This document package includes mechanical drawings and specifications for the replacement of Pier 3 at Naval Station Norfolk in Virginia. The project involves upgrading the mechanical systems at the Utility Services Building including new HVAC equipment, ductwork, piping, controls and associated components. Detailed drawings show proposed equipment layouts, schedules list specifications for new fans, pumps, air handlers, louvers, unit heaters and other devices. The specifications include notes, details, diagrams and schedules providing requirements for installing and integrating the new mechanical systems. The federal solicitation seeks bids from contractors to complete the Pier 3 recapitalization project in accordance with the specifications in this mechanical design package.

View the file

Other files

File Type Posted
Amendment 0010 and 0011.pdf PDF
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
MIL-STD-767 REV G.pdf PDF
Amendment 0007.pdf PDF
1614696Amend0006dwg 1of1.pdf PDF
Attachment K- PIEE Vendor Access Instructions.pdf PDF
1614696Amend0006spc 1of1.pdf PDF
Amendment 0006.pdf PDF
Pier 3 Contractor Laydown Map.pdf PDF
Attachment H - Price Proposal Form Revised 3.docx DOCX document
Amendment 0005.pdf PDF
Attachment G - Small Business Subcontracting Plan Template Revised.pdf PDF
Amendment 0004.pdf PDF
1614696Amend0004dwg 1of1.pdf PDF
Composite Camel Reference Drawings.pdf PDF
Attachment C - Construction and Design Experience Project Data Sheet.docx DOCX document
Attachment H - Price Proposal Form Revised 2.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
P095 Site Visit Log.pdf PDF
Attachment H-Price Proposal Form Revised.docx DOCX document
Amendment 0001.pdf PDF
1614696dwg15of22_ARCH-BUILD.pdf PDF
Attachment E - Historical SB Utilization.docx DOCX document
1614696spc05of19_APP-A4.pdf PDF
1614696Amend0001dwg 2of4.pdf PDF
1614696dwg11of22_STRUCT-PIER.pdf PDF
1614696spc11of19_APP-B3.pdf PDF
1614696dwg20of22_ELEC-BUILD.pdf PDF
1614696spc10of19_APP-B2.pdf PDF
1614696spc17of19_APP-E.pdf PDF
Attachment A - PPI Log.doc DOC document
1614696dwg04of22_GEOTECH.pdf PDF
Attachment G - Small Business Subcontracting Plan Template.doc DOC document
1614696dwg13of22_MECH-PIER.pdf PDF
1614696dwg06of22_CIVIL-SITE.pdf PDF
1614696spc16of19_APP-D.pdf PDF
Attachment D - Past Performance Questionnaire.docx DOCX document
1614696spc02of19_APP-A1.pdf PDF
Attachment I - ODP Badge Access Request.xls XLS spreadsheet
1614696dwg22of22_CAT_PROTECT.pdf PDF
1614696spc15of19_APP-C.pdf PDF
1614696dwg14of22_ELEC-PIER.pdf PDF
1614696Amend0001dwg 4of4.pdf PDF
1614696dwg10of22_STRUCT-PIER.pdf PDF
1614696spc06of19_APP-A5.pdf PDF
1614696spc01of19.pdf PDF
Attachment B - SECNAV 5512.pdf PDF
1614696dwg12of22_FIRE-PIER.pdf PDF
Show 40 more

Latest 50 of 79 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. THESE GENERAL NOTES APPLY TO ALL MECHANICAL DRAWINGS IN THIS SET.

SHEET SPECIFIC NOTES ARE INDICATED ON EACH SHEET UNDER GENERAL

SHEET NOTES.

2. PATCH ALL HOLES FROM REMOVAL OF PIPING, DUCTWORK, OR EQUIPMENT TO

MATCH ADJACENT CONSTRUCTION.

3. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM LABOR REQUIRED TO

INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON

THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE.

4. INSTALL ALL MECHANICAL EQUIPMENT AN APPURTENANCES IN ACCORDANCE

WITH MANUFACTURER'S RECOMMENDATIONS, CONTRACT DOCUMENTS, AND

APPLICABLE CODES AND REGULATIONS.

5. PROVIDE VIBRATION ISOLATORS AS INDICATED ON THE DRAWINGS FOR

MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION OF VIBRATION TO

BUILDING STRUCTURE.

6. PROVIDE ACCESS PANELS IN WALLS AND CEILINGS, WHERE REQUIRED, TO

SERVE FIRE DAMPERS, VALVES, SMOKE DETECTORS, AND OTHER CONCEALED

MECHANICAL EQUIPMENT THAT REQUIRES ROUTINE MAINTENANCE. ACCESS

PANELS MUST BE LARGE ENOUGH TO ALLOW PROPER CLEARANCE FOR

ACCESS DOORS. SEE ARCHITECTURAL PLANS FOR LOCATIONS. COORDINATE

PANELS WITH FINAL LOCATION OF MECHANICAL EQUIPMENT, DUCTWORK,

PIPING, VALVES, ETC.

7. PROVIDE FIRESTOP FOR ALL OPENINGS IN FIRE WALLS DUE TO DUCTWORK,

PIPING, CONDUIT, ETC.

8. EXISTING DUCT AND PIPING SIZES INDICATED ARE APPROXIMATE. FIELD VERIFY

ALL DIMENSIONS.

9. LOCATE ALL NEW HORIZONTAL DUCTWORK ABOVE THE SUSPENDED CEILINGS

UNLESS OTHERWISE INDICATED.

10. ALL 90 DEGREE RECTANGULAR MITERED DUCT ELBOWS IN THE SUPPLY,

EXHAUST, OUTSIDE, AND RETURN DUCT MUST HAVE TURNING VANES.

11. PROVIDE PIPE SLEEVES FOR ALL PIPING PENETRATIONS THRU WALLS AND

FLOORS. EACH PIPE MUST BE SEPARATELY SLEEVED. PROVIDE CONTINUOUS

SEALANT JOINT AROUND PIPE SLEEVE, BOTH SIDES OF WALL, WATERTIGHT.

12. PROVIDE P-TRAPS IN CONDENSATE DRAIN PIPING AT EACH COOLING COIL

UNLESS THE COOLING COIL IS EQUIPPED WITH AN INTERNAL TRAP.

13. AFTER THE PIPING IS INSULATED, PROVIDE FACTORY-FABRICATED PIPE

LABELS, WITH DIRECTION OF FLOW ARROWS, ON THE FOLLOWING PIPING, AT

10 FOOT ON CENTER ON THE PIPING MAINS AND 5 FOOT ON CENTER ON THE

BRANCH RUNOUTS FROM THE MAINS.

14. DUCT RUNOUT SIZE TO DIFFUSER, REGISTER, OR GRILLE MUST BE SAME AS

NECK SIZE.

15. MOUNT THERMOSTATS, HUMIDISTATS, AND ESS 48 INCHES ABOVE FINISHED

FLOOR UNLESS OTHERWISE INDICATED. REFER TO ELECTRICAL DRAWINGS

FOR LOCATION OF LIGHT SWITCHES.

16. SLOPE CONDENSATE PIPING 1/8 INCH PER FOOT DOWNWARD IN THE DIRECTION

OF FLOW. PROVIDE CLEANOUTS AT EACH CHANGE IN DIRECTION GREATER

THAN 45 DEGREES OR ONCE EVERY 45 FEET OF LINEAR PIPE LENGTH.

COMBINATION WYE AND 1/8 BENDS MUST BE USED IN LIEU OF TEES.

17. INSTALL LOUVER PLENUMS WITH MINIMUM 1/4 INCH PER FOOT SLOPE

DOWNWARDS TOWARDS EXTERIOR FOR DRAINAGE.

18. SEAL ALL UNUSED PORTIONS OF LOUVERS WITH INSULATED METAL BLANK-OFF

PANELS.

19. MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL

OFFSETS, FITTINGS, AND CONNECTIONS NECESSARY FOR COMPLETE

INSTALLATION. PROVIDE ANY AND ALL ADDITIONAL OFFSETS, FITTINGS, AND

CONNECTIONS REQUIRED FOR COMPLETE AND OPERABLE SYSTEM. OFFSETS

MUST BE THE MINIMUM POSSIBLE TO MAKE THE CONNECTIONS.

20. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH ALL OTHER

TRADES PRIOR TO BEGINNING INSTALLATION.

21. INSTALLATION MUST ALLOW FOR SYSTEM MAINTENANCE TO OCCUR.

PROVIDED MANUFACTURER'S RECOMMENDED CLEARANCES.

22. ALL PIPE HANGERS MUST BE SECURED TO THE STRUCTURE OR CONTRACTOR

PROVIDED SUPPORTS BETWEEN THE STRUCTURE. PIPE HANGERS MUST NOT

BE HUNG FROM THE ROOF DECK.

GENERAL MECHANICAL NOTES

° DEGREES

Ø DIAMETER

ADJ ADJUSTABLE

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AI ANALOG INPUT

AS AIR SEPARATOR

AUX AUXILIARY

BD BALANCING DAMPER

BDD BACKDRAFT DAMPER

BHP BRAKE HORSEPOWER

CCC CLOSED CIRCUIT COOLER

CD CEILING DIFFUSER

CV LOSS COEFFICIENT

CFM CUBIC FEET PER MINUTE

CU CONDENSING UNIT

DB DRY BULB

DDC DIRECT DIGITAL CONTROL

DEG DEGREE

DN DOWN

DSS DUCTLESS SPLIT SYSTEM

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EER ENERGY EFFICIENCY RATIO

EF EXHAUST FAN

EG EXHAUST GRILLE

EP EXHAUST PIPE (GENERATOR)

ESP EXTERNAL STATIC PRESSURE

EWT ENTERING WATER TEMPERATURE

F FAHRENHEIT

FC FAN COIL

FLA FULL LOAD AMPERAGE

FT FEET

GI GRAVITY INTAKE

GPM GALLONS PER MINUTE

GR GRAVITY RELIEF

HP HEAT PUMP, HORSEPOWER

HPAC HIGH PRESSURE AIR COMPRESSOR

HR HOUR

HZ HERTZ

IAW IN ACCORDANCE WITH

IN WC INCHES WATER COLUMN

KW KILOWATT

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

L LENGTH

LS LINEAR SLOT

LWT LEAVING WATER TEMPERATURE

MAX MAXIMUM

MBH THOUSANDS OF BTU/HOUR

MCA MINIMUM CIRCUIT AMPACITY

MD MOTORIZED DAMPER

MIN MINIMUM

MINS MINUTES

MOCP MAXIMUM OVERCURRENT PROTECTION

MPAC MEDIUM PRESSURE AIR COMPRESSOR

NC NORMALLY CLOSED, NOISE CRITERIA

NO NORMALLY OPEN

OA OUTSIDE AIR

OD OUTSIDE DIAMETER

PH PHASE

PSI POUNDS PER SQUARE INCH

RA RETURN AIR

RG RETURN GRILLE

RH RELATIVE HUMIDITY

RL REFRIGERANT LIQUID

RR RETURN REGISTER

RS REFRIGERANT SUCTIONSA SUPPLY AIR

SEER SEASONAL ENERGY EFFICIENCY RATIO

SG SUPPLY GRILLE

SP STATIC PRESSURE

SQ SQUARE

SS SPLIT SYSTEM

TYP TYPICAL

UH UNIT HEATER

USB UTILITY SERVICES BUILDING

VLV VALVE

V VOLTS

VFD VARIABLE FREQUENCY DRIVE

W WIDTH

WB WET BULB

SEE SHEET AM-701 FOR ADDITIONAL CONTROL ABBREVIATIONS.

MECHANICAL ABBREVIATIONSMECHANICAL LEGEND

T THERMOSTAT

ROUND DUCT DIMENSION

RECTANGULAR DUCT DIMENSIONS (INCHES)12x10

12"Ø

SUPPLY DUCT DOWN/UP

RETURN DUCT DOWN/UP

BUTTERFLY VALVE

PRESSURE REDUCING VALVE

DRAIN VALVE WITH HOSE CONNECTION

2-WAY CONTROL VALVE

3-WAY CONTROL VALVE

RELIEF VALVE

MANUAL AIR VENT

AUTOMATIC AIR VENT

WYE STRAINER

CLEAN OUT

UNION

PRESSURE GAUGE WITH SHUTOFF COCK

THERMOMETER

PIPE CAP

FLANGE

FLEXIBLE PIPE CONNECTOR

C.O.

EXHAUST DUCT DOWN/UP

M

M

MV

MANUAL CALIBRATED BALANCING VALVE

MOTORIZED DAMPER

MD

S TEMPERATURE SENSOR

BALL VALVE

SUPPLY CEILING DIFFUSER

RETURN CEILING DIFFUSER

EXHAUST CEILING DIFFUSER

SUPPLY CEILING DIFFUSER

SUPPLY GRILLE

RETURN/EXHAUST GRILLE

RADIUS ELBOW

MITERED ELBOW WITH TURNING VANES

PIPING TO BE REMOVED

MECHANICAL PIPING LEGEND

CONDENSER WATER RETURN PIPING

COMPRESSED AIR PIPING

CONDENSER WATER SUPPLY PIPING

CONDENSATE DRAIN PIPING

DOMESTIC COLD WATER PIPING

HEATING HOT WATER SUPPLY PIPING

HEATING HOT WATER RETURN PIPING

REFRIGERANT LIQUID PIPING

REFRIGERANT SUCTION PIPING

(NAME)

CA

CWR

CWS

CD

DCW

HHWR

HHWS

RL

RS

DOMESTIC HOT WATER PIPINGDHW

MEDIUM PRESSURE COMPRESSED AIR PIPINGMPCA

HIGH PRESSURE COMPRESSED AIR PIPINGHPCA

ROOM TAG

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL TAG

ROOM NAME

ROOM NUMBER

DETAIL NUMBER

SCALE

SHEET

REFERENCED

FROM

SECTION TAG

SECTION NUMBER

SHEET WHERE DRAWN

GENERAL PROJECT SYMBOLS

NEW WORK

KEYNOTE TAG

KEYNOTE NUMBER

DEMO

KEYNOTE TAG

KEYNOTE NUMBER

? PHOTOGRAPH TAG

PHOTOGRAPH NUMBER

SHEET WHERE SHOWN

PLAN

NORTH

SCALE

TRUE NORTH

SHEET

REFERENCED

FROM

AIR DISTRIBUTION DEVICE

IDENTIFICATION

EQUIPMENT

IDENTIFICATION

VAV - XX

EQUIPMENT

TYPE

EQUIPMENT

NUMBER

175 CFM

CD-# #x#

NECK

SIZE

(IN)

MARK

AIR FLOW

36.93 N

LONGITUDE:

ELEVATION:

LATITUDE:

SUMMER DESIGN WET BULB (0.4%):

SUMMER DESIGN DRY BULB (0.4%):

WINTER DESIGN DRY BULB (99.6%):

STANDARD OUTDOOR DESIGN CONDITIONS:

21°F

78°F 94°F

76.28 W

16 FT.

HVAC DESIGN CRITERIA

LOCATION: NAVAL STATION NORFOLK, VA

STATION ID# ICAO_KNGU

SUMMER

DESIGN DRY

BULB:

WINTER

DESIGN DRY

BULB:

STANDARD INDOOR DESIGN CONDITIONS:

78°F 50% RH 68°F NC*

SUMMER

DESIGN

HUMIDITY:

GUARD BOOTH

ROOM TYPE:

*UC - UNCONTROLLED

*NC - HUMIDITY NOT DIRECTLY CONTROLLED

WINTER

DESIGN

HUMIDITY:

CLIMATE ZONE 3A

CONDENSING UNIT (0.4% DB + 5°F): 99°F

1% HR/MCWB WET BULB

1% HR/MCWB DRY BULB

77.8°F 82.9°F

57.9°F

SUMMER

DESIGN

DEW POINT:

78°F 50% RH 68°F NC*GATEHOUSE 57.9°F

78°F 50% RH 68°F NC*ROOM USB8 TELECOM ROOM

& ROOM USB9 FIRE ALARM

CLOSET

57.9°F

UTILITY SERVICE BUILDING

UC UC 55°F NC*ALL OTHER UNOCCUPIED SPACES UC

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

L K

N

O R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:2

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM001

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

LE

G

E N

D , A

B R

E V

IA

T

IO

N

S , A

N D

N O

TE

S

CMG

12829422

DKH DKH

1614696

UP

1 2 3 4

A

B

C

D

AM101

A1

AM102

A1

M A

T C

H L

IN

E

S E

E T

H

IS

S H

E E

T F

O R

C O

N T

IN

U

A T

IO

N

PURE WATER

ROOM

USB3

FIRE PUMP

USB1

FRESH WATER

PUMP ROOM

USB2

EQUIPMENT

YARD

USB0

MEDIUM

PRESSURE AIR

ROOM

USB4

MECHANICAL

PIPE PIT

4 5 76

A

B

C

D

AM103

A1

AM104

A1

M A

T C

H L

IN

E

S E

E T

H

IS

S H

E E

T F

O R

C O

N T

IN

U

A T

IO

N

HIGH PRESSURE

AIR ROOM

USB5

MAIN

ELECTRICAL

ROOM

USB6

TELECOM ROOM

USB8

GENERATOR

ROOM

USB7

FIRE ALARM

CLOSET

USB9

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

2. LOCATE ALL THERMOSTAT AND TEMPERATURE SENSORS 5'-0" AFF.

GENERAL NOTES

UTILITY SERVICES

BUILDING (USB)

GATEHOUSE

GUARD BOOTH

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:5

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM100

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

M E

C H

A N

IC

A

L O

V E

R A

LL

F

LO

O

R P

LA

N

CMG

12829423

BRF BRF

1614696

4' 8' 16'0'

PLAN

NORTH

1/8" = 1'-0" C1

MECHANICAL PLAN OVERALL - WEST

1/8" = 1'-0" A1

MECHANICAL PLAN OVERALL - EAST

4' 8' 16'0'

PLAN

NORTH

KEY PLAN

PLAN

NORTH

FC-1

FC-2

1 2 3

A

B

C

D

P-3

P-4

4"ø CWS

4"ø CWR

C1

AM301

L-10 40x32

2160 CFM

L-2 32x24

2160 CFM

M A

T C

H L

IN

E

S E

E A

M

F

O R

C O

N T

PURE WATER

ROOM

USB3

FIRE PUMP

USB1

FRESH WATER

PUMP ROOM

USB2

EQUIPMENT

YARD

USB0

L-1 24x32

1100 CFM

EF-2

EF-1

32x24 EA

24x32 EA

20x20 EA

20x20 EA

PROVIDE 28" X 28"

EA OPENING

14x14 SA

16x16 RA

PROVIDE 22" X 22"

SA OPENINGS

PROVIDE 24" X 24"

RA OPENING

10x10 RA

RG-1 10x10

210 CFM

10x10 RA

12x12 RA

RG-1 10x10

210 CFM

14x8 SA

10x14 EA

14x14 EAPROVIDE 14" X 14"

EA OPENING -

550 CFM

SG-1 12x6

210 CFM

12x6 SA

12x6 SA

SG-1 12x6

210 CFM

16x14 RA

3/4"ø HHWR

3/4"ø HHWS 3/4"ø HHWR

3/4"ø HHWS

CCC-1 CCC-2

27 27

T

EF-1

T EF-2

VLV-12

VLV-13

14x14 EA

10x10 EA

EG-1 10x10

550 CFM 65

(TYP)

BDD

40x32 OA

50 (TYP)

L-9 24x16

550 CFM

24x16 OA

L-8 24x16

550 CFM

24x16 OA

T

T

T

FC-1

FC-1

SHUT OFF VALVE

(TYP)

56 (TYP)

63 (TYP)

(TYP)

(TYP.)

BDD

T

FC-2

4"ø CWS

4"ø CWR

4"ø CWS 4"ø CWR

VLV-1 VLV-2

VLV-3

NITROGEN STORAGE TANKS

SEE SHEET AP111

(TYP.)

(TYP)

(TYP)

MD-1 MD-2

MD-3

(TYP.)

EF-1

(TYP.)

(TYP.)

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

2. LOCATE ALL THERMOSTAT AND TEMPERATURE SENSORS 5'-0" AFF.

GENERAL NOTES

WORK NOTES

KEYPLAN

UTILITY SERVICES

BUILDING (USB)

GATEHOUSE

GUARD BOOTH

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:0

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM101

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

M E

C H

A N

IC

A

L E

N

LA

R G

E D

F

LO

O R

P

LA

N

S H

E E

T

O F

CMG

12829424

BRF BRF

1614696

1/4" = 1'-0" A1

MECHANICAL FLOOR PLAN - HVAC - AREA A

26 SEE FAN COIL UNIT PIPING DETAIL C4/AM501.

27 SEE USB CONDENSER WATER PIPING DIAGRAM SHEET AM610.

38 PROVIDE 16 GAGE, 2x2 MESH, GALVANIZED HARDWARE CLOTH OVER

OPENING.

45 DDC CONTROL PANEL 120 VOLTS 1 PHASE.

50 SEE PIPE PENETRATION DETAIL C3/AP504.

51 SEE DRAIN VALVE CONNECTION DETAIL C4/AM502.

56 SEE RECTANGULAR BRANCH DUCT TAKE-OFF DETAIL A3/AM503.

59 SEE LOW VELOCITY DUCT LAYOUT C3/AM503.

60 SEE HYDROSTATIC SEAL DETAIL A1/AM504.

61 SEE DIFFUSER, GRILLE & REGISTER CONNECTION DETAIL A4/AM504.

63 SEE RECTANGULAR FLEXIBLE CONNECTION DETAIL A2/AM505.

65 SEE CABINET OR INLINE EXHAUST FAN DETAIL C1/AM505.

75 SEE PIPE SUPPORT DETAILS A1/AM502.

76 LOCATE MECHANICAL PIPING AS INDICATED. COORDINATE WITH OTHER

TRADES WITH GRAVITY DRAINS AND DUCTWORK TAKING PRECEDENCE.

MINIMUM PIPE HEIGHT MUST BE 8'-0" AFF. SUSPEND ALL PIPING FROM

STRUCTURAL STEEL. PIPING MUST NOT BE SUPPORTED FROM THE

ROOF DECK.

2' 4' 8'0'

PLAN

NORTH

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

2. LOCATE ALL THERMOSTAT AND TEMPERATURE SENSORS 5'-0" AFF.

GENERAL NOTESWORK NOTES

FC-3

3 4

A

B

C

D

P-1 P-2

ET-1

P-5

A4

AM301

4"ø CWS

4"ø CWS

3"ø CWR

4"ø CWR

A1

AM301

L-3 48x48

6080 CFM

L-11B 72x48

4675 CFM

M A

T C

H L

IN

E

S E

E A

M

F

O R

C O

N T

M A

T C

H L

IN

E

S E

E A

M

F

O R

C O

N T

MPAC-1 MPAC-2 MPAC-3 MPAC-4

3"ø CWR

2 1/2"ø CWR 2 1/2"ø CWR 2 1/2"ø CWR 2 1/2"ø CWR

EF-3

48x48 EA

28x28 EA

28x28 EA

PROVIDE 36" X 36"

EA OPENING

14x14 SA

PROVIDE 14" X14"

SA OPENINGS

PROVIDE 24" X 24"

RA OPENING

3/4"ø HHWR

25 25 25 25

GFS-1

2 1/2"ø CWS

2 1/2"ø CWS

2 1/2"ø CWS 2 1/2"ø CWS

VLV-4 VLV-5 VLV-6

VLV-7

AS-1

T

EF-3

PIPE ANCHOR

(TYP)

MEDIUM

PRESSURE AIR

ROOM

USB4

V-14

30x30 EA

UP TO GR-1

20x12 EA20x12 EA

30x30 EA

UP TO GR-2

30x30 EA

UP TO GR-3

30x30 EA

UP TO GR-4

20x12 EA BELOW

L-11A 72x48

4675 CFM

L-11C 72x48

4675 CFM

38 72x48 OA

(TYP)

50 (TYP)

3/4" Ø DCW SEE

PLUMBING FLOOR

PLAN - AREA B

SHEET AP102 FOR

CONTINUATION

72x48 OA

72x48 OA

16x16 RA

(TYP.)

(TYP.)

BDD

(TYP.)

T

FC-3

(TYP)

MD-4 MD-5

MD-6

MD-12

MD-13

MD-14

MD-15

MD-16

MD-17 MD-18

MD-19

3/4"ø HHWS

MECHANICAL

PIPE PIT

UH-3

T

UH-3

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

KEYPLAN

UTILITY SERVICES

BUILDING (USB)

GATEHOUSE

GUARD BOOTH

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:0

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM102

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

M E

C H

A N

IC

A

L E

N

LA

R G

E D

F

LO

O R

P

LA

N

S H

E E

T

O F

CMG

12829425

BRF BRF

1614696

1/4" = 1'-0" A1

MECHANICAL FLOOR PLAN - HVAC - AREA B

PLAN

NORTH

2' 4' 8'0'

PLAN

NORTH

64 SEE TYPICAL MAKEUP WATER CONNECTION DETAIL A4/AM505.

65 SEE CABINET OR INLINE EXHAUST FAN DETAIL C1/AM505.

66 SEE AIR SEPARATOR DETAIL C2/AM505.

76 LOCATE MECHANICAL PIPING AS INDICATED. COORDINATE WITH OTHER

TRADES WITH GRAVITY DRAINS AND DUCTWORK TAKING PRECEDENCE.

MINIMUM PIPE HEIGHT MUST BE 8'-0" AFF. SUSPEND ALL PIPING FROM

STRUCTURAL STEEL. PIPING MUST NOT BE SUPPORTED FROM THE ROOF

DECK.

77 PROVIDE INSULATED SUBBASE FOR TEMPERATURE SENSOR.

25 SEE AIR COMPRESSOR CONDENSER WATER PIPING DETAIL A4/AM501.

26 SEE FAN COIL UNIT PIPING DETAIL C4/AM501.

38 PROVIDE 16 GAGE, 2x2 MESH, GALVANIZED HARDWARE CLOTH OVER OPENING.

45 DDC CONTROL PANEL 120 VOLTS 1 PHASE.

50 SEE PIPE PENETRATION DETAIL C3/AP504.

52 SEE MANUAL AIR VENT DETAIL A5/AM502.

53 SEE AUTOMATIC AIR VENT DETAIL C1/AM502.

54 SEE ELBOW PIPE SUPPORT DETAIL C2/AM502.

59 SEE LOW VELOCITY DUCT LAYOUT C3/AM503.

62 SEE GLYCOL FEEDER DETAIL A1/AM505.

FC-4

4 5

A

B

C

D

P-6

4"ø CWS 2 1/2"ø CWS

3"ø CWR

4"ø CWR

L-12 72x48

5500 CFM

L-4 48x48

5500 CFM

L-5 24x24

370 CFM

M A

T C

H L

IN

E

S E

E A

M

F

O R

C O

N T

M A

T C

H L

IN

E

S E

E A

M

F

O R

C O

N T

HPAC-1

HPAC-2

HPAC-3

HIGH PRESSURE

AIR ROOM

USB5

C1

AM302

EF-5

16x16 EA

EF-4

48x48 EA

24x24 EA

24x24 EA

24x24 EA

14x14 EA

14x14 EA

2 1/2"ø CWS

4"ø CWR4"ø CWR

3/4"ø HHWS

14x14 SA

PROVIDE 32 X 32

EA OPENING

PROVIDE 14" X 14"

SA OPENING

x1

S

A

16x16 RA

PROVIDE 24" X 24"

RA OPENING

3/4"ø HHWR

2 1/2"ø CWR

2 1/2"ø CWR

2 1/2"ø CWR

2 1/2"ø CWS 2 1/2"ø CWS

VLV-11

VLV-8

VLV-9

VLV-10

TEF-4

2' X 4' X 2' EXPANSION

LOOP CENTERED ON BUILDING

EXPANSION JOINT

PIPE ANCHOR

(TYP.)

V-15

72x48 OA

SHUT OFF VALVE NORMALLY

OPEN (TYP)

59 (TYP)

BDD

BDD

T

FC-4

26 (TYP.)

MD-7

UH-4

T

UH-4

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

2' X 4' X 2' EXPANSION

LOOP CENTERED ON BUILDING

EXPANSION JOINT

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

2. LOCATE ALL THERMOSTAT AND TEMPERATURE SENSORS 5'-0" AFF.

GENERAL NOTESWORK NOTES

KEYPLAN

UTILITY SERVICES

BUILDING (USB)

GATEHOUSE

GUARD BOOTH

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:1

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM103

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

M E

C H

A N

IC

A

L E

N

LA

R G

E D

F

LO

O R

P

LA

N

S H

E E

T

O F

CMG

12829426

BRF BRF

1614696

1/4" = 1'-0" A1

MECHANICAL FLOOR PLAN - HVAC - AREA C

25 SEE AIR COMPRESSOR CONDENSER WATER PIPING DETAIL A4/AM501.

26 SEE FAN COIL UNIT PIPING DETAIL C4/AM501.

38 PROVIDE 16 GAGE, 2x2 MESH, GALVANIZED HARDWARE CLOTH OVER

OPENING.

45 DDC CONTROL PANEL 120 VOLTS 1 PHASE.

59 SEE LOW VELOCITY DUCT LAYOUT C3/AM503.

65 SEE CABINET OR INLINE EXHAUST FAN DETAIL C1/AM505.

76 LOCATE MECHANICAL PIPING AS INDICATED. COORDINATE WITH OTHER

TRADES WITH GRAVITY DRAINS AND DUCTWORK TAKING PRECEDENCE.

MINIMUM PIPE HEIGHT MUST BE 8'-0" AFF. SUSPEND ALL PIPING FROM

STRUCTURAL STEEL. PIPING MUST NOT BE SUPPORTED FROM THE ROOF

DECK.

2' 4' 8'0'

PLAN

NORTH

DSS-1

UH-1

UH-2

CU-1

5 76

A

B

C

D

A4

AM302

96" x 96"

DUCT CONNECTION

TO LOUVER (TYP.)

54" X 46"

DUCT CONNECTION TO

GENERATOR RADIATOR -

VERIFY WITH APPROVED

EQUIPMENT MANUFACTURER

(TYP.)

GENERATOR

GENERATOR

8" EP

8" PIPE DOWN TO

FLEXIBLE EXHAUST

CONNECTION ON

GENERATOR

8" EP

8" PIPE DOWN TO

FLEXIBLE EXHAUST

CONNECTION ON

GENERATOR

54x54 OA

(TYP. 2)

L-6 48x48

5000 CFM

L-7 48x48

5000 CFM

EF-6

48x48 EA

SG-2 48x48

7500 CFM

(TYP. 8)

M A

T C

H L

IN

E

S E

E A

M

F

O R

C O

N T

MAIN

ELECTRICAL

ROOM

USB6

TELECOM ROOM

USB8

GENERATOR

ROOM

USB7

A1

AM302

EG-2 16x16

1480 CFM

FOT-1

32x32 EA x4

E

A

RECTANGULAR TO

ROUND TRANSITION

(TYP INLET/OUTLET)

x5

O

A x5

O A

FUEL OIL TANK - SEE

PLUMBING FLOOR PLAN -

AREA D SHEET AP104

MOTORIZED

DAMPER

DISCHARGE CONDENSATE

DRAIN ON SPLASH BLOCK 3/4" Ø CD

T

EF-5

T

S

DSS-1

T

EF-6

T UH-2

x5

O

A

L-13 18x18

370 CFM

L-14 96x96

30000 CFM

L-15 96x96

30000 CFM

T UH-1

(TYP OF 4)

18x18 OA

M-1

M-2

EG-3 20x20

2500 CFM

x3

E

A x4

E

A ø

E A ø

E A

PROVIDE MIN. OF 2'-0"

STRAIGHT DUCT ON INLET &

OUTLET OF FAN FULL SIZE OF

FAN CONNECTION

BDDBDD

MD-8

MD-10

MD-9

MD11

DSS-2

T

S

DSS-2

CU-2

3/4"ø RS 1/2"ø RL

1/2"ø RL

28 2930

3/4"ø CD

FIRE ALARM

CLOSET

USB9

5/8" Ø RS

32x32 EA32x32 EA

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

2. LOCATE ALL THERMOSTAT AND TEMPERATURE SENSORS 5'-0" AFF.

GENERAL NOTES

WORK NOTES

KEYPLAN

UTILITY SERVICES

BUILDING (USB)

GATEHOUSE

GUARD BOOTH

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:2

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM104

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

M E

C H

A N

IC

A

L E

N

LA

R G

E D

F

LO

O R

P

LA

N

S H

E E

T

O F

CMG

12829427

BRF BRF

1614696

1/4" = 1'-0" A1

MECHANICAL FLOOR PLAN - HVAC - AREA D

11 ROUTE DUCT DOWN TO 1'0" AFF. PROVIDE TWO 48"x48" EGGCRATE TYPE

GRILLES FOR EACH DROP. COORDINATE DROP LOCATIONS WITH

ELECTRICAL PANELS. REFER TO A1/AM302 FOR SECTION CUT.

28 PROVIDE MANUFACTURER'S RECOMMENDED CLEARANCE FOR AIRFLOW

AND MAINTENANCE.

29 PIPE BOLLARDS TO PROTECT CONDENSING UNIT. SEE CIVIL DRAWINGS

SHEET CS502 FOR DETAILS.

30 PROVIDE CONDENSING UNIT WITH CONCRETE PAD AND LEGS TO ELEVATE

UNIT. BOTTOM OF UNIT MUST BE AT THE ELEVATION OF THE USB FLOOR

(10'-3").

31 PROVIDE HINGED, GRAVITY-OPERATED, SELF-CLOSING RAIN COVER.

38 PROVIDE 16 GAGE, 2x2 MESH, GALVANIZED HARDWARE CLOTH OVER

OPENING.

47 54x54 OA DUCT TO GRAVITY INTAKE VENTILATOR.

63 SEE RECTANGULAR FLEXIBLE CONNECTION DETAIL A2/AM505.

76 LOCATE MECHANICAL PIPING AS INDICATED. COORDINATE WITH OTHER

TRADES WITH GRAVITY DRAINS AND DUCTWORK TAKING PRECEDENCE.

MINIMUM PIPE HEIGHT MUST BE 8'-0" AFF. SUSPEND ALL PIPING FROM

STRUCTURAL STEEL. PIPING MUST NOT BE SUPPORTED FROM THE ROOF

DECK.

78 EQUIPMENT MANUFACTURER TO SIZE ALL REFRIGERANT PIPE SIZES PER

THEIR RECOMMENDATIONS FOR OPTIMAL PREFORMANCE.

PLAN

NORTH

2' 4' 8'0'

1 2 3 4

A

B

C

D

GR-1

GR-2 GR-3 GR-4

CCC-1 CCC-2

ROOF ACCESS

LADDER

71 71 71 7168 68 68 68

4 5 76

A

B

C

D

GI-3

GI-2

GI-1

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

2. LOCATE ALL THERMOSTAT AND TEMPERATURE SENSORS 5'-0" AFF.

GENERAL NOTES

WORK NOTES

KEYPLAN

UTILITY SERVICES

BUILDING (USB)

GATEHOUSE

GUARD BOOTH

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:2

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM105

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

M E

C H

A N

IC

A

L O

V E

R A

LL

R

O O

F P

LA

N

CMG

12829428

BRF BRF

1614696

1/8" = 1'-0" C1

MECHANICAL ROOF PLAN OVERALL - WEST

1/8" = 1'-0" A1

MECHANICAL ROOF PLAN OVERALL - EAST

4' 8' 16'0'

4' 8' 16'0'

PLAN

NORTH

PLAN

NORTH

47 54x54 OA DUCT TO GRAVITY INTAKE VENTILATOR.

68 30x30 EA DUCT TO GRAVITY RELIEF VENTILATOR.

71 SEE CURB DETAIL - METAL ROOF A1/A-301.

RR-1 6x6

50 CFM

CD-1 6x6

50 CFM

EG-1 8x8

50 CFM

6x6 RA

3/4"ø CD

CO

(TYP.)

RR-2 8x8

250 CFM

RR-1 6x6

50 CFM

DSS-3

1/2"ø RS 1/4"ø RL

(TYP. 2)

8x8 SA

UP TO EF-7

ON ROOF

T

EQUIPMENT ROOM

GH04

STO

GH03

SENTRY

GH01

TOILET

GH02

C1

AM303

A1

AM303

CB

3/4"ø CD

6x6 RA

6x6 SA

SS-1

8x8 OA UP

TO GV-1

8x8 EA

(TYP.) UC

10x10 SA

SS-1

8x8 OA

20x16 RA

CD-1 6x6

50 CFM

LS-1 8ø

200 CFM

12x16 SA

ROOF ACCESS

LADDER

MD-21

T

DSS-3

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

GENERAL NOTES

WORK NOTES

HP-1

EF-7GI-1

CU-3

1/2"ø RS

1/4"ø RL

C1

AM303

A1

AM303

CB

DN TO

DSS-3

69 70

ROOF ACCESS

LADDER

72 70

UTILITY

SERVICES

BUILDING (USB)

GATEHOUSE

GUARD BOOTH

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GREGORY R. MOSS

DIRECTOR OF WARFARE REQIUREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/1

/2

:2 :5

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-M

-G H

B D d k h e n d e rs o n .r v t

AM106

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

G A

T E

H O

U S

E

H V

A C

F

LO

O R

P

LA

N S

CMG

12829429

CPM CPM

1614696

1/2" = 1'-0" C1

GATEHOUSE FLOOR PLAN - HVAC

1 REFRIGERENT LIQUID FROM ROOFTOP HEAT PUMP. REFER TO

MANUFACTURER FOR REFRIGERANT PIPING SIZE. SEE THIS SHEET FOR

CONTINUATION.

2 REFRIGERENT SUCTION TO ROOFTOP HEAT PUMP. REFER TO

MANUFACTURER FOR REFRIGERANT PIPING SIZE. SEE THIS SHEET FOR

CONTINUATION.

3 EXHAUST DUCT TO ROOF MOUNTED EXHAUST FAN. SEE THIS SHEET FOR

CONTINUATION.

7 PROVIDE SECONDARY DRAIN AND PAN.

12 PROVIDE MANUFACTURER'S RECOMMENDED CLEARENCES FOR AIRFLOW

AND MAINTENANCE.

39 EXTEND CONDENSATE DRAIN TO BACK FLOW PREVENTER DRAIN SEE

GATEHOUSE FLOOR PLAN - PLUMBING SHEET AP105.

40 SEE AHU CONDENSATE TRAP DETAIL A1/AM501.

41 SEE RECTANGULAR FLEXIBLE CONNECTION DETAIL A2/AM505.

42 SEE DUCTLESS SPLIT AC - WALL MOUNT DETAIL C4/AM505.

44 SEE ARCHITECTURAL DRAWING FOR DOOR UNDERCUT (UC).

45 DDC CONTROL PANEL 120 VOLTS 1 PHASE.

46 SEE ARCHITECURAL REFLECTED CEILING PLAN FOR ACCESS DOORS IN

CEILING A1/A-402. COORDINATE EXACT LOCATION WITH FINAL LOCATION

OF BALANCE DAMPERS.

48 PROVIDE POLYPROPYLENE PLASTIC MOUNTING PAD UNDER

CONDENSING UNIT. SIZE MUST BE 3" BIGGER THAN CONDENSING UNIT.

69 SEE LINE SHACK DETAIL C3/AM504.

70 SEE CURB DETAIL - MODIFIED BITUMEN A3/A-301.

72 SEE CENTRIFUGAL ROOF EXHAUST FAN DETAIL A2/AM504.

1' 2' 4'0'

PLAN

NORTH

1/2" = 1'-0" A1

GATEHOUSE ROOF PLAN - HVAC

1' 2' 4'0'

PLAN

NORTH

PLAN

KEY PLAN

1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

GENERAL NOTES

WORK NOTES

KEYPLAN

UTILITY

SERVICES

BUILDING (USB)

GATEHOUSE

GUARD BOOTH

1/2"ø RS

1/4"ø RL

3/4"ø CD

CU-4

DSS-4

A1

AM107

A3

AM107

T

DSS-4

(TYP.)

1 2

DSS-4

GUARD BOOTH

FLOOR LEVEL

8' - 9"

ROOF

18' - 5"

CU-4

3/4"ø CD

1/2"ø RS

1/4"ø RL

GUARD BOOTH

GB01

ABC

GUARD BOOTH

FLOOR LEVEL

8' - 9"

ROOF

18' - 5"

CU-4

1/2"ø RS

1/4"ø RL

3/4"ø CD

DSS-4

GUARD BOOTH

GB01

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

JGG/RSF

Approved by Sally Torgler, Deputy Director Facilities, with

NSWDG, via Email

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

5/19/2020

ALG

/1

/2

:5 :5

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-M

-G B

B D d k h e n d e rs o n .r v t

AM107

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

G U

A R

D B

O O

T H

H

V A

C F

LO

O

R P

LA

N

A N

D S

C H

E D

U

LE

CMG

12829430

CPM CPM

1614696

PLAN

NORTH

2' 4' 8'0'

12 PROVIDE MANUFACTURER'S RECOMMENDED CLEARENCES FOR AIRFLOW

AND MAINTENANCE.

13 PROVIDE 18" HIGH OUTDOOR UNIT STAND FOR CU-4.

14 SEE DUCTLESS SPLIT AC-WALL DETAIL C4/AM505.

15 PROVIDE CONDENSATE DRAIN SEE DETAIL C1/AM501.

16 MOUNT REMOTE CONTROLLER TO WALL AT 48" AFF.

17 COORDINATE LOCATION OF INDOOR UNIT WITH TELEPHONE EQUIPMENT

RACK. MOUNT DSS INDOOR UNIT 8'6" AFF. USE MANUFACTURER'S

PROVIDED MOUNTING HARDWARE.

18 SECURE REFRIGERANT PIPING AND DRAIN PIPING TO WALL.

19 TELEPHONE EQUIPMENT RACK.

20 PROVIDE MANUFACTURER'S RECOMMENDED PVC LINESET COVER.

33 SEE PIPE PENETRATIONS - DETAIL C3/AP504

PLAN

NORTH

1/4" = 1'-0" C1

GUARD BOOTH FLOOR PLAN

DUCTLESS SPLIT SYSTEM SCHEDULE

MARK TYPE LOCATION

REFERIGERANT

TYPE

SUPPLY FAN DATA COOLING HEATING INDOOR UNIT ELECTRICAL OUTDOOR UNIT OUTDOOR UNIT ELECTRICAL

NOTES

TOTAL AIRFLOW

(CFM)

FAN MOTOR

(WATTS)

TOTAL COOLING

(MBH)

SENSIBLE

COOLING (MBH)

EAT DB (°F) EAT WB (°F)

MIN EFFICIENCY

(SEER)

HEATING CAPACITY

AT 47 °F (MBH)

HEATING CAPACITY

AT 17 °F (MBH)

EAT DB

(°F) FLA MCA

VOLTS PH HZ MARK LOCATION FLA

MCA MOCP VOLTS PH HZ

DSS-4 WALL-MOUNTED GUARD BOOTH R-410A 370 30 12 9.6 78 65 20.8 18 11.1 68 0.33 1 208/230 1 60 CU-4 OUTSIDE 7.83 11 28 208/230 1 60 1,2,3,4,5

1/2" = 1'-0" (AM107)

A1

GUARD BOOTH SECTION 1

1' 2' 4'0' 1/2" = 1'-0" (AM107)

A3

GUARD BOOTH SECTION 2

1' 2' 4'0'

1. PROVIDE POWER AND CONTROL WIRING FROM OUTDOOR UNIT TO INDOOR UNIT PER MANUFACTURER'S RECOMMENDATIONS.

2. PROVIDE WITH COASTAL COIL PROTECTION ON CONDENSING UNIT COIL.

3. PROVIDE WITH REMOTE CONTROLLER.

4. PROVIDE REFRIGERANT LINE SET PER MANUFACTURER'S RECOMMENDATION.

5. ELECTRICAL DATA FOR OUTDOOR UNIT INCLUDES INDOOR UNIT.

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

2. LOCATE ALL THERMOSTAT AND TEMPERATURE SENSORS 5'-0" AFF.

GENERAL NOTES

WORK NOTES

ABCD

ROOF

26' - 11"

USB FLOOR LEVEL

10' - 3"

ROOF

26' - 11"

CCC-2

4"ø CWR

4"ø CWS

FC-1

FRESH WATER

PUMP ROOM

USB2

EQUIPMENT

YARD

USB0

DOMESTIC WATER

BOOSTER PUMP SEE

PLUMBING SHEET AP101

ACCESS LADDER

AND PLATFORM

NORTH WALL AT

MECHANICAL YARD

STEEL SUPPORT

UNDER CLOSED

CIRCUIT COOLER

CONCRETE PAD - SEE

STRUCTURAL

DRAWING AS501

8x14 SA

SG-1 12x6

210 CFM6x12 SA14x16 RA

12x12 RA

P-3

16x24 OA

L-9 24x16

550 CFM

MD-2

4"ø CWR

4"ø CWR

4"ø CWS PIPE SUPPORT FOR

DOMESTIC COLD WATER

SEE PLUMBING FLOOR PLAN - AREA A

SHEET AP101

VLV-2

ABCD

ROOF

26' - 11"

USB FLOOR LEVEL

10' - 3"

ROOF

26' - 11"

MEDIUM

PRESSURE AIR

ROOM

USB4

L-11B 72x48

4675 CFM

4"ø CWR

MPAC-2

MPAP-2

2 1/2"ø CWR

CS-4

4"ø CWS

VLV-5

2"ø PWR 2"ø PWS

16x24 EA

MD

MD

30x30 EA

GR-2

12x24 EA

FULL SIZE OF UNIT

CONNECTION. PROVIDE

WITH FLEXIBLE

CONNECTION

12x20 EA 35

48x72 OA

38 (TYP.)

VIBRATION

ISOLATOR (TYP.)

BDD

L-3 48x48

6080 CFM

EF-3

28x28 EA

MD-5

ROOF

26' - 11"

P-2

USB FLOOR LEVEL

10' - 3"

ROOF

26' - 11"

AB

ET-1

FROM

CCC-1 & 2

TO SYSTEM

AS-1

3/4" MAKE-UP PIPE TO GLYCOL

FEEDER SEE PLUMBING ENLARGED

FLOOR PLAN SHEET 2 OF 4 SHEET

AP102 FOR CONTINUATION.

4"ø CWS

4"ø CWS

MEDIUM

PRESSURE AIR

ROOM

USB4

GFS-1

1" RELIEF VALVE

ROUTE

DISCHARGE TO

GLYCOL TANK

2"ø PWR

BUTTERFLY SHUTOFF

VALVES (TYP.)

STRAINER (TYP.)

FLOW CONTROL

BALANCE VALVE

(TYP.)

VIBRATION

ISOLATORS

(TYP.) REDUCER AS REQUIRED

TO MATCH PUMP INLET/OUTLET

(TYP.)

2"Ø

RELIEF

2"ø PWS

48x72 OA

L-11A 72x48

4675 CFM

MD-4

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:4

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM301

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

M E

C H

A N

IC

A

L S

E C

TI

O

N S

S

H E

E T

O

F

CMG

12829431

BRF BRF

1614696

32 CLOSED CIRCUIT COOLERS CAN BE NO HIGHER THAN THE NORTH WALL AT

THE MECHANICAL YARD.

34 SEE INLINE PUMP PIPING DETAIL C1/AM504.

35 SEE AIR COMPRESSOR CONDENSER WATER PIPING DETAIL A4/AM501.

36 SEE FAN COIL UNIT PIPING DETAIL C4/AM501.

37 SEE CONDENSER WATER PIPING DIAGRAM A1/AM610.

38 PROVIDE 16 GAGE, 2x2 MESH, GALVANIZED HARDWARE CLOTH OVER

OPENING.

45 DDC CONTROL PANEL 120 VOLTS 1 PHASE.

52 SEE MANUAL AIR VENT DETAIL A5/AM502.

54 SEE ELBOW PIPE SUPPORT DETAIL C2/AM502.

56 SEE RECTANGULAR BRANCH DUCT TAKE-OFF DETAIL A3/AM503.

62 SEE GLYCOL FEEDER DETAIL A1/AM505.

64 SEE TYPICAL MAKEUP WATER CONNECTION DETAIL A4/AM505.

65 SEE CABINET OR INLINE EXHAUST FAN DETAIL C1/AM505.

66 SEE AIR SEPARATOR DETAIL C2/AM505.

67 SEE EXPANSION TANK DETAIL B4/AM505.

2' 4' 8'0' 2' 4' 8'0'

2' 4' 8'0'1/4" = 1'-0" (AM101)

C1

SECTION AT USB1 AND USB0

1/4" = 1'-0" (AM102)

A1

SECTION AT USB3

1/4" = 1'-0" (AM102)

A4

SECTION AT PUMP

ABCD

ROOF

26' - 11"

USB FLOOR LEVEL

10' - 3"

ROOF

26' - 11"

L-12 72x48

5500 CFM

4"ø CWR

4"ø CWR

HPAC-2

HIGH PRESSURE AIR

COMPRESSOR

2 1/2"ø CWS

HPR-3A

HIGH PRESSURE

AIR RECEIVER

HIGH PRESSURE

AIR PURIFIER

L-4 48x48

5500 CFM

HIGH PRESSURE

AIR ROOM

USB5

EF-4

38 48x72 OA

BDD

24x24 EA

HPAP-4

UH-4

MD-7

ROOF

26' - 11"

USB FLOOR LEVEL

10' - 3"

GENERATOR

MUFFLER

x5

O

A

EF-6

SG-2 48x48

7000 CFM

SG-2 48x48

7000 CFM

8" EP54x54 OA

GI-3

L-14 96x96

30000 CFM

x5

O

A

BD

(BEYOND)

FLEXIBLE

CONNECTION

(TYP.)

DRAIN VALVE

AND CAP

VIBRATION ISOLATORS

(TYP. OF 4)

8"Ø EP

1/2"ø RS 1/2"ø RL 3/4"ø CD

MD

48x48 EA

32x32 EA

FAN

MOTOR

ABCD

ROOF

26' - 11"

USB FLOOR LEVEL

10' - 3"

ROOF

26' - 11"

32x32 EA

54x54 OA

SG-2 48x48

7500 CFM

(TYP OF 8)

GI-1

GI-2

GI-3

54x54 OA

54x54 OA

L-7 48x48

5000 CFM

GENERATOR (TYP)

BD

(BEYOND)

BD

(BEYOND)

BD

(BEYOND)

EF-6

UH-2

54x54 OA

55ø EA

55ø EA

8"Ø EP

8"Ø EP

CU-1

3/4"ø RS

MD

MD

MD

MUFFLER (TYP.)

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

2. LOCATE ALL THERMOSTAT AND TEMPERATURE SENSORS 5'-0" AFF.

GENERAL NOTES

WORK NOTES

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:5

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM302

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

M E

C H

A N

IC

A

L S

E C

TI

O

N S

S

H E

E T

O

F

CMG

12829432

DKH DKH

1614696

2' 4' 8'0'

1/4" = 1'-0" (AM103)

C1

SECTION AT USB

1/4" = 1'-0" (AM104)

A4

GENERATOR SECTION

1/4" = 1'-0" (AM104)

A1

SECTION AT USB

31 PROVIDE HINGED, GRAVITY-OPERATED, SELF-CLOSING RAIN COVER.

35 SEE AIR COMPRESSOR CONDENSER WATER PIPING DETAIL A4/AM501.

38 PROVIDE 16 GAGE, 2x2 MESH, GALVANIZED HARDWARE CLOTH OVER

OPENING.

65 SEE CABINET OR INLINE EXHAUST FAN DETAIL C1/AM505.

73 SEE SECTIONS B3/AS311 AND B4/AS311 FOR DETAILS ON THE STRUCTURAL

SUPPORT FOR THE FAN.

79 PROVIDE 3/4"Ø ALL THREAD ROD FROM STRUCTURE TO VIBRATION

ISOLATOR AND FROM THE VIBRATION ISOLATOR TO THE FAN. CONNECT

TO FAN PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE DOUBLE

BOLTS ON THE BOTTOM AND TOP OF THE STEEL.

2' 4' 8'0'

2' 4' 8'0'

ROOF

29' - 3"

GATEHOUSE FLOOR

LEVEL

8' - 6"

A DB C

EF-7

HP-1

GI-1

6x6 RA

8x8 SA

RR-1 6x6

50 CFM

CD-1 6x6

50 CFM

LS-1 8ø

200 CFM

3/4"ø CD TOILET

GH02

SENTRY

GH01

EQUIPMENT

GH04

8x8 EA

SS-1

EG-1 8x8

50 CFM

1 2

CU-3

8x8 RA

70 72

RR-2 8x8

250 CFM

MD-22MD-21

ROOF

29' - 3"

GATEHOUSE FLOOR

LEVEL

8' - 6"

13 2

CU-3

1/2"ø RS

3/4"Ø AUX

CONDENSATE

DRAIN

AUXILLARY DRAIN

UNDER UNIT

16x20 RA

SS-1

CD-1 6x6

50 CFM

(TYP.)

TOILET

GH02

STO

GH03

8x8 RA

1. REFER TO DRAWING AM001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

GENERAL NOTES

WORK NOTES

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GREGORY R. MOSS

DIRECTOR OF WARFARE REQIUREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/1

/2

:2 :5

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-M

-G H

B D d kh e n d e rs o n .r v t

AM303

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

G A

T E

H O

U S

E

M E

C H

A N

IC

A

L S

E C

T

IO

N S

CMG

12829433

CPM CPM

1614696

1/4" = 1'-0" (AM106)

C1

NORTH VIEW - SECTION

1/4" = 1'-0" (AM106)

A1

WEST VIEW - SECTION

2' 4' 8'0'

2' 4' 8'0'

1 REFRIGERENT LIQUID FROM ROOFTOP HEAT PUMP. REFER TO

MANUFACTURER FOR REFRIGERANT PIPING SIZE. SEE THIS SHEET FOR

CONTINUATION.

2 REFRIGERENT SUCTION TO ROOFTOP HEAT PUMP. REFER TO

MANUFACTURER FOR REFRIGERANT PIPING SIZE. SEE THIS SHEET FOR

CONTINUATION.

39 EXTEND CONDENSATE DRAIN TO BACK FLOW PREVENTER DRAIN SEE

GATEHOUSE FLOOR PLAN - PLUMBING SHEET AP105.

40 SEE AHU CONDENSATE TRAP DETAIL A1/AM501.

48 PROVIDE POLYPROPYLENE PLASTIC MOUNTING PAD UNDER CONDENSING

UNIT. SIZE MUST BE 3" BIGGER THAN CONDENSING UNIT.

69 SEE LINE SHACK DETAIL C3/AM504.

70 SEE CURB DETAIL - MODIFIED BITUMEN A3/A-301.

72 SEE CENTRIFUGAL ROOF EXHAUST FAN DETAIL A2/AM504.

74 CHANNEL FRAME SUPPORT UNDER UNIT/DRAIN PAN. PROVIDE 1/2"

DIAMETER ALL THREAD ROD UP TO STRUCTURE.

FCU

MV

MV

TO/FROM CONDENSER

WATER RETURN LINES

MANUAL VENT 1/2" VALVE,

NIPPLE AND CAP.

TEST CONNECTION FOR TESTING WITH

PRESSURE GAUGE OR THERMOMETER (TYP.)

UNION (TYP.)

1/2" BALL VALVE,

NIPPLE AND CAP

SEE A5 / AM502

THREE WAY CONTROL VALVE

CALIBRATED BALANCING

VALVE (NOTE 1)

NOTES:

1. INSTALL CALIBRATED BALANCING VALVES IN CONFORMANCE WITH

VALVE MANUFACTURER'S RECOMMENDED SPACING UP AND

DOWNSTREAM FROM PIPE CHANGES IN DIRECTION AND/OR OTHER

VALVES AND COMPONENTS IN THE PIPING.

STRAINER WITH

BLOWDOWN VALVE

INLINE PUMP

M

FLEXIBLE CONNECTION

(TYP.)

UNIT

DRAIN

PAN

INTERNAL

OPERATING

NEGATIVE STATIC

PRESSURE ("WG)

NOTES:

1. DIMENSION EQUAL TO MAXIMUM FAN INLET PRESSURE (INCH WC) +1"(MIN.)

2. DIMENSION EQUAL TO /2 (MIN.)

DRAW THRU UNIT

RETURN BEND

(CLOSED)

FAN INLET

PRESSURE

(NEGATIVE)

A

A

B

A

AHU CABINET WALL

FOR MIN SIZE SEE

CHART, SLOPE TO

DRAIN

PITCH (1/8" PER

FOOT) (TYP.)

NPT DRAIN

CONNECTION

ADAPTER

HAND-TIGHT

CLEANOUT PLUG

B

NOTES:

1. DRAIN SIZE FROM TABLE 307.2.2 (2018) IMC.

2. SIZE DSS AS RECOMMENDED BY THE DSS MANUFACTURER

MINIMUM CONDENSATE

DRAIN SIZE

EQUIPMENT CAPACITY

(TONS OF REFRIGERATION)

SIZE (IN)

3/4"

NOTES

1, 2UP TO 20

CONDENSATE DRAIN

PIPING FROM UNITS

PAVEMENT (TYP.)

EARTH (TYP.)

12"⌀ CONCRETE PIPE

18" LONG

PROVIDE STANDARD

PEA GRAVEL

FILL GRAVEL TO

APPROX. 2" FROM

THE TOP

MV MV

CONDENSER WATER SUPPLY

AND RETURN LINES

MANUAL VENT 1/2" VALVE,

NIPPLE AND CAP.

TEST CONNECTION FOR TESTING WITH

PRESSURE GAUGE OR THERMOMETER (TYP.)

UNION (TYP.)

1/2" BALL VALVE,

NIPPLE AND CAP

SEE A5 / AM502

TWO WAY TWO

POSITION CONTROL VALVE

M

CALIBRATED BALANCING

VALVE (NOTE 1)

NOTES:

1. INSTALL CALIBRATED BALANCING VALVES IN CONFORMANCE WITH

VALVE MANUFACTURER'S RECOMMENDED SPACING UP AND

DOWNSTREAM FROM PIPE CHANGES IN DIRECTION AND/OR OTHER

VALVES AND COMPONENTS IN THE PIPING.

MEDIUM OR HIGH PRESSURE

AIR COMPRESSOR

STRAINER WITH

BLOWDOWN VALVE

FLEXIBLE PIPE CONNECTOR (TYP.)

(TYP.)

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:5

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM501

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

M E

C H

A N

IC

A

L D

E

TA

IL

S

S

H E

E T

O

F

CMG

12829434

CPM CPM

1614696

NOT TO SCALEC4

FAN COIL UNIT PIPING DETAIL

NOT TO SCALEA1

CONDENSATE TRAP DRAIN DETAIL

NOT TO SCALE

C1

CONDENSATE DRAIN DETAIL

NOT TO SCALEA4

AIR COMPRESSOR CONDENSER WATER PIPING DETAIL

FLOOR DRAIN

3/4"

MAIN LINE, AIR SEPERATOR

OR EXPANSION TANK

AUTOMATIC

AIR VENT

REDUCER FULL LINE SIZE

POCKET OR 4"

DIAMETER MAX.

1/4" COPPER TUBING, FIELD

ROUTE TO FLOOR

DRAIN

BALL VALVE

WEEP HOLE

GROUT

CONCRETE ANCHORS

WELD

1/2" PLATE

WELD

ALL CHILLED WATER FLOOR PIPE SUPPORTS TO BE FULLY

INSULATED DOWN TO AND INCLUDING PLATE SUPPORTS.

NOTE:

1.

4"

MINIMUM

NOTE:

WATER PIPING

REDUCER

3/4" BALL

VALVE

3/4"

1. VENT ALL HIGH POINTS AS

INDICATED ABOVE.

3/8" BRASS PLUG

NOTES:

1. DRAIN ALL LOW POINTS AS INDICATED BELOW.

2. WHERE DIRT LEGS ARE SHOWN ON PIPE RISER DIAGRAMS AND/OR

PLANS LOCATE DRAIN AT BOTTOM OF DIRT LEG.

ELEVATION

WELDED PIPING

ELEVATION

THREADED PIPING

TYP. WATER PIPING

TYP. WATER PIPING

3/4" BALL VALVE

REDUCER, IF REQUIRED

ADAPTER TO 3/4" HOSE

THREAD, PROVIDE HOSE

CAP NUT

3/4" BALL VALVE

ADAPTER TO 3/4" HOSE

THREAD, PROVIDE

HOSE CAP NUT

HANGER ROD

LOCKING NUT

SUPPORT NUT

INSULATION

PIPE

HEAVY DUTY

CLEVIS HANGER

14 GAUGE RIBBED SHIELD

TO PROTECT INSULATION

TO STRUCTURE

NOTE:

1. HANGERS LOCATED OUTSIDE MUST BE STAINLESS STEEL.

Level 1 10' - 3"

FIRST FLOOR

10' - 3"

USB FLOOR LEVEL

10' - 3"

DOUBLE PIPE STAND

CONDENSER WATER

PIPING (TYP.)

GUSSET PLATE

FOR SUPPORT

CONCRETE FLOOR IN

MECHANICAL YARD

HIGH DENSITY POLYPROPYLENE

PLASTIC FEET SET ON

CONCRETE

SEE PIPE HANGER

DETAIL C3/AM502

(TYP)

STAINLEES STEEL

STRUT CHANNEL (TYP)

1"ø DCW

WITH INSULATION

Level 1 10' - 3"

FIRST FLOOR

10' - 3"

USB FLOOR LEVEL

10' - 3"

CONDENSER WATER OR

DOMESTIC COLD WATER

PIPING (TYP.)

GUSSET PLATE

FOR SUPPORT

CONCRETE FLOOR IN

MECHANICAL YARD

HIGH DENSITY POLYPROPYLENE

PLASTIC FEET SET ON

CONCRETE

SEE PIPE HANGER

DETAIL C3/AM502

(TYP)

STAINLEES STEEL

STRUT CHANNEL (TYP)

SINGLE PIPE

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:5

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM502

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

M E

C H

A N

IC

A

L D

E

TA

IL

S

S

H E

E T

O

F

CMG

12829435

CPM CPM

1614696

NOT TO SCALEC1

AUTOMATIC AIR VENT DETAIL

NOT TO SCALEC2

ELBOW PIPE SUPPORT DETAIL

NOT TO SCALEA5

MANUAL AIR VENT DETAIL

NOT TO SCALEC4

LOW POINT DRAIN DETAIL

NOT TO SCALEC3

PIPE SUPPORT DETAIL

1" = 1'-0" A1

EXTERIOR PIPE STAND DETAILS

INSULATED FLEXIBLE DUCT -

MAXIMUM LENGTH = 5'-0"

LINEAR SLOT DIFFUSER WITH LINED

PLENUM BOX SEE PLANS FOR LENGTH,

NO. OF SLOTS, AND CONNECTION SIZE.

RECTANGULAR TRANSITION RECTANGULAR TO ROUND

TRANSITION

ROUND 90 ELBOW SQUARE 90 ELBOW

W

W

D

D

TURNING VANES

MAX. SLOPE 1" IN 4"

ROUND DUCT

RECTANGULAR DUCT

MAX. SLOPE 1" IN 4"

1.5 x D

KEEP ONE SIDE FLAT

WHERE POSSIBLE

SEE DETAIL A1/AM503 FOR

TURNING VANE DETAILS

R S GA

SINGLE VANE SCH.

SMALL

LARGE

51 38 24

114 83 22

45°45°

S

S S S S

L

LWW

D

S= D/6 (MIN.2")

W/S= NO. OF SPACES

R= 1 1/4 S

L= 3/4 S

RBOLT, SCREW OR

WELD TO DUCT

SCREW EVERY

SIXTH VANE

BLADES IN TRANSITION ELBOWS MUST BE

DETERMINED ACCORDING TO SMALLEST WIDTH

OF ELBOW.

NOTES:

X = 20° MAX.

J = 45°

W

L

L = 1/4 W, 4" MIN.

AIRFLOW

J

X

RECTANGULAR DUCT,

SEE PLAN FOR SIZE.

TAKEOFF ON BOTH SIDES OR SINGLE SIDE AS REQUIRED BY PLANS.1.

BRANCH DUCT,

SEE PLAN FOR

SIZE.

BALANCING DAMPER WITH

LOCKING QUADRANT. PROVIDE 2" DUCT EXTENSION

TO ALLOW OPERATION OF DAMPER WITHOUT

DAMAGE TO INSULATION.

NOTES:

TAKEOFF ON BOTH SIDES OR SINGLE SIDE AS REQUIRED BY PLANS.1.

X = 20° MAX.

J = 45°

W

L

L = 1/4 W, 4" MIN.

AIRFLOW

X

J

RECTANGULAR DUCT,

SEE PLAN FOR SIZE.

ROUND DUCT, SEE

PLAN FOR SIZE.

BALANCING DAMPER WITH

LOCKING QUADRANT. PROVIDE 2" DUCT EXTENSION

TO ALLOW OPERATION OF DAMPER WITHOUT

DAMAGE TO INSULATION.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:5

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM503

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

M E

C H

A N

IC

A

L D

E

TA

IL

S

S

H E

E T

O

F

CMG

12829436

CPM CPM

1614696

NOT TO SCALEC2

LINEAR SLOT DIFFUSER DETAIL

NOT TO SCALEC3

LOW VELOCITY DUCT LAYOUT DETAIL

NOT TO SCALEA1

RECTANGULAR DUCT ELBOW TURNING VANES DETAIL

NOT TO SCALEA3

RECTANGULAR BRANCH DUCT TAKE-OFF DETAIL

NOT TO SCALEC1

ROUND BRANCH DUCT TAKE-OFF DETAIL

INSTALL PUMP LEVEL.

INSTALL CALIBRATED BALANCING VALVES IN CONFORMANCE WITH VALVE MANUFACTURER'S

RECOMMENDED SPACING UP AND DOWNSTREAM FROM PIPE CHANGES IN DIRECTION AND/OR

OTHER VALVES AND COMPONENTS IN THE PIPING.

4.

3.

2.

1.

INSTALLATION NOTES:

DRAIN VALVE WITH

HOSE CONNECTION

1/4 INCH GAUGE COCK (TYP.)

UNION OR FLANGE TYPE PIPE

CONNECTION SO PUMP CAN BE

REMOVED FOR SERVICE.

BALL VALVE (TYP.)

CHECK VALVE

IN-LINE PUMP

INSTALL PUMP SO THAT IT CAN BE REMOVED WITHOUT DISMANTLING

OR FORCING ADJACENT PIPE.

BEFORE START-UP, LUBRICATE PUMP IN ACCORDANCE WITH

MANUFACTURERS INSTRUCTIONS. (DO NOT RUN PUMP DRY.)

CALIBRATED BALANCING

VALVE (NOTE 2)

STRAINER WITH

BLOWDOWN VALVE

PRESSURE GAGE

0-60 PSIG RANGE

3/4" HHWS FROM

CWR

3/4" HHWS TO FAN

COIL

REDUCER AS REQUIRED

TO MATCH PUMP INLET/

OUTLET (TYP.)

EXTERIOR SIDE

INTERIOR SIDE

ELEVATION

SECTION

MULTIPLE SECTION

RUBBER SEAL (SEE

SPECIFICATIONS)

PIPE

WALL SLEEVE

WALL

SLEEVE

CONTINUOUS SEALANT

AS SPECIFIED

∅ PIPE THRU WALL

INSTALL SUCH THAT

PIPE SEAL MAY BE

TIGHTENED FROM

INTERIOR SIDE

1/2∅ HEADED STUDS @ 12"

SPACED RADIALLY

AROUND SLEEVE (4 MIN.)

AIR FLOW

DUCT

AIR FLOW

DUCT

GRIDS AND DAMPERS MUST NOT DAMAGE LINERS

NOTE:

ADJUSTABLE DAMPER

SUPPLY OUTLET

ADJUSTABLE DAMPER

SUPPLY OUTLET

QUALIZING GRID (WHEN

SPECIFIED ALTERNATIVE TO

EXTRACTOR)

REGISTER AND DIFFUSER CONTAIN VOLUME

CONTROL AT GRILLE. GRILLE HAS NO VOLUME

CONTROL.

GRILLE FLANGES MUST

COVER DUCT FLANGES.

EA

EXHAUST FAN

BACKDRAFT DAMPER

BIRDSCREEN

ROOF CURB, COORDINATE

W/EQUIPMENT FURNISHED

SEE ARCHITECTURAL DETAIL A3/A-301

FRONT

REMOVABLE COVER

CLOSED CELL

FOAM BLOCK

ROOF CURB. REFER

TO ARCHITECTURE

DETAIL A3/A-301

CLOSED CELL

FOAM BLOCK

REMOVABLE COVER

FRONT

SIDE VIEW

SECTION

REFRIGERANT PIPING

(TYP.)

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

ALG

JAMES E. DONAHUE, R.A.

/2

/2

:1

:5

P

M C

R e v it P ro je ct s \P

IE

R

P -1

-M

-U S

B D d k h e n d e rs o n .r v t

AM504

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

M E

C H

A N

IC

A

L D

E

TA

IL

S

S

H E

E T

O

F

CMG

12829437

CPM CPM

1614696

NOT TO SCALEC1

IN-LINE PUMP PIPING DETAIL

NOT TO SCALEA1

HYDROSTATIC SEAL DETAIL

NOT TO SCALEA4

DIFFUSER, GRILLE, & REGISTER CONNECTION DETAIL

NOT TO SCALEA2

CENTRIFUGAL ROOF EXHAUST FAN

NOT TO SCALEC3

LINE SHACK DETAIL

EXHAUST FAN

VIBRATION INSULATOR

PROVIDE SPRING AND RUBBER

COMBINATION HANGER, SELECT

FOR 1 INCH DEFLECTION UNDER

CALCULTED CORNER LOAD.

FLEX

CONNECTION

HANGER ROD

MOUNTING BRACKET

OR CHANNEL

(TYP. OF INTAKE

AND DISCHARGE)

AIR SEPARATOR

FROM SYSTEM

AUTOMATIC AIR

VENT

DRAIN VALVE

TO PUMP

SUCTION

RELIEF VALVE SET

AT 30 PSI

FULL SIZE TO GYLCOL

FEED TANK

AV

BOTTOM OF VALVE

7'- 6" AFF MINIMUM

SHUT OFF VALVE

(TYP.)

LIFTING RING 3/4"

AUTOMATIC

AIR VENT

AIR CHARGE

VALVE

TO PUMP

SUCTION

EXPANSION TANK

DRAIN VALVE WITH 3/4" HOSE

CONNECTION

FINISH FLOOR

AV

HOUSEKEEPING PAD

3/4" QUICK-FILL

BYPASS

SET PRV AT 20 PSIG

FROM BACKFLOW

PREVENTER, SEE

PLUMBING FLOOR PLAN -

AREA B SHEET AP102

FOR CONTINUATION

TO GYLCOL

FEED SYSTEM

SEE DETAIL A1/AM505

RANGE OF 0-100 PSIG

DUCT

1-1/2" POCKET SLIP

1-1/2" MIN. TO 3"

MAX. INSTALLED.

6" NOMINAL WITH

MATERIAL TAUT.

WASHER

1" FLANGE AND HEM

FLEXIBLE MATERIAL

AS SPECIFIED

1" x 1/8"

BAND IRON

BOLT ON 4" CENTERS

ALTERNATE

POSITION OF BOLT

FLANGED

CONNECTION

OF FAN SIDE

SHEET METAL AS

SPECIFIED FOR

DUCTWORK

SHEET METAL AS

SPECIFIED FOR DUCTWORK

NOTES:

1. LOCATE ON BOTH THE INTAKE AND DISCHARGE OF EQUIPMENT.

2. PROVIDE HIGH TEMPERATURE FLEXIBLE MATERIAL AT GENERATOR DISCHARGE.

GFS-1 GLYCOL FEED

SYSTEM

CONDENSER WATER

HEADER TO PUMP

SUCTION

CONDENSER WATER HEADER

FROM AIR SEPARATOR &

BEFORE PUMP SUCTION

4"

3/4" ROUTE RELIEF AND MAKE-UP

PIPING TO TOP OF GLYCOL TANK.

PROVIDE AIR GAP

NOTE: GLYCOL FEED SYSTEM INCLUDES

A PRESSURE REDUCING VALVE. SET PRV

AT 12 PSIG.

1" RELIEF PIPING FROM

AIR SEPARATOR - SEE

DETAIL C2/AM505

0-60 PSIG

3/4" DOMESTIC COLD

WATER MAKE-UP LINE - SEE

DETAIL A4/AM505

USB AND GUARD BOOTH - PROVIDE 18"

HIGH STAND AS INDICATED. BOTTOM OF

UNIT MUST STAY ABOVE 10'3" FLOOD

ELEVATION.

GATEHOUSE - PROVIDE

POLYPROPYLENE PLASTIC MOUNTING

PAD (AS SHOWN)

OUTDOOR UNIT CU-X. SECURE TO

CONCRETE PAD OR ROOF MOUNTED

WALL SLEEVE WITH CAPS

FURNISHED BY MANUFACTURER

POWER & CONTROL WIRING TO

INDOOR UNIT PER MANUFACTURER'S

RECOMMENDATIONS

AIRFLOW

AIRFLOW

TOP OF UNIT

± 8'-6" AFF

UNLESS

OTHERWISE

NOTED

INDOOR UNIT DSS-X

WALL MOUNTING BRACKET FURNISHED

BY MANUFACTURER

3/4" Ø DRAIN LINE SEE

FLOOR PLANS FOR

TERMINATION POINT

SA

INSULATED RS, RL REFRIGERANT

LINES

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .