This is an Addendum 4 to the 100% Complete Construction Documents for the National Park Service's Replace Wastewater Plant South Rim Village project (GRCA-257282). The addendum addresses bidder questions received on August 27, 2026, regarding the 100% Final Construction Documents dated June 2025.
The addendum documents minor revisions to two drawings resulting from bidder inquiries. Sheet 391 (Drawing 87S1030), the Compost Facility Structural Foundation Plan and Detail, was updated to add Detail 2 for drilled pier reinforcement specifications. Sheet 361 (Drawing 80D3002), the Digester Facility Mechanical Sections, was revised to correct detail numbering and valve sizing. No revisions to standard details or specifications were required. The revised documents are presented in markup format with additions shown in red, deletions in green, and notes in blue. Upon project award, these revisions will be incorporated into the conformed contract documents. The construction documents were prepared by Jacobs Government Services Company (Greenwood Village, CO) under Contract No. 140P2023D0006, Task Order No. 140P2023F0235.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
National Park Service
Replace Wastewater Plant South Rim Village
GRCA-257282
100% Complete Construction Documents Addendum 4
September 8, 2026
Prepared by:
Jacobs Government Services Company
Greenwood Village, CO
Contract No. 140P2023D0006
Task Order No. 140P2023F0235
Expires
.A.S.U ,ANOZI
RA
ON
ETACIFITRE
C dengiS et a
D
ROSINSKI
KATARZYNA
77237
)li vi
C( r e en ig nE la noisseforP d er et si g e
R
9- 8-2
Expires 12-31-2028
GRCA 257282 – 100% Complete CD: Addendum 04
Jacobs Engineering Group Inc. 2
1. Addendum Contents
This addendum addresses questions from bidders on the 100% Final Construction Documents for the
Replace Wastewater Plant South Rim Village project, dated June 2025, that were received by Jacobs on
August 27, 2026. The questions and responses are attached. The questions resulted in minor updates to drawings. Revisions are captured in markup format showing additions in red, deletions in green and notes in blue. Revised documents are listed below and attached. Revised documents will ultimately be incorporated into conformed contract documents after project award.
1.1 Revisions to Drawings
New or
Updated
Sheet No. DWG No. Sheet Name Description
Updated 391 87S1030 Compost Facility Structural
Foundation Plan and Detail
Added Detail 2 for drilled pier reinforcement
Updated 361 80D3002 Digester Facility Mechanical
Sections
Revised detail number and valve size
1.2 Revisions to Standard Details
New of
Updated
Standard
Detail No.
Name Description
None
1.3 Revisions to Specifications
New of
Updated
Specification
No.
Name Description
None
P L
O T D
A T
E
P L
O T T
IM
E
-J
U N -2
:3
OF
175376
0" 1"
BAR MEASURES 1" LONG
FULL SIZE DRAWINGS = 22"x34"
G R
C A -2
GRAND CANYON, SOUTH RIM
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH. REVIEW:
CADD:
DATE:
DRAWING NO.A/E FIRM
SHEET
S S /V i
06/2025 401
VILLAGE, CO
GREENWOOD
COMPANY
SERVICES
GOVERNMENT
JACOBS
PMIS/PKG NO.
257282
D S o u th R im \4 D e li v e ry \4
C
A D D e s ig n \G
R C
A \2
\M ic ro s ta ti o n V i
D ra w in g s \S
T R
U C \8
S
D .d g n
C
O M
P L E
T E C
O N
S T
R U
C T
IO
N D
O C
U M
E N
T S
PLAN
1/4"=1'-0"
N
A B C D E
A
87S3001
A
87S3001
10'-0" CLEAR, TYP
EL 6789.50
T.O. CONCRETE
AT WALLS
THICKENED SLAB
11'-0"11'-0"11'-0"11'-0"
44'-0"
TYP
SIM
1"=1'-0"
AT SIM CONDITION
INSIDE FACE ONLY
EMBED "ARMOR" ANGLES,
87S3001
"ARMOR" ANGLES
(4 PLCS), SEE NOTE 1
20" DIA CONC COLUMN
SIM
TYP
EL 6799.50,
T.O. WALL
WALL
CONCRETE
6"
6"
6" 6"
NOTE 3
SLAB ON GRADE,
CONCRETE
0330-003
B
85S3002
B
85S3002
NOTE 2
NOTE 2
CONCRETE WALL, TYP
SHEET NOTES
GENERAL SHEET NOTES
DRAWINGS 01S0001 AND 01S0002.
FOR GENERAL STRUCTURAL NOTES SEE A.
T&B.
REINFORCE SLAB-ON-GRADE WITH #5@12" EW, 3.
DRAWING 06C2001.
FACILITY LOCATION CONTROL POINT. SEE CIVIL 2.
COORDINATE LOCATION WITH MECHANICAL.1.
W KOHLER
A FIRTH
FOUNDATION PLAN
AND DETAIL
B CLEGG STRUCTURAL
COMPOST FACILITY
87S1030
0 4 8 12
1/4"=1'-0"
W/ 6" BAR SPACING
INTERSECTIONS
CORNERS AND
TYP @ ALL
SST L3x3x¼ w/ ½" DIA x
4" HAS @ 12" O.C.
DRILLED PIER
2' -6
M
IN
E
M B
E D
20" DIA
DRILLED PIER
FINISHED GRADE,
SEE CIVIL
COORD TOC W/
MECHANICAL
(6) #5 VERTS
SECTION
#3 TIES @ 12"
O.C. MAX
DRILLED PIER2
3/4"=1'-0"
P L
O T D
A T
E
P L
O T T
IM
E
\1
\2
:4
:2
P
M
OF
175376
0" 1"
BAR MEASURES 1" LONG
FULL SIZE DRAWINGS = 22"x34"
G R
C A -2
GRAND CANYON, SOUTH RIM
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH. REVIEW:
CADD:
DATE:
DRAWING NO.A/E FIRM
SHEET
S S /V i
06/2025 401
VILLAGE, CO
GREENWOOD
COMPANY
SERVICES
GOVERNMENT
JACOBS
PMIS/PKG NO.
257282
F
IL
E L
C
O M
P L E
T E C
O N
S T
R U
C T
IO
N D
O C
U M
E N
T S
C
SECTION
3/16"=1'-0"
80D1030
80D1040
SECTION
DECANTER
CL EL 6808.22
CL EL 6806.39
8" PA
REDUCER, TYP
CONCENTRIC
8"X6"
6" PA
BLR-8014
BLR-8013BLR-8012
BLR-8011
MXR-8211
AERATOR
MIXER
MXR-8212
AERATOR
MIXER
4442-715
80-PMP-8113
4" DEC HOSE
SAMPLE PUMP
DIGESTER 1
DIGESTER 2
4" DEC
MIXER/AERATOR
BLOWER
DIGESTER
BLOWER
DIGESTER
BLOWER
DIGESTER
BLOWER
DIGESTER
E
SECTION
3/8"=1'-0"
80D1030
F
SECTION
3/8"=1'-0"
80D1030
G
SECTION
3/8"=1'-0"
80D1030
TRANSFER PIPING
12" DS
6" DS
4" DEC
4027-181 SIM
TYP OF 2
SAMPLE PORT,
SILENCER
FILTER INLET
10" PA
CL EL 6779.00
CL EL 6780.95
CL EL 6785.38
6" DS
4" DEC
CL EL 6780.19, TYP
4" WAS
CL EL 6807.28
FV
TRANSFER PIPING
12" DS
4027-181
SAMPLE PORT
SIM,
HDPE
SST
CL EL 6807.28
4" WAS,
CL EL 6794.62
4" DEC
CL EL 6785.38
CL EL 6779.00
4027-191
4027-181
4027-181 SIM
4027-957
HDPE
SST
INJECTION
CHEMICAL
FUTURE
FV
SAMPLE PORT
CONNECTION
FLUSHING
4" WAS
TRANSFER PIPING
12" DS
6" V405
FV
4027-181
SAMPLE PORT
SIM,
HDPE
SST
CL EL 6794.62
4" DEC
CL EL 6785.38
TRANSFER PIPING
12" DS
CL EL 6779.00
6" DEC
4" DEC
H
SECTION
3/8"=1'-0"
80D1030
DIGESTER 2DIGESTER 1
4" RS
4" V4054" V405
3/16"=1'-0"
80D1030
80D1040
D
4" WAS
C LANCASTER
D BRUNKOW
SECTIONS
N HUBER MECHANICAL
DIGESTER FACILITY
80D3002
3/8"=1'-0"
0 4 6
40 8 16
3/16"=1'-0"
40 8 16
3/16"=1'-0"
CONCRETE
ENCASED IN
HDPE PIPE
CONCRETE
ENCASED IN
HDPE PIPE
TRANSFER PIPING
12" DS
CONCRETE
ENCASED IN
HDPE PIPE
CLDI
CS
CS
HDPE
3" V405 4" V405
4027-181
INSULATED FLANGE
2 TON HOIST
06-30-2027Expires
.A.S.U ,ANOZI
RA
ON
ETACIFITRE
C dengiS et a
D
LANCASTER
CORY
80742
)li vi
C( r e en ig nE la noisseforP d er et si g e
R
6-1 9-2
CL041386
Rectangle
CL041386
Text Box 2642-925
CL041386
Text Box 4"
CL041386
Rectangle
File details come from the government source that posted it. Updated .