Ft Hamilton CDC A-504 20260610.pdf

PDF 247 KB Posted

Attached to
Construction of New Child Development Center, Fort Hamilton, NY
Solicitation number
W912DS26RA018
Issued by

About this file

This is an architectural drawing sheet containing wall detail specifications for a Child Development Center at USAG Fort Hamilton, New York. The document, prepared by the US Army Corps of Engineers New York District, provides four detailed wall construction sections at a 1" = 1'-0" scale, with one section shown at 1 1/2" = 1'-0" magnification.

The wall details specify construction standards for three distinct base conditions: CMU (concrete masonry unit) wall, stud wall, and slab depression configurations. Common elements across all sections include continuous air barriers, damp proofing, R-10 and R-15 rigid insulation specifications, 6" capillary barriers, SST metal flashing with weepholes at 24" on-center spacing, dovetail anchors at specified coursing intervals, and backer rod with sealant over 1/2" expansion joints. The stud wall detail specifies 6" cold-formed metal studs with minimum R-20 mineral wool batt insulation, 4" brick veneer with 2" minimum air gap, 5/8" gypsum wallboard, and polyiso continuous insulation with minimum R-12 rating. The slab depression detail includes a depressed concrete slab with gravel fill for mechanical yard areas and Pittsburgh seam flashing connections. All sections reference structural and civil drawings for footing and pavement specifications. The drawing is associated with Solicitation No. W912DS23F0031 and Contract No. W912DS19D0007, issued August 29, 2025, with Project No. 75662.

View the file

Other files

File Type Posted
FH - CDC - ELECTRICAL - SITE PLAN - LIGHTING_Amendment1-ES-102.pdf PDF
FH - CDC - ELECTRICAL - SITE PLAN - POWER_Amendment1-ES101.pdf PDF
Solicitation Amendment W912DS26RA0180003 SF 30.pdf PDF
31 00 00_YQA_LEWA_17-JUL-26.docx DOCX document
2026-07-09-FH-CDC RFI DRAWINGS-IN.pdf PDF
Attachment 3 - revised and reissued - updated 14Jul26.pdf PDF
Spec Sect 00 22 10 - Selection Procedure and Basis of Award - Revised and Reissued 16Jul26.pdf PDF
Ft Hamilton CDC T-505 20260708.pdf PDF
Amendment 0002 - SCDC Ft Hamilton - Plans.pdf PDF
Solicitation Amendment W912DS26RA0180002 SF 30.pdf PDF
IN101 from 7-FH-CDC-INTERIORS-UPDATED RTA-DRAW.pdf PDF
VOL 1 of 3 - 75662-FH-CDC CORRECTED RTA DRAWINGS 13 NOV 25.pdf PDF
VOL 3 of 3 - 75662-FH-CDC CORRECTED RTA DRAWINGS 13 NOV 25.pdf PDF
Solicitation Amendment W912DS26RA0180001 SF 30.pdf PDF
Solicitation Amendment - W912DS26RA0180001 Professional Appearance.pdf PDF
Daily Waiver.pdf PDF
VOL 2 of 3 - 75662-FH-CDC CORRECTED RTA DRAWINGS 13 NOV 25.pdf PDF
075662-FH-CDC CORRECTED RTA DRAWINGS 13 NOV 25 part 2.pdf PDF
075662-FH-CDC CORRECTED RTA DRAWINGS 13 NOV 25 part 1.pdf PDF
075662-FH-CDC CORRECTED RTA DRAWINGS 13 NOV 25 part 3.pdf PDF
075662-FH-CDC DRAWINGS 25 MARCH 26.pdf PDF
Solicitation - W912DS26RA018 Professional Appearance.pdf PDF
Attachment 3 - Fort Hamilton CDC-5.pdf PDF
Appendix A - Fort Hamilton CDC-2.pdf PDF
075662-FH-CDC-CORRECTED RTA SPECS.pdf PDF
Attachment 1 - Fort Hamilton CDC-5.pdf PDF
Appendix G - Fort Hamilton CDC-4.pdf PDF
Appendix F- Fort Hamilton CDC-3.pdf PDF
Attachment 2 - Fort Hamilton CDC-5.pdf PDF
Attachment 4 - Fort Hamilton CDC-5.pdf PDF
Attachment 5 - Fort Hamilton CDC-5.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR

0' - 0"

C

BACKER ROD AND SEALANT

OVER 1/2" EXPANSION JOINT

R-15 RIGID INSULATION FOR 24"

4" CONCRETE SLAB

(SEE STRUCT DWGS)

DAMP PROOFING

CONTINUOUS AIR BARRIER

EXTERIOR

C.1

CONCRETE PAVEMENT

(SEE CIVIL DWGS)

GROUT INFILL

WEEPHOLE @ 24" O.C.

SST METAL FLASHING

(EXTEND 6" MIN ABOVE

MORTER NET)

MORTAR NET

WITH INSECT BARRIER

DOVE TAIL ANCHORS

@ EVERY 2 BLOCK COURSING

INTERIOR

CONCRETE FOOTING

(SEE STRUCT DWGS)

2' - 0"

BACKER ROD AND

SEALANT OVER

1/2" EXPANSION JOINT

6" CAPILLARY BARRIER

R-10 RIGID INSULATION

EXT WALL TYP

DRIP EDGE

(MIN 8" ABOVE GROUND)

T Y

P

M

IN

FIRST FLOOR

0' - 0"

INTERIOR

BACKER ROD AND SEALANT

OVER 1/2" EXPANSION JOINT

4" CONCRETE

SLAB-ON-GRADE

(SEE STRUCT DWGS)

CONTINUOUS AIR

BARRIER

EXTERIOR

R-15 RIGID INSULATION

FOR 24"

6" CAPILLARY BARRIER

R-10 RIGID INSULATION

CONCRETE FOOTING

(SEE STRUCT DWGS)

6" COLD FORMED METAL STUDS/

MIN R-20 MINERAL WOOL

BATT INSULATION IN CAVITY

MORTAR NET

WITH INSECT BARRIER

DOVETAIL ANCHOR @

EVERY 6 BRICK COURSING

SST METAL FLASHING

(EXTEND 6" MIN ABOVE

MORTER NET)

WEEPHOLE @ 24" O.C.

GROUT INFILL

5/8" GYP WALLBOARD

DAMP PROOFING

CONCRETE PAVEMENT

(SEE CIVIL DWGS)

BACKER ROD AND SEALANT

OVER 1/2" EXPANSION JOINT

DRIP EDGE

(MIN 8" ABOVE GROUND)

R-12 RIGID INSULATION

4" BRICK VENEER

T Y

P

M

IN

T Y

P

AIR GAP (2" MIN)

FIRST FLOOR

0' - 0"

CC.1

BACKER ROD AND SEALANT OVER

1/2" EXPANSION JOINT

R-15 RIGID INSULATION FOR 24"

6" CAPILLARY BARRIER

4" DEPRESSED

CONCRETE SLAB

(SEE STRUCT DWGS)

GRAVEL (MECH YARD)

(SEE CIVIL DWGS)

GROUT INFILL

DRIP EDGE

(MIN 8" ABOVE GROUND)

SST METAL FLASHING

(EXTEND 6" MIN ABOVE

MORTER NET)

MORTAR NET

WITH INSECT BARRIER

DOVE TAIL ANCHORS

@ EVERY 2 BLOCK COURSING

CONCRETE FOOTING

(SEE STRUCT DWGS)

CONTINUOUS AIR BARRIER

DAMP PROOFING

WEEPHOLE @ 24" O.C.

EXT WALL TYP

R-10 RIGID INSULATION

SELF ADHERED FLASHING

COVER

PITTSBURGH SEAM FLASHING

CONNECTION FOR ADHERED

FOUNDATION INSULATION AND

THROUGH WALL INSULATION

3 5/8" METAL STUD

5/8" GYP WALLBOARD

4" NOMINAL

BRICK VENEER

AIR GAP 2" MIN

POLYISO

CONTINUOUS INSULATION

MIN R-12

1'-8 1/2" TYP

MIN

0' - 2"

CONTINUOUS

AIR BARRIER

8" CMU BLOCK

DOVE TAIL ANCHOR

@ EVERY 2 BLOCK

COURSING

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P L O

T D

A T

E

F

IL

E L

O C

A T

IO

N

/1 /2

:2

:5

A M

R d m s

\F

H -C

D C

-D M

M -A

.r v t

A-504

W A

L L D

E T

A

IL

S

C H

IL

D

D E

V E

L O

P M

E N

T C

E N

T E

R N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

J K

IM

J K

IM

C h e c k e r

A U

G U

S T

W D

S F

W D

S D

U S

A G

F O

R T

H A

M

IL

T O

N N

E W

Y O

R K

P R

O J E

C T

N O

1" = 1'-0"

WALL BASE DETAIL AT CMU WALL TYP

1" = 1'-0"

WALL BASE DETAIL AT STUD WALL

1" = 1'-0"

WALL BASE DETAIL AT SLAB DEPRESSION

1'6" 2'0

SCALE: 1" = 1'-0"

1 1/2" = 1'-0"

TYPICAL EXTERIOR WALL (EXT WALL TYP)

2'0 1'6"

SCALE: 1 1/2" = 1'-0"

Sheets
A-504 - WALL DETAILS

File details come from the government source that posted it. Updated .