8"
MIN
T
B
C
A
P I P
E
O
D
C = PIPE OD X 4
(SEE NOTE 2)
LOCATION PT AND
INVERT ELEVATION
CL PIPE
D
RIP RAP (SEE NOTE 4)
FABRIC FILTER GEOTEXTILE
TOE WALL SEE NOTE 1 FOR
DEPTH
FINAL GRADE
PLAN
SECTION A-A
RCP FLARED END SECTION
(DETAIL A5)
#5 @ 12" E.W.
F
T
CL PIPE
E
C
A
L
E
PIPE DIAM.
10 48 78
10 48 78
A C L E
DIMENSIONS IN INCHES
(INCHES)
REINFORCED CONCRETE ROUND PIPE
6 48 73
4 48 72
NOTES:
1. TOE WALL (G) SHALL BE 18-INCHES BELOW BOTTOM OF END SECTION
ON UPSTREAM END AND 24-INCH ON DOWNSTREAM END.
2. WHEN PIPE CENTERLINE AND DITCH CENTERLINE INTERSECTION IS
APPROX. PERPENDICULAR, EXTEND RIPRAP UP SIDE OPPOSITE PIPE
DISCHARGE TO HEIGHT LEVEL WITH TOP OF PIPE.
3. PLACE RIP RAP AT ALL END SECTIONS AND CULVERT HEADWALLS.
4. D
RIP RAP SHALL BE HARD AND DURABLE ROCK CONSISTING OF
6-INCH MATERIAL.
NOTES:
1. DIMENSIONS OF END SECTIONS MAY VARY SLIGHTLY FROM THOSE SHOWN ON THE TABLES
DUE TO DIFFERENT MANUFACTURER'S VARIATIONS.
2. CONCRETE PIPE JOINT FASTENERS, WHERE SHOWN ON THE DRAWINGS, SHALL BE INSTALLED
SO THAT A MINIMUM OF 15 LINEAR FEET OF THE OUTLET END OF THE PIPE ARE
MECHANICALLY LOCKED TOGETHER. END SECTION LENGTHS SHALL BE INCLUDED IN THE 15
LF REQUIREMENT.
3. FOR RIP RAP INFORMATION SEE DETAIL A1 ON THIS SHEET.
M I N
SCALE: NTS
END SECTION FOR REINFORCED
CONCRETE CIRCULAR PIPE (30" OR LESS)
A5
SCALE: NTS
FLARED END SECTION
A1
CU502
A
A
CU502
A
A
SECTION A-A END VIEW
PLAN
A
P
I P
E
O
D
X
H
WATER LINE
WATER LINE
SEWER LINE
20.00'
20.00'
M
I N
PROPOSED OR
EXISTING GRADE
NOTES:
1. ALL SANITARY SEWER LINES THAT CROSS LESS THAN 24 INCHES ABOVE OR BELOW WATER
MAINS OR SERVICE LINES SHALL BE SEAMLESS HDPE PIPE FOR 10 FEET EACH SIDE OF THE
CENTERLINE OF THE CROSSING. SEWER PIPE SHALL BE TESTED IN ACCORDANCE WITH THE
SPECIFICATIONS FOR PRESSURE PIPE. CONTRACTOR MAY LOWER WATER LINES TO CLEAR
MORE THAN 24 INCHES BELOW THE SEWER LINE OR RAISE THEM TO CLEAR MORE THAN 24
INCHES ABOVE THE SEWER LINE BUT MUST MAINTAIN THE MINIMUM BURY DEPTH/COVER OF 42
INCHES ON ALL WATER MAINS AND SERVICE LINES AND 42 INCHES FOR ALL FIREWATER MAINS.
2. LENGTH OF EXTENSION OF PIPE AND RESTRAINED JOINTS SHALL BE IN ACCORDANCE WITH THE
SPECIFICATIONS AND DRAWINGS.
3. A BORED CROSSING MAY BE REQUIRED BY THE CONTRACTOR.
SEE NOTE 1 FOR WATER LINES
ABOVE OR BELOW SEWER LINES.
45° ELBOW
(TYP)
SCALE: NTS
WATER/SEWER LINE CROSSING DETAIL
B1
GRAVITY BLOCK
THRUST BLOCK - SEE
DETAIL A1 ON CU501
8" 45° PLASTIC BEND
8" DIA. CORRUGATED HDPE ROOF DRAIN
PLASTIC STORM
DRAIN PIPE
BUILDING
WALL
DOWNSPOUT
FOOTING
FINISH GRADE
CAST IRON DOWNSPOUT SHOE WITH
BRASS CLEANOUT (NEENAH
R-4929-OFFSET MODEL OR APPROVED
EQUAL)
STORM DRAIN PIPE
SEE UTILITY PLANS
8" 45° PLASTIC BEND
2 EACH 8" 45° PLASTIC ELBOWS
8" DIA. PLASTIC PIPE
CAST IRON MANUFACTURER'S
STANDARD TRANSITIONAL
COUPLING
8"x8" 45°
PLASTIC
WYE
8" DIA. PLASTIC ROOF DRAIN PIPE
VARIES - SEE PLANS
1%
ECAST IRON COVER AND
FRAME (NEENAH R-1792-TYPE
C OR APPROVED EQUAL)
FINISHED GRADE
8" DIA. PLASTIC PIPE
2 EACH 45°
PLASTIC BENDS
CLEANOUT
8" 45° PLASTIC WYE
PLASTIC STORM
DRAIN PIPE
8" DIA. PLASTIC
ROOF DRAIN PIPE
8" 45° PLASTIC BEND
FROM
BLDG
F L O
W
PLAN
PROFILE
STORM DRAIN
SECTION A-A
CONCRETE PAD IN
UNPAVED AREAS
#10 BARS ALL
AROUND (6" LAP)
DOWNSPOUT
24"
M I N
48" MIN ABOVE
GRADE
NOTE:
1. SEE UTILITY PLANS FOR DEMARCATION OF
ROOF DRAINS.
SCALE: NTS
ROOF DRAIN AND CLEANOUT
C3S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
no. date descriptionby ckd
J
H
G
F
E
D
C
B
A
C O
P Y
R I G
H T
B
U R
N S
M c D
O N
N E
L L
E
N G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
A
M
180TH FIGHTER WING
OHIO AIR NATIONAL GUARD
TOLEDO EXPRESS AIRPORT
SWANTON, OHIO
180th Fighter Wing
Toledo Express Airport, OH
9400 WARD PARKWAY
KANSAS CITY, MO 64114
(816) 333-9400
REVISIONS
K
Construct ACA Shelters
1 1098765432
WYTD079031 W9133L-15-D-0003-9M03
UTILITY DETAILS SHEET 3 OF 5
CU502 1
UTILITY DETAILS SHEET 3 OF 5
02/12/18 C. FRANZEN
A. DORMAN C. STEWART
\\BMCD\DFS\CLIENTS\ANF\USNGB\ANG\OH\102134_OHANGALRTSHLTB\DESIGN\CIVIL\SHEETS\102134CU500.DWG 11/15/2018 10:57 AM CFRANZEN
AMENDMENT 0002ABDCWF11/16/181