B09_AMD_7_Attach_(1)_019-GC10_Amendment_07_0007.pdf
PDF 22 MB Posted
- Solicitation number
- 140P2024R0077
About this file
This document is Amendment 07 to Solicitation 140P2024R0077 for the Rehabilitate Ohanapecosh Campground project. The National Park Service is the procuring agency. The amendment modifies the Statement of Work and other contract requirements. It extends the proposal due date to March 15, 2024 and the estimated award date to April 30, 2024. The procurement is set aside for small businesses. The scope includes rehabilitating campsites, roads, and utilities at the Ohanapecosh Campground within Mount Rainier National Park. Pricing is to be submitted on a fixed-price basis. The project has an estimated value between $5-10 million. There is an incumbent contractor currently performing related work.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
OF
SHEET
DEPARTMENT OF THE INTERIOR
UNITED STATES
STATEREGION COUNTY
LOCATION WITHIN PARK
NAME OF PARK
TITLE OF DRAWING DRAWING NO.
PMIS/PKG NO.
QUALITY DESIGN CERTIFICATION
Prepared in Accordance with design
Development (Title I) Drawing No.
Variance from Design Development (Title I)
Approved by Superintendent on
Date
OR
Construction Drawing Not Preceded by
Design Development (Title I)
OR
Project Manager Date
InitialDateREVISIONSheetMark
OHANAPECOSH CAMPGROUND
MOUNT RAINIER NATIONAL PARK
WASHINGTONPACIFIC WEST LEWIS
192077
313019, 331809, &
312439
FINAL CD
WASHINGTON - N.T.S.
ANDERSON HALLAS ARCHITECTS, PC
STRUCTURAL:
JVA, INC.
BOULDER, CO
80302
CIVIL:
OTAK
REDMOND, WA
98052
MECHANICAL / PLUMBING:
360 ENGINEERING
GOLDEN, CO
80403
ELECTRICAL:
AE DESIGN
DENVER, CO
80202
PRIME / ARCH:
ANDERSON
HALLAS, PC
GOLDEN, CO
80401
140P8519D0009
PMIS
LANDSCAPE:
MUNDUS BISHOP
DENVER, CO
80204
1051 00-G002
00-G003
ADDENDUM 2 BIDDER
QUESTIONS
07/30/2024 ACN MOUNT RAINIER NATIONAL PARK
1 562
313019, 331809, & 312439
PROJECT LOCATION
MOUNT RAINIER NATIONAL PARK
REHABILITATE OHANAPECOSH CAMPGROUND
PROJECT LOCATION
MOUNT RAINIER NATIONAL PARK -
OHANAPECOSH CAMPGROUND
LOOP DIAGRAM
AMPHITHEATER; SOURCE: NPS, MORA PARK ARCHIVES, 1962
CAMPGROUND ENTRY ROAD; SOURCE: NPS, MORA PARK ARCHIVES, 1960
PACKWOOD 11.4 MILES
FROM OHANAPECOSH
CAMPGROUND VIA HWY 12
2 19-GC10 ADDENDUM 7 BIDDER
QUESTIONS
08/14/2024 ACN
" M
IN
" M
AX
SECTION
PLAN
6'- 0"
11" MIN
12" MAX
3'- 0"
3'- 0"
"-4
6"OPEN HANDLE
6"x6"
CONCRETE
COLLAR
3/4" WATER
LINE
24" ADS PIPE
3/4" ANGULAR
DRAINAGE GRAVEL
6"x6" CONCRETE
COLLAR
ABA COMPLIANT
WATER HYDRANT
24" ADS PIPE
3/4" ANGULAR
DRAINAGE GRAVEL
ATTACH YARD
HYDRANT TO ADS
PIPE PER DETAIL 3,
THIS SHEET
FROST LINE
19-
REHABILITATE OHANAPECOSH CAMPGROUND
MOUNT RAINIER NATIONAL PARK
312439
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
EM, CS
EM, AK, CS
KK
55306/21/2024
192077
GC10
DETAILS I
6 WATER SPIGOT
" M
IN
SE
P
" M
IN
SE
P
10'-0"
MIN SEPARATION
NO
N-
PO
TA
BL
E
LIN
E
W
AT
ER
LI
NE
VERTICAL SEPARATION REQUIREMENTS
HORIZONTAL SEPARATION REQUIREMENTS
ZONE 1: A) WATER AND NPWL MUST BE SEPARATED BY AT LEAST 18 INCHES AND ONE FULL,
UNCUT LENGTH OF NPWL PIPE MUST BE CENTERED ON THE CROSSING SO THAT THE
JOINTS ARE AS FAR AS POSSIBLE FROM THE CROSSING.
ZONE 2: A) ONE FULL, UNCUT LENGTH OF NPWL PIPE MUST BE CENTERED ON THE
CROSSING SO THAT THE JOINTS ARE AS FAR AS POSSIBLE FROM THE CROSSING.
AND EITHER B) NPWL MUST BE CONSTRUCTED OF WATER CLASS PIPE FOR A
DISTANCE OF 10 FEET ON BOTH SIDES OF CROSSING.
OR C) EITHER THE NPWL OR WATER LINE OR BOTH MUST BE
ENCASED WITH WATER CLASS PIPE FOR A HORIZONTAL
DISTANCE OF 10 FEET ON BOTH SIDES OF THE CROSSING.
ZONE 3: SAME REQUIREMENTS AS ZONE 2 EXCEPT THE NPWL MUST ALSO BE SUPPORTED
ABOVE THE CROSSING TO PREVENT SETTLING.
ZONE 4: SAME REQUIREMENTS AS ZONE 1 EXCEPT THE NPWL MUST ALSO BE SUPPORTED
ABOVE THE CROSSING TO PREVENT SETTLING.
NON-POTABLE LINE AND WATER LINE MUST HAVE A MIN 10' HORIZONTAL SEPARATION AND 18"
VERTICAL SEPARATION.
ZO
NE
ZO
NE
ZO
NE
ZO
NE
NOTE:
NON-POTABLE LINES INCLUDE, BUT ARE NOT LIMITED TO,
SANITARY SEWER LINES, STORM DRAIN LINES, CULVERTS, ETC.
30" SQ
PIPE, SIZE PER
PLAN
45° BEND
PVC PIPE
GASKETED SPIGOT CAP
OR MECHANICAL PLUG12" PVC
SLEEVE
FIBER JOINT
PACKING
END PLUG
CLASS 4000
CEMENT CONC.
RING AND COVER
LANDSCAPE
SECTION
PI
PE
Z
ON
E
6" MI
N.
PI
PE O.
D.
" M
IN
6"
SUITABLE, UNDISTURBED NATIVE
MATERIAL
PIPE TYPE AND SIZE
PER PLAN
SELECT BACKFILL MATERIAL COMPACTED TO
AT LEAST 95% MAXIMUM DENSITY AS PER ASTM
D1557 (MODIFIED PROCTOR)
TYPICAL CONCRETE, GRAVEL, ROADWAY OR
LANDSCAPE SECTION
NOTE:
SEE 19-C3XX SHEETS FOR
PIPE MATERIAL AND
DIAMETERS
UTILITY MARKING AND TRACING
TAPE
GRAVEL BACKFILL FOR PIPE ZONE
BEDDING
8" T
O
45° WYE
WATER LINE
NON-PORTABLE WATER
LINE (NPWL)
WATER LINE
1 UTILITY SEPARATION REQUIREMENTS
19-GC10 NTS
2 SANITARY SEWER CLEANOUT
19-GC10 NTS
3 TYPICAL SANITARY MANHOLE
19-GC10 NTS
5 SEWER UTILITY TRENCH
19-GC10 NTS
CRUSHED SURFACING TOP COURSE
6"
3"*
* INSTALL IN TWO LIFTS
HOT MIX ASPHALT
FINISHED GRADE
4 HOT MIX ASPHALT PAVEMENT RESTORATION
21-GC10 NTS
6 WATER SPIGOT (ACCESSIBLE)
19-GC10 NTS
7 WATER SPIGOT CONNECTION
19-GC10 NTS
PIPE SHALL BE CUT OUT 2" FROM
INSIDE FACE OF WALL
MINIMUM THICKNESS OF PRECAST BASE IS 6" FOR 14' DEEP OR LESS, AND
INCREASES 1" IN THICKNESS FOR EVERY 4' OF DEPTH GREATER THAN 14'
ALL JOINTS IN MANHOLE TO HAVE "O"
RING RUBBER GASKETS AND RAMNECK.
MANHOLE STEPS, COPOLYMER POLYPROPYLENE PLASTIC,
WITH 1/2" GRADE 60 STEEL REINFORCEMENT OR EQUAL, 16"
ON CENTER. (NO STEPS ALLOWED IN TOP SLAB.)
MINIMUM OF 2 MAXIMUM OF 4 ADJUSTMENT
RINGS. FINAL RING MATERIAL AND ADHESIVE TO
BE SPECIFIED BY OWNER ON A PROJECT BASIS.
NEENAH COVER, LETTERED "SANITARY SEWER", WITH 2 CONCEALED
PICK HOLES AND SELF SEALING LID. SEE SPECIFICATION FOR
CASTING NUMBER.
2 BEADS OF
RAMNEK OR
EQUAL
MANHOLE STEPS SHALL BE PLACED SO THAT OFFSET
VERTICAL PORTION OF CONE IS FACING DOWNSTREAM
NOTE: "KOR-N-SEAL" OR "A-LOCK"
FLEXIBLE CONNECTION
NOTE: ALL INFILTRATION AREAS SHALL BE
REPAIRED UNTIL MANHOLE IS WATER TIGHT.
MAXIMUM 20" ADJUSTMENT ALLOWED
INCLUDING RINGS AND CASTING.
SECTION
PLAN
PRECAST INVERT WITH A MINIMUM 1% THROUGH
SLOPE REQUIRED.
PRECAST INVERT MUST BE 1/2 DIAMETER OF THE PIPE
AND BENCHES SLOPED 2" TOWARD THE INVERT.
CASTING FRAME A B
R1642 27" 7" R1755G 28" 7"
1'- 4"
"B
"A"
VA
RI
ES
5"
4'-0"
2"
6" MI
N.
PI
PE O.
D.
6"4'
TRENCH PERIMETER
EXTEND 6" INTO NATIVE MATERIAL,
BOTTOM & SIDES OF TRENCH
IMPERMEABLE FINE GRAINED
SILTY SOIL OR CLAY
COMPACTED BACKFILL
TRENCH BOTTOM
NOTE:
PLACE EVERY 200' WHERE GRANULAR PIPE BEDDING IS USED,
AS DETERMINED BY THE GEOTECHNICAL ENGINEER.
8 TRENCH CUT-OFF DAM
19-GC10 NTS
6"
6"
| Sheets |
| 00- G000 - COVER SHEET |
| 00- G002 - SHEET INDEX |
| 00- G003 - SHEET INDEX |
| 00- GL2.11 - CS 308 CONCRETE STAIR DETAIL |
| Volume Cover Sheets |
| VOL. VII - VOLUME VII - LOOP F |
| VOL. VIII - VOLUME VIII - LOOP G |
| VOL. IX - VOLUME IX - LOOP H |
| VOL. X - VOLUME X - UTILITIES |
19-GC10 DETAILS I_REV
File details come from the government source that posted it. Updated .