B" TEMPORARY WALL
TYPE "D" TEMPORARY WALL
AREA OF WORK
STICKY MAT LOCATION
CONSTRUCTION ACCESS ROUTE
INITIAL PHASE
5.8
F
AA
D2
E3 bb
6 7 7.8 8 8.5 9 10 103 11 104 12 aa
E
D
C
B
5.2
BB
VAULT
CONSULT
RX RECEIVING
FILLING/
ASSEMBLY &
DISPENSING
RECEIVING
CLINIC
CORRIDOR
OFFICE
STAFF TLT
BREAKROOM
OFFICE
RECEPTION
STORAGE
RESEARCH
WAITING
CORRIDOR
C1-208
CORRIDOR
C1-103
STAIR
#4
ELEVATOR
LOBBY
1B020A
101 9.5
10.2
D.5
WORK AREA
1D302 WORK AREA
1D300
WOMEN'S
RESTROOM
1E002
MEN'S
RESTROOM
1E005
LAB
1D303
MECH
1D645
HALLWAY
1D604
PROCEDURE
1D618
STORAGE
1D619
OFFICE
1D621
TLT
1D620
STAFF
LOUNGE
1D511
STORAGE
1D513
OFFICE
1D517
OFFICE
1D519
OFFICE
1D521
OFFICE
1D523
LAB WORK
AREA
1D510
WAITING
1D500
TLT
1D507TLT
1D515 RECEPTION
1D505
MICROBIOLOGY
1D516
OFFICE
1D407
ELECT
1D405
OFFICE
1D516A
BLOOD BANK
1D518
EXAM
1D419
STAINING
1D522
HISTOLOGY
1D520
RM
FOYER
C1-210
OFFICE
1D420
EXAM
1D418
EXAM
1D410
OFFCIE
1D312
CONTROL
1D308
LAB
1D305
EXAM
1D406
OFFICE
1B131
OFFICE
1B239A
M
IN
M
IN
M
IN
M
IN
M
IN
100-3
100-2
100-1
HAC
1D400
TLT
1D400A
TLT
1D404
CONSTRUCTION
ACCESS/ DELIVERY
DOOR
PROVIDE SIGN ON
DOOR INDICATING
"NO ACCESS DURING
CONSTRUCTION"
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1 /2
:1
:3
A
M C
U s e rs \a p u lle n \D o c u m e n ts
\A V
A M a th e r-
O u tp a ti e n t P h a rm a c y a n d
H V
A C
-C A
-1 a p u lle n V
D X
T .r v t
G-005
FIRST FLOOR INFECTION CONTROL
AND PHASING PLAN
5 7ANP
RENOVATION OF
OUTPATIENT PHARMACY
AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655 OCTOBER 13, 2023
100% BID DOCUMENTS
612A4-19-01619-103
RMC
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
Scale: 1/8" = 1'-0"
FIRST FLOOR INFECTION CONTROL PLAN
NORTH
0 4 8 16
A. SEE SHEET G-003 FOR ICRA DETAILS, NOTES
AND INTERSTITIAL ICRA NOTES.
B. KEY NOTES AND DRAWINGS ARE INTENDED TO
GRAPHICALLY REPRESENT GENERAL WORK
AND DO NOT PORTRAY FULL SCOPE OF THE
PROJECT IN ACCORDANCE WITH
SPECIFICATION. SEE SPECIFICATIONS FOR
DETAILED REQUIREMENTS.
C. REMOVE EXISTING CONSTRUCTION AS
DESIGNATED HEREIN AND CLEAR AREA OF
DEBRIS PRIOR TO PROCEEDING WITH NEW
CONSTRUCTION.
D. EXISTING EQUIPMENT REMOVED SHALL BE
PROPERLY DISPOSED OF OFF MEDICAL CENTER
GROUNDS.
E. PATCH WALL OPENING SHALL MATCH THE
INTEGRITY AND FINISH OF ADJACENT
CONSTRUCTION UNLESS INDICATED
OTHERWISE.
F. NOTIFY COR OF ANY DEMOLITION REQUIRED
AND NOT INDICATED FOR INSTALLATION OF
ELECTRICAL OR DATA ITEMS. AFTER SUCH
DEMOLITION AND INSTALLATION, PATCH OR
REPLACE MATERIALS AND FINISHES TO MATCH
EXISTING. SEE DEMOLITION SPECIFICATION.
G. THE INFORMATION CONTAINED IN THESE
DEMOLITION DOCUMENTS DEFINES GENERAL
SCOPE ONLY AND DOES NOT RELIEVE THE
CONTRACTOR OF THE RESPONSIBILITY OF
PROVIDING ALL DEMOLITION REQUIRED FOR
THE COMPLETION OF THE PROJECT.
H. REFER TO THE ELECTRICAL DRAWINGS FOR
FURTHER INFORMATION REGARDING
DEMOLITION OF ELECTRICAL SYSTEMS.
I. BEFORE THE START OF WORK, IDENTIFY ANY
REQUIRED DEMOLITION BEYOND THE
IDENTIFIED PROJECT SCOPE WHETHER ABOVE,
BELOW OR OUTSIDE PROJECT AREA. NOTIFY
AND COORDINATE WITH THE COR, PROVIDE
DEMOLITION OF THESE AREAS AND PATCH THE
SAME AS A PART OF THE SCOPE OF THE
PROJECT.
J. ALL DEMOLITION WORK SHALL BE PERFORMED
WITH DUE CARE AND DILIGENCE IN ORDER TO
PREVENT ARBITRARY DAMAGE OR
INTERRUPTION OF SERVICE OR CONCEALED
UTILITIES INTENDED TO REMAIN IN SERVICE.
DISCOVERY OF UTILITIES OR CONDITIONS
LOCATED DIFFERENTLY FROM THAT INDICATED
OR THAT ARE NOT IDENTIFIED. SHALL BE
REPORTED TO THE CONTRACTING OFFICER.
K. VERIFY CONSTRUCTION ROUTE WITH COR
PRIOR TO CONSTRUCTION.
L. EXISTING 2 HOUR FIRE RATED WALLS TO BE
REDUCED TO ONE HOUR FIRE RATED WALLS AT
PHARMACY.
M. PLAN ALL UTILITY SHUT DOWNS AND
DEMOLITION TO INCLUDE NEW VALVES AND
ATTACHMENTS FOR NEW WORK AT THE
RENOVATION SITE.
24514
LICENSED
ARCHITECT
24514
LICENSED
ARCHITECT
DN
DN
DN
DN
CANTEEN PARKING
TEMPORARY
OUTPATIENT
PHARMACY (3
TRAILERS LINKED
TOGETHER)
TEMPORARY WAITING
OUTPATIENT PHARMACY
(2 TRAILERS LINKED
TOGETHER)
PHARMACY
VAULT
G-006
BLDG 649
BLDG 647
BLDG 650
HOSPITAL W
AY
15'-4"
(3 T
R A
I L E
R S
W
ID
E
60'-0"
(2 T
R A
I L E
R S
W
ID
E
60'-0"
WAITING ROOM
STAFF
TOILET
RECEPTION
FILLING/ASSEMBLY
VAULT
OFFICE
VISITOR
TOILET
DUTCH DOOR
LANDING
LANDING
LANDING
LANDING
LANDING
T1
T2 T3
T4
T5
T6
T8
T7
T9T11
T10
EXIT DOOR
COUNTER VISION
PANELS WITH SPEAKER
2'-0"
11'-0"26'-6"
7'-6" 15'-9"
VAULT DOOR WITH
DAY GATE 1
G-006
TRAILER FLOOR
3" RIGID INSULATION
TAPERED INSULATION
TPO ROOFING
1 1/2" METAL DECK
.060 ALUM GRAVEL STOP
ELEV. 10'-10"10" COLD FORM
RAFTER FRAMING
AT 8" O.C. WITH
CONNECTION
ANGLES
5/8" GYPSUM WALL
BOARD - PAINT
GYPSUM WALL
BOARD CEILING
9 GA. EXPANDED METAL MESH
WELDED EVERY 6" TO THE
COLD FORM STUDS
STUD CONNECTION TO SLAB
(TYP.): PROVIDE STEEL ANGLE
BOLTED TO STUD W/EXPANSION
ANCHORS TO SLAB
5 1/2" CONCRETE
FLOOR ON 1 1/2"
METAL DECK OR 6"
CONCRETE PLANK
2" RIGID INSULATION
1'-4" CONCRETE
FOUNDATION WALL
W/FOOTING
GRADE
ATTACH METAL DECK TO
EACH STUD WITH (2) #12
SCREWS IN EACH FLUTE.
FASTEN SIDE LAP WITH #12
SCREW @ 12" O.C. SCREWS
TO BE STAINLESS STEEL OR
COATED WITH CORROSION
PREVENTIVE COATING
EIFS AND 2" RIGID INSULATION
8" CFMF STUDS @ 8" O.C.
W/8" BATT INSULATION
1 1/2" METAL DECK - TYPE 1.5
B, 22 GA BODY BY VULCRAFT
OR EQUAL
5/8" EXT. GYPSUM
SHEATHING
9 GA. EXPANDED
METAL MESH
NOTES:
1. PROVIDE 16 GA. HM DOOR & FRAME AT EXTERIOR
DOORS
2. PROVIDE SOLID CORE WOOD LAMINATE AT
INTERIOR DOORS
3. SEE SPECIFICATIONS SECTION 015000 FOR
REMAINDER OF DOOR REQUIREMENTS
3'-0"
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1 /2
:1
:5
A
M C
U s e rs \a p u lle n \D o c u m e n ts
\A V
A M a th e r-
O u tp a ti e n t P h a rm a c y a n d
H V
A C
-C A
-1 a p u lle n V
D X
T .r v t
G-006
TRAILER LOCATION - SITE PLAN AND
FLOOR PLAN
6 7ANP
RENOVATION OF
OUTPATIENT PHARMACY
AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655 OCTOBER 13, 2023
100% BID DOCUMENTS
612A4-19-01619-103
RMC
NORTH
0 4 8 16
Scale: 1/16" = 1'-0"
SITE PLAN
N O
R T
H0 4 8 16
Scale: 1/8" = 1'-0"
TEMPORARY TRAILER FLOOR PLAN
Scale: 1/2" = 1'-0"
TYPICAL SECTION AT VAULT
RAMP NOTES:
1. ALL MATERIALS TO BE ALUMINUM .
2. GRADE TO BE 1" IN 20' (MAX).
3. PROVIDE 1 1/2" PIPE HANDRAIL AND POSTS WITH 1/2"
DIAMETER PIPE BALUSTERS @ 4" O.C. (MAX).
4. PROVIDE 1 1/2" FLOOR GRATING.
DOOR ELEVATION
24514
LICENSED
ARCHITECT
OFFICE
1B239A
OFFICE
B131
OFFICE
1B239
OFFICE
1B033
CONFERENCE
1B041
TELE/DATA
1B235
HALLWAY
1B234ELECT
1B237
OFFICE
1B251A
Room
1B251
Room
1B051
CLOSET
1B051C
OFFICE
1B051B
OFFICE
1B167
OFFICE
1B051A
CORRIDOR B
WORK
AREA
1D302
WORK
AREA
1D300
WOMEN'S
TLT
1E002
MEN'S
TLT
1E005
ELEC
1E122
CORRIDOR
C1-301
SHOP
LAB
1D303
STORAGE
MAIN
LOBBY
1B238
EXAM
1D923
EXAM
1D927
OFFICE
1D919
OFFICE
1D920
VITALS
1D922
DTR
1D924
HAC
1D925
EXAM
1D826
OFFICE
1D827
EXAM
1D825
EXAM
1D824
EXAM
1D915
STORAGE
1D918
C O
R R
ID
O
R C
-2
EXAM
1D913
EXAM
1D823
EXAM
1D821
CORRIDOR
C1-201
STAFF
TLT
1D820
UTILITY
1D822
CORRIDOR
C1-202
OFFICE
1D914
STORAGE
1D818
EXAM
1D911
EXAM
1D909
EXAM
1D907
EXAM
1D905
TLT
1D903
WAITING
1D901
RECEPTION
1D902
CLINICAL
PHARMACY
1D803
CLINICAL
PHARMACY
1D804
HALLWAY
1D808
TLT
1D904
EXAM
1D912
EXAM
1D910
EXAM
1D906
OFFICE
1D817OFFICE
1D816
CORRIDOR
C1-104
ELECT
1D801
WAITING
1C902
OFFICE
1C901
CENTRAL
CHECK-IN
1C700
TELECOM
1C900
OFFICE
1C700A HAC
1C700C
BREAK
RM
1C700D
OFFICE
1C905B
TREATMENT
RM
1C908
TLT
1C909 STAFF
TLT
1C804
TLT
1C700B
TREATMENT
RM
1C910
DECONTAM
1C911
OFFICE
1C808
TLT
1C910A
TREATMENT
RM
1C914
BREAKROOM
1C912
EXAM
1C812
OFFICE
1C814
OFFICE
1C915
EXAM
1C924
EXAM
1C828
OFFICE
1C927
HAC
1C929
OFFICE
1C928
OFFICE
1C925
EXAM
1C829
OFFICE
1C827
CORRIDOR
C1-112
EXAM
1C825
OFFICE
1C729
OFFICE
1C727
EXAM
1C725
OFFICE
1C629
EXAM
1C627
OFFICE
1C531
EXAM
1C529
OFFICE
1C527
OFFICE
1C525
OFFICE
1C429
EXAM
1C427
EXAM
1C425
EXAM
1C327
EXAM
1C325
TLT
1C328
EXAM
1C239
EXAM
1C237
OFFICE
1C235
OFFICE
1C233
HAC
1C231
ABI
EXAM
1C230
EXAM
1C228
ENT
EXAM
1C211
C O
R R
ID
O
R C
-1
OFFICE
1C230A
EXAM
1C209
UROLOGY
LAB
1C226
EXAM
1C210
EXAM
1C208
EXAM
1C207
SUBWAIT
1C206
OFFICE
1C205
EXAM
1C309
EXAM
1C313
EXAM
1C316
EXAM
1C311
STORAGE
1C205A
MEN'S
TLT
1B006
WOMEN
TLT
1B004
FOYER
C1-104ASUBWAITING
1C301
EXAM
1C303
PODIATRY
1C307
HAC
1B010
OFFICE
1B012
HOLDING
1B018C
EXAM
1C809
OFFICE
1C811
EXAM
1C813
EXAM
1C824
EXAM
1C708
EXAM
1C710
EXAM
1C712
OFFICE
1C728
EXAM
1C706
EXAM
1C704
EXAM
1C702
EXAM
1C701
OFFICE
1C600
EXAM
1C604
OFFICE
1C703
EXAM
1C705 EXAM
1C606
EXAM
1C610
GAMMA
CAMERA
1C516
CAMERA
ROOM
1C713
STRESS
1C616
C O
R R
ID
O
R C
-1
LOUNGE
1C424
UTILITY
1C413
PODIATRY
1C314
EXAM
1C411
EXAM
1C312
OFFICE
1C310
OFFICE
1C409
EXAM
1C407
EXAM
1C308
OFFICE
1C306
OFFICE
1C406
EXAM
1C403
EXAM
1C304
OFFICE
1C401
T/D 1C302
CORR.
C1-105
WAITING
1C500
ELECT
1C601
TLT
1C504
RECEPTION
1C508
P.E.T.
SCAN
1C510
OFFICE
1C512
RECEPTION
1C507
CORRIDOR
C1-113
CONTROL
ROOM
1C510A TLT
1C514
CONTROL
1C603
OFFICE
1C509
EXAM
1C406
OFFICE
1C408
EXAM
1C511
BONE
DENSITY
1C513 TREATMENT
1C410
HOT LAB
1C515
INJECTION
1C517
EXAM
1C428
MECH
1D645
HAC
1D728CORRIDOR
C1-206
OFFICE/EXAM
1D726
EXAM
1D724
OFFICE
1D722
OFFICE
1D721
EXAM
1D717
EXAM
1D715
OFFICE
1D713
EXAM
1D711
EXAM
1D716 EXAM
1D723
OFFICE/EXAM
1D725
EXAM
1D714
EXAM
1D712
OFFICE
1D710
OFF/EX
1D708
OFFICE
1D706
VITAL/RECEPTIONS
1D706
WAITING
1D701
REST RM
1D703
EXAM
1D707CONF RM
1D806
OFFICE
1D812
STORAGE
1D810B
EXAM
1D811
OFFICE
1D809
CLINICAL
PHARM.
1D807
CLINICAL
PHARM.
1D805
WAITING
1D601
TOILET
1D606
CONF.
1D607
BARIATRIC
EXAM
1D608
EXAM
1D609
BARIATRIC
TOILET
1D610
WOMEN'S
HEALTH
EXAM
1D611
OFFICE
1D612
EXAM
1D614
EXAM
1D615
SOCIAL
WORK
1D617
HALLWAY
1D604
PROCEDURE
1D618
STORAGE
1D619
OFFICE
1D621
TLT
1D620
STAFF
LOUNGE
1D511
STORAGE
1D513
OFFICE
1D517
OFFICE
1D519
OFFICE
1D521
OFFICE
1D523
LAB
WORK
AREA
1D510
RM
RM
RM
RM
RM
RM
RM
WAITING
1D500
TLT
1D507
TLT
1D515
RECEPTION
1D505
MICROBIOLOGY
1D516
OFFICE
1D407
ELECT
1D405
OFFICE
1D516A
BLOOD
BANK
1D518
EXAM
1D419
STAINING
1D522
HISTOLOGY
1D520
RM
FOYER
C1-210
OFFICE
1D420
EXAM
1D418
EXAM
1D410 OFFCIE
1D312
CONTROL
1D308
LAB
1D305
EXAM
1D406
EVIDENCE
STORAGE
1B018A
FIREARM
STORAGE
1B018B
POLICE
1B100
EN
LOCKER
1B025
WMN
LOCKER
1B024
AC
CLERK
1B064
TRAVEL
CLERK
1B062
SPECIALIST
1B032 SPECIALIST
1B033 SPECIALIST
1B034
WHEELCHAIR
STORAGE
1B065A STORAGE
1B035
STORAGE
1B070
RM
MEN'S
TLT
1B057C
JANITOR
CLOSET
1B057A
MHV
OPEN
OFFICE
1B069
RM
ELEC
ROOM
1B093
IT ROOM
1B098
EEO &
ADR
MANAGER
1B092
EE &
ADR
OFFICE
1B090
EE &
ADR
SPECIALIST
1B082
SERVICE
OFFICE
1B074
TELE/
DATA
1B077
WOMEN'S
TLT
1B057B
RM
RM
RM
RM
STAIR
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
IRM
COMPUTER
1E272
ELECT
1E270
RM
RM
RM
RM
RM
SOILED/DECON
1E282
HAC
1E280LOUNGE
1E274
TLT
1E277A
TLT
1E279A
LOCKER
1E279
LOCKER
1E277
RM
DISPATCH
1E255
RM
EQUIP
WASH
1E266
EQPM
REPAIR
1E259
LAB
STORAGE
1E243
OFFICE
1E253
ELEC
1E241
LOCKER
1E247A
TLT
1E247B
AUTOPSY
1E247
HAC
1E265
RM
RM
FOYER
C1-304
RM
RM
RM
RM
RM
RM
RM
#### RM
RM
RM
RM
RM
STAFF
DINING
STORAGE
RM
RM
RM
STORAGE
STORAGE
RM
KITCHEN
LOCKER
ROOM
PA OPEN
OFFICE
1B027
HAC
1D400
TLT
1D404 TLT
1D400A
ENTRY
1B236
EGRESS PATH
HAZARDOUS LOCATION
FIRE EXTINGUISHER BRACKET
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
EMERGENCY RESPONSE REFERENCE
CONTROLLED ACCESS - ALWAYS
UNLOCKED IN DIRECTION OF EGRESS
KNOX BOX
DELAYED EGRESS W/ ALARM
CA
DE
KB
FEB
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH
EGRESS
CAPACITY
EGRESS WIDTH
(per IBC 1005.1)
COMMON PATH OF
TRAVEL
(per IBC Chapter 10)
EXIT ACCESS TRAVEL
(per IBC TABLE 1017.3)
EXIT DOORS = 36"/(0.20) = 180 PPL
75' - 0" MAXIMUM
300' - 0" MAXIMUM DISTANCE
ACTUAL TRAVEL DISTANCE"
EXIT 1 = 189' - 0"
EXIT 2 = 221' - 6"
OCCUPANT LOAD
(per NFPA TABLE 7.3.1.2)
OCCUP. = 4,295 GSF/150 = 29 PPL
TOTAL OCCUP. = 29 PEOPLE
REQUIRED # OF EXITS
(per IBC 1007)
1 EXIT REQUIRED IF UNDER 49
ACTUAL # OF EXITS = 2
EGRESS INFORMATION
HEIGHT
(per IBC 2021
TABLE 504.3 AND
504.4)
HEIGHT IN FEET = 75 FT
HEIGHT IN STORIES = 4 STORIES
ACTUAL BLDG HEIGHT = 3 STORIES
ACTUAL SUITE AREA = 4,295 SFALLOWABLE AREA
(per IBC 2021
TABLE 506.2)
AREA / HEIGHT LIMITATIONS - EXISTING
5.8
F
AA
D2
E3 bb
CC
6 7 7.8 8 8.5 9 10 103 11 104 aa
E
D
C
B
DD
EE
FF
GG
HH
54321 4.8 5.2
18 191716151413
A
BB
103.1 105 105.8 106 106.4 107.8 108108.3108.4 109 110 110.2 110.9 111 113107105.9
232 SF
RECEIVING
61 SF
TLT
112 SF
STORAGE
C O
R R
ID
O
R
C -2
CORRIDOR
C1-208
190 SF
VAULT
107 SF
OFFICE
2251 SF
FILLING/ASSEMBLY
CORRIDOR
C1-103
739 SF
WAITING
ELEVATOR
LOBBY
1B020A
PATH 'A' TRAVEL DISTANCE
189' - 0"
PATH 'B' TRAVEL DISTANCE
221' - 6"
203 SF
LOUNGE
CAPACITYCLR
EXTERIOR
EXIT
72" 360
CAPACITYCLR
EXTERIOR
EXIT
72" 360
AREA OF WORK
CAPACITYCLR
EXTERIOR
EXIT
74" 370
P A
T H
'C ' T
R A
V E
L D
IS
T
A N
C E
9.5 10.2
D.5
264 SF
RECEPTION
104A
239 SF
CHECK-IN
104B
FEC
FEC
OUTPATIENT PHARMACY
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1 /2
:1
:3
A
M C
U s e rs \a p u lle n \D o c u m e n ts
\A V
A M a th e r-
O u tp a ti e n t P h a rm a c y a n d
H V
A C
-C A
-1 a p u lle n V
D X
T .r v t
LS101
FIRST FLOOR LIFE SAFETY PLAN
7 7ANP
RENOVATION OF
OUTPATIENT PHARMACY
AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655 OCTOBER 13, 2023
100% BID DOCUMENTS
612A4-19-01619-103
RMC
PROPOSED USE:
OWNED BY: PRIVATE
FEDERAL GOVERNMENT
CITY/COUNTY
STATE
CODE ENFORCEMENT JURISDICTION: CITY
COUNTY
VA
GENERAL CODE INFORMATION:
RENOVATION (EXISTING BUILDING)
CONSTRUCTION TYPE:
SPRINKLERED
PRIMARY OCCUPANCY:
SECONDARY OCCUPANCY:
PROJECT NAME:
PROJECT ADDRESS:
OWNER OR AGENT:
PHARMACY
IIB
BUSINESS
N/A
RENOVATION OF OUTPATIENT
PHARMACY AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655
VA MATHER
NORTH
0 4 8 16
LIFE SAFETY LEGEND
EGRESS PATH "A"
PATH ID 189' - 0"
EGRESS PATH "B"
PATH ID 221' - 6"
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
Scale: 1/16" = 1'-0"
FIRST FLOOR LIFE SAFETY PLAN
EGRESS PATH "C"
PATH ID 284' - 4"
A. EXISTING 2 HOUR FIRE SEPARATION TO BE
REDUCED TO ONE HOUR FIRE SEPARATION AT
PHARMACY.
B. ONE HOUR FIRE RATED WALL ENCLOSURE WITH
9 GAUGE EXPANDED METAL MESH REQUIRED AT
PHARMACY ENCLOSURE AS PER VA PHYSICAL
SECURITY MANUAL.
CODE INFORMATION
24514
LICENSED
ARCHITECT
American Welding Society
American National Standards Institute
American Society for Testing and Materials
American Iron and Steel Institute
American Institute of Steel Construction
American Institute of Architects
American Concrete Institute
CC Carried Column
CIP Cast In Place
Addition
Alternate
Air Condition
Aggregate
Anchor BoltAB
ALT
A/C
AGGR
ADD
Angle
And
Asphalt
Approximate
AIA
ACI
AISI
ANSI
ASTM
AISC
L
ASPH
ARCH
APPROX
AWS
Average
Bottom
Bearing
Bending Moment
Base Plate
Building
Center
Ceiling
Center to Center
Center of Gravity
Bottom of Deck
M
BOT
BRG
B PL
AVG
CG
CEN
CLG
BLDG
B/D
AssemblyASSY
Architect or Architectural
Column
Clear
Channel
Concrete
Control Joint
Connection
Cubic Yard
Cubic Foot
Continuous
Construction
C
CJ
CONN
CONC
COL
CLR
CY
CF
CMU
CMP
CONT
CONST
Diagonal
Detail
Ditto
Diameter
Double Angle
Dimensions
Drawing
Douglas Fir
2L
DO
DIM
DIA
DIAG
DET
DF
DWG
DoubleDBL
Concrete Masonry Units
Corrugated Metal Pipe
C/C
AluminumAL
MB Machine Bolt
Glu lam BeamGLB
Quarter
Radius
Reference
Reinforce, Reinforced, QTR
REF
RAD
REINF
Round
Required
Section
Schedule
Revise or Revision
South
Similar
Steel
Standard
Square
Specifications
Sheet
Stock
Tangent
Symmetrical
Structural
Strut Force
Through
Top of Concrete
Top and Bottom
Tongue & Groove
Tolerance
Thick
Top of Footing or Top of Foundation
RD
REV
SECT
SCHED
REQD
S
SIM
STL
STD
SQ
SPECS
SHT
SYM
STK
TAN
SF
STRUCT
TOL
T/F
T/C
T & B
T & G
THRU
THK
Typical
Total
Transverse
Top of Steel
Top of Masonry
Vertical
Verify in the Field
Unless Noted
Unless Noted Otherwise
Top of Concrete Wall
West
Without
With
Work Point
Wide Flange
Welded Wire Fabric
Yard
T/S
T/M
TYP
TOT
TRANS
UNO
UN
VIF
VERT
W
W
WWF
WP
W/O
W/
YD
T/W
Reinforcement, or Reinforcing
Long
Light
Length
Laminated
Longitudinal
LAM
LGTH
LG
LT
LONGIT
Each
East
EF
EA
E
EW
ELECT Electric or Electrical
Each way
Each face
Mark
Metal
Maximum
Material
Maximum
Mechanical
Manufacturer
LLH
LLBB
LLV
MK
MAX
MECH
MATL
MAX
MET
MFR
Medium
Mezzanine
Minimum
Minute
Miscellaneous
Mixture
North
Nominal
Near Side
Near Face
Multiple
MED
MIN
MEZZ
MIX
MISC
MIN
NF
N
NOM
NS
MULT
EQ
ENGR
ETC
EST
EXCAV
EQUIP
EXT
EJ
EXIST
X-STR
X-HVY
Etcetera
Extra Strong
Extra Heavy
Exterior
Expansion Joint
Existing
Excavate
Estimate
Equipment
Equal
Engineer
FS
FF
FT or '
FIN
FIG
FBM
FTG
FD
FRMG
FND
FLR
Framing
Foundation
Footing
Floor Drain
Floor
Finish
Figure
Feet Board Measure
Feet or Foot
Far Side
Far Face
FabricationFAB
Opposite
Opening
On Center
Number
Perpendicular
Permanent
Original
OPP
OPNG
OC
OD
PERP
PERM
d
ORIG
Point
Plate
Pound
Plywood
Project
PT
PL
PLYWD
PSF
PCF
LB
PROJ
PSI
Piece, Pile CapPC
GEN
GI
GALV
GRND
GR
HEX
HGT
HORIZ
S
IN or " Inches
I Beam
Horizontal
Hexagon
Height
Ground
Grade
General (Notes)
Galvanized Iron
Galvanize
Joint
Joist
ID
JT
JST
KO
K
Knockout
Kip (1,000 lbs)
Inside Diameter
Include or IncludedINCL
Not to ScaleGage or Gauge NTSGA
Elevation LHEELEV
Pounds Per Square Inch
Pounds Per Square Foot
Pounds Per Cubic Foot
Penny (Nails, etc)
Outside Diameter
Long Leg Vertical
Long Leg Horizontal
Long Leg Back To Back
Low Hydrogen Electrode
General Structural NotesGSN
LEGEND:
GSN = GENERAL STRUCTURAL NOTES
UNO = UNLESS NOTED OTHERWISE
INDICATES TUBE COLUMN
INDICATES WIDE FLANGE COLUMN
INDICATES BEAM SPLICE
INDICATES FOOTING SIZE. SEE SCHEDULE.
F1
SYMBOLS AND ABBREVIATIONS FOR CONCRETE (as per ACI)
SLOPE DIRECTION DOWN
MISCELLANEOUS ELEVATION
FLOOR OR STEEL ELEVATION
REQUIRED NUMBER OF HEADED SHEAR STUDS
RIGID CONNECTION
CAMBER UP
00'-0"
00'-0"
(00'-0")
C=0"
[00]
STEEL ELEVATION
SPAN DIRECTION
To Indicate Size of Deformed Bar.#
Clear
Bottom
Bent
Each Face
Column Tie
Each Way
Limits of Area Covered By Bars
Direction in Which Bars Extend
Spacing Center to Center
Spiral
Stirrup
Plain Bar
Outside Face
Near Face
Inside Face
Top
Straight
Far Face
AT
EF
CT
CL
BOT
BT
EW
T
STR
SP
STIR
PL
OF
NF
IF
FF
Plain Rounds, as Spirals/
INDICATES STD PIPE COLUMN
Construction Management Civil Engineering Surveying
9090 South Ridgeline Boulevard, Suite 105
Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com
Calibre Engineering, Inc.
Calib er
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/9 /2
:3
:4
P
M C
U s e rs \t b e n ja m in
\D o c u m e n ts \M a th e r_
V A
M C
P h a rm a c y V a u lt
S T
R U
C T tb e n ja m in
C Q
U N
D .r v t
S-001
ABBREVIATIONS, SYMBOL LEGEND,
AND GENERAL STRUCTURAL NOTES
1 6MBT
RENOVATION OF
OUTPATIENT PHARMACY
AND HVAC
MATHER VAMC
10535 HOSPITAL WAY
MATHER, CA 95655 OCTOBER 13, 2023
100% BID DOCUMENTS
612A4-19-01619-103
GMG
SYMBOL LEGEND
ABBREVIATIONSGENERAL STRUCTURAL NOTES
CODE AND DESIGN CRITERIA
1. BUILDING CODE: LATEST EDITION OF U.S. DEPARTMENT OF VETERANS AFFARIS
DESIGN GUIDES, STANDARDS, AND MANUALS. 2018 INTERNATIONAL BUILDING
CODE (IBC)
2. DESIGN LIVE LOADS:
A. ROOF LL: 20 PSF
3. WIND DESIGN DATA:
A. BASIC WIND SPEED: 104 MPH (ULTIMATE)
B. EXPOSURE: C
C. INTERNAL PRESSURE COEFFICIENT: ±0.18
4. SEISMIC DESIGN DATA
A. BUILDING RISK CATEGORY: IV
B. IMPORTANCE FACTOR: 1.5
C. SS: 0.460g D. S1: 0.225g
E. SITE CLASS: C
F. SDS: 0.439g G. SD1: 0.293g
H. SEISMIC DESIGN CATEGORY: D
I. SFRS:
a. SPECIAL REINFORCED MASONRY SHEAR WALLS
b. RESPONSE MODIFICATION FACTOR (R): 5
c. SEISMIC RESPONSE COEFFICIENT (CS): 0.132
GENERAL
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION. NOTIFY COR OF ANY
DISCREPANCIES
2. DO NOT SCALE THE DRAWINGS.
3. GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS APPLY UNLESS NOTED OTHERWISE ON PLANS, ELEVATIONS, DETAILS AND SPECIFICATIONS. IN CASE OF CONFLICT THE GREATER REQUIREMENT GOVERNS.
4. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO
NOT INDICATE THE METHOD OF CONSTRUCTION.
5. THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, FOR THE ACTS OF OMISSIONS OF THE CONTRACTOR, SUB- CONTRACTORS OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY OF THEM
TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
6. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING AND SHORING FOR LOADS DUE TO HYDROSTATIC, EARTH, WIND OR SEISMIC FORCES, CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS.
7. NOTIFY THE STRUCTURAL ENGINEER THROUGH THE COR WHEN DRAWINGS BY OTHERS SHOW OPENINGS, POCKETS, ETC., NOT SHOWN ON THE STRUCTURAL DRAWINGS, BUT WHICH ARE LOCATED IN THE STRUCTURAL MEMBER.
8. ALL SPECIFICATIONS AND CODES NOTED SHALL BE THE LATEST APPROVED EDITIONS AND REVISIONS BY THE
GOVERNMENTAL AGENCY HAVING JURISDICTION OVER THIS PROJECT.
9. COST OF ADDITIONAL FIELD AND OFFICE WORK NECESSITATED BY REQUESTS BY THE CONTRACTOR FOR AN OPTION OR DUE TO ERRORS OR OMISSIONS IN CONSTRUCTION SHALL BE BORNE BY THE CONTRACTOR. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. HE SHALL BE RESPONSIBLE FOR ALL CHANGES NECESSARY IF HE CHOOSES AN
OPTION AND HE SHALL COORDINATE ALL DETAILS.
10. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN
ENGINEER REGISTERED IN CALIFORNIA.
11. UNLESS NOTED OTHERWISE, DETAILS ON STRUCTURAL DRAWINGS ARE TYPICAL AS INDICATED BY CUTS, REFERENCES OR TITLE.
12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
13. FIELD VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO THE START OF SHOP DRAWINGS OR
CONSTRUCTION.
14. EXISTING CONDITIONS REQUIRING MODIFICATIONS TO DOCUMENTS FOR PROPOSED CONSTRUCTION SHALL BE
IMMEDIATELY SUBMITTED TO THE COR.
FOUNDATION
1. FOUNDATION:
A. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL REPORT #3746.04 PREPARED BY WALLACE KUHL ASSOC.
DATED 06/09/1999
B. FOOTING SHALL BEAR ON FIRM UNDISTURBED SOIL AT 12" MIN BELOW FINISH GRADE OR NATURAL GRADE, WHICHEVER IS LOWER. ALLOWABLE BEARING = DL 1500 PSF, DL + LL 2300 PSF, DL + LL + SEISMIC.
2. SEE PLAN FOR TOP OF FOOTING ELEVATIONS. CONTRACTOR SHALL VERIFY AND LOWER FOOTINGS AS REQUIRED TO
MAINTAIN 1' - 6” MINIMUM BELOW FINISH GRADE OR FINISH FLOOR (THE LOWER) AT FOOTINGS.
3. CONTRACTOR SHALL PROVIDE FOR PROPER DEWATERING OF EXCAVATIONS FROM SURFACE WATER, GROUND
WATER, SEEPAGE, ETC.
4. CONTRACTOR SHALL PROVIDE FOR THE DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING AND SHORING
REQUIRED TO SAFELY AND ADEQUATELY RETAIN THE EARTH BANKS AND ANY EXISTING STRUCTURE.
5. ALL EARTHWORK, FOOTING DEPTHS, AND EXCAVATIONS FOR FOUNDATIONS SHALL BE INSPECTED BY THE
GEOTECHNICAL ENGINEER TO VERIFY ASSUMED ALLOWABLE SOIL BEARING PRESSURE AND TO MAKE ANY
ADDITIONAL RECOMMENDATIONS.
6. EXCAVATIONS FOR FOOTINGS SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACING THE REINFORCING AND CONCRETE. THE CONTRACTOR SHALL NOTIFY THE GEOTECHNICAL ENGINEER WHEN THE EXCAVATIONS ARE READY FOR INSPECTION. THE GEOTECHNICAL ENGINEER SHALL SUBMIT A LETTER OF COMPLIANCE
TO THE COR.
7. ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED. DO NOT PLACE BACKFILL BEHIND RETAINING WALLS BEFORE CONCRETE OR MASONRY HAS ATTAINED FULL DESIGN STRENGTH. CONTRACTOR SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHING FLOORS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL DESIGN STRENGTH. CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMITS AND
INSTALLATION OF SUCH BRACING AND PROTECTION.
8. FOOTING BACKFILL AND UTILITY TRENCH BACKFILL WITHIN THE BUILDING PERIMETER SHALL BE MECHANICALLY COMPACTED IN LAYERS, TO THE APPROVAL OF THE GEOTECHNICAL ENGINEER. FLOODING WILL NOT BE PERMITTED.
9. ALL ABANDONED FOOTINGS, UTILITIES, ETC., THAT INTERFERE WITH THE NEW CONSTRUCTION SHALL BE REMOVED
REINFORCING STEEL
1. ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN CONFORMANCE WITH THE `BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE' (ACI 318) AND THE `MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION' BY CRSI AND WCRSI, AS MODIFIED BY THE PROJECT DRAWINGS AND
SPECIFICATIONS.
2. DEFORMED REINFORCING BARS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615 GRADE 60.
3. WELDING OF REINFORCING SHALL BE WITH LOW HYDROGEN ELECTRODES IN CONFORMANCE WITH 'RECOMMENDED
PRACTICES FOR WELDING REINFORCING STEEL, ETC.', AMERICAN WELDING SOCIETY, AWS D1.4. WELDING OF
REINFORCING STEEL IS LIMITED TO A706 REBAR.
4. ALL REINFORCING BAR BENDS SHALL BE MADE COLD.
5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064.
6. MINIMUM LAP OF WELDED WIRE FABRIC SHALL BE 6 INCHES OR ONE FULL MESH AND ONE HALF, WHICH EVER IS
GREATER.
7. SPLICES SHALL BE MADE ONLY AS AND WHERE INDICATED ON THE STRUCTURAL DRAWINGS.
8. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE, SPACING AND NUMBER
AS THE SPECIFIED VERTICAL REINFORCING, U.N.O.
9. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN THE FINAL IN-PLACE INSPECTION
OCCURS.
10. PROVIDE SHOP DRAWINGS AND FABRICATE AFTER THE COR'S REVIEW. ALL SPLICE LOCATIONS ARE SUBJECT TO
APPROVAL. PLACE REBAR PER CRSI STANDARDS.
CONCRETE
1. ALL PHASES OF WORK PERTAINING TO THE CONCRETE CONSTRUCTION SHALL CONFORM TO THE 'BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE', ACI 318, AND THE `SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS', ACI 301, LATEST EDITIONS, WITH MODIFICATIONS AS
NOTED ON THE DESIGN DRAWINGS OR SPECIFICATIONS.
2. REINFORCED CONCRETE DESIGN IS BY THE ULTIMATE STRENGTH DESIGN METHOD.
3. CONCRETE MIXES SHALL BE DESIGNED BY A QUALIFIED TESTING LABORATORY AND SHALL BEAR THE
SEAL OF A CIVIL ENGINEER LICENSED IN THE STATE OF CALIFORNIA.
4. SCHEDULE OF STRUCTURAL CONCRETE 28-DAY STRENGTHS AND TYPES:
5. PORTLAND CEMENT SLAL CONFORM TO ASTM C150, TYPE II.
6. AGGREGATE FOR HARD ROCK CONCRETE SHALL CONFORM TO ALL REQUIREMENTS AND TESTS OF
ASTM C33 AND PROJECT SPECIFICATIONS. EXCEPTIONS MAY BE USED ONLY WITH PERMISSION OF
THE STRUCTURAL ENGINEER THROUGH THE COR.
7. CONCRETE MIXING OPERATIONS, ETC., SHALL CONFORM TO ASTM C94.
8. PLACEMENT OF CONCRETE SHALL CONFORM TO ACI STANDARD 304 AND PROJECT SPECIFICATIONS.
SANDBLAST ALL CONCRETE SURFACES AGAINST WHICH CONCRETE IS TO BE PLACED.
9. PLACING OF CONCRETE SHALL CONFORM TO ACI 305 "HOT WEATHER CONCRETING" AND ACI 306
"COLD WEATHER CONCRETE" WHEN APPLICABLE.
10. CLEAR COVERAGE OF CONCRETE OVER REINFORCING BARS BE AS FOLLOWS:
A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3”
B. CONCRETE EXPOSED TO EARTH OR WEATHER:
1. NO. 6 THROUGH NO. 18 BAR: 2”
2. NO. 5 BAR AND SMALLER: 1 1/2”
C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND
1. SLABS, WALLS, JOISTS:
A. NO. 14 AND NO. 18 BAR: 1 1/2”
B. NO. 11 BAR AND SMALLER: 3/4
2. BEAMS, COLUMNS:
1. PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS: 1 1/2”
D. SLABS ON GRADE (FROM TOP): 1 1/2”
11. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE…