075662-FH-CDC CORRECTED RTA DRAWINGS 13 NOV 25 part 1.pdf
PDF 27 MB Posted
- Solicitation number
- W912DS26RA018
About this file
This file contains corrected architectural and life safety drawings for the Child Development Center (CDC) facility at Fort Hamilton, NY. The drawings depict the facility's floor plan layout, including room designations, occupancy capacities, and fire safety requirements. The facility spans 16,632 square feet and accommodates children ages 6 weeks to 5 years across multiple activity rooms for different age groups (infant/pre-toddler, preschool/pre-K, and outreach/transitional care). The plan specifies 13 activity rooms with occupancies ranging from 19 to 34 persons, along with supporting spaces including a kitchen (914 SF, 10 occupants), staff lounge (284 SF, 10 occupants), mechanical room (756 SF, 2 occupants), laundry, administrative offices, and various storage and sanitary areas.
The drawings illustrate comprehensive life safety infrastructure compliant with UFC 4-740-14 Section 7-2.3.3 and NFPA 16.3.2 standards. Multiple exit doors are positioned throughout the facility with travel distances not exceeding 100 feet maximum, and the minimum distance between exits is 84 feet 6.25 inches (exceeding the 76-foot minimum requirement). Fire protection features include Type ABC and Type K fire extinguishers strategically located. The floor plan also indicates mechanical systems with tiered air handling units (18x30, 18x36, 18x42, 24x36, 24x54, and 24x60 configurations) for heating and air conditioning, panic hardware on main corridor doors, and electrical and communications equipment rooms. Three outdoor play areas totaling 16,667 square feet are identified (Playgrounds A, B, and C), designed to accommodate age-appropriate equipment and safety surfacing for the center's occupants.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
126 122
002C
111 115 132 130
122B
004A
002B
005B
005A
105B
109B
003A
132B
115B
111B
126B
130B
118 114
118B
AS PER UFC
4-740-14 SECTION
7-2.3.3
NFPA 16.3.2.2
AS PER NFPA 16.3.2.1
NOTE: PANIC HARDWARE WILL BE PROVIDED
ON MAIN CORRIDOR DOORS
23-T
12 23-T
RRD
AIR
OUT
AIR
IN
RRD
AIR
OUT
AIR
IN
18x304 TIER
18x304 TIER x
T
IE
R
A
IR
IN
24x604 TIER
24x604 TIER
C
C H x3
T
IE
R x
T
IE
R x
T
IE
R x
T
IE
R x
T
IE
R x
T
IE
R x
T
IE
R
S S
E1
H
C
D D
D
DC
D
H
H
C
24x604 TIER
24x544 TIER 24x364 TIER
C W O
C W
IC
W O
C W I
1070 SF
OCC:31
PRESCHOOL/PRE-K ACTIVITY RM 03
126 1071 SF
OCC:31
OUTREACH/TRANSITIONAL CARE
ACTIVITY RM
247 SF
OCC:13
TRAINING RM
660 SF
OCC:19
INFANT/PRE-TODDLER ACTIVITY RM
46 SF
OCC:1
JANITOR
CLOSET
631 SF
OCC:19
INFANT/PRE-TODDLER ACTIVITY RM
652 SF
OCC:19
INFANT/PRE-TODDLER ACTIVITY RM
1079 SF
OCC:31
PRESCHOOL/PRE-K ACTIVITY RM 02
92 SF
OCC:1
CENTRAL STORAGE
59 SF
OCC:1
STORAGE
122B
42 SF
OCC:1
EXT STORAGE
1078 SF
OCC:31
PRESCHOOL/PRE-K ACTIVITY RM 01
30 SF
OCC:1
STORAGE
004A
47 SF
OCC:1
PUBLIC TOILET
002B
42 SF
OCC:1
ISO
TOILET
005B
106 SF
OCC:1
WAITING
AREA
146 SF
OCC:1
OPEN
OFFICE
AREA
55 SF
OCC:1
ISOLATION
AREA
005A
46 SF
OCC:1
STORAGE
105B
49 SF
OCC:1
STORAGE
109B
49 SF
OCC:1
EXT STORAGE
91 SF
OCC:1
RECEPTION
59 SF
OCC:1
CCTV
EQUIPMENT
53 SF
OCC:1
STORAGE
132B
42 SF
OCC:1
EXT STORAGE
48 SF
OCC:1
TOILET 01
46 SF
OCC:1
STORAGE
115B
54 SF
OCC:1
STORAGE
111B
42 SF
OCC:1
EXT STORAGE
41 SF
OCC:1
EXT STORAGE
51 SF
OCC:1
STORAGE
126B
44 SF
OCC:1
STORAGE
130B
51 SF
OCC:1
TOILET 02
84 SF
OCC:1
VESTIBULE
284 SF
OCC:10
STAFF LOUNGE
48 SF
OCC:1
NURSING MOTHERS RM
38 SF
OCC:1
STROLLER/
CAR SEAT
STORAGE
002C
914 SF
OCC:10
KITCHEN
1162 SF
OCC:34
ACTIVE PLAYROOM
756 SF
OCC:2
MECHANICAL
97 SF
OCC:1
LAUNDRY
DIAGONAL DISTANCE ACROSS FLOOR AREA 228' - 2 1/4"
116 SF
OCC:1
COMMUNICATIONS
88 SF
OCC:1
ASSISTANT
DIRECTORS
OFFICE
139 SF
OCC:1
DIRECTORS
OFFICE
WHITE AVE
1823 SF
OCC:13
CORRIDOR
DISTANCE BETWEEN EXITS 84' - 6 1/4" (MIN. 76'-0" REQ'D)
17034"
EXIT DOOR
42664"
EXIT DOOR
WHITE AVE
17034"
EXIT DOOR
17034"
EXIT DOOR
CP
: 2
3'-
MA
X:
0'- 0"
17034"
EXIT DOOR
1161616
17034"
EXIT DOOR
17034"
EXIT DOOR
17034"
EXIT DOOR
17034"
EXIT DOOR
17034"
EXIT DOOR
17034"
EXIT DOOR
17034"
EXIT DOOR
C.P.T.
16'-8"
161010
10 10
17034"
EXIT DOOR
42664"
EXIT DOOR
17034"
EXIT DOOR
EXIT TO
PUBLIC WAY
EXIT TO
PUBLIC WAY
EXIT TO
PUBLIC WAY
EXIT TO
PUBLIC WAY
EXIT TO
PUBLIC WAY
EXIT TO
PUBLIC WAY
MECHANICAL YARD
EXIT TO
PUBLIC WAY
EXIT TO
PUBLIC WAY
EXIT TO
PUBLIC WAY
FE- A FE- A
FE
-A
FE-
ABC FIRE
EXTINGUISHER
TYPE K FIRE
EXTINGUISHER
FE-
TY
P.
T
RA
VE
L D
IS
TA
NC
E:
'-0
CP
: 1
4'- 0"
MA
X:
0'-
0"
5965 SF
Playground B P-02
7548 SF
Playground C P-03
3658 SF
Playground A (Infant) P-01
CP: 22'-00"
MAX: 100'-0"
CP: 17'-0"
MAX: 100'-0"
60 SF
OCC:1
STORAGE
118B
113 SF
OCC:1
ELECTRICAL
18 32 SF
OCC:1
RECYCLE RM
CP: 34'-00"
MAX: 100'-0"
CP: 17'-00"
MAX: 100'-0"
CP: 13'-06"
MAX: 100'-0"
CP: 37'-06"
MAX: 100'-0"
CP
: 1
7'-
MA
X:
0'- 0"
CP: 15'-00"
MAX: 100'-0"
CP
: 1
7'-
MA
X:
0'- 0"
CP
: 1
6'-
MA
X:
0'- 0"
CP
: 1
1'-
MA
X:
0'- 0"
CP: 14'-10"
MAX: 100'-0"
BUSINESS (GROUP B)
BUSINESS COLLABORATION <450SF (GROUP A)
DAYCARE (GROUP I-4)
KITCHEN
MECHANICAL & EQUIP USE
STORAGE
664 SF
OCC:19
INFANT/PRE-TODDLER ACTIVITY RM
FE- AFE- A
10'-0"
IM
AG
IN
AR
Y
'-0 " L
OT
LI
NE
IM
AG
IN
AR
Y
'-0 " L
OT
LI
NE
10'-0"
6' - 5 1/2"
MAIN ENTRANCE
FIRE DEPT ACCESS
FH
APPROX. 175'-0"
FH
SEE CIVIL DWGS FOR
ACCURATE LOCATION
FA
A
FMCU
AED
LO
C
NO FIRE RATING
1 HR FIRE RATING
LEGEND
00032"
EXIT DOOR
EGRESS CAPACITY
# OF OCCUPANTS EXITING
DOOR CLEAR WIDTH
DOOR CLEAR WIDTH
0 EXIT TAG
(# OF OCCUPANTS EXITING)
FE- X FIRE EXTINGUISHER IN CABINET
A - WATER
B - DRY CHEMICAL
C - GASEOUS
EXIT TO PUBLIC WAY
COMMON PATH OF TRAVEL (CP)
2-WAY OPTIONAL DIRECTION OF TRAVEL
FE- FIRE EXTINGUISHER
BUILDING EXIT
SMOKE PARTITIONS
AED FULLY RECESSED IN CABINETAED
OCCUPANT LOAD TABLE
OCCUPANCY USE OCCUPANT
LOAD FACTOR
BUSINESS
BUSINESS
COLLABORATION<450 SF
DAYCARE
KITCHEN
MECHANICAL &
EQUIP USE
STORAGE
1 PERSON / 150 GROSS
1 PERSON/ 15 SF NET
1 PERSON/ 35 SF NET
1 PERSON / 100 SF NET
1 PERSON/ 500 SF GROSS
1 PERSON / 500 SF GROSS
NFPA 101 TABLE 7.3.1.2
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
PL
O
T D
AT
E:
FI
LE
L O
C
AT
IO
N
/2 3/
2:
:1
PM
R :\d m s2
7 8
\F H
-C D
C -D
M M
-A .rv t
GI101
LI
FE
S
AF
ET
Y
PL
AN
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R N
EW
Y
O R
K D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
JK JK C
he ck er
AU
G
U
ST
9, W
2D S2
3F
W
2D S1
9D
U
SA
G F
O R
T H
AM
IL
TO
N
, N
EW
Y O
R K
PR
O
JE
C
T N
O . 7
3/32" = 1'-0"1 LIFE SAFETY PLAN
PLAN NORTH
16'8' 32'0
SCALE: 3/32" = 1'-0"
OCCUPANCY CLASS (IBC, NFPA)
L-001
LA
N
D
SC
AP
E
N O
TE
S
PL
AN
T
SC
H
ED
U
LE
GENERAL LANDSCAPE NOTES: PLANTING NOTES:
1. THE LOCATION OF ALL TREES, SHRUBS, AND GROUNDCOVER AREAS SHOWN ON THE PLAN
SHALL BE STAKED/FLAGGED BY THE CONTRACTOR AND APPROVED BY THE GOVERNMENT
BEFORE THE DIGGING OF PITS. PLANTING SHALL BE LOCATED WHERE SHOWN ON THE
DRAWINGS OR WHERE FIELD LOCATED BY OWNER.
2. PROVIDE ONLY PLANTS THAT ARE FREE FROM DISEASES AND PESTS, AND THAT COMPLY WITH THE LATEST EDITION OF PUBLICATION ANSI Z60.1, AMERICAN STANDARDS FOR NURSERY STOCK, BY THE AMERICAN ASSOCIATION OF NURSERYMEN.
3. DO NOT MAKE SUBSTITUTIONS REGARDING PLANT SIZES OR SPECIES WITHOUT WRITTEN
PERMISSION FROM THE GOVERNMENT.
4. REMOVE ALL STRINGS AND OTHER TIES FROM TREES.
5. FERTILIZE ALL PLANTS WITH 16-16-16 SLOW RELEASE FERTILIZER AT THE RATE OF: 3 LBS PER
CUBIC YARD OF SOIL MIX; 3 LBS PER 100 SF OF BED FOR SHRUBS AND GROUNDCOVER.
6. BALLED AND BURLAPPED OR "B&B" PLANTS SHALL BE DUG WITH FIRM, NATURAL BALLS OF
EARTH OF SUFFICIENT DIAMETER AND DEPTH TO ENCOMPASS THE FIBROUS AND FEEDING
ROOT SYSTEM NECESSARY FOR FULL RECOVERY OF THE PLANT. BALLS SHALL BE FIRMLY
WRAPPED WITH BURLAP OR SIMILAR MATERIAL AND BOUND WITH TWINE OR CORD.
7. AT A MINIMUM THE TOP ONE-HALF OF THE ROOT BALL IS TO HAVE ALL BURLAP AND TWINE
REMOVED. IF ROOTS ARE GIRDLING OR CIRCLING THEY MUST BE LOOSENED OR CUT.
8. THE BALLS OF "B&B" PLANTS WHICH CANNOT BE PLANTED IMMEDIATELY ON DELIVERY SHALL BE
COVERED WITH MOIST SOIL OR MULCH, OR OTHER PROTECTION FROM DRYING WINDS AND SUN.
ALL PLANTS INSTALLED OR STORED SHALL BE WATERED BY CONTRACTOR AS NECESSARY
UNTIL FINAL ACCEPTANCE.
9. ALL PLANTS SHALL BE HANDLED SO THAT ROOTS ARE ADEQUATELY PROTECTED AT ALL TIMES.
DURING SHIPMENT, THE ENTIRE PLANT SHALL BE PROTECTED BY TARPAULINS OR OTHER
SUITABLE COVERING. PLANT MATERIAL SUFFERING FROM WIND BURN OR OTHER DAMAGE IS
NOT ACCEPTABLE.
10. NO PLANT SHALL BE BOUND WITH ROPE OR WIRE IN A MANNER THAT DAMAGES THE BARK,
BREAKS BRANCHES, OR DESTROYS ITS NATURAL SHAPE. NO PLANT MATERIAL REQUIRED TO BE
BALLED AND BURLAPPED SHALL BE ACCEPTED IF THE BALL IS CRACKED OR BROKEN EITHER
BEFORE OR DURING THE PROCESS OF PLANTING, OR WHEN REQUIRED BURLAP, STAVES, ROPES
OR PLATFORM HAVE BEEN REMOVED.
11. ANY SERIES OF TREES OR SHRUBS TO BE PLACED IN A PARTICULAR ARRANGEMENT WILL BE
FIELD CHECKED FOR ACCURACY BY THE GOVERNMENT. ANY PLANTS INCORRECTLY ARRANGED
SHALL BE RELOCATED WITH GOVERNMENT APPROVAL.
12. PRE-EMERGENT HERBICIDE SHALL BE APPLIED (ACCORDING TO MANUFACTURER'S
INSTRUCTIONS) TO ALL PLANT BEDS, PRIOR TO PLANTING, FOR NOXIOUS WEED CONTROL.
AVOID OVER APPLICATION INTO SEEDED/SODDED GRASS AREAS.
13. ALL PLANTING BEDS AND TREE PLANTINGS SHALL RECEIVE A MINIMUM 3" DEEP SHREDDED
HARDWOOD MULCH LAYER.
14. CONTRACTOR IS RESPONSIBLE FOR THE WATERING AND MAINTENANCE OF ALL INSTALLED
PLANT MATERIAL, INCLUDING GRASS, UNTIL FINAL ACCEPTANCE BY GOVERNMENT. WATER ALL
PLANT MATERIAL AT TIME OF PLANTING.
15. ALL PLANT MATERIAL IS TO BE GUARANTEED FOR ONE (1) YEAR. GUARANTEE PERIOD STARTS
FROM DATE OF SUBSTANTIAL COMPLETION.
16. GROUNDCOVER SPACING PATTERN SHALL BE AS INDICATED ON TYPICAL SPACING PATTERN
USING SPACING DIMENSION AS SHOWN ON PLANS AND SCHEDULE.
17. ALL PLANTING AREAS ARE TO HAVE SOIL TESTS PERFORMED UPON THEM TO DETERMINE IF THE
PROPER SOIL PH IS PRESENT. RESULTS FROM THESE TESTS ARE TO BE SENT TO THE
GOVERNMENT. IF THE TEST INDICATES MPROPER PH, THEN THE LANDSCAPE CONTRACTOR IS
TO ADD LIME OR SULFUR TO PROVIDE THE PROPER SOIL PH.
18. LANDSCAPE CONTRACTOR SHALL SUBMIT TYPEWRITTEN INSTRUCTIONS RECOMMENDING
PROCEDURES TO BE ESTABLISHED BY GOVERNMENT FOR MAINTENANCE AND WATERING OF
LANDSCAPE WORK FOR ONE FULL YEAR. SUBMIT PRIOR TO FINAL ACCEPTANCE.
19. THE GOVERNMENT MAY INSPECT TREES AND SHRUBS EITHER AT NURSERY OR ON-SITE PRIOR
TO PLANTING, FOR COMPLIANCE WITH REQUIREMENTS FOR GENUS, SPECIES, SIZE, AND
QUALITY. THE GOVERNMENT RETAINS THE RIGHT TO FURTHER INSPECT TREES AND SHRUBS
FOR SIZE AND CONDITION OR ROOT BALL, INSECTS, INJURIES, AND LATENT DEFECTS TO REJECT
UNSATISFACTORY OR DEFECTIVE PLANT MATERIAL AT ANY TIME DURING PROGRESS OF WORK.
REMOVE REJECTED MATERIAL IMMEDIATELY FROM THE PROJECT SITE.
20. REPLACEMENTS SHALL CLOSELY MATCH ADJACENT SPECIMENS OF THE SAME SPECIES AND
SHALL CONFORM TO THE STANDARDS FOR PLANT MATERIALS SPECIFIED. ALL REPLACED
MATERIAL SHALL IMMEDIATELY BE REMOVED FROM THE SITE AND ALL NECESSARY REPAIRS TO
GRADES, LAWN AREAS, PAVING, AND OTHER AREAS DAMAGED DURING REPLACEMENT SHALL BE
MADE AT NO COST TO THE GOVERNMENT.
21. ONLY ONE REPLACEMENT PER TREE, SHRUB, OR PLANT WILL BE REQUIRED AT THE END OF THE
WARRANTY, EXCEPT FOR LOSSES OR REPLACEMENTS DUE TO FAILURE TO COMPLY WITH THE
REQUIREMENTS.
SODDING NOTES:
1. REFER TO CIVIL DRAWINGS AND SPECIFICATIONS FOR SODDING. SOD SHOULD BE USED AS
APPROPRIATE UNLESS SPECIFICALLY NOTED OTHERWISE.
2. REPAIR WITH SOD, AS APPROPRIATE, ALL ERODED OR DISTURBED AREAS WHERE VEGETATIVE
COVER HAS NOT BEEN ESTABLISHED.
3. CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF SODDED AREAS UNTIL AREAS EXHIBIT
HEALTHY AND VIGOROUS GROWTH AS DETERMINED BY THE GOVERNMENT.
1. UNDERGROUND UTILITIES EXIST ON SITE. THE LOCATION OF ALL SURFACE AND UNDERGROUND UTILITIES, RIGHT-OF-WAYS, EASEMENTS, ETC., SHALL BE VERIFIED BY THE CONTRACTOR AND
THE GOVERNMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL UTILITIES
FROM DAMAGE DURING CONSTRUCTION AND TO REPAIR ANY DAMAGE WHICH SHOULD OCCUR
TO THE SATISFACTION OF THE GOVERNMENT. COMMENCEMENT OF LANDSCAPE INSTALLATION
INDICATES ACCEPTANCE BY THE GOVERNMENT OF EXISTING CONDITIONS.
2. EXAMINE SUBGRADE UPON WHICH WORK IS TO BE PERFORMED. VERIFY SUBGRADE ELEVATIONS, OBSERVE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED, AND PROVIDE PERCOLATION
TESTS AND ALL OTHER TESTS NECESSARY TO ASCERTAIN THAT ADEQUATE GROWING
CONDITIONS WILL BE PROVIDED FOR PLANTS. IF PERCOLATION TESTS OR SUBSOIL CONDITIONS
INDICATE RETENTION OF WATER IN PLANTING AREAS, AS SHOWN BY SEEPAGE OR OTHER
EVIDENCE INDICATING PRESENCE OF UNDERGROUND WATER, NOTIFY GOVERNMENT IN WRITING
OF THIS FACT OR OTHER UNSATISFACTORY CONDITIONS BEFORE BACKFILLING. A CHANGE
ORDER MAY BE ISSUED TO DIRECT INSTALLATION OF DRAIN TILE OR OTHER MEASURES BEYOND
DRAINAGE REQUIREMENTS INDICATED. DO NOT PROCEED WITH THE WORK UNTIL
UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. COMMENCEMENT OF PLANTING WORK
INDICATES THAT SITE CONDITIONS HAVE BEEN ACCEPTED "AS IS" BY THE GOVERNMENT.
3. AS-BUILT SITE CONDITIONS MAY VARY FROM THIS PLAN. PLANT AND MATERIAL QUANTITIES AS
SHOWN ON THE PLAN ARE FOR UNIFORM COMPARISON AND ESTIMATE PURPOSES ONLY. NOTIFY
GOVERNMENT OF ALL SITE CONDITIONS WHICH WILL AFFECT PLANT QUANTITIES REQUIRED
AND/OR THEIR LOCATIONS.
4. PROTECT EXISTING GRASS AREAS, TREES, AND OTHER VEGETATION TO REMAIN.
5. DAMAGE BY CONTRACTOR TO UNDISTURBED AREAS OUTSIDE THE LIMITS OF CONSTRUCTION
SHALL BE REPAIRED BY CONTRACTOR TO THE SATISFACTION OF THE GOVERNMENT.
6. THE QUANTITIES INDICATED ON THE DRAWINGS ARE PROVIDED FOR THE BENEFIT OF THE
CONTRACTOR, BUT SHOULD NOT BE ASSUMED TO ALWAYS BE CORRECT. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR HIS OWN QUANTITY CALCULATIONS AND THE LIABILITY WHICH
PERTAINS TO THOSE QUANTITIES AND ANY RELATED CONTRACT DOCUMENTS AND/OR PRICE
QUOTATIONS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING PLANT QUANTITIES REQUIRED TO
COVER SPECIFIED AREAS AT THE DESIGNATED SPACING.
7. CONTRACTOR IS RESPONSIBLE FOR CONDUCTING SITE INSPECTION PRIOR TO BIDDING WORK, TO DETERMINE SITE CONDITIONS AND AREAS TO BE PLANTED. SUBMISSION OF BID INDICATES
CONTRACTOR HAS VERIFIED SITE CONDITIONS AND PLANT MATERIAL QUANTITIES.
8. INSPECTION: GOVERNMENT REPRESENTATIVE OR LANDSCAPE ARCHITECT MUST BE PRESENT
WHEN TREES ARE INSTALLED.
9. SUBSTANTIAL COMPLETION: WILL BE PROVIDED AFTER THE CONTRACTOR HAS SATISFACTORILY
COMPLETED WORK REQUIREMENTS AS SPECIFIED. THE GOVERNMENT WILL CONDUCT A
SUBSTANTIAL COMPLETION INSPECTION AND PROVIDE A PUNCH LIST OF OBSERVED
DEFICIENCIES.
10. FINAL ACCEPTANCE: THE GOVERNMENT WILL PROVIDE THE FINAL INSPECTION AFTER THE
CONTRACTOR HAS SATISFACTORILY CORRECTED THE DEFICIENCIES ON THE PUNCH LIST.
SHOULD THE GOVERNMENT INSPECTION FIND WORK INCOMPLETE, THE CONTRACTOR SHALL
REMEDY THE DEFICIENCIES.
11. AFTER FINAL ACCEPTANCE AND PRIOR TO END OF WARRANTY PERIOD, CONTRACTOR SHALL
REPLACE ALL PLANT MATERIAL THAT HAS DIED OR HAS DEFECTS, INCLUDING UNSATISFACTORY
GROWTH, IN THE OPINION OF THE GOVERNMENT.
12. DURING LANDSCAPE INSTALLATION KEEP PAVEMENTS CLEAN AND WORK AREA IN ORDERLY
CONDITION.
13. CONTRACTOR TO REPAIR ANY PAVEMENTS, CURBS, AND OTHER IMPROVEMENTS DAMAGED AS A
RESULT OF LANDSCAPE INSTALLATION ACTIVITIES.
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R U
SA
G
F O
R T
H
AM
IL
TO
N , N
EW
Y
O R
K
Pr oj ec t N o.
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, N
EW
Y
O R
K, N
Y
US Army Corps of Engineers • •
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
AU
G
U
ST
9, W
2D S2
3F
W
2D
9D
8/
/2
3:
:0
PM
P:
\1
\1
-0
\3
- P
LA
N
N
IN
G
G
IS
\0 8_
W O
R
KI
N G
F
IL
ES
\A
U
TO
C
AD
\1
S
U
BM
IS
SI
O N
A.
B
LO
XD
O R
F
A.
B
LO
XD
O R
F
D . F
LY
N
N
A.
S
TA
R
R
US Army Corps of Engineers • •
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
SP
1" = 15'-0"
LANDSCAPE PLAN
3'Wx12'LX4'H
RAISED CONCRETE
PLANTER BOX
UP
AG
AG
CK
AG
UP
AG
PS
PS
PS
PS
L-101
LA
N
D
SC
AP
E
PL
AN
DECIDUOUS TREE
NOTES:
LEGEND:
1. SEE PLAYGROUND DRAWINGS FOR LAYOUT.
2. REFER TO CIVIL DRAWINGS FOR SITE LAYOUT
AND HARDSCAPE.
NOTES:
J1 L501
CONIFEROUS TREEJ9
L501
SHRUBE1
L501
GROUNDCOVERA1
L501
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R A.
B
LO
XD
O
R F
A.
B
LO
XD
O R
F U
SA
G
F O
R T
H
AM
IL
TO
N , N
EW
Y
O R
K
Pr oj ec t N o.
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, N
EW
Y
O R
K, N
Y
SODE9
L501
BOLLARD (OPTIONAL)D15
L501
GRAPHIC SCALE
15'015'
SCALE: 1" = 15'
30'
CANOPY DRIP TRENCHJ15
L501
B1
CANOPY DRIP TRENCH
WITH RIVER ROCK
AND MOW STRIP
RE: J15/L-501
AU
G
U
ST
9, W
2D S2
3F
W
2D
9D
D
. F
LY
N N
A.
S
TA
R
R
UP
AG
JC
AG
JC
JC
AG
AG
AG
PT
PS
PS
PS
PT
PS
PT
65 BOLLARDS
RE: D15/L-501
20 BOLLARDS
RE: D15/L-501
ENTRY
SIGN
8/
/2
3:
:0
PM
P:
\1
\1
-0
\3
- P
LA
N
N
IN
G
G
IS
\0 8_
W O
R
KI
N G
F
IL
ES
\A
U
TO
C
AD
\1
S
U
BM
IS
SI
O N
FIRE
HYDRANT
L-501
LA
N
D
SC
AP
E
D
ET
AI
LS
ROOT BALL
DIA. (X)
X X
3" DOUBLE SHREDDED
HARDWOOD MULCH.
DO NOT PLACE AGAINST
SHRUB
6" DEEP SOIL SAUCER
FOR WATERING
FINISHED LAWN GRADE 1/3 H COMPACTED TOPSOIL
1/3 H COMPACTED 50%
TOPSOIL AND 50% SUBSOIL
MIX
1/3 H COMPACTED 100%
SUBSOIL
SET ROOT BALL ON
UNDISTURBED SOIL SO THAT
THE ROOT COLLAR IS 3" ABOVE
FINISHED GRADE
PROVIDE NON-WOVEN
GEOTEXTILE WEED BARRIER
IN ALL LANDSCAPE BEDS
UNDISTURBED
SOIL
H
TILL SOIL TO A DEPTH OF 8"
ADDING SIX (6) CUBIC
YARDS OF LEAFMOLD PER
1000 SF OF BED AREA
REMOVE PLASTIC
CONTAINERS AND CUT
ROOT MASS VERTICALLY AT
4" INTERVALS ON LOWER
HALF3" SHREDDED
HARDWOOD
MULCH
PLANT
SPACING
24" O.C. MIN.
TYP.
ROOT BALL
DIA. (X)
XX
3" DOUBLE SHREDDED
HARDWOOD MULCH. DO NOT
PLACE AGAINST TRUNK OF TREE
6" DEEP SOIL SAUCER FOR
WATERING
FINISHED LAWN GRADE
1/3 H COMPACTED
TOPSOIL
1/3 H COMPACTED 50%
TOPSOIL AND 50% SUBSOIL
MIX
1/3 H COMPACTED 100%
SUBSOIL
PROVIDE NON-WOVEN
GEO-TEXTILE WEED BARRIER IN
ALL LANDSCAPE BEDS
DOUBLE STRAND TWISTED
MALLEABLE #10 GAGE
ANNEALED STEEL WIRE
(TWO OR THREE REQUIRED)
TWO (2) PIECES OF NEW
REINFORCED RUBBER HOSE
SUPPORT STAKE,
2'-0" MIN. EMBEDMENT
TWO (2) OR THREE (3) 2"x2"
OAK STAKES. NOTCH
STAKES TO HOLD WIRE
NTS
SHRUB
NTS
REMOVE DEAD OR
ELONGATED BRANCHES TO
MAINTAIN OVERALL SHAPE
SET ROOT BALL ON UNDISTURBED
SOIL SO THAT THE ROOT COLLAR
IS 3" ABOVE FINISHED GRADE
UNDISTURBED
SOIL
DECIDUOUS TREE
R O
W
SP
AC
IN
G
US Army Corps of Engineers • •
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R U
SA
G
F O
R T
H
AM
IL
TO
N , N
EW
Y
O R
K
Pr oj ec t N o.
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, N
EW
Y
O R
K, N
Y
R=PLANT ROW
P=PLANT SPACING
PLANT CENTER, TYP.
PLANT ROWS
STAGGERED
4"
SOD
AMENDED
TOPSOIL
COMPACTED
SUBGRADE
1/ 2"
CONDITIONS MAY VARY
EDGING STEEL
NOTES:
1. REMOVE ALL CORD FROM AROUND TRUNK AND REMOVE ALL METAL, PLASTIC, OR BURLAP
FROM TOP 1/3 OF ROOTBALL.
2. ALL PLANTS SHALL BE PLANTED TO BEAR THE SAME RELATION TO FINISHED GRADE AS IT BORE
TO PREVIOUS EXISTING GRADE AT NURSERY.
BACKFILL MIXTURE - 70% NATIVE
SOIL, 30% LEAFMOLD (OR EQUAL).
DO NOT USE PEAT MOSS.
SUPPORT STAKE, 2'-0" MIN.
EMBEDMENT
CUT AND REMOVE TOP HALF OF
ANY WIRE BASKETS OR SPLIT THE
BASKET DOWN THE MIDDLE AND
FOLD INTO THE BOTTOM OF THE
PLANTING PIT.
FORM 3" DEEP EARTH SAUCER
WITH BACKFILL MIX
3" DOUBLE SHREDDED HARDWOOD
MULCH
DOUBLE STRAND TWISTED
MALLEABLE #10 GAGE ANNEALED
STEEL WIRE (TWO REQUIRED)
TWO (2) OR THREE (3) 2"x2" OAK
STAKES. NOTCH STAKES TO HOLD
WIRE
TWO (2) PIECES OF NEW
REINFORCED RUBBER HOSE
UNDISTURBED OR
TAMPED EARTH TO
PREVENT SETTLEMENT
NTS
CONIFEROUS TREE
NOTES:
1. DIG ELLIPTICAL HOLE THREE (3) TIMES THE DIAMETER OF THE TOP OF ROOT BALL. "X"=
DIAMETER OF THE ROOT BALL
2. REMOVE ALL CORD FROM AROUND TRUNK AND REMOVE ALL METAL, PLASTIC, OR BURLAP
FROM TOP 1/3 OF ROOTBALL
3. ALL PLANTS MUST BE PLANTED TO BEAR THE SAME RELATION TO FINISHED GRADE AS IT BORE
TO PREVIOUS EXISTING GRADE AT NURSERY
TREES 6'-8' TREES 8'+
NO STAKING
FOR TREES
UNDER 6'
NTS
SOD
GROUNDCOVER
NTS
NTS
J1
E1
A1
D15
E9
J9
3"-5" DIAMETER SMOOTH
RIVER ROCK IN 4"-5" DEEP
DRIP TRENCH
WEED BARRIER UNDERLAY
SAND TRENCH BED ~2" DEEP
4"X6" CONCRETE WITH FLOAT
FINISH JOINTS AT 24" O.C. -
CONTROL JOISTS AT 8" O.C.
4" TROWEL RADIUS
TURF
NOTES:
1. FORM WORK SHALL BE
APPROVED PRIOR TO
PLACING CONCRETE
2. TOP OF TURF OR ROCK
TO BE 1&1
2" BELOW TOP OF
HEADER
AU
G
U
ST
9, W
2D S2
3F
W
2D
9D
A.
B
LO
XD
O R
F
A.
B
LO
XD
O R
F
D . F
LY
N
N
A.
S
TA
R
R
NTSJ15
8 5/8"
36"
36"
48"
36"
DRAIN
FIXED BOLLARD
BOLLARD 8" SCH 80
CONCRETE FILLED
DIRECTION OF
IMPACT
BOLLARD (OPTIONAL)
CANOPY DRIP TRENCH
8/
/2
3:
:0
PM
P:
\1
\1
-0
\3
- P
LA
N
N
IN
G
G
IS
\0 8_
W O
R
KI
N G
F
IL
ES
\A
U
TO
C
AD
\1
S
U
BM
IS
SI
O N
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF THE WORK. THE DRAWINGS ARE
NOT INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL
PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT
DOCUMENTS, ON THE BASIS OF THE GENERAL PERFORMANCE CRITERIA AND
GENERAL EXTENT OF WORK INDICATED, DESCRIBED OR REQUIRED.
2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE
CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS
NECESSARY OR IMPLIED.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE
WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE
CONDITION.
4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S
PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP. ANY
CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT
TO THE CONTRACTING OFFICER'S ATTENTION PRIOR TO PROCEEDING WITH THE
WORK.
5. THE CONTRACTOR SHALL PROTECT EXISTING, IN-PLACE, AND NEW WORK.
6. ALL WORK NOTED "N.I.C." OR "G.F.G.I." IS MEANT TO EXCLUDE THIS SCOPE OF WORK
FROM THE CONSTRUCTION CONTRACT.
7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE COLLECTION,
SEPARATION, RECYCLE, REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND
RUBBISH.
8. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL NEW AND
EXISTING CONDITIONS, SHOWN. THE CONTRACTOR SHALL NOTIFY THE
CONTRACTING OFFICER IN WRITING OF ANY DIFFERING CONDITIONS BEFORE
COMMENCEMENT OF WORK. COMMENCEMENT OF WORK SHALL CONSTITUTE
ACCEPTANCE OF ALL NEW AND EXISTING CONDITIONS.
9. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN
OVER SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING
OFFICER IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF
WORK.
10. REPETITIVE FEATURES NOT NOTED ON DRAWINGS SHALL BE COMPLETELY PROVIDED
AS IF DRAWN IN FULL.
11. ALL DIMENSIONS INDICATED ARE NOT TO VARY BY MORE THAN 1/8". DIMENSIONS ON
DRAWINGS ARE TAKEN TO/FROM THE LOCATIONS LISTED BELOW UNLESS
OTHERWISE INDICATED: GRIDLINE, FACE OF FINISH OR CENTER LINE OF WINDOW.
12. NFPA 241, STANDARD IS CALLED STANDARD FOR SAFEGUARDING CONSTRUCTION,
ALTERATION, AND DEMOLITION OPERATIONS SHALL BE APPLIED.
13. WALL AND CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE
RATING SHALL BE CONSTRUCTED AS DETAILED OR REFERENCED BY UL OR OTHER
REFERENCE.
14. DIMENSIONS SHOWN TO STRUCTURAL BEAMS AND COLUMNS ARE TO THE
CENTERLINE OF THE MEMBER UNLESS SPECIFICALLY NOTED OHERWISE.
15. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER PRODUCT
MANUFACTURER'S STANDARDS.
16. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL
APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN
NECESSARY BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING
JURISDICTION.
17. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC
CORROSION.
18. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS.
SHEETS ARE TO BE REVIEWED AND NOTES ON ANY ONE SHEET ARE TO BE APPLIED
TO RELATED DRAWINGS AND DETAILS.
19. ALL FINISH AND FIRE RATING REQUIREMENTS INDICATED SHALL APPLY TO THE
ENTIRE LENGTH AND HEIGHT OF THE WALL.
20. WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION WITH DOOR
OPENINGS, THE DOOR WIDTH AND THE DOOR FRAME DETAILS DETERMINE THE
LOCATION OF ADJACENT WALLS AND FRAMES.
21. DETAILS INDICATED FOR CONSTRUCTION ARE TO BE USED FOR ALL LOCATIONS OF
SIMILAR CONSTRUCTION. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT
CANNOT BE DETERMINED, CONSULT THE CONTRACTING OFFICER BEFORE
PROCEEDING WITH THE WORK.
22. THE CONTRACTOR SHALL COORDINATE ALL PENETRATIONS WITH ALL TRADES.
23. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED
FOR MECHANICAL EQUIPMENT AND PLUMBING WORK. ALL ACCESS PANEL
LOCATIONS SHALL BE REVIEWED WITH THE CONTRACTING OFFICER PRIOR TO
PROCEEDING.
24. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE ASSEMBLIES SHALL
BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE
RESISTANCE, FIRE RATING, AND STRUCTURAL INTEGRITY OF THE
ASSEMBLY.
25. ALL APPLICABLE CONSTRUCTION WORK SHALL BE ACCOMPLISHED IN
ACCORDANCE WITH THE APPROVED PLANS IN CONJUNCTION WITH THE
SPECIFICATIONS, AND OTHER INFORMATION CONTAINED IN THIS
DRAWING SET
26. CONTRACTOR SHALL PLAN THEIR WORK TO PROVIDE ADEQUATE
PROTECTION FOR PERSONS AND PROPERTY AT ALL TIMES AND EXECUTE
THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND
PROPERTY AS NECESSARY.
27. CONTRACTOR SHALL CONTINUOUSLY COORDINATE PHASING AND
CONSTRUCTION WITH THE CONTRACTING OFFICER AND PROMPTLY
NOTIFY THE CONTRACTING OFFICE OF ANY DISCREPANCIES AND/OR
CONDITIONS WHICH PREVENT HIM/HER FROM FULFILLING THE TERMS OF
THE CONTRACT.
S S
MECH SPACE NOT IN TEST AREA
CONTINUOUS SELF ADHERED
AIR BARRIER
CONTINUOUS FLUID APPLIED
AIR BARRIER (LAP OVER SELF
ADHERED AIR BARRIER)
CONTINUOUS SELF ADHERED
AIR BARRIER
CONTINUOUS FLUID APPLIED
AIR BARRIER (LAP OVER SELF
ADHERED AIR BARRIER)
INSULATING COATING
WRAP AROUND STL
BENT PLATE END AND
STEEL HSS BEAM
CONTINUOUS
FLUID APPLIED
AIR BARRIER
(CONTINUE OVER
STRUCT STEEL
BENT PLATE)
SEE TYPES
PARTITION VARIES
SEE TYPES
PARTITION VARIES
SEE TYPES
PARTITION VARIES
A7A9
A16A16A16
A14A14
A2A2
A14A14
A1A1 A15A15
A13A13
A10A10
A18A18
A17A17
A5A5
A6A6
A3A3
A4A4
A11A11A12A12
A18A1A18A1A18A1A18A1
B14B14
B3B3
B10B10
B99999999999999999999B9999999999999999999B99999999999B99999999999
B1616B161B161B161
B4B4
B5B5
B2B2
6B666
B1B1
B17B17
B8B8
B16B16
B8B8
B15B15B15B15
B11B11
7777777777B7BB7B77777777777B7777777777
B13B13 B12B12
B17B17
C4C4
C5C5
C9C9
C8C8
C2C2 C22C22
C13C13
C16C16
C7C7
C1444444444444444444444114444441444444444C14CCC111C1444444CC111CCC1111CCC 44111114441111444444C1444411444C1444411444
C1C1 C10C10
C6C6
C16C16C20C20
C20C20
C20CC20CC20C2C20CC20C
C12C12
C21C21
C21C21
C21C21
C15C15
C11C11
C18C18
C19C19
C17C17
C3C3
C21C21
23-T
12 23-T
RRD
AIR
OUT
AIR
IN
RRD
AIR
OUT
AIR
IN
18x304 TIER
18x304 TIER x
T
IE
R
A
IR
IN
24x604 TIER
24x604 TIER
C
C H x3
T
IE
R x3
T
IE
R x
T
IE
R x3
T
IE
R x
T
IE
R x3
T
IE
R x
T
IE
R
S S
H
C
D D
D
DC
D
H
H
C
24x604 TIER
24x544 TIER 24x364 TIER
C W O
C W
IC
W O
C W I
126 122
101105
111 115 130
122B
004A
002B
005B
005A
105B
109B
003A
132B
115B
111B
121 136
126B
130B
103107
002C
P-02 P-03
P-01
MECHANICAL YARD
COVERED WALKWAY CANOPY ABOVE
ENTRANCE CANOPY ABOVE
118B
CANOPY COLUMN (TO BE
COORDINATED WITH STRUCTURAL)
101A
CONCRETE PATH
(SEE CIVIL DWGS)
CONCRETE PATH
(SEE CIVIL DWGS)
BUILDING SIGN
6'- 2"
M
IN
R
EQ
'D
6'
- 4
1/ 4"
6' - 6 3/4" 5' - 2"
2"
8' - 0"
1/
4"
22' - 1 1/4"
7' - 2"
2'
- 1
0 1 /2"
1/
4" 21' - 9 3/4"
7' - 1 3/4"
21' - 7 1/2"
7' - 1 1/2"
35' - 0 1/4"
1/
2"
6'
- 1
1/ 4"
7'
- 9
6'
- 8 1/
4" 6'
- 6 3/
4"
6'
- 1
1/ 4"
7'
- 8
8'
- 7 1/
4" 12' - 4 1/4"
3"
2"
5' - 2 1/4"
3' - 1 1/2"
2' - 0 3/4"
3' - 9 3/4" 3' - 0"
1' - 3 1/4"
3' - 0" 1' - 3 1/4"
3' - 0" 0' - 7"
6' - 10 1/2"
1' - 5 1/4" 3' - 0" 1' - 11"
3' - 0" 1' - 11"
3' - 0" 1' - 5 3/4"
6'
- 5
1/ 2"
3' - 1 1/4" 3' - 0" 4' - 0" 3' - 0" 4' - 0" 3' - 0" 4' - 0" 3' - 0" 2' - 1"
3' - 9 1/4" 3' - 0"
1' - 6"
3' - 0"
1' - 6"
3' - 0"
0' - 7 1/2"
7' - 1 1/2"
7' - 6 3/4"
8'
- 7
1/ 4"
6'
- 9
1/ 2"
3'
- 1
1/ 4"
6'
- 9
1/ 4"
6'
- 1
1"
7'
- 1
1/ 4"
7' - 3"
DOOR TAG
WINDOW TAG
LOUVER TAG
WALL TAG
23-T
12 23-T
RRDRRD 18x304 TIER
18x304 TIER x
T
IE
R
24x604 TIER
24x604 TIER
C
C H x3
TI
E R x
T
IE
R x
T
IE
R x
T
IE
R x
T
IE
R x
T
IE
R x
T
IE
R
S S
H
C
D D
D
DC
D
H
H
C
24x604 TIER
24x544 TIER 24x364 TIER
C W O
C W
IC
W O
C W I
6'
- 2
1/ 4"
35' - 0 1/4"
2' - 1" 3' - 0" 3' - 8" 3' - 0" 3' - 8" 3' - 0" 3' - 8" 3' - 0" 4' - 1 3/4"
7' - 0 3/4"
6'
- 0
3/ 4"
7'
- 6
1/ 4"
6'
- 6
1/ 4"
7'
- 0
1/ 4"
0 1 /2"
34' - 7 1/2"7' - 1 3/4"
6'
- 0
3/ 4"
8'
- 7
9"
0'
- 6
1/ 4"
4"
3"
29' - 7 1/2"
27' - 9 1/2"
1/
2"
0 1
/2"
0"6'
- 6
3/ 4"
9' - 8"
3/
4" 7' - 3 1/4"
2' - 10 3/4" 3' - 0" 4' - 8" 3' - 0" 4' - 8" 3' - 0" 4' - 8" 3' - 0" 5' - 7 1/2"
1' - 10 3/4" 3' - 0" 3' - 8" 3' - 0" 3' - 8" 3' - 0" 4' - 8" 3' - 0" 3' - 1"
34' - 5 1/4"
3/
4"
5 1 /4"
12' - 4 3/4"
2" 9'
- 8 1/
4"
12' - 2 1/4"
20' - 1 1/4"
3'
- 9
9' - 0"
6' - 5 1/2" 2' - 1" 3' - 0" 3' - 1" 3' - 0" 6' - 1" 3' - 1" 3' - 0" 5' - 5 3/4"
1' - 0 3/4"
17' - 11"
1'
- 6
1/ 2"
0'
- 3
1/ 2"
6'
- 1
1/ 2"
9' - 9 1/4"
4'
- 8
1/ 2"
4'
- 1
1/ 2"
8' - 1" 2'
- 0
3/ 4"
14' - 1 1/2"
7'
- 8
1/ 2"
3/
4"
9' - 3 3/4"
5' - 6"
8' - 0 1/2"
2'
- 0
7' - 5 3/4"
6' - 11 1/4"
6'
- 1
0"
6'
- 1
0"
6'
- 9
1/ 4"
DOOR TAG
WINDOW TAG
130 126
005A 005B
002B
004A
115B
111B
003A
132B
123 136
126B
130B
122B
002C
105B
109B
1 2 3 4 4.4 5
B
C
D
6 7 8 9 10
118B
C.1
A
D.1
A-
2B
A-
2A
A-
2B
A-
2A
2 X 2 RETURN DIFFUSER
4 X 2 LIGHT FIXTURES (SEE ELECTRICAL DWGS FOR
SPECIFIC FIXTURE TYPE
GWB CEILING (GWB-1 SEE INTERIORS DWG)
2 X 2 ACOUSTICAL CEILING TILES
(ACT-1 & ACT-2 SEE INTERIORS DWG)
2 X 2 SUPPLY DIFFUSER
2 X 2 EXHAUST GRILL
OCCUPANCY SENSOR
SPEAKER - ROUND
DOWNLIGHT - RECESSED
CANOPY CEILING - VENTED METAL PANEL
2 X 2 SUPPLY DIFFUSER
TYPICAL CEILING
SYMBOL LEGEND
2" RECESSED LINEAR DOWNLIGHT
2 X 2 RETURN DIFFUSER
4' STANDARD INDUSTRIAL LIGHTING FIXTURE
EXIT SIGN
LINEAR SUPPLY DIFFUSER
2 X 2 LIGHT FIXTURES (SEE ELECTRICAL DWGS FOR
SPECIFIC FIXTURE TYPE
ACCESS HATCH
CABINETRY BULKHEAD
(SEE A-503 FOR DETAILS)
NOTES:
1. FOR ALL ELECTRICAL ITEMS COORDINATE W/
ELECTRICAL DWGS.
2. FOR ALL MECHANICAL ITEMS COORDINATE WITH
MECHANICAL DWGS.
3. FOR ANY CONFLICTS IN PLAN OF LIGHT FIXTURES
WITH MECHANICAL EQUIPMENT, MOVE MECHANICAL
EQUIPMENT OVER TO NEAREST CEILING TILE.
CONRACTOR NOT TO MAKE ANY UNNECESSARY CUTS
AGAINST STANDARD CEILING GRID.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
PL
O
T D
AT
E:
FI
LE
L O
C
AT
IO
N
/1 0/
:3
4:
P M
R :\d m s2
7 8
\F H
-C D
C -D
M M
-A .rv t
A-102
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R N
EW
Y
O R
K D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
JK
IM
JK
IM
C he ck er
AU
G
U
ST
9, W
2D S2
3F
W
2D S1
9D
U
SA
G F
O R
T H
AM
IL
TO
N
, N
EW
Y O
R K
PR
O
JE
C
T N
O . 7
3/32" = 1'-0"1 REFLECTED CEILING PLAN
CEILING SCHEDULE
Room No. Room Name Material Area
Height Offset From
Level Comments Description
001 Vestibule GWB-1 84 SF 9' - 5" 002, 002C, 003, 005 Waiting Area, Buggy Storage, Circulation, Reception ACT-1 2102 SF 8' - 0" 002B Public Toilet ACT-1 47 SF 9' - 6" 004 Open Office Area ACT-1 144 SF 8' - 0" 004A Storage ACT-1 30 SF 8' - 9" 005A Isolation Area ACT-1 55 SF 8' - 0" 005B ISO Toilet ACT-1 42 SF 8' - 0" 101 Training Room ACT-1 247 SF 8' - 0" 101A Storage ACT-1 25 SF 8' - 9" 102 Directors Office ACT-1 139 SF 9' - 6" 103 Staff Lounge ACT-1 286 SF 8' - 0" 104 Assistant Directors Office ACT-1 88 SF 9' - 6" 105 Janitor Closet ACT-2 46 SF 8' - 0" 105 Infant/Pretoddler Activity 04 ACT-1 675 SF 8' - 0" 105B Storage ACT-1 48 SF 8' - 9" 107 Nursing Mothers Rm ACT-1 48 SF 8' - 0" 108 Communications GWB-1 116 SF 12' - 10" 109 Infant/Pretoddler Activity 03 ACT-1 688 SF 8' - 0" 109B Storage ACT-1 52 SF 8' - 9" 110 Laundry GWB-1 98 SF 8' - 0" FIRE RATED CEILING
(DETAIL A-602/5)
111 Infant/Pretoddler Activity 01 ACT-1 671 SF 8' - 0" 111B Storage ACT-1 52 SF 8' - 9" 112 Recycle Rm ACT-1 31 SF 8' - 0"
CEILING SCHEDULE
Room No. Room Name Material Area
Height Offset From
Level Comments Description
113 Toilet 01 ACT-1 44 SF 8' - 0" 114 Mechanical Room GWB-1 756 SF 12' - 11" 115 Infant/Pretoddler Activity 02 ACT-1 670 SF 8' - 0" 115B Storage ACT-1 45 SF 8' - 9" 117 CCTV Equipment GWB-1 58 SF 12' - 10" 118 Active Playroom ACT-1 1170 SF 9' - 6" 118B Storage ACT-1 60 SF 9' - 0" 119 EXT Storage ACT-1 51 SF 8' - 9" 120 Kitchen ACT-2 942 SF 9' - 0" 121 EXT Storage ACT-1 41 SF 8' - 9" 122 Outreach/Transitional Care Activity Room ACT-1 1088 SF 8' - 0" 122B Storage ACT-1 59 SF 8' - 9" 123 EXT Storage ACT-1 41 SF 8' - 9" 124 Central Storage ACT-1 95 SF 8' - 9" 126 Preschool/PreK Activity 03 ACT-1 1087 SF 8' - 0" 126B Storage ACT-1 55 SF 8' - 9" 127 Electrical GWB-1 113 SF 12' - 10" 128 Toilet 02 ACT-1 51 SF 8' - 0" 130 Preschool/PreK Activity 02 ACT-1 1095 SF 8' - 0" 130B Storage ACT-1 47 SF 8' - 9" 132 Preschool/PreK Activity 01 ACT-1 1095 SF 8' - 0" 132B Storage ACT-1 51 SF 8' - 9" 134 Ext Storage ACT-1 42 SF 8' - 9" 136 Ext Storage ACT-1 44 SF 8' - 9"
PLAN NORTH
16'8' 32'0
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-1 8' - 0"
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-1 8' - 9" A.F.F.
GWB
9' - 5"
A.F.F.
2'x2' ACT-1
8' - 0" A.F.F.
2'x2' ACT-1 8' - 0"
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-2
8' - 0"
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-1
9' - 6"
A.F.F.
2'x2' ACT-1
9' - 6"
A.F.F.
2'x2' ACT-1
9' - 6"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1 8' - 0"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
GWB
12' - 10"
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-1 8' - 0"
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
GWB
12' - 10"
247 SF
38 SF
002C
660 SF
664 SF
46 SF
631 SF
652 SF
1078 SF
1079 SF
30 SF
004A
47 SF
002B
42 SF
005B
106 SF
146 SF
26 SF
101A
55 SF
005A
46 SF
105B
49 SF
109B
49 SF
91 SF
42 SF
003A
59 SF
53 SF
132B
42 SF
48 SF
46 SF
115B
54 SF
111B
42 SF
48 SF
84 SF
284 SF
116 SF
88 SF
139 SF
A.F.F.
2'x2' ACT-1
8' - 0"
1823 SF
VENTED ALUMN SOFFIT
(SEE A-400 FOR DETAILS)
ALUMN BEAM AND
COLUMN COVER LIGHT FIXTURE
(SEE ELEC DWGS)
A.F.F.
2'x2' ACT-1
8' - 0" A.F.F.
2'x2' ACT-1 8' - 0"
A.F.F.
2'x2' ACT-2
8' - 0"
A.F.F.
2'x2' ACT-1
9' - 6"
A.F.F.
2'x2' ACT-1
9' - 6"
A.F.F.
2'x2' ACT-1
9' - 6"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1 8' - 0"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 9"
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-1
9' - 6" A.F.F.
2'x2' ACT-2 9' - 0"A.F.F.
2'x2' ACT-1 8' - 0"
A.F.F.
GWB
12' - 10"
A.F.F.
GWB_FIRE RATED
8' - 0"
A.F.F.
2'x2' ACT-2
8' - 0"
A.F.F.
GWB
12' - 10"
A.F.F.
2'x2' ACT-1
9' - 0"
A.F.F.
2'x2' ACT-1 8' - 0"
1070 SF
1071 SF
46 SF
1079 SF
92 SF
59 SF
122B
42 SF
30 SF
004A
47 SF
002B
146 SF
41 SF
51 SF
126B
44 SF
130B
51 SF
1823 SF
914 SF
116 SF
88 SF
139 SF
1162 SF
756 SF
97 SF
32 SF
60 SF
118B
113 SF
A.F.F.
2'x2' ACT-1
8' - 0"
A.F.F.
2'x2' ACT-2
9' - 0"
VENTED ALUMN SOFFIT
(SEE A-400 FOR DETAILS)
ALUMN BEAM AND
COLUMN COVER
LIGHT FIXTURE (SEE ELEC DWGS) MECHANICAL YARD
STL MESH COVERING
1 2 3 4 4.4 5
B
C
D
6 7 8 9 10
ASPHALT SHINGLE
CANOPY OVER WALKWAY
3 7/8" / 1'-0"3 7/8" / 1'-0"
4"
1' -0
A-500
/4
7"X7" GUTTER
ASPHALT SHINGLE (COLOR TO
MATCH GARRISON HQ BLDG)
DOWNSPOUT 6"X6"DOWNSPOUT 6"X6"DOWNSPOUT 6"X6"DOWNSPOUT 6"X6"
DOWNSPOUT 6"X6"
DOWNSPOUT 6"X6"
DOWNSPOUT 6"X6" 4" / 1'-0"4" / 1'-0"
A-401
C.1
4" / 1'-0"4" / 1'-0"
4"
1' -0
ASPHALT SHINGLE
ACTIVE PLAYROOM
ENTRANCE CANOPY
ASPHALT SHINGLE
MAIN ENTRANCE CANOPY
MECH YARD
COVERING
1"
1' -0
DOWNSPOUT 6"X6"
A
ROOF FALL
PROTECTION
ROOF FALL PROTECTION
INSTALL PER
MANUFACTURER
INSTRUCTIONS
COLOR TO MATCH
ASPHALT SHINGLES
D.1
A-405
DOWNSPOUT 6"X6"
SNOW GUARD
INSTALL PER
MANUFACTURER
INSTRUCTIONS
COLOR TO MATCH
ASPHALT SHINGLES
SNOW GUARD
COLOR MATCH
ASPHALT SHINGLES
SNOW GUARD
SNOW GUARD
COLOR MATCH
ASPHALT SHINGLES
61' - 8"
ROOF FALL PROTECTION
4"
1' -0
71' - 3"76' - 7"
/2
225' - 0 1/4"
7' - 0" 22' - 6" 22' - 6" 22' - 6" 22' - 6" 1' - 4"4' - 7" 22' - 6" 22' - 6" 22' - 6" 22' - 6" 2' - 11"
4' - 9" 5' - 10"
7"x7" GUTTER
7"x7" GUTTER
GENERAL NOTES:
1. ROOF AND WALL PENETRATIONS/
FLASHING SHALL CONFORM TO ACCEPTED
ROOFING PRACTICES AS DESCRIBED AND
DETAILED IN THE CURRENT EDITION OF
THE NRCA ROOFING AND
WATERPROOFING MANUALS & THE
SMACNA ARCHITECTURAL SHEET METAL
MANUAL. SEE SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
2. ALL ITEMS MOUNTED ON THE ROOF,
INCLUDING VTRs, ETC. SHALL BE PAINTED
TO MATCH THE ROOF COLOR.
3. ALL METAL ITEMS PROTRUDING FROM
THE FACE OF THE BUILDING, SHALL BE
PAINTED TO MATCH FASCIA COLOR.
4. ALL EXPOSED FASTENERS SHALL MATCH
COLOR OF ADJACENT METAL.
5. SEE MECHANICAL DRAWINGS AND
SPECIFICATIONS FOR ACTUAL SIZES AND
LOCATIONS OF MECHANICAL ITEMS.
6. SEE SHEET A-400 & A-401 FOR CANOPY
DETAILS
7. SEE SHEET A-500 & A-502 FOR ROOF
PENETRATION DETAILS AND ALL OTHER
DETAILS
8. 4. DOUBLE ROOF UNDERLAYMENT WITH
STAGGERED ENDLAPS ONLY TO BE
PROVIDED IN ROOF AREAS WITH LESS
THAN 4/12 SLOPE.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
PL
O
T D
AT
E:
FI
LE
L O
C
AT
IO
N
/6 /2
2:
:5
PM
R
:\d m s2
7 8 \F
H -C
D C
-D M
M -A
.rv t
A-104
R O
O F
PL
AN
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R N
EW
Y
O R
K D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
JK
IM
JK
IM
C he ck er
AU
G
U
ST
9, W
2D S2
3F
W
2D S1
9D
U
SA
G F
O R
T H
AM
IL
TO
N
, N
EW
Y O
R K
PR
O
JE
C
T N
O . 7
3/32" = 1'-0"1 ROOF PLAN
PLAN NORTH
16'8' 32'0
FIRST FLOOR
0' - 0"
T.O. STEEL
14' - 8"
T.O. ROOF RIDGE
28' - 7"
ASPHALT SHINGLE (COLOR TO
MATCH GARRISON HQ BLDG)
BRICK VENEER (CLR TO
MATCH GARRISON HQ BLDG
1 2 3 4 4.4 5 6 7 8 9 10 A-204
1 A-204
FIRST FLOOR
0' - 0"
T.O. STEEL
14' - 8"
T.O. ROOF RIDGE
28' - 7"
A-203
A-203
ASPHALT SHINGLE (COLOR TO
MATCH GARRISON HQ BLDG)
EXTERIOR GATE
12344.45678910
BRICK VENEER (CLR TO
MATCH GARRISON HQ BLDG
16'8' 32'0
SCALE: 3/32" = 1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
PL
O
T D
AT
E:
FI
LE
L O
C
AT
IO
N
/6 /2
2:
:3
PM
R
:\d m s2
7 8 \F
H -C
D C
-D M
M -A
.rv t
A-201
EL
EV
AT
IO
N S
-N /S
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R N
EW
Y
O R
K D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
JK
IM
JK
IM
C he ck er
AU
G
U
ST
9, W
2D S2
3F
W
2D S1
9D
U
SA
G F
O R
T H
AM
IL
TO
N
, N
EW
Y O
R K
PR
O
JE
C
T N
O . 7
3/32" = 1'-0"2 SOUTH
3/32" = 1'-0"1 NORTH
0%
S U
BM
IS
SI
O
N
/2 1/
ASPHALT SHINGLE
WALKWAY CANOPY
BRICK COLUMN ENCLOSURE
ASPHALT SHINGLE
CANOPY OVER ACTIVE
PLAYROOM ENTRANCE
BRICK CORBELING
ASPHALT SHINGLE
WALKWAY CANOPY
BRICK COLUMN ENCLOSURE
ASPHALT SHINGLE
CANOPY OVER
MAIN ENTRANCE
1/2" CONTROL JOINT 1/2" CONTROL JOINT 1/2" CONTROL JOINT
1/2" CONTROL JOINT 1/2" CONTROL JOINT 1/2" CONTROL JOINT1/2" CONTROL JOINT
CONDENSER UNIT
(SEE MECH DWGS)
DOOR TAG
WINDOW TAG
1/2" CONTROL JOINT 1/2" CONTROL JOINT 1/2" CONTROL JOINT
PREFABRICATED ALUMINUM ENTABLATURE
CONDENSER UNIT
(SEE MECH DWGS)
LIGHT FIXTURES
(SEE ELEC DWGS)
1/2" CONTROL JOINT
1/2" CONTROL JOINT 1/2" CONTROL JOINT 1/2" CONTROL JOINT
DECORATIVE LOUVER
(INSTALL PER MANUFACTURER'S
INSTRUCTIONS) PREFABRICATED ALUMINUM ENTABLATURE
DECORATIVE BRICK
PILASTER
DOOR TAG
WINDOW TAG
DECORATIVE LOUVER
(INSTALL PER MANUFACTURER'S
INSTRUCTIONS)
CONDENSER UNIT
(SEE MECH DWGS)
1/2" CONTROL JOINT 1/2" CONTROL JOINT 1/2" CONTROL JOINT
DECORATIVE LOUVER
(INSTALL PER MANUFACTURER'S
INSTRUCTIONS)
1/2" CONTROL JOINT1/2" CONTROL JOINT
LIGHT FIXTURE
(SEE ELEC DWGS)
TRAINING
RM
INFANT/PRE-TODDLER
ACTIVITY RM
OPEN
OFFICE
AREASTORAGE
CORRIDOR
ACTIVE
PLAYROOM MECHANICAL
KITCHEN
ASSISTANT
DIRECTORS
OFFICE
PRESCHOOL/PRE-K
ACTIVITY RM
OUTREACH/TRANSITIONAL
CARE
ACTIVITY RM
INFANT/PRE-TODDLER
ACTIVITY RM
INFANT/PRE-TODDLER
ACTIVITY RM
PRESCHOOL/PRE-K
ACTIVITY RM
PRESCHOOL/PRE-K
ACTIVITY RM
02 STORAGESTORAGESTORAGE STORAGE
CORRIDOR
INFANT/PRE-TODDLER
ACTIVITY RM
01 CORRIDOR
INFANT/PRE-TODDLER
ACTIVITY RM
PRESCHOOL/PRE-K
ACTIVITY RM
VESTIBULE
CORRIDOR
WALKWAY CANOPY
PRESCHOOL/PRE-K
ACTIVITY RM
02 COMMUNICATIONS
ASSISTANT
DIRECTORS
OFFICE
DIRECTORS
OFFICE
FIRST FLOOR
0' - 0"
T.O. STEEL
14' - 8"
C
4" BRICK VENEER
RIGID INSULATION
R-12 MIN
CONTINUOUS AIR
BARRIER
5/8" GYP. WALL BOARD
AIR SPACE (2" MIN)
CONCRETE
SLAB-ON-GRADE
(SEE STRUCT DWGS)
CAST-IN PLACE
CONCRETE
(SEE CIVIL DWGS)
ACT CEILING
(SEE CEILING SCHEDULE)
EXTERIOR
INTERIOR
3 5/8" METAL STUD
8" CMU BLOCK WALL
A-504
A-500 4 Sim
C.1
ASPHALT SHINGLE
ROOF
2'-0"
SNOW GUARD
FIRST FLOOR
0' - 0"
T.O. STEEL
14' - 8"
4" BRICK VENEER
RIGID INSULATION
R-12 MIN
8" CMU BLOCK WALL
AIR SPACE (2" MIN)
CONCRETE
SLAB-ON-GRADE
(SEE STRUCT DWGS)
CONCRETE WALKWAY
(SEE CIVIL DWGS)
ACT CEILING
(SEE CEILING SCHEDULE)
3 5/8" METAL STUD
5/8" GYP.
WALL BOARD
C
EXTERIOR
INTERIOR
CONTINUOUS
AIR BARRIER
PRECAST KEYSTONE
A-404
PRECAST WINDOW SILL
WINDOW
(AS SCHEDULED)
C.1
QUARTZ
WINDOW SILL, TYP.
ROUND ALL CORNERS
AND EDGS.
ALUMN CORNICE
ASPHALT SHINGLE
ROOF
TY
P
1'
6" A
FF
M
IN
2'-0"
A-500
DOVE TAIL
ANCHOR 16" O.C.
A-012
A-012
A-404
FIRST FLOOR
0' - 0"
T.O. STEEL
14' - 8"
CC.1
A-504
CONCRETE
SLAB-ON-GRADE
SEE STRUCT DWGS
GYP. CEILING
(SEE CEILING SCHEDULE)
GRAVEL (MECH YARD)
(SEE CIVIL DWGS)
4" BRICK VENEER
RIGID INSULATION
R-12 MIN
CONTINUOUS
AIR BARRIER
AIR SPACE (2" MIN)
8" CMU BLOCK WALL
ASPHALT SHINGLE
ROOF (TYP)
SNOW GUARD 4
2'-0"
SST MTL FLASHING
WITH WEEPS 24" O.C.
5/8" GYP. WALL BOARD
3 5/8" METAL STUD
MECH YARD
MESH COVERING
(SEE A-403 FOR DTLS)
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
PL
O
T D
AT
E:
FI
LE
L O
C
AT
IO
N
/6 /2
2:
:0
PM
R
:\d m s2
7 8 \F
H -C
D C
-D M
M -A
.rv t
A-310
W
AL
L
SE
C
TI
O N
S
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R N
EW
Y
O R
K D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
JK
IM
JK
IM
C he ck er
AU
G
U
ST
9, W
2D S2
3F
W
2D S1
9D
U
SA
G F
O R
T H
AM
IL
TO
N
, N
EW
Y O
R K
PR
O
JE
C
T N
O . 7
3/4" = 1'-0"1 EXT WALL SECTION TYP.
3/4" = 1'-0"2 EXT WALL SECTION @ WINDOW TYP
2'1' 4'0
SCALE: 3/4" = 1'-0"
3/4" = 1'-0"3 EXT WALL SECTION @ KITCHEN
CONCRETE WALKWAY
(SEE CIVIL DWGS)
CEMENT BOARD
ASPHALT SHINGLE
ROOF
DECORATIVE
METAL LOUVER
(INSTALL AS PER
MANUFACTURERS DETAILS)
BOND BEAM
(SEE STRUCTURAL DWGS)
EXTERIORINTERIOR
INSULATION COATING
(ON STL BENTPLATE
UNDERSIDE)
3 5/8" STUD
W/ BATT INSULATION
STL ANGLE
(SEE STRUCT DWGS)
CONCRETE
SLAB-ON-GRADE
SEE STRUCT DWGS
GRAVEL (MECH YARD)
(SEE CIVIL DWGS)
SST MTL FLASHING
WITH WEEPS 24" O.C.
M
IN
(T
YP
0"
A .F
.F
LOUVER
SEE LOUVER
SCHEDULE
4" BRICK VENEER
RIGID INSULATION
R-12 MIN
2" AIR SPACE
8" CMU BLOCK WALL
3" RIGID INSULATION
R-15 FOR 24"
ASPHALT SHINGLE
ROOF
SNOW GUARD
2'
- 8
BRICK CORBEL
ALUM
CORNICE
STEEL ANGLE
(SEE STRUCT DWG)
TY
P
1'
- 6
" A
FF
M
IN
CORDLESS MANUAL WINDOW
SHADE WITH FASCIA. PROVIDE
UNIVERSAL MOUNTING BRACKETS
FOR JAMB INSTALLATION PER
MANUFACTURER’S INSTRUCTIONS.
(SEE INTERIOR DRAWINGS FOR
FINISH LEGEND AND LOCATIONS
OF WINDOW SHADES)
7'
- 1
3/ 4"
4" BRICK VENEER
RIGID INSULATION
R-12 MIN
AIR SPACE (2" MIN)
8" CMU BLOCK WALL
CONTINUOUS AIR
BARRIER
PRECAST
ARCH LINTEL
CONCRETE
SLAB-ON-GRADE
SEE STRUCT DWGS
CONCRETE WALKWAY
(SEE CIVIL DWGS)
3" RIGID INSULATION
R-15 FOR 24"
PRECAST WINDOW SILL
WINDOW
(AS SCHEDULED)
PRECAST
KEYSTONE
DOVE TAIL
ANCHOR 16" O.C.
5/8" GYP. WALL BOARD
3 5/8" METAL STUD
ACT CEILING
(SEE CEILING SCHEDULE)
ALUMN CORNICE
ASPHALT SHINGLE
COVERING
VESTIBULE
HSS STEEL COLUMN (SEE STRUCT DWGS)
BRICK ENCLOSURE
WALK OFF MAT
(SEE INTERIORS DWGS)
CONCRETE PATH
(SEE CIVIL DWGS)
LIGHT FIXTURE
(SEE ELEC DWGS)
VESTIBULE
4' - 3"
A-401A-401
0' - 5"
TY
P
0'
- 4
" M
IN
TY
P
2'
- 4
" M
IN
TY
P
0'
- 9
" M
IN
ALUMN VENTED SOFFIT
EXIT DOOR
THRESHOLD
GYP CEILING
DECORATIVE LOUVER
LIGHT FIXTURE
(SEE ELEC DWGS)
GROUT INFILL
METAL ANGLE TO CONTAIN
INSULATION
ASPHALT ROOF SHINGLE
STEEL BENT PLATE
(SEE STRUCT DWGS)
INSULATION COATING
(ON STL BENTPLATE UNDERSIDE)
METAL DECK
3" METAL DECK
3 5/8" METAL STUD
CONTINUOUS AIR
BARRIER
CONTINUOUS AIR BARRIER
OVERLAP FLUID APPLIED
AND SELF ADHERED
AIR BARRIERS
5/8" GYP WALL
BOARD
GYP CEILING
3" RIGID INSULATION
R-15 FOR 24"
5/8" GYP. WALL BOARD
2" AIR SPACE
METAL CAP
VENTED METAL
CEILING
3" METAL DECK
CONCRETE
SLAB-ON-GRADE
(SEE STRUCT DWGS)
1/2" EXT GRADE
PLYWOOD
4" BRICK VENEER
RIGID INSULATION R-15
ALCOVE LIGHT FIXTURE
SEE RCP FOR LOCATION
SEE ELEC DWGS FOR FIXTURE
SPRAY FOAM AIR BARRIER
INSIDE END FLUTES
(BOTH SIDES)
5/8" GYP. WALL
BOARD
2" AIR SPACE
METAL CAP
CONTINUOUS AIR BARRIER
1/2" EXT GRADE
PLYWOOD
3 5/8" STEEL STUD
3" RIGID INSULATION
R-15
4" BRICK VENEER
6" STEEL STUD
CONTINUOUS AIR BARRIER
R-13 MINERAL WOOL BATT
INSULATION
3" RIGID INSULATION
R-15
5/8" GYP BOARD
CONTINUOUS
CONTINUOUS AIR BARRIER
(OVERLAP FLUID APPLIED
WITH SELF ADHERED
AIR BARRIER)
EXT WALL TYP
SE
E
DE
TA
IL
A-
2/4
EX
T
W
AL
L
5/8" GYP BOARD
CONTINUOUS
SE
E
DO
OR
S
CH
ED
UL
E
EX
T
DO
OR
EXT WALL TYP
SE
E
DE
TA
IL
A-
2/4
EX
T
W
AL
L
23-T12
AIR
IN
AIR
IN
TIER
TIER
TIER
CL
EA
RA
N C
E
4'
- 0
" M
IN
CLEARANCE
3' - 5" MIN
CLEARANCE
3' - 5" MIN
CL
EA
RA
NC
E 4'
- 0 " M
IN
CLEARANCE
5' - 1" MIN
CLEARANCE
3' - 0" MIN
CLEARANCE
3' - 0" MIN
CL
EA
RA
NC
E
0"
M
IN
CHAIN LINK MESH
~ 765 SQ. FT
ASSUMING 5 PSF
~ 4 KIPS
PERIMETER TUBE TO BE
ATTACHED TO MECH
SCREEN PANEL AND BRICK
VENEER (TYP.). MIN NPS 8
STD.
MAIN TUBE TO SPAN
BETWEEN PERIMETER AND
CENTER COLUMN (TYP.)
MIN NPS 8 STD
STEEL TUBE COLUMN.
MUST BE AT LEAST
PIPE NPS 3.5 WITH FY=
35 KSI FOR STRENGTH.
USE NPS 8
'-0
CHAIN LINK MESH
~ 765 SQ. FT
ASSUMING 5 PSF
~ 4 KIPS
STRINGER TUBE TO SPAN
BETWEEN PERIMETER AND
MAIN TUBE (TYP.)
MIN NPS 6 STD
CHAIN LINK BRACE
(TYP.)
MAIN TUBE TO SPAN
BETWEEN PERIMETER AND
STIFFENER TUBE (TYP.)
MIN NPS 8 STD
MID TUBE TO SPAN
BETWEEN PERIMETER AND
STRINGER (TYP.)
MIN NPS 8 STD
MID TUBE TO SPAN
BETWEEN PERIMETER AND
STRINGER (TYP.)
MIN NPS 8 STD
CONNECT PERIMETER
TUBE TO BRICK VENEER
WITH U-BOLT ANCHORS
CONNECT PERIMETER
TUBE TO MECH SCREEN
PANEL WITH U-BOLTS
File details come from the government source that posted it. Updated .