Draw_S-101_and_S-102_foundation.pdf

PDF 496 KB Posted

Attached to
Aircraft Alert Shelters Federal contract opportunity
Solicitation number
W9136419B8001
Issued by
Department of the Army Ohio Army National Guard

About this file

Drawing S-101, S-102

View the file

Other files for this federal contract opportunity

Other files attached to Aircraft Alert Shelters, newest first.
File Type Posted
Bid_opening_attendance.pdf PDF
1.Abstract_of_offers-Shelter.pdf PDF
PROJECT_TOC_updated_11-29-18.pdf PDF
W9136419B8001-0004_ACA_Shelter_Amend_04.pdf PDF
Draw_S005.pdf PDF
Arktite-200a-plugs-receptacles-connectors.pdf PDF
Sec_32_13_14.13_concrete.pdf PDF
Draw_EP101_601,_ES106_401.pdf PDF
Draw_A-701_Locked.pdf PDF
Draw_Electrical_-_Set-11.pdf PDF
MNS_Klaxon_asbuilt.pdf PDF
Draw_CP101_JOINT_LAYOUT_GRID_1.pdf PDF
Shelter_Phone_info.pdf PDF
W9136419B8001-0003_ACA_Shelter_Amend_03.pdf PDF
Specs_07_92_00.pdf PDF
W9136419B8001-0002_ACA_Shelter_Amend_02.pdf PDF
Specs_07_27_10.00_10.pdf PDF
Draw_102134_Arch_Amend_2_A_set_Nov_15_2018.pdf PDF
Specs_07_61_14.00_20.pdf PDF
Temp_Shelter_HEATING_SYSTEM.doc DOC document
Draw_102134_S_set.pdf PDF
Specs_13_34_19.pdf PDF
Specs_05_50_13.pdf PDF
Draw_CU504_UTILITY_DETAILS_SHEET_5_OF_5.pdf PDF
Draw_CU502_UTILITY_DETAILS_SHEET_3_OF_5.pdf PDF
Temp_SHELTERS_SPECS..doc DOC document
Temp_Shelter_Top_Plate_Layout.pdf PDF
Draw_CG110_EROSION_CONTROL_PLAN.pdf PDF
W9136419B8001-0001_ACA_Shelter_Amend_01.pdf PDF
Spec_26_35_43_converters.pdf PDF
Draw_A-601_door_schedule.pdf PDF
Draw_CG500_EROSION_CONTROL_DETAILS.pdf PDF
Pre-Bid_Conference_19B8001.pptx PPTX presentation
Shelter_PreBid_attendance.pdf PDF
Bid_Sched_B3.pdf PDF
A2.SHELTER_DWGS_Oct_2018-1.pdf PDF
W9136419B8001_ACA_Shelter.pdf PDF
A4.Shelter_Specs_VOL2_OCT_2018.pdf PDF
A1.01800_Base_Enviromental.pdf PDF
A3.Shelter_Specs_VOL1_OCT_2018.pdf PDF
Shelter_RFI_template.doc DOC document
Show all 41

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

2 3

C

E

D

B

73' - 0" 74' - 10"

/2

/2

F4

S-201

A1

S-200

A6

S-200

G4

S-200

G7

S-200

F2 F7

F3

F4 F5

F8

F1

F5

F3 F4F5

F2

F6

F7

G4

S-200

A6

S-200

20'-0" TO GRID 4

M A

T C

H L

IN

E

S E

E S

-1

NOTE 8, TYP

HANGAR BAY

PERIMETER SLAB

NOTE 10, TYP

/1

/1

/1

/1

/1

7' - 6" 14' - 6" 14' - 6" 14' - 6" 14' - 6" 7' - 6" 7' - 6" 14' - 11 1/2" 14' - 11 1/2" 14' - 11 1/2" 14' - 11 1/2" 7' - 6"

X X

X X

X X

X X

X X

X X

X X

NOTE 9

T O

C E

L

F7

S-201

X X

X X

X X

HANGAR BAY SLAB

SEE NOTE 11, TYP

SEE NOTE 13,

TYP

A1

S-201

TYP @

DOORWAY

T O

C E

L

/4

C T

J -2

C T

J -2

C J -2

CTJ-2

CTJ-2

CJ-2

CTJ-2

CTJ-2

CTJ-2

CTJ-2

C T

J -2

C T

J -2

C J -2

CTJ-2

CTJ-2

CJ-2

CTJ-2

CTJ-2

CTJ-2

CTJ-2

CJ-1 CJ-1 CJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

TOC EL 100'-0"

TOC EL 99'-6 1/4"

F1

S-201

HANGAR BAY SLAB

SEE NOTE 11, TYP

SEE NOTE 14

SEE NOTE 14

HANGAR BAY

PERIMETER SLAB

NOTE 10, TYP

HANGAR BAY

PERIMETER SLAB

NOTE 10, TYP

F7

S-201

SIM

EDGE SLAB PANELS AT

HANGAR BAY SLAB

NOTE 15, TYP ALL EDGES

ALL BAYS.

/2

NOTE 16

NOTE 10

F4

S-201

NOTE 17

A4

S-200

A4

S-200

F1

S-201 STRAIGHT COL W/10" DEPTH

RESTRICTION UP TO 10'-0"

1' - 6"CL FTG

1' - 6"

CL FTG

F6

WARP SLAB AT

SECOND STAGE

CONCRETE POUR,

TYP GRID A

S c a le

F o r

M ic ro fi lm in g

In c h e s

M ill im e te rs date detailed checkeddesigned project contract rev.drawing file

no. date descriptionby ckd

J

H

G

F

E

D

C

B

A

C O

P Y

R

IG

H T

B

U R

N S

M

C D

O N

N E

L L E

N G

IN

E

E R

IN

G

C O

M P

A N

Y

IN

C

W9133L-15-D-0003-9M03

180TH FIGHTER WING

OHIO AIR NATIONAL GUARD

TOLEDO EXPRESS AIRPORT

SWANTON, OHIO

180th Fighter Wing Toledo Express Airport, OH

9400 WARD PARKWAY

KANSAS CITY, MO 64114

(816) 333-9400

REVISIONS

WYTD079031

K

Construct ACA Shelters

KEYPLAN

A

E

1 4 6

A B

N

1 1098765432

/7 /2

:4

:4

A

M

102134_S_CENTRAL

S-101

FOUNDATION AND SLAB PLAN A

19 MAR 2018

K. SMITH J. SCHMIDT

J. DELGADO

SCALE: 1/8" = 1'-0"C1

FOUNDATION - AREA A

0 4' 8' 16'

NOTES:

1. FOR GENERAL NOTES, SEE SHEET

S-001 AND S-002. FOR ABBREVATIONS AND

LEGENED SEE SHEET S-003. FOR

TYPICAL CONCRETE DETAILS, SEE

SHEETS S-004 TO S-006,

FOR STEEL DETAILS, SEE SHEET S-007.

2. EXCAVATION, FILL, BACKFILL,

FOUNDATION, AND SLAB BASE SHALL

BE IN ACCORDANCE WITH THE

SPECIFICATIONS.

3. BOTTOM OF FOUNDATIONS SHALL BE MIN

3'-6" BELOW REFERENCE FINISH FLOOR

ELEVATION OF 100'-0" UNO.

4. F-X INDICATES FOUNDATION TYPE, SEE

FOUNDATION SCHEDULE ON SHEET

S-201 FOR SIZE AND REINFORCING. TOP OF

FOOTING EL = 98'-0''. FOOTING IS CENTERED

GRID UNO.

5. METAL BUILDING ANCHOR BOLTS:

a. CONFIRM ANCHOR BOLT

QUANTITY AND DIAMETER WITH

FINAL METAL BUILDING DESIGN

DRAWINGS FOR EACH COLUMN.

b. ANCHOR BOLT PATTERN AND

LAYOUT TO BE DETERMINED BY

METAL BUILDING DESIGNER.

c. ANCHOR BOLTS TO BE TYPE II

PER TYPICAL BOLT DETAIL.

d. ANCHOR BOLT MATERIAL IS TO

BE ASTM F1554 GRADE 36.

6. XX INDICATES BRACED BAY LOCATIONS.

7. 10'-0" HIGH REINFORCED CMU

WAINSCOTT WALL, SEE ARCHITECTURAL

PLANS FOR BLOCK TYPES AND

LOCATIONS.

8. SLAB CONTRACTION AND

CONSTRUCTION JOINTS PER TYPICAL

DETAILS. CONTRACTOR TO SUBMIT

FINAL JOINTING PLAN FOR REVIEW.

9. EQUIPMENT PAD PER S-005 FOR FIRE

PROTECTION EQUIPMENT. LOCATION

AND DIMENSIONS TO BE COORDINATED

DURING CONSTRUCTION WITH ACTUAL

EQUIPMENT PROVIDED.

10.SLAB ON GRADE AROUND PERIMETER

OF HANGAR BAYS AND AT MECH/ELEC/FP

ROOMS SHALL BE 8 INCH THICK CONCRETE

SLAB REINFORCED WITH #4 BARS @ 16"

ON CENTER EACH WAY, TOP ON 6" THICK

COMPACTED DRAINGAGE LAYER ON 15MIL

VAPOR BARRIER.

11.SLAB ON GRADE AT HANGAR BAYS SHALL

BE 14.5 INCH THICK CONCRETE SLAB ON 6"

THICK COMPACTED DRAINGAGE LAYER ON

15MIL VAPOR BARRIER

12.SEE ARCH AND CIVIL DWGS FOR

LOCATIONS OF OPENING, SIDEWALKS,

STOOPS AND PAVING.

13.SLAB JOINTS, SEE S-005. JOINT MAX

SPACING 15'-0" OC.

14.SLAB DOWELS @ 20" OC, PLAN HORIZ,

SEE S-005.

15. REINFORCE SLAB WITH #4 BARS AT 12"OC.

16. WARP SLAB AT DOOR TO MATCH

ELEVATIONS.

17. STEP FOOTING AT UNDERGROUND PIPING

PER TYP DET ON S-006 AS REQUIRED.

N

CAPTIVATION REQUIREMENTS

HIGH NOISE LEVEL, CHARACTERISTIC OF JET ENGINES, PRODUCES HIGH VIBRATING FORCES WHICH MAY RESULT IN THE LOOSENNG OF SCREWS, BOLTS, NUTS AND FASTENERS. THE HIGH VOLUME OF AIR MOVEMENT CAN DRAW THESE LOOSENED ITEMS INTO JET ENGINES (POSSIBLY DESTROYING THE ENGINE OR INJURING PERSONNEL).

CAPTIVATION METHODS ARE NECESSARY TO PREVENT THESE ITEMS FROM LOOSENING. THE REQUIREMENTS ARE

AS FOLLOWS:

1) THREADED PARTS OF INTERIOR EXPOSED BOLTED OR SCREWED CONNECTIONS AND FASTENERS FOR THE BUILDING SIDING, ANCHOR BOLTS, EQUIPMENT AND ACCESSORIES IN THE ALERT SHELTER SHALL BE

COATED WITH THE GE SILICONE RTV 108 OR APPROVED EQUAL.

2) THREADED CONNECTIONS OF FITTINGS OR DEVICES OF PIPING AND TUBING SYSTEMS, SUCH AS COUPLINGS, NIPPLES, UNIONS, CAPS, PLUGS, ETC. SHALL BE COATED WITH THE GE SILICONE RTV 108 OR APPROVED

EQUAL.

3) THREADED CONDUIT CONNECTIONS AT COUPLINGS, FIXTURES, JUNCTION BOXES, DEVICES, ETC. SHALL BE

COATED WITH THE GE SILICONE RTV 108 OR APPROVED EQUAL.

4) THREADED PARTS OF CONNECTIONS OF HANGERS AND SUPPORTS FOR EQUIPMENT, PIPING AND CONDUIT

SHALL BE COATED WITH GE SILICONE RTV 108 OR APPROVED EQUAL.

1 11/07/18 JMD KAS AMENDMENT 0001

A

C

E

D

B

74' - 10" 73' - 0"

/2

/2

F3

F3

F8

F3

F3

G1

S-200

A4

S-200

A6

S-200

G4

S-200

OPP

HAND

OPP

HAND

20'-0" TO GRID 3

F1

F4

F6

F4

F6

F1

F1

F4

F1

F4

A6

S-200

G4

S-200

OPP

HAND

OPP

HAND

M A

T C

H L

IN

E

S E

E S

-1

F4

S-201

F4

S-201

NOTE 8, TYP

NOTE 9

/1

/1

/1

/1

/1

8' - 8" 7' - 6" 14' - 8" 14' - 6" 14' - 6" 14' - 4"14' - 8" 14' - 8" 14' - 8" 14' - 8" 7' - 6"

X X

X X

X X

X X

X X

X X

T O

C E

L

X X

SEE NOTE 13,

TYP

T O

C E

L

/4

HANGAR BAY

PERIMETER SLAB

NOTE 10, TYP

C T

J -2

C T

J -2

C J -2

CTJ-2

CTJ-2

CJ-2

CTJ-2

CTJ-2

CTJ-2

CTJ-2

C T

J -2

C J -2

CTJ-2

CJ-2

CTJ-2

CTJ-2

CTJ-2

CTJ-2

CJ-1CJ-1CJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

X X

C T

J -2

CTJ-2

CJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

CTJ-1

7' - 6"

TOC EL 100'-0"

TOC EL 99'-6 1/4"

F7

S-201

SEE NOTE 14

SEE NOTE 14

HANGAR BAY SLAB

SEE NOTE 11, TYP

HANGAR BAY SLAB

SEE NOTE 11, TYP

A1

S-201

SIM

HANGAR BAY

PERIMETER SLAB

NOTE 10, TYP

HANGAR BAY

PERIMETER SLAB

NOTE 10, TYP

OPP

HAND

F7

S-201

EDGE SLAB PANELS AT

HANGAR BAY SLAB

NOTE 15, TYP ALL EDGES

ALL BAYS.

NOTE 10

NOTE 17

A4

S-200

F1

S-201

F1

S-201

/2

CL FTG

1' - 2" 1' - 0"

CL FTG

1' - 2"

NOTE 16

WARP SLAB AT

SECOND STAGE

CONCRETE POUR,

TYP GRID A

1' - 0"

CL FTG

S c a le

F o r

M ic ro fi lm in g

In c h e s

M ill im e te rs date detailed checkeddesigned project contract rev.drawing file

no. date descriptionby ckd

J

H

G

F

E

D

C

B

A

C O

P Y

R

IG

H T

B

U R

N S

M

C D

O N

N E

L L E

N G

IN

E

E R

IN

G

C O

M P

A N

Y

IN

C

W9133L-15-D-0003-9M03

180TH FIGHTER WING

OHIO AIR NATIONAL GUARD

TOLEDO EXPRESS AIRPORT

SWANTON, OHIO

180th Fighter Wing Toledo Express Airport, OH

9400 WARD PARKWAY

KANSAS CITY, MO 64114

(816) 333-9400

REVISIONS

WYTD079031

K

Construct ACA Shelters

KEYPLAN

A

E

1 4 6

A B

N

1 1098765432

/7 /2

:4

:4

A

M

102134_S_CENTRAL

S-102

FOUNDATION AND SLAB PLAN B

19 MAR 2018

K. SMITH J. SCHMIDT

J. DELGADO

SCALE: 1/8" = 1'-0"C1

FOUNDATION - AREA B

0 4' 8' 16'

GENERAL NOTES

FOR GENERAL NOTES, SEE SHEET

S-001 AND S-002. FOR ABBREVATIONS AND

LEGENED SEE SHEET S-003. FOR

TYPICAL CONCRETE DETAILS, SEE

SHEETS S-004 TO S-006,

FOR STEEL DETAILS, SEE SHEET S-007.

2. EXCAVATION, FILL, BACKFILL,

FOUNDATION, AND SLAB BASE SHALL

BE IN ACCORDANCE WITH THE

SPECIFICATIONS.

3. BOTTOM OF FOUNDATIONS SHALL BE MIN

3'-6" BELOW REFERENCE FINISH FLOOR

ELEVATION OF 100'-0" UNO.

4. F-X INDICATES FOUNDATION TYPE, SEE

FOUNDATION SCHEDULE ON SHEET

S-201 FOR SIZE AND REINFORCING. TOP OF

FOOTING EL = 98'-0''. FOOTING IS CENTERED

GRID UNO.

5. METAL BUILDING ANCHOR BOLTS:

a. CONFIRM ANCHOR BOLT

QUANTITY AND DIAMETER WITH

FINAL METAL BUILDING DESIGN

DRAWINGS FOR EACH COLUMN.

b. ANCHOR BOLT PATTERN AND

LAYOUT TO BE DETERMINED BY

METAL BUILDING DESIGNER.

c. ANCHOR BOLTS TO BE TYPE II

PER TYPICAL BOLT DETAIL.

d. ANCHOR BOLT MATERIAL IS TO

BE ASTM F1554 GRADE 36.

6. XX INDICATES BRACED BAY LOCATIONS.

7. 10'-0" HIGH REINFORCED CMU

WAINSCOTT WALL, SEE ARCHITECTURAL

PLANS FOR BLOCK TYPES AND

LOCATIONS.

8. SLAB CONTRACTION AND

CONSTRUCTION JOINTS PER TYPICAL

DETAILS. CONTRACTOR TO SUBMIT

FINAL JOINTING PLAN FOR REVIEW.

9. EQUIPMENT PAD PER S-005 FOR FIRE

PROTECTION EQUIPMENT. LOCATION

AND DIMENSIONS TO BE COORDINATED

DURING CONSTRUCTION WITH ACTUAL

EQUIPMENT PROVIDED.

10.SLAB ON GRADE AROUND PERIMETER

OF HANGAR BAYS AND AT MECH/ELEC/FP

ROOMS SHALL BE 8 INCH THICK CONCRETE

SLAB REINFORCED WITH #4 BARS @ 16"

ON CENTER EACH WAY, TOP ON 6" THICK

COMPACTED DRAINGAGE LAYER ON 15MIL

VAPOR BARRIER.

11.SLAB ON GRADE AT HANGAR BAYS SHALL

BE 14.5 INCH THICK CONCRETE SLAB ON 6"

THICK COMPACTED DRAINGAGE LAYER ON

15MIL VAPOR BARRIER

12.SEE ARCH AND CIVIL DWGS FOR

LOCATIONS OF OPENING, SIDEWALKS,

STOOPS AND PAVING.

13.SLAB JOINTS, SEE S-005. JOINT MAX

SPACING 15'-0" OC.

14.SLAB DOWELS @ 20" OC, PLAN HORIZ,

SEE S-005.

15. REINFORCE SLAB WITH #4 BARS AT 12"OC.

16. WARP SLAB AT DOOR TO MATCH

ELEVATIONS.

17. STEP FOOTING AT UNDERGROUND PIPING

PER TYP DET ON S-006 AS REQUIRED.

N

CAPTIVATION REQUIREMENTS

HIGH NOISE LEVEL, CHARACTERISTIC OF JET ENGINES, PRODUCES HIGH VIBRATING FORCES WHICH MAY RESULT IN THE LOOSENNG OF SCREWS, BOLTS, NUTS AND FASTENERS. THE HIGH VOLUME OF AIR MOVEMENT CAN DRAW THESE LOOSENED ITEMS INTO JET ENGINES (POSSIBLY DESTROYING THE ENGINE OR INJURING PERSONNEL).

CAPTIVATION METHODS ARE NECESSARY TO PREVENT THESE ITEMS FROM LOOSENING. THE REQUIREMENTS ARE

AS FOLLOWS:

1) THREADED PARTS OF INTERIOR EXPOSED BOLTED OR SCREWED CONNECTIONS AND FASTENERS FOR THE BUILDING SIDING, ANCHOR BOLTS, EQUIPMENT AND ACCESSORIES IN THE ALERT SHELTER SHALL BE

COATED WITH THE GE SILICONE RTV 108 OR APPROVED EQUAL.

2) THREADED CONNECTIONS OF FITTINGS OR DEVICES OF PIPING AND TUBING SYSTEMS, SUCH AS COUPLINGS, NIPPLES, UNIONS, CAPS, PLUGS, ETC. SHALL BE COATED WITH THE GE SILICONE RTV 108 OR APPROVED

EQUAL.

3) THREADED CONDUIT CONNECTIONS AT COUPLINGS, FIXTURES, JUNCTION BOXES, DEVICES, ETC. SHALL BE

COATED WITH THE GE SILICONE RTV 108 OR APPROVED EQUAL.

4) THREADED PARTS OF CONNECTIONS OF HANGERS AND SUPPORTS FOR EQUIPMENT, PIPING AND CONDUIT

SHALL BE COATED WITH GE SILICONE RTV 108 OR APPROVED EQUAL.