This solicitation is for a firm fixed price contract to complete a mid-life refit of the NOAA Ship RONALD H. BROWN. The refit includes upgrades to major ship systems such as repowering, bow thrusters, sewage pumps, science refrigeration, HVAC, piping and steel replacement. Proposals are due by August 6, 2021 and shall be submitted to the Contracting Officer and Contract Specialist at NOAA. Inquiries are due by June 28, 2021 and shall be sent to the points of contact listed. The purpose is to establish a contract for all labor, materials and equipment to deliver the complete refit in accordance with the previously completed ABS report.
View the file
Other files for this federal contract opportunity
Show all 50
NOAA Ship Ronald H. Brown: Mid-Life Refit has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECESSED IMPELLER
• Handles Stringy and Fibrous Materials
• Passes Large Solids
• Pumps Heavier Solids Concentrations
• Ideal for Grit and Abrasive Solids
• Pumping via Vortex Action
• Solids Do Not Pass through Impeller
• Virtually Impossible to Clog
STRONG PERFORMANCE
• Ideal for Higher heads, Lower flows
• Operate to Shut-off Head without Damage
• Non-overloading Performance Curve
LONG SERVICE LIFE
• Dual Silicon Carbide Shaft Seals
• Low Motor Operation Temperatures
• Continuously Lubricated Bearings
• Premium 3-Bearing Construction
• Epoxy Potted Cord Entry
LOW MAINTENANCE
• No Wear Components
• Recessed Impeller out of Passageway
• Grit-Resistant Silicon Carbide Shaft Seals
CAPABILITIES:
• Flows-------------------------------------- to 540 GPM
• Heads------------------------------------- to 94 Feet
• HP Range-------------------------------- 7.5 - 15 HP
• Voltage / Phase Options------------- 208/230 V, 1 Phase - 208/230/460 V, 3 Phase
• Discharge Connections-------------- 4” ANSI Class 125 Horizontal Flange
• Motor Speeds--------------------------- 3450 RPM
• Solids-Handling------------------------ 3”
• Impeller---------------------------------- Recessed, Vortex
• Motor Service Factor----------------- 1.20
Solids-Handling Pumps
K4RH(X)
4” Submersible, Recessed Impeller
(Class 1, Div. 1, Groups C & D Hazardous Location)
Rev. 03/2018 rpruit Line
471 US HWY 250 East . Ashland, Ohio 44805
419.207.9400 fax 419.207.8031 www.keenpump.com
Features and Bene�ts
1. Watertight Cable Entrance Heavy-duty molded compression grommet protects outer cord jacket. *Explosion-proof cable entrance option provides agency-approved, watertight strain relief cord grips with compression grommets to protect outer cord jacket. Epoxy-filled inner cord cap provides anti-wicking moisture protection to the motor even if power cable is cut or damaged. 40’ UL power & control cords.
2. Modular Pump Design Commonality of parts across the Keen product line minimizes the amount of parts required for servicing. Heavy-duty ASTM A48, Class 35 cast iron components.
3. Strong Motor Powerful high-torque motor for reliable pump operation. Pressed stator securely holds motor and efficiently transfers heat to cast housing. Class F insulation with overload protection in oil-filled chamber for cool operation and long motor life.
3a. Oil Proprietary Keen oil ensures industry-low operating temperatures.
4. 3-Bearing Support Motor / Pump shaft securely held with upper and lower ball bearing plus additional sleeve bearing in lower seal chamber.
Long 50,000 hour B-10 bearing life.
5. Severe Duty Dual Mechanical Seals Dual silicon carbide mechanical shaft seals provide twice the moisture and grit protection for the motor. Dual seals are housed in a secondary oil-filled seal chamber. Tougher silicon carbide seals better handle sand, grit and abrasive materials.
6. Moisture Detection Seal leak probe signals alarm in control panel for scheduled maintenance.
7. Non-Overloading Hydraulic Design Recessed centrifugal impeller allows 100% performance curve operation from shut-off to maximum flow without damage to the pump or system. The recessed, vortex impeller is out of the passageway of fluid flow, eliminating concerns of blockage or wear.
8. 3” Solids-Handling Clear, unobstructed passageway provides reliable movement of solids.
9. Standard Flange Connection 4“ Horizontal, Class 125 ANSI discharge flange. Industry standard, 8-bolt pattern.
7 8
K4RH(X)
Rev. 03/2018
Pump Data Sheet - Keen Pump Inc.
Company: Carolina Pumpworks, LLC Name: Robert Pruit Date: 08/12/2020
NOAA Ship Ronald H. Brown
Pump:
Size:
Type:
K4RHX
Submersible Sewage
Synch Speed: 3600 rpm
Curve: ---
Dia: 4.625 in
Pump Limits:
Temperature: --- Wkg Pressure: ---
Sphere Size: 3 in
Search Criteria:
Flow:
40 ft
Fluid:
Water
SG: 1
Density: 62.4 lb/ft³ Viscosity: 1.1 cP
Temperature: 60 °F
Vapor Pressure: 0.256 psi a Atm Pressure: 14.7 psi a
Motor:
Standard: NEMA Enclosure: TEFC
Sizing Criteria: Max Power on Design Curve
Size: 10 hp Speed: 3600 rpm
Frame: 215T
Near Miss:
0 ft
276 US gpm Head:
Static Head:
Dimensions: Suction:
4 inDischarge:
--- Name:
Pump Selection Warnings:
None
--- Duty Point ---
Flow: 276 US gpm Head: 40 ft Eff: 33.5% Power: 8.08 hp NPSHr: ---
--- Design Curve --- Shutoff Head: 68.8 ft Shutoff dP: 29.8 psi Min Flow: --- US gpm
BEP: 34.5% @ 232 US gpm NOL Power:
8.8 hp @ 390 US gpm
--- Max Curve --- Max Power:
13.3 hp @ 474 US gpm
Speed: 3450 rpm
Performance Evaluation:
Flow Speed Head Efficiency Power NPSHr US gpm rpm ft % hp 331 3450 33.8 32.3 8.63 --- 276 3450 40 33.5 8.08 --- 221 3450 46.6 34.3 7.43 --- 166 3450 54.3 33.2 6.35 --- 110 3450 62.2 32.2 5.26 ---
Selected from catalog: Keen.60, Vers 1.3.0
Name: Robert Pruit Date: 08/12/2020
Keen Pump Inc.
Catalog: Keen.60, Vers 1.3.0 Submersible Sewage - 3600 rpm Design Point: 276 US gpm, 40 ft Static Head: 0 ft
Size: K4RHX Speed: 3450 rpm Dia: 4.625 in Curve: ---
Name: Robert Pruit Date: 08/12/2020
Keen Pump Inc.
Catalog: Keen.60, Vers 1.3.0 Submersible Sewage - 3600 rpm Design Point: 276 US gpm, 40 ft Static Head: 0 ft
Size: K4RHX Speed: 3450 rpm Dia: 4.625 in Curve: ---
�TKEEN PUMP" Section VORTEX
Dated July 2017
Pump Model: K4RHX
Physical Data:
Discharge Size ANSI 4" Horizontal
Solids Size 3"
Impeller Type Balanced, Vortex, 10-Vane
Power/Control Cable Length 40' Standard
Paint Blue, Water Reducible Enamel, One Coat, Air Dried - Standard
Motor Construction:
Motor Type Enclosed Submersible Oil Filled
NEMA Insulation Code Class F
Service Factor 1.2
NEMA Design Type B (30) L (10)
Single Phase Configuration External Start and Run Components
Motor Protection Thermal Sensors Embedded in the Windings
Maximum Stator 311 °F (155°C) Temperature
Power Cord Type SOOW - 600V, 90° C; Type W - 2000V, 90° C
Control Cord Type 16-4 or 18-5 - SOOW - 600V, 90° C
Materials of Construction:
Cord Entry Cast Iron, ASTM A48, Class 35
Motor Housing Cast Iron, ASTM A48, Class 35
Bearing Housing Cast Iron, ASTM A48, Class 35
Volute Cast Iron, ASTM A48, Class 35
Impeller Ductile Iron, ASTMA536, 60-40-18
Shaft ANSI 400 Stainless Steel
Inboard Mechanical Seal Silicone Carbide / Silicone Carbide
Outboard Mechanical Seal Silicone Carbide / Silicone Carbide
Fasteners ANSI 18-8 Stainless Steel
0-Rings Nitrile Rubber
Upper Bearing Conrad Style Single Row Deep Groove Ball Bearing
Lower Bearing Conrad Style Single Row Deep Groove Ball Bearing
Line Bearing Bronze, CDA 836
K4RHX M2 PGl
Two cables: Power 4 gage(.58" OD) Sensor 14gage(.59 OD)
�TKEENPUIIP Section VORTEX
Dated FEB 2016
Pump Model: K4RHX - 3450 RPM
Thermal Data:
Maximum Liquid 140° F ( 60° C) Intermittent
Maximum Stator 311° F(155° C)
Heat Sensor Open: 257° F (125° C) Max./ 239° F (115° C) Min.
Closed: 194° F (90° C) Max./ 119° F (48° C) Min.
Oil Flash Point 390° F (199° C)
Electrical Data:
RPM 3450
Electrical Ratings Heat 24VDC 115VAC 230VAC Sensor 5AMPS 5AMPS 5AMPS
Seal Fail 300V AC 5mAMPS
Voltage Tolerance ± 10%
Full Locked NEC Service Load SF Rotor Run Start Run
HP Volta�e Phase Code Factor AMPS Amos AMPS KW KVA KVA
7.5 230 1 L 1.2 32.5 39.0 113.8 7.5 26.3 9.8
208 22.1 26.5 77.4
7.5 230 3 L 1.2 19.9 23.9 69.7 6.3 27.9 9.3
460 10.0 11.9 34.8
208 29.1 34.9 101.9
10 230 3 J 1.2 26.2 31.5 91.8 8.3 36.7 7.3
460 13.1 15.7 45.9
208 45.2 54.2 158.2
15 230 3 J 1.2 44.1 48.9 142.5 12.8 56.9 7.6
460 22.1 24.4 71.3
Motor Efficiencies & Power Factor Motor Efficiency % Power Factor %
Service Service Factor 100% 75% 50% Factor 100% 75% 50%
HP Phase Load Load Load Load Load Load Load Load
7.5 1 65 65 64 59 86 83 76 62
7.5 3 78 78 75 70 79 76 71 60
10 3 75 76 75 70 79 78 71 59
15 3 74 76 74 68 78 77 72 58
K4RHX M2 PG2
rpruit Rectangle rpruit Line rpruit Line rpruit Line rpruit Line rpruit Line rpruit Rectangle
File: K4RHX Dimensions
Pump Series K4RHX 4” SUBMERSIBLE SEWAGE PUMPS
Section Date
VORTEX
MAR 2015
DIMENSIONAL DATA
Note: All dimensions in inches unless noted.
Dimensions may vary due to normal manufacturing tolerances.
36”
29-1/2”
2-5/16”
5-5/16”
5-3/16”
4-3/8”
7-1/2”4-1/4”
REWOP
ELBAC
ESAB "4
WOBLE
C
A
B
C
1 2 3
EGRAHCSID "4
PMUP VLS/1LS
EDILS GNITSIXE
PMALC
GNITNUOM GNITSIXE
SREHSAW DNA STLOB
SNOITCURTSNI
EDILS MORF PMUP L-E EGRAHCSID '4 CCY GNITSIXE ETARAPES.1
.PMALC
)4 METI( TEKSAG GNIZILITU ,PMUP OT )1 METI( ROTPADA TLOB.2
.)7,6,5 ,3 ,2 SMETI(,SREHSAW & ,STUN ,STLOB DNA
.PMALC EDILS OT YLBMESSA ETALP ROTPADA/PMUP TLOB.3
)SPMUS PMUP REDNU RO SLATSEDEP DELLATSNI( NGISED TIP :ETON
DEIFIREV PMUP WOLEB SECNARAELC DNA DEKCEHC EB TSUM
ETAIRPORPPA EHT GNITCELES OT ROIRP NOITACILPPA EHT ROF
.PMUP VLS RO 1LS EHT GNILLATSNI DNA TIK ROTPADA
METI
.ON REBMUN TRAP NOITPIRCSED .YTQ
1 736501-M IC,PY,F-F"52.5,LE"4 OT LQ"4,RTPDA 1
2 01-94-1C SS613,"4/1-3 X 11-"8/5,SCHH 8
3 11-21-21C SS613,EAS,TALF,"8/5,RHSW 8
4 53833-M KHT"8/1 ,BL 051/521 ,"4 ,TEKSAG 1
5 11-21-21C SS613,EAS,TALF,"8/5,RHSW 8
6 7-9-71C SS403,11-"8/5,TUN 8
LEDOM PMUP A B C
02.04A.03.1LS 81.52 06.13 95.3
03.04A.03.1LS 81.52 06.13 95.3
04.04A.03.1LS 30.72 53.43 53.3
55.04A.03.1LS 30.72 53.43 53.3
57.04A.03.1LS 30.72 53.43 53.3
001.04A.03.1LS 83.72 43.53 45.3
55.04A.04.1LS 80.72 77.53 74.3
57.04A.04.1LS 80.72 77.53 74.3
001.04A.04.1LS 57.62 77.53 74.3
51.04A.03.VLS 69.32 94.03 17.3
81.04A.03.VLS 69.32 94.03 17.3
02.04A.03.VLS 69.32 94.03 17.3
03.04A.03.VLS 69.32 94.03 17.3
55.04A.03.VLS 37.52 28.23 57.3
08.04A.03.VLS 37.52 28.23 57.3
001.04A.03.VLS 04.62 21.43 61.3
521.04A.03.VLS 04.62 21.43 61.3
051.04A.03.VLS 04.62 21.43 61.3
04.04A.04.VLS 83.52 64.23 27.2
55.04A.04.VLS 83.52 64.23 27.2
57.04A.04.VLS 83.52 64.23 27.2
001.04A.04.VLS 40.62 67.33 27.2
DCBA
DCBA
NOITPIRCSED / .ON NCE ENOZ ETAD VER D'KC YB
DEIFICEPS ESIWREHTO SSELNU
SECNARELOT ENIHCAM DRADNATS
SEHCNI NI SNOISNEMID LLA
01/71/9
60. ± SHTPED PAT & LLIRD LLA
LAMICED ECALP EERHT 500.±
LAMICED ECALP OWT 20.±
XAM 530. R RENROC EDISNI
530.-500. SEGDE EDISTUO KAERB
NOITAROPROC
OGACIHC SNAMOEY
911311-A
SEHCNI NI SNOISNEMID
310-72550090 NP ,L-E "4 OT VLS/LS"4,YSSA RTPDA
SEIRAV
RIT 500.
SMR 521
L-E "4 OT "4 VLS/1LS ,YSSA
RIT 500.
RIT 500.
RIT 500.
°5. ±
LJ B
FO YTREPORP EHT SI GNIWARD SIHT
NOITAROPROC OGACIHC SNAMOEY
DNA ECNEDIFNOC NI DETTIMBUS SI DNA
,DEIPOC ,DECUDORPER EB TON LLAHS
GNIWARD .SREHTO OT DESOLCSID RON
.TSEUQER NOPU DENRUTER EB OT
GNIWARD
ELACS
TON OD
GH
VLS & 1LS
STN
.VER:ETAD
EZIS
.GWD .ON .GWD
ASU ,LI ,ARORUA
NOITPIRCSED
LEDOM .ON NRETTAP:ELACS
:YB DEKCEHC
.ON REDRO
:YB DEVORPPA
:THGIEW
TOLP
NOITCEJORP ELGNA DRIHT
rpruit Line rpruit Line rpruit Text Box A Grundfos/YCC 4" SL (ANSI) to 4" EL Adaptor Flange is Required. This Adaptor Flange will enable the Keen K4RHX100M2-43, 4" ANSI flanged discharge pump to mate with the existing YCC EL Style 4" Base Elbow. The existing YCC EL Style Sealing Flange will attach to the Adaptor Flange that will then be attached to the Keen Pump discharge flange. This Adaptor Flange adds 5.25" (Flg-Flg) to the pump lay length dimension (from discharge flange face to back of pump).
rpruit Line
File: K4RHX Liftout Dimensions
Section Date
VORTEX
MAR 2015
LIFTOUT DIMENSIONAL DATA
Notes:
1. All dimensions in inches unless noted.
2. Discharge �ange ANSI Class 125 unless noted.
3. Absolute minimum and recommended minimum submergence levels noted.
4. Discharge base elbow must be placed above sump bottom as noted.
5. Dimensions may vary due to normal manufacturing tolerances.
6. If discharge pipe is larger than discharge elbow, eccentric reducer must be used limited to 2X larger maximum.
rpruit Text Box This page for reference only. This page is NOT applicable unless you replace the existing pump guide system (base elbow, sealing flange, guide rail pipes and upper guide rail bracket) with a new Keen Pump Guide System.
File: K4RHX Install Dimensions
Section Date
VORTEX
MAR 2015
SIMPLEX INSTALLATION DIMENSIONAL DATA
Notes:
1. All dimensions in inches unless noted.
2. Refer to pump dimension and liftout dimension sheets for more details.
3. Recommended minimum submergence levels noted.
4. Discharge base elbow must be placed above sump bottom as noted.
5. Dimensions may vary due to normal manufacturing tolerances.
6. If discharge pipe is larger than discharge elbow, eccentric reducer must be used limited to 2X larger maximum.
rpruit Text Box This page for reference only. This page is NOT applicable unless you replace the existing pump guide system (base elbow, sealing flange, guide rail pipes and upper guide rail bracket) with a new Keen Pump Guide System.