This file contains a federal construction solicitation and related project specifications. The solicitation seeks a contractor to remodel a pharmacy compounding area and build a new segregated compounding area at a Veterans Health Care facility in New Orleans, Louisiana to meet USP 800 requirements. The procurement is set aside only for verified Service-Disabled Veteran-Owned Small Businesses. The construction project cost is estimated between $1,000,000 to $5,000,000. Offerors must be registered in the System for Award Management and eligible as an SDVOSB in the Vendor Information Pages database. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The project specifications provide requirements for glazing, glass thickness and types, installation methods, and a glass schedule.
View the file
Other files
Show 40 more
Latest 50 of 77 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Renovate Pharmacy for USP 800 VAMC New Orleans,LA 10-01-1
SECTION 08 80 00
GLAZING
PART 1 - GENERAL
1.1 DESCRIPTION:
A. This section specifies the following:
1. Glass.
2. Glazing materials and accessories for both factory and field glazed assemblies.
1.2 RELATED WORK:
A. Factory glazed by manufacturer in following units:
1. Doors: Section 08 11 13, HOLLOW METAL DOORS AND FRAMES, and Section 08 14 00, WOOD DOORS.
1.3 LABELS:
| A. | Temporary labels: |
| 1. | Provide temporary label on each light of glass identifying manufacturer or brand and glass type, quality and nominal thickness. |
| 2. | Label in accordance with NFRC label requirements. |
| 3. | Temporary labels are to remain intact until glass is approved by Contracting Officer Representative (COR). |
| B. | Permanent labels: |
| 1. | Locate in corner for each pane. |
| 2. | Label in accordance with ANSI Z97.1 and SGCC label requirements. |
| a. | Tempered glass. |
1.4 PERFORMANCE REQUIREMENTS:
| A. | General: Design glazing system consistent with guidance and practices presented in the GANA Glazing Manual, GANA Laminated Glazing Manual, and GANA Sealant Manual, as applicable to project. Installed glazing is to withstand applied loads, thermal stresses, thermal movements, building movements, permitted tolerances, and combinations of these conditions without failure, including loss or glass breakage attributable to defective manufacture, fabrication, or installation; failure of sealants or gaskets to remain watertight and airtight; deterioration of glazing materials; unsafe engagement of the framing system; deflections beyond specified limits; or other defects in construction. |
| B. | Glazing Unit Design: Design glass, including engineering analysis meeting requirements of authorities having jurisdiction. Thicknesses listed are minimum. Coordinate thicknesses with framing system manufacturers. |
| 1. | Design glass in accordance with ASTM E1300, and for conditions beyond the scope of ASTM E1300, by a properly substantiated |
2. Maximum Lateral Deflection: For glass supported on all four edges, limit center-of-glass deflection at design wind pressure to not more than the structural capacity of the glazing unit, the threshold at which frame engagement is no longer safely assured, 1/100 times the short-side length, or 19 mm (0.75 inch), whichever is less.
1.5 SUBMITTALS:
A. In accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B. Manufacturer's Certificates:
| 1. | Certificate stating that fire-protection and fire-resistive glazing units meet code requirements for fire-resistance-rated assembly and applicable safety glazing requirements. |
| 2. | Certificate on solar heat gain coefficient when value is specified. |
| C. | Manufacturer Warranty. |
| D. | Manufacturer's Literature and Data: |
| 1. | Glass, each kind required. |
| 2. | Elastic compound for metal sash glazing. |
| 3. | Glazing cushion. |
| 4. | Sealing compound. |
1.6 DELIVERY, STORAGE AND HANDLING:
| A. | Delivery: Schedule delivery to coincide with glazing schedules so minimum handling of crates is required. Do not open crates except as required for inspection for shipping damage. |
| B. | Storage: Store cases according to printed instructions on case, in areas least subject to traffic or falling objects. Keep storage area clean and dry. |
| C. | Handling: Unpack cases following printed instructions on case. Stack individual windows on edge leaned slightly against upright supports with separators between each. |
| D. | Protect laminated security glazing units against face and edge damage during entire sequence of fabrication, handling, and delivery to installation location. Provide protective covering on exposed faces of glazing plastics, and mark inside as "INTERIOR FACE" or "PROTECTED FACE": |
| 1. | Treat security glazing as fragile merchandise, and packaged and shipped in export wood cases with width end in upright position and blocked together in a mass. Storage and handling to comply with manufacturer's directions and as required to prevent edge damage or other damage to glazing resulting from effects of moisture, condensation, temperature changes, direct exposure to sun, other environmental conditions, and contact with chemical solvents. |
| 2. | Protect sealed-air-space insulating glazing units from exposure to abnormal pressure changes, as could result from substantial changes in altitude during delivery by air freight. Provide temporary breather tubes which do not nullify applicable warranties on hermetic seals. |
| 3. | Temporary protections: The glass front and polycarbonate back of glazing are to be temporarily protected with compatible, peelable, heat-resistant film which will be peeled for inspections and reapplied and finally removed after doors and windows are installed at destination. Since many adhesives will attack polycarbonate, the film used on exposed polycarbonate surfaces is to be approved and applied by manufacturer. |
| 4. | Edge protection: To cushion and protect glass clad, and polycarbonate edges from contamination or foreign matter, the four (4) edges are to be sealed the depth of glazing with continuous standardthickness thermoplastic rubber tape. Alternatively, continuous channel shaped extrusion of thermoplastic rubber are to be used, with flanges extending into face sides of glazing. |
| 5. | Protect "Constant Temperature" units including every unit where glass sheet is directly laminated to or directly sealed with metaltube type spacer bar to polycarbonate sheet, from exposures to ambient temperatures outside the range of 16 to 24 degrees C (60 to 75 degrees F), during the fabricating, handling, shipping, storing, installation, and subsequent protection of glazing. |
1.7 PROJECT CONDITIONS:
Field Measurements: Field measure openings before ordering tempered glass products to assure for proper fit of field measured products.
1.8 warranty:
A. Construction Warranty: Comply with the FAR clause 52.24621 “Warranty of Construction”.
1.9 APPLICABLE PUBLICATIONS:
A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only.
B. American Architectural Manufacturers Association (AAMA):
| 800 | Test Methods for Sealants |
| 810.1-77 | Expanded Cellular Glazing Tape |
| C. | American National Standards Institute (ANSI): |
| Z97.1-14 | Safety Glazing Material Used in Building Safety Performance Specifications and Methods of Test |
| D. | American Society of Civil Engineers (ASCE): |
| 7-10 | Wind Load Provisions |
| E. | ASTM International (ASTM): |
| C542-05(R2011) | Lock-Strip Gaskets |
| C716-06 | Installing Lock-Strip Gaskets and Infill Glazing Materials |
| C794-10 | Adhesion-in-Peel of Elastomeric Joint Sealants |
| C864-05(R2011) | Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers |
| C920-14a | Elastomeric Joint Sealants |
| C964-07(R2012) | Standard Guide for Lock-Strip Gasket Glazing |
| C1036-11(R2012) | Flat Glass |
| C1048-12 | Heat-Treated Flat Glass-Kind HS, Kind FT Coated and Uncoated Glass. |
| E84-14 | Surface Burning Characteristics of Building Materials |
| E119-14 | Standard Test Methods for Fire Test of Building Construction and Material |
| E1300-12a | Load Resistance of Glass in Buildings |
| E2355-10 | Test Method for Measuring the Visible Light Transmission Uniformity of an Absorptive Electrochromic Coating on a Glazing Surface |
| F1642-12 | Test Method for Glazing and Glazing Systems Subject to Airblast Loadings |
| F. | Code of Federal Regulations (CFR): |
| 16 CFR 1201-10 | Safety Standard for Architectural Glazing Materials |
| G. | Glass Association of North America (GANA): |
| 2010 Edition | GANA Glazing Manual |
| 2008 Edition | GANA Sealant Manual |
| 2009 Edition | GANA Laminated Glazing Reference Manual |
| 2010 Edition | GANA Protective Glazing Reference Manual |
| H. | International Code Council (ICC): |
| IBC | International Building Code |
I. Intertek Testing Services – Warnock Hersey (ITS-WHI)
| J. | National Fenestration Rating Council (NFRC) |
| K. | Safety Glazing Certification Council (SGCC) 2012: |
| Certified Products Directory (Issued Semi-Annually). | |
| L. | Underwriters Laboratories, Inc. (UL): |
| 9-08(R2009) | Fire Tests of Window Assemblies |
| 263-14 | Fire Tests of Building Construction and Materials |
| 752-11 | Bullet-Resisting Equipment. |
| M. | U.S. Veterans Administration: |
| Architectural Design Manual for VA Facilities (VASDM) |
N. Environmental Protection Agency (EPA):
40 CFR 59(2014) National Volatile Organic Compound Emission Standards for Consumer and Commercial Products
PART 2 - PRODUCT
2.1 GLASS:
| A. | Provide minimum thickness stated and as additionally required to meet performance requirements. |
| 1. | Provide minimum 6 mm (1/4 inch) thick glass units unless otherwise indicated. |
| B. | Obtain glass units from single source from single manufacturer for each glass type. |
2.2 HEAT-TREATED GLASS:
| A. | Roller Wave Limits for Heat-Treated Glass: Orient all roller wave distortion parallel to bottom surface of glazing, and provide units complying with the following limitations: |
| 1. | Measurement Parallel to Line: Maximum peak to valley 0.203 mm (0.008 inch). |
| 2. | Measurement Perpendicular to Line: Maximum 0.0254 mm (0.001 inch). |
| 3. | Bow/Warp: Maximum 50 percent of bow and warp allowed by ASTM C1048. |
| B. | Clear Tempered Glass: |
| 1. | ASTM C1048, Kind FT, Condition A, Type I, Class 1, Quality q3. |
2.3 GLAZING ACCESSORIES:
| A. | As required to supplement the accessories provided with the items to be glazed and to provide a complete installation. Ferrous metal accessories exposed in the finished work are to have a finish that will not corrode or stain while in service. Fire rated glazing to be installed with glazing accessories in accordance with the manufacturer’s installation instructions. |
| B. | Setting Blocks: ASTM C864: |
| 1. | Silicone type. |
2. Channel shape; having 6 mm (1/4 inch) internal depth.
| 3. | Shore A hardness of 80 to 90 Durometer. |
| 4. | Block lengths: 50 mm (2 inches) except 100 to 150 mm (4 to 6 inches) for insulating glass. |
| 5. | Block width: Approximately 1.6 mm (1/16 inch) less than the full width of the rabbet. |
| 6. | Block thickness: Minimum 4.8 mm (3/16 inch). Thickness sized for rabbet depth as required. |
| C. | Spacers: ASTM C864: |
| 1. | Channel shape having a 6 mm (1/4 inch) internal depth. |
| 2. | Flanges not less 2.4 mm (3/32 inch) thick and web 3 mm (1/8 inch) thick. |
| 3. | Lengths: 25 to 76 mm (1 to 3 inches). |
| 4. | Shore A hardness of 40 to 50 Durometer. |
| D. | Glazing Tapes: |
| 1. | Semisolid polymeric based closed cell material exhibiting pressuresensitive adhesion and withstanding exposure to sunlight, moisture, heat, cold, and aging. |
| 2. | Shape, size and degree of softness and strength suitable for use in glazing application to prevent water infiltration. |
3. Complying with AAMA 800 for the following types:
a. AAMA 810.1, Type 1, for glazing applications in which tape acts as the primary sealant.
b. AAMA 810.1, Type 2, for glazing applications in which tape is used in combination with a full bead of liquid sealant.
| E. | Spring Steel Spacer: Galvanized steel wire or strip designed to position glazing in channel or rabbeted sash with stops. |
| F. | Glazing Clips: Galvanized steel spring wire designed to hold glass in position in rabbeted sash without stops. |
| G. | Glazing Sealants: ASTM C920, silicone neutral cure: |
| 1. | Type S. |
| 2. | Class 25 or 50 as recommended by manufacturer for application. |
| 3. | Grade NS. |
| 4. | Shore A hardness of 25 to 30 Durometer. |
5. VOC Content: For sealants used inside the weatherproofing system, not more than 250 g/L or less when calculating according to 40 CFR
| H. | Neoprene, EPDM, or Vinyl Glazing Gasket: ASTM C864. |
| 1. | Channel shape; flanges may terminate above the glazing channel or flush with the top of the channel. |
| 2. | Designed for dry glazing. |
| I. | Color: |
| 1. | Color of glazing compounds, gaskets, and sealants used for aluminum color frames to match color of the finished aluminum and be nonstaining. |
| 2. | Color of other glazing compounds, gaskets, and sealants which will be exposed in the finished work and unpainted are to be black, gray, or neutral color. |
PART 3 - EXECUTION
3.1 EXAMINATION:
| A. | Verification of Conditions: |
| 1. | Examine openings for glass and glazing units; determine they are proper size; plumb; square; and level before installation is started. |
| 2. | Verify that glazing openings conform with details, dimensions and tolerances indicated on manufacturer is approved shop drawings. |
| B. | Review for conditions which may adversely affect glass and glazing unit installation, prior to commencement of installation. Do not proceed with installation until unsatisfactory conditions have been corrected. |
| C. | Verify that wash down of adjacent masonry is completed prior to erection of glass and glazing units. |
3.2 PREPARATION:
| A. | For sealant glazing, prepare glazing surfaces in accordance with GANA Sealant Manual. |
| B. | Determine glazing unit size and edge clearances by measuring the actual unit to receive the glazing. |
| C. | Shop fabricate and cut glass with smooth, straight edges of full size required by openings to provide GANA recommended edge clearances. |
| D. | Verify that components used are compatible. |
| E. | Clean and dry glazing surfaces. |
| F. | Prime surfaces scheduled to receive sealants, as determined by preconstruction sealant-substrate testing. |
3.3 INSTALLATION – GENERAL:
| A. | Install in accordance with GANA Glazing Manual, GANA Sealant Manual, IGMA TB-3001, and IGMA TM-3000 unless specified otherwise. |
| B. | Glaze in accordance with recommendations of glazing and framing manufacturers, and as required to meet the Performance Test Requirements specified in other applicable sections of specifications. |
| C. | Set glazing without bending, twisting, or forcing of units. |
| D. | Do not allow glass to rest on or contact any framing member. |
| E. | Glaze doors and operable sash, in a securely fixed or closed and locked position, until sealant, glazing compound, or putty has thoroughly set. |
| F. | Tempered Glass: Install with roller distortions in horizontal position unless otherwise directed. |
3.4 INSTALLATION WET/DRY METHOD (PREFORMED TAPE AND SEALANT)
| A. | Cut glazing tape to length and set against permanent stops, 5 mm (3/16 inch) below sight line. Seal corners by butting tape and dabbing with butyl sealant. |
| B. | Apply heel bead of butyl sealant along intersection of permanent stop with frame ensuring full perimeter seal between glass and frame to complete the continuity of the air and vapor seal. |
| C. | Place setting blocks at 1/4 points with edge block no more than 152 mm (6 inches) from corners. |
| D. | Rest glazing on setting blocks and push against tape and heel bead of sealant with sufficient pressure to achieve full contact at perimeter of pane or glass unit. |
| E. | Install removable stops, with spacer strips inserted between glazing and applied stops, 6 mm (1/4 inch) below sight line. Place glazing tape on glazing pane or unit with tape flush with sight line. |
| F. | Fill gap between glazing and stop with sealant to depth equal to bite of frame on glazing, but not more than 9 mm (3/8 inch) below sight line. Sealant type is to be compatible with glazing tape. |
| G. | Apply cap bead of sealant along void between the stop and the glazing, to uniform line, flush with sight line. Tool or wipe sealant surface smooth. |
3.5 INSTALLATION WET METHOD (SEALANT AND SEALANT):
| A. | Place setting blocks at 1/3 points and install glazing pane or unit. |
| B. | Install removable stops with glazing centered in space by inserting spacer shims both sides at 600 mm (24 inch) intervals, 6 mm (1/4 inch) below sight line. |
| C. | Fill gaps between glazing and stops with sealant to depth of bite on glazing, but not more than 9 mm (3/8 inch) below sight line to ensure full contact with glazing and continue the air and vapor seal. |
| D. | Apply sealant to uniform line, flush with sight line. Tool or wipe sealant surface smooth. |
3.6 INSTALLATION INTERIOR WET/DRY METHOD (TAPE AND SEALANT):
| A. | Cut glazing tape to length and install against permanent stops, projecting 1.6 mm (1/16 inch) above sight line. |
| B. | Place setting blocks at 1/3 points with edge block no more than 150 mm (6 inches) from corners. |
| C. | Rest glazing on setting blocks and push against tape to ensure full contact at perimeter of pane or unit. |
| D. | Install removable stops, spacer shims inserted between glazing and applied stops at 600 mm (24 inch) intervals, 6 mm (1/4 inch) below sight line. |
| E. | Fill gaps between pane and applied stop with sealant to depth equal to bite on glazing, to uniform and level line. Sealant type is to be compatible with glazing tape. |
| F. | Trim protruding tape edge. |
3.7 REPLACEMENT AND CLEANING:
| A. | Clean new glass surfaces removing temporary labels, paint spots, and defacement after approval by COR. |
| B. | Replace cracked, broken, and imperfect glass, or glass which has been installed improperly. |
| C. | Leave glass, putty, and other setting material in clean, whole, and acceptable condition. |
3.8 PROTECTION:
A. Protect finished surfaces from damage during erection, and after completion of work. Strippable plastic coatings on colored anodized finish are not acceptable.
3.9 MONOLITHIC GLASS SCHEDULE:
A. Glass Type for Doors: Clear fully tempered float glass.
1. Unit Thickness: 6 mm (0.23 inch).
2. Safety glazing label required.
- - - E N D - - - 08 80 00 - 1