NLZG102008_RenovateHangar885_Full_Drawing_Set_Vol_02-IFB_Part_3_of_3.pdf
PDF 7 MB Posted
- Attached to
- Renovate Hangar 885
- Solicitation number
- W9136418B5000
About this file
W9136418B5000 - Drawings Volume 2 (file 3 of 3)
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2RL
3RL2RL
US
US
2RL
2RL
OS
OS
2RL
OS
OS
OSOS
OS
OS
2RL
OS
OS
2RL
D
E
F
G
H
345 1B 1A
Secure Room
Men's
Women's
Supply
IT
AMU Open Office
Maintenance Hangar
Corridor
C15Stair
S3
Debrief
Corridor
C16
Entry
Elevator
E1
LA
LA
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
DK
FAFA FAFAFA
FA
FA
DG
DG
DG
LA LA LA LA
CA
LA LA
FA
LA
GA
Janitor
164 CA
CA
FA
Flight Chiefs
Entry
FA
XA
DK DK DK
DKDKDK
XA
XA
FA
FA
FA
EM2- 1
EM2- 1
EM2- 1LI-103- 1
EM2- 1
LI-103- 1 LI-103- 1 LI-103- 1
EM2- 1
LI-103- 1
LI-103- 1LI-103- 1LI-103- 1LI-103- 1
LI-103- 1 LI-103- 1 LI-103- 1 LI-103- 1 EM2- 1
LI-103- 1 LI-103- 1 LI-103- 1 LI-103- 1 LI-103- 1 LI-103- 1 LI-103- 1
EM2- 1
LI-103- 1 LI-103- 1 LI-103- 1
LI-103- 1
EM2- 1
LI-103- 1
LI-103- 1LI-103- 1LI-103- 1LI-103- 1LI-103- 1EM2- 1
EM2- 1 LI-103- 2 LI-103- 2
EM2- 1
LI-103- 2
LI-103- 2
LI-103- 2LI-103- 2
LI-103- 2
LI-103- 2
EM2- 1
LI-103- 2
LI-103- 2LI-103- 2
LI-103- 2
LI-103- 2 LI-103- 2
LI-103- 2 LI-103- 2
EM2- 1LI-103- 2
LI-103- 2
LI-103- 1
CSCS
CS
P2 P1
XA
XA
FA
EM2- 1
PP
PP
NL NL
NL
NL
NL
NL
NL
NL
NL
CA
LI-103- 1
EM2- 1
EM2- 1
DK DK DK
LI-103- 1 LI-103- 1 LI-103- 1
EM2- 1
EM2- 1
HA
HA
WC
EM2- 1
WC
EM2- 1
EM2- 1P2
P2
P2
P2 P2
S1
S1 P2
DSP2
P1
P2 P1
P2
P2
NL
GA
EM2- 1
DK
DK
DK
LI-103- 1
LI-103- 1
LI-103- 1
DK
LI-103- 1
CA
EM2- 1
CA
LI-103- 2
EM2- 1
MATCHLINE
MATCHLINE
GENERAL NOTES:
A. COORDINATE LOCATION OF LIGHT FIXTURES WITH STRUCTURE AND
MECHANICAL EQUIPMENT AND DUCT WORK TO AVOID CONFLICTS.
B. ALL INDIVIDUAL BATTERY POWERED LIGHTING AND EXIT SIGNS SHALL BE
CONNECTED TO THE SAME BRANCH CIRCUIT SERVING THE NORMAL LIGHTS
AND SHALL BE ON THE LINE SIDE OF RELAYS OR SWITCHING DEVICES.
C. REFER TO KEYED NOTES FOR CONTROL OF ADDITIONAL EMERGENCY LIGHTING.
ALL EXIT SIGNS SHALL BE CONNECTED FOR CONTINUOUS OPERATION.
D. INDUSTRIAL LIGHTING FIXTURES SHOWN IN MECHANICAL ROOMS, ELECTRICAL
ROOMS, TELECOMMUNICATIONS ROOMS, STORAGE AREAS, JANITOR CLOSETS,
AND SHOPS SHALL BE COORDINATED WITH EQUIPMENT PRIOR TO
INSTALLATION TO AVOID ANY CONFLICTS AND PROVIDE MAXIMUM LIGHTING IN
WORKING SPACES.
E. OCCUPANCY SENSORS IN CORRIDORS SHALL CONTROL ALL FIXTURES
INDICATED AND DIM TO 50% WHEN NO OCCUPANCY IS SENSED FOR 30
MINUTES. ALL OTHER OCCUPANCY SENSORS THROUGHOUT THE FACILITY
SHALL TURN ON FIXTURES TO 50% OF FULL LIGHT OUTPUT. OCCUPANT CAN
MANUALLY DIM OR SWITCH THE LIGHTS TO A HIGHER PERCENTAGE OF FULL
LIGHT OUTPUT. UPON SENSING VACANCY FOR 15 MINUTES, THE LIGHTS TURN
OFF.
F. AT LOCATIONS WHERE ROOM LIGHT FIXTURES ARE CONTROLLED THROUGH
THE USE OF OCCUPANCY SENSORS, PROVIDE THE NUMBER OF SENSORS AND
LOCATE THE UNITS AS REQUIRED FOR COMPLETE ROOM COVERAGE. WHERE
MORE THAN ONE SENSOR IS LOCATED IN A COMMON SPACE, CONNECT THE
UNITS SUCH THAT DETECTION OF OCCUPANCY FROM EITHER UNIT WILL
ENERGIZE ALL OF THE LIGHTING. WHERE SWITCHES ARE SHOWN IN
CONJUNCTION WITH OCCUPANCY SENSORS, CONNECT THE SWITCHES TO DE-
ENERGIZE THE LIGHTING INDICATED REGARDLESS OF OCCUPANCY. ADJUST
ALL SENSOR TIME DELAYS AND MOTION SENSITIVITIES DURING PROJECT
CLOSEOUT TO MEET THE OPERATIONAL FUNCTION OF THE OWNER.
G. RECESSED DOWN LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE
PROVIDED WITH ADJUSTABLE T-BAR ATTACHMENT ARMS MANUFACTURED BY
THE LIGHT FIXTURE COMPANY.
H. REFER TO SHEET E-601 FOR LIGHTING FIXTURE SCHEDULE.
I. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
N
E
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:2
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
FIRST FLOOR ELECTRICAL
LIGHTING PLAN - AREA E
EL101-E
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EL101-E
FIRST FLOOR ELECTRICAL
LIGHTING PLAN - AREA E
CODED NOTES
1 THIS LIGHT SHALL BE PROVIDED WITH AN
ADDITIONAL UL925 LISTED TRANSFER DEVICE EQUAL
TO A BODINE GTB, THIS DEVICE SHALL ACCEPT BOTH
THE NORMAL LIGHTING CIRCUIT (WITHIN THIS ROOM)
AND ALSO THE DESIGNATED CIRCUIT FROM THE
INVERTER PANEL.
2 REPLACE EXISTING PARKING LOT LIGHTS. EXTEND
2#10+1#10 GND IN 3/4" CONDUIT TO PANEL VIA NEW
LIGHTING CONTROLS.
I/R DATE DESCRIPTION
A
B
C
D
345 1B 1A
C.4
WFWF
LE-101- 3LE-101- 3
WC
EM2- 1
GA EM2- 1
MATCHLINE
M A
T C
H L
IN
E
GENERAL NOTES:
A. COORDINATE LOCATION OF LIGHT FIXTURES WITH STRUCTURE AND
MECHANICAL EQUIPMENT AND DUCT WORK TO AVOID CONFLICTS.
B. ALL INDIVIDUAL BATTERY POWERED LIGHTING AND EXIT SIGNS SHALL BE
CONNECTED TO THE SAME BRANCH CIRCUIT SERVING THE NORMAL LIGHTS
AND SHALL BE ON THE LINE SIDE OF RELAYS OR SWITCHING DEVICES.
C. REFER TO KEYED NOTES FOR CONTROL OF ADDITIONAL EMERGENCY LIGHTING.
ALL EXIT SIGNS SHALL BE CONNECTED FOR CONTINUOUS OPERATION.
D. INDUSTRIAL LIGHTING FIXTURES SHOWN IN MECHANICAL ROOMS, ELECTRICAL
ROOMS, TELECOMMUNICATIONS ROOMS, STORAGE AREAS, JANITOR CLOSETS,
AND SHOPS SHALL BE COORDINATED WITH EQUIPMENT PRIOR TO
INSTALLATION TO AVOID ANY CONFLICTS AND PROVIDE MAXIMUM LIGHTING IN
WORKING SPACES.
E. OCCUPANCY SENSORS IN CORRIDORS SHALL CONTROL ALL FIXTURES
INDICATED AND DIM TO 50% WHEN NO OCCUPANCY IS SENSED FOR 30
MINUTES. ALL OTHER OCCUPANCY SENSORS THROUGHOUT THE FACILITY
SHALL TURN ON FIXTURES TO 50% OF FULL LIGHT OUTPUT. OCCUPANT CAN
MANUALLY DIM OR SWITCH THE LIGHTS TO A HIGHER PERCENTAGE OF FULL
LIGHT OUTPUT. UPON SENSING VACANCY FOR 15 MINUTES, THE LIGHTS TURN
OFF.
F. AT LOCATIONS WHERE ROOM LIGHT FIXTURES ARE CONTROLLED THROUGH
THE USE OF OCCUPANCY SENSORS, PROVIDE THE NUMBER OF SENSORS AND
LOCATE THE UNITS AS REQUIRED FOR COMPLETE ROOM COVERAGE. WHERE
MORE THAN ONE SENSOR IS LOCATED IN A COMMON SPACE, CONNECT THE
UNITS SUCH THAT DETECTION OF OCCUPANCY FROM EITHER UNIT WILL
ENERGIZE ALL OF THE LIGHTING. WHERE SWITCHES ARE SHOWN IN
CONJUNCTION WITH OCCUPANCY SENSORS, CONNECT THE SWITCHES TO DE-
ENERGIZE THE LIGHTING INDICATED REGARDLESS OF OCCUPANCY. ADJUST
ALL SENSOR TIME DELAYS AND MOTION SENSITIVITIES DURING PROJECT
CLOSEOUT TO MEET THE OPERATIONAL FUNCTION OF THE OWNER.
G. RECESSED DOWN LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE
PROVIDED WITH ADJUSTABLE T-BAR ATTACHMENT ARMS MANUFACTURED BY
THE LIGHT FIXTURE COMPANY.
H. REFER TO SHEET E-601 FOR LIGHTING FIXTURE SCHEDULE.
I. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
N
F
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:2
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
FIRST FLOOR ELECTRICAL
LIGHTING PLAN - AREA F
EL101-F
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EL101-F
FIRST FLOOR ELECTRICAL
LIGHTING PLAN - AREA F
CODED NOTES
1 REPLACE EXISTING PARKING LOT LIGHTS. EXTEND 2#10+1#10 GND IN
3/4" CONDUIT TO PANEL VIA NEW LIGHTING CONTROLS.
2 WALL MOUNTED LIGHTING FIXTURE AND ASSOCIATED SWITCH FOR
HANGER POCKET DOOR LIGHTING. COORDINATE EXACT LOCATION AND
MOUNTING HEIGHT WITH CONTRACTING OFFICER REPRESENTATIVE.
3 THIS LIGHT SHALL BE PROVIDED WITH AN ADDITIONAL UL925 LISTED
TRANSFER DEVICE EQUAL TO A BODINE GTB, THIS DEVICE SHALL
ACCEPT BOTH THE NORMAL LIGHTING CIRCUIT (WITHIN THIS ROOM)
AND ALSO THE DESIGNATED CIRCUIT FROM THE INVERTER PANEL.
H
J
K
L
M
56789101C1D 9.2 8.3 7.3 6.9
DC
LADDER ACCESS LADDER ACCESS
DC DC
DC DC DC
XA
EM1- 6
LI-101- 2LI-101- 2 EM1- 6
LI-101- 2 EM1- 6 LI-101- 2
3,P
M A
T C
H L
IN
E
MATCHLINE
GENERAL NOTES:
A. COORDINATE LOCATION OF LIGHT FIXTURES WITH STRUCTURE AND
MECHANICAL EQUIPMENT AND DUCT WORK TO AVOID CONFLICTS.
B. ALL INDIVIDUAL BATTERY POWERED LIGHTING AND EXIT SIGNS SHALL BE
CONNECTED TO THE SAME BRANCH CIRCUIT SERVING THE NORMAL LIGHTS
AND SHALL BE ON THE LINE SIDE OF RELAYS OR SWITCHING DEVICES.
C. REFER TO KEYED NOTES FOR CONTROL OF ADDITIONAL EMERGENCY LIGHTING.
ALL EXIT SIGNS SHALL BE CONNECTED FOR CONTINUOUS OPERATION.
D. INDUSTRIAL LIGHTING FIXTURES SHOWN IN MECHANICAL ROOMS, ELECTRICAL
ROOMS, TELECOMMUNICATIONS ROOMS, STORAGE AREAS, JANITOR CLOSETS,
AND SHOPS SHALL BE COORDINATED WITH EQUIPMENT PRIOR TO
INSTALLATION TO AVOID ANY CONFLICTS AND PROVIDE MAXIMUM LIGHTING IN
WORKING SPACES.
E. OCCUPANCY SENSORS IN CORRIDORS SHALL CONTROL ALL FIXTURES
INDICATED AND DIM TO 50% WHEN NO OCCUPANCY IS SENSED FOR 30
MINUTES. ALL OTHER OCCUPANCY SENSORS THROUGHOUT THE FACILITY
SHALL TURN ON FIXTURES TO 50% OF FULL LIGHT OUTPUT. OCCUPANT CAN
MANUALLY DIM OR SWITCH THE LIGHTS TO A HIGHER PERCENTAGE OF FULL
LIGHT OUTPUT. UPON SENSING VACANCY FOR 15 MINUTES, THE LIGHTS TURN
OFF.
F. AT LOCATIONS WHERE ROOM LIGHT FIXTURES ARE CONTROLLED THROUGH
THE USE OF OCCUPANCY SENSORS, PROVIDE THE NUMBER OF SENSORS AND
LOCATE THE UNITS AS REQUIRED FOR COMPLETE ROOM COVERAGE. WHERE
MORE THAN ONE SENSOR IS LOCATED IN A COMMON SPACE, CONNECT THE
UNITS SUCH THAT DETECTION OF OCCUPANCY FROM EITHER UNIT WILL
ENERGIZE ALL OF THE LIGHTING. WHERE SWITCHES ARE SHOWN IN
CONJUNCTION WITH OCCUPANCY SENSORS, CONNECT THE SWITCHES TO DE-
ENERGIZE THE LIGHTING INDICATED REGARDLESS OF OCCUPANCY. ADJUST
ALL SENSOR TIME DELAYS AND MOTION SENSITIVITIES DURING PROJECT
CLOSEOUT TO MEET THE OPERATIONAL FUNCTION OF THE OWNER.
G. RECESSED DOWN LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE
PROVIDED WITH ADJUSTABLE T-BAR ATTACHMENT ARMS MANUFACTURED BY
THE LIGHT FIXTURE COMPANY.
H. REFER TO SHEET E-601 FOR LIGHTING FIXTURE SCHEDULE.
I. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
N A
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:3
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
SECOND FLOOR ELECTRICAL
LIGHTING PLAN - AREA A
EL102-A
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EL102-A
SECOND FLOOR ELECTRICAL
LIGHTING PLAN - AREA A
CODED NOTES
1 THIS LIGHT SHALL BE PROVIDED WITH AN
ADDITIONAL UL925 LISTED TRANSFER DEVICE EQUAL
TO A BODINE GTB, THIS DEVICE SHALL ACCEPT BOTH
THE NORMAL LIGHTING CIRCUIT (WITHIN THIS ROOM)
AND ALSO THE DESIGNATED CIRCUIT FROM THE
INVERTER PANEL.
OS
OS
D
E
F
G
H
56789101C1D 9.2 8.3 7.3 6.9
Electrical Closet
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
LADDER ACCESS
Stair
S1
XA
EM1- 6
LI-102- 5 LI-102- 5 EM1- 6 LI-102- 5 LI-102- 5
LI-102- 5 LI-102- 5
EM1- 6
LI-102- 5
LI-102- 5
EM1- 6
LI-102- 5
LI-102- 5
LI-102- 5LI-102- 5
LI-102- 5LI-102- 5
EM1- 6
LI-102- 5
LI-102- 5
LI-102- 5
LI-102- 5
EM1- 6XB
3,P
3,P
3,P 3,P
MATCHLINE
MATCHLINE
GENERAL NOTES:
A. COORDINATE LOCATION OF LIGHT FIXTURES WITH STRUCTURE AND
MECHANICAL EQUIPMENT AND DUCT WORK TO AVOID CONFLICTS.
B. ALL INDIVIDUAL BATTERY POWERED LIGHTING AND EXIT SIGNS SHALL BE
CONNECTED TO THE SAME BRANCH CIRCUIT SERVING THE NORMAL LIGHTS
AND SHALL BE ON THE LINE SIDE OF RELAYS OR SWITCHING DEVICES.
C. REFER TO KEYED NOTES FOR CONTROL OF ADDITIONAL EMERGENCY LIGHTING.
ALL EXIT SIGNS SHALL BE CONNECTED FOR CONTINUOUS OPERATION.
D. INDUSTRIAL LIGHTING FIXTURES SHOWN IN MECHANICAL ROOMS, ELECTRICAL
ROOMS, TELECOMMUNICATIONS ROOMS, STORAGE AREAS, JANITOR CLOSETS,
AND SHOPS SHALL BE COORDINATED WITH EQUIPMENT PRIOR TO
INSTALLATION TO AVOID ANY CONFLICTS AND PROVIDE MAXIMUM LIGHTING IN
WORKING SPACES.
E. OCCUPANCY SENSORS IN CORRIDORS SHALL CONTROL ALL FIXTURES
INDICATED AND DIM TO 50% WHEN NO OCCUPANCY IS SENSED FOR 30
MINUTES. ALL OTHER OCCUPANCY SENSORS THROUGHOUT THE FACILITY
SHALL TURN ON FIXTURES TO 50% OF FULL LIGHT OUTPUT. OCCUPANT CAN
MANUALLY DIM OR SWITCH THE LIGHTS TO A HIGHER PERCENTAGE OF FULL
LIGHT OUTPUT. UPON SENSING VACANCY FOR 15 MINUTES, THE LIGHTS TURN
OFF.
F. AT LOCATIONS WHERE ROOM LIGHT FIXTURES ARE CONTROLLED THROUGH
THE USE OF OCCUPANCY SENSORS, PROVIDE THE NUMBER OF SENSORS AND
LOCATE THE UNITS AS REQUIRED FOR COMPLETE ROOM COVERAGE. WHERE
MORE THAN ONE SENSOR IS LOCATED IN A COMMON SPACE, CONNECT THE
UNITS SUCH THAT DETECTION OF OCCUPANCY FROM EITHER UNIT WILL
ENERGIZE ALL OF THE LIGHTING. WHERE SWITCHES ARE SHOWN IN
CONJUNCTION WITH OCCUPANCY SENSORS, CONNECT THE SWITCHES TO DE-
ENERGIZE THE LIGHTING INDICATED REGARDLESS OF OCCUPANCY. ADJUST
ALL SENSOR TIME DELAYS AND MOTION SENSITIVITIES DURING PROJECT
CLOSEOUT TO MEET THE OPERATIONAL FUNCTION OF THE OWNER.
G. RECESSED DOWN LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE
PROVIDED WITH ADJUSTABLE T-BAR ATTACHMENT ARMS MANUFACTURED BY
THE LIGHT FIXTURE COMPANY.
H. REFER TO SHEET E-601 FOR LIGHTING FIXTURE SCHEDULE.
I. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
N
B
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:3
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
SECOND FLOOR ELECTRICAL
LIGHTING PLAN - AREA B
EL102-B
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EL102-B
SECOND FLOOR ELECTRICAL
LIGHTING PLAN - AREA B
CODED NOTES
1 THIS LIGHT SHALL BE PROVIDED WITH AN
ADDITIONAL UL925 LISTED TRANSFER DEVICE EQUAL
TO A BODINE GTB, THIS DEVICE SHALL ACCEPT BOTH
THE NORMAL LIGHTING CIRCUIT (WITHIN THIS ROOM)
AND ALSO THE DESIGNATED CIRCUIT FROM THE
3RL
3RL
3RL
3RL
3RL
3RL
3RL
3RL
3RL
OS
3RL
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
H
J
K
L
M
345 1B 1A
Supply
Consult
CRF Chief
EMF Chief
AMXS Chief
Stair
S2
First Sgt
First Sgt
MOF Chief
Corridor
C21
DE
DE
DD DD
DD DD
DD DD
DD DD
DD
DD
DE
GA
Conference / Standup Room
Maint. Officers
CA
DE DE
DE
DE
DE DE
DEDE
DE DE
DC
DC
DC
DC
DD DD
LI-103- 3
LI-103- 3
LI-103- 3
LI-103- 3 LI-103- 3
LI-103- 3LI-103- 3
LI-103- 3 LI-103- 3
LI-103- 3 LI-103- 3
LI-103- 3 LI-103- 3
LI-103- 3
EM2- 2
LI-103- 3LI-103- 3
LI-103- 3 LI-103- 3
LI-103- 3LI-103- 3
LI-103- 3LI-103- 3
LI-103- 3 LI-103- 3
LI-103- 3 LI-103- 3
LI-103- 3
LI-103- 3
LI-103- 3
EM2- 2
EM2- 2XA
NL
NL
NL
DD
LI-103- 3
DD
EM2- 2
DD
LI-103- 3
DD
LI-103- 3
DD
EM2- 2
P2
P1
P1
P2
P1P2
P1P2
P1P2
P1P2
P1P2
P1P2 P2
P2
S1
P2
S1
P2
P2
Storage
DE
LI-103- 3
DCDC
LI-103- 3 LI-103- 3
M A
T C
H L
IN
E
MATCHLINE
GENERAL NOTES:
A. COORDINATE LOCATION OF LIGHT FIXTURES WITH STRUCTURE AND
MECHANICAL EQUIPMENT AND DUCT WORK TO AVOID CONFLICTS.
B. ALL INDIVIDUAL BATTERY POWERED LIGHTING AND EXIT SIGNS SHALL BE
CONNECTED TO THE SAME BRANCH CIRCUIT SERVING THE NORMAL LIGHTS
AND SHALL BE ON THE LINE SIDE OF RELAYS OR SWITCHING DEVICES.
C. REFER TO KEYED NOTES FOR CONTROL OF ADDITIONAL EMERGENCY LIGHTING.
ALL EXIT SIGNS SHALL BE CONNECTED FOR CONTINUOUS OPERATION.
D. INDUSTRIAL LIGHTING FIXTURES SHOWN IN MECHANICAL ROOMS, ELECTRICAL
ROOMS, TELECOMMUNICATIONS ROOMS, STORAGE AREAS, JANITOR CLOSETS,
AND SHOPS SHALL BE COORDINATED WITH EQUIPMENT PRIOR TO
INSTALLATION TO AVOID ANY CONFLICTS AND PROVIDE MAXIMUM LIGHTING IN
WORKING SPACES.
E. OCCUPANCY SENSORS IN CORRIDORS SHALL CONTROL ALL FIXTURES
INDICATED AND DIM TO 50% WHEN NO OCCUPANCY IS SENSED FOR 30
MINUTES. ALL OTHER OCCUPANCY SENSORS THROUGHOUT THE FACILITY
SHALL TURN ON FIXTURES TO 50% OF FULL LIGHT OUTPUT. OCCUPANT CAN
MANUALLY DIM OR SWITCH THE LIGHTS TO A HIGHER PERCENTAGE OF FULL
LIGHT OUTPUT. UPON SENSING VACANCY FOR 15 MINUTES, THE LIGHTS TURN
OFF.
F. AT LOCATIONS WHERE ROOM LIGHT FIXTURES ARE CONTROLLED THROUGH
THE USE OF OCCUPANCY SENSORS, PROVIDE THE NUMBER OF SENSORS AND
LOCATE THE UNITS AS REQUIRED FOR COMPLETE ROOM COVERAGE. WHERE
MORE THAN ONE SENSOR IS LOCATED IN A COMMON SPACE, CONNECT THE
UNITS SUCH THAT DETECTION OF OCCUPANCY FROM EITHER UNIT WILL
ENERGIZE ALL OF THE LIGHTING. WHERE SWITCHES ARE SHOWN IN
CONJUNCTION WITH OCCUPANCY SENSORS, CONNECT THE SWITCHES TO DE-
ENERGIZE THE LIGHTING INDICATED REGARDLESS OF OCCUPANCY. ADJUST
ALL SENSOR TIME DELAYS AND MOTION SENSITIVITIES DURING PROJECT
CLOSEOUT TO MEET THE OPERATIONAL FUNCTION OF THE OWNER.
G. RECESSED DOWN LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE
PROVIDED WITH ADJUSTABLE T-BAR ATTACHMENT ARMS MANUFACTURED BY
THE LIGHT FIXTURE COMPANY.
H. REFER TO SHEET E-601 FOR LIGHTING FIXTURE SCHEDULE.
I. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
N D
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:4
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
SECOND FLOOR ELECTRICAL
LIGHTING PLAN - AREA D
EL102-D
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EL102-D
SECOND FLOOR ELECTRICAL
LIGHTING PLAN - AREA D
CODED NOTES
1 THIS LIGHT SHALL BE PROVIDED WITH AN ADDITIONAL UL925 LISTED
TRANSFER DEVICE EQUAL TO A BODINE GTB, THIS DEVICE SHALL
ACCEPT BOTH THE NORMAL LIGHTING CIRCUIT (WITHIN THIS ROOM)
US US
3R L
3RL
2RL
2RL
2RL
2RL
2RL
2RL
2RL
2RL
3RL
OS
OS
OS
OS
OS
3RL
OS
OS
2RL
OS
OS
D
E
F
G
H
345 1B 1A
Secure Briefing
MOC
QA
Plans & Sch.
Women
Counseling
Analysis
Men
Stair
S3
QA Office
MOC Secure
Elevator
E1
LA LA
AA
LA
LA
CA
AA
AA
LA
AA
LA
FA
FA
FA
FA
DJDJDJ
DJDJDJ
DJDJDJ
DJDJDJ
GA
LALA
Coffee Bar
LA
LI-102- 5
LI-103- 4
LI-103- 4
EM2- 2 LI-103- 4
EM2- 2
EM2- 2
EM2- 2
EM2- 2
EM2- 2
LI-103- 4
LI-103- 4
LI-103- 4
LI-103- 4
BPL-201- 19
BPL-201- 19BPL-201- 19
BPL-201- 19BPL-201- 19
BPL-201- 19
LI-103- 4
EM2- 2
LI-103- 4
EM2- 2
EM2- 2
EM2- 2
LI-103- 5
EM2- 2
BPL-201- 19 BPL-201- 19 BPL-201- 19
BPL-201- 19BPL-201- 19BPL-201- 19
XA
XA
XA
XA EM2- 2
EM2- 2
NL
NL
NL
NL
Corridor
C20
NL
CA
LI-103- 5
AA
AA
AA
AA
AA
AA
AAAA
AA
AA
AA
AA
AD AD
AD AD
AD AD
AD AD
LI-103- 4LI-103- 4
LI-103- 4
LI-103- 4
BPL-201- 21 BPL-201- 21
BPL-201- 21BPL-201- 21
BPL-201- 21BPL-201- 21LI-103- 4
LI-103- 4
LI-103- 4
LI-103- 4
LI-103- 4
LI-103- 4 LI-103- 4
LI-103- 4
P1P2 P2
S1P2
S1
S1
P2
P2 P2
S2
DS
P1
P2
S2
P1
P1
S2
S2
DS
P1
P2
P2
P1
P2
P1
P2
P2
Storage
DJ
BPL-201- 19
DJ
BPL-201- 19
DJ
BPL-201- 19
DJ
BPL-201- 19
DJ
BPL-201- 19
DJ
BPL-201- 19
LI-103- 4
LI-103- 4
FA
FA
BPL-201- 21
BPL-201- 21
1 1
EM2- 2
FC
MATCHLINE
MATCHLINE
GENERAL NOTES:
A. COORDINATE LOCATION OF LIGHT FIXTURES WITH STRUCTURE AND
MECHANICAL EQUIPMENT AND DUCT WORK TO AVOID CONFLICTS.
B. ALL INDIVIDUAL BATTERY POWERED LIGHTING AND EXIT SIGNS SHALL BE
CONNECTED TO THE SAME BRANCH CIRCUIT SERVING THE NORMAL LIGHTS
AND SHALL BE ON THE LINE SIDE OF RELAYS OR SWITCHING DEVICES.
C. REFER TO KEYED NOTES FOR CONTROL OF ADDITIONAL EMERGENCY LIGHTING.
ALL EXIT SIGNS SHALL BE CONNECTED FOR CONTINUOUS OPERATION.
D. INDUSTRIAL LIGHTING FIXTURES SHOWN IN MECHANICAL ROOMS, ELECTRICAL
ROOMS, TELECOMMUNICATIONS ROOMS, STORAGE AREAS, JANITOR CLOSETS,
AND SHOPS SHALL BE COORDINATED WITH EQUIPMENT PRIOR TO
INSTALLATION TO AVOID ANY CONFLICTS AND PROVIDE MAXIMUM LIGHTING IN
WORKING SPACES.
E. OCCUPANCY SENSORS IN CORRIDORS SHALL CONTROL ALL FIXTURES
INDICATED AND DIM TO 50% WHEN NO OCCUPANCY IS SENSED FOR 30
MINUTES. ALL OTHER OCCUPANCY SENSORS THROUGHOUT THE FACILITY
SHALL TURN ON FIXTURES TO 50% OF FULL LIGHT OUTPUT. OCCUPANT CAN
MANUALLY DIM OR SWITCH THE LIGHTS TO A HIGHER PERCENTAGE OF FULL
LIGHT OUTPUT. UPON SENSING VACANCY FOR 15 MINUTES, THE LIGHTS TURN
OFF.
F. AT LOCATIONS WHERE ROOM LIGHT FIXTURES ARE CONTROLLED THROUGH
THE USE OF OCCUPANCY SENSORS, PROVIDE THE NUMBER OF SENSORS AND
LOCATE THE UNITS AS REQUIRED FOR COMPLETE ROOM COVERAGE. WHERE
MORE THAN ONE SENSOR IS LOCATED IN A COMMON SPACE, CONNECT THE
UNITS SUCH THAT DETECTION OF OCCUPANCY FROM EITHER UNIT WILL
ENERGIZE ALL OF THE LIGHTING. WHERE SWITCHES ARE SHOWN IN
CONJUNCTION WITH OCCUPANCY SENSORS, CONNECT THE SWITCHES TO DE-
ENERGIZE THE LIGHTING INDICATED REGARDLESS OF OCCUPANCY. ADJUST
ALL SENSOR TIME DELAYS AND MOTION SENSITIVITIES DURING PROJECT
CLOSEOUT TO MEET THE OPERATIONAL FUNCTION OF THE OWNER.
G. RECESSED DOWN LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE
PROVIDED WITH ADJUSTABLE T-BAR ATTACHMENT ARMS MANUFACTURED BY
THE LIGHT FIXTURE COMPANY.
H. REFER TO SHEET E-601 FOR LIGHTING FIXTURE SCHEDULE.
I. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
N
E
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:4
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
SECOND FLOOR ELECTRICAL
LIGHTING PLAN - AREA E
EL102-E
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EL102-E
SECOND FLOOR ELECTRICAL
LIGHTING PLAN - AREA E
CODED NOTES
1 THIS LIGHT SHALL BE PROVIDED WITH AN ADDITIONAL UL925 LISTED
TRANSFER DEVICE EQUAL TO A BODINE GTB, THIS DEVICE SHALL
ACCEPT BOTH THE NORMAL LIGHTING CIRCUIT (WITHIN THIS ROOM)
D
E
F
G
H
56789101C1D 9.2 8.3 7.3 6.9
DC
DC DC
DC DC
DC
LADDER ACCESS
LI-103- 6 LI-103- 6 LI-103- 6
LI-103- 6 EM1- 6 LI-103- 6
EM1- 6
XA
3,P
MATCHLINE
MATCHLINE
GENERAL NOTES:
A. COORDINATE LOCATION OF LIGHT FIXTURES WITH STRUCTURE AND
MECHANICAL EQUIPMENT AND DUCT WORK TO AVOID CONFLICTS.
B. ALL INDIVIDUAL BATTERY POWERED LIGHTING AND EXIT SIGNS SHALL BE
CONNECTED TO THE SAME BRANCH CIRCUIT SERVING THE NORMAL LIGHTS
AND SHALL BE ON THE LINE SIDE OF RELAYS OR SWITCHING DEVICES.
C. REFER TO KEYED NOTES FOR CONTROL OF ADDITIONAL EMERGENCY LIGHTING.
ALL EXIT SIGNS SHALL BE CONNECTED FOR CONTINUOUS OPERATION.
D. INDUSTRIAL LIGHTING FIXTURES SHOWN IN MECHANICAL ROOMS, ELECTRICAL
ROOMS, TELECOMMUNICATIONS ROOMS, STORAGE AREAS, JANITOR CLOSETS,
AND SHOPS SHALL BE COORDINATED WITH EQUIPMENT PRIOR TO
INSTALLATION TO AVOID ANY CONFLICTS AND PROVIDE MAXIMUM LIGHTING IN
WORKING SPACES.
E. OCCUPANCY SENSORS IN CORRIDORS SHALL CONTROL ALL FIXTURES
INDICATED AND DIM TO 50% WHEN NO OCCUPANCY IS SENSED FOR 30
MINUTES. ALL OTHER OCCUPANCY SENSORS THROUGHOUT THE FACILITY
SHALL TURN ON FIXTURES TO 50% OF FULL LIGHT OUTPUT. OCCUPANT CAN
MANUALLY DIM OR SWITCH THE LIGHTS TO A HIGHER PERCENTAGE OF FULL
LIGHT OUTPUT. UPON SENSING VACANCY FOR 15 MINUTES, THE LIGHTS TURN
OFF.
F. AT LOCATIONS WHERE ROOM LIGHT FIXTURES ARE CONTROLLED THROUGH
THE USE OF OCCUPANCY SENSORS, PROVIDE THE NUMBER OF SENSORS AND
LOCATE THE UNITS AS REQUIRED FOR COMPLETE ROOM COVERAGE. WHERE
MORE THAN ONE SENSOR IS LOCATED IN A COMMON SPACE, CONNECT THE
UNITS SUCH THAT DETECTION OF OCCUPANCY FROM EITHER UNIT WILL
ENERGIZE ALL OF THE LIGHTING. WHERE SWITCHES ARE SHOWN IN
CONJUNCTION WITH OCCUPANCY SENSORS, CONNECT THE SWITCHES TO DE-
ENERGIZE THE LIGHTING INDICATED REGARDLESS OF OCCUPANCY. ADJUST
ALL SENSOR TIME DELAYS AND MOTION SENSITIVITIES DURING PROJECT
CLOSEOUT TO MEET THE OPERATIONAL FUNCTION OF THE OWNER.
G. RECESSED DOWN LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE
PROVIDED WITH ADJUSTABLE T-BAR ATTACHMENT ARMS MANUFACTURED BY
THE LIGHT FIXTURE COMPANY.
H. REFER TO SHEET E-601 FOR LIGHTING FIXTURE SCHEDULE.
I. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
N
B
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:5
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
THIRD FLOOR ELECTRICAL
LIGHTING PLAN - AREA B
EL103-B
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EL103-B
THIRD FLOOR ELECTRICAL
LIGHTING PLAN - AREA B
CODED NOTES
1 THIS LIGHT SHALL BE PROVIDED WITH AN
ADDITIONAL UL925 LISTED TRANSFER DEVICE EQUAL
TO A BODINE GTB, THIS DEVICE SHALL ACCEPT BOTH
THE NORMAL LIGHTING CIRCUIT (WITHIN THIS ROOM)
AND ALSO THE DESIGNATED CIRCUIT FROM THE
E
F
G
H
345 1B 1A
DC
LADDER ACCESS
DCDC
DCDCDC
LI-103- 7 EM2- 2 LI-103- 7
LI-103- 7LI-103- 7LI-103- 7
EM2
LI-103
3,P
MATCHLINE
MATCHLINE
GENERAL NOTES:
A. COORDINATE LOCATION OF LIGHT FIXTURES WITH STRUCTURE AND
MECHANICAL EQUIPMENT AND DUCT WORK TO AVOID CONFLICTS.
B. ALL INDIVIDUAL BATTERY POWERED LIGHTING AND EXIT SIGNS SHALL BE
CONNECTED TO THE SAME BRANCH CIRCUIT SERVING THE NORMAL LIGHTS
AND SHALL BE ON THE LINE SIDE OF RELAYS OR SWITCHING DEVICES.
C. REFER TO KEYED NOTES FOR CONTROL OF ADDITIONAL EMERGENCY LIGHTING.
ALL EXIT SIGNS SHALL BE CONNECTED FOR CONTINUOUS OPERATION.
D. INDUSTRIAL LIGHTING FIXTURES SHOWN IN MECHANICAL ROOMS, ELECTRICAL
ROOMS, TELECOMMUNICATIONS ROOMS, STORAGE AREAS, JANITOR CLOSETS,
AND SHOPS SHALL BE COORDINATED WITH EQUIPMENT PRIOR TO
INSTALLATION TO AVOID ANY CONFLICTS AND PROVIDE MAXIMUM LIGHTING IN
WORKING SPACES.
E. OCCUPANCY SENSORS IN CORRIDORS SHALL CONTROL ALL FIXTURES
INDICATED AND DIM TO 50% WHEN NO OCCUPANCY IS SENSED FOR 30
MINUTES. ALL OTHER OCCUPANCY SENSORS THROUGHOUT THE FACILITY
SHALL TURN ON FIXTURES TO 50% OF FULL LIGHT OUTPUT. OCCUPANT CAN
MANUALLY DIM OR SWITCH THE LIGHTS TO A HIGHER PERCENTAGE OF FULL
LIGHT OUTPUT. UPON SENSING VACANCY FOR 15 MINUTES, THE LIGHTS TURN
OFF.
F. AT LOCATIONS WHERE ROOM LIGHT FIXTURES ARE CONTROLLED THROUGH
THE USE OF OCCUPANCY SENSORS, PROVIDE THE NUMBER OF SENSORS AND
LOCATE THE UNITS AS REQUIRED FOR COMPLETE ROOM COVERAGE. WHERE
MORE THAN ONE SENSOR IS LOCATED IN A COMMON SPACE, CONNECT THE
UNITS SUCH THAT DETECTION OF OCCUPANCY FROM EITHER UNIT WILL
ENERGIZE ALL OF THE LIGHTING. WHERE SWITCHES ARE SHOWN IN
CONJUNCTION WITH OCCUPANCY SENSORS, CONNECT THE SWITCHES TO DE-
ENERGIZE THE LIGHTING INDICATED REGARDLESS OF OCCUPANCY. ADJUST
ALL SENSOR TIME DELAYS AND MOTION SENSITIVITIES DURING PROJECT
CLOSEOUT TO MEET THE OPERATIONAL FUNCTION OF THE OWNER.
G. RECESSED DOWN LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE
PROVIDED WITH ADJUSTABLE T-BAR ATTACHMENT ARMS MANUFACTURED BY
THE LIGHT FIXTURE COMPANY.
H. REFER TO SHEET E-601 FOR LIGHTING FIXTURE SCHEDULE.
I. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
N
E
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:5
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
THIRD FLOOR ELECTRICAL
LIGHTING PLAN - AREA E
EL103-E
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EL103-E
THIRD FLOOR ELECTRICAL
LIGHTING PLAN - AREA E
CODED NOTES
1 UL 924 LISTED EMERGENCY LIGHTING INVERTER,
2.25KVA, 277V INPUT/277V OUTPUT, MINIMUM OF 90
MINUTES OF RUNTIME, QUANTITY OF (5) 20A OUTPUT
BREAKERS. PROVIDE FACTORY STARTUP AND
EXTENDED WARRANTY. UNIT SHALL BE EQUAL TO
MYERS POWER PRODUCT - ILLUMINATOR SERIES.
2 THIS LIGHT SHALL BE PROVIDED WITH AN
ADDITIONAL UL925 LISTED TRANSFER DEVICE EQUAL
TO A BODINE GTB, THIS DEVICE SHALL ACCEPT BOTH
THE NORMAL LIGHTING CIRCUIT (WITHIN THIS ROOM)
AND ALSO THE DESIGNATED CIRCUIT FROM THE
M
M
M
M
M
M
M
J
M
J
J
J
J
J
J
M
M
M M
M
M
M
M
M
M
M
M
M
M M
M
M
M m
M m
J J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
M
M m
M m
M
M m
M m
M
J
J
H
J
K
L
M
56789101C1D 9.2 8.3 7.3 6.9
PT-101
Tool Crib
Jet Engine Inspection Shop
Welding Shop
Fabrication Shop
X-Ray Room
Dark Room
Storage
NDI Inspection Shop
Structures Office
Jet Shop Office
Jet Shop Admin
Corridor
C10
C
C
C C
107.15B
107.18
PL-104
C C
C
Computer / Admin Room
Fabrication Admin
C
C
C
106.3B
PL-101-3
PL-101-7PL-101-9
PL-101-9
PL-101-9
PL-101-7
PL-101-5
PL-101-1
PL-101-1
PL-101-5
PL-101-5
PL-101-1 PL-101-3
PL-101-10
PL-101-7
PL-101-7PL-101-9
PL-101-9
PL-101-5
PL-101- 3
PL-101- 4PL-101- 4PL-101- 4
PL-101-6
PL-101-6
PL-101-2 PL-101-2
PL-101-2
PL-101-10
PL-101-8
PL-101-10
PL-101-8
PL-101-10
PL-101-8
PL-101-12
PL-101-14
PL-101-12
PL-101-14
PL-101-8
PL-101-12
106.1 106.2 PL-109-3
PL-109-5
106.4
106.5
PL-109-3
PL-109-3
PL-109-5
106.6106.7PL-109-5PL-109-3PL-109-5 106.9A 106.8
PL-101-15
PL-101-16
PL-101-15
PL-101-16
PL-101-15
PL-101-16
PL-101-15
PL-101-18
PL-101-17
PL-101-17
PL-101-18
PL-101-17
PL-101-18
PL-101-18
PL-101-17
HP2-B
HP1-A
FC01-A
FC02-A
PL-101-18
PL-101-17
PL-101-16
PL-101-16
PL-101-21
PL-101-20
PL-101-25
PL-101-20
PL-101-21 PL-101-23
PL-101-23
PL-101-23
PL-101-22 PL-101-22
PL-101-25PL-101-25PL-101-20PL-101-20
PL-101-21PL-101-21
C
CC
PL-101-24
PL-101-27
PL-101-24
PL-101-27
PL-101-24
PL-101-27
PL-101-24
PL-101-27
PL-101-30
PL-101-28
PL-101-29
PL-101-28
PL-101-31 PL-101-30 PL-101-26
PL-101-31
PL-101-29PL-101-28PL-101-29
PL-101-30
PL-101-31
COPY
PL-101-31 PL-101-30
PL-109
PT-102
PL-102-8
PL-102-8
PL-102-8
PL-104-20
PL-104-20
PL-104-1
PL-104-2
PL-104-3
PL-104-4
PL-104-1
PL-104-2
PL-104-3
PL-104-4
PL-104-1
PL-104-2
PL-104-3
PL-104-4
PL-104-1
PL-104-2
PL-104-5
PL-104-6
PL-104-7
PL-104-8
PL-104-5
PL-104-6
PL-104-7
PL-104-8
PL-104-5
PL-104-6
PL-104-7
PL-104-8
PL-104-5
PL-104-6
PL-104-21
PL-104-9
PL-104-10
PL-104-11
PL-104-12
PL-104-9
PL-104-10
PL-104-11
PL-104-12
PL-104-9
PL-104-10
PL-104-11
PL-104-12
PL-104-9
PL-104-10
PL-104-11
PL-104-12
PL-104-13
PL-104-14
PL-104-15
PL-104-16
PL-104-13
PL-104-14
PL-104-15
PL-104-16
PL-104-13
PL-104-14
PL-104-15
PL-104-16
PL-104-13
PL-104-14
PL-104-15
PL-104-16
PL-104-17
PL-104-18
PL-104-19
PL-104-17
PL-104-18
PL-104-17
PL-104-19
PL-104-18
PL-104-19
PL-104-17
PL-104-18
PL-104-19
PL-104-21
PL-104-21
EF3EF2
PL-104-20
TV
TV TV
TV
TV
TV
EX. SUMP
PUMP
OHD1
OHD2
OHD3
DH1.1
DH1.2
DH1.3
UH2.11
UH2.5
UH2.8
UH2.6
UH2.2
UH1.1
UH1.2
EX. HD1
PH-202-1,3,5
PH-201-26,28,30
PH-201-25,27,29
PH-201-31,33,35
BW-101
EX. BIG
FAN 2
EX. BIG
FAN 1
UH2.1
106.3A
106.9B
107.11
PH-101
107.12
107.13
107.14
107.15A
107.16A
107.16B
107.17
107.19A
PL-109-15
107.20
107.21
107.22
107.23A
107.23B
107.24
107.25
107.26
107.27
107.28A
107.29A
107.29B
107.28B
107.30
107.16C
UH2.12
EX. EF
BS3
- A
PL-111-11
G,WP
OHD10
OHD11
OHD9
UH2.7
EDH-1A
EDH-1B
BS1-A
PL-104-26
G,WP
PL-104-26
G,WP
M A
T C
H L
IN
E
MATCHLINE
GENERAL NOTES:
A. CONDUIT ROUTING IS SHOWN DIAGRAMMATICALLY AND SHALL BE FULLY
REVIEWED AND COORDINATED WITH ALL OTHER TRADES PRIOR TO
CONSTRUCTION.
B. ALL PENETRATIONS THROUGH THE FLOOR AND EXTERIOR BUILDING WALLS
SHALL BE SEALED WATERTIGHT WITH LINK-SEAL OR EQUIVALENT.
C. REUSE CONDUITS SERVING ROOF-MOUNTED MECHANICAL EQUIPMENT IF
CONDUIT IS IN GOOD CONDITION.
D. REFER TO THE TECHNOLOGY AND FIRE ALARM SHEETS FOR ADDITIONAL POWER
REQUIREMENTS.
E. COORDINATE FINAL MECHANICAL AND PLUMBING EQUIPMENT CONNECTIONS
WITH MECHANICAL AND PLUMBING DRAWINGS.
F. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL FINAL
CONNECTIONS TO ALL HVAC AND PLUMBING EQUIPMENT (BUT NOT LIMITED TO
RTU'S, AHU'S, FANS, DAMPERS, LOUVERS, PUMPS AND CONTROLS).
G. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
H. FOR MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING
E-603.
I. FOR EXISTING MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO
DRAWING E-603.
J. FOR OVERHEAD COILING/OVERHEAD EQUIPMENT CIRCUITING REQUIREMENTS,
REFER TO DRAWING E-603.
K. FOR SHOP EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING E-602.
N A
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:5
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
FIRST FLOOR ELECTRICAL POWER
PLAN - AREA A
EP101-A
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EP101-A
FIRST FLOOR ELECTRICAL
POWER PLAN - AREA A
CODED NOTES
1 EXISTING OVERHEAD DOOR AND ASSOCIATED CONTROLS. MATCH AND
EXTEND EXISTING CONDUIT TO NEW PANEL. REFER TO DRAWING E-603 FOR
CIRCUITIONG AND CONTROL REQUIREMENTS.
2 OVERHEAD DOOR. REFER TO OVERHEAD COILING/ROLL-UP DOOR
ELECTRICAL SCHEDULES FOR CIRCUITING REQUIREMENTS. COORDINATE
EXACT LOCATION OF CONTROLS WITH ARCHITECT.
3 EXISTING FAN AND ASSOCIATED CONTROLS. MATCH AND EXTEND EXISTING
CONDUIT TO NEW PANEL. REFER TO DRAWING E-603 FOR CIRCUITING AND
CONTROL REQUIREMENTS.
4 MOUNT EXISTING EQUIPMENT 15KVA 480V/240V TRANSFORMER ON ADJACENT
WALL.
5 TELECOM GROUND BUS BAR TMGB.
UP
J
J
M
M m
M m
M m
M m
M m
M m
M m
M m
M m
M m
M m
M m
M m
M m
J
J
M
M m
M
J
M m
M m
J
D
E
F
G
H
56789101C1D 9.2 8.3 7.3 6.9
PL-101PL-103
LE-101
LI-101
PL-102
AMXS/CC Office
Orderly Room
Production Room
Accessories Superintendent Office
Women's Toilet
Munitions
Storage
ISO
Office
Open Office
Training
R&R Admin
Mechanical
Mech Room
Women's Locker
Break Room
Mech
MOF/CC Office
MXG/CC Office
MXS/CC Office
MOC OIC Office
MXG/DC Office
Corridor
C12
Entry
Hydraulic Admin
Mens Locker
Mechanical
Corridor
C14
Stair
S1
Hydraulic Office
R&R Office
UDM Office
Training Manager / Testing
Men's Toilet
Corridor
C11 Mother's Room
SIPR
Storage
Corridor
C17
C
C
C
C
C
C
C
C
C
C C
C C
CC
C
C
G,ACT G G,ACT
G
G
Office
IT
RA Office
FC05-A
FC06-A
FC07-A
FC08-A
FC09-A
PL-111
PL-110
FAAP
G,ACT G,ACT
C
C
C
C
C
C
C
TV
TV
COPYTV
TV
TV
G ,M
IC
R
O
G ,R
E F
G ,R
E F
G ,A
C T
G ,A
C
TACT
G ,V
E N
D
G ,V
E N
D
G ,A
C T
G ,A
C T
G ,A
C T
G ,A
C T
TVTV
C
C
TV
TV
C
C C
C
C
C
C
C
CC
TV
TV
COPY
COPY
TV TV TVTV
TV
TV
C TV
C
C
C
C
C C
C
C
CCC
C C
CC
C
C
PL-102-1
PL-102-1
PL-102-1
PL-102-1
PL-102-1
PL-102-3
PL-102-3
PL-102-4
PL-102-2
PL-102-2
PL-102-4
PL-102-4
PL-102-4
PL-102-2
PL-102-3PL-102-3
PL-102-2
PL-102-3 PL-102-3
PL-102-4
PL-102-8
PL-102-5
PL-102-5
PL-102-4
PL-102-5
PL-102-5
PL-102-6
PL-102-7
PL-102-9
PL-102-9
PL-102-32
PL-102-35
PL-102-35
PL-102-32
PL-102-35
PL-102-33
PL-102-31
PL-102-32
PL-102-9
PL-102-36
PL-102-32
PL-102-34
PL-102-34
PL-102-34PL-102-31
PL-102-33
PL-102-6
PL-102-6 PL-102-7
PL-102-6
PL-102-7
PL-102-7
PL-102-6
PL-102-8
PL-102-9
PL-102-9
PL-102-7
PL-102-36
PL-102-33 PL-102-33
PL-102-31 PL-102-30
PL-102-35 PL-102-34 PL-102-32
PL-102-15
PL-102-11
PL-102-14
PL-102-14PL-102-15
PL-102-15
PL-102-15
PL-102-13
PL-102-38
PL-102-10,12
PL-102-14
PL-102-16 PL-102-17 PL-102-18
PL-102-22
PL-102-17 PL-102-18
PL-102-19
PL-102-18
PL-102-21
PL-102-20
PL-102-21
PL-102-19
PL-102-22PL-102-17
PL-102-24 PL-102-24 PL-102-28
PL-102-29 PL-102-28 PL-102-29
PL-102-28PL-102-29
PL-102-29
PL-102-28
PL-102-20
PL-102-18
PL-102-19
PL-102-19
PL-102-22
PL-102-24
PL-102-24
PL-102-25
PL-102-23
PL-102-25
PL-102-23
PL-102-23
PL-102-25
PL-102-29
PL-102-28
PL-102-22
PL-102-18
PL-102-18
PL-102-20
PL-102-26
PL-102-27
PL-102-26
PL-102-27
PL-102-26
PL-102-26
PL-102-27
PL-102-26
PL-102-27
PL-102-27
PL-103-3
PL-103-4
PL-103-3
PL-103-5
PL-103-4
PL-103-5
PL-103-20
PL-103-26
PL-103-25
PL-103-28
PL-103-3
PL-103-3
PL-103-6
PL-103-6
PL-103-20 PL-103-21
PL-103-27
PL-103-25
PL-103-28 PL-103-22
PL-103-24
PL-103-22
PL-103-23
PL-103-2PL-103-1PL-103-2PL-103-1PL-103-2PL-103-1
PL-103-3
PL-103-5
P L -1
-8
P L -1
-1
P L -1
-7
P L -1
-9
PL-103-11
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-1
PL-103-6 PL-103-5
PL-103-20 PL-103-19 PL-103-21
PL-103-21PL-103-20 PL-103-21
PL-103-21
PL-103-21 PL-103-19
PL-103-20
PL-103-20
PL-103-26
PL-103-28PL-103-28
PL-103-27
PL-103-27 PL-103-27 PL-103-26 PL-103-26
PL-103-23
PL-103-24
PL-103-23
PL-103-22
P L -1
-1
TV
PL-103-34
PL-105-1
PL-101-34
PL-101-34PL-101-34
PL-101-32
PL-101-33PL-101-33
PL-103-30
PL-101-33
PL-103-30
PL-103-31
PL-103-31
PL-103-29
PL-101-35
PL-101-35
PL-101-35
PL-101-32
PL-101-33
PL-103-35
PL-103-35
PL-103-32 PL-103-34PL-103-34PL-103-34PL-103-34 PL-103-32
PL-103-33
PL-103-35 PL-103-25
PL-101-34
PL-101-32PL-103-35
PL-101-34PL-103-35PL-101-34
PL-101-33PL-101-33
PL-101-35PL-101-35
PL-101-33
PL-103-32PL-103-33PL-103-32PL-103-33
PL-101-33
PL-101-35
PL-103-31
PL-103-30
PL-103-31
PL-103-33
CC
PL-105-1
FC13-B
TV
TV
FC19-A
FC18-A
FC16-B
FC17-B
CUH-1F
CUH-1A
AC1
BS2
- A
PL-111-11
PL-111-11
G,WP
G,WP
RCP1
GWH1
GWH2
AC2
S1
RAD1
EX. MDA
DH-205-2,4,6
SWB-MSB
EM1
PL-101-19
GUH1.1
GUH1.2
PL-104-26
G,WP
PL-104-26
G,WP
PL-108-7
G,WPPL-108-7
PL-103-36,38
PL-102-13
PL-102-14
MATCHLINE
MATCHLINE
GENERAL NOTES:
A. CONDUIT ROUTING IS SHOWN DIAGRAMMATICALLY AND SHALL BE FULLY
REVIEWED AND COORDINATED WITH ALL OTHER TRADES PRIOR TO
CONSTRUCTION.
B. ALL PENETRATIONS THROUGH THE FLOOR AND EXTERIOR BUILDING WALLS
SHALL BE SEALED WATERTIGHT WITH LINK-SEAL OR EQUIVALENT.
C. REUSE CONDUITS SERVING ROOF-MOUNTED MECHANICAL EQUIPMENT IF
CONDUIT IS IN GOOD CONDITION.
D. REFER TO THE TECHNOLOGY AND FIRE ALARM SHEETS FOR ADDITIONAL POWER
REQUIREMENTS.
E. COORDINATE FINAL MECHANICAL AND PLUMBING EQUIPMENT CONNECTIONS
WITH MECHANICAL AND PLUMBING DRAWINGS.
F. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL FINAL
CONNECTIONS TO ALL HVAC AND PLUMBING EQUIPMENT (BUT NOT LIMITED TO
RTU'S, AHU'S, FANS, DAMPERS, LOUVERS, PUMPS AND CONTROLS).
G. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
H. FOR MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING
E-603.
I. FOR EXISTING MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO
DRAWING E-603.
J. FOR OVERHEAD COILING/OVERHEAD EQUIPMENT CIRCUITING REQUIREMENTS,
REFER TO DRAWING E-603.
K. FOR SHOP EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING E-602.
N
B
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:0
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
FIRST FLOOR ELECTRICAL POWER
PLAN - AREA B
EP101-B
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EP101-B
FIRST FLOOR ELECTRICAL
POWER PLAN - AREA B
CODED NOTES
1 MAIN ELECTRICAL EQUIPMENT GROUND BUS BAR.
2 GROUND TEST WELL.
3 PROVIDE 3/4" X 10" COPPER CLAD GROUND ROD. (TYPICAL)
4 TELECOM GROUND BUS BAR TMGB.
5 LIGHTING CONTACTOR FOR EXTERIOR LIGHTS. REUSE EXISTING EXTERIOR
LIGHTING CONTROLS.
6 EXISTING TO REMAIN 400MHZ FREQUENCY CONVERTER.
7 MOUNT RECEPTACLE ABOVE SERVER RACK. COORDIANTE RECEPTACLE TYPE
WITH SERVER RACK MANUFACTURER.
MMM
M
M
M
M
J J J
M
M
J
M M
M
J
M
M m
J
M
M M
M
M
M m
M m
M
M
A
B
C
D
56789101C1D 9.2 8.3 7.3 6.9
C.4
LI-102
PL-108
PT-103
Battery Shop
Hydraulic Shop
Repair & Rec/Wheel & Tire Shop
AGE Office
Corridor
C13
Testing Shop
Entry
C
C
1 1 1 1
PL-105
PL-105-1PL-105-1
PL-105-1
PL-105-1
G,WP
130.1
G,WP
PL-105-4
PL-105-4 PL-105-4
PL-105-4
PL-105-4
PL-105-9
PL-105-2
PL-105-2
PL-105-6
PL-105-7
PL-105-6
PL-105-7
PL-105-6
PL-105-7
PL-105-6
PL-105-3
PL-105-8
PL-105-9PL-105-8PL-105-8
PL-105-9PL-105-8
PL-105-10PL-105-11
PL-105-10 PL-105-11
PL-105-5 PL-105-5
PL-105-3
PL-105-2 PL-105-2
PL-105-7
PL-105-5
PL-105-5
PL-105-13
PL-105-12
PL-105-13
PL-105-12
AGE Shop
132.1
132.2
132.3
132.4
133.2
133.1
133.3
133.4
PL-105-23
PL-105-23
PL-105-23
PL-105-25
PL-105-25
PL-105-22
PL-105-23
PL-105-24
PL-105-24
PL-105-22
PL-105-24
PL-105-22
PL-105-27
134.1
PL-105-28
PL-105-26
PL-105-28
PL-105-27
PL-105-28
PL-105-26
PL-105-27
PL-105-26
PL-105-27
PL-105-26
PL-105-26
135.1
FC20-B
OHD4
OHD5 OHD6 OHD7 OHD8
UH2.9
UH2.10
UH2.3
CUH-1A
EX. HD 7
PH-203-1,3,5
HVLV3.2
HVLV3.1
HVLV3.4
EF8
EF7
134.2
DH2.1
DH2.2
DH2.3
DH2.4
PH-201-7,9,11
PH-201-14,16,18 PH-201-13,15,17 PH-201-20,22,24
PH-201-19,21,23
UH2.4
PL-111-11
G,WP
OHD12
OHD13
HVLV3.3
PL-108-7
G,WP
PL-108-7
G,WP
MATCHLINE
M A
T C
H L
IN
E
UH1.3
GENERAL NOTES:
A. CONDUIT ROUTING IS SHOWN DIAGRAMMATICALLY AND SHALL BE FULLY
REVIEWED AND COORDINATED WITH ALL OTHER TRADES PRIOR TO
CONSTRUCTION.
B. ALL PENETRATIONS THROUGH THE FLOOR AND EXTERIOR BUILDING WALLS
SHALL BE SEALED WATERTIGHT WITH LINK-SEAL OR EQUIVALENT.
C. REUSE CONDUITS SERVING ROOF-MOUNTED MECHANICAL EQUIPMENT IF
CONDUIT IS IN GOOD CONDITION.
D. REFER TO THE TECHNOLOGY AND FIRE ALARM SHEETS FOR ADDITIONAL POWER
REQUIREMENTS.
E. COORDINATE FINAL MECHANICAL AND PLUMBING EQUIPMENT CONNECTIONS
WITH MECHANICAL AND PLUMBING DRAWINGS.
F. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL FINAL
CONNECTIONS TO ALL HVAC AND PLUMBING EQUIPMENT (BUT NOT LIMITED TO
RTU'S, AHU'S, FANS, DAMPERS, LOUVERS, PUMPS AND CONTROLS).
G. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
H. FOR MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING
E-603.
I. FOR EXISTING MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO
DRAWING E-603.
J. FOR OVERHEAD COILING/OVERHEAD EQUIPMENT CIRCUITING REQUIREMENTS,
REFER TO DRAWING E-603.
K. FOR SHOP EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING E-602.
N
C
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:1
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
FIRST FLOOR ELECTRICAL POWER
PLAN - AREA C
EP101-C
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EP101-C
FIRST FLOOR ELECTRICAL
POWER PLAN - AREA C
CODED NOTES
1 EXISTING OVERHEAD DOOR AND ASSOCIATED CONTROLS. MATCH AND EXTEND
EXISTING CONDUIT TO NEW PANEL. REFER TO DRAWING E-603 FOR
CIRCUITIONG AND CONTROL REQUIREMENTS.
2 OVERHEAD DOOR. REFER TO OVERHEAD COILING/ROLL-UP DOOR ELECTRICAL
SCHEDULES FOR CIRCUITING REQUIREMENTS. COORDINATE EXACT LOCATION
OF CONTROLS WITH ARCHITECT.
3 RELOCATED NAE-15 RUNWAY LIGHTING PANEL. MATCH AND EXTEND ALL
CONDUIT AND CONDUCTORS TO NEW LOCATION.
m
M
M
J
J
M m
M m
M m
M M
M
M
M
M m
J
H
J
K
L
M
345 1B 1A
E&E Maintenance
E&E
Avionics
Office
Stair
S2
Test Room
E&E Office
Secure Room
169Office
Entry
C
C
C
C
C
C
DR
DR DR
DR
PL-106-1 PL-106-3
PL-106-7
PL-106-7
PL-106-7
PL-106-5
PL-106-5 PL-106-5
PL-106-5
PL-106-2 PL-106-4 PL-106-2 PL-106-4 PL-106-2 PL-106-4
TV
TV
TV
TVTV
COPY
PL-106-9
PL-106-12PL-106-9
P L -1
-1
PL-106-17 PL-106-17
PL-106-17
PL-106-8 PL-106-6
PL-106-12
PL-106-10
PL-106-12
PL-106-20
PL-106-26
PL-106-28
PL-106-26
PL-106-28
PL-106-23 PL-106-21
PL-106-22
PL-106-24
PL-106-22
PL-106-24
PL-106-19
PL-106-19
PL-106-25
PL-106-10 PL-106-10
PL-106-11
PL-106-11
PL-106-13
PL-106-10
PL-106-20
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-1
P L -1
-2
PL-106-30
PL-106-19 PL-106-19
PL-106-25
PL-106-22
PL-106-20
PL-106-26
PL-106-30
PL-106-25
PL-106-21
PL-106-21PL-106-23PL-106-23
PL-106-13
PL-106-25
PL-106-27
PL-106-27
PL-106-27
PL-106-27
G,WP
G,WP
G,WP
G,WP
HP3-C
PL-102-9
HP4-D
FC21-C
AC1-M
CUH-1B
FC22-C
FC23-C
EF5
EX. HD2 EX. HD3
EX. HD4
EX. HD5
EX. HD6
PH-202-2,4,6 PH-202-7,9,11
PH-202-8,10,12
PH-202-13,15,17
PH-202-14,16,18
BS5
- C
PL-107-23
PL-107-23
G,WP
G,WP
OHD14
EDH-1C
M A
T C
H L
IN
E
MATCHLINE
GENERAL NOTES:
A. CONDUIT ROUTING IS SHOWN DIAGRAMMATICALLY AND SHALL BE FULLY
REVIEWED AND COORDINATED WITH ALL OTHER TRADES PRIOR TO
CONSTRUCTION.
B. ALL PENETRATIONS THROUGH THE FLOOR AND EXTERIOR BUILDING WALLS
SHALL BE SEALED WATERTIGHT WITH LINK-SEAL OR EQUIVALENT.
C. REUSE CONDUITS SERVING ROOF-MOUNTED MECHANICAL EQUIPMENT IF
CONDUIT IS IN GOOD CONDITION.
D. REFER TO THE TECHNOLOGY AND FIRE ALARM SHEETS FOR ADDITIONAL POWER
REQUIREMENTS.
E. COORDINATE FINAL MECHANICAL AND PLUMBING EQUIPMENT CONNECTIONS
WITH MECHANICAL AND PLUMBING DRAWINGS.
F. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL FINAL
CONNECTIONS TO ALL HVAC AND PLUMBING EQUIPMENT (BUT NOT LIMITED TO
RTU'S, AHU'S, FANS, DAMPERS, LOUVERS, PUMPS AND CONTROLS).
G. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
H. FOR MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING
E-603.
I. FOR EXISTING MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO
DRAWING E-603.
J. FOR OVERHEAD COILING/OVERHEAD EQUIPMENT CIRCUITING REQUIREMENTS,
REFER TO DRAWING E-603.
K. FOR SHOP EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING E-602.
N D
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:1
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
FIRST FLOOR ELECTRICAL POWER
PLAN - AREA D
EP101-D
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EP101-D
FIRST FLOOR ELECTRICAL
POWER PLAN - AREA D
CODED NOTES
1 OVERHEAD DOOR. REFER TO OVERHEAD COILING/ROLL-UP DOOR ELECTRICAL
SCHEDULES FOR CIRCUITING REQUIREMENTS. COORDINATE EXACT LOCATION
OF CONTROLS WITH ARCHITECT.
2 GROUND BAR FOR OWNER PROVIDED GROUND MAT. COORDINATE EXACT
LOCATION WITH OWNER AND GROUND MAT VENDOR.
J
M m
M m
M m
M m
J
M m
M m
J
J
M m
D
E
F
G
H
345 1B 1A
PL-107PL-106
Secure Room
Men's
163 Women's
Supply
IT
AMU Open Office
Maintenance Hangar
Corridor
C15 Stair
S3
Debrief
Corridor
C16
Entry
Elevator
E1
G ,E
W C
G ,E
W C
G
Janitor
BPL-201-25
BPL-201-26,28
Flight Chiefs
Entry
PL-107-4
PL-106-27
G,WP
PL-107-10
BPL-201-23
PL-107-4 PL-107-11
PL-107-2
PL-107-9
PL-107-9
PL-107-12
PL-107-14
PL-107-13
PL-107-10
PL-107-15
PL-107-16
PL-107-12
PL-107-14
PL-107-17
PL-107-7
PL-107-5
PL-107-7
PL-107-6
PL-107-6
PL-107-4 PL-107-8
PL-107-11PL-107-10
BPL-201-20
PL-107-12 PL-107-13 PL-107-15
PL-107-12
PL-107-13 PL-107-15
PL-107-2
PL-107-3PL-107-3PL-107-9
PL-107-1 PL-107-1 PL-107-1
PL-205-19
PL-107-5PL-107-5PL-107-7PL-107-16PL-107-14PL-107-12PL-107-16
PL-107-17PL-107-19
PL-107-8
PL-107-6
BPL-201-22,24 PL-107-2
P L -2
-1
P L -2
-9
G
G
PL-107-2PL-107-10
C
C
CC
C
C
C
PL-107-21
PL-107-21
PL-107-21
PL-107-21
PL-107-21
C
PL-102-32
FC30-D
FC29-C
CUH-1C
CUH-1D
CUH-1E
FC28-C
FC27-C
Elevator Equip
159 EX. GENERATOR
EX. EMTS
EWH1
BS6
- C
PL-107-23
PL-107-25
PL-107-25
G,WP
G,WP
G,WP
RCP2
PL-205-12
G
G
PL-205-16,18,20
PL-205-14
EX. MDA
DH-205-2,4,6
BPL-201-27
EDH-1D
G,WP
G,WP
G,WP
PL-104-26
G,WP
PL-104-26
G,WP
G,WP
G,WP
G,ACT
ACT
PL-107-20
PL-107-18
ACTACTACT
BPL-201-30
BPL-201-32
BPL-201-32
PL-107-22
MATCHLINE
MATCHLINE
GENERAL NOTES:
A. CONDUIT ROUTING IS SHOWN DIAGRAMMATICALLY AND SHALL BE FULLY
REVIEWED AND COORDINATED WITH ALL OTHER TRADES PRIOR TO
CONSTRUCTION.
B. ALL PENETRATIONS THROUGH THE FLOOR AND EXTERIOR BUILDING WALLS
SHALL BE SEALED WATERTIGHT WITH LINK-SEAL OR EQUIVALENT.
C. REUSE CONDUITS SERVING ROOF-MOUNTED MECHANICAL EQUIPMENT IF
CONDUIT IS IN GOOD CONDITION.
D. REFER TO THE TECHNOLOGY AND FIRE ALARM SHEETS FOR ADDITIONAL POWER
REQUIREMENTS.
E. COORDINATE FINAL MECHANICAL AND PLUMBING EQUIPMENT CONNECTIONS
WITH MECHANICAL AND PLUMBING DRAWINGS.
F. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL FINAL
CONNECTIONS TO ALL HVAC AND PLUMBING EQUIPMENT (BUT NOT LIMITED TO
RTU'S, AHU'S, FANS, DAMPERS, LOUVERS, PUMPS AND CONTROLS).
G. HATCHED AREA IS NOT IN CONTRACT UNLESS NOTED OTHERWISE.
H. FOR MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING
E-603.
I. FOR EXISTING MECHANICAL EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO
DRAWING E-603.
J. FOR OVERHEAD COILING/OVERHEAD EQUIPMENT CIRCUITING REQUIREMENTS,
REFER TO DRAWING E-603.
K. FOR SHOP EQUIPMENT CIRCUITING REQUIREMENTS, REFER TO DRAWING E-602.
N
E
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/2 /2
:5
:2
A
M C
R e v it L o c a l\
H a n g a r8
E a le ja n d ro
.a lm a n z a a e c o m
.c o m .r v t
Rickenbacker ANG Base, Renovate Hangar 885
ACM #60443615
FIRST FLOOR ELECTRICAL POWER
PLAN - AREA E
EP101-E
P# NLZG102008
R A
/D H
A A
R A
/D H
12.19.2017
0 4 8 162
1/8" = 1'-0"
EP101-E
FIRST FLOOR ELECTRICAL
POWER PLAN - AREA E
CODED NOTES
1 TELECOM GROUND BUS BAR TGB.
2 TAP BOX WITH CAM-STYLE RECEPTACLE. COORDINATE EXACT LOCATION
WITH OWNER.
3 PROVIDE 3#10+1#10 GND IN 3/4" CONDUIT FROM 208V/30A/3P LOCKABLE
DISCONNECT WITH SHUNT TRIP TO CIRCUIT SHOWN.
4 ELEVATOR PIT RECEPTACLE.
5 STARTER DISCONNECT FOR GARBAGE DISPOSAL. LOCATED MOTOR RATED
SWITCH NEXT TO SINK ABOVE COUNTER.
6 MOUNT RECEPTACLE ABOVE SERVER RACK. COORDIANTE RECEPTACLE
TYPE WITH SERVER RACK MANUFACTURER.
M M
M
M
M
A
B
C
D
345 1B 1A
C.4
EX. HD8 EX. HD9
EX. HD10
EX. HD11
EX. HD12
PH-203-2,4,6 PH-203-7,9,11
PH-203-8,10,12
PH-203-13,15,17
PH-203-14,16,18
PL-107-25
G,WP
MATCHLINE
M A
T C
H L
IN
E
GENERAL NOTES:
A. CONDUIT ROUTING IS SHOWN DIAGRAMMATICALLY AND SHALL BE FULLY
REVIEWED AND COORDINATED WITH ALL OTHER TRADES PRIOR TO
CONSTRUCTION.
B. ALL…