1614696dwg17of22_FIRE-BUILD.pdf

PDF 771 KB Posted

Attached to
P-095 Pier 3 Recap Naval Station Norfolk, VA
Solicitation number
N4008521R0219
Issued by

About this file

This document package includes construction drawings and specifications for fire protection systems upgrades at a Navy utility building. The drawings show proposed fire alarm and suppression systems, including device locations, riser diagrams, and design criteria. The fire alarm system will provide audible and visual notification, with smoke detectors, pull stations, strobes, and horns. The wet-pipe sprinkler system will cover the building using sprinkler heads, piping, a fire pump, and jockey pump. The Navy seeks bids for installation of these fire protection upgrades per the specifications in the solicitation N4008521R0219 for work at Naval Station Norfolk in Virginia. Submissions are due by the date specified in the solicitation to the Naval Facilities Engineering Command.

View the file

Other files

File Type Posted
Amendment 0010 and 0011.pdf PDF
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
MIL-STD-767 REV G.pdf PDF
Amendment 0007.pdf PDF
1614696Amend0006dwg 1of1.pdf PDF
Attachment K- PIEE Vendor Access Instructions.pdf PDF
1614696Amend0006spc 1of1.pdf PDF
Amendment 0006.pdf PDF
Pier 3 Contractor Laydown Map.pdf PDF
Attachment H - Price Proposal Form Revised 3.docx DOCX document
Amendment 0005.pdf PDF
Attachment G - Small Business Subcontracting Plan Template Revised.pdf PDF
Amendment 0004.pdf PDF
1614696Amend0004dwg 1of1.pdf PDF
Composite Camel Reference Drawings.pdf PDF
Attachment C - Construction and Design Experience Project Data Sheet.docx DOCX document
Attachment H - Price Proposal Form Revised 2.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
P095 Site Visit Log.pdf PDF
Attachment H-Price Proposal Form Revised.docx DOCX document
Amendment 0001.pdf PDF
1614696dwg15of22_ARCH-BUILD.pdf PDF
Attachment E - Historical SB Utilization.docx DOCX document
1614696spc05of19_APP-A4.pdf PDF
1614696Amend0001dwg 2of4.pdf PDF
1614696dwg11of22_STRUCT-PIER.pdf PDF
1614696spc11of19_APP-B3.pdf PDF
1614696dwg20of22_ELEC-BUILD.pdf PDF
1614696spc10of19_APP-B2.pdf PDF
1614696spc17of19_APP-E.pdf PDF
Attachment A - PPI Log.doc DOC document
1614696dwg04of22_GEOTECH.pdf PDF
Attachment G - Small Business Subcontracting Plan Template.doc DOC document
1614696dwg13of22_MECH-PIER.pdf PDF
1614696dwg06of22_CIVIL-SITE.pdf PDF
1614696spc16of19_APP-D.pdf PDF
Attachment D - Past Performance Questionnaire.docx DOCX document
1614696spc02of19_APP-A1.pdf PDF
Attachment I - ODP Badge Access Request.xls XLS spreadsheet
1614696dwg22of22_CAT_PROTECT.pdf PDF
1614696spc15of19_APP-C.pdf PDF
1614696dwg14of22_ELEC-PIER.pdf PDF
1614696Amend0001dwg 4of4.pdf PDF
1614696dwg10of22_STRUCT-PIER.pdf PDF
1614696spc06of19_APP-A5.pdf PDF
1614696spc01of19.pdf PDF
Attachment B - SECNAV 5512.pdf PDF
1614696dwg12of22_FIRE-PIER.pdf PDF
Show 40 more

Latest 50 of 79 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE ALARM SYSTEM LEGEND GENERAL NOTES:ABBREVIATIONS:

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AWG AMERICAN WIRE GAUGE

CD CANDELA

CFM CUBIC FEET PER MINUTE

CIS COMMON INTELLIGIBILITY SCALE

CO CARBON MONOXIDE

DB DECIBEL

DBA DECIBEL A-WEIGHTED

DDC DIRECT DIGITAL CONTROL

EMCS ENERGY MONITORING AND CONTROL SYSTEM

FA FIRE ALARM

FDC FIRE DEPARTMENT CONNECTION

FM FM GLOBAL

IAW IN ACCORDANCE WITH

IDC INITIATING DEVICE CIRCUIT

NAC NOTIFICATION APPLIANCE CIRCUIT

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NC NORMALLY CLOSED

NO NORMALLY OPEN

RF RADIO FREQUENCY

SLC SIGNALING LINE CIRCUIT

TYP TYPICAL

UL UNDERWRITERS LABORATORY

WP WEATHERPROOF (NEMA 250, TYPE 3R)

S P

PHOTOELECTRIC SMOKE DETECTOR

WF WATER FLOW DETECTOR / SWITCH (PROVIDED BY DIVISION 21)

FPC FIRE PUMP CONTROLLER (PROVIDED BY DIVISION 21)

FACU FIRE ALARM CONTROL UNIT

VS VALVE SUPERVISORY SWITCH (PROVIDED BY DIVISION 21)

SS SURGE SUPPRESSOR (TRANSIENT VOLTAGE SURGE SUPPRESSOR)

HORN / STROBE COMBINATION

AOM ADDRESSABLE OUTPUT CONTROL MODULE

AIM ADDRESSABLE INPUT MONITOR MODULE

BATT SECONDARY POWER SUPPLY (BATTERY)

GROUND

1. PROVIDE AN ADDRESSABLE FIRE ALARM SYSTEM AS INDICATED ON THE DRAWINGS.

NOTIFICATION SYSTEM MUST BE CAPABLE OF PROVIDING 3 TEMPORAL OR 4 TEMPORAL

EVACUATION SIGNAL DEPENDING ON THE ALARM.

2. COORDINATE ALL REQUIRED SYSTEMS TO THE SATISFACTION OF THE ENGINEER AND

AUTHORITY HAVING JURISDICTION. ANY DEFICIENCIES, INCONSISTENCIES, OR POORLY

COORDINATED INSTALLATIONS MUST BE CORRECTED BY THE CONTRACTOR AT NO

ADDITIONAL COST.

3. THE FIRE ALARM DRAWINGS ARE SCHEMATIC IN NATURE AND SHOW A MINIMAL QUANTITY OF

DEVICES. DETERMINE THE FINAL QUANTITY AND LOCATION OF ALL DEVICES IN ACCORDANCE

WITH THE SPECIFICATIONS, CONTRACT DRAWINGS, AND MANUFACTURER'S WRITTEN

RECOMMENDATIONS TO BE COMPLIANT WITH ALL APPLICABLE CODES AND STANDARDS.

PROVIDE ADDITIONAL DEVICES WHEN REQUIRED FOR A FULLY FUNCTIONING FIRE ALARM

SYSTEM AS REQUIRED BY NFPA 72.

4. SURFACE MOUNT CONDUITS TO WALLS AND CEILINGS THROUGHOUT THE BUILDING. WHERE

A CONDUIT SUPPLIES A DEVICE NOT MOUNTED DIRECTLY ON THE WALL OR CEILING, ROUTE

THE CONDUIT AS A SINGLE PENDENT DROP TO EACH DEVICE FROM THE CEILING SURFACE

ABOVE. DO NOT TRAPEZE CONDUIT ACROSS AN OPEN SPACE.

5. ALL FIRE ALARM JUNCTION BOXES, COVERS AND CONDUITS IN UNFINISHED AREAS ARE TO

BE PROVIDED PRE-FINISHED RED FROM THE FACTORY. PAINT EXPOSED CONDUIT AND

JUNCTION BOXES IN FINISHED AREAS TO MATCH ADJACENT SURFACES WITH JUNCTION

BOXES INSIDE COVER LABELED, "FIRE ALARM", AND WHERE CONDUIT PENETRATES A WALL,

PAINT RED 3/4 INCH BANDS EVERY 20 FT AND BOTH SIDES OF PENETRATIONS.

6. PROVIDE CONDUIT IN ACCORDANCE WITH THE REQUIREMENTS OF THE ELECTRICAL

SPECIFICATIONS, UNLESS OTHERWISE NOTED. SUPPORT CONDUIT IN ACCORDANCE WITH

THE NEC SUCH AS MAXIMUM 10 FT SUPPORT INTERVALS AND 3 FT FROM A TERMINATION.

TENSION ONLY HANGERS ARE NOT PERMITTED SUCH AS BATWINGS. FLEXIBLE CONDUIT IS

ONLY PERMITTED WHEN CONNECTING TO THE FOLLOWING DEVICES AND APPLIANCES:

DEVICES LOCATED ON FIRE SUPPRESSION EQUIPMENT SUCH AS FLOW/PRESSURE

SWITCHES AND TAMPER SWITCHES, DEVICES AND APPLIANCES LOCATED IN REMOVABLE

CEILING TILES, OR WHERE SPECIFICALLY NOTED.

7. PROVIDE CONDUCTOR SIZING NOT LESS THAN 18 AWG FOR SLC. PROVIDE CONDUCTOR

SIZING NOT LESS THAN 16 AWG FOR NAC, AND IDC. CONSISTENTLY COLOR COORDINATE ALL

CONDUCTORS THROUGH THE SYSTEM IN RELATION TO DEVICES THEY FEED SUCH AS SLC -

BLACK/RED, STROBE - YELLOW/BLUE. PROVIDE ADDRESSABLE SLC CIRCUITS WITH SHIELDED

CONDUCTORS, WHERE THE SHIELDING IS GROUNDED AT ONE END WHERE REQUIRED BY

THE MANUFACTURER. PROVIDE ALL CIRCUITS WITH LAVELING AT THE POINT OF

TERMINATION SUCH AS SLC 1, NAC 8, IDC 4.

8. RUN CONDUCTORS FROM DEVICE TO DEVICE WITHOUT SPLICES. WIRE NUTS ARE

PROHIBITED. UTILIZE TERMINAL STRIPS WHERE CONDUCTORS CANNOT BE DIRECTLY

TERMINATED AT THE DEVICE SUCH AS PIGTAILS OFF A HEAT DETECTOR.

9. DO NOT USE FIRE ALARM EQUIPMENT PANELS AS RACEWAY FOR ROUTING POWER WIRING

OR LOW VOLTAGE WIRING. ONLY ROUTE WIRING TERMINATING WITHIN THE PANEL INTO THE

PANEL. PROVIDE 1/4 INCH SEPARATION BETWEEN POWER-LIMITED FIRE ALARM CIRCUITS

AND POWER CIRCUITS.

10. MOUNTING DEVICES IN THE FACU, INCLUDING ANY SUBPANELS SUCH AS NAC AND FAC,

WHICH ARE NOT UL LISTED OR FM APPROVED AS PART OF THE UNIT IS PROHIBITED.

11. PROVIDE SURGE SUPPRESSORS TO PROTECT ALL POWER SUPPLY CIRCUITS TO THE FACU,

INCLUDING ANY SUBPANELS SUCH AS NAC, FAC, AND ALL FIRE ALARM CIRCUITS LEAVING OR

ENTERING THE BUILDING. DEVICES AND APPLIANCES MOUNTED DIRECTLY ON THE EXTERIOR

OF THE BUILDING SUCH AS WALL MOUNTED EXTERIOR HORN STROBES DO NOT REQUIRE

SUPPRESSORS. MOUNT SURGE SUPPRESSORS IN A SEPARATE ENCLOSURE, UNLESS IT IS UL

LISTED OR FM APPROVED AND INSTALLED IN THE CONTROL UNIT BY THE FACTORY.

12. INSTALL FIRE ALARM BATTERIES IN THE ENCLOSURE OF THE DEVICE/UNIT IT SUPPORTS

SUCH AS FACU ENCLOSURE OR IN AN INDEPENDENT DEDICATED ENCLOSURE.

13. EXTERIOR SIGNAGE MUST COMPLY WITH SPECIFICATION 10 14 00.10.

ROOM TAG

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL TAG

ROOM NAME

ROOM NUMBER

? INTERIOR ELEVATION

TAG

INTERIOR ELEVATION NUMBER

SHEET WHERE DRAWN

DETAIL NUMBER

SCALE

SHEET

REFERENCED

FROM

EXTERIOR ELEVATION

TAG

ELEVATION NUMBER

DIRECTION OF VIEW

SHEET WHERE DRAWN

WALL / PARTIAL

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

GENERAL PROJECT SYMBOLS

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

BUILDING

NEW WORK

KEYNOTE TAG

KEYNOTE NUMBER

PLAN

NORTH

SCALE

TRUE NORTH

SHEET

REFERENCED

FROM

F MANUAL FIRE ALARM PULL STATION

F AUDIBLE DEVICE

H = HORNH

STROBE

WALL MOUNT STROBE

WALL MOUNTED CARBON MONOXIDE DETECTOR

W

NAC NOTIFICATION CIRCUIT POWER BOOSTER, EXTENDER PANEL

FAC FIRE ALARM TRANSMITTER

AUDIBLE DESIGN CRITERIA:

VISIBLE DESIGN CRITERIA:

1. PROVIDE AUDIBLE NOTIFICATION APPLIANCES AS INDICATED TO ACCOMPLISH THE FOLLOWING

DESIGN CRITERIA WITH ALL DOORS, FIRE SHUTTERS, AND WINDOWS CLOSED. WHERE THIS

DESIGN CRITERIA IS NOT ACCOMPLISHED DURING ACCEPTANCE TESTING, PROVIDE

ADDITIONAL DEVICES TO MEET THE MINIMUM DESIGN CRITERIA WITHOUT EXCEEDING THE

LIMITATIONS OF THE FACU, OR NAC (INCLUSIVE OF PRESCRIBED SAFETY FACTORS).

2. PROVIDE A QUANTITY OF HORNS IN EACH ROOM/AREA TO ACHIEVE THE REQUIRED SOUND

POWER OUTLINED IN THESE CONTRACT DOCUMENTS.

3. PROVIDE A MINIMUM SOUND POWER OF 70 DBA AND 15 DBA OVER THE AVERAGE AMBIENT

SOUND LEVEL OR 5 DBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST

60 SECONDS, WHICHEVER IS GREATER, AT THE MOST REMOTE LOCATION WITHIN THE

ROOM/AREA MEASURED AT 5 FT AFF. MEASURE THE SOUND POWER OFF THE TEMPORAL

THREE TONE PATTERN.

4. THE FOLLOWING CRITERIA WILL BE USED FOR REVIEW AND APPROVAL OF SHOP DRAWINGS.

A. REDUCE THE SOUND POWER BY 6 DB EACH TIME THE DISTANCE BETWEEN THE

APPLIANCE AND THE LISTENER IS DOUBLED. STARTING DISTANCE IS PER

MANUFACTURER'S DATASHEET, TYPICALLY 10 FT.

B. REDUCE THE SOUND POWER IN ACCORDANCE WITH THE MANUFACTURER'S DATASHEET

FOR SOUND POWER DISTRIBUTION NOT PERPENDICULAR TO THE FACE OF THE

APPLIANCE. REFER TO MANUFACTURER'S TYPICAL SOUND OUTPUT DISTRIBUTION

DIAGRAM.

C. IN LIEU OF THE MANUFACTURER'S PUBLISHED DB LOSS, ASSUME A MINIMUM 15 DB LOSS

THROUGH A STANDARD CLOSED DOOR.

1. PROVIDE VISIBLE NOTIFICATION APPLIANCES TO ACHIEVE THE COVERAGE INDICATED.

2. SPACE STROBES IN ACCORDANCE WITH THE CRITERIA OUTLINED IN NFPA 72, UNLESS

OTHERWISE NOTED.

CO

JPC JOCKEY PUMP CONTROLLER (PROVIDED BY DIVISION 21)

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

L K

N

O R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

DSN

JAMES E. DONAHUE, R.A.

/1

/2

:4 :4

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-F

-U S

B D h jc h o .r v t

AF001

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

F

IR

E A

LA

R

M N

O

TE

S , L

E G

E N

D A

N D

A B

B R

E V

IA

T

IO

N

S

AJS

12829415

KMK KPZ

1614696

ANDREW P. LEAHY

M C O M O N

W

EA

LTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No.058278P R

E R

UP UP

NOTIFICATION APPLIANCES ARE NOT REQUIRED.

FIRE ALARM HATCH LEGEND

NO HATCH

PROVIDE CEILING AND/OR WALL MOUNTED HORNS AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

PROVIDE CEILING AND/OR WALL MOUNTED HORNS AND CLEAR

STROBES AS REQUIRED TO ACHIEVE DESIGN CRITERIA.

FRESH WATER

PUMP ROOM

USB2

PURE WATER

ROOM

USB3

MEDIUM

PRESSURE AIR

ROOM

USB4

HIGH PRESSURE

AIR ROOM

USB5

TELECOM ROOM

USB8

MAIN ELECTRICAL

ROOM

USB6

GENERATOR

ROOM

USB7

EQUIPMENT YARD

USB0

FIRE PUMP

USB1

WP

1 2 3 4 5 6 7

A

B

C

D

VS

WF

FPC-2

F

F F F F F F F F

F

W

F

CO

FPC-1

JPC-1

JPC-2

FACU

FAC

S P

NAC 4

FIRE ALARM

CLOSET

USB9

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

DSN

JAMES E. DONAHUE, R.A.

/1

/2

:4 :4

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-F

-U S

B D h jc h o .r v t

AF100

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

F

IR

E A

LA

R

M P

LA

N

AJS

12829416

KMK KPZ

1614696

GENERAL NOTES

1. REFER TO AF001 FOR GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS

AND SYMBOLS.

WORK NOTES

1/16" = 1'-0" A1

USB - FIRE ALARM PLAN

PLAN

NORTH

8' 16' 32'0'

X

1. OUTDOOR COOLING TOWER YARD.

2. PROVIDE WP HORN/STROBE ABOVE FDC. REFER TO SHEET AF501, DETAIL

A4 FOR HORN/STROBE AND SIGNAGE REQUIREMENTS.

3. MONITOR WATERFLOW SWITCHES AND TAMPER SWITCHES. COORDINATE

QUANTITY AND LOCATION WITH FIRE SUPPRESSION CONTRACTOR.

4. QUANTITY BY CONTRACTOR'S DESIGN TO MEET DESIGN CRITERIA.

ANDREW P. LEAHY

M C O M O N

W

EA

LTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No.058278P R

5 FT (MIN)

12 INCHES

(MAX)

WALL MOUNTED SMOKE

DETECTOR

CEILING MOUNTED

SMOKE DETECTOR

SUPPLY OR

RETURN

DIFFUSER

CEILING

FINISHED FLOOR

BATT

FACU

ROUTE CONDUIT TO ACHIEVE

SEPARATION OF POWER-LIMITED FIRE

ALARM CIRCUITS AND POWER CIRCUITS

IN

S

T A

LL

N

O G

R E

A T

E R

T H

A N

IN

C

H E

S A

F F

FAC

SS SS

BATT

F

MINIMUM 12 INCHES

FROM LIGHT SWITCH

48 INCHES

MAX

PULL STATIONS SHALL NOT BE

LOCATED BEHIND DOOR SWINGS.

TO EXIT DOOR

5 FT (MAX)

FOR CEILING HEIGHTS LESS THAN 96

INCHES THE VISIBLE LENS MOUNTING

HEIGHT MUST BE WITHIN 6 INCHES OF

THE CEILING

SYNCHRONIZE TWO OR

MORE APPLIANCES IN ANY

FIELD OF VIEW

IN

C H

E S

WALL

MOUNTED

VISIBLE

APPLIANCE

CEILING MOUNTED

VISIBLE APPLIANCE

AUDIBLE

ONLY WALL

MOUNTED

APPLIANCE

CARBON

MONOXIDE

DETECTOR

72 INCHES TO

TOP

BATT

NAC

FACU

S P

VS WF

AIM

FPC

SS

3 4

POWER CIRCUIT

NOTIFICATION APPLIANCE CIRCUIT

(CLASS B)

SIGNALING LINE CIRCUIT (CLASS B)

AIMAIM

120 VAC 1

BATT

CIRCUIT LEGEND

AOM

OCCUPANCY

SENSOR

INITIATING DEVICE CIRCUITS (CLASS B)

1. RED, LOCKABLE BREAKER LABELED "FIRE ALARM" PROVIDED BY DIVISION

26. SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.

2. REFER TO FIRE SUPPRESSION DRAWINGS FOR QUANTITY AND / OR

LOCATIONS OF DEVICE(S).

3. REFER TO FIRE ALARM PLANS FOR QUANTITY AND / OR LOCATIONS OF

DEVICE(S).

4. PROVIDE ADDRESSABLE INPUT AND/OR OUTPUT MODULE(S) AS

REQUIRED TO ACHIEVE THE FUNCTIONALITY INDICATED IN THE FIRE

ALARM MATRIX.

5. EXTERIOR WP HORN STROBE OVER FDC.

6. EGRESS LIGHTING TO ACTIVATE UPON ACTIVATION OF FIRE ALARM.

VERIFY CONDITION WITH NFPA 101.

7. DIGITIZE DET-16 TELEGRAPH TRANSMITTER.

8. QUANTITY AND LOCATION BY CONTRACTOR'S DESIGN TO MEET DESIGN

CRITERIA.

9. PROVIDE ADDTIONAL BOOSTER PANELS AS REQUIRED PER

CONTRACTOR'S DESIGN. WHERE ADDITIONAL BOOSTER PANELS ARE

REQUIRED LOCATE AS INDICATED ON PLAN.

10. TO BASE FIRE ALARM TELEGRAPHIC LOOP. REFER TO SHEETS ET109 AND

ET701 FOR TIE-IN LOCATION AND DETAILS.

11. 24 VDC FROM FACU OR NAC PANEL.

AIM

TO GENERATOR

CONTROLLER

4 4

F

BATT

SS

120 VAC

NAC

AOM

AIM

SYNCHRONIZATION CIRCUIT TO

NEXT NAC PANEL

F

WP

H

W

FAC

BATT SS

120 VAC 1

AOM

AIM

4 4

CO

FIRE ALARM CONTROL UNIT (FACU) FUNCTIONAL MATRIX

ANNUNCIATION AT

LOCAL PANEL

NOTIFICATION AUX.

FUNC.

A U

D

IO

-V

IS

IB

LE

F

IR

E A

LA

R

M

IN

D

IC

A T

IO

N

B Y

D

V

IC

E

A U

D

IO

-V

IS

IB

LE

T R

O U

B

LE

IN

D

IC

A

T

IO

N

V

IC

E

A U

D

IO

-V

IS

IB

LE

S U

P E

R V

IS

O

R Y

IN

D

IC

A

T

IO

N

V

IC

E

C O

M M

O N

T R

O U

B

LE

S

IG

N A

L T

O F

IR

P

A R

T M

E N

T

C O

M M

O N

S U

P E

R V

IS

O

R Y

S

IG

N A

L T

O F

P

A R

T M

E N

T

ALARM SIGNALS

SMOKE DETECTOR OVER FACU

FLOW SWITCH - UTILITY BUILDING WET-PIPE SYSTEM

AC POWER FAILURE

LOW BATTERY

OPEN CIRCUIT FAULT

GROUND FAULT

NOTIFICATION APPLIANCE CIRCUIT SHORT

TROUBLE SIGNALS

COMPONENT COMMON TROUBLE

SUPERVISORY SIGNALS

COMPONENT COMMON SUPERVISORY

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

FIRE PUMP RUNNING

FIRE PUMP CONTROLLER SUPERVISORY X X

FIRE PUMP POWER/PHASE FAILURE

FIRE PUMP PHASE REVERSAL

GENERAL VALVE SUPERVISORY X X

T U

R N

O N

E G

R E

S S

L

IG

H T

IN

G

X

X

S M

O K

E D

E T

E C

T

IO

N A

LA

R

M S

IG

N

A L

T O

F

IR

E D

E P

A R

T M

E

T

X

F

IR

E S

U P

P R

E S

S

IO

N A

C T

IV

A

T

IO

N A

LA

R

M S

IG

N

A L

E

D E

P A

R T

M E

E P

U M

P R

U N

N

IN

G A

LA

R

M S

IG

N

A L

T O

F

IR

E D

E P

A R

T M

E

X

X X

X X

X X

A C

T

IV

A T

E W

E A

T H

E R

P R

O

H

R N

/S T

R O

B E

A B

O V

E F

D C

X

GENERATOR RUNNING X

X

X

XGENERATOR FAULT

GENERATOR SWITCH IN NONAUTOMATIC POSITON X X

FIRE PUMP CONTROLLER LOW TEMPERATURE SIGNAL X X

MANUAL FIRE ALARM STATIONS X

M A

N U

A L

P U

LL

S

T A

T

IO

N A

LA

R

M S

IG

N

A L

T O

F

P A

R T

M E

X X

CARBON MONOXIDE DETECTOR

C A

R B

O N

M O

N O

X

ID

E A

LA

R

M S

IG

N

A L

E

D E

P A

R T

M E

A U

D

IB

LE

N

O T

IF

IC

A T

IO

N

C A

R B

O N

M O

N O

X

ID

M P

O R

A L

P

A T

T E

R N

X X

F

IR

E A

LA

R

M V

IS

IB

LE

A

N D

A U

D

IB

LE

N

O T

IF

IC

A T

IO

N

X

X

X

X X

FAC TROUBLE

X X

FIRE PUMP RUNNING

WHEN FLASHING

MINIMUM 3 INCH HIGH RED LETTERING (TYP)

WEATHERPROOF 135 CANDELA RED-LENS

HORN-STROBE (NO LETTERING ON CASE)

MOUNTED OVER SIGN (FACE OF BACKBOX TO

BE FLUSH WITH SIGN SURFACE)

WHITE REFLECTIVE BACKGROUND ON ALUM

SIGN BLANK

1/2 INCH MIN. WIDE RED BORDER

LEAVE BOTTOM 4 INCH BLANK FOR

FUTURE CUSTOMIZATION

MINIMUM 18 INCH

M

IN

IM

U

M

IN

C H

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

DSN

JAMES E. DONAHUE, R.A.

/1

/2

:4 :4

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-F

-U S

B D h jc h o .r v t

AF501

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

F

IR

E A

LA

R

M D

E T

A

IL

S , F

IR

E

A

LA

R M

O N

E -L

IN

E

D

IA

G R

A M

, A N

D F

IR

E

A

LA

R M

M A

TR

IX

AJS

12829417

KMK KPZ

1614696

NOT TO SCALE

A1

TYPICAL MOUNTING DETAIL

GENERAL NOTES

1. REFER TO AF001 FOR GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS

AND SYMBOLS.

2. THE FIRE ALARM RISER SHOWS THE INTENT OF THE FIRE ALARM

INFRASTRUCTURE. NOT ALL DEVICES ARE SHOWN. CONTRACTOR MUST

PROVIDE THE QUANTITY OF DEVICES AS REQUIRED TO COMPLY WITH

NFPA 72, AND CONTRACT DOCUMENTS.

3. EACH FLOW AND TAMPER SWITCH MUST REPORT BACK TO THE FIRE

ALARM CONTROL UNIT WITH A SEPARATE ADDRESS. GROUPED SWITCHES

ON ONE ADDRESS ARE NOT ACCEPTABLE.

NOT TO SCALE

B3

FIRE ALARM RISER

WORK NOTES X

NOT TO SCALE

A4

FIRE PUMP RUNNING INDICATOR

ANDREW P. LEAHY

M C O M O N

W

EA

LTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No.058278P R

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AS AUTOMATIC SPRINKLER

FM FM GLOBAL

FP FIRE PUMP

FPPS FREEZE PROTECTION PUMP SKID

HSCP HORIZONTAL, SPLIT-CASE

JP JOCKEY PUMP

(M) MECHANICALLY SUPERVISED

MSC MULTI-STAGE CENTRIFUGAL

NC NORMALLY CLOSED

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NO NORMALLY OPEN

NO(M) NORMALLY OPEN, MECHANICAL SUPERVISION

RN RISER NIPPLE

RPZ REDUCED PRESSURE ZONE

(S) ELECTRICALLY SUPERVISED

SPR SPRINKLER PIPE

SQ FT SQUARE FOOT

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

VMSC VERTICAL MULTI-STAGE CENTRIFUGAL

FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA

PRESSURE RELIEF VALVE

OUTSIDE SCREW AND YOKE VALVE

(OS&Y)

VALVE

ANGLE VALVE

BACKFLOW PREVENTER RPZ TYPE

INDICATING BUTTERFLY VALVE

FLOW TEST HEADER

CHECK VALVE

PIPE CAP

AUTOMATIC DRAIN VALVE

PRESSURE GAUGE

SIGHT GLASS

FLOW SWITCH

FIRE SUPPRESSION LEGEND FIRE SUPPRESSION ABBREVIATIONS FIRE SUPPRESSION DESIGN CRITERIA FIRE SUPPRESSION GENERAL NOTES

DRAIN PIPING

PIPING SYMBOLS

THRUST BLOCK

AUTOMATIC AIR RELEASE VALVE

FIRE PUMP

JOCKEY PUMP

F

J

RISER LOCATION

HAZARD CLASSIFICATIONMARK

WET

SYSTEM

TYPE

WET

REMOTE

AREA

SQ FT

HOSE DEMAND

GPM

TEMP RATING

(ºF)

TYPE

(CEILINGS)

HIGH TEMPERATURE

INTERMEDIATE

TEMPERATURE

STANDARD RESPONSE CHROME

RECESSED PENDENT

STANDARD RESPONSE BRASS

UPRIGHT

0.30

DENSITY

GPM/SF

0.20

MAXIMUM AREA PER

HEAD

SQ FT

EXTRA HAZARD (CEILING 30 FT

OR LESS AFF)

ORDINARY HAZARD (CEILING

30 FT OR LESS AFF)

ADDITIONAL CODE

REFERENCE

SPRINKLER CHARACTERISTICS

MINIMUM

K-FACTOR

11.2

8.0

FIRE SUPPRESSION SYSTEM

WET SYSTEM

ELBOW UP OR DOWN

TEE UP OR DOWN

SYSTEM PIPING

1. SERVE THE FIRE SUPPRESSION SYSTEM FROM THE EXISTING DOMESTIC

SYSTEM AND PROJECT'S FIRE BOOSTER PUMP SYSTEM. PERFORM A

HYDRANT FLOW TEST, AND INCORPORATE THIS TEST INTO THE

HYDRAULIC CALCULATIONS. HYDRANT FLOW TESTING MUST BE IN

ACCORDANCE WITH NFPA 291, AND THE RESULTS OF THE TESTING MUST

BE SUBMITTED AS INDICATED IN NFPA 291 FIGURE 4.11.2.

FOR INFORMATION ONLY: FLOW TEST 1. REFER TO SHEET FX001 FOR IMAGE

SHOWING LOCATIONS OF GAUGE AND FLOW

HYDRANTS.

DATE 11/21/2019

TIME 1101

STATIC 70 PSI

RESIDUAL 48 PSI

FLOW 965 GPM

2. THE FIRE SUPPRESSION SYSTEM MUST BE DESIGNED AND INSTALLED BY

A LICENSED / CERTIFIED COMPANY WHERE EMPLOYEES ARE LICENSED /

CERTIFIED TO INSTALL FIRE PROTECTION EQUIPMENT IN THE

COMMONWEALTH OF VIRGINIA.

3. ALL COMPONENTS AND ASSEMBLIES USED IN THIS FIRE PROTECTION

SYSTEM MUST BE SPECIFICALLY UL LISTED OR FM APPROVED FOR

THEIR INTENDED USE.

4. USE SCHEDULE 40 BLACK STEEL FIRE WATER PIPING FOR SIZES 2 INCH

AND SMALLER WITHIN THE UTLITY BUILDING. FOR PIPING 2-1/2 INCH AND

LARGER, USE SCHEDULE 10 BLACK STEEL FIRE WATER PIPING WITHIN

THE UTILITY BUILDING. PROVIDE PIPING MATERIAL SUITABLE FOR USE IN

POTABLE WATER SYSTEMS IN COMPLIANCE WITH THE INTERNATIONAL

PLUMBING CODE AND LOCAL JURISDICTION UPSTREAM OF THE

BACKFLOW PREVENTER.

1. PROVIDE ALL NECESSARY COMPONENTS FOR A WET-PIPE SYSTEM IN THE

UTILITY BUILDING. AT A MINIMUM PROVIDE COMPONENTS AS INDICATED

ON THESE DRAWINGS. PROVIDE ADDITIONAL COMPONENTS AND

MODIFICATIONS AS REQUIRED TO PROVIDE A FULLY FUNCTIONING FIRE

SUPPRESSION SYSTEM.

2. COORDINATE ALL REQUIRED SYSTEMS TO THE SATISFACTION OF THE

ENGINEER AND AUTHORITY HAVING JURISDICTION. CORRECT ANY

DEFICIENCIES, INCONSISTENCIES, OR POORLY COORDINATED

INSTALLATIONS AT NO ADDITIONAL COST.

3. FINAL DESIGN REQUIREMENTS (DEVICE QUANTITY, SIZE, AND LOCATIONS)

ARE THE SOLE RESPONSIBILITY OF THE FIRE SUPPRESSION

CONTRACTOR. DRAWINGS INDICATE MINIMUM REQUIREMENTS; VERIFY

AND COORDINATE FINAL DESIGN REQUIREMENTS WITH THESE

CONSTRUCTION DOCUMENTS, SPECIFICATIONS, REFERENCE

DOCUMENTS, APPLICABLE CODES, AND FACILITY USER REQUIREMENTS.

4. INSTALL FIRE PROTECTION PIPE HANGERS PER THE FOLLOWING

LIMITATIONS:

A. THE SINGLE POINT DEAD LOAD APPLIED TO ANY STRUCTURAL

MEMBER MUST NOT EXCEED 300 LBS. PROVIDE TRAPEZE HANGERS

TO DISTRIBUTE THE LOAD BETWEEN STRUCTURAL MEMBERS

WHERE A SINGLE HANGER EXCEEDS THE LIMITATIONS.

5. ALL VALVES INCLUDING CONTROL AND TRIM VALVES MUST BE WITHIN

6'-0" AFF UNO.

6. PRESSURE RATINGS OF VALVES, FITTINGS, COUPLINGS, AND ALL OTHER

COMPONENTS MUST MEET OR EXCEED THE ACTUAL PRESSURES TO

WHICH THOSE COMPONENTS ARE SUBJECTED.

7. EXTERIOR SIGNAGE MUST COMPLY WITH SPECIFICATION 10 14 00.10.

TYPE

(EXPOSED)

QUICK RESPONSE BRASS

UPRIGHT

QUICK RESPONSE CHROME

RECESSED PENDENT

FPC

JPC

ROOM TAG

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL TAG

ROOM NAME

ROOM NUMBER

? INTERIOR ELEVATION

TAG

INTERIOR ELEVATION NUMBER

SHEET WHERE DRAWN

DETAIL NUMBER

SCALE

SHEET

REFERENCED

FROM

EXTERIOR ELEVATION

TAG

ELEVATION NUMBER

DIRECTION OF VIEW

SHEET WHERE DRAWN

WALL / PARTIAL

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

GENERAL PROJECT SYMBOLS

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

BUILDING

NEW WORK

KEYNOTE TAG

KEYNOTE NUMBER

PLAN

NORTH

SCALE

TRUE NORTH

SHEET

REFERENCED

FROM

FIRE PUMP CONTROLLER

JOCKEY PUMP CONTROLLER

NFPA 37, 11.4.5

5 INCH STORZ TYPE FIRE DEPARTMENT

CONNECTION

FPPS FREEZE PROTECTION PUMP SKID

WM WATER METER

UFC 3-600-01, TABLE 9-3

FIRE DEPARTMENT CONNECTION - WITH TWO

2-1/2 INCH INLETS

PUMP SCHEDULE

PUMP

TYPE

F-1

MARK

ELECTRICAL DATA

HSCP

DRIVE TYPE

ELECTRIC

SERVICE

TYPE

FLOW RATE

(GPM)

RATED

PRESSURE

(PSI)

MAXIMUM PUMP

SPEED

(RPM) HP V/Ph/Hz

FIRE PUMP

JOCKEY PUMP

750 95 1770 75 460/3/60

J-1 MSC ELECTRIC 5 95 3500 3 460/3/60

F-2 HSCP ELECTRIC REDUNDANT

FIRE PUMP

750 95 1770 75 460/3/60

REDUNDANT

JOCKEY PUMP

J-2 MSC ELECTRIC 5 95 3500 3 460/3/60

FPPS VMSC ELECTRIC

FREEZE

PROTECTION

PUMP

400* 95

*PUMP SKID IS COMPRISED OF TWO PRIMARY PUMPS EACH RATED AT 200 GPM WITH ONE REDUNDANT PUMP RATED AT 200

GPM. RATED PRESSURE MUST BE 95 PSI.

3 AT 203600 460/3/60

BACKFLOW PREVENTER SCHEDULE

LOCATION

FPBFP-1

MARK

FIRE PUMP USB 1

SIZE

MINIMUM PRESSURE

DROP (PSI) TYPE

12 RPZ8 INCH

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

DSN

JAMES E. DONAHUE, R.A.

/1

/2

:4 :4

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-F

-U S

B D h jc h o .r v t

AX001

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

F

IR

E S

U P

P R

E S

S

IO

N N

O T

E S

, L E

G E

N D

A N

D A

B B

R E

V

IA

T

IO

N S

AJS

12829418

KMK KPZ

1614696

ANDREW P. LEAHY

M C O M O N

W

EA

LTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No.058278P R

FRESH WATER

PUMP ROOM

USB2

PURE WATER

ROOM

USB3

MEDIUM

PRESSURE AIR

ROOM

USB4

HIGH PRESSURE

AIR ROOM

USB5

TELECOM ROOM

USB8

MAIN ELECTRICAL

ROOM

USB6

GENERATOR

ROOM

USB7

EQUIPMENT YARD

USB0

FIRE PUMP

USB1

1 2 3 4 5 6 7

A

B

C

D

8 INCH MAIN TO PIER

FPC-1

JPC-1

FPC-2

JPC-2

PIER DECK

SEE SHEET FX104 FOR CONTINUATION SEE SHEET FX104 FOR CONTINUATION

FIRE ALARM

CLOSET

USB9

HAZARD CLASSIFICATION

HAZARD SCHEDULE

ORDINARY HAZARD (CEILING 30 FT

OR LESS AFF)

EXTRA HAZARD (CEILING 30 FT OR

LESS AFF)

MARK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

DSN

JAMES E. DONAHUE, R.A.

/1

/2

:4 :5

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-F

-U S

B D h jc h o .r v t

AX100

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

F

IR

E S

U P

P R

E S

S

IO

N P

LA

N

AJS

12829419

KMK KPZ

1614696

GENERAL NOTES

1. REFER TO AX001 FOR GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS

AND SYMBOLS.

WORK NOTES

1. REFER TO SHEET AX601 FOR RISER DIAGRAM.

2. FIRE PROTECTION MAIN TO EXIT BUILDING INTO TRENCH AT THIS LOCATION

TO FEED PIER SYSTEM.

3. FIRE PROTECTION SERVICE ENTRANCE. REFER TO SHEET CU104 FOR

CONTINUATION.

4. PROVIDE FLEXIBLE COUPLING(S) ON PIPING 2-1/2" AND LARGER THAT ARE

HORIZONTALLY CROSSING THIS LOCATION WITHIN 24 INCHES OF BUILDING

EXPANSION JOINT.

5. DOMESTIC AND PURE WATER PIPING AND EQUIPMENT PERMITTED IN ROOM

PER NFPA 20, 4.14.1.1.6.

6. PROVIDE FPPS WITH AWWA C702 COMPLIANT WATER METER. REFER TO

SHEET AX601, DETAIL A1 FOR PIPING ARRANGEMENT.

7. SPRINKLER MAIN LAYOUT AND ROUTING IS CONCEPTUAL, FINAL MAIN

ROUTING IS THE RESPONSIBILITY OF THE SPRINKLER CONTRACTOR.

8. PROVIDE AUTOMATIC BALL DRIP DRAIN VALVE AT THE LOW POINT IN THE

HEATED SPACE. ROUTE DRAIN PIPING TO EXTERIOR.

1/16" = 1'-0" A1

USB - FIRE SUPPRESSION PLAN

PLAN

NORTH

8' 16' 32'0'

X

ANDREW P. LEAHY

M C O M O N

W

EA

LTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No.058278P R

FROM HEADER

DRAIN TO

EXTERIOR

TO WET

SYSTEM

AUTOMATIC AIR VENT

LOCATED AT HIGH POINT

IN SYSTEM.

INSPECTOR'S

TEST

MAIN DRAIN

PRESSURE

RELIEF

VALVE

(SET AT 175

PSI)

(S)

T O

U T

IL

IT

Y B

U

IL

D

IN

G W

E T

S Y

S T

E M

(S)

(S)

AUXILIARY DRAIN VALVESPLASH BLOCK FLANGED CONNECTION

MAIN DRAIN

PROVIDE GALVANIZED

PIPE FOR MAIN DRAIN

WHERE EXPOSED TO

EXTERIOR

EXTERIOR WALL

C1

AX601

F-2

F-1

A3

AX601

RESTRAIN IN ACCORDANCE

WITH NFPA 24

T O

P

IE

R F

P

O

T E

C T

IO

N

S Y

S T

E M

(S)

BASE WATER

DISTRIBUTION

SYSTEM

J-2

J-1

FPPS

F R

O M

F

P U

M P

S Y

S T

E M

FPBFP-1

ROUTE DRAIN

PIPING TO

EXTERIOR.

F-1

FPC-1

(S) (S)

TO PUMP TEST

HEADER

FROM WATER SUPPLY

TO FIRE SPRINKLER

RISERS

J-1

JPC-1

NC (S)

F-2

FPC-2

(S) (S)

NC (S)

J-2

JPC-2

W M

FPPS

(S)(S)

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

C I

C O

R E

H

A M

P T

O N

R O

A D

S N

A V

A L

S T

A T

IO

N

N O

R F

O L

K

N O

R F

O L

K V

A

EJA

N A

V A

L S

T A

T

IO

N N

O R

F O

R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

P

LO

T T

E D

F

IL

E

N A

M E

DRAWFORM REVISION: 07 AUG 2018

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

DSN

WMS/IAS

GEOFFREY R. MOSS

DIRECTOR OF WARFARE REQUIREMENTS

SUBMARINE FORCES ATLANTIC

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

03/05/2021

DSN

JAMES E. DONAHUE, R.A.

/1

/2

:4 :5

P

M C

R e v it P ro je c ts

\P

IE

R P

-1

-F

-U S

B D h jc h o .r v t

AX601

P -0

R

E P

L A

C E

S U

B M

A R

IN

E

P

IE

R

U S

B

F

IR

E S

U P

P R

E S

S

IO

N R

IS

E

R D

IA

G

R A

M

AJS

12829420

KMK KPZ

1614696

12" = 1'-0" C1

WET RISER DETAIL

NOT TO SCALE

A1

WET RISER DETAIL

NOT TO SCALE

A3

FIRE PUMP DETAIL

GENERAL NOTES

1. REFER TO AX001 FOR GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS

AND SYMBOLS.

WORK NOTES

1. PROVIDE AWWA C702 4 INCH NEPTUNE WATER METER INSTALLED PER

MANUFACTURER'S RECOMMENDATIONS. WATER METER MUST BE

INSTALLED NO GREATER THAN 3 FEET AFF. PROVIDE WITH 4 INCH BYPASS,

4 INCH NEPTUNE BRONZE STRAINER, AND REMOTE TOUCH PADS MOUNTED

ON EXTERIOR WALL. WATER METER MUST CAPTURE FLOW FROM FPPS

AND JOCKEY PUMPS.

2. PROVIDE THRUST RODS FOR ALL PIPE PENETRATIONS THROUGH THE

GRADE FLOOR SLAB UNLESS FLANGED OR WELDED JOINTS ARE USED

THROUGHOUT THE BELOW SLAB PIPING. ALL PIPE PENETRATIONS

THROUGH GRADE FLOOR SLAB MUST BE SLEEVED AND SEALED.

X

ANDREW P. LEAHY

M C O M O N

W

EA

LTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No.058278P R

FIRE PROTECTION - BUILDINGS
AF001-USB - FIRE ALARM NOTES, LEGEND AND ABBREVIATIONS
AF100-USB - FIRE ALARM PLAN
AF501-USB - FIRE ALARM DETAILS, FIRE ALARM ONE-LINE DIAGRAM, AND FIRE ALARM MATRIX
AX001-USB - FIRE SUPPRESSION NOTES, LEGEND AND ABBREVIATIONS
AX100-USB - FIRE SUPPRESSION PLAN
AX601-USB - FIRE SUPPRESSION RISER DIAGRAM

2021-03-18T19:06:09-0400

2021-03-18T19:06:30-0400

2021-03-18T19:06:35-0400

2021-03-18T19:06:39-0400

2021-03-18T19:06:42-0400

2021-03-18T19:06:47-0400

2021-03-18T19:07:26-0400

2021-03-18T19:07:45-0400

2021-03-18T19:07:50-0400

2021-03-18T19:07:55-0400

2021-03-18T19:08:00-0400

2021-03-18T19:08:03-0400

2021-04-28T08:00:09-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:00:36-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:00:37-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:00:43-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:00:46-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:00:47-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:00:59-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:01:12-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:01:13-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:01:17-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:01:17-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2021-04-28T08:01:21-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.

File details come from the government source that posted it. Updated .