TYPICAL SLAB ON GRADE CONTRACTION
SLAB JOINT
CTJ-1
NOT TO SCALE
SLAB REINFORCMENT*
15 MIL VAPOR BARRIER
6" CAPILLARY
WATER BARRIER.
SEE SPEC 32 11 23.23
H
S-005
TYPICAL HANGAR FLOOR CONTRACTION
SLAB JOINT
CTJ-2
NOT TO SCALE
15 MIL VAPOR BARRIER
6" CAPILLARY
WATER
BARRIER. SEE
SPEC 32 11 23.23
H
S-005
*DO NOT EXTEND REINFORCEMENT THROUGH JOINT
H /4
(SAWED)
1/8 " TO 1/4" SEALED
1 1/4" MAX
SAME PLACEMENT
C L R
/2
TYP CONCRETE STEM WALL CONTROL JOINT
NOT TO SCALE
STOP ALTERNATE
HORIZONTAL REBAR
AT CONTROL JOINT
NOTE:
PROVIDE CONTROL JOINTS IN CONCRETE STEM WALLS AT 20'-0" MAX.
MAXIMUM LENGTH WALL POUR BETWEEN CONSTRUCTION JOINTS 100'-0"
3/4
/8
INITIAL SAWCUT
BACK UP ROD
OR POLYETHYLENE
STRIP
SEALANT .
T
3/8"
NOTES:
1. DEPTH OF INITIAL SAWCUT
a. 1/4" SLAB THICKNESS +/- 1/2" FOR SLABS LESS THAN 12 INCHES.
b. 3 INCHES FOR SLABS 12-18INCHES.
c. 1.6 SLAB THICKNESS FOR SLABS MORE THAN 18 INCHES.
d. DIAMETER OF BACKER MATERIAL = JOINT WIDTH + 1/8 INCH
2. DEPTH OF SEALANT AS REQ'D BY SEALANT MANUFACTURER
3. * TOP OF SEALANT TO BE 1/4" TO 1/16" BELOW TOP OF SLAB
BUTTED JOINT
BACK UP ROD
OR POLYETHYLENE
STRIP
SEALANT
SLAB SURFACE
SLAB SURFACE
*INITIAL SAWCUT 1/8"
CRACK
CONTRACTION JOINT CONSTRUCTION JOINT
D
D
.3/8"
CJ-1
TYPICAL SLAB ON GRADE CONSTRUCTION
SLAB JOINT
NOT TO SCALE
4" CAPILLARY
WATER
BARRIER. SEE
SPEC 32 11 23.23
15 MIL VAPOR BARRIER
H
SLAB REINFORCEMENT*
CJ-2
TYPICAL HANGAR FLOOR CONSTRUCTION
SLAB JOINT
NOT TO SCALE
4" CAPILLARY
WATER
BARRIER. SEE
SPEC 32 11 23.23
1 1/4" DIA X 15" DOWELS-
OIL ONE END
15 MIL VAPOR BARRIER
H
S-005
H /2
*DO NOT EXTEND REINFORCEMENT THROUGH JOINT
1 1/2" KEYED JOINT
H /3
H /3
H /3
C L R
/2
CONSTRUCTION JOINT
PROVIDE SEALANT AT HANGAR
BAY
TYPICAL CONSTRUCTION JOINT
NOT TO SCALE
SEE SECTIONS
FOR FOOTING
DETAILS
. LAP SPLICE
NOT TO SCALE
1. PROVIDE EP-1 FOR ALL INT EQPT AND FOR EXT EQPT ON CONC
PAVEMENT. SEE OTHER DISCIPLINE DRAWINGS FOR EQPT LOCATIONS.
2. EQPT ANCHOR BOLTS SHALL BE STANDARD TYPE II BOLTS,
UNLESS OTHERWISE RECOMMENDED BY EQPT MFR.
3. EQPT SHALL BE GROUTED IN PLACE W/ NON-SHRINK GROUT UNLESS
OTHERWISE RECOMMENDED BY EQPT MFR.
4. FOR EP-1 ONLY:
A. PROVIDE NUMBER OF DOWELS TO MATCH TOTAL CROSS-
SECTIONAL AREA OF ANCHOR BOLTS, EQUALLY SPACED AROUND
PAD, EXCEPT THAT SPACING OF DOWELS SHALL NOT EXCEED 12".
B. IF FLOOR SLAB OR PAVEMENT IS EXISTING OR CONSTRUCTED
BEFORE DOWELS ARE PLACED, DOWELS SHALL BE EPOXY
GROUTED INTO FLOOR SLAB OR PAVEMENT W/ 4 1/2" EMBED.
C. HEIGHT OF PAD ABOVE SURROUNDING FLOOR SLAB OR PAVEMENT
SHALL BE 4" MIN FOR PADS W/ 1" DIA OR SMALLER ANCHOR BOLTS,
OR 6" MIN FOR PADS W/ ANCHOR BOLTS LARGER THAN 1" DIA.
0' - 5"2" MIN TO EDGE
OF EQPT BASE
BUSH-HAMMER ROUGH
UNDER AREA OF PAD AND
APPLY BONDING
COMPOUND
#4 @ 12" EW TOP
#4 DOWELS, SEE
NOTES 4A & 4B
N O
T E
C
BASE PLATE, ANCHOR BOLTS,
AND GROUT PER EQPT SUPPLIER
NOTES:
INTERIOR EQUIPMENT PAD (EP-1)
SECOND STAGE
CONCRETE PLACEMENT
CONSTRUCTION OR
CONTRACTION JOINT
SEALED ISOLATION
JOINT DISCONTINUE
REINFORCEMENT (TYP)
SECOND STAGE
CONCRETE PLACEMENT
CONSTRUCTION OR
CONTRACTION JOINT
SEALED ISOLATION
JOINT DISCTONTINUE
REINFORCEMENT (TYP)
4" M
IN
INTERIOR
EXTERIOR
A
A
A
A
AT CONTRACTOR'S
OPTION, REPLACE
DIAMOND ISOLATION
JOINT WITH CIRCLE
0 "
4" M
IN
AT CONTRACTOR'S
OPTION, REPLACE
DIAMOND ISOLATION
JOINT WITH CIRCLE
0 "
NOTE:
USE CIRCULAR OPTION WHERE
NO FLOOR JOINTS INTERSECT.
NOTE:
FOR EXTERIOR ISOLATION JOINTS AT BRACED BAYS,
SECOND STAGE CONCRETE PLACEMENT SHALL
ENCASE ALL GUSSET PLATES AND BRACING MEMBERS.
COLUMN ISOLATION JOINTS
NOT TO SCALE
CONSTRUCTION OR
CONTRACTION JOINT
SEALED ISOLATION
JOINT DISCONTINUE
REINFORCEMENT (TYP)
SECOND STAGE
CONCRETE PLACEMENT
INSIDE CORNER
A
A
AT CONTRACTOR'S
OPTION, REPLACE
DIAMOND ISOLATION
JOINT WITH CIRCLE
0 "
4" M
IN
CONSTRUCTION OR
CONTRACTION JOINT
SEALED ISOLATION
JOINT DISCONTINUE
REINFORCEMENT (TYP)
SECOND STAGE
CONCRETE PLACEMENT
OUTSIDE CORNER
A
A
AT CONTRACTOR'S
OPTION, REPLACE
DIAMOND ISOLATION
JOINT WITH CIRCLE
0 "
4" M
IN
- 0
1' - 0"
FINISHED GRADE OR
PAVEMENT W/ EXP JT
SEE CIVIL DWGS
EQUIP ANCHORAGE
PER MFR
#4 @ 12"
EW T&B
(3) #4 EF
#4 @ 12"
PER EQPT MFR
NOTE: TYP 4 SIDES. COORD SIZE
WITH MANUFACTURER.
6" CAPILLARY
WATER BARRIER
NOT TO SCALE
EXTERIOR EQUIPMENT PAD (EP-2)
S c a le
F o r
M ic ro fi lm in g
In c h e s
M ill im e te rs date detailed checkeddesigned project contract rev.drawing file
no. date descriptionby ckd
J
H
G
F
E
D
C
B
A
C O
P Y
R
IG
H T
B
U R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
W9133L-15-D-0003-9M03
180TH FIGHTER WING
OHIO AIR NATIONAL GUARD
TOLEDO EXPRESS AIRPORT
SWANTON, OHIO
180th Fighter Wing Toledo Express Airport, OH
9400 WARD PARKWAY
KANSAS CITY, MO 64114
(816) 333-9400
REVISIONS
WYTD079031
K
Construct ACA Shelters
1 1098765432
/2 /2
:1
:3
P M
102134_S_CENTRAL
S-005
STANDARD CONCRETE DETAILS
19 MAR 2018
K. SMITH J. SCHMIDT
J. DELGADO
DETAIL
S-005