This document contains a federal contract solicitation for remodeling pharmacy services to meet USP 800 requirements. The solicitation is for a 100% Service-Disabled Veteran-Owned Small Business set-aside to provide all labor, materials, tools, and equipment to remodel the current pharmacy compounding area and build out a new segregated compounding area at the Southeast Louisiana Veterans Health Care System facility in New Orleans. The project cost is estimated to be between $1,000,000 and $5,000,000. Offerors must be verified as a Service-Disabled Veteran-Owned Small Business in the Vendor Information Pages database. The work is to be performed in New Orleans, Louisiana under NAICS code 236220 with a small business size standard of $39.5 million. The solicitation includes requirements for registration in the System for Award Management database.
View the file
Other files
Show 40 more
Latest 50 of 77 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Renovate Pharmacy for USP 800 10-01-17 VAMC New Orleans, LA
SECTION 07 21 13
THERMAL INSULATION
GENERAL
SUMMARY
Section Includes:
Acoustical insulation.
Batt and blanket insulation at interior framed partitions and ceilings.
RELATED REQUIREMENTS
Safing Insulation: Section 07 84 00, FIRESTOPPING.
APPLICABLE PUBLICATIONS
Comply with references to extent specified in this section.
ASTM International (ASTM):
C55215 - Cellular Glass Thermal Insulation.
C55313 - Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications.
C66512 - MineralFiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing.
C95415 - Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Base to Steel Studs From 0.033 (0.84 mm) inch to 0.112 inch (2.84 mm) in thickness.
C100214 - Steel SelfPiercing Tapping Screws for Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs.
E8415a - Surface Burning Characteristics of Building Materials.
F166715 - Driven Fasteners: Nails, Spikes, and Staples.
SUBMITTALS
Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
Manufacturer's Literature and Data:
Description of each product.
Adhesive indicating manufacturer recommendation for each application.
DELIVERY
Deliver products in manufacturer's original sealed packaging.
Mark packaging, legibly. Indicate manufacturer's name or brand, type, production run number, and manufacture date.
Before installation, return or dispose of products within distorted, damaged, or opened packaging.
STORAGE AND HANDLING
Store products indoors in dry, weathertight facility.
Protect products from damage during handling and construction operations.
WARRANTY
Construction Warranty: FAR clause 52.246-21, "Warranty of Construction."
PRODUCTS
INSULATION - GENERAL
Insulation Thickness:
Provide thickness required by Rvalue shown on drawings.
Provide thickness indicated when Rvalue is not shown on drawings.
Insulation Types:
Provide one insulation type for each application.
Sustainable Construction Requirements:
Insulation Recycled Content:
Rock wool material: 75 percent recovered material.
ACOUSTICAL INSULATION
Semi Rigid, Batts and Blankets:
Widths and lengths to fit tight against framing.
Mineral Fiber boards: ASTM C553, Type II, flexible, or Type III, semi rigid unfaced.
Density: nominal 4.5 pound.
Mineral Fiber Batt or Blankets: ASTM C665 unfaced.
Maximum Surface Burning Characteristics: ASTM E84.
Flame Spread Rating: 25.
Smoke Developed Rating: 450.
ACCESSORIES
Fasteners:
Staples or Nails: ASTM F1667, zinccoated, size and type to suit application.
Screws: ASTM C954 or ASTM C1002, size and length to suit application with washer minimum 50 mm (2 inches) diameter.
Impaling Pins: Steel pins with head minimum 50 mm (2 inches) diameter.
Length: As required to extend beyond insulation and retain cap washer when washer is placed on pin.
Adhesive: Type recommended by manufacturer to suit application.
Tape:
Pressure sensitive adhesive on one face.
EXECUTION
PREPARATION
Examine and verify substrate suitability for product installation.
Protect existing construction and completed work from damage.
Clean substrates. Remove contaminants capable of affecting subsequently installed product's performance.
INSTALLATION - GENERAL
Install products according to manufacturer's instructions and approved submittal drawings.
When manufacturer's instructions deviate from specifications, submit proposed resolution for Contracting Officer's Representative consideration.
Install insulation with vapor barrier facing the heated side, unless indicated otherwise.
Install batt and blanket insulation with joints tight. Fill framing voids completely. Seal penetrations, terminations, facing joints, facing cuts, tears, and unlapped joints with tape.
Fit insulation tight against adjoining construction and penetrations, unless indicated otherwise.
ACOUSTICAL INSULATION
General:
Install insulation without voids.
Pack insulation around door frames and windows, in building expansion joints, door soffits, and other voids.
Pack behind outlets, around pipes, ducts, and services encased in walls.
Hold insulation in place with pressure sensitive tape.
Lap facer flanges together over framing for continuous surface. Seal all penetrations through the insulation and facers.
Do not compress insulation below required thickness except where embedded items prevent required thickness.
Semi Rigid, Batts and Blankets:
When insulation is not full thickness of cavity, adhere insulation to one side of cavity, maintaining continuity of insulation and covering penetrations or embedments.
Wood Framing:
Fasten blanket insulation between wood framing and joists with nails or staples through flanged edges of insulation.
Space fastenings maximum 150 mm (6 inches) on center.
Metal Framing:
Fasten insulation between metal framing with pressure sensitive tape continuous along flanged edges.
At metal framing or ceilings suspension systems, install blanket insulation above suspended ceilings or metal framing at right angles to the main runners or framing.
Tape insulation tightly together so no gaps occur and metal framing members are covered by insulation.
CLEANING
Remove excess adhesive before adhesive sets.
PROTECTION
Protect insulation from construction operations.
Repair damage.
- E N D - 07 21 13 - 1