Draw_A-601_door_schedule.pdf
PDF 277 KB Posted
- Attached to
- Aircraft Alert Shelters Federal contract opportunity
- Solicitation number
- W9136419B8001
About this file
Drawing A-601
View the file
Other files for this federal contract opportunity
Show all 41
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NL
A
SCHEDULE
DOOR PER A
B
S C
H E
D U
L E
D O
O R
P E
R
D O
O R
P E
R S
C H
E D
U L E
SCHEDULE
DOOR PER
D O
O R
P E
R S
C H
E D
U L E
A D
B C
SCHEDULE
DOOR PER
OH
D O
O R
P E
R S
C H
E D
U L E
DOOR PER SCHEDULE
F
GENERAL NOTES -
DOOR & DOOR FRAME:
1.
2.
3.
4.
# ON DOOR ELEVATION REPRESENTS GLASS PANEL ON DOOR.
ALL HM DOORS AND DOOR FRAMES ARE GALVANIZED.
FABRIC HANGAR DOOR, SEE SPECIFICATION SECTION 08370.
FOR DOOR NUMBERS ON FLOOR PLAN, REFERENCE DRAWINGS A-101 & A-102.
GLASS INFILL TYPES:
REFERENCE SPECIFICATION FOR GLASS TYPES
1 FIRE / SAFETY GLASS (90 MINUTES)
2 FIRE / SAFETY GLASS (60 MINUTES)
NOTE: GLAZING RATING TO MATCH DOOR IT IS IN.
S c a le
F o r
M ic ro fi lm in g
In c h e s
M ill im e te rs date detailed checkeddesigned project contract rev.drawing file
no. date descriptionby ckd
J
H
G
F
E
D
C
B
A
C O
P Y
R
IG
H T
B
U R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
W9133L-15-D-0003-9M03
180TH FIGHTER WING
OHIO AIR NATIONAL GUARD
TOLEDO EXPRESS AIRPORT
SWANTON, OHIO
180th Fighter Wing Toledo Express Airport, OH
9400 WARD PARKWAY
KANSAS CITY, MO 64114
(816) 333-9400
REVISIONS
WYTD079031
K
Construct ACA Shelters
1 1098765432
/7 /2
:4
:1
A
M
102134_A_CENTRAL
A-601
DOOR SCHEDULES AND TYPES
30 JULY 2018
J. TOP Checker
C. SPRINKLE
DOOR SCHEDULE
DOOR
NUMBER
DOOR FRAME ASSEMBLY
RATING
(MINUTES)
DETAIL
HARDWARE
SET REMARKS
SIZE
TYPE MATERIAL TYPE MATERIAL HEAD JAMB SILLPAIR DOOR WIDTH HEIGHT
101C - 7' - 0" F-IN HM 1.1 HM - G1 / A-621 D1 / A-621 A1 / A-621 1
101D PR. 7' - 0" F-IN HM 1.1 HM - G1 / A-621 D1 / A-621 A1 / A-621 1
102C - 7' - 0" NL HM 1.1 HM 90 G4 / A-621 D4 / A-621 A4 / A-621 1
102D PR. DBL-EGRESS 3' - 0" 7' - 0" NL HM 1.1 HM 90 G4 / A-621 D4 / A-621 A4 / A-621 1
102E - 7' - 0" NL HM 1.1 HM 30 G4 / A-621 D4 / A-621 A4 / A-621 1
102F - 7' - 0" F-IN HM 1.1 HM - G1 / A-621 D1 / A-621 A1 / A-621 1
103C - 7' - 0" NL HM 1.1 HM 90 G1 / A-621 D4 / A-621 A4 / A-621 1
103D PR. DBL-EGRESS 3' - 0" 7' - 0" NL HM 1.1 HM 90 G4 / A-621 D4 / A-621 A4 / A-621 1
103E - 7' - 0" NL HM 1.1 HM 30 G4 / A-621 D4 / A-621 A4 / A-621 1
103F - 7' - 0" F-IN HM 1.1 HM - G1 / A-621 D1 / A-621 A1 / A-621 1
104C - 7' - 0" F-IN HM 1.1 HM - G1 / A-621 D1 / A-621 A1 / A-621 1
104D PR. 7' - 0" F-IN HM 1.1 HM - G1 / A-621 D1 / A-621 A1 / A-621 1
105A PR. 3' - 0" 7' - 0" F-IN HM 1.1 HM - G1 / A-621 D1 / A-621 A1 / A-621 3
106A - 7' - 0" NL HM 1.1 HM 30 G4 / A-621 D4 / A-621 A4 / A-621 2
107A PR. 7' - 0" NL HM 1.1 HM 30 G4 / A-621 D4 / A-621 A4 / A-621 3
108A PR. 7' - 0" F-IN HM 1.1 HM - G1 / A-621 D1 / A-621 A1 / A-621 3
DOOR AND FRAME LEGEND
FINISH
FF-1* FACTORY FINISHED
PE-1** PAINT-EPOXY
MATERIAL
AL ALUMINUM
HM HOLLOW METAL
WD WOOD
SIZE
- SINGLE DOOR
PR PAIR OF DOORS
UPR UNEQUAL PAIR
*REFERENCE DOOR OR FRAME SPECIFICATION
**FIELD APPLY PER PAINT SPECIFICATION FOR
APPLICABLE SUBSTRATE AND EXPOSURE.
SCALE: 1/4" = 1'-0"
DOOR & FRAME TYPES
(FLUSH PANEL)
TYPE DESCRIPTION
F-IN FLUSH PANEL INSULATED
(NARROW LIGHT)
TYPE DESCRIPTION A B C D #
NL NARROW LITE 6" 48" 24" 4" 1
(OVERHEAD)
TYPE DESCRIPTION
(DOOR FRAME)
TYPE A B
1.1 2" 2"
1 11/07/18 JST JLC AMENDMENT 0001
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
4' - 0"
| Sheets |
| A-601 - DOOR SCHEDULES AND TYPES |
| 2018-11-07T14:50:41-0500 | |
| Cole, Lee |
File details come from the government source that posted it.