RB_461A_RB-461A-06_Rev-_Sht001-008_ABS_MULTIBEAM FAIRING INSTALLATION INBOARD PROFILE _ TYPICAL SECTION.pdf

PDF 2 MB Posted

Attached to
NOAA Ship Ronald H. Brown: Mid-Life Refit
Solicitation number
1305M221RNMAN01155
Issued by

About this file

This document summarizes a solicitation for a firm fixed price contract to complete a mid-life refit of the NOAA Ship Ronald H. Brown. Key systems to be upgraded or overhauled include repowering, bow thrusters, Z-drives, potable water, chilled water, sewage, science refrigeration, uncontaminated seawater, air handling units, HVAC, tank level indicators, navigation, radar renewals, overhead lighting, security lighting, and exterior ballast and fuel tank vent renewals. Much of the ship's piping and identified steel will also be replaced. Inquiries regarding the solicitation are due by June 28, 2021 and proposals must be submitted by August 6, 2021 to the National Oceanic and Atmospheric Administration Contracting and Contract Specialist. The refit modification is intended to upgrade many of the ship's systems and components.

View the file

Other files

File Type Posted
SF30_Amendment_0008_RBML_Complete.pdf PDF
SF30_Amendment_0007_RBML_Complete.pdf PDF
SF30_Amendment_0006_RBML_Complete.pdf PDF
20065.01-02-501-01_Bow Thruster Equipment Removal and Installation Plan_Rev(-) signed.pdf PDF
WP-07G AHU-9 Addition V1.pdf PDF
SF30_Amendment_0005_Complete.pdf PDF
6932959_Rev_D_HVAC_Arrangement _Details.pdf PDF
429347_HAT PROCEDURE SBP 27 and SBP 29.pdf PDF
429348_SAT PROCEDURE SBP 27 and SBP 29.pdf PDF
18038.02-10A-514-01 AC Spaces General Electrical Modifications_Rev-_20201023.pdf PDF
WP-27 Transducer Modifications V1.pdf PDF
SF30_Amendment_0004_RBML_Complete.pdf PDF
428709_em124_hat_procedure.pdf PDF
428711_EM 124 - SAT procedure.pdf PDF
458499_em124_maintenance_manual.pdf PDF
WP 07B - AC Controls Upgrades V1.pdf PDF
RB-528- 6932929.pdf PDF
WP-11 Ships Stores Refrigeration Equipment Replacement V1.pdf PDF
20065.01-01-320-02_Ship Service Switchboard Layout_Rev(P1).pdf PDF
20065.01-01-201-01 Machinery Arrangements_Rev(P1).pdf PDF
20065.01-01-536-01 FW Cooling Diagram_Rev(P1).pdf PDF
Consolidated References_07142021.pdf PDF
20065.01-01-300-01_Electrical One-Line Diagram_Rev(P1).pdf PDF
20065.01-01-517-01 Waste Heat Diagram Rev (P1).pdf PDF
WP-00 General V2.pdf PDF
20065.01-01-211-01 Major Equipment Removal and Installation Plan_Rev(P1).pdf PDF
Keen-K4RHX100M2-43-4.625-Inch-Implr-Pump-Data.pdf PDF
20065.01-01-513-01_Generator Room Ventilation Upgrades_Rev(P1).pdf PDF
18038.02-10C-512-02_AHU5 Zone Redesign - AC System Modifications_Rev- signed.pdf PDF
RB_461A_RB-461A-07_RevA_Sht001-024_ABS_MULTIBEAM FAIRING CONSTRUCTION.pdf PDF
20065.01-01-320-01_Propulsion Switchboard Layout_Rev(P1).pdf PDF
20065.01-01-262-01 Lube Oil System Diagram_Rev(P1).pdf PDF
WP-30 Tank Level Indication Modifications V1.pdf PDF
RFP_1305M221RNMAN01155_RHB Mid-Life_REV2_071421.pdf PDF
SF30_Amendment_0003_RBML_Complete.pdf PDF
Tech Man RB-437-00.pdf PDF
6932929.pdf PDF
18038.02-12-514-01 Chilled Water Diagram_Rev- signed.pdf PDF
18038.02-10C-512-01_AHU5 Zone Redesign - Arrangements_Rev- signed.pdf PDF
18038.02-01-440-02_Machinery Control System Points List_Rev A_signed.pdf PDF
18038.02-11A-512-01 HVAC Makeup Air Upgrades_Rev- signed.pdf PDF
20065.01-01-551-01 Compressed Air Diagram_Rev(P1).pdf PDF
20065.01-01-543-01 Waste Oil Diagram_ Rev(P1).pdf PDF
20065.01-01-513-02_Natural Ventilation Trunk Modifications_Rev(P1).pdf PDF
18038.02-10B-514-01_AC Control System Mods Diagram_Rev- signed.pdf PDF
20065.01-01-300-06_Electrical One-Line Removals Diagram_Rev(P1).pdf PDF
20065.01-01-260-01 Fuel Oil System Diagrams_ Rev(P1).pdf PDF
RB_101-6932803_RevE_SHT001-0013.pdf PDF
Amendment_0002_Complete.pdf PDF
05-521-01_Rev 0.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOT REVIEWED

Acknowledged for Record

Only

1-3A (PORT) 1-3A (STBD)

ABS Letter date:

14 April 2010 Hull No: NOAASHIP

RONALD H. BROWN

VID No : YY9727531

OPN:2322142

TN:572831

NEW TRANSDUCER

FAIRING ic WING (REF 7)

1-3A (STBD)

NEW TRANSDUCER

FAIRING tc WING (REF 7)

FRAME 53 CL FRAME 43

ELEVATION 1-6A

INBOARD PRORLE

1/8"=1'-0"

COMPOSITE SECTION 1-5A

(LOOKING FORWARD)

1/8" -1 ' -0"

02 LEVEL

GENERAL NOTES

1. THIS DRAWING PRESENTS INSTALLATION REQUIREMENTS FOR THE

KONGSBERG EMI 22 1* x 1' MULT1BEAM SONAR IN A NEW FAIRING.

ITS PURPOSE IS TO SUPPORT COST & SCHEDULE ESTIMATION.

2. ALL WELDING, MATERIALS, PROCEDURES & SCANTLINGS SHALL

COMPLY WITH ABS RULES FOR STEEL VESSELS.

REFERENCES

1. GLOSTEN SPECIFICATION 05056.31

2. DWG. NO. 085-6932712 AGOR (NOAA) GENERAL ARRANGEMENT

3. DWG. NO. 801-6932861 AGOR 24 DOCKING PLAN

4. DWG. NO. 101-6932824 AGOR 24 STRUCTURAL MODULE 24

5. KONGSBERG EMI 22 INSTALLATION MANUAL

6. KONGSBERG SBP120 INSTALLATION MANUAL

7. GLOSTEN DWG NO; RB-461A-07 MULTIBEAM FAIRING CONSTRUCTION

REVISIONS

ZONE

1. TAKEN FRON GLOSTEN DRAWING

05056.31-100-03 REV -

02/18/10

NOAA

SEATTLE. WASHINGTON

NOAAS RONALD A. BRO\MN

MULTIBEAM FAIRING INSTALLATION

INBOARD PROFILE & TYPICAL SECTION

THE GLOSTEN ASSOCIATES

Consulting Etiginem Sening the Marine Community

12C1 W m m Amiu«. Suta TOO SM<4>. Wn>*tg«m 98101.2921

ra. 12oe.s24.7no

S c S i

AS NOTED

I Approved

JLRE

RB-461A-06

Sou 2-18-10

PLAN 2 - 4 A

INNERBOTTOM

1/2"-1'-0"

NOAA

SEATTLE. WASHINGTON

NOAAS RONALD A. BROWN

MULTIBEAM FAIRING INSTALLATION

INNERBOTTOM PLAN

THE GLOSTEN ASSOCIATES

Consulting Engineers Serving the Marine Community

CWK

Scai

AS NOTED

Chwk td

GW JLRE

1201 WMam Avw«M, Si*> 200 O i r t l , WnMnglon 96101.2921 TEL 12oe.e24.rsw

RB-461A-06

2-1B-10

-SKKT T

2 8

ABS Letter date:

14 April 2010 Hull No: NOAA SHIP

RONALD H. BROWN

VID No : YY9727531

OPN:2322142

TN:572831

PLAN 3-4A

TANK TOP

1/2"=1'-0"

NOT REVIEWED

Acknowledged for Record

Only

NOAA

SEATTLE. WASHINGTON

NOAAS RONALD A. BRO^

MULTIBEAM FAIRING INSTALLATION

TANK TOP PLAN

THE GLOSTEN ASSOCIATES

Consulting Engineers Serving the Marine Community

CWK

1201 WMMni Annua. S d i 200 S M « > . Wiinlngton 98101.2921 TB. I 20e.S24.7BSO

AS NOTED

Ch«ck«d lApprovvd

GW I JÛ E

RB-461A-06

Cote

2-18-10

3 8 -

PLAN 4-4A

1ST PLATFORM

1/2"-1'-0"

ABS Letter date:

14 April 2010 Hull No: NOAA SHIP

RONALD H. BROWN

VID No: YY9727531

OPN:2322142

TN:572831

NOT REVIEWED

Acknowledged for Record

Only

T

NOAA

SEATTLE. WASHINGTON

NOAAS RONALD A. BROWN

MULTIBEAM FAIRING INSTALLATION

1ST PLATFORM PLAN

THE GLOSTEN ASSOCIATES

CcnsuJtmg Bnginerrs Serxitig the Marine Coimuanty

Ch«ck«d Approved Dot*

GW JLRE 2-18-10 "cWK s?a; I Drawing Number

AS NOTED RB-461A-06

1201 WMvn AvKW Sdte 200 SoMk. Wunlngton 96101.2921 m I 20S.S24.78S0

A 8

PLAN 5-4A

MAIN DECK

1/2"=1'-0"

ABS Letter date:

14 April 2010 Hull No: NOAA SHIP

RONALD H. BROWN

VID No : YY9727531

OPN:2322142

TN:572831

NOT REVIEWED

Acknowledged for Record

Only

T

NOAA

SEATTLE. WASHINGTON

NOAAS RONALD A. BRO^

MULTIBEAM FAIRING INSTALLATION

MAIN DECK PLAN

G THE GLOSTEN ASSOCIATES

Coitsulting Engirterrs Senitrg the Marine Community

CWK

AS NOTED

1201 Wenom Avmnje. Sut» 200 Sraoh. Wishkigton 9S101.2921

ra. I 206.624.7BSO

Checked

GW

Approved

JLRE

Rot*

2-18-10 Drowing Number Sh««t of

RB-461A-06 5 8

Revision

NEW VENT PIPE

EXISTING BHD UNING

SECTION 6-7B

ELECTRONICS/COMPUTER LAB AT FRA

(LOOKING FORWARD)

1/2"=1--0-

ELEVATION 6-5B

ELECTRONICS/COMPUTER LAB BHD 3 - 6 " OFF CL (PORT)

(LOOKING TO STARBOARD)

1/2"=r-0"

ABS Letter date:

14 April 2010 Hull No: NOAA SHIP

RONALD H. BROWN

VID No : YY9727531

OPN:2322142

TN:572831

NOT REVIEWED

Acknowledged for Record

Only

NOAA

SEATTLE. WASHINGTON

NOAAS RONALD A. BRO^

MULTIBEAM FAIRING INSTALLATION

COMPUTER LAB ARRANGEMENT DETAILS

THE GLOSTEN ASSOCIATES

^^^^ Consulting Engineers Servittg the Marine Community

1201 WiiHii i A i ima. S>«a 200 Sawk. MMI«igton 98101.2921

TO. 1206^4.7090

WEB 1 www.gloston.com

D r a w n

CWK

Chackod

GW

Approved

JLRE

Oat*

2-18-10 Seal.

AS NOTED

Dronring Numb«r Sh««t of

RB-461A-06 6 8

7 - 2 0

FR 56 FR 55

zz

NEW STAINLESS STEEL 1 1/2" ROUND BAR (TYP)

NEW STAINLESS STEEL 1/2" CAP SCREW (TYP)

EXISTING BHD STIFFENER (TYP)

EXISTING BHD

FR 54

7 - 2 0

Z2 z ' / ' / / ' ' ^ / / / / ' / ^ / / / / ' / ' ^ / / / / / / ' / / / / / ' / / ^ / a

FR 52

EXISTING BHD UNING

HZ ' ' — - ~

y y / y ^ y y y / / / / y / / y / y y / y

NEW 1/2"

ALUMINUM PL

JUNCTION BOX (TYP)

A/ V A T

SPACER AS REQUIRED TO

CLEAR CAP SCREWS (TYP)

A T A V a

V

PLAN 7-50

TYPICAL EMI 22 JUNCTION BOX FOUNDATION

1 1/2"=«1'-0"

7 -2A EXISTING BHD STIFFENER (TYP)

EXISTING BHD

' y / -7-7 ~

NEW STAINLESS STEEL 1 1/2* RB (TYP)

NEW STAINLESS STEEL 1/2" CAP SCREW (TYP)

,7/ ' / / / / / / / .'• - / / / / / / / / / / ^ / / / ^ / / ZZ - ' • / <W / / / r / /, ^ ^ ^ ^ ^ ^ ^ a ^ EXIslw^^piO UNING y y / T T

7-2A

NEW ALUMINUM

10"x 1/4" CHANNEL

PREAMP/TRANSCEIVER

A T

• ' / '— SPACER AS REQUIRED TO

CLEAR CAP SCREWS (TYP)

PLAN 7-6A

TYPICAL EM122 PREAMP FOUNDATION

(EMI 22 & SBP120 TRANSCEIVER FOUNDATIONS SIMILAR)

1 1 / 2 ' = 1 - 0 " ABS Letter date:

14 April 2010 Hull No: NOAASHIP

RONALD H. BROWN

VID No : YY9727531

OPN:2322142

TN:572831

EXISTING BHD UNING

EXISTING BHD STFFENER

BOLT EQUIPMENT TO

PLATE (PROVIDE

SPACERS AS REQ'D

TO CLEAR CAP SCREWS)

NEW STAINLESS STEEL 1 1/2"

ROUI^ \ A | \ TAPPED FOR

'SCREW (TYP) /

NEW 1/2"x 2" LG

STAINLESS STEEL

CAP SCREW (TYP)

NEW 1/2" ALUMINUM PL

DETAIL 7 -20

TYPICAL EMI 22 JUNCTION BOX FOUNDATION

3 - -1 ' - 0 "

EXISTING BHD UNING

NEW ALUMINUM ^ ^'^'SJINGBHD —

10"x 1/4" CHANNEL \

STIFFENER

NEW 1/2"x 2'

STAINLESS STEEL

CAP SCREW (TYP)

BaT EQUIPMENT TO CHANNEL — .

(PROVIDE SPACERS AS REQ'D \

TO CLEAR CAP SCREWS) -

V

Z : : i>

A T

EXISTING BHD

NEW STAINLESS STEEL

1 1/2" ROUND BAR TAPPED

FOR 1/2" CAP SCREW (TYP)

NOT REVIEWED

Acknowledged for Record

Only

DETAIL 7-2A

TYPICAL EMI 22 PREAMP FOUNDATION DETAIL

(EMI 22 & SBP120 TRANSCEIVER FOUNDATIONS SIMILAR)

3 " = 1 - 0 "

NOAA

SEArr iE , WASHINGTON

NOAAS RONALD A BROWN

MULTIBEAM FAIRING INSTALLATION

EQUIPMENT FOUNDATION DETAILS

THE GLOSTEN ASSOCIATES

Consulting Engineers Sening the Marine Community

1201 Wimi i i A»«nu». Sijta 200 SMttt. WaaNngton 90101-2921

IB. I 206.624.7850

Orai«n Ch«ck»d

CWK I GW

Seal*

AS NOTED

JLRE

RB-461A-06

I 2 - 1 8 - 1 0 Sknl of IRr

7 8

NEW 1 1/2' SCH 80

LR RETURN BEND

NEW VENT SCREEN

NEW 1 1/2" SCH 80 VENT PIPE

01 DECK

ELEVATION 8-5D

^ VENT DETAIL

^ 1/2"-1'-0"

ABS Letter date:

14 April 2010 Hull No: NOAA SHIP

RONALD H. BROWN

VID No : YY9727531

OPN:2322142

TN:572831

PLAN 8-6A

01 LEVEL

1 /2" - r -0"

NOT REVIEWED

Acknowledged for Record

Only

NOAA

SEATTLE. WASHINGTON

NOAAS RONALD A. BROVM

MULTIBEAM FAIRING INSTALLATION

01 LEVEL PLAN

THE GLOSFEN ASSOCIATES

Consulting Engineers Serving the Marine Community

CWK

J j J , AS NOTED

1201 WMMITI Annua, SiiM 200 SMtta. WisMngton 9S10I-2921 TO. I 20e.624.n9O

Shacked

GW

Appro v M

JLRE

ba{* 2-18-10

Drawing Numbar Shaat of

RB-461A-06 8 8

File details come from the government source that posted it. Updated .