Amendment_4_ARCH_-_7.17.2018.pdf
PDF 5 MB Posted
- Attached to
- Renovate Hangar 885 Federal contract opportunity
- Solicitation number
- W9136418B5000
About this file
arch drawing
View the file
Other files for this federal contract opportunity
Show all 45
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F.H.
H H
J J
K K
L L
M M
1C
1C
1D
1D
9.2
9.2
8.3
8.3
7.3
7.3
6.9
6.9
K.2 K.2
J.5 J.5
H.8 H.8
H.1 H.1
8.4
8.4
D02
D05 D05 D05 D05
D14
D27
M A
T C
H L
IN
E
D17
D22
D23
D32
D39
D31
D31
D31
D32 D39
D51
D39
8'
6'
D50
D31
8" 5'
2'
D39 D39
D02
D13
DEMOLITION FLOOR PLAN LEGEND
DENOTES FLOOR SLAB REMOVAL AND EXCAVATION
REQUIRED FOR INSTALLATION OF NEW WORK; REFER TO
KEY NOTES ON NEW WORK PLANS FOR ADDITIONAL
INFORMATION ON THE NATURE OF THE NEW WORK
ITEM TO BE DEMOLISHED; REFER TO KEYNOTE FOR
ADDITIONAL INFORMATION
MASONRY PARTITION TO BE DEMOLISHED; TO BE REMOVED
FULL HEIGHT, U.N.O. REFER TO KEYNOTE IF APPLICABLE
DENOTES EXTENT OF INTERIOR ROOF DEMOLITION FOR NEW
WORK; REFER TO KEY NOTES ON NEW WORK PLANS FOR
ADDITIONAL INFORMATION ON THE NATURE OF THE NEW WORK
METAL FRAMING / GYP BD PARTITION TO BE DEMOLISHED
EXISTING DOOR AND HARDWARE ONLY TO BE
DEMOLISHED, FRAME TO REMAIN
EXISTING DOOR, FRAME, AND HARDWARE TO BE
DEMOLISHED
DENOTES TOPPING FLOOR SLAB REMOVAL (2" OR 4"); REFER
TO KEY NOTES ON NEW WORK PLANS FOR ADDITIONAL
INFORMATION ON THE NATURE OF THE NEW WORK
DENOTES EXTERIOR PAVING TO BE REMOVED AND / OR
MODIFIED. REFER TO CIVIL DRAWINGS FOR MORE INFORMATION.
DEMOLITION GENERAL NOTES
A. THE SCOPE OF DEMOLITION WORK IS A FULL "GUT" RENOVATION WITH THE
EXCEPTION OF WALLS AND BUILDING SHELL STRUCTURE. WALLS TO REMAIN / BE
DEMOLISHED ARE SHOWN IN THE DEMOLITION PLAN. ALL CEILINGS. FLOORING
FINISH, PLUMBING, PLUMBING FIXTURES, ELECTRICAL, ELECTRICAL FIXTURES /
EQUIPMENT, MECHANICAL PIPING / DUCTWORK / EQUPMENT.
B. REFER TO THE SPECIFICATIONS FOR MORE INFORMATION ON SELECTIVE
DEMOLITION AND ASBESTOS ABATEMENT.
C. REFER TO CIVIL, PLUMBING, MECHANICAL, AND ELECTRICAL DEMOLITION DRAWINGS
FOR MORE INFORMATION ON DEMOLITION OF THOSE SYSTEMS AND EQUIPMENT.
D. CODED NOTES SHOWN IN THE SHEDULE MAY NOT BE USED ON THIS SHEET.
E. STRUCTURAL GRID FOR NEW CONSTRUCTION NOT SHOWN ON DEMOLITION PLANS.
F. SLAB CUTS SHOWN ON THE DEMOLITION PLANS ARE APPROXIMATE AND BASED ON
INFORMATION OBTAINED FROM RECORD DRAWINGS. EXACT EXTENT OF SLAB
REMOVAL MUST BE FIELD VERIFIED BY CONTRACTOR.
G. OWNER WILL REMOVE ALL SHOP EQUIPMENT AND LOOSE FURNISHINGS PRIOR TO
CONSTRUCTION
H. BUILDING WILL NOT BE IN OPERATION DURING CONSTRUCTION.
I. AT LOCATIONS OF EXISTING OPENINGS TO BE INFILED WITH NEW CMU INFILL, NEW
WORK SHALL BE "TOOTHED" INTO EXISTING MASONRY WALLS AS INDICATED ON
STRUCTURAL DRAWINGS.
J. DEMOLITION DRAWINGS ARE BASED ON AVAILABLE INFORMATION PROVIDED BY THE
OWNER AND FROM FIELD INVESTIGATIONS AND MAY NOT REPRESENT ALL EXISTING
CONDITIONS.
K. SURFACES DAMAGED DURING DEMOLITION AND / OR CONSTRUCTION ARE TO BE
PATCHED AND REPAIRED AS REQUIRED AND FINISHED TO MATCH ADJACENT AREAS.
L. DIMENSIONS ASSOCIATED WITH DEMOLITION WORK MUST BE FIELD VERIFIED.
M. ALL ITEMS SHOWN WITH DASHED LINES SHALL BE REMOVED AND DISPOSED OF
UNLESS NOTED OTHERWISE.
N. ALL DEMOLITION WORK TO BE COORDINATED WITH NEW CONSTRUCTION WORK AS
SHOWN ON ALL OTHER DRAWINGS.
O. ALL SLAB REMOVALS FOR NEW WORK SHALL BE INFILLED UP TO THE FINISH FLOOR
HEIGHT OF THE ADJACENT FLOORS.
P. CONTRACTOR IS REQUIRED TO REMOVE ALL INTERIOR BUILDING SIGNAGE AND
PATCH / INFILL ALL HOLES IF IN EXISTING WALL TO REMAIN.
Q. REMOVE ALL WALL MOUNTED ITEMS (SHELVING, BRACKINGS, MIRRORS, MARKER
BOARDS, TACK BOARDS, ETC) AND PATCH AS NEEDED IF WALL IS TO REMAIN.
R. ALL PENETRATIONS THROUGH INTERIOR CAPS / ROOFS AND INTERIOR CMU WALLS
NO LONGER BEING USED (MEP PENETRATIONS, ETC) TO BE PATCHED / INFILLED THE
SAME AS THE ADJACENT MATERIAL UNLESS NOTED OTHERWISE.
S. THE BUILDING OWNER, OANG, HAS A GOAL OF 95% OF WAST BEING DIVERTED FROM
THE LAND FILL.
N A
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/1
/2
:5
:5
P
M C
P ro g ra m F ile s \A u to d e s k \P ro je c ts
\6
H a n g a r8
A a n d re w .h u b e r.
rv t
Rickenbacker ANG Base, Renovate Hangar 885
P#60443615
FIRST FLOOR DEMOLITION PLAN -
AREA A
AD101-A
P#NLZG102008
A H
/B S
A H
/B S
B S
01.13.2017
0 4 8 162
1/8" = 1'-0"AD101-A
1 FIRST FLOOR DEMOLITION PLAN - AREA A
NO. CODED NOTES - DEMOLITION
D33 CENTER NEW OPENING AT CENTER POINT OF STRUCTURAL BAY
D34 NOTE THAT THE DEMOLITION OF THIS WALL REQUIRES A NEW WALL TO BE INFILLED
BETWEEN THE LOW AND HIGH ROOF ABOVE, REFER TO ROOF DETAIL
D35 REMOVE EXISTING CRANE RAIL & BRIDGE
D36 REMOVE EXISTING CRANE
D37 REMOVE EXISTING STAIR STRUCTURE
D38 EXISTING FIRE SUPRESSION RISERS TO REMAIN
D39 REMOVE EXISTING CONCRETE SLABS IN THIS LOCATION FOR UNDERGROUND PLUMBING
WORK, REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION
D40 REMOVE EXISTING EXTERIOR WINDOW BEHIND SIDING, OPENING TO BE REUSED FOR NEW
MECHANICAL LOUVERS
D41 REMOVE EXISTING EXTERIOR SIDING IN LOCATION OF REMOVED WINDOW
D42 REMOVE EXISTING LOUVER, SEE ELEVATIONS AND MECHANICAL DRAWINGS
D43 REMOVED ELECTRICAL EQUIPMENT, REFER TO ELECTRIC DRAWINGS FOR MORE
INFORMATION
D44 REMOVE EXISTING HANGAR SLAB IN THIS AREA FOR ELEVATOR PIT AND HOISTWAY WALL
FOOTINGS
D45 REMOVE EXISTING CASEWORK
D46 EXISTING ASPHALT TO BE REMOVED IN THIS AREA, REFER TO CIVIL DRAWINGS FOR MORE
INFORMATION
D47 MODIFY EXISTING TRENCH DRAIN, REFER TO CIVIL DRAWINGS FOR MORE INFORMATION
D48 REMOVE EXISTING WALL TO CREATE NEW OPENING FOR NEW OVERHEAD DOOR
D49 SLAB REMOVAL FOR REMOVAL AS REQUIRED FOR REMOVAL OF FOUNDATIONS FOR
EXISTING STAIR WALLS BEING REMOVED
D50 REMOVE EXISTING SHRUBS AND TREES, REFER TO CIVIL DRAWINGS FOR MORE
INFORMATION ON THE NATURE OF THE WORK
D51 MECHANICAL UNIT AND PAD TO BE REMOVED, REFER TO MECHANICAL DRAWINGS FOR
MORE INFORMATION
D52 REMOVE EXISTING FOAM FIRE SUPPRESSION GENERATOR AND STRUCTURE AND
RELOCATE PER FIRE SUPPRESSION DRAWINGS
D53 EXISTING FOAM FIRE SUPPRESSION LINES TO BE RAISED TO BOTTOM OF HANGAR
STRUCTURE, REFER TO FIRE SUPPRESSION DRAWINGS FOR MORE INFORMATION
D54 REMOVE EXISTING 4" SLOPED TOP COATING FLOOR SLAB IN THIS LOCATION
D55 REMOVE BRIDGE CRANE RAIL VERTICAL SUPPORTS, TYP
D56 ROOF BELOW, REFER TO SECOND FLOOR DEMOLITION PLAN FOR DEMOLITION
INFORMATION ON THIS ROOF
D57 EXISTING FOAM FIRE SUPPRESSION GENERATOR AND STRUCTURE TO REMAIN, REFER TO
FIRE SUPPRESSION DRAWINGS FOR MORE INFORMATION
D58 REMOVE EXISTING WALL FOR NEW OPENING TO ELEVATOR, HEIGHT OF OPENING IS 7'-4"
FROM FINISH FLOOR
D59 REMOVE EXISTING WINDOW AND PREP OPENING FOR NEW METAL LOUVER, REFER TO
ELEVATIONS AND MECHANICAL DRAWINGS FOR MORE INFORMATION
D60 REMOVE EXISTING ROOF AND STRUCTURAL DECKING IN THIS LOCATION FOR NEW
MECHANICAL PENETRATION. REMOVE ROOFING MATERIAL ABOVE DECK (INSULATION,
BUILT UP ROOFING, ETC) 2" LARGER THAN OPENING IN DECK TO ALLOW FOR NEW STEEL
PLATE COVER BEARING. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION.
NO. CODED NOTES - DEMOLITION
D01 REMOVE EXISTING PORTION OF CMU WALL AS NEEDED TO PLACE NEW FOOTINGS FOR
MECHANICAL PLATFORM COLUMNS. REMOVED PORTION OF CMU TO BE REPLACED WITH
NEW
D02 REMOVE EXISTING WALL FOR NEW DOOR OPENING, SEE DOOR SCHEDULE FOR OPENING
DIMENSIONS
D03 REMOVE EXISTING ENTIRE HANGAR FLOOR SLAB IN THIS LOCATION TO ALLOW FOR
CONSTRUCTION OF NEW WALLS AND FOOTINGS
D04 REMOVE EXISTING 2" TOP COATING FLOOR SLAB IN THIS LOCATION
D05 REMOVE EXISTING CONCRETE RAMP
D06 REMOVE EXISTING ROOF ACCESS LADDER
D07 REMOVE EXISTING COILING DOOR
D08 REMOVE EXISTING WINDOW AND FRAME
D09 REMOVE EXISTING EXTERIOR GLASS DOOR AND GLASS FROM
D10 REMOVE EXISTING OVERHEAD DOOR
D11 REMOVE EXISTING TOILET PARTITION, TYPICAL THROUGHOUT
D12 REMOVE EXISTING TOILET FIXTURE/SINK, TYPICAL THROUGHOUT
D13 REMOVE EXISTING OVERHEAD DOOR AND HARDWARE, OPENING TO BE PARTIALLY INFILLED
WITH NEW SMALLERS OVERHEAD DOOR AND MAN DOOR
D14 COMPLETELY REMOVE EXISTING CEILING AND ANY ASSOCIATED GRID, HANGERS ENTIRELY
IN THIS ROOM
D15 REMOVE THE EXTENT OF LADDER TO ABOVE THE NEW ROOF ELEVATION
D17 REMOVE EXISTING WIRE MESH WALL AND FRAME
D18 REMOVE EXISTING BOLLARDS IN THIS LOCATION
D20 REMOVE ENTIRE PORTION OF EXISTING ROOF STRUCTURE IN THIS AREA
D21 REMOVE ROOF HATCH AND LADDER; SEE DETAILS ON NEW WORK PLANS FOR COVERING
OPENING AND REROOFING
D22 REMOVE EXISTING CHAIN LINK CAGE AND METAL ROOF
D23 REMOVE VCT FLOORING
D24 REMOVE PORTION OF EXISTING WALL FOR NEW ELEVATOR HOISTWAY ENCLOSURE
D25 REMOVE CONCRETE MECHANICAL PAD
D26 REMOVE GRAVEL BALASTED ROOF SYSTEM. SAVE GRAVEL BALAST AS NEEDED TO
REPLACE. SEE NEW CONSTRUCTION DETAIL.
D27 REMOVE EXISTING LOUVER AND PREP OPENING FOR NEW LOUVER, SEE ELEVATIONS AND
MECHANICAL DRAWINGS
D28 REMOVE SLAB IN THIS AREA AND PREPARE FOR INSTALLATION OF RECESSED 3/4" WALK
OFF MAT THAT WILL BE LEVEL WITH SURROUNDING FINISH FLOOR
D29 REMOVE PORTITION OF WALL FOR NEW WINDOW OR DOOR, SEE FLOOR PLAN AND WINDOW
AND WINDOW TYPES FOR MORE INFORMATION
D30 REMOVE EXISTING ROOF AND STRUCTURAL DECKING IN THIS LOCATION FOR
CONSTRUCTION OF MECHANICAL PLATFORM STRUCTURAL COLUMNS. REMOVE ROOFING
MATERIAL ABOVE DECK (INSULATION, BUILT UP ROOFING, ETC) 2" LARGER THAN OPENING
IN DECK TO ALLOW FOR NEW STEEL PLATE COVER BEARING. REFER TO STRUCTURAL
DRAWINGS FOR MORE INFORMATION.
D31 GRIND / SAW CUT EXISTING SLAB AS REQUIRED TO MAINTAIN PLACING THICKNESS FOR
NEW RAMPS, TYPICAL. REFER TO TYPICAL CONCRETE DETAILS ON STRUCTURAL
DRAWINGS FOR MORE INFORMATION
D32 REMOVE EXISTING FLOOR SLAB IN THIS LOCATION FOR MECHANICAL PLATFORM
STRUCTURE. REFER TO STRUCTURAL DETAIL FOR AMOUNT OF SLAB TO BE REMOVED FOR
PLACEMENT OF NEW FOUNDATIONS AND SLABS
I/R DATE DESCRIPTION
1 17 JULY 2018 AMENDMENT 4
APPROXIMATE OVERALL DIMENSION
428' - 8"
A P
P R
O X
IM
A
T E
O V
E R
A
LL
D
IM
E N
S
IO
N
1'
ROOF BELOW TO REMAIN
ROOF BELOW TO REMAIN
ROOF BELOW TO REMAIN
ROOF EDGE FLASHING TO BE
REMOVED AND REPLACED AFTER
ROOF HAS BEEN REPLACED.
TYPICAL ON ENTIRE ROOF. SEE
PHOTOS OF EXISTING CONDITIONS
DEMOLITION ROOF PLAN LEGEND
EXISTING PENTHOUSE LOUVERS
TO REMAIN
EXISTING LOUVER PENTHOUSES TO BE
DEMOLISHED. PENTHOUSES ARE
APPROXIMATELY 7' TALL AND WEIGH 250
LBS. COORDINATE WITH MECHANICAL
EXISTING LIGHTS TO BE DEMOLISHED,
MOUNTING STRUCTURE TO REMAIN.
COORDINATE WITH ELECTRICAL
ROOF MEMBRANE AND INSULATION
TO BE REMOVED DOWN TO
STRUCTURAL DECK
EXHAUST FANS TO BE REMOVED. DECK
TO BE COVERED WITH NEW TO MATCH
EXISTING, INFILL INSULATION TO MATCH
EXISTING AND ROOF WITH NEW.
COORDINATE WITH MECHANICAL
EXTERIOR ROOF REPLACEMENT GENERAL NOTES
A. SCOPE OF EXTERIOR ROOF WORK IS ESSENTIALLY A LIKE FOR LIKE REPLACEMENT OF
EXISTING MEMBRANCE ROOF AND INSULATION WITH THE EXCEPTION THAT THE NEW ROOF
IS A WHITE MEMBRANE ROOF. DECKING AND STRUCTURE TO REMAIN UNLESS DAMAGED
AND NEED REPLACEMENT.
B. EDGE ROOF FLASHING TO BE REMOVED AND REPLACED.
C. SCOPE ALSO TO INCLUDE TEAR OFF INSULATION, NAILERS, FLASHINGS, ETC.)
D. ROOF REPLACEMENT DESCRIBED ON THIS SHEET IS ONLY FOR THE MAIN HANGAR SHELL
BUILDING EXTERIOR ROOF. OTHER ROOFING WORK DESCRIBED ELSEWHERE.
E. FIELD SURVEYS WERE NOT CONDUCTED BY THE AE TEAM FOR THE EXTERIOR ROOF.
CONTRACTOR SHOULD FIELD VERIFY EXISTING CONDITIONS TO GRASP THE SCOPE. SEE
PICTURES OF EXISTING CONDITIONS ON THIS SHEET.
F. SEE PROJECT MANUAL FOR MORE INFORMATION.
N A
B
C
D
E
F
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/1
/2
:5
:5
P
M C
P ro g ra m F ile s \A u to d e s k \P ro je c ts
\6
H a n g a r8
A a n d re w .h u b e r.
rv t
Rickenbacker ANG Base, Renovate Hangar 885
P#60443615
ROOF DEMOLITION PLAN -
EXTERIOR
AD141
P#NLZG102008
A H
/B S
A H
/B S
B S
01.13.2017
0 8 16 324
1/16" = 1'-0"AD141
1 ROOF DEMOLITION PLAN - EXTERIOR
I/R DATE DESCRIPTION
1 17 JULY 2018 AMENDMENT 4
NOT TO SCALEAD141
2 EXISTING ROOF PHOTOS
F.H. F.H.
H H
J J
K K
L L
M M
1C
1C
1D
1D
9.2
9.2
8.3
8.3
7.3
7.3
6.9
6.9
K.2 K.2
J.5 J.5
H.8 H.8
H.1 H.1
8.4
8.4
Tool Crib
Jet Engine Inspection
Shop
Welding Shop
Fabrication Shop
X-Ray Room
Dark Room
Storage
NDI Inspection Shop
Structures Office
Jet Shop Office
Jet Shop Admin
Corridor
C10
Computer / Admin Room
Fabrication Admin
A503
8.5
8.5
8.7
8.7
9.4
9.4
H.15 H.15
H.4 H.4
H.6 H.6
102B
106A
106B
101C
102A 101A 101B
143 144
101D
110B
110A
105103 104
102C
A403
A404
100E
A201 2
W4W4
A301
A501
A501
SIM
A501
SIM
A501
SIM
W6
MATCHLINE
M A
T C
H L
IN
E
CALLOUT FLOOR PLAN GENERAL NOTES
A. DO NOT SCALE DRAWINGS.
B. FURNITURE AND SHOP EQUIPMENT SHOWN FOR REFERENCE ONLY AND IS N.I.C.
C. SHOP EQUIPMENT SHOWN FOR REFERENCE ONLY AND IS A BY OWNER ITEM. FOR MORE
SHOP EQUIPMENT INFORMATION, REFER TO ENLARGED SHOP PLANS
D. REFER TO CONSTRUCTION PLANS FOR CODED NOTES, LEGENDS, DIMENSIONS, AND
WALL TAGS
E. NEW COLUMN GRIDS ONLY SHOWN ON AREA PLANS IF THEIR ASSOCIATED STRUCTURAL
ELEMENT IS ALSO LOCATED IN SAME AREA.
N A
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/1
/2
:5
:4
P
M C
P ro g ra m F ile s \A u to d e s k \P ro je c ts
\6
H a n g a r8
A a n d re w .h u b e r.
rv t
Rickenbacker ANG Base, Renovate Hangar 885
P#60443615
FIRST FLOOR CALLOUT PLAN -
AREA A
A102-A
P#NLZG102008
A H
/B S
A H
/B S
B S
01.13.2017
0 4 8 162
1/8" = 1'-0"A102-A
1 FIRST FLOOR CALLOUT PLAN - AREA A
E E
F F
G G
H H
1B
1B
1A
1A
1.9
1.9
H.1 H.1
E.9 E.9
Secure Briefing
MOC
QA
Plans & Sch.
Women
Counseling
Analysis
Men
QA Office
MOC Secure
9' - 0"
GYP BD
9' - 0"
GYP BD9' - 0"
ACT - 2X4
8' - 0"
ACT - 2X4
8' - 0"
ACT - 2X4
10' - 0"
ACT - 2X4
10' - 0"
ACT - 2X4
EXP STR
12' - 8"
Stair
S2
Stair
S3
Elevator
E1
Storage
EXP STR
12' - 8"
C02
2.8
2.8
1.2
1.2
1.1
1.1
H.3 H.3
C02
C02
EXP STR
(EXIST HT)
8' - 0"
ACT - 2X4
8' - 0"
ACT - 2X4
9' - 0"
ACT - 2X4
9' - 0"
ACT - 2X4
9'
A C
T
X
9' - 0"
ACT - 2X4
9' - 0"
ACT - 2X4
C02
C02
EXP STR
12' - 3" (EXIST)
MATCHLINE
MATCHLINE
C07
C07
CEILING PLAN GENERAL NOTES
A. DO NOT SCALE DRAWINGS.
B. CODED NOTES SHOWN ON SCHEDULE MAY NOT BE USED ON THIS SHEET.
C. COORDINATE TYPE AND SIZE OF LIGHT FIXTURES, DIFFUSERS, HVAC EQUIPMENT,
AND SPRINKLERS WITH MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
D. CEILING GRIDS SHALL BE CENTERED IN RESPECTIVE ROOMS UNLESS NOTED
OTHERWISE.
E. ALL ACOUSTICAL TILE AND GYPSUM BOARD CEILINGS TO BE 10'-0" UNLESS NOTED
OTHERWISE.
F. SEE ELECTRICAL DRAWINGS FOR TYPE OF LIGHT FIXTURES AND
COMMUNICATIONS DEVICES.
G. SEE MECHANICAL DRAWINGS FOR TYPE OF DIFFUSERS.
H. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD LOCATIONS.
I. CEILING HEIGHTS ARE RELATIVE TO FINISH FLOOR WITHIN THAT SPACE.
J. SPACES WITH NO CEILINGS NOTED AS "EXP STR" AND REFER TO AN EXISTING
UNDERSIDE OF DECK, LIST AN APPROXIMATE HEIGHT. IN SOME CASES IT MAY
VARY DUE TO A SLOPING DECK. IN THE CASE OF A SLOPING DECK, THE
APPROXIMATE HEIGHT LISTED IS ITS HIGHEST POINT. INTERIOR ROOF PLAN
SHOWS WHICH AREAS ARE SLOPING.
REFLECTED CEILING PLAN SYMBOLS
DOWN LIGHT FIXTURE
HVAC DIFFUSER / PERFORATED GRILLE, SUPPLY AIR
- SEE MECHANICAL DRAWINGS FOR MORE
INFORMATION
HVAC DIFFUSER / PERFORATED GRILLE, RETURN
AIR - SEE MECHANICAL DRAWINGS FOR MORE
INFORMATION
EXIT SIGNAGE
HVAC LINEAR DIFFUSER - SEE MECHANICAL FOR
MORE INFORMATION
2' x 2' ACCESS PANEL
CEILING MOUNTED PROJECTOR LOCATION
WALL-MOUNTED LIGHT FIXTURE
RECESSED/FLUSH-MOUNTED LIGHT
FIXTURE
LAY-IN LED LIGHT FIXTURE
PENDANT "UP DOWN" LIGHT FIXTURE
SEMI-RECESSED DECORATIVE LIGHT FIXTURERECESSED CIRCULAR HVAC SUPPLY DIFFUSER -
SEE MECHANICAL FOR MORE INFORMATION
OCCUPANCY SENSOROS
NEW FAN, SEE MECHANICAL DRAWINGS
FOR MORE INFORMATION
N
E
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/1
/2
:5
:4
P
M C
P ro g ra m F ile s \A u to d e s k \P ro je c ts
\6
H a n g a r8
A a n d re w .h u b e r.
rv t
Rickenbacker ANG Base, Renovate Hangar 885
P#60443615
SECOND FLOOR CEILING PLAN -
AREA E
A122-E
P#NLZG102008
A H
/B S
A H
/B S
B S
01.13.2017
0 4 8 162
1/8" = 1'-0"A122-E
1 SECOND FLOOR CEILING PLAN - AREA E
NO. CODED NOTES - FLOOR PLAN
C01 EXISTING CRANE TRACK
C02 GYP BD BULKHEAD
C03 EXISTING FAN TO REMAIN
C04 NEW METAL PANEL BETWEEN EXISTING HANGAR WALL AND NEW INTERIOR WALL
C05 FIRE SUPPRESSION FOAM GENERATOR
C06 NEW BULKHEAD FOR OPERABLE PARTITION WALL
C07 ROLLER SHADES OVER THIS WINDOW
APPROXIMATE OVERALL DIMENSION
428' - 8"
A P
P R
O X
IM
A
T E
O V
E R
A
LL
D
IM
E N
S
IO
N
1'
37' - 8"
37' - 8"
ROOF BELOW TO REMAIN
ROOF BELOW TO REMAIN
ROOF BELOW TO REMAIN
PREFABRICATED
CANOPY ROOF BELOW
NEW MEMBRANE ROOF
EXTERIOR ROOF PLAN LEGEND
NEW LOUVER PENTHOUSES IN PLACE OF
REMOVED PENTHOUSES. INTENDED TO BE A
"LIKE FOR LIKE" REPLACEMENT.
NEW LED LIGHTS IN EXISTING MOUNTING
STRUCTURE.
EXTERIOR ROOF REPLACEMENT GENERAL NOTES
A. SCOPE OF EXTERIOR ROOF WORK IS ESSENTIALLY A LIKE FOR LIKE REPLACEMENT OF
EXISTING MEMBRANCE ROOF AND INSULATION WITH THE EXCEPTION THAT THE NEW ROOF
IS A WHITE MEMBRANE ROOF. DECKING AND STRUCTURE TO REMAIN UNLESS DAMAGED
AND NEED REPLACEMENT.
B. EDGE ROOF FLASHING TO BE REMOVED AND REPLACED.
C. SCOPE ALSO TO INCLUDE TEAR OFF INSULATION, NAILERS, FLASHINGS, ETC.)
D. ROOF REPLACEMENT DESCRIBED ON THIS SHEET IS ONLY FOR THE MAIN HANGAR SHELL
BUILDING EXTERIOR ROOF. OTHER ROOFING WORK DESCRIBED ELSEWHERE.
E. FIELD SURVEYS WERE NOT CONDUCTED BY THE AE TEAM FOR THE EXTERIOR ROOF.
CONTRACTOR SHOULD FIELD VERIFY EXISTING CONDITIONS TO GRASP THE SCOPE. SEE
PICTURES OF EXISTING CONDITIONS ON THIS SHEET.
F. SEE PROJECT MANUAL FOR MORE INFORMATION.
N A
B
C
D
E
F
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/1
/2
:5
:5
P
M C
P ro g ra m F ile s \A u to d e s k \P ro je c ts
\6
H a n g a r8
A a n d re w .h u b e r.
rv t
Rickenbacker ANG Base, Renovate Hangar 885
P#60443615
ROOF PLAN - EXTERIOR
A141
P#NLZG102008
A H
/B S
A H
/B S
B S
01.13.2017
0 8 16 324
1/16" = 1'-0"A141
1 ROOF PLAN - EXTERIOR
I/R DATE DESCRIPTION
N A
B
C
D
E
F
PROJECT
CLIENT
CONSULTANT
CONSULTANTS
REGISTRATION
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
CLIENT PROJECT NUMBER
L a s t P lo tt e d
F ile n a m e
Printed on ___% Post-Consumer Recycled Content Paper
A R
C H
E x
P ro je c t M a n a g e m e n t In it ia ls
D e s ig n e r:
C h e c k e d
A p p ro v e d
123456
A
B
C
D
E
6 5 4 3 2 1
100% DESIGN SET
Ohio Air National Guard 7370 Minuteman Way
Columbus, Ohio 43217
614.492.4459 tel www.goang.com
AECOM
277 W. Nationwide Blvd.
Columbus, Ohio 43215
614.464.4500 tel www.aecom.com
A
B
C
D
E
FE
N
T R
A N
C E
S
ID
E
A
IR
S
ID
E
/1
/2
:5
:5
P
M C
P ro g ra m F ile s \A u to d e s k \P ro je c ts
\6
H a n g a r8
A a n d re w .h u b e r.
rv t
Rickenbacker ANG Base, Renovate Hangar 885
P#60443615
DOOR SCHEDULES
A602
P#NLZG102008
A H
/B S
A H
/B S
B S
01.13.2017
ID ROOM DOOR FRAME
LABEL
HDW
SET
DETAILS
COMMENTSMARK TYPE
SIZE MATERI
AL TYPE MATERIAL FINISH HEAD JAMB SILLWIDTH HEIGHT THICKNESS
166C Avionics F 6' - 0" 7' - 0" 1 3/4" HM 4 HM HM ----- 7 2/A504 3/A504 1/A504 ACCESS CONTROL W/ CARD READER
167 Office NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 21 H2/A604 J2/A604 -----
168 Office NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 21 H2/A604 J2/A604 -----
169 Secure Room F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 37 H2/A604 J2/A604 -----
170 E&E NLFR 6' - 0" 7' - 0" 1 3/4" HM 4 HM HM 45 MIN 17 H3/A604 J3/A604 -----
171 E&E Office NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 22 H2/A604 J2/A604 -----
172A E&E Maintenance F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM ----- 61 H2/A604 J2/A604 -----
172B E&E Maintenance OH-C (FR) 8' - 0" 10' - 0" 2" MT ----- ----- ----- 60 MIN ----- H5/A604 J5/A604 ----- OVERHEAD COILING DOOR
173 Test Room F 6' - 0" 7' - 0" 1 3/4" HM 4 HM HM ----- 56 H2/A604 J2/A604 -----
174 Mechanical Room F 6' - 0" 7' - 0" 1 3/4" HM 4 HM HM ----- 57 EXISTING EXISTING EXISTING NEW DOOR AND HARDWARE IN EXISTING FRAME
201A Secure Briefing NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 20 H1/A604 J1/A604 ----- CYPHER LOCK
201B Secure Briefing NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
202A MOC NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 20 H1/A604 J1/A604 ----- CYPHER LOCK
202B MOC NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 33 H1/A604 J1/A604 -----
203 MOC Secure F 3' - 0" 7' - 0" 1 3/4" HM 1 HM HM ----- 23 H1/A604 J1/A604 ----- ACCESS CONTROL W/ CARD READER - SCIF LOCK
204 Plans & Sch. NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 20 H1/A604 J1/A604 ----- CYPHER LOCK
205A QA NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 22 H1/A604 J1/A604 -----
205B QA NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
206 QA Office NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
207 Analysis NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 22 H1/A604 J1/A604 -----
210 Women F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 25 H2/A604 J2/A604 -----
211 Men F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 26 H2/A604 J2/A604 -----
212 Counseling NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
213 Storage NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 37 H1/A604 J1/A604 -----
214 Supply NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 37 H1/A604 J1/A604 -----
215 AMXS Chief NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
216 EMF Chief NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
217 CRF Chief NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
218 MOF Chief NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
219 First Sgt NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
220 First Sgt NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
221 Consult NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 29 H1/A604 J1/A604 -----
222 Maint. Officers NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 29 H1/A604 J1/A604 -----
223A Conference / Standup Room
HG 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM
----- 30
H1/A604 J1/A604 -----
223B Conference / Standup Room
HG 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM
----- 29
H1/A604 J1/A604 -----
224A Electrical Closet F 3' - 0" 7' - 0" 1 3/4" HM 1 HM HM 45 MIN 31 H1/A604 J1/A604 -----
224B Electrical Closet F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 45 MIN 31 H2/A604 J2/A604 -----
E1 Elevator ----- EH1/A604 EJ1/A604 ES1/A604 ELEVATOR DOOR
E2 Elevator ----- EH1/A604 EJ1/A604 ES1/A604 ELEVATOR DOOR
ID ROOM DOOR FRAME
LABEL
HDW
SET
DETAILS
COMMENTSMARK TYPE
SIZE MATERI
AL TYPE MATERIAL FINISH HEAD JAMB SILLWIDTH HEIGHT THICKNESS
001 Entry FG 3' - 0" 7' - 0" 1 3/4" AL 5 AL AL ----- 3 11/A504 10/A504 6/A504 NEW DOOR, FRAME, AND HARDWARE IN EXISTING OPENING
002A Entry F 6' - 0" 7' - 0" 1 3/4" AL 4 AL AL ----- 4 EXISTING EXISTING EXISTING NEW DOOR, FRAME, AND HARDWARE IN EXISTING OPENING
002B Entry F 4' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 36 H2/A604 J2/A604 -----
003 Entry F 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 9 EXISTING EXISTING EXISTING NEW DOOR, FRAME, AND HARDWARE IN EXISTING OPENING
004A Entry FG 6' - 0" 7' - 0" 1 3/4" AL/GL 6 AL AL ----- 4 12/A504 10/A504 7/A504
004B AMU Open Office FG 6' - 0" 7' - 0" 1 3/4" AL/GL 6 AL AL ----- 52 H7/A604 J7/A604 -----
005 Entry F 5' - 0" 7' - 2" 1 3/4" HM EXISTING EXISTING PTD ----- 8 EXISTING EXISTING EXISTING NEW DOOR AND HARDWARE IN EXISTING FRAME
006 Mech Room F 6' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD ----- 35
EXISTING EXISTING EXISTING NEW DOOR AND HARDWARE IN EXISTING FRAME, ACCESS
CONTROL W/CARD READER
010 Corridor F 4' - 0" 7' - 0" 1 3/4" HM 2 HM HM 45 MIN 2 H2/A604 J2/A604 ----- ACCESS CONTROL W/ CARD READER
011 Corridor F 6' - 0" 7' - 0" 1 3/4" WD 4 HM HM ----- 38 H2/A604 J2/A604 -----
013 Corridor F 4' - 0" 7' - 2" 1 3/4" HM 2 HM HM 45 MIN 2 H3/A604 J3/A604 ----- ACCESS CONTROL W/ CARD READER
015 Corridor F 5' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD ----- 39 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
016A Corridor NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 40 H1/A604 J1/A604 -----
016B Corridor F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 45 MIN 14 H2/A604 J2/A604 ----- ACCESS CONTROL W/ CARD READER
020A Stair F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 60 MIN 1 H3/A604 J3/A604 ----- ACCESS CONTROL W/ CARD READER
020B Stair F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 60 MIN 58 H2/A604 J2/A604 -----
030A Stair F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 60 MIN 1 H2/A604 J2/A604 ----- ACCESS CONTROL W/ CARD READER
030B Corridor F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 60 MIN 53 H2/A604 J2/A604 -----
040 Corridor F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 60 MIN 58 H2/A604 J2/A604 -----
100A Maintenance Hangar F 3' - 0" 7' - 2" 1 3/4" HM EXISTING EXISTING PTD ----- 54 EXISTING EXISTING EXISTING NEW DOOR AND HARDWARE IN EXISTING FRAME
100B OH-S 12' - 0" 7' - 4" 2" MT EXISTING EXISTING PTD ----- ----- 16/A504 15/A504 EXISTING OVERHEAD SECTIONAL DOOR
100C Maintenance Hangar F 3' - 0" 7' - 2" 1 3/4" HM EXISTING EXISTING PTD ----- 10 EXISTING EXISTING EXISTING NEW DOOR AND HARDWARE IN EXISTING FRAME
100D F 3' - 0" 7' - 2" 1 3/4" HM EXISTING EXISTING PTD ----- 32 EXISTING EXISTING EXISTING NEW DOOR AND HARDWARE IN EXISTING FRAME
100E F 3' - 0" 7' - 2" 1 3/4" HM EXISTING EXISTING PTD ----- 32 EXISTING EXISTING EXISTING NEW DOOR AND HARDWARE IN EXISTING FRAME
101A Tool Crib F 6' - 0" 7' - 0" 1 3/4" HM 4 HM HM ----- 12 H2/A604 J2/A604 ----- ACCESS CONTROL W/ CARD READER
101B Tool Crib OH-C (COUNTER) 8' - 0" 3' - 10" 2" MT ----- ----- ----- ----- ----- H4/604 J4/604 S1/A604 OVERHEAD COILING COUNTER DOOR
101C Tool Crib OH-C (FR) 8' - 0" 12' - 0" 2" MT ----- ----- ----- 60 MIN ----- H4/604 J4/604 ----- OVERHEAD COILING DOOR
101D Tool Crib OH-C (FR) 8' - 0" 10' - 0" 2" MT ----- ----- ----- ----- ----- H4/604 J4/604 ----- OVERHEAD COILING DOOR
102A Jet Engine Inspection Shop
F 6' - 0" 7' - 0" 1 3/4" HM 4 HM HM
----- 51
H2/A604 J2/A604 -----
102B Jet Engine Inspection Shop
OH-S 16' - 0" 14' - 0" 2" MT ----- ----- -----
16/A504 15/A504 EXISTING OVERHEAD SECTIONAL DOOR
102C Jet Engine Inspection Shop
F 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM
----- 54
2/A504 3/A504 1/A504
103 Jet Shop Office NL 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 21 H2/A604 J2/A604 -----
104 Jet Shop Admin NL 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 21 H2/A604 J2/A604 -----
105 Computer / Admin Room
HG 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM
----- 29
H2/A604 J2/A604 -----
106A Welding Shop F 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 55 H2/A604 J2/A604 -----
106B Welding Shop OH-C 8' - 0" 10' - 0" 2" MT ----- ----- ------ ----- ----- H4/A604 J4/A604 ----- OVERHEAD COILING DOOR
107 Fabrication Shop F 6' - 0" 7' - 0" 1 3/4" HM 4 HM HM ----- 56 H2/A604 J2/A604 -----
110A NDI Inspection Shop HG 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 29 H2/A604 J2/A604 -----
110B NDI Inspection Shop F 3' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD ----- 6 EXISTING EXISTING EXISTING NEW DOOR AND HARDWARE IN EXISTING FRAME
111 Storage F 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 46 EXISTING EXISTING -----
112 Structures Office HG 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 29 H2/A604 J2/A604 -----
113 Fabrication Admin NL 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 29 H2/A604 J2/A604 -----
114 IT F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM ----- 37 H2/A604 J2/A604 -----
115 Mechanical F 6' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD ----- 41 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
116A Training Manager / Testing
NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM
----- 21
H2/A604 J2/A604 -----
116B Training Manager / Testing
F 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM
----- 21
H1/A604 J1/A604 -----
117A Production Room NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 43 H2/A604 J2/A604 -----
117B Production Room NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 30 H2/A604 J2/A604 -----
118 Orderly Room NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 42 H2/A604 J2/A604 -----
119 RA Office NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 21 H2/A604 J2/A604 -----
120 UDM Office NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 22 H2/A604 J2/A604 -----
121 Storage F 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 46 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
122 Open Office NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 29 H2/A604 J2/A604 -----
123 MXG/DC Office NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
124 MOC OIC Office NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
125 MXS/CC Office NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
126 MXG/CC Office NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
127 AMXS/CC Office NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
128 MOF/CC Office NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM ----- 21 H1/A604 J1/A604 -----
129 SIPR F 3' - 0" 7' - 0" 1 3/4" WD 3 HM HM ----- 24 H1/A604 J1/A604 ----- ACCESS CONTROL W/ CARD READER - SCIF LOCK
130A AGE Shop F 6' - 0" 7' - 2" 1 3/4" HM EXISTING EXISTING PTD ----- 50 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
130B AGE Shop F 5' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD ----- 5 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
130C AGE Shop F 3' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD ----- 45 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
131 AGE Office F 3' - 0" 7' - 2" 1 3/4" HM EXISTING EXISTING PTD ----- 21 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
132 Battery Shop F 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 49 H2/A604 J2/A604 -----
133 Repair & Rec/Wheel & Tire Shop
F 6' - 0" 7' - 2" 1 3/4" HM 4 HM HM
----- 51
H2/A604 J2/A604 -----
134A Hydraulic Shop F 6' - 0" 7' - 2" 1 3/4" HM 4 HM HM ----- 16 H2/A604 J2/A604 -----
134B Hydraulic Shop OH-C (FR) 8' - 0" 10' - 0" 2" MT ----- ----- ----- 60 MIN ----- H5/A604 J5/A604 ----- OVERHEAD COILING DOOR
135A Testing Shop F 3' - 0" 7' - 2" 1 3/4" HM 2 HM HM ----- 43 H2/A604 J2/A604 -----
135B Testing Shop OH-C 8' - 0" 10' - 0" 2" MT ----- ----- ----- ----- ----- H4/A604 J4/A604 ----- OVERHEAD COILING DOOR
136 R&R Admin HG 3' - 0" 7' - 2" 1 3/4" WD 2 HM HM ----- 30 H2/A604 J2/A604 -----
137 R&R Office F 3' - 0" 7' - 2" 1 3/4" WD 1 HM HM ----- 22 H1/A604 J1/A604 -----
138 Hydraulic Admin HG 3' - 0" 7' - 2" 1 3/4" WD 2 HM HM ----- 30 H2/A604 J2/A604 -----
139 Hydraulic Office F 3' - 0" 7' - 2" 1 3/4" WD 1 HM HM ----- 22 H1/A604 J1/A604 -----
140 Break Room FG 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 45 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
141A Training NL 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 44 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
141B Training NLFR 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM 45 MIN 14 EXISTING EXISTING ----- ACCESS CONTROL W/ CARD READER
141C Training NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 43 H2/A604 J2/A604 -----
142 Accessories Superintendent Office
NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM
----- 21
H2/A604 J2/A604 -----
143 Fabrication Supervisor NL 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 21 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
144 Women's Toilet F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 27 H2/A604 J2/A604 -----
146 Mother's Room F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 28 H2/A604 J2/A604 -----
147 Men's Toilet F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 27 H2/A604 J2/A604 -----
148 Mens Locker F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 45 MIN 14 H2/A604 J2/A604 ----- ACCESS CONTROL W/ CARD READER
149 Storage F 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 46 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
150 Munitions F 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 46 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
151 Mechanical F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM ----- 46 H2/A604 J2/A604 -----
152A ISO NLFR 6' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD 45 MIN 15 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
152B Corridor F 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM ----- 13 H2/A604 J2/A604 ----- ACCESS CONTROL W/ CARD READER
153 Office NL 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 48 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
154 Office NL 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 48 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
155 Mech F 5' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD 45 MIN 47 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
156 IT F 3' - 0" 7' - 2" 1 3/4" HM EXISTING EXISTING PTD 45 MIN 59 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
157A AMU Open Office NLFR 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 45 MIN 19 H2/A604 J2/A604 ----- ACCESS CONTROL W/ CARD READER
157B AMU Open Office NL 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 43 H1/A604 J1/A604 -----
157D AMU Open Office NL 3' - 0" 7' - 0" 1 3/4" WD 1 HM HM 60 MIN 42 H1/A604 J1/A604 -----
158 Flight Chiefs NL 3' - 0" 7' - 0" 1 3/4" WD EXISTING EXISTING PTD ----- 30 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
159 Elevator Equip F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM 60 MIN 62 H2/A604 J2/A604 -----
160 Debrief FG 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 21 H2/A604 J2/A604 -----
161 Supply FG 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 37 H2/A604 J2/A604 -----
162 Women's F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 27 H2/A604 J2/A604 -----
163 Men's F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 27 H2/A604 J2/A604 -----
164 Janitor F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 34 H2/A604 J2/A604 -----
165 Secure Room F 3' - 0" 7' - 0" 1 3/4" HM EXISTING EXISTING PTD 45 MIN 60 EXISTING EXISTING ----- NEW DOOR AND HARDWARE IN EXISTING FRAME
166A Avionics NLFR 3' - 0" 7' - 0" 1 3/4" HM 2 HM HM 45 MIN 18 H3/A604 J3/A604 -----
166B Avionics F 3' - 0" 7' - 0" 1 3/4" WD 2 HM HM ----- 61 H2/A604 J2/A604 -----
I/R DATE DESCRIPTION
File details come from the government source that posted it.