This document contains responses to requests for information regarding a federal contract opportunity to replace roofs at various locations of a main hospital. The solicitation is for project 667-18-104 to replace the roof under solicitation number 36C25622R0086 issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The responses clarify that all asbestos-containing materials are shown on the drawings and will require abatement. Walk pads are not needed for the abatement work. Roof flashings and sections on the east, west, and south sides as well as around columns in one area also require removal. Normal working hours are from 7 AM to 4:30 PM Monday through Friday, but off-hours work should be anticipated. Roof utilities shutdowns must be planned at least two weeks in advance, and means and methods are at the contractor's discretion provided the roofs do not leak during construction. Anchors for the new roofing materials must be submitted for approval.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHASHRShaffE Typewritten Text Sheets AB 101 & AB 102 Correctly Define
VHASHRShaffE Typewritten Text the ACM scope of work
VHASHRShaffE Typewritten Text 7AM to 4:30 PM M-F are normal working
VHASHRShaffE Typewritten Text hours. But anticipate off-hours work.
VHASHRShaffE Typewritten Text CO to provide
VHASHRShaffE Typewritten Text All ACM is
VHASHRShaffE Typewritten Text shown on AB 102.
VHASHRShaffE Typewritten Text Walk pads are not required during
VHASHRShaffE Typewritten Text abatement
VHASHRShaffE
No ACM in this area.
VHASHRShaffE
No walk pads required during abatement
VHASHRShaffE Typewritten Text As shown on AB101 &AB 102
VHASHRShaffE Typewritten Text flashings
VHASHRShaffE Typewritten Text associated with ACM are to be removed
VHASHRShaffE Typewritten Text
VHASHRShaffE Typewritten Text Additionally remove the E. W. &S sides &
VHASHRShaffE Typewritten Text around the columns of Area H
VHASHRShaffE Typewritten Text Roof Area A is detailed on Sheet A102, VHASHRShaffE Typewritten Text Note F.
VHASHRShaffE Typewritten Text Submit anchors for approval
VHASHRShaffE Typewritten Text See Below
VHASHRShaffE Typewritten Text RFI # 7 All roofs must be prevented from leaking during construction. Means & methods
VHASHRShaffE Typewritten Text are Contractors discression. Roof utilities shut downs must be pre-planned &
VHASHRShaffE scheduled at least 2 weeks in advance