Z1DA--667-22-4-1447-0009 - Project 667-18-104 Replace roof

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C25622R0086
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
238160 Roofing Contractors

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation is for project number 667-18-104 to replace roofs at various locations at the Overton Brooks VA Medical Center in Shreveport, Louisiana. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16 is seeking to replace approximately 30,000 square feet of roofing across multiple buildings. The period of performance is 200 calendar days from notice to proceed. Proposals will be evaluated based on management approach, qualifications, past performance, and price. The closing date for proposals is September 16, 2022.

This is a total Service-Disabled Veteran-Owned Small Business set-aside solicitation requiring offerors to be verified SDVOSBs. The place of performance is the Overton Brooks VA Medical Center. The estimated value is between $1-2 million. The NAICS code is 238160 and the PSC code is R499. The incumbent contractor is unknown. Infection control measures must be followed and construction phasing plans implemented to minimize disruptions to medical center operations during the 200-day performance period.

Notice text

2 versions

Update #2 · Latest ·

Request for Proposal to Construct

Replace Roof, Various Locations, Main Hospital

Project No. 667-18-104

Overton Brooks VA Medical Center, Shreveport, LA

* REVISED 08/10/2022

SCOPE:

Overton Brooks VAMC has a requirement to replace several roofs at various locations (approximately 30,000 SF) on the main hospital, building 1 Shreveport, LA. Roof sections include, but are not limited to, (A) Second Floor Clinical Addition, (B) Lobby, (C) Second Floor South, (D) 8-West, (E) 9-West, (F) Second Floor Canteen, (G) 12th Floor and (H) 10-North old Cooling tower area (Screen Wall). All asbestos containing material shall be abated. The existing roof systems shall be as built showing all roof penetrations, roof drainage piping, heating ventilation and air conditioning (HVAC) equipment, ductwork and appurtenances of any type. Any items or systems determined to be abandoned or no longer required shall be identified to be removed and capped or terminated. Access and continued function/operation of adjacent occupied spaces (above, below and beside) shall be considered within the construction phasing plan to minimize the overall impact and disruptions generated by the construction activities.

The C&A requirements do not apply, and that a Security Accreditation Package is not required.

PERIOD OF PERFORMANCE:

The delivery date for this contract shall be 200 days from Notice to Proceed.

CONTRACTOR SITE VISIT AND FIELD VERIFICATION PRIOR TO BIDDING:

Contractor shall be responsible for attending the Pre-Bid Site Visit prior to bidding to verify all existing conditions and take any necessary measurements required to adequately bid the project. If the Contractor chooses not to attend the Pre-Bid Site Visit, the Contractor may submit their bid at their own risk.

INFECTION CONTROL DURING CONSTRUCTION:

Contractor shall follow and comply with the established Infection Control Risk Assessment (ICRA) specific for the project. Contractor is responsible for dust control during demolition and during hauling operations.

DEMOLITION:

Contractor shall protect all adjacent areas of the hospital, especially windows and doors during all operations. Repairing any damage shall be the sole responsibility of the Contractor. If any damage is noticed prior to starting work which may be misconstrued as damage caused by the contractor, immediately notify the COR, and the damage shall be documented as existing conditions.

PHASING, NOISE, SMELLS, AND AFTER-HOURS WORK:

Work resulting in extensive noise or odor, shall be performed after hours or on weekends. Any required utility outages shall be scheduled at the convenience of the hospital, and potentially require after hours work or on weekends.

DELIVERIES:

Contractor shall coordinate material and equipment deliveries, storage, and handling requirements with COR.

FINAL CLEAN, PRE-FINAL & FINAL INSPECTIONS:

Once all work has been completed, the Contractor shall adequately clean the project site and request a Pre-Final Inspection. Upon completion of the pre-Final punch list items, the Contractor shall request a Final Inspection. Each of these inspections will be scheduled at the convenience of the hospital.

SUBMITTALS:

Provide: Email an electronic copy to the COR and each copy shall have a completed VA transmittal sheet attached.

Contractor shall provide submittal as detailed in the specifications and samples of all finishes showing the full range of available colors and options to be selected by the VA-ID and COR.

Update #1 ·

The purpose of this posting is to solicit project 667-18-104

Files

Show all 21

Notice history

Notice Type Posted
Z1DA--667-22-4-1447-0009 - Project 667-18-104 Replace roof 36C25622R0086 Award Award Notice
This notice Latest solicitation Solicitation
Z1DA--667-22-4-1447-0009 - Project 667-18-104 Replace roof Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB St. Louis Vamc St. Louis MO 63125 · NAICS 236220 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business
Z1DZ--Project No. 640A0-27-104, Replace Roof at Building 347 - Menlo Park Menlo Park, California 94025, United States · NAICS 236220 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
Z1DA-- 460-26-004 | Wilmington VAMC Roof Replacement | NCO 4 Construction East (VA-26-00029152) Wilmington, Delaware 19805, United States · NAICS 236220 Veterans Integrated Service Network 4 Service-Disabled Veteran-Owned Small Business
Modernize 6N Inpatient Restrooms (Swing for 3N) Shreveport, Louisiana 71101, United States · NAICS 236220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
C1DA--AE Replace Roofing 539-25-101 Cincinnati VA Medical Center 3200 Vine Street, United States · NAICS 541330 Veterans Integrated Service Network 10 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors