This document contains a federal solicitation and related project specifications for renovating a pharmacy. The solicitation is for project number 629-18-127 to remodel an existing pharmacy compounding area and build a new segregated compounding area at the Southeast Louisiana Veterans Health Care System in New Orleans to meet USP 800 standards. The project value is between $1,000,000 to $5,000,000. The NAICS code is 236220 and it is set aside 100% for service-disabled veteran-owned small businesses. The related specifications indicate the contractor must provide all labor, materials and equipment to complete the pharmacy renovation and include building out the new segregated compounding area. Key materials specified are stainless steel wall guards and fasteners.
View the file
Other files
Show 40 more
Latest 50 of 77 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Renovate Pharmacy for USP 800 VAMC New Orleans, LA 10-01-15
SECTION 10 26 00
WALL AND DOOR PROTECTION
PART 1 - GENERAL
1.1 DESCRIPTION
A. This section specifies wall guards.
1.2 RELATED WORK
A. Armor plates and kick plates not specified in this section: Section 08 71 00, DOOR HARDWARE.
1.3 QUALITY ASSURANCE
A. Manufacturer’s Qualifications: Manufacturer with a minimum of three (3) years’ experience in providing items of type specified.
1. Obtain wall and door protection from single manufacturer.
B. Installer’s Qualifications: Installers are to have a minimum of three (3) years’ experience in the installation of units required for this project.
1.4 SUBMITTALS
| A. | Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. |
| B. | Shop Drawings: Show design and installation details. |
| C. | Manufacturer's Literature and Data: |
| 1. | Wall Guards. |
D. Manufacturer’s warranty.
1.5 DELIVERY AND STORAGE
| A. | Deliver materials to the site in original sealed packages or containers marked with the name and brand, or trademark of the manufacturer. |
| B. | Protect from damage from handling and construction operations before, during and after installation. |
| C. | Store in a dry environment of approximately 21 degrees C (70 degrees F) for at least 48 hours prior to installation. |
1.6 warranty A. Construction Warranty: Comply with FAR clause 52.24621 “Warranty of Construction”.
B. Manufacturer Warranty: Manufacturer shall warranty their wall and door protection for a minimum of five (5) years from date of installation and final acceptance by the Government. Submit manufacturer warranty.
1.7 APPLICABLE PUBLICATIONS
| A. | Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only. |
| B. | ASTM International (ASTM): |
| A240/A240M-14 | Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and For General Applications |
| B221-14 | Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes |
| B221M-13 | Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric) |
| D256-10 | Impact Resistance of Plastics |
| D635-10 | Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position |
| E84-14 | Surface Burning Characteristics of Building Materials |
| C. | Aluminum Association (AA): |
| DAF 45-09 | Designation System for Aluminum Finishes |
D. American Architectural Manufacturers Association (AAMA):
| 611-14 | Anodized Architectural Aluminum |
| E. | Code of Federal Regulation (CFR): |
| 40 CFR 59 | Determination of Volatile Matter Content, Water Content, Density Volume Solids, and Weight Solids of Surface Coating |
| F. | The National Association of Architectural Metal Manufacturers (NAAMM): |
| AMP 500-06 | Metal Finishes Manual |
| G. | National Fire Protection Association (NFPA): |
| 80-13 | Standard for Fire Doors and Windows |
| H. | SAE International (SAE): |
| J 1545-05(R2014) | Instrumental Color Difference Measurement for Exterior Finishes. |
| I. | Underwriters Laboratories Inc. (UL): |
| Annual Issue | Building Materials Directory |
PART 2 - PRODUCTS
2.1 MATERIALS
A. Stainless Steel: A240/A240M, Type 304.
to produce specified color. //
2.2 WALL GUARDS
A. Stainless Steel Wall Guards: Construct wall guard, including brackets, of minimum 4.76 mm (0.1875inch) thick stainless steel.
2.3 FASTENERS AND ANCHORS
| A. | Provide fasteners and anchors as required for each specific type of installation. |
| B. | Where type, size, spacing or method of fastening is not shown or specified in construction documents, submit shop drawings showing proposed installation details. |
2.4 FINISH
A. Stainless Steel: In accordance with NAAMM AMP 500 finish Number 4.
PART 3 - INSTALLATION
3.1 STAINLESS STEEL WALL GUARDS
A. Space brackets at not more than 914 mm (3 feet) on centers and anchor to the wall in accordance with manufacturer's installation instructions.