This document provides details on a federal solicitation for pier reconstruction work at Naval Station Norfolk in Virginia. The solicitation number is N4008521R0219 and was issued by the Department of the Navy Naval Facilities Engineering Command for repairs and upgrades to Pier 3. Offerors are instructed to review the solicitation documentation in full, which includes plans, specifications, and other attachments outlining the scope of work. The project entails recapitalization of the existing pier to restore its structural integrity and extend its useful life. The response due date and planned award date are not stated but often solicitations of this type involve construction work with response windows of several weeks and awards made within a few months of issuance.
View the file
Other files
Show 40 more
Latest 50 of 79 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
POWER TRANSFORMER
POTENTIAL TRANSFORMER
CONTROL POWER TRANSFORMER
SURGE ARRESTOR
FUSED SWITCH
SWITCH
TRANSFER SWITCH
FUSIBLE LINK
MOLDED CASE CIRCUIT BREAKER
LOW VOLTAGE DRAW-OUT POWER CIRCUIT BREAKER
FUSED LOW VOLTAGE DRAW-OUT POWER CIRCUIT BREAKER
MEDIUM VOLTAGE POWER CIRCUIT BREAKER
MEDIUM VOLTAGE POWER DRAW OUT CIRCUIT BREAKER
DELTA CONNECTION
GROUNDED WYE CONNECTION
UNGROUNDED WYE CONNECTION
CURRENT TRANSFORMER - SINGLE RATION AS SHOWN
FEEDER PROTECTIVE RELAY
TRANSFORMER PROTECTIVE RELAY
TRANSIENT VOLTAGE SURGE SUPPRESSOR
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
CONTROL SWITCH
MEDIUM VOLTAGE CABLE TERMINATIONS
GROUNDING ELECTRODE CONNECTION
CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED
EXISTING CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED
NEW TO EXISTING CABLE SPLICE OR TAP
HOMERUN TO PANELBOARD. NO. OF ARROWS INDICATE NO. OF CIRCUITS.
TICKMARKS INDICATE NO. OF AWG CONDUCTORS.
REMOVE CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED
REMOVE EXISTING EQUIPMENT INDICATED
AMMETER
VOLTMETER
KILOWATT-HOUR METER
KILOWATT-HOUR METER WITH DEMAND REGISTER
FREQUENCY METER
AMMETER SWITCH
VOLTMETER SWITCH
SHUNT TRIP
GROUND FAULT PROTECTION
INDICATING LAMP
RELAY AND ANSI CONTROL FUNCTION SYMBOL.
ONE LINE COMMUNICATIONS REFERENCE
PT
CPT
CT
600/S
A
V
KHD
F
L
GFP
AS
VS
S
M
FPR
TPR
TVSS
PT
CS
,FPR
,TPR
DEMOLITION NOTE - REFER TO "DEMOLITION NOTES" FOR EACH
SHEET
NEW WORK NOTE - REFER TO "NEW WORK NOTES" FOR EACH SHEET
ROOM NUMBER
UNDERGROUND DUCTBANK, CONCRETE ENCASED, UON. DESCRIPTION AS INDICATED
LIMITS OF DEMOLITION
NEW TO EXISTING CONNECTION
EXISTING UNDERGROUND DUCTBANK, CONCRETE ENCASED, UON. DESCRIPTION AS
INDICATED
REMOVING UNDERGROUND DUCTBANK, CONCRETE ENCASED, UON. DESCRIPTION AS
INDICATED
X X
X A
TOP
SYMBOL REFERS TO DEPTH OF DUCTBANK SECTION. SEE DUCTBANK DETAILS (TOP,
MIDDLE, BOTTOM, ITS, EXISTING) REFER TO SHEETS EP504 AND EP506.
UNDERGROUND ELECTRICAL DISTRIBUTION CONCRETE ENCASED DUCTBANK SECTION
LOOKING IN DIRECTION OF ARROWS
SPARE DUCT (TYPICAL)
HEAVY LINE INDICATES BOTTOM OF DUCT
CABLE DESIGNATION (TYPICAL) DESCRIPTION PER CABLE AND CONDUIT SCHEDULES ON
SHEETS EP701 AND ET701
DUCTBANK ELEVATION CHANGE INDICATOR
PAD MOUNTED TRANSFORMER. 'T' DENOTES TRANSFORMER
IDENTIFICATION
T
HEAVY LINE INDICATES FRONT OF TRANSFORMER
GROUND CONDUCTORG
EQUIPMENT CODE CLEARANCE
EQUIPMENT MAINTENANCE/VENTILATION CLEARANCE
480Y/277V PANELBOARD.
208Y/120V PANELBOARD.
REMOVE EXISTING EQUIPMENT INDICATED
GROUND ROD
GROUNDING PIT
GP GROUNDING POINT
MANHOLE
EXISTING AREA LIGHTING POLE WITH LUMINAIRE
EQUIPMENT AS NOTED
E EQUIPMENT CONNECTION
DISCONNECT SWITCH. 3P = NO. OF POLES, 30 = SWITCH RATING, 20 =
FUSE RATING (NF INDICATES NON-FUSED), 3R INDICATES NEMA
RATING.
3P
3R
HIGH MAST LIGHTING POLE WITH LUMINAIRES.
CCTV CAMERA, WALL MOUNT DOME WITH PAN/TILT/ZOOM U.O.N.
CONNECTION TO HEAT TAPE
MOTOR CONNECTION, HP INDICATED
FEEDER CABLE DESIGNATION, SEE CABLE SCHEDULES ON SHEET EP701 AND ET701
J
M
C
18X
UTILITY POLE
C CRANE GROUNDING RECEPTACLE. SEE SHEET EL504 FOR DETAIL
DMITRI ZAICHENKO
Lic. No.042517 R E E
NI
G
NE
LANO
IS
S
E F O
R P
O N
W E
AL
TH FO
A I
N I G
V I
M
R
M O
C
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
C I
C O
R E
H
A M
P T
O N
R O
A D
S N
A V
A L
S T
A T
IO
N
N O
R F
O L
K
N O
R F
O L
K V
A
N A
V A
L S
T A
T
IO
N N
O R
F O
L K
N
O R
F O
L K
V
IR
G
IN
IA
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWFORM REVISION: 07 AUG 2018
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
GEOFFREY R. MOSS
DIRECTOR OF WARFARE REQUIREMENTS
SUBMARINE FORCES ATLANTIC
JAMES E. DONAHUE, R.A.
/2
/2
:5 :4
P
M Q
N
O R
\1 -1
\c a d d
A c ti v e
R e v it \P
IE
R
-1
-E
-v .r v t
E-001
P -0
R
E P
L A
C E
S U
B M
A R
IN
E
P
IE
R
E
LE
C
TR
IC
A
L
LE
G E
N D
DAW
12829297
DZ RAD
03/05/2021
WMS/IAS
1614696
JAS
EJA
DSN
A AMPERAGE OR AMPS
AF AMPERE FRAME
AFF ABOVE FINISHED FLOOR
AMI ADVANCED METERING INFRASTRUCTURE
AT AMPERE TRIP
BFG BELOW FINISED GRADE
BKR BREAKER
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CPT CURRENT POTENTIAL TRANSFORMER
DWG DRAWING
EA EACH
EC EMPTY CONDUIT
ELEC ELECTRICAL
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EQUIP EQUIPMENT
EX EXISTING
EXP EXPLOSION PROOF EQUIPMENT
FT FEET
GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED
GFE GOVERNMENT FURNISHED EQUIPMENT
GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED
GFI GROUND FAULT INTERRUPTER
GND GROUND
HGT HEIGHT
HMI HUMAN MACHINE INTERFACE
HP HORSEPOWER
HTC HEAT TRACE CABINET
I/O INPUT/OUTPUT
IPS INDUSTRIAL POWER STATION
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
LED LIGHT EMITTING DIODE
LTS LUMINAIRE
MCB MAIN CIRCUIT BREAKER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MLO MAIN LUGS ONLY
MM MULTI-MODE
MTD MOUNTED
MTG HT MOUNTING HEIGHT
MV MEDIUM VOLTAGE
NEC NATIONAL ELECTRICAL CODE
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NTS NOT TO SCALE
OSP OUTSIDE PLANT
PLC PROGRAMMABLE LOGIC CONTROLLER
PNL PANEL
PNLBD PANELBOARD
PVC POLYVINYL CHLORIDE CONDUIT
QU QUANTITY
REC RECEPTACLE
REQ'D REQUIRED
RGS RIGID GALVANIZED STEEL
SF6 SULFUR HEXAFLUORIDE
SM SINGLE MODE
SMFO SINGLE MODE FIBER OPTIC
SPS SHORE POWER STATION
SUB SUBSTATION
SWBD SWITCHBOARD
T TELEPHONE
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VOLTAGE OR VOLTS
VAC VOLTS ALTERNATING CURRENT
VFI VACUUM FAULT INTERRUPTOR
W WIRE
WHD WATT HOUR DEMAND
WP WEATHERPROOF
XFMR TRANSFORMER
Ø PHASE
ABBREVIATIONSELECTRICAL LEGEND (ONE-LINE DIAGRAMS)ELECTRICAL LEGEND (EXTERIOR)
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
C I
C O
R E
H
A M
P T
O N
R O
A D
S N
A V
A L
S T
A T
IO
N
N O
R F
O L
K
N O
R F
O L
K V
A
EJA
N A
V A
L S
T A
T
IO
N N
O R
F O
L K
R
F O
L K
V
IR
G
IN
IA
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWFORM REVISION: 07 AUG 2018
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
DSN
JAS
GEOFFREY R. MOSS
DIRECTOR OF WARFARE REQUIREMENTS
SUBMARINE FORCES ATLANTIC
JAMES E. DONAHUE, R.A.
DMITRI ZAICHENKO
Lic. No.042517 R
E E
NI
G
NE
LANOI
S S
E F
O R
P
O N
W E
AL
TH FO
A I
N I
G
V I
M
R
M O
C
/2
/2
:0 :0
P
M C
U s e rs
\r d u c k w o rt h \D o c u m e n ts
\P
IE
R -1
-E
-v rd u c k w o rt h .r v t
E-002
P -0
R
E P
L A
C E
S U
B M
A R
IN
E
P
IE
R
E
LE
C
TR
IC
A
L G
E N
E R
A L
N O
TE
S
DAW
12829298
DZ RAD
03/05/2021
WMS/IAS
1614696
ELECTRICAL DUCTBANK GENERAL NOTES
1 EL100, EP100 & ET100 SERIES DRAWINGS FOR ELECTRICAL DUCTBANK LAYOUTS FOR THE APPROXIMATE
HORIZONTIAL ROUTING.
2 LOCATION AND ROUTING OF CONDUITS, DUCTBANKS AND ELECTRICAL STRUCTURES SHOWN ON THE DRAWINGS ARE APPROXIMATE. PRIOR TO EXCAVATION AND INSTALLATION, THE CONTRACTOR MUST COORDINATE AND VERIFY LOCATIONS, ROUTING AND DEPTHS OF ALL CONDUITS, DUCTS AND STRUCTURES WITH ALL OTHER TRADES TO AVOID CONFLICTS WITH ALL UTILITIES AND STRUCTURAL FEATURES.
3 THE CONTRACTOR MUST COORDINATE THE ROUTING OF THE DUCTBANKS AND MAKE ANY ADJUSTMENTS REQUIRED IN HORIZONTIAL AND VERTICAL DIRECTIONS OF THE ENTIRE DUCTBANK RUN TO MISS UTILITIES
INCLUDING OTHER DUCTBANKS.
4 THE ADJUSTMENTS MUST CONSIDER THE ENTIRE CABLING RUN MUST NOT EXCEED 360 DEGREES WORTH
OF BENDS BETWEEN PULLING POINTS IN A SINGLE RUN PER THE NEC.
5 CABLE ROUTING ARE SHOWN FROM SUBSTATIONS TO THE VARIOUS EQUIPMENT. THE CONTRACTOR MUST ADJUST THE CONDUITS, DUCTBANK AND CABLING ROUTING TO COMPLY WITH THE NEC AND ROUTING THE CABLES IN A MANOR FROM THE SUBSTATIONS TO THE VARIOUS EQUIPMENT TO INCREASE THE CABLE
MANAGEMENT SCENARIOS IN THE ROUTINGS AND MANHOLES.
6 PROVIDE 20 MIL PLASTIC SHEETING IN BETWEEN DUCTBANKS WHERE DUCTBANKS COME IN CONTACT.
7 PROVIDE MECHANICAL SEALS FOR ALL CONDUITS 4 INCHES AND LARGER ENTERING MANHOLES, SUBSTATIONS, MEDIUM SWITCHES, TRANSFORMERS, SPS AND IPS STATIONS. REFER TO DETAILS ON EP500
SHEETS.
ELECTRICAL GENERAL NOTES (APPLIES TO ALL SHEETS)GENERAL DEMOLITION NOTES
1 CONDUIT AND DUCT ROUTINGS MUST NOT INTERFERE WITH NEW OR EXISTING EQUIPMENT, PIPING, OR
CONDUIT AND MUST NOT OBSTRUCT ACCESS TO ANY EQUIPMENT.
2 THE EQUIPMENT GROUND CONDUCTOR MUST BE CONNECTED TO ALL DEVICES SUCH THAT REMOVAL OF ANY DEVICE CANNOT INTERRUPT THE CONTINUITY OF THE EQUIPMENT GROUNDING CONDUCTOR TO AND FROM
OTHER DEVICES OR EQUIPMENT.
3 WIRE AND CONDUIT FOR EQUIPMENT AND MOTOR LOADS MUST BE CONTINUOUS IN SIZE AND COUNT FROM THE SOURCE TO THE FINAL CONNECTION. SIZE AND COUNT MUST BE AS INDICATED ON THE CIRCUIT HOMERUN
OR FEEDER SCHEDULE, UNLESS OTHERWISE NOTED.
4 CONTRACTOR MUST PERFORM A FEEDER, MANHOLE AND DUCT-ROUTE SURVEY PRIOR TO BEGINNING CONSTRUCTION TO VERIFY THE ROUTING OF THE EXISTING FEEDERS, AVAILABILITY OF EXISTING MANHOLES AND DUCTS INTENDED TO BE USED. PROVIDE THE CONTRACTING OFFICER WITH RESULTS OF THIS SURVEY AND SKETCH OF DUCTBANK SECTIONS SHOWING LOCATIONS OF OCCUPIED DUCTS AND CABLES TO BE
INSTALLED.
5 THE CONTRACTOR MUST PROVIDE NON-METALLIC WALL BRACKETS, NON-METALLIC CABLE RACKS, EQUIPMENT
GROUNDING AND THE LIKE IN EXISTING MANHOLES FOR ALL CABLING AND FEEDERS.
6 THE CONTRACTOR MUST DE-WATER MANHOLES AND HANDHOLES BEFORE COMMENCING WORK. THE CONTRACTORS DE-WATERING PUMPS MUST BE AVAILABLE IN CASE WATER SEEPAGE DOES NOT SUBSIDE.
UNDER NO CIRCUMSTANCES MUST OPEN CABLE SPLICES OR CUT TERMINATIONS EVER COME IN CONTACT
WITH WATER.
7 UNLESS SPECIFICALLY NOTED TO BE EXISTING, ALL WORK AND MATERIAL MUST BE PROVIDED BY THE CONTRACTOR. WHEREVER AN EXISTING TO PROPOSED CONNECTION IS REQUIRED, PROVIDE EXTENSION RINGS, SPLICES, WIRE, CONDUIT FITTINGS, AND ASSOCIATED APPURTENANCES. PERFORM ALL CUTTING AND
PATCHING AS REQUIRED TO MAKE THE CONNECTIONS.
8 THE CONTRACTOR MUST COORDINATE INSTALLATION OF ALL COMMUNICATIONS (TELEPHONE, LAN, NAVFAC UTILITIES, SCADA, CATV, PA, FIRE ALARM, ETC.) CABLES AND EQUIPMENT INTO EXISTING FACILITIES AND BUILDINGS WITH CONTRACTING OFFICER PRIOR TO COMMENCING THIS WORK. COORDINATION AND DISCUSSION BETWEEN ALL PARTIES INVOLVED WITH THIS WORK MUST TAKE PLACE IN WEEKLY MEETING AND
ADDITIONAL MEETINGS AS REQUIRED ESPECIALLY FOR THIS PURPOSE.
9 THE CONTRACTOR MUST CLOSELY STUDY THE CONSTRUCTION PLANS AND NOTES AS OUTLINED. SLIGHT DEVIATIONS FROM CONFINED WORK SPACES MAY BE NECESSARY TO FULLY COMPLETE A CONSTRUCTION AREA AS OUTLINED ON THOSE SHEETS. THE DEVIATIONS MUST BE HELD TO A MINIMUM AND MUST BE FULLY COORDINATED WITH THE CONTRACTING OFFICER. ALL SUCH DEVIATIONS MUST BE MADE WITH NO ADDITIONAL
COST TO THE GOVERNMENT.
10 DURING THE EXECUTION OF THIS WORK, THE GOVERNMENT WILL CONTINUE TO OCCUPY AND OPERATE ALL ADJACENT FACILITIES, PIERS, BERTHS, WHARFS, BUILDINGS AND UTILITIES, AND, THEREFORE, WILL REQUIRE CONTINUOUS OPERATION OF ALL EXISTING ELECTRIC AND COMMUNICATIONS SERVICES. OUTAGES REQUIRED FOR CONSTRUCTION PURPOSES MUST BE SCHEDULED FOR THE SHORTEST PRACTICAL PERIODS OF TIME, AND THEN ONLY BY PRE-ARRANGEMENT WITH THE CONTRACTING OFFICER FOR MUTUALLY AGREEABLE PERIODS.
AFTER EACH OF WHICH THE INTERRUPTION MUST CEASE AND SERVICE SHALL BE RESTORED.
11 FOR THE SCADA AND NAVFAC COORDINATION, REFER TO THE ET SERIES DRAWINGS FOR THE DUCTBANK AND
CABLING INFORMATION.
12 ROUTING FOR THE POWER COORDINATION, REFER TO THE EP SERIES DRAWINGS FOR THE DUCTBANK AND
CABLING INFORMATION.
13 INSTALL ALL ELECTRICAL EQUIPMENT WITH THE MAINTENANCE COMPARTMENTS AND CIRCUIT BREAKER
COMPARTMENTS NO MORE THAN 2 INCHES FROM THE FOUNDATIONS EDGE.
14 COORDINATE ALL DUCTBANK ROUTING WITH EXISTING AND NEW STRUCTURES. ROUTE DUCTBANKS TO AVOID
CONFLICTS.
15 THE CONTRACTOR MUST PERFORM WORK ON UNENERGIZED CABLES WITH ENERGIZED CABLES IN MANHOLES.
16 FOR DEMOLITION DUCTBANKS AND MANHOLES, PULL EXISTING CABLES BACK TO FACILITATE DEMOLITION AND PROPOSED WORK. PULL EXISTING CABLES INTO PATHWAYS AND TERMINATE CABLES TO MATCH THE EXISTING CONDITION. TEST ALL EXISTING CABLES AFTER TERMINATION. PROVIDE CABLES, AS REQUIRED, TO USE CONDUIT INDICATED. SUBDIVIDE CABLES INTO MULTIPLE CABLES TO USE CONDUITS INDICATED.
17 THE ROUTING OF THE FEEDERS IN MANHOLES AND DUCTBANKS ARE FOR BIDDING PURPOSES. THE CONTRACTOR MAY ROUTE THE FEEDERS WITHIN DIFFERENT DUCT CONFIGURATIONS TO AID WITH THE INSTALLATION. DOCUMENT THE ROUTING ON THE REDLINE AND RECORD DRAWINGS. THE CONTRACTOR IS
RESPONSIBLE FOR CUT LENGTHS OF THE FEEDERS.
18 SPLICING OF FEEDERS WITHIN MANHOLES OR UNDERGROUND IS DISCOURAGED. ALL SPLICES SHALL BE NOTED WITHIN THE CABLE PULLING PLAN AND WILL REQUIRE APPROVAL BY THE CONTRACTING OFFICER.
19 ADJUST SETTINGS OF CURRENTLY UNUSED BREAKERS TO MATCH CURRENTLY USED BREAKERS. COORDINATE
WITH GOVERNMENT FOR SETTINGS.
20 CONTRACTOR SHALL IS RESPONSIBLE FOR ALL REQUIRED CHANGES IF THE PHYSICAL SIZE OF ELECTRICAL
EQUIPMENT PROVIDED DEVIATES FROM THE BOD SHOWN IN THE DRAWINGS.
1 SEE DEMOLITION ONE-LINE DIAGRAMS AND CABLE SCHEDULES ON ED600 SERIES SHEETS.
2 REMOVE CONDUCTORS FROM CONDUITS AND DUCTS AND DISCONNECT FROM ALL POWER SOURCES AS REQUIRED TO ACCOMPLISH THE WORK OF THIS CONTRACT. REFER TO SHEETS ED SERIES DRAWINGS FOR
DEMOLITION, INCLUDING UTILITIES, DUCTBANKS AND OTHER STRUCTURES.
3 DEMOLITION OF DUCTBANKS MUST INCLUDE REMOVAL OF SECTIONS INDICATED IN ED100 SERIES DRAWINGS.
ALL MANHOLES ARE EXISTING TO REMAIN, UON.
4 CONTRACTOR MUST COORDINATE SEQUENCE AND ARRANGEMENT OF DEMOLITION OF ALL COMMUNICATIONS (TELEPHONE, LAN, NAVFAC UTILITIES, SCADA, CATV, PA, MAVFAC UTILITIES SECURITY, FIRE ALARM, ETC.)
CABLES AND EQUIPMENT WITH CONTRACTING OFFICER PRIOR TO COMMENCING THIS WORK. COORDINATION AND DISCUSSION BETWEEN ALL PARTIES INVOLVED WITH THIS WORK MUST TAKE PLACE IN WEEKLY MEETING
AND ADDITIONAL MEETINGS AS REQUIRED ESPECIALLY FOR THIS PURPOSE.
5 EXCEPT AS NOTED ELSEWHERE AND AS REQUIRED BY CONSTRUCTION PHASING, ALL EXISTING SERVICES (ELECTRIC, TELEPHONE, LAN, NAVFAC UTILITIES, CATV, PA, NAVFAC UTILITIES SECURITY, ETC.) MUST REMAIN
ACTIVE.
6 THE ENTIRE RUN OF ABANDONED CONDUITS WITHIN DUCTBANKS MUST BE GROUTED COMPLETE. GROUT ABANDONED CONDUITS WITHIN DUCTBANKS FLUSH WITH THE INTERIOR OF MANHOLES AND FLUSH WITH THE
ENDS OF THE CONDUITS.
7 SEE ELECTRICAL GENERAL NOTES FOR ADDITIONAL DEMOLITION AND REDISTRIBUTION REQUIREMENTS.
8 REMOVE ALL CABLES AND WIRING FROM CONDUITS AND BLOCKOUTS. REVIEW STRUCTURAL DRAWINGS FOR DEMOLITION OF THE EXISTING PATHWAYS. ALL EXISTING ABANDONED CONDUITS AND BLACKOUTS SHALL BE
COMPLETED GROUTED THE ENTIRE LENGTH.
9 REPAIR MANHOLE WALLS WHERE DUCTBANK IS DEMOLISHED AND OPENING NOT REUSED FOR DUCTBANK.
10 SALVAGE EXISTING FIRE ALARM MASTER BOXES AND PEDESTALS. TURN OVER TO THE GOVERNMENT.
11 BASE FIRE ALARM SHOP MUST MAKE THE BASE LOOP DISCONNECTIONS AND THE NEW SPLICES. PROVIDE A
MINIMUM OF TWO DAYS NOTICE.
12 PERFORM DEMOLITION REQUIRED FOR WORK.
13 REMOVE ALL EXPOSED WIRING, WIRE/CONDUIT, EQUIPMENT AND ASSOCIATED APPURTENANCES WITHIN THE
DRY DOCK, CATWALK, PLATFORMS AND ASSOCIATED AREAS TO PERFORM ALL WORK REQUIRED.
HIGHMAST LIGHT,
NOTE 3
E
POWER STATION,
NOTE 3
E
POWER STATION,
NOTE 2
CST
COMMUNICATION
PEDESTAL, NOTE 4
HIGHMAST LIGHT,
NOTE 3
HH
COMMUNICATION HANDHOLE
WITH PATCHLOCKS, NOTE 4
E
POWER STATION,
NOTE 3
E
MOTORIZED VEHICLE
BARRIER, NOTE 1
E L
E P
E C
MH-3374
EP EP
EP EP
EP EC2 EP
EP EPEP
EP
E P
E C
E L
EP EP
EPEP
EP EP EC
EPEP
EP EP
EP
EP
ELEL
CE-48
MH-3373
NOTE 5
SUBSTATION
CEP-192, NOTE 6.
E P
EL
EP
EP EP EP
EP EPEP
EC EP
EPEP
EP
EP
EL
EV
D E
M O
L I T
I O
N
S
I T
E
P
L A
N
P
I E
R
T
ED101
12829299
AS NOTED
DZ RAD DAW
FI
LE
N
AM
E:
Q
:\N O
R\
0-
\c ad d\
_A ct ive
Pi er
\E
LE
CT
RI
CA
L
DE
M O
LI
TI
O N\
P0
-1
-E D1
.d wg L
AY
O
UT
N
AM
E:
P
5-
6-
ED
P
LO
TT
ED
: T hu rs da y, M ar ch
5,
- 2
:1 5p m U
SE
R:
rd uc kw or th
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
T
F
T
H E
A V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M S
C
M
M A
N D
UNCLASSIFIED
U N
C L
A S
S I F
I E
D
UNCLASSIFIED
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
P -0
R
E P
LA
C
E S
U B
M A
R
IN
E P
IE
R
N
A V
A L
S
TA
TI
O
N N
O R
FO
LK
N O
R
FO
LK
, V
IR
G
IN
IA
1614696
WMS/IAS
EJA
DSN
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C C
I C O
R E
H
A M
P
TO
N R
O A
D S
N A
V A
L S
TA
TI
O N
N O
R
FO
LK
N O
R
FO
LK
, V
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
GEOFFREY R. MOSS
DIRECTOR OF WARFARE REQUIREMENTS
SUBMARINE FORCES ATLANTIC
03/05/2021
JAMES E. DONAHUE, R.A.
GENERAL NOTES:
40'10'0 20'
PLAN
NORTH
SCALE: 1" = 20'
DEMOLITION SITE PLAN - PIER 3T
1. REFER TO CABLE AND CONDUIT SCHEDULE, SHEET EP701 FOR
CABLE DESCRIPTION.
NOTES:
1. DISCONNECT AND REMOVE EQUIPMENT. REMOVE CIRCUIT
CONDUCTORS TO GUARDHOUSE PANELBOARD.
2. DISCONNECT AND REMOVE EQUIPMENT. TURN EQUIPMENT
OVER TO GOVERNMENT. REMOVE FEEDER BACK TO
SUBSTATION CEP-192.
3. DISCONNECT AND REMOVE EQUIPMENT. REMOVE FEEDER
BACK TO SUBSTATION CEP-192.
4. DISCONNECT AND REMOVE TELECOMMUNICATION EQUIPMENT.
REMOVE CONDUCTORS BACK TO MANHOLE CE-48.
5. DISCONNECT AND REMOVE GUARDHOUSE ELECTRICAL SYSTEM
COMPLETE. REMOVE SERVICE CONDUCTORS BACK TO CEP-192.
6. DISCONNECT AND REMOVE SUBSTATION CEP-192, 35KV,
3.75KVA SWITCHGEAR AND ASSOCIATED EQUIPMENT. REMOVE
SERVICE FEEDER BACK TO 35KV SWITCH SW-253, LEG #5,
LOCATED AT HEAD OF PIER 5 APPROXIMATELY 600FT NORTH.
U E
U E
UE
UE
UE
UE
UE
U F
U F
U F
U F
U F
U F
S T
M
STM
STM
S T
M
S T
M
S T
M
STM
STM
STM
STM
STM
SAN
SAN
SAN
SAN
SAN
W
W
W
W
W
W
AREA 101AREA 102
AREA 103AREA 104AREA 105AREA 106AREA 107
AREA 108AREA 109
AREA 110
AREA 111
AREA 112
AREA 113
AREA 161AREA 162AREA 163
KEY PLAN
PLAN
NORTH
AREA 114
AutoCAD SHX Text
10" E. SAN.
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
DMITRI ZAICHENKO
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text Lic. No. 042517
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
AST
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
CO
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
VHP20
AutoCAD SHX Text
VHP21
AutoCAD SHX Text
CEP74
AutoCAD SHX Text
CEP89
AutoCAD SHX Text
CEP29
NOTE 4
NOTE 1
NOTE 1
NOTE 1
NOTE 1
NOTE 2
NOTE 2
NOTE 2
NOTE 2
NOTE 2
NOTE 3
TELECOMMUNICATIONS
DISTRIBUTION EQUIPMENT
NOTE 1
D E
M O
L I T
I O
N
S
I T
E
P
L A
N
A
R E
A
ED103
12829300
AS NOTED
FI
LE
N
AM
E:
Q
:\N O
R\
0-
\c ad d\
_A ct ive
Pi er
\E
LE
CT
RI
CA
L
DE
M O
LI
TI
O N\
P0
-1
-E D1
.d wg L
AY
O
UT
N
AM
E:
E D1
D
EM
O
LI
TI
O N
SI
TE
P
LA
N
- A
RE
A
P
LO
TT
ED
: T hu rs da y, M ar ch
5,
- 2
:1 6p m U
SE
R:
rd uc kw or th
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
UNCLASSIFIED
U N
C L
A S
S I F
I E
D
UNCLASSIFIED
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
P -0
R
E P
LA
C
E S
U B
M A
R
IN
E P
IE
R
N
A V
A L
S
TA
TI
O
N N
O R
FO
LK
N O
R
FO
LK
, V
IR
G
IN
IA
1614696
WMS/IAS
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C C
I C O
R E
H
A M
P
TO
N R
O A
D S
N A
V A
L S
TA
TI
O N
N O
R
FO
LK
N O
R
FO
LK
CHIEF ENG/ARCH
FIRE PROTECTION
GEOFFREY R. MOSS
DIRECTOR OF WARFARE REQUIREMENTS
SUBMARINE FORCES ATLANTIC
03/05/2021
JAMES E. DONAHUE, R.A.
DEMOLITION NOTES:
1. DISCONNECT AND REMOVE POLE MOUNTED LUMINAIRE. REMOVE
ASSOCIATED WIRING.
2. DISCONNECT AND REMOVE UNDERGROUND LIGHTING CIRCUIT
COMPLETE.
3. DISCONNECT AND REMOVE LIGHTING CIRCUIT TO THE LAST ACTIVVE
DEVICE OR SPLICE.
4. DISCONNECT AND REMOVE TELECOMMUNICATION DISTRIBUTION
EQUIPMENT.
40'10'0 20'
1" = 20'
PLAN
NORTH
SCALE: 1" = 20'
DEMOLITION SITE PLAN - AREA 103
M A
T C
H L
I N
E
S
D
U E
U E
UE
UE
UE
UE
UE
U F
U F
U F
U F
U F
U F
STM
S T
M
STM
S T
M
S T
M
S T
M
STM
STM
STM
STM
SAN
SAN
SAN
SAN
W
W
W
W
AREA 101AREA 102
AREA 103AREA 104AREA 105AREA 106AREA 107
AREA 108AREA 109
AREA 110
AREA 111
AREA 112
AREA 113
AREA 161AREA 162AREA 163
KEY PLAN
PLAN
NORTH
AREA 114
GENERAL NOTES:
1. CONTRACTOR TO COORDINATE DEMOLITION OF CATV
INFRASTRUCTURE WITH COX COMMUNICATIONS PRIOR TO
DEMOLITION OF PIER.
2. COORDINATE DEMOLITION WORK WITH PROJECT PHASING PLAN.
REFER TO SHEETS G-121 THROUGH G-128 FOR ADDITIONAL
INFORMATION.
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
3RD STREET
AutoCAD SHX Text 10" E. W.
AutoCAD SHX Text 8" E. W.
AutoCAD SHX Text
E. UG. ELEC.
AutoCAD SHX Text
AM
AutoCAD SHX Text
TBM #3 ELEV. = 8.26
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DMITRI ZAICHENKO
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text Lic. No. 042517
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
AST
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
CO
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
VHP20
AutoCAD SHX Text
VHP21
AutoCAD SHX Text
CEP74
AutoCAD SHX Text
CEP89
EX PAD-MOUNTED
SWITCH "171"
EX PAD-MOUNTED
TRANSFORMER
"PMT23"
E
E
EMH-19B
EMH-19A
EMH-19
1A
19C
19D
19E
E
N1
E402E208
EXISTING DUCTBANK
E X
I S
T I
G
U C
T B
A N
K
EXISTING DUCTBANK
NOTE 1
NOTE 1
X
X
X
EXISTING DUCTBANK
E208
PANEL MDP23
EXISTING
DUCTBANK
ET22
E402E171
EXISTING
DUCTBANK
E402
E
NOTE 4
X X
X X
NOTE 1
SUBSTATION
CEP-12, NOTE 2.
NOTE 3
E402
NOTE 1
NOTE 1
NOTE 1
NOTE 1
NOTE 1
NOTE 1
NOTE 1
NOTE 5
NOTE 6
NOTE 7
NOTE 6
NOTE 5
NOTE 6
NOTE 9
NOTE 5, 11
NOTE 8
TMH-CE13
NOTE 10
NOTE 10
NOTE 5
NOTES 9, 10
NOTE 10
NOTE 2
TELECOMMUNICATIONS
DISTRIBUTION EQUIPMENT
FIBER OPTIC
DISTRIBUTION
EQUIPMENT
NOTE 10
CCTV EQUIPMENT
NOTE 12
NOTE 1
D E
M O
L I T
I O
N
S
I T
E
P
L A
N
A
R E
A
ED104
12829301
AS NOTED
DZ RAD DAW
FI
LE
N
AM
E:
Q
:\N O
R\
0-
\c ad d\
_A ct ive
Pi er
\P
IE
RP
5-
6-
ED
4.
dw g L
AY
O
UT
N
AM
E:
D
EM
O
LI
TI
O
N
SI
TE
P
LA
N
- A
RE
A
P
LO
TT
ED
: T hu rs da y, M ar ch
5,
- 2 :1
7p m
U
SE
R:
rd uc kw or th
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
UNCLASSIFIED
U N
C L
A S
S I F
I E
D
UNCLASSIFIED
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
P -0
R
E P
LA
C
E S
U B
M A
R
IN
E P
IE
R
N
A V
A L
S
TA
TI
O
N N
O R
FO
LK
N O
R
FO
LK
, V
IR
G
IN
IA
1614696
WMS/IAS
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C C
I C O
R E
H
A M
P
TO
N R
O A
D S
N A
V A
L S
TA
TI
O N
N O
R
FO
LK
N O
R
FO
LK
CHIEF ENG/ARCH
FIRE PROTECTION
GEOFFREY R. MOSS
DIRECTOR OF WARFARE REQUIREMENTS
SUBMARINE FORCES ATLANTIC
03/05/2021
JAMES E. DONAHUE, R.A.
40'10'0 20'
PLAN
NORTH
SCALE: 1" = 20'
DEMOLITION SITE PLAN - AREA 104
M A
T C
H L
I N
E
S
U E
U E
UE
UE
UE
UE
UE
U F
U F
U F
U F
U F
U F
STM
S T
M
STM
S T
M
S T
M
S T
M
STM
STM
STM
STM
SAN
SAN
SAN
SAN
W
W
W
W
AREA 101AREA 102
AREA 103AREA 104AREA 105AREA 106AREA 107
AREA 108AREA 109
AREA 110
AREA 111
AREA 112
AREA 113
AREA 161AREA 162AREA 163
KEY PLAN
PLAN
NORTH
AREA 114
DEMOLITION NOTES:
1. DISCONNECT AND REMOVE ELECTRICAL CONDUCTORS
2. DEMOLISH SUBSTATION COMPLETE.
3. DEMOLISH 75KVA, 480V DRY-TYPE TRANSFORMER, FOUR SETS OF
DISCONNECTS/RECEPTACLES, AND ASSOCIATED WIRING.
4. DEMOLISH SHORE POWER PEDESTAL AND ASSOCIATED FEEDERS.
5. DISCONNECT AND REMOVE POLE MOUNTED LUMINAIRE. REMOVE
ASSOCIATED WIRING.
6. DISCONNECT AND REMOVE UNDERGROUND LIGHTING CIRCUIT
COMPLETE.
7. DISCONNECT AND REMOVE LIGHTING CONTROLLER AND ASSOCIATED
CIRCUITRY.
8. DISCONNECT AND REMOVE LIGHTING CIRCUIT TO THE LAST ACTIVE
DEVICE OR SPLICE.
9. DISCONNECT AND REMOVE TELECOMMUNICATION DISTRIBUTION
EQUIPMENT.
10. 10. PULL TELECOMMUNICATIONS CABLING BACK TO TMH-CE12. COIL
CABLING INSIDE TMH-CE12 FOR FUTURE USE.
11. DISCONNECT CCTV CAMERA AND ASSOCIATED EQUIPMENT. TURN
CCTV EQUIPMENT CABINET TO THE GOVERNMENT.
12. DISCONNECT AND REMOVE CCTV EQUIPMENT POWER CIRCUIT BACK
TO OCPD.
GENERAL NOTES:
1. CONTRACTOR TO COORDINATE DEMOLITION OF CATV
INFRASTRUCTURE WITH COX COMMUNICATIONS PRIOR TO
DEMOLITION OF PIER.
2. ALL ELECTRICAL INFRASTRUCTURE IN SHADED AREA NOT NOTED
ABOVE IS TO BE DEMOLISHED. COORDINATE SALVAGE/RETURN OF
ELECTRICAL EQUIPMENT WITH GOVERNMENT.
3. REFER TO 15KV SYSTEM ONE-LINE DIAGRAM - DEMOLITION ON SHEET
EP602 FOR ADDITIONAL INFORMATION.
4. COORDINATE DEMOLITION WORK WITH PROJECT PHASING PLAN.
REFER TO SHEETS G-121 THROUGH G-128 FOR ADDITIONAL
INFORMATION.
5. REFER TO CABLE AND CONDUIT SCHEDULE ON SHEET EP701 FOR
CABLE INFORMATION.
MATCHLINE - SEE ED109
M A
T C
H L
I N
E
S
AutoCAD SHX Text
E. UG. FUEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text W.V.
AutoCAD SHX Text W.V.
AutoCAD SHX Text W.V.
AutoCAD SHX Text
TC 8.33
AutoCAD SHX Text 7.81
AutoCAD SHX Text
1-ST. BLOCK BLDG #23
AutoCAD SHX Text
TC 7.87
AutoCAD SHX Text 7.41
AutoCAD SHX Text
TC 7.82
AutoCAD SHX Text 7.39
AutoCAD SHX Text
15" E. SAN.
AutoCAD SHX Text 10" E. S.
AutoCAD SHX Text 4" E. S.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 12" E. O.W.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
E. UG. FUEL
AutoCAD SHX Text
E. UG. FUEL
AutoCAD SHX Text 12" E.
AutoCAD SHX Text
AutoCAD SHX Text 12" E.
AutoCAD SHX Text
SAN.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 7.58
AutoCAD SHX Text
BA
AutoCAD SHX Text
BC
AutoCAD SHX Text
BD
AutoCAD SHX Text
BD
AutoCAD SHX Text 7.61
AutoCAD SHX Text 7.67
AutoCAD SHX Text 7.87
AutoCAD SHX Text 7.70
AutoCAD SHX Text 7.6
AutoCAD SHX Text 7.65
AutoCAD SHX Text 7.58
AutoCAD SHX Text 7.67
AutoCAD SHX Text 7.75
AutoCAD SHX Text 7.70
AutoCAD SHX Text 7.62
AutoCAD SHX Text 7.77
AutoCAD SHX Text 7.56
AutoCAD SHX Text 7.65
AutoCAD SHX Text 7.53
AutoCAD SHX Text 7.44
AutoCAD SHX Text 7.18
AutoCAD SHX Text 7.23
AutoCAD SHX Text 7.29
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DMITRI ZAICHENKO
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text Lic. No. 042517
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
AST
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
CO
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
VHP20
AutoCAD SHX Text
VHP21
AutoCAD SHX Text
CEP74
AutoCAD SHX Text
CEP89
VAULT #22,
VAULT #3,
NOTE 1
VAULT #3A,
NOTE 1
EX SUBSTATION,
4000KVA,
34,500-480Y/277V "N1"
EX SUBSTATION,
4000KVA,
34,500-480Y/277V
"S1"
INDUSTRIAL
TRANSFORMER T1,
NOTE 4
J
H
K
D
G
F
E
E X
I S
T I N
G
D
U C
T B
A N
K
2020 20
D
L
K
J
H
K
D
G
F
E
J
E X
I S
T I N
G
D
U C
T B
A N
K
20 20
20 2020
20 24
G
F
E
L
K
J
H
K
J
E X
I S
T I N
G
D
U C
T B
A N
K
20 20
20 2420
G
F
E
H
E X
I S
T I N
G
D
U C
T B
A N
K
20 2420
L
F
G
E
E X
I S
T I N
G
D
U C
T B
A N
K
20 2420
L
H
20 24
20 24
NOTE 2, TYP
NOTE 2,
TYP
NOTE 2,
TYP
NOTE 3
NOTE 5
D E
M O
L I T
I O
N
S
I T
E
P
L A
N
A
R E
A
ED105
12829302
AS NOTED
DZ RAD DAW
FI
LE
N
AM
E:
Q
:\N O
R\
0-
\c ad d\
_A ct ive
Pi er
\P
IE
RP
5-
6-
ED
5.
dw g L
AY
O
UT
N
AM
E:
D
EM
O
LI
TI
O
N
SI
TE
P
LA
N
- A
RE
A
P
LO
TT
ED
: T hu rs da y, M ar ch
5,
- 2 :1
7p m
U
SE
R:
rd uc kw or th
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
UNCLASSIFIED
U N
C L
A S
S I F
I E
D
UNCLASSIFIED
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
P -0
R
E P
LA
C
E S
U B
M A
R
IN
E P
IE
R
N
A V
A L
S
TA
TI
O
N N
O R
FO
LK
N O
R
FO
LK
, V
IR
G
IN
IA
1614696
WMS/IAS
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C C
I C O
R E
H
A M
P
TO
N R
O A
D S
N A
V A
L S
TA
TI
O N
N O
R
FO
LK
N O
R
FO
LK
CHIEF ENG/ARCH
FIRE PROTECTION
GEOFFREY R. MOSS
DIRECTOR OF WARFARE REQUIREMENTS
SUBMARINE FORCES ATLANTIC
03/05/2021
JAMES E. DONAHUE, R.A.
40'10'0 20'
PLAN
NORTH
SCALE: 1" = 20'
DEMOLITION SITE PLAN - AREA 105
M A
T C
H L
I N
E
S
M A
T C
H L
I N
E
S
U E
U E
UE
UE
UE
UE
UE
U F
U F
U F
U F
U F
U F
STM
S T
M
STM
S T
M
S T
M
S T
M
STM
STM
STM
STM
SAN
SAN
SAN
SAN
W
W
W
W
AREA 101AREA 102
AREA 103AREA 104AREA 105AREA 106AREA 107
AREA 108AREA 109
AREA 110
AREA 111
AREA 112
AREA 113
AREA 161AREA 162AREA 163
KEY PLAN
PLAN
NORTH
AREA 114
DEMOLITION NOTES:
1. DEMOLISH EXISTING ELECTRICAL VAULT.
2. ELECTRICAL CONDUITS AND CABLING TO BE REMOVED BACK TO
MANHOLES 1A, N1, AND S1. SEE SHEETS ED104 AND 109 FOR
LOCATIONS.
3. REMOVE/SALVAGE EXISTING 4MVA ELECTRICAL SUBSTATION AND
TURN OVER TO THE GOVERNMENT.
4. REMOVE/SALVAGE EXISTING 500KVA THREE PHASE TRANSFORMER
AND TURN OVER TO THE GOVERNMENT.
5. REMOVE/SALVAGE EXISTING 480V INDUSTRIAL POWER STATION AND
TURN OVER TO THE GOVERNMENT.
GENERAL NOTES:
1. CONTRACTOR TO COORDINATE DEMOLITION OF CATV
INFRASTRUCTURE WITH COX COMMUNICATIONS PRIOR TO
DEMOLITION OF PIER.
2. ALL ELECTRICAL INFRASTRUCTURE IN SHADED AREA NOT NOTED
ABOVE IS TO BE DEMOLISHED. COORDINATE SALVAGE/RETURN OF
ELECTRICAL EQUIPMENT WITH GOVERNMENT.
3. REFER TO CABLE AND CONDUIT SCHEDULE ON SHEET EP701 FOR
CABLE DESCRIPTION.
4. COORDINATE DEMOLITION WORK WITH PROJECT PHASING PLAN.
REFER TO SHEETS G-121 THROUGH G-128 FOR ADDITIONAL
INFORMATION.
5. AS INDICATED ON EXISTING PIER 3 DEMOLITION DRAWINGS, REMOVE
AND TURN OVER TO THE GOVERNMENT SIX-(6) 4MVA UNIT
SKID-MOUNTED SUBSTATIONS, TWO-(2) 500KVA INDUSTRIAL POWER
PAD-MOUNTED TRANSFORMERS, AND FOUR-(4) 600V-800A INDUSTRIAL
POWER STATIONS (IPS). THE CONTRACTOR IS RESPONSIBLE TO
DELIVER THE DEMOLISHED AND REMOVED EQUIPMENT TO A
DESIGNATED STORAGE LOCATION BY THE GOVERNMENT. THE
CONTRACTOR IS RESPONSIBLE TO HANDLE WITH CARE ALL REMOVED
EQUIPMENT, SO THAT THE UNIT SUBSTATIONS SECONDARY
BUSHINGS ARE NOT BEING BROKEN OR DAMAGED DURING THE
REMOVAL OFF THE PIER AND DELIVERING TO THE STORAGE
LOCATION. THE POC TO COORDINATE THE DELIVERING OF THE
EQUIPMENT REMOVED FROM PIER 3 IS MR. MARVIN VAUGHN,
MARVIN.VAUGHN2@NAVY.MIL, 757-341-0743.
AutoCAD SHX Text
DMITRI ZAICHENKO
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text Lic. No. 042517
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
AST
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
CO
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
VHP20
AutoCAD SHX Text
VHP21
AutoCAD SHX Text
CEP74
AutoCAD SHX Text
CEP89
VAULT #21,
VAULT #2,
NOTE 1
VAULT #2A
NOTE 1
EX SUBSTATION,
4000KVA,
34,500-480Y/277V
"N3"
EX SUBSTATION,
4000KVA,
34,500-480Y/277V
"S3"
INDUSTRIAL
TRANSFORMER T2,
NOTE 4
EX SUBSTATION,
4000KVA,
34,500-480Y/277V
"N2"
EX SUBSTATION,
4000KVA,
34,500-480Y/277V
"S2"
F
G
E X
I S
T I N
G
D
U C
T B
A N
K
20 2420
L
G
F
L
E X
I S
T I N
G
D
U C
T B
A N
K
20 2420
F
G
L
E X
I S
T I N
G
D
U C
T B
A N
K
24 20
24 20
NOTE 2, TYP
NOTE 3
NOTE 5
NOTE 2, TYP
NOTE 2, TYP
NOTE 2, TYP
NOTE 3
D E
M O
L I T
I O
N
S
I T
E
P
L A
N
A
R E
A
ED106
12829303
AS NOTED
DZ RAD DAW
FI
LE
N
AM
E:
Q
:\N O
R\
0-
\c ad d\
_A ct ive
Pi er
\P
IE
RP
5-
6-
ED
6.
dw g L
AY
O
UT
N
AM
E:
D
EM
O
LI
TI
O
N
SI
TE
P
LA
N
- A
RE
A
P
LO
TT
ED
: T hu rs da y, M ar ch
5,
- 2 :1
8p m
U
SE
R:
rd uc kw or th
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
UNCLASSIFIED
U N
C L
A S
S I F
I E
D
UNCLASSIFIED
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
P -0
R
E P
LA
C
E S
U B
M A
R
IN
E P
IE
R
N
A V
A L
S
TA
TI
O
N N
O R
FO
LK
N O
R
FO
LK
, V
IR
G
IN
IA
1614696
WMS/IAS
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C C
I C O
R E
H
A M
P
TO
N R
O A
D S
N A
V A
L S
TA
TI
O N
N O
R
FO
LK
N O
R
FO
LK
CHIEF ENG/ARCH
FIRE PROTECTION
GEOFFREY R. MOSS
DIRECTOR OF WARFARE REQUIREMENTS
SUBMARINE FORCES ATLANTIC
03/05/2021
JAMES E. DONAHUE, R.A.
40'10'0 20'
PLAN
NORTH
SCALE: 1" = 20'
DEMOLITION SITE PLAN - AREA 106
M A
T C
H L
I N
E
S
DEMOLITION NOTES:
1. DEMOLISH EXISTING ELECTRICAL VAULT.
2. ELECTRICAL CONDUITS AND CABLING TO BE REMOVED BACK TO
MANHOLES 1A, N1, AND S1. SEE SHEETS ED104 AND 109 FOR
LOCATIONS.
3. REMOVE/SALVAGE EXISTING 4MVA ELECTRICAL SUBSTATION AND
TURN OVER TO THE GOVERNMENT.
4. REMOVE/SALVAGE EXISTING 500KVA THREE PHASE TRANSFORMER
AND TURN OVER TO THE GOVERNMENT.
5. REMOVE/SALVAGE EXISTING 480V INDUSTRIAL POWER STATION AND
TURN OVER TO THE GOVERNMENT.
U E
U E
UE
UE
UE
UE
UE
U F
U F
U F
U F
U F
U F
STM
S T
M
STM
S T
M
S T
M
S T
M
STM
STM
STM
STM
SAN
SAN
SAN
SAN
W
W
W
W
AREA 101AREA 102
AREA 103AREA 104AREA 105AREA 106AREA 107
AREA 108AREA 109
AREA 110
AREA 111
AREA 112
AREA 113
AREA 161AREA 162AREA 163
KEY PLAN
PLAN
NORTH
AREA 114
M A
T C
H L
I N
E
S
GENERAL NOTES:
1. CONTRACTOR TO COORDINATE DEMOLITION OF CATV
INFRASTRUCTURE WITH COX COMMUNICATIONS PRIOR TO
DEMOLITION OF PIER.
2. ALL ELECTRICAL INFRASTRUCTURE IN SHADED AREA NOT NOTED
ABOVE IS TO BE DEMOLISHED. COORDINATE SALVAGE/RETURN OF
ELECTRICAL EQUIPMENT WITH GOVERNMENT.
3. REFER TO CABLE AND CONDUIT SCHEDULE ON SHEET EP701 FOR
CABLE DESCRIPTION.
4. COORDINATE DEMOLITION WORK WITH PROJECT PHASING PLAN.
REFER TO SHEETS G-121 THROUGH G-128 FOR ADDITIONAL
INFORMATION.
5. AS INDICATED ON EXISTING PIER 3 DEMOLITION DRAWINGS, REMOVE
AND TURN OVER TO THE GOVERNMENT SIX-(6) 4MVA UNIT
SKID-MOUNTED SUBSTATIONS, TWO-(2) 500KVA INDUSTRIAL POWER
PAD-MOUNTED TRANSFORMERS, AND FOUR-(4) 600V-800A INDUSTRIAL
POWER STATIONS (IPS). THE CONTRACTOR IS RESPONSIBLE TO
DELIVER THE DEMOLISHED AND REMOVED EQUIPMENT TO A
DESIGNATED STORAGE LOCATION BY THE GOVERNMENT. THE
CONTRACTOR IS RESPONSIBLE TO HANDLE WITH CARE ALL REMOVED
EQUIPMENT, SO THAT THE UNIT SUBSTATIONS SECONDARY
BUSHINGS ARE NOT BEING BROKEN OR DAMAGED DURING THE
REMOVAL OFF THE PIER AND DELIVERING TO THE STORAGE
LOCATION. THE POC TO COORDINATE THE DELIVERING OF THE
EQUIPMENT REMOVED FROM PIER 3 IS MR. MARVIN VAUGHN,
MARVIN.VAUGHN2@NAVY.MIL, 757-341-0743.
AutoCAD SHX Text
DMITRI ZAICHENKO
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text Lic. No. 042517
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
AST
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text
UST
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text
XFR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
AST
AutoCAD SHX Text M
AutoCAD SHX Text
CO
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
VHP20
AutoCAD SHX Text
VHP21
AutoCAD SHX Text
CEP74
AutoCAD SHX Text
CEP89
VAULT #1A
VAULT #1
NOTE 1
VAULT #20
NOTE 1
NOTE 2, TYP NOTE 2, TYP
E X
I S
T I N
G
D
U C
T B
A N
K
D E
M O
L I T
I O
N
S
I T
E
P
L A
N
A
R E
A
ED107
12829304
AS NOTED
DZ RAD DAW
FI
LE
N
AM
E:
Q
:\N O
R\
0-
\c ad d\
_A ct ive
Pi er
\P
IE
RP
5-
6-
ED
7.
dw g L
AY
O
UT
N
AM
E:
D
EM
O
LI
TI
O
N
SI
TE
P
LA
N
- A
RE
A
P
LO
TT
ED
: T hu rs da y, M ar ch
5,
- 2 :1
9p m
U
SE
R:
rd uc kw or th
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
UNCLASSIFIED
U N
C L
A S
S I F
I E
D
UNCLASSIFIED
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
P -0
R
E P
LA
C
E S
U B
M A
R
IN
E P
IE
R
N
A V
A L
S
TA
TI
O
N N
O R
FO
LK
N O
R
FO
LK
, V
IR
G
IN
IA
1614696
WMS/IAS
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C C
I C O
R E
H
A M
P
TO
N R
O A
D S
N A
V A
L S
TA
TI
O N
N O
R
FO
LK
N O
R
FO
LK
CHIEF ENG/ARCH
FIRE PROTECTION
GEOFFREY R. MOSS
DIRECTOR OF WARFARE REQUIREMENTS
SUBMARINE FORCES ATLANTIC
03/05/2021
JAMES E. DONAHUE, R.A.
DEMOLITION NOTES:
40'10'0 20'
PLAN
NORTH
SCALE: 1" = 20'
DEMOLITION SITE PLAN - AREA 107
M A
T C
H L
I N
E
S
1. DEMOLISH EXISTING ELECTRICAL VAULT.
2. ELECTRICAL CONDUITS AND CABLING TO BE REMOVED BACK TO
MANHOLES 1A, N1, AND S1. SEE SHEETS ED104 AND 109 FOR
LOCATIONS.
U E
U E
UE
UE
UE
UE
UE
U F
U F
U F
U F
U F
U F
STM
S T
M
STM
S T
M
S T
M
S T
M
STM
STM
STM
STM
SAN
SAN
SAN
SAN
W
W
W
W
AREA 101AREA 102
AREA 103AREA 104AREA 105AREA 106AREA 107
AREA 108AREA 109
AREA 110
AREA 111
AREA 112
AREA 113
AREA 161AREA 162AREA 163
KEY PLAN
PLAN
NORTH
AREA 114
GENERAL NOTES:
1. CONTRACTOR TO COORDINATE DEMOLITION OF CATV
INFRASTRUCTURE WITH COX COMMUNICATIONS PRIOR TO
DEMOLITION OF PIER.
2. ALL ELECTRICAL INFRASTRUCTURE IN SHADED AREA NOT NOTED
ABOVE IS TO BE DEMOLISHED. COORDINATE SALVAGE/RETURN OF
ELECTRICAL EQUIPMENT WITH GOVERNMENT.
3. REFER TO CABLE AND CONDUIT SCHEDULE ON SHEET EP701 FOR
CABLE DESCRIPTION.
4. COORDINATE DEMOLITION WORK WITH PROJECT PHASING PLAN.
REFER TO SHEETS G-121 THROUGH G-128 FOR ADDITIONAL
INFORMATION.
5. AS INDICATED ON EXISTING PIER 3 DEMOLITION DRAWINGS, REMOVE
AND TURN OVER TO THE GOVERNMENT SIX-(6) 4MVA UNIT
SKID-MOUNTED SUBSTATIONS, TWO-(2) 500KVA INDUSTRIAL POWER
PAD-MOUNTED TRANSFORMERS, AND FOUR-(4) 600V-800A INDUSTRIAL
POWER STATIONS (IPS). THE CONTRACTOR IS RESPONSIBLE TO
DELIVER THE DEMOLISHED AND REMOVED EQUIPMENT TO A
DESIGNATED STORAGE LOCATION BY THE GOVERNMENT. THE
CONTRACTOR IS RESPONSIBLE TO HANDLE WITH CARE ALL REMOVED
EQUIPMENT, SO THAT THE UNIT SUBSTATIONS SECONDARY
BUSHINGS ARE NOT BEING BROKEN OR DAMAGED DURING THE
REMOVAL OFF THE PIER AND DELIVERING TO THE STORAGE
LOCATION. THE POC TO COORDINATE THE DELIVERING OF THE
EQUIPMENT REMOVED FROM PIER 3 IS MR. MARVIN VAUGHN,
MARVIN.VAUGHN2@NAVY.MIL, 757-341-0743.
AutoCAD SHX Text
DMITRI ZAICHENKO
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .