09651 - Resilient Tile Flooring and Accesories.DOC

DOC document 41 KB Posted

Attached to
Award to Chance Construction on 22 Aug 09
Solicitation number
W912L109R0038
Issued by

About this file

RESILIENT TILE FLOORING AND ACCESSORIES

View the file

Other files

File Type Posted
QUESTIONS AND ANSWERS LA PORTE as of 21 JUL 09.doc DOC document
QUESTIONS AND ANSWERS LA PORTE AS OF 20 JUL 09.doc DOC document
QUESTIONS AND ANSWERS as of 8 Jul 09.doc DOC document
QUESTIONS AND ANSWERS as of 7 Jul 09.doc DOC document
QUESTIONS AND ANSWERS as of 6 JUL 09.doc DOC document
Addendum 2 Dimensioned Floor Plans 20090701.pdf PDF
QUESTIONS AND ANSWERS LA PORTE AS OF 29 JUN 09 —
9- Exhibit C 12-05.doc DOC document
Exhibit D-E-F Jan 08.doc DOC document
8 -Exhibit B 1205.doc DOC document
QUESTIONS AND ANSWERS as of 1 JUL 09.doc DOC document
08110-Steel Doors Frames.DOC DOC document
ATTENDANCE ROSTER.pdf PDF
PREPROPOSAL MEETING MINUTES - LA PORTE FACILITIES.doc DOC document
PHOTOS.doc DOC document
Hurricane IKE B 1359 Drawings 20090506.pdf PDF
09512-Accoustical Ceiling.doc DOC document
09680 - Carpet.DOC DOC document
07210-Building Insulation.DOC DOC document
01001-00-General_Requirements.doc DOC document
01731-00-Cutting_ _Patching.DOC DOC document
01019-00-Contract_Considerations.DOC DOC document
AF Form 3052 Construction Cost Estimate Breakdown.xls XLS spreadsheet
Form WH-347-Wage report Form-BlanK.xls XLS spreadsheet
07620-Sheet Metal Flashing and Trim.DOC DOC document
01420-00-Environmental_Protection.doc DOC document
01700-00-Contract_Closeout.DOC DOC document
01300-00-Submittals 20090302.doc DOC document
09900 - Painting.doc DOC document
07591-Preparation for Reroofing 20090227 .doc DOC document
Contractor_Security_Policy_Letter.doc DOC document
Form 3065-Contract Progress Report.xls XLS spreadsheet
07550-Modified Bitumin Roofing 20090226.doc DOC document
Form 3064- Progress Schedule.xls XLS spreadsheet
09255-Gypsum Board Assemblies.DOC DOC document
07560-Cold Coal Tar Modified 20090227.doc DOC document
01105-00-Haz_Mat_Procedures.doc DOC document
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ellington Field ANGB

Houston, Texas

Copyright 2000, The American Institute of Architects (AIA)

SECTION 09651

RESILIENT FLOOR TILE, WALL BASE, AND ACCESSORIES

This Section uses the term "Architect." Change this term to match that used to identify the design professional as defined in the General and Supplementary Conditions.

Verify that Section titles referenced in this Section are correct for this Project's Specifications; Section titles may have changed.

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.

1.2 SUMMARY

A. This Section includes the following:

Adjust list below to suit Project.

1. Vinyl composition tile (VCT).

2. Resilient wall base and accessories.

1.3 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Samples for Initial Selection: For each type of product indicated.

Delete paragraph above if colors and other characteristics are preselected and specified or scheduled. Retain first paragraph and subparagraph below with or without above.

C. Samples for Verification: Full-size units of each color and pattern of resilient floor tile required.

Delete subparagraph below if resilient wall base or accessories are not specified in this Section.

1. Resilient Wall Base and Accessories: Manufacturer's standard-size Samples, but not less than 12 inches (300 mm) long, of each resilient product color and pattern required.

D. Maintenance Data: For resilient products to include in maintenance manuals.

1.4 DELIVERY, STORAGE, AND HANDLING

A. Store resilient products and installation materials in dry spaces protected from the weather, with ambient temperatures maintained within range recommended by manufacturer, but not less than 50 deg F (10 deg C) or more than 90 deg F (32 deg C). Store tiles on flat surfaces.

1.5 PROJECT CONDITIONS

A. Maintain temperatures within range recommended by manufacturer, but not less than 70 deg F (21 deg C) or more than 95 deg F (35 deg C), in spaces to receive floor tile during the following time periods:

1. 48 hours before installation.

2. During installation.

3. 48 hours after installation.

B. After postinstallation period, maintain temperatures within range recommended by manufacturer, but not less than 55 deg F (13 deg C) or more than 95 deg F (35 deg C).

C. Close spaces to traffic during floor covering installation.

D. Close spaces to traffic for 48 hours after floor covering installation.

E. Install resilient products after other finishing operations, including painting, have been completed.

1.6 EXTRA MATERIALS

Extra materials may not be allowed for publicly funded projects.

A. Furnish extra materials described below that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

Revise subparagraphs below to suit Project.

1. Floor Tile: Furnish 1 box for every 50 boxes or fraction thereof, of each type, color, and pattern of floor tile installed.

2. Resilient Wall Base and Accessories: Furnish not less than 10 linear feet (3 linear m) for every 500 linear feet (150 linear m) or fraction thereof, of each type, color, pattern, and size of resilient product installed.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

See Editing Instruction No. 1 in the Evaluations for cautions about naming manufacturers and products.

A. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the products listed in other Part 2 articles.

Retain above for nonproprietary or below for semiproprietary specification. Refer to Division 1 Section "Product Requirements."

2.2 COLORS AND PATTERNS

If retaining second option below, indicate colors and patterns with manufacturers' product designations in other Part 2 articles or in a separate schedule.

A. Colors and Patterns: As selected from manufacturer's full range.

Copy and re-edit articles below for each type of resilient floor tile required. Insert a unique designation for each product required.

2.3 VINYL COMPOSITION TILE

A. Vinyl Composition Tile (VCT): ASTM F 1066.

1. Armstrong World Industries, Inc.

2. Azrock Commercial Flooring, DOMCO.

3. Congoleum Corporation.

4. Mannington Mills, Inc..

5. Tarkett Inc.

For proprietary or semiproprietary specification, delete descriptive requirements from remainder of Article that are determined by product designations inserted above.

B. Wearing Surface: Smooth.

A limited number of products are available in 3/32- and 3/16-inch (2.4- and 4.8-mm) thicknesses; if applicable, insert in first paragraph below.

C. Thickness: 0.125 inch (3.2 mm).

D. Size: 12 by 12 inches (305 by 305 mm).

E. Fire-Test-Response Characteristics:

NFPA 101, "Life Safety Code," requires that floor covering materials in exits and in accesses to exits meet critical radiant flux limitations in certain occupancies. Authorities having jurisdiction may impose other restrictions. Delete paragraph above and subparagraph below if not applicable or revise to suit Project.

1. Critical Radiant Flux Classification: Class I, not less than 0.45 W/sq. cm per ASTM E 648.

2.4 RESILIENT WALL BASE

A. Wall Base: Product complying with FS SS-W-40, Type II and with requirements specified in Resilient Tile Flooring Schedule on the Drawings. Color and pattern in accordance with Schedule.

1. Armstrong World Industries, Inc.

2. Azrock Commercial Flooring, DOMCO.

3. Burke Mercer Flooring Products.

4. Johnsonite.

5. Roppe Corporation.

For proprietary or semiproprietary specification, delete descriptive requirements from remainder of Article that are determined by product designations inserted above.

Both types of rubber base are generally 0.125 inch (3.2 mm) thick; however, some manufacturers offer various thicknesses. Vinyl base is available in both thickness options in first paragraph below but not from every manufacturer.

B. Minimum Thickness: 0.125 inch (3.2 mm).

C. Height: 4 inches (102 mm).

Coordinate height selected above with length selected below; some manufacturers do not offer coils for every height.

D. Lengths: Cut lengths 48 inches (1219 mm) long or coils in manufacturer's standard length.

E. Outside Corners: Premolded.

F. Inside Corners: Job formed.

G. Surface: Smooth.

2.5 RESILIENT MOLDING ACCESSORIES

A. Description: [Cap for cove carpet] [Cap for cove resilient sheet floor covering] [Carpet bar for tackless installations] [Carpet edge for glue-down applications] [Nosing for carpet] [Reducer strip for resilient floor covering] [Joiner for tile and carpet] <Insert description>.

1. Burke Mercer Flooring Products.

2. Johnsonite.

3. Marley Flexco (USA), Inc.

4. Roppe Corporation.

5. Stoler Industries.

For proprietary or semiproprietary specification, delete descriptive requirements from two paragraphs below that are determined by product designations inserted above.

B. Material: Vinyl.

C. Profile and Dimensions: As indicated.

2.6 INSTALLATION MATERIALS

A. Trowelable Leveling and Patching Compounds: Latex-modified, portland cement based or blended hydraulic cement based formulation provided or approved by resilient product manufacturer for applications indicated.

B. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated.

Delete paragraph below if resilient stair accessories are not specified in this Section.

Delete below if only resilient edge strips are required.

C. Metal Edge Strips: Extruded aluminum with mill finish of width shown, of height required to protect exposed edges of tiles, and in maximum available lengths to minimize running joints.

PART 3 - EXECUTION

3.1 EXAMINATION

Coordinate requirements specified in other Sections for subfloor construction and tolerances to ensure that they are appropriate for resilient products selected.

A. Examine substrates, with Installer present, for compliance with requirements for installation tolerances, moisture content, and other conditions affecting performance.

1. Verify that finishes of substrates comply with tolerances and other requirements specified in other Sections and that substrates are free of cracks, ridges, depressions, scale, and foreign deposits that might interfere with adhesion of resilient products.

2. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 PREPARATION

Extensive surface preparation is required over substrates from which existing products have been removed. Requirements vary among manufacturers. Insert requirements to suit Project.

A. Prepare substrates according to manufacturer's written recommendations to ensure adhesion of resilient products.

B. Concrete Substrates: Prepare according to ASTM F 710.

1. Verify that substrates are dry and free of curing compounds, sealers, and hardeners.

2. Alkalinity and Adhesion Testing: Perform tests recommended by manufacturer. Proceed with installation only after substrates pass testing.

3. Moisture Testing:

a. Perform anhydrous calcium chloride test, ASTM F 1869. Proceed with installation only after substrates have maximum moisture-vapor-emission rate of 3 lb of water/1000 sq. ft. (1.36 kg of water/92.9 sq. m) in 24 hours.

b. Perform tests recommended by manufacturer. Proceed with installation only after substrates pass testing.

C. Remove substrate coatings and other substances that are incompatible with adhesives and that contain soap, wax, oil, or silicone, using mechanical methods recommended by manufacturer. Do not use solvents.

D. Use trowelable leveling and patching compound to fill cracks, holes, and depressions in substrates.

E. Move resilient products and installation materials into spaces where they will be installed at least 48 hours in advance of installation.

1. Do not install resilient products until they are same temperature as space where they are to be installed.

F. Sweep and vacuum clean substrates to be covered by resilient products immediately before installation. After cleaning, examine substrates for moisture, alkaline salts, carbonation, and dust. Proceed with installation only after unsatisfactory conditions have been corrected.

3.3 TILE INSTALLATION

A. Lay out tiles from center marks established with principal walls, discounting minor offsets, so tiles at opposite edges of room are of equal width. Adjust as necessary to avoid using cut widths that equal less than one-half tile at perimeter.

1. Lay tiles in patterns indicated.

B. Match tiles for color and pattern by selecting tiles from cartons in the same sequence as manufactured and packaged, if so numbered. Discard broken, cracked, chipped, or deformed tiles.

1. Lay tiles in pattern of colors and sizes indicated.

If built-in items are required to be set on top of tile, indicate on Drawings and revise first paragraph below.

C. Scribe, cut, and fit tiles to butt neatly and tightly to vertical surfaces and permanent fixtures including built-in furniture, cabinets, pipes, outlets, edgings, door frames, thresholds, and nosings.

D. Extend tiles into toe spaces, door reveals, closets, and similar openings.

E. Maintain reference markers, holes, and openings that are in place or marked for future cutting by repeating on floor tiles as marked on substrates. Use chalk or other nonpermanent, nonstaining marking device.

Delete paragraph below if no covers.

F. Install tiles on covers for telephone and electrical ducts and similar items in finished floor areas. Maintain overall continuity of color and pattern with pieces of tile installed on covers. Tightly adhere tile edges to substrates that abut covers and to cover perimeters.

Revise below if other than full-spread adhesive method is recommended by tile manufacturer for substrate and tile products selected.

G. Adhere tiles to flooring substrates using a full spread of adhesive applied to substrate to produce a completed installation without open cracks, voids, raising and puckering at joints, telegraphing of adhesive spreader marks, and other surface imperfections.

3.4 RESILIENT WALL BASE INSTALLATION

A. Apply wall base to walls, columns, pilasters, casework and cabinets in toe spaces, and other permanent fixtures in rooms and areas where base is required.

B. Install wall base in lengths as long as practicable without gaps at seams and with tops of adjacent pieces aligned.

C. Tightly adhere wall base to substrate throughout length of each piece, with base in continuous contact with horizontal and vertical substrates.

D. Do not stretch wall base during installation.

Delete first paragraph below if not required or revise to suit Project.

E. On masonry surfaces or other similar irregular substrates, fill voids along top edge of wall base with manufacturer's recommended adhesive filler material.

F. Premolded Corners: Install premolded corners before installing straight pieces.

G. Job-Formed Corners:

1. Inside Corners: Use straight pieces of maximum lengths possible. Form by cutting an inverted V-shaped notch in toe of wall base at the point where corner is formed. Shave back of base where necessary to produce a snug fit to substrate.

3.5 CLEANING AND PROTECTION

A. Perform the following operations immediately after completing resilient product installation:

1. Remove adhesive and other blemishes from exposed surfaces.

2. Sweep and vacuum surfaces thoroughly.

3. Damp-mop surfaces to remove marks and soil.

a. Do not wash surfaces until after time period recommended by manufacturer.

B. Protect resilient products from mars, marks, indentations, and other damage from construction operations and placement of equipment and fixtures during remainder of construction period. Use protection methods recommended in writing by manufacturer.

Before retaining subparagraph and associated subparagraphs below, verify manufacturers' recommendations for products selected. Generally, polishes are not recommended for rubber products. Solid vinyl tile may be dry buffed.

1. Apply protective floor polish to horizontal surfaces that are free from soil, visible adhesive, and surface blemishes if recommended in writing by manufacturer.

a. Use commercially available product acceptable to manufacturer.

Revise subparagraph above and below to suit products selected.

b. Coordinate selection of floor polish with Government's maintenance service.

Delete application of floor polish in subparagraph and associated subparagraphs above or building paper in first subparagraph below, or both. Coordinate with manufacturers' written recommendations for products selected.

2. Cover products installed on horizontal surfaces with undyed, untreated building paper until Substantial Completion.

3. Do not move heavy and sharp objects directly over surfaces. Place hardboard or plywood panels over flooring and under objects while they are being moved. Slide or roll objects over panels without moving panels.

Final cleaning is normally not work of this Section. Specify final cleaning requirements in Division 1.

END OF SECTION 09651

Resilient Floor Tiles, Wall Base, and Accessories

09651-6