About this file

This document is Section 01 50 00 Temporary Construction Facilities and Controls from a government construction contract. It outlines the requirements for temporary facilities, signage, traffic control, cybersecurity, and other provisions needed during construction.

Key details include:

  • Contractor must submit site plans, traffic control plans, haul road plans, and cybersecurity compliance statements for government approval prior to starting work.
  • Contractor must provide and maintain temporary utilities, sanitation facilities, temporary wiring, and backflow preventers that meet specified standards.
  • Contractor must follow Department of Defense readiness condition requirements for securing the site in advance of severe weather.
  • Contractor must comply with detailed cybersecurity requirements for any contractor-owned computers and temporary IP networks used on the project.
  • The government will provide a field office with specified furniture, equipment, and services for the Contracting Officer's use during the project.

View the file

Other files

File Type Posted
C.04.01 24B0017 FIMI Bid Abstract.Rev1.pdf PDF
amendment 0005.pdf PDF
B.08.03+Amendment+04.pdf PDF
B.08.03 Amendment 03.pdf PDF
Amend 3_01_35_26.pdf PDF
Amend 3_00 31 32.06 18.pdf PDF
01 14 00_Amend2.pdf PDF
01 35 26_Amend2.pdf PDF
B.08.03 Amendment 02.pdf PDF
00 31 24.01 18_Amend2.pdf PDF
31 24 00.00 18_Amend2.pdf PDF
31 62 19_Amend2.pdf PDF
01 20 00_Amend2.pdf PDF
00 31 32.06 18_Amend2.pdf PDF
01 78 00_Amend2.pdf PDF
35 20 23_Amend 2.pdf PDF
06 13 00_Amend2.pdf PDF
Borrow 2C ENElev_Navd88.txt TXT text file
Amend 2 FIMI PIR 2024 Plans.pdf PDF
01 57 19_Amend2.pdf PDF
35 20 23.23_Amend 2.pdf PDF
01 11 00_Amend2.pdf PDF
B.08.03 Amendment 01.pdf PDF
B.08.03 01 30 00.pdf PDF
A.03.09 95pct_FIMI PIR 2024 DDR.pdf PDF
A.03.09 May 31 FIMI PIR 2024 Plans.pdf PDF
A.03.09 ECIFP_FIMI.pdf PDF
A.03.09 PL8499_FIMI_PIR_95_PCNT_SPEC_05-31-2024.pdf PDF
B.08.03 Invitation for Bid W912DS24B0017.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PL 84- 99 FI MI - Ocean Bay Par k t o Davi s Par k PL8499FI MI Amendment 02

SECTI ON 01 50 00

TEMPORARY CONSTRUCTI ON FACI LI TI ES AND CONTROLS

11/ 20, CHG 2: 08/ 22

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

AMERI CAN WATER WORKS ASSOCI ATI ON ( AWWA)

AWWA C511 ( 2017; R 2021) Reduced- Pr essur e Pr i nci pl e Backf l ow Pr event i on Assembl y

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 70 ( 2023; ERTA 4 2023) Nat i onal El ect r i cal Code

NFPA 241 ( 2022) St andar d f or Saf eguar di ng Const r uct i on, Al t er at i on, and Demol i t i on Oper at i ons

U. S. ARMY CORPS OF ENGI NEERS ( USACE)

EM 385- 1- 1 ( 2014) Saf et y - - Saf et y and Heal t h Requi r ement s Manual

U. S. FEDERAL HI GHWAY ADMI NI STRATI ON ( FHWA)

MUTCD ( 2009; Rev 2012) Manual on Uni f or m Tr af f i c Cont r ol Devi ces

1. 2 SUBMI TTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" or " S" c l assi f i cat i on. Submi t t al s not havi ng a " G" or " S" c l assi f i cat i on ar e f or i nf or mat i on onl y. When used, a code f ol l owi ng t he " G" c l assi f i cat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment .

Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL

PROCEDURES:

SD- 01 Pr econst r uct i on Submi t t al s

Const r uct i on Si t e Pl an; G, RO

Tr af f i c Cont r ol Pl an; G, RO

Haul Road Pl an; G, RO

Cont r act or Comput er Cyber secur i t y Compl i ance St at ement s; G, RO

Cont r act or Tempor ar y Net wor k Cyber secur i t y Compl i ance St at ement s; G, SECTI ON 01 50 00 Page 1

RO

SD- 06 Test Repor t s

Backf l ow Pr event er Test s

SD- 07 Cer t i f i cat es

Backf l ow Test er Cer t i f i cat i on

Backf l ow Pr event er s Cer t i f i cat e of Ful l Appr oval

1. 3 CONSTRUCTI ON SI TE PLAN

Pr i or t o t he st ar t of wor k, submi t f or Gover nment appr oval a s i t e pl an showi ng t he l ocat i ons and di mensi ons of t empor ar y f aci l i t i es ( i ncl udi ng l ayout s and det ai l s, equi pment and mat er i al st or age ar ea ( onsi t e and of f s i t e) , and access and haul r out es, avenues of i ngr ess/ egr ess t o t he f enced ar ea and det ai l s of t he f ence i nst al l at i on. I dent i f y any ar eas whi ch may have t o be gr avel ed t o pr event t he t r acki ng of mud. I ndi cat e i f t he use of a suppl ement al or ot her st agi ng ar ea i s desi r ed. Show l ocat i ons of saf et y and const r uct i on f ences, s i t e t r ai l er s, const r uct i on ent r ances, t r ash dumpst er s, t empor ar y sani t ar y f aci l i t i es, and wor ker par ki ng ar eas.

1. 4 BACKFLOW PREVENTERS CERTI FI CATE

1. 4. 1 Backf l ow Test er Cer t i f i cat e

Pr i or t o t est i ng, submi t t o t he Cont r act i ng Of f i cer cer t i f i cat i on i ssued by t he St at e or l ocal r egul at or y agency at t est i ng t hat t he backf l ow t est er has successf ul l y compl et ed a cer t i f i cat i on cour se sponsor ed by t he r egul at or y agency. Test er must not be af f i l i at ed wi t h a company par t i c i pat i ng i n ot her phases of t hi s Cont r act .

1. 4. 2 Backf l ow Pr event i on Tr ai ni ng Cer t i f i cat e

Submi t a cer t i f i cat e r ecogni zed by t he St at e or l ocal aut hor i t y t hat st at es t he Cont r act or has compl et ed at l east 10 hour s of t r ai ni ng i n backf l ow pr event er i nst al l at i ons. The cer t i f i cat e must be cur r ent .

1. 5 DOD CONDI TI ON OF READI NESS ( COR)

DOD wi l l set t he Condi t i on of Readi ness ( COR) based on t he weat her f or ecast f or sust ai ned wi nds 50 knot s ( 58 mph) or gr eat er . Cont act t he Cont r act i ng Of f i cer f or t he cur r ent COR set t i ng.

Moni t or weat her condi t i ons a mi ni mum of t wi ce a day and t ake appr opr i at e act i ons accor di ng t o t he appr oved Emer gency Pl an i n t he accept ed Acci dent Pr event i on Pl an, EM 385- 1- 1 Sect i on 01 Emer gency Pl anni ng and t he i nst r uct i ons bel ow.

Unl ess ot her wi se di r ect ed by t he Cont r act i ng Of f i cer , compl y wi t h:

a. Condi t i on FOUR ( Sust ai ned wi nds of 58 mph or gr eat er expect ed wi t hi n 72 hour s) : Nor mal dai l y j obsi t e c l eanup and good housekeepi ng pr act i ces. Col l ect and st or e i n pi l es or cont ai ner s scr ap l umber , wast e mat er i al , and r ubbi sh f or r emoval and di sposal at t he c l ose of

SECTI ON 01 50 00 Page 2 each wor k day. Mai nt ai n t he const r uct i on s i t e i ncl udi ng st or age ar eas, f r ee of accumul at i on of debr i s. St ack f or m l umber i n neat pi l es l ess t han 3. 3 f eet hi gh. Remove al l debr i s, t r ash, or obj ect s t hat coul d become mi ssi l e hazar ds. Revi ew r equi r ement s per t ai ni ng t o " Condi t i on THREE" and cont i nue act i on as necessar y t o at t ai n " Condi t i on FOUR" r eadi ness. Cont act Cont r act i ng Of f i cer f or weat her and COR updat es and compl et i on of r equi r ed act i ons.

b. Condi t i on THREE ( Sust ai ned wi nds of 58 mph or gr eat er expect ed wi t hi n 48 hour s) : Mai nt ai n " Condi t i on FOUR" r equi r ement s and commence secur i ng oper at i ons necessar y f or " Condi t i on ONE" whi ch cannot be compl et ed wi t hi n 18 hour s. Cease al l r out i ne act i v i t i es whi ch mi ght i nt er f er e wi t h secur i ng oper at i ons. Commence secur i ng and st ow al l gear and por t abl e equi pment . Make pr epar at i ons f or secur i ng bui l di ngs. Rei nf or ce or r emove f or mwor k and scaf f ol di ng. Secur e machi ner y, t ool s, equi pment , mat er i al s, or r emove f r om t he j obsi t e.

Expend ever y ef f or t t o c l ear al l mi ssi l e hazar ds and l oose equi pment f r om gener al base ar eas. Cont act Cont r act i ng Of f i cer f or weat her and COR updat es and compl et i on of r equi r ed act i ons. Revi ew r equi r ement s per t ai ni ng t o " Condi t i on TWO" and cont i nue act i on as necessar y t o at t ai n " Condi t i on THREE" r eadi ness.

c. Condi t i on TWO ( Sust ai ned wi nds of 58 mph or gr eat er expect ed wi t hi n 24 hour s) : Secur e t he j obsi t e, and l eave Gover nment pr emi ses.

d. Condi t i on ONE. ( Sust ai ned wi nds of 58 mph or gr eat er expect ed wi t hi n 12 hour s) : Cont r act or access t o t he j obsi t e and Gover nment pr emi ses i s pr ohi bi t ed.

1. 6 CYBERSECURI TY DURI NG CONSTRUCTI ON

{ For Ref er ence Onl y: Thi s subpar t ( and i t s subpar t s) r el at es t o AC- 18, SA- 3, CCI - 00258. } Meet t he f ol l owi ng r equi r ement s t hr oughout t he const r uct i on pr ocess.

1. 6. 1 Cont r act or Comput er Equi pment

Cont r act or owned comput er s may be used f or const r uct i on. When used, cont r act or comput er s must meet t he f ol l owi ng r equi r ement s:

1. 6. 1. 1 Oper at i ng Syst em

The oper at i ng syst em must be an oper at i ng syst em cur r ent l y suppor t ed by t he manuf act ur er of t he oper at i ng syst em. The oper at i ng syst em must be cur r ent on secur i t y pat ches and oper at i ng syst em manuf act ur er r equi r ed updat es.

1. 6. 1. 2 Ant i - Mal war e Sof t war e

The comput er must r un ant i - mal war e sof t war e f r om a r eput abl e sof t war e manuf act ur er . Ant i - mal war e sof t war e must be a ver si on cur r ent l y suppor t ed by t he sof t war e manuf act ur er , must be cur r ent on al l pat ches and updat es, and must use t he l at est def i ni t i ons f i l e. Al l comput er s used on t hi s pr oj ect must be scanned usi ng t he i nst al l ed sof t war e at l east once per day.

1. 6. 1. 3 Passwor ds and Passphr ases

The passwor ds and passphr ases f or al l comput er s must be changed f r om t hei r

SECTI ON 01 50 00 Page 3 def aul t val ues. Passwor ds must be a mi ni mum of ei ght char act er s wi t h a mi ni mum of one upper case l et t er , one l ower case l et t er , one number and one speci al char act er .

1. 6. 1. 4 Cont r act or Comput er Cyber secur i t y Compl i ance St at ement s

Pr ovi de a s i ngl e submi t t al cont ai ni ng compl et ed Cont r act or Comput er Cyber secur i t y Compl i ance St at ement s f or each company usi ng cont r act or owned comput er s. Cont r act or Comput er Cyber secur i t y Compl i ance St at ement s must use t he t empl at e publ i shed at ht t p: / / www. wbdg. or g/ f f c/ dod/ uni f i ed-f aci l i t i es- gui de- speci f i cat i ons- uf gs/ f or ms- gr aphi cs- t abl es. Each St at ement must be si gned by a cyber secur i t y r epr esent at i ve f or t he r el evant company.

1. 6. 2 Tempor ar y I P Net wor ks

Tempor ar y cont r act or - i nst al l ed I P net wor ks may be used dur i ng const r uct i on. When used, t empor ar y cont r act or - i nst al l ed I P net wor ks must meet t he f ol l owi ng r equi r ement s:

1. 6. 2. 1 Net wor k Boundar i es and Connect i ons

The net wor k must not ext end out si de t he pr oj ect s i t e and must not connect t o any I P net wor k ot her t han I P net wor ks pr ovi ded under t hi s pr oj ect or Gover nment f ur ni shed I P net wor ks pr ovi ded f or t hi s pur pose. Any and al l net wor k access f r om out si de t he pr oj ect s i t e i s pr ohi bi t ed.

1. 6. 3 Gover nment Access t o Net wor k

Gover nment per sonnel , as def i ned, pr escr i bed, and i dent i f i ed by t he Cont r act i ng Of f i cer , must be al l owed t o have compl et e and i mmedi at e access t o t he net wor k at any t i me i n or der t o ver i f y compl i ance wi t h t hi s speci f i cat i on. Or i f t her e i s a Gover nment agency t hat ' s r esponsi bl e, i dent i f y t hat agency.

1. 6. 4 Tempor ar y Wi r el ess I P Net wor ks

I n addi t i on t o t he ot her r equi r ement s on t empor ar y I P net wor ks, t empor ar y wi r el ess I P ( Wi Fi ) net wor ks must not i nt er f er e wi t h exi st i ng wi r el ess net wor k and must use WPA2 secur i t y. Net wor k names ( SSI D) f or wi r el ess net wor ks must be changed f r om t hei r def aul t val ues.

1. 6. 5 Passwor ds and Passphr ases

The passwor ds and passphr ases f or al l net wor k devi ces and net wor k access must be changed f r om t hei r def aul t val ues. Passwor ds must be a mi ni mum 8 char act er s wi t h a mi ni mum of one upper case l et t er , one l ower case l et t er , one number and one speci al char act er .

1. 6. 6 Cont r act or Tempor ar y Net wor k Cyber secur i t y Compl i ance St at ement s

Pr ovi de a s i ngl e submi t t al cont ai ni ng compl et ed Cont r act or Tempor ar y Net wor k Cyber secur i t y Compl i ance St at ement s f or each company i mpl ement i ng a t empor ar y I P net wor k. Cont r act or Tempor ar y Net wor k Cyber secur i t y Compl i ance St at ement s must use t he t empl at e publ i shed at ht t p: / / www. wbdg. or g/ f f c/ dod/ uni f i ed- f aci l i t i es- gui de- speci f i cat i ons- uf gs/ f or ms- gr aphi cs- t abl es. Each St at ement must be si gned by a cyber secur i t y r epr esent at i ve f or t he r el evant company. I f no t empor ar y I P net wor ks wi l l be used, pr ovi de a s i ngl e copy of t he St at ement i ndi cat i ng t hi s.

SECTI ON 01 50 00 Page 4

PART 2 PRODUCTS

2. 1 TEMPORARY SI GNAGE

2. 1. 1 Bul l et i n Boar d

Pr i or t o t he commencement of wor k act i v i t i es, pr ovi de a c l ear weat her pr oof cover ed bul l et i n boar d not l ess t han 36 by 48 i nches i n s i ze f or di spl ayi ng t he Equal Empl oyment Oppor t uni t y post er , a copy of t he wage deci s i on cont ai ned i n t he Cont r act , Wage Rat e I nf or mat i on post er , Saf et y and Heal t h I nf or mat i on as r equi r ed by EM 385- 1- 1 Sect i on 01 and ot her i nf or mat i on appr oved by t he Cont r act i ng Of f i cer . Coor di nat e r equi r ement s her ei n wi t h 01 35 26 GOVERNMENTAL SAFETY REQUI REMENTS. Locat e t he bul l et i n boar d at t he pr oj ect s i t e i n a conspi cuous pl ace easi l y accessi bl e t o al l empl oyees, and i n l ocat i on as appr oved by t he Cont r act i ng Of f i cer .

2. 1. 2 Pr oj ect I dent i f i cat i on Si gns

The r equi r ement s f or t he s i gns, t hei r cont ent , and l ocat i on ar e as speci f i ed i n Sect i on 01 58 00 PROJECT I DENTI FI CATI ON. Er ect s i gns wi t hi n 15 days af t er r ecei pt of t he not i ce t o pr oceed. Cor r ect t he dat a r equi r ed by t he saf et y s i gn dai l y, wi t h l i ght col or ed met al l i c or non- met al l i c numer al s.

2. 1. 3 War ni ng Si gns

Post t empor ar y s i gns, t ags, and l abel s t o gi ve wor ker s and t he publ i c adequat e war ni ng and caut i on of const r uct i on hazar ds accor di ng t o t he EM 385- 1- 1 Sect i on 04. At t ach si gns t o t he per i met er f enci ng ever y 150 f eet war ni ng t he publ i c of t he pr esence of const r uct i on hazar ds. Si gns must r equi r e unaut hor i zed per sons t o keep out of t he const r uct i on s i t e.

Cor r ect t he dat a r equi r ed by saf et y s i gns dai l y. Post s i gns at al l poi nt s of ent r y desi gnat i ng t he const r uct i on s i t e as a har d hat ar ea.

2. 2 TEMPORARY TRAFFI C CONTROL

2. 2. 1 Haul Roads

Const r uct access and haul r oads necessar y f or pr oper pr osecut i on of t he wor k under t hi s Cont r act i n accor dance wi t h EM 385- 1- 1 Sect i on 04.

Const r uct wi t h sui t abl e gr ades and wi dt hs; avoi d shar p cur ves, bl i nd cor ner s, and danger ous cr oss t r af f i c . Submi t haul r oad pl an f or appr oval . Pr ovi de necessar y l i ght i ng, s i gns, bar r i cades, and di st i nct i ve mar ki ngs f or t he saf e movement of t r af f i c . The met hod of dust cont r ol , al t hough opt i onal , must be adequat e t o ensur e saf e oper at i on at al l t i mes. Locat i on, gr ade, wi dt h, and al i gnment of const r uct i on and haul r oads ar e subj ect t o appr oval by t he Cont r act i ng Of f i cer . Li ght i ng must be adequat e t o assur e f ul l and cl ear v i s i bi l i t y f or f ul l wi dt h of haul r oad and wor k ar eas dur i ng any ni ght wor k oper at i ons.

2. 2. 2 Bar r i cades

Er ect and mai nt ai n t empor ar y bar r i cades t o l i mi t publ i c access t o hazar dous ar eas. Bar r i cades ar e r equi r ed whenever saf e publ i c access t o paved ar eas such as r oads, par ki ng ar eas or s i dewal ks i s pr event ed by const r uct i on act i v i t i es or as ot her wi se necessar y t o ensur e t he saf et y of bot h pedest r i an and vehi cul ar t r af f i c . Secur el y pl ace bar r i cades cl ear l y

SECTI ON 01 50 00 Page 5 vi s i bl e wi t h adequat e i l l umi nat i on t o pr ovi de suf f i c i ent v i sual war ni ng of t he hazar d dur i ng bot h day and ni ght .

2. 3 FENCI NG

Pr ovi de f enci ng al ong t he const r uct i on s i t e and at al l open excavat i ons and t unnel s t o cont r ol access by unaut hor i zed per sonnel . Saf et y f enci ng must be hi ghl y v i s i bl e t o be seen by pedest r i ans and vehi cul ar t r af f i c .

Al l f enci ng must meet t he r equi r ement s of EM 385- 1- 1. Remove t he f ence upon compl et i on and accept ance of t he wor k.

2. 3. 1 Pol yet hyl ene Mesh Saf et y Fenci ng

Tempor ar y saf et y f enci ng must be a hi gh vi s i bi l i t y or ange col or ed, hi gh densi t y pol yet hyl ene gr i d, a mi ni mum of 48 i nches hi gh and maxi mum mesh si ze of 2 i nches. Fenci ng must ext end f r om t he gr ade t o a mi ni mum of 48 i nches above t he gr ade and be t i ght l y secur ed t o T- post s spaced as necessar y t o mai nt ai n a r i gi d and t aut f ence. Fenci ng must r emai n r i gi d and t aut wi t h a mi ni mum of 200 pounds of f or ce exer t ed on i t f r om any di r ect i on wi t h l ess t han 4 i nches of def l ect i on.

2. 3. 2 Chai n Li nk Panel Fenci ng

Tempor ar y panel f enci ng must be gal vani zed st eel chai n l i nk panel s 6 f eet hi gh. Mul t i pl e f enci ng panel s may be l i nked t oget her at t he bases t o f or m l ong spans as needed. Each panel base must be wei ght ed down usi ng sand bags or ot her sui t abl e mat er i al s i n or der f or t he f enci ng t o wi t hst and ant i c i pat ed wi nds whi l e r emai ni ng upr i ght . Fenci ng must r emai n r i gi d and t aut wi t h a mi ni mum of 200 pounds of f or ce exer t ed on i t f r om any di r ect i on wi t h l ess t han 4 i nches of def l ect i on.

2. 3. 3 Post - Dr i ven Chai n Li nk Fenci ng

Tempor ar y post - dr i ven f enci ng must be gal vani zed chai n l i nk f enci ng 6 f eet hi gh suppor t ed by an t i ght l y secur ed t o gal vani zed st eel post s dr i ven bel ow gr ade. Fence post s must be l ocat ed on mi ni mum 10 f oot cent er s.

Post s may be set i n var i ous sur f aces such as sand, soi l , asphal t or concr et e as necessar y. Chai n l i nk f enci ng must r emai n r i gi d and t aut wi t h a mi ni mum of 200 pounds of f or ce exer t ed on i t f r om any di r ect i on wi t h l ess t han 4 i nches of def l ect i on. Compl et el y r emove f enci ng and post s at t he compl et i on of const r uct i on and r est or e sur f aces di st ur bed or damaged t o i t s or i gi nal condi t i on. Locat e and i dent i f y under gr ound ut i l i t i es pr i or t o set t i ng f ence post s. Equi p f ence wi t h a l ockabl e gat e. Gat e must r emai n l ocked when const r uct i on per sonnel ar e not pr esent .

2. 4 TEMPORARY WI RI NG

Pr ovi de t empor ar y wi r i ng i n accor dance wi t h EM 385- 1- 1 Sect i on 11, NFPA 241 and NFPA 70. I ncl ude mont hl y i nspect i on and t est i ng of al l equi pment and appar at us.

2. 5 BACKFLOW PREVENTERS

Cer t i f i cat e of Ful l Appr oval f r om FCCCHR Li st , Uni ver si t y of Sout her n Cal i f or ni a, at t est i ng t hat t he desi gn, s i ze and make of each backf l ow pr event er has sat i sf act or i l y passed t he compl et e sequence of per f or mance t est i ng and eval uat i on f or t he r espect i ve l evel of appr oval . Cer t i f i cat e of Pr ovi s i onal Appr oval i s not accept abl e.

SECTI ON 01 50 00 Page 6

Reduced pr essur e pr i nci pl e t ype conf or mi ng t o t he appl i cabl e r equi r ement s AWWA C511. Pr ovi de backf l ow pr event er s compl et e wi t h 150 pound f l anged cast i r on, br onze, mount ed gat e val ve and st r ai ner , 304 st ai nl ess st eel or br onze, i nt er nal par t s.

PART 3 EXECUTI ON

3. 1 EMPLOYEE PARKI NG

Const r uct i on Cont r act empl oyees must par k pr i vat el y owned vehi c l es i n an ar ea desi gnat ed by t he Cont r act i ng Of f i cer . Empl oyee par ki ng must not i nt er f er e wi t h exi st i ng and est abl i shed par ki ng r equi r ement s of t he Gover nment i nst al l at i on.

3. 2 AVAI LABI LI TY AND USE OF UTI LI TY SERVI CES

3. 2. 1 Tempor ar y Ut i l i t i es

Pr ovi de and mai nt ai n, f or const r uct i on pur poses, an adequat e suppl y of el ect r i c i t y, wat er , and sani t ar y f aci l i t i es. I nst al l and mai nt ai n necessar y suppl y connect i ons f or t hese ut i l i t i es, but onl y at l ocat i ons and i n a manner t hat may be appr oved by t he Cont r act i ng Of f i cer ' s r epr esent at i ve. Al l i nst al l at i ons must compl y wi t h al l appl i cabl e codes, st andar ds, and r equi r ement s. Bef or e f i nal accept ance, t empor ar y connect i ons, i nst al l ed by t he Cont r act or , must be r emoved i n a manner sat i sf act or y t o t he Cont r act i ng Of f i cer .

3. 2. 2 Sani t at i on

Pr ovi de and mai nt ai n wi t hi n t he const r uct i on ar ea mi ni mum f i el d- t ype sani t ar y f aci l i t i es i n accor dance wi t h EM 385- 1- 1 Sect i on 02. Locat e t he f aci l i t i es behi nd t he const r uct i on f ence or out of t he publ i c v i ew. Cl ean uni t s and empt y wast es at l east once a week or mor e f r equent l y i nt o a muni ci pal , di st r i ct , or st at i on sani t ar y sewage syst em, or r emove wast e t o a commer ci al f aci l i t y . Obt ai n appr oval f r om t he syst em owner pr i or t o di schar ge i nt o a muni ci pal , di st r i ct , or commer ci al sani t ar y sewer syst em. Penal t i es or f i nes associ at ed wi t h i mpr oper di schar ge wi l l be t he r esponsi bi l i t y of t he Cont r act or . Coor di nat e wi t h t he Cont r act i ng Of f i cer and f ol l ow st at i on r egul at i ons and pr ocedur es when di schar gi ng i nt o t he st at i on sani t ar y sewer syst em. Mai nt ai n t hese conveni ences at al l t i mes.

I ncl ude pr ovi s i ons f or pest cont r ol and el i mi nat i on of odor s. Gover nment t oi l et f aci l i t i es wi l l not be avai l abl e t o Cont r act or ' s per sonnel .

3. 2. 3 Tel ephone

Make ar r angement s and pay al l cost s f or t el ephone f aci l i t i es desi r ed.

3. 2. 4 Fi r e Pr ot ect i on

Pr ovi de t empor ar y f i r e pr ot ect i on equi pment f or t he pr ot ect i on of per sonnel and pr oper t y dur i ng const r uct i on. Remove debr i s and f l ammabl e mat er i al s dai l y t o mi ni mi ze pot ent i al hazar ds.

3. 3 TRAFFI C PROVI SI ONS

3. 3. 1 Mai nt enance of Tr af f i c

a. Conduct oper at i ons i n a manner t hat wi l l not c l ose a t hor oughf ar e or i nt er f er e wi t h t r af f i c on r ai l ways or hi ghways except wi t h wr i t t en

SECTI ON 01 50 00 Page 7 per mi ssi on of t he Cont r act i ng Of f i cer at l east 15 cal endar days pr i or t o t he pr oposed modi f i cat i on dat e, and pr ovi de a Tr af f i c Cont r ol Pl an f or Gover nment appr oval det ai l i ng t he pr oposed cont r ol s t o t r af f i c movement f or appr oval . The pl an must be i n accor dance wi t h St at e and l ocal r egul at i ons and t he MUTCD, Par t VI . [ Make al l not i f i cat i ons and obt ai n al l per mi t s r equi r ed f or modi f i cat i on t o t r af f i c movement s out si de St at i on' s j ur i sdi ct i on. ] . Cont r act or may move over si zed and sl ow- movi ng vehi c l es t o t he wor ksi t e pr ovi ded r equi r ement s of t he hi ghway aut hor i t y have been met .

b. Conduct wor k so as t o mi ni mi ze obst r uct i on of t r af f i c , and mai nt ai n t r af f i c on at l east hal f of t he r oadway wi dt h at al l t i mes. Obt ai n appr oval f r om t he Cont r act i ng Of f i cer pr i or t o st ar t i ng any act i v i t y t hat wi l l obst r uct t r af f i c .

c. Pr ovi de, er ect , and mai nt ai n, at Cont r act or ' s expense, l i ght s, bar r i er s, s i gnal s, passageways, det our s, and ot her i t ems, t hat may be r equi r ed by t he Li f e Saf et y Si gnage, over head pr ot ect i on aut hor i t y havi ng j ur i sdi ct i on.

d. Pr ovi de cones, s i gns, bar r i cades, l i ght s, or ot her t r af f i c cont r ol devi ces and per sonnel r equi r ed t o cont r ol t r af f i c . Do not use f oi l - backed mat er i al f or t empor ar y pavement mar ki ng because of i t s pot ent i al t o conduct el ect r i c i t y dur i ng acci dent s i nvol v i ng downed power l i nes.

3. 3. 2 Pr ot ect i on of Tr af f i c

Mai nt ai n and pr ot ect t r af f i c on al l af f ect ed r oads dur i ng t he const r uct i on per i od except as ot her wi se speci f i cal l y di r ect ed by t he Cont r act i ng Of f i cer . Measur es f or t he pr ot ect i on and di ver si on of t r af f i c , i ncl udi ng t he pr ovi s i on of wat chmen and f l agmen, er ect i on of bar r i cades, pl aci ng of l i ght s ar ound and i n f r ont of equi pment t he wor k, and t he er ect i on and mai nt enance of adequat e war ni ng, danger , and di r ect i on s i gns, wi l l be as r equi r ed by t he St at e and l ocal aut hor i t i es havi ng j ur i sdi ct i on. Pr ovi de sel f - i l l umi nat ed ( l i ght ed) bar r i cades dur i ng hour s of dar kness.

Br i ght l y- col or ed ( or ange) vest s ar e r equi r ed f or al l per sonnel wor ki ng i n r oadways. Pr ot ect t he t r avel i ng publ i c f r om damage t o per son and pr oper t y. Mi ni mi ze t he i nt er f er ence wi t h publ i c t r af f i c on r oads sel ect ed f or haul i ng mat er i al t o and f r om t he si t e. I nvest i gat e t he adequacy of exi st i ng r oads and t hei r al l owabl e l oad l i mi t . Cont r act or i s r esponsi bl e f or t he r epai r of damage t o r oads caused by const r uct i on oper at i ons.

3. 3. 3 Rush Hour Rest r i ct i ons

Do not i nt er f er e wi t h t he peak t r af f i c f l ows pr ecedi ng and dur i ng nor mal oper at i ons wi t hout not i f i cat i on t o and appr oval by t he Cont r act i ng Of f i cer .

3. 3. 4 Dust Cont r ol

Dust cont r ol met hods and pr ocedur es must be appr oved by t he Cont r act i ng Of f i cer . Coor di nat e dust cont r ol met hods wi t h 01 57 19 TEMPORARY

ENVI RONMENTAL CONTROLS.

3. 4 REDUCED PRESSURE BACKFLOW PREVENTERS

Pr ovi de an appr oved r educed pr essur e backf l ow pr event i on assembl y at each l ocat i on wher e t he Cont r act or t aps i nt o t he Gover nment pot abl e wat er

SECTI ON 01 50 00 Page 8 suppl y.

Per f or m backf l ow pr event er t est s usi ng t est equi pment , pr ocedur es, and cer t i f i cat i on f or ms conf or mi ng t o t hose out l i ned i n t he l at est edi t i on of t he Manual of Cr oss- Connect i on Cont r ol publ i shed by t he FCCCHR Manual .

Test and t ag each r educed pr essur e backf l ow pr event er upon i ni t i al i nst al l at i on ( pr i or t o cont i nued wat er use) and quar t er l y t her eaf t er . Tag must cont ai n t he f ol l owi ng i nf or mat i on: make, model , ser i al number , dat es of t est s, r esul t s, mai nt enance per f or med, and si gnat ur e of t est er .

Recor d t est r esul t s on cer t i f i cat i on f or ms conf or mi ng t o r equi r ement s c i t ed ear l i er i n t hi s par agr aph. Af t er i nst al l at i on, NAVFAC Hawai i Wat er Ut i l i t i es wi l l t est and cer t i f y backf l ow pr event er . I f t he t empor ar y wat er connect i on needs t o be moved t o anot her l ocat i on dur i ng const r uct i on, t he Cont r act or must not i f y t he Cont r act i ng Of f i cer i n wr i t i ng a mi ni mum of 5 wor ki ng days pr i or t o movement . The r el ocat ed backf l ow pr event er wi l l be r e- t est ed and r e- cer t i f i ed by NAVFAC Hawai i Wat er Ut i l i t i es.

3. 5 CONTRACTOR' S TEMPORARY FACI LI TI ES

Cont r act or - owned or - l eased t r ai l er s must be i dent i f i ed by Gover nment assi gned number s. Appl y t he number t o t he t r ai l er wi t hi n 14 cal endar days of not i f i cat i on, or sooner , i f di r ect ed by t he Gover nment . Tempor ar y f aci l i t i es must meet r equi r ement s as i dent i f i ed i n EM 385- 1- 1 Sect i on 04.

Cont r act or i s r esponsi bl e f or secur i t y of t hei r pr oper t y. Pr ovi de adequat e out si de secur i t y l i ght i ng at t he t empor ar y f aci l i t i es. Tr ai l er s must be anchor ed t o r esi st hi gh wi nds and meet appl i cabl e st at e or l ocal st andar ds f or anchor i ng mobi l e t r ai l er s. Coor di nat e anchor i ng wi t h EM 385- 1- 1 Sect i on 04. The Cont r act Cl ause ent i t l ed " FAR 52. 236- 10, Oper at i ons and St or age Ar eas" and t he f ol l owi ng appl y:

3. 5. 1 Admi ni st r at i ve Fi el d Of f i ces

Pr ovi de and mai nt ai n admi ni st r at i ve f i el d of f i ce f aci l i t i es wi t hi n t he const r uct i on ar ea at t he desi gnat ed si t e. Gover nment of f i ce and war ehouse f aci l i t i es wi l l not be avai l abl e t o t he Cont r act or ' s per sonnel .

3. 5. 2 St or age Ar ea

Const r uct a t empor ar y 6 f oot hi gh chai n l i nk f ence ar ound t r ai l er s and mat er i al s. I ncl ude pl ast i c st r i p i nser t s, col or ed br own, so t hat v i s i bi l i t y t hr ough t he f ence i s obst r uct ed. Fence post s may be dr i ven, i n l i eu of concr et e bases, wher e soi l condi t i ons per mi t . Do not pl ace or st or e t r ai l er s, mat er i al s, or equi pment out si de t he f enced ar ea unl ess such t r ai l er s, mat er i al s, or equi pment ar e assi gned a separ at e and di st i nct st or age ar ea by t he Cont r act i ng Of f i cer away f r om t he vi c i ni t y of t he const r uct i on s i t e but wi t hi n t he i nst al l at i on boundar i es. Tr ai l er s, equi pment , or mat er i al s must not be open t o publ i c v i ew wi t h t he except i on of t hose i t ems whi ch ar e i n suppor t of ongoi ng wor k on t he cur r ent day.

Do not st ockpi l e mat er i al s out si de t he f ence i n pr epar at i on f or t he next day' s wor k. Par k mobi l e equi pment , such as t r act or s, wheel ed l i f t i ng equi pment , cr anes, t r ucks, and l i ke equi pment wi t hi n t he f enced ar ea at t he end of each wor k day.

Keep f enci ng i n a st at e of good r epai r and pr oper al i gnment . I f t he Cont r act or el ect s t o t r aver se gr assed or unpaved ar eas whi ch ar e not

SECTI ON 01 50 00 Page 9 est abl i shed r oadways wi t h const r uct i on equi pment or ot her vehi c l es, cover t he gr assed or unpaved ar eas wi t h a l ayer of gr avel as necessar y t o pr event r ut t i ng and t he t r acki ng of mud ont o paved or est abl i shed r oadways; gr avel gr adat i on must be at t he Cont r act or ' s di scr et i on. . Mow and mai nt ai n gr ass l ocat ed wi t hi n t he boundar i es of t he const r uct i on s i t e f or t he dur at i on of t he pr oj ect . Gr ass and veget at i on al ong f ences, st r uct ur es, under t r ai l er s, and i n ar eas not accessi bl e t o mower s must be edged or t r i mmed neat l y.

3. 5. 3 Suppl ement al St or age Ar ea

Upon r equest , and pendi ng avai l abi l i t y , t he Cont r act i ng Of f i cer wi l l desi gnat e anot her or suppl ement al ar ea f or t he use and st or age of t r ai l er s, equi pment , and mat er i al s. Thi s ar ea may not be i n c l ose pr oxi mi t y of t he const r uct i on s i t e but wi l l be wi t hi n t he i nst al l at i on boundar i es. Mai nt ai n t he ar ea i n a c l ean and or der l y f ashi on and secur ed i f needed t o pr ot ect suppl i es and equi pment . Ut i l i t i es wi l l not be pr ovi ded t o t hi s ar ea by t he Gover nment .

3. 5. 4 Appear ance of Tr ai l er s

a. Tr ai l er s must be r oadwor t hy and compl y wi t h al l appr opr i at e st at e and l ocal vehi c l e r equi r ement s. Tr ai l er s whi ch ar e r ust ed, have peel i ng pai nt or ar e ot her wi se i n need of r epai r wi l l not be al l owed on I nst al l at i on pr oper t y. Tr ai l er s must pr esent a c l ean and neat ext er i or appear ance and be i n a st at e of good r epai r .

b. Mai nt ai n t he t empor ar y f aci l i t i es. Fai l ur e t o do so wi l l be suf f i c i ent r eason t o r equi r e t hei r r emoval at t he Cont r act or ' s expense.

3. 5. 5 Tr ai l er s or St or age Bui l di ngs

a. Tr ai l er s or st or age bui l di ngs wi l l be per mi t t ed, wher e space i s avai l abl e, subj ect t o t he appr oval of t he Cont r act i ng Of f i cer .

b. Mount a s i gn not smal l er t han 24 by 24 i nches on t he t r ai l er or bui l di ng t hat shows t he company name, busi ness phone number , emer gency phone number and conf or ms t o t he f ol l owi ng r equi r ement s and sket ch:

Gr aphi c panel Al umi num, pai nt ed bl ue

Copy Scr een pai nt ed or v i nyl di e- cut , whi t e

Typef ace Uni ver s 65 u/ l c

See Sket ch No. 01500 ( gr aphi c) .

3. 5. 6 Saf et y Syst ems

Pr ot ect t he i nt egr i t y of al l i nst al l ed saf et y syst ems or per sonnel saf et y devi ces. Obt ai n pr i or appr oval f r om t he Cont r act i ng Of f i cer i f ent r ance i nt o syst ems ser vi ng saf et y devi ces i s r equi r ed. I f i t i s t empor ar i l y necessar y t o r emove or di sabl e per sonnel saf et y devi ces i n or der t o accompl i sh Cont r act r equi r ement s, pr ovi de al t er nat i ve means of pr ot ect i on pr i or t o r emovi ng or di sabl i ng any per manent l y i nst al l ed saf et y devi ces or equi pment and obt ai n appr oval f r om t he Cont r act i ng Of f i cer .

SECTI ON 01 50 00 Page 10

3. 5. 7 Weat her Pr ot ect i on of Tempor ar y Faci l i t i es and St or ed Mat er i al s

Take necessar y pr ecaut i ons t o ensur e t hat r oof openi ngs and ot her cr i t i cal openi ngs i n t he bui l di ng ar e moni t or ed car ef ul l y. Take i mmedi at e act i ons r equi r ed t o seal of f such openi ngs when r ai n or ot her det r i ment al weat her i s i mmi nent , and at t he end of each wor kday. Ensur e t hat t he openi ngs ar e compl et el y seal ed of f t o pr ot ect mat er i al s and equi pment i n t he bui l di ng f r om damage.

3. 5. 7. 1 Bui l di ng and Si t e St or m Pr ot ect i on

When a war ni ng of gal e f or ce wi nds i s i ssued, t ake pr ecaut i ons t o mi ni mi ze danger t o per sons, and pr ot ect t he wor k and near by Gover nment pr oper t y.

Pr ecaut i ons must i ncl ude, but ar e not l i mi t ed t o, c l osi ng openi ngs;

r emovi ng l oose mat er i al s, t ool s and equi pment f r om exposed l ocat i ons; and r emovi ng or secur i ng scaf f ol di ng and ot her t empor ar y wor k. Cl ose openi ngs i n t he wor k when st or ms of l esser i nt ensi t y pose a t hr eat t o t he wor k or any near by Gover nment pr oper t y.

3. 6 GOVERNMENT FI ELD OFFI CE

3. 6. 1 GOVERNMENT FI ELD OFFI CE

3. 6. 1. 1 Resi dent Engi neer ' s Of f i ce

a. The Cont r act or shal l f ur ni sh, pr i or t o t he st ar t of wor k, a l ockabl e ADA compl i ant f i el d of f i ce and equi pment f or t he use of t he Cont r act i ng Of f i cer .

b. A l eased ADA commer ci al of f i ce space i s accept abl e as t he f i el d of f i ce.

c. The of f i ce shal l be l ocat ed i n c l ose pr oxi mi t y t o t he pr oj ect s i t e as di r ect ed by t he Cont r act i ng Of f i cer .

d. Two har d copy set s each of t he Conf or med Pl ans ( f ul l s i ze ANSI D and hal f s i ze) and Speci f i cat i ons.

e. A separ at e Resi dent Engi neer ' s of f i ce must be pr ovi ded and mai nt ai ned f or t he Downt own Mont auk wor k, i f t he opt i on i s exer ci sed. Gover nment of f i ce and war ehouse f aci l i t i es ar e not avai l abl e t o t he Cont r act or ' s per sonnel .

f . The f ol l owi ng shal l be submi t t ed f or appr oval :

Equi pment and Ser vi ces:

No separ at e payment shal l be made f or pr ovi di ng t he i t ems bel ow and al l cost s i n connect i on t her ewi t h wi l l be consi der ed t he obl i gat i on of t he Cont r act or .

1. Of f i ce Space shal l be a mi ni mum of 1, 000 SF, wi t h l ockabl e i nt er i or door s. The space ( i f r ent ed i n a bui l di ng) shal l be i n good condi t i on. The of f i ce shal l cont ai n at l east t wo oper abl e wi ndows wi t h scr eens.

2. Two ( 2) encl osed bat hr ooms wi t h hot and col d wat er .

3. One ( 1) encl osed of f i ce of mi ni mum di mensi ons of 12 f eet x 12 f eet .

SECTI ON 01 50 00 Page 11

4. Par t i t i oned open f l at ar ea t o accommodat e one ( 1) of f i ce cubi c l es and meet i ng ar ea havi ng a mi ni mum of 700 SF.

5. Four ( 4) of f i ce desks wi t h l ockabl e dr awer s ( 60 i nches x 30 i nches) l ami nat ed t op and hi gh- back cl ot h swi vel chai r s.

6. Four ( 4) f i r e- pr oof , 4- dr awer , l egal - s i ze l ockabl e f i l i ng cabi net s.

7. Two ( 2) shel f set s, f our - shel ves hi gh x 12 i nches deep x 3 f eet l ong ( at t achabl e t o wal l ) .

8. One ( 1) 21" Col or TV wi t h basi c cabl e ser vi ce wi t h t he Weat her Channel i ncl uded.

9. Wal l TV swi vel mount wi t h out l et sur ge pr ot ect or .

10. Thr ee ( 3) of f i ce conf er ence t abl es, 2- 1/ 2 f eet by 8 f eet wi t h l ami nat ed t op conf i gur at i on.

11. Ei ght ( 8) st r ai ght hi gh back of f i ce chai r s wi t h wheel s.

12. Four ( 4) f ol di ng chai r s wi t h c l ot h padded seat s.

13. One ( 1) bul l et i n boar d, 3 f eet x 5 f eet .

14. Four ( 4) wast ebasket s wi t h suppl y of bags.

16. One ( 1) ver t i cal f i l i ng pl an r ack f or t wel ve set s of E- si ze pl ans.

17. One ( 1) dr af t i ng t abl e f or E- si ze dr awi ngs and chai r .

18. Thr ee ( 3) of f i ce t abl es, 3 f eet x 8 f eet wi t h l ami nat ed t op.

19. Two ( 2) coat r acks.

20. One ( 1) paper t owel di spenser wi t h t owel s. ( r esuppl y as needed)

21. One ( 1) paper cup di spenser wi t h cups. ( r esuppl y as needed)

22. One ( 1) wat er cool er / heat er wi t h wat er . ( r esuppl y as needed)

23. Toi l et f aci l i t i es as speci f i ed.

24. One ( 1) st eel l ocki ng st or age cabi net .

26. Al l st r uct ur es i nst al l ed under t hi s par agr aph FI ELD OFFI CE shal l be pr ovi ded wi t h, as a mi ni mum, t he f ol l owi ng ser vi ces:

a. Li ght i ng: el ect r i c l i ght , non- gl ar e t ypes l umi nar i es t o pr ovi de a mi ni mum i l l umi nat i on l evel of 50- f oot candl es at desk hei ght l evel .

b. Heat i ng and Cool i ng: adequat e equi pment t o mai nt ai n an ambi ent ai r t emper at ur e of 70 degr ees F +/ - 3 degr ees.

c. Wi ndow bl i nds.

d. Pot abl e bot t l ed wat er - Pr ovi de suf f i c i ent suppl y of bot t l ed 16. 9oz wat er f or f i el d of f i ce.

SECTI ON 01 50 00 Page 12

e. Fi r e Ext i ngui sher - Pr ovi de t wo : non- t oxi c, dr y chemi cal , f i r e ext i ngui sher s meet i ng Under wr i t er s Labor at or i es, I nc. appr oval f or Cl ass A, Cl ass B and Cl ass C f i r es wi t h a mi ni mum r at i ng of 10A;

20B, 10C.

f . For each bat hr oom: power - vent i l at ed, heat ed and compl yi ng wi t h appl i cabl e sani t ar y codes i ncl udi ng hot and col d r unni ng wat er and f l ush- t ype t oi l et .

g. 24- hour el ect r oni c secur i t y al ar m syst em wi t h di r ect f eed t o l ocal pol i ce.

h. DSL or Cabl e Modem Ser vi ce: Busi ness DSL or cabl e modem ser vi ce wi t h al l r equi r ed equi pment ( modems, f i l t er s, Et her net NI C car ds, et c. ) shal l be pr ovi ded f or t he ent i r e dur at i on of t he cont r act .

DSL ser vi ce shal l be 1500 Mbps downl oad/ 100 Mbps upl oad speed.

Ser vi ce shal l ut i l i ze a St at i c I P addr ess f or t he connect i on.

Cont r act or shal l pay al l cost s associ at ed wi t h t hi s ser vi ce i ncl udi ng I SP f ees. DSL or Cabl e Modem ser vi ce shal l be a ' dedi cat ed' ser vi ce, and t hi s l i ne shal l not be shar ed wi t h ot her User s ( i . e. , Cont r act or s Fi el d Of f i ce Tr ai l er and USACE Fi el d Of f i ce Tr ai l er shal l not ut i l i ze t he same DSL or Cabl e Modem l i ne v i a an Et her net Swi t ch/ Hub) . The Cont r act or shal l pr ovi de and i nst al l al l r equi r ed equi pment ( i . e. , Swi t ch, Hub, Et her net NI C Car ds, modems, et c. ) f or use wi t h Gover nment - f ur ni shed f i el d of f i ce comput er s.

i . I f cont r act or ut i l i zes VHF or s i mi l ar r adi o communi cat i on, pr ovi de base st at i on and t wo ( 2) por t abl e uni t s on t he Cont r act or ' s f r equency, al l wi t h desk char ger s.

j . The cont r act or shal l be r esponsi bl e f or t he mont hl y ut i l i t y and t el ephone payment and i nst al l at i on cost of t he above ser vi ce and equi pment .

k. The Cont r act or shal l pr ovi de l and l i ne wi t h a conf er ence phone si mi l ar t o Pol ycom Voi ceSt at i on 100 at hi s own expense.

l . The Cont r act or shal l pr ovi de Bl uet oot h compat i bl e speaker s f or use dur i ng al l meet i ngs and conf er ence cal l s.

m. Jani t or i al ser vi ces on a dai l y basi s i ncl udi ng, but not l i mi t ed t o, sweepi ng, empt yi ng basket s, weekl y moppi ng, dust i ng al l sur f aces, ser vi c i ng of t oi l et s and washi ng and waxi ng f l oor s, c l eani ng al l wi ndows ( i nsi de and out ) and r e- suppl y of paper goods and soap.

n. Snow and i ce r emoval i n t he v i c i ni t y of t he f i el d of f i ce may be r equi r ed dur i ng and af t er st or m event s.

27. Suf f i c i ent suppl y of el ect r i cal out l et s meet i ng NEC code f or r esi dent i al const r uct i on.

28. Fi r st Ai d Ki t : Pr ovi de t wo ( 2) k i t s. As a mi ni mum, each k i t shal l i ncl ude ant i sept i c k i t , eyewash sol ut i on, bandages, i nsect st i ng medi cat i on, aspi r i n and acet ami nophen, and col d pack, and at t he mi ni mum shal l conf or m t o ANSI Z308. 1 and USACE EM 385- 1- 1.

29. The f i el d of f i ce shal l be r emoved f r om t he pr oj ect s i t e when and as di r ect ed by t he Cont r act i ng Of f i cer . Secur e t he t r ai l er compl ex by an

SECTI ON 01 50 00 Page 13

8- f oot hi gh chai n l i nk f ence t opped by 3 r ows of bar b wi r e. The secur ed ar ea shal l be abl e t o accommodat e at l east 15 vehi c l es.

Pr ovi de a l ockabl e gat e wi t h t he f ence and secur i t y l i ght i ng i n t he t r ai l er compl ex.

30. Pr ovi de mi ni mum one ( 1) Combi nat i on Smoke/ Car bon Monoxi de Al ar m wi t h bat t er y back- up. Addi t i onal t o be pr ovi ded as needed f or adequat e cover age of of f i ce spaces.

31. Pr ovi de 2 ut i l i t y vehi c l e t ype, seven- passenger wi t h 4- wheel dr i ve not mor e t han 3 year s ol d ( mi ni mum 6 passenger s) f or Gover nment ' s use.

Mai nt enance of t he vehi c l es i ncl udi ng al l f uel , St at e i nspect i ons, and r equi r ed i nsur ance shal l be t he Cont r act or ' s r esponsi bi l i t y .

32. Pr i nt er : Pr ovi de t wo ( 2) Laser Jet Mul t i f unct i on Pr i nt er s 10, 000 sheet s of 8- 1/ 2 x 11 l aser - t ype pr i nt paper . Must have at mi ni mum 2 Hi - Speed USB 2. 0 Host ; 1 Hi - Speed USB 2. 0 Devi ce; 1Et her net 10/ 100 Base- TX net wor k; 1 RJ- 11 modem por t ; 802. 11 b/ g/ n St at i on; 802. 11 b/ g Access Poi nt . Repl acement i nk Car t r i dges shal l be suppl i ed as needed.

33. Di gi t al Camer a: Di gi t al Camer a: t wo ( 2) Bl ack 12 MP 4X Opt i cal Zoom Wat er pr oof Shockpr oof Wi de Angl e Di gi t al Camer a HDTV Out put , 028 t o 105 zoom compact wi t h pr opr i et y sof t war e est abl i shed t o be l egal cour t document s wi t h case, spar e bat t er y and memor y car d, comput er i nt er f ace and pr ogr am and desk char ger . I t i s necessar y t o have one ( 1) camer a per f i el d of f i ce.

34. Copi er : One heavy dut y, di gi t al dr y pr ocess phot ocopyi ng machi ne, wi t h aut o document f eeder , sor t er , col l at or , enl ar gi ng/ r educt i on abi l i t y , 8. 5 x 11, 8. 5 x 14 and 11 x 17 paper t r ays and adequat e suppl y of copy paper and pr i nt i ng suppl i es. The suppl y of copy paper shal l be r epl eni shed by t he Cont r act or r egul ar l y as r equi r ed by t he Cont r act i ng Of f i cer .

35. Fax Machi ne: One pl ai n paper f ax machi ne wi t h a dedi cat ed t el ephone l i ne and an adequat e suppl y of paper . The Cont r act or shal l r epl eni sh t he suppl y of f ax paper , weekl y as r equi r ed by t he Cont r act i ng Of f i cer .

36. Tel ephone: Two t el ephones: one f or phone ser vi ce and one f or f ax ser vi ce. Tel ephone shal l be t wo l i nes wi t h t went y number memor i es.

Phone ser vi ce shal l be appl i ed i n t he Cont r act or ' s name and i t emi zed bi l l s pai d by t he Cont r act or . Tel ephone ser vi ce shal l be pr ovi ded by " l andl i ne" t o t he of f i ce space. I nst al l at i on and phone company f ees shal l be pai d by t he Cont r act or . The Cont r act or shal l ar r ange f or t he t el ephone ser vi ce and i nst r ument as f ol l ows:

a. Two l i nes wi t h f our i nst r ument s, f i ve j acks, f or voi ce communi cat i on and i nt er com.

b. One l i ne dedi cat ed f or use by f ax machi nes.

c. One l i ne dedi cat ed f or use by t wo comput er modems.

d. One TCI P modem l i ne f or t he net wor k comput er .

37. Tel ephone Answer i ng Machi ne: One 2- l i ne di gi t al t el ephone answer i ng machi ne wi t h r emot e answer i ng and access capabi l i t y and voi ce t i me/ day st amp.

38. Rechar geabl e Fl ashl i ght Syst ems: Four ( 4) heavy- dut y Rechar geabl e f l ashl i ght s, char gi ng cr adl e, r echar geabl e Ni MH bat t er y ( or equi val ent ) , 12 vol t adapt er , and 120 vol t A/ C conver t er wi t h a

SECTI ON 01 50 00 Page 14 mi ni mum out put of 240 Lumens.

39. a. One 1200 Wat t s Count er t op Mi cr owave wi t h sensor cook

b. One 8 cup dr i p cof f ee Maker wi t h K- Cup wi t h St ai nl ess st eel Car af e

c. One St andar d s i ze Fr i dge wi t h mi n 5 cu. f t , St ai nl ess l ook

40. One beach dr i v i ng vehi c l e wi t h c l osed encl osur e wi t h USACE pl acar d.

Speci f i cat i on:

1. Engi ne: 4 cycl e, i ndust r i al gr ade

2. Hor sepower : 20. 1 hp r at ed at 3400 RPM

3. Fuel Capaci t y: 6. 5 Gal

4. Dr i vet r ai n: aut omat i c 4x4

3. 6. 2 Tr ai l er - Type Mobi l e Of f i ce

The opt i on i s avai l abl e t o, f ur ni sh and mai nt ai n a t r ai l er - t ype mobi l e of f i ce accept abl e t o t he Cont r act i ng Of f i cer t o meet t he r equi r ement s of t he mi ni mum f aci l i t i es speci f i ed above. Secur el y anchor t he t r ai l er t o t he gr ound at al l f our cor ner s t o guar d agai nst movement dur i ng hi gh wi nds. Coor di nat e r equi r ement s f or pr oper anchor i ng wi t h EM 385- 1- 1 Sect i on 04.

3. 7 PLANT COMMUNI CATI ONS

Whenever t he i ndi v i dual el ement s of t he pl ant ar e l ocat ed so t hat oper at i on by nor mal voi ce bet ween t hese el ement s i s not sat i sf act or y, i nst al l a sat i sf act or y means of communi cat i on, such as t el ephone or ot her sui t abl e devi ces and make avai l abl e f or use by Gover nment per sonnel .

3. 8 TEMPORARY PROJECT SAFETY FENCI NG

As soon as pr act i cabl e, but not l at er t han 15 days af t er t he dat e est abl i shed f or commencement of wor k, f ur ni sh and er ect t empor ar y pr oj ect saf et y f enci ng at t he wor k s i t e. Mai nt ai n t he saf et y f enci ng dur i ng t he l i f e of t he Cont r act and, upon compl et i on and accept ance of t he wor k, r emove f r om t he wor k s i t e.

3. 9 CLEANUP

Remove const r uct i on debr i s, wast e mat er i al s, packagi ng mat er i al and t he l i ke f r om t he wor k s i t e dai l y. Any di r t or mud whi ch i s t r acked ont o paved or sur f aced r oadways must be cl eaned away. St or e al l sal vageabl e mat er i al s r esul t i ng f r om demol i t i on act i v i t i es wi t hi n t he f enced ar ea descr i bed above or at t he suppl ement al st or age ar ea. Neat l y st ack st or ed mat er i al s not i n t r ai l er s, whet her new or sal vaged.

3. 10 RESTORATI ON OF STORAGE AREA

Upon compl et i on of t he pr oj ect r emove t he bul l et i n boar d, s i gns, bar r i cades, haul r oads, and al l ot her t empor ar y pr oduct s f r om t he si t e.

Af t er r emoval of t r ai l er s, mat er i al s, and equi pment f r om wi t hi n t he f enced ar ea, r emove t he f ence. Rest or e ar eas used dur i ng t he per f or mance of t he Cont r act t o t he or i gi nal or bet t er condi t i on. Remove gr avel used t o t r aver se gr assed ar eas and r est or e t he ar ea t o i t s or i gi nal condi t i on, SECTI ON 01 50 00 Page 15 i ncl udi ng t op soi l and seedi ng as necessar y.

- - End of Sect i on - -

SECTI ON 01 50 00 Page 16

01 50 00 - TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 CONSTRUCTION SITE PLAN
1.4 BACKFLOW PREVENTERS CERTIFICATE
1.4.1 Backflow Tester Certificate
1.4.2 Backflow Prevention Training Certificate
1.5 DOD CONDITION OF READINESS COR
1.6 CYBERSECURITY DURING CONSTRUCTION
1.6.1 Contractor Computer Equipment
1.6.1.1 Operating System
1.6.1.2 Anti-Malware Software
1.6.1.3 Passwords and Passphrases
1.6.1.4 Contractor Computer Cybersecurity Compliance Statements
1.6.2 Temporary IP Networks
1.6.2.1 Network Boundaries and Connections
1.6.3 Government Access to Network
1.6.4 Temporary Wireless IP Networks
1.6.5 Passwords and Passphrases
1.6.6 Contractor Temporary Network Cybersecurity Compliance Statements
PART 2 PRODUCTS
2.1 TEMPORARY SIGNAGE
2.1.1 Bulletin Board
2.1.2 Project Identification Signs
2.1.3 Warning Signs
2.2 TEMPORARY TRAFFIC CONTROL
2.2.1 Haul Roads
2.2.2 Barricades
2.3 FENCING
2.3.1 Polyethylene Mesh Safety Fencing
2.3.2 Chain Link Panel Fencing
2.3.3 Post-Driven Chain Link Fencing
2.4 TEMPORARY WIRING
2.5 BACKFLOW PREVENTERS
PART 3 EXECUTION
3.1 EMPLOYEE PARKING
3.2 AVAILABILITY AND USE OF UTILITY SERVICES
3.2.1 Temporary Utilities
3.2.2 Sanitation
3.2.3 Telephone
3.2.4 Fire Protection
3.3 TRAFFIC PROVISIONS
3.3.1 Maintenance of Traffic
3.3.2 Protection of Traffic
3.3.3 Rush Hour Restrictions
3.3.4 Dust Control
3.4 REDUCED PRESSURE BACKFLOW PREVENTERS
3.5 CONTRACTOR'S TEMPORARY FACILITIES
3.5.1 Administrative Field Offices
3.5.2 Storage Area
3.5.3 Supplemental Storage Area
3.5.4 Appearance of Trailers
3.5.5 Trailers or Storage Buildings
3.5.6 Safety Systems
3.5.7 Weather Protection of Temporary Facilities and Stored Materials
3.5.7.1 Building and Site Storm Protection
3.6 GOVERNMENT FIELD OFFICE
3.6.1 GOVERNMENT FIELD OFFICE
3.6.1.1 Resident Engineer's Office

3.6.2 Trailer-Type Mobile Office

3.7 PLANT COMMUNICATIONS
3.8 TEMPORARY PROJECT SAFETY FENCING
3.9 CLEANUP
3.10 RESTORATION OF STORAGE AREA

File details come from the government source that posted it. Updated .