Pages from 125-156 123796_Full Binder_Phase 2 - V11.pdf

PDF 8 MB Posted

Attached to
Renovate & Repair – Building 20 Construction project at the Watervliet Arsenal, NY
Solicitation number
W912DS22B0025
Issued by

About this file

This pre-solicitation notice provides details for the renovation and repair of portions of Building 20 at the Watervliet Arsenal in New York. The U.S. Army Corps of Engineers District New York intends to complete hazardous material abatement, window, siding, and door replacements, accessibility renovations to restrooms and locker rooms, office renovations including associated HVAC and lighting, entrance replacements including ramps and vestibules, renovation of the west entrance stair hall and vestibule, and exterior masonry repairs. The estimated construction cost is between $10-25 million. The solicitation number is W912DS22B0025 and proposals are due in September 2022, with award projected for later that same month. The Watervliet Arsenal located in Watervliet, New York is the facility undergoing renovation.

View the file

Other files

File Type Posted
Bid Abstract_W912DS22B0025 BLG 20.pdf PDF
ATL No. CD4849E-01-07-20 Rev 1 Burns - Watervliet Ped Bridge.pdf PDF
09 90 00.pdf PDF
W912DS22B0025 Amend 0007.pdf PDF
ATL No CD4849E-02-07-22 Rev 1 - Burns - Watervliet HVAC Pad.pdf PDF
09 06 00.pdf PDF
RBM Survey Report Watervliet Arsenal NY - Bldg 20 Phase 2 V1 - Final.pdf PDF
Site Visit Sign in Sheet 2022-09-16.pdf PDF
123796 Phase II Final Design - Addendum 003 Project Specifications Binder.pdf PDF
W912DS22B0025 Amend 0006.pdf PDF
WVA Building 20 - Bid Option - Drawing Breakdown.pdf PDF
RBM Survey Report Watervliet Arsenal NY - Bldg 20 V1 - Final w Attachments.pdf PDF
SGH Bridge Crane Steel Inspection Report 052022.pdf PDF
W912DS22B0025 Amend 0005.pdf PDF
Bid bond form SF24-16e.pdf PDF
123796 Arch Addendum002 S and S 3.pdf PDF
123796 Phase II Final Design - Addendum 002 Project Specifications Binder.pdf PDF
123796 Arch Addendum002 S and S 2.pdf PDF
123796 Arch Addendum002 S and S 1.pdf PDF
W912DS22B0025 Amend 0004.pdf PDF
W912DS22B0025 Amend 0003.pdf PDF
Site Visit sign-in Sheet 30-Aug-2022.pdf PDF
123796 Phase II Final Design - Addendum 01 Specification Binder R1-1.pdf PDF
123796_Full Binder_P2_RTA_ADD 001_Revised - V2.pdf PDF
W912DS22B0025 Amend 0002.pdf PDF
W912DS22B0025 Amend 0001.pdf PDF
123796 Phase II 100 percent Final Design Specification Binder - R3.pdf PDF
Pages from 101-125 123796_Full Binder_Phase 2 - V11.pdf PDF
W912DS22B0025.pdf PDF
Pages 26-56 from 123796_Full Binder_Phase 2 100 - V11.pdf PDF
123796 Phase II 100_ Final Design Specification Binder - R3 (1).pdf PDF
Pages from 72-100 123796_Full Binder_Phase 2 100 - V11.pdf PDF
Pages from 257-277 123796_Full Binder_Phase 2 - V11.pdf PDF
Pages 1 to 25 from 123796 Full Binder Phase 2 V11.pdf PDF
Pages from 177-200 123796_Full Binder_Phase 2 - V11.pdf PDF
Pages from 200-225 123796_Full Binder_Phase 2 - V11.pdf PDF
Pages from 226-256 123796_Full Binder_Phase 2 - V11.pdf PDF
Pages from 277-300 123796_Full Binder_Phase 2 - V11.pdf PDF
Pages from 156-176 123796_Full Binder_Phase 2 - V11.pdf PDF
Pages from 57-72 123796_Full Binder_Phase 2 - V11.pdf PDF
Pages from 300-334 123796_Full Binder_Phase 2 - V11.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RIGID INSULATION CANT STRIP

PRE-FINISHED METAL

FLASHING W/ CONT. CLEAT

FASTENED TO TRANSLUCENT

PANEL FRAME

EXISTING STEEL

SUPPORT STRUCTURE

TO REMAIN

GRIND OUT EXISTING MORTAR

JOINT 1 1/2" AND INSTALL

FLASHING REGLET WITH BACK

ROD AND SEALANT IN JOINT

STEEL ANGLE WELDED IN

FIELD TO EXISTING.

RE: STRUC

BACK-FASTENED

TRANSLUCENT PANEL

SYSTEM

EXISTING STEEL

TO REMAIN

STRCUTURAL STEEL

RE: STRUCTURE

METAL SILL FLASHING

16 GA GALV. SHEET METAL

SUPPORT

BACKER ROD AND SEALANT

REFER TO D1/A-671 FOR DEMO NOTES

BACK-FASTENED

TRANSLUCENT PANEL SYSTEM

EXISTING L3X2X1/4

@ 4'-0" O.C. STEEL

TO REMAIN

STRUCTURAL STEEL

RE: STRUCTURE

PRE-FINISHED METAL FLASHING

WITH CONTINOUS CLEAT

FASTENED TO STOREFRONT

SYSTEM

BLOCKING/SHIM

ALUMINUM STOREFRONT

FRAMING

FILL VOID WITH MINERAL

WOOL INSULATION

CONTINUOUS JOINT

SEALANT, TYP. BOTH

SIDES

EXISITING STEEL

TO REMAIN

INSULATED METAL

PANEL SYSTEM, R-16

RIGID INSULATION

CANT STRIP

PRE-FINISHED METAL

FLASHING WITH CONT.

CLEAT FASTENED TO

METAL PANEL

INSULATED METAL

PANEL SYSTEM, R-16

STEEL ANGLE WELDED IN

FIELD TO EXISTING.

RE: STRUC

GRIND OUT EXISTING MORTAR

JOINT 1 1/2" AND INSTALL

FLASHING REGLET WITH BACK

ROD AND SEALANT IN JOINT

EXISTING L3X2X1/4

PANEL SUPPORT

(BOX) FRAMING TO

REMAIN

EXISTING

TRUSSWORK AND

SUPPORTS TO

REMAIN REMOVE EXISTING METAL

PANEL AND ASSOCIATED

COMPONENTS

EXISITNG

CONCRETE SIL

EXISTING L3X2X1/4 @

4'-0" O.C. STEEL TO

REMAIN

STRUCTURAL STEEL

RE: STRUCTURE

ALUM. FLASHING

REFER TO A1/A-671 FOR

DEMO NOTES

INSULATED GLASS

ALUMINUM

STOREFRONT FRAMING

BACKER ROD AND

SEALANT ON BOTH SIDES

2 1/16"

4"

EXISTING

CONCRETE SILL TO

REMAIN

REMOVE EXISTING

STEEL SASHED

WINDOWS

EXISTING L3X2X1/4

MULLIONS TO

REMAIN

REMOVE EXISTING

3X2X1/4 MULLION

BASE PLATE

REMOVE EXISTING 1 1/2 X

1 X 14 GA. STL. RECT.

TUBING

EXISTING L3X2X1/4

MULLION TO REMAIN

REMOVE EXISTING

MULLION CLOSURE

REMOVE EXISTING METAL

PANEL AND ASSOCIATED

COMPONENTS

REMOVE EXISTING

STEEL SASHED

WINDOWS

REMOVE EXISTING

ALUM. FLASHING

EXISTING L3X2X1/4

PANEL BASE

SUPPORT TO REMAIN

EXISTING L3X2X1/4

@ 4'-0" O.C. STEEL

TO REMAIN

STRUCTURAL STEEL

RE: STRUCTURE 18 GA. PRE-FINISHED METAL

FLASHING WITH CONTINOUS

CLEAT FASTENED TO

STOREFRONT SYSTEM

FILL VOID WITH MINERAL

WOOL INSULATION

CONTINUOUS JOINT

SEALANT

EXISITING STEEL

TO REMAIN

INSULATED METAL

PANEL SYSTEM, R-16

INSULATED METAL

PANEL SYSTEM, R-16

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

W D

S -1

-D

-0

/2

/2

:0

:3

P

M

A-671

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

S T

O R

E F

R O

N T

A N

D T

R A

N S

P A

R E

N T

P A

N E

L D

E T

A

IL

S

SCALE: 3" = 1'-0"F7

TRANSLUCENT WALL PANEL HEAD DETAIL

SCALE: 3" = 1'-0"D7

TRANSLUCENT WALL PANEL SILL

SCALE: 3" = 1'-0"C4

STOREFRONT HEAD DETAIL

SCALE: 3" = 1'-0"F4

IMP HEAD DETAIL

0 3" 6" 9"

0 3" 6" 9"

0 3" 6" 9"

0 3" 6" 9"

SCALE: 3" = 1'-0"F1

HEAD DETAIL - DEMO

0 3" 6" 9"

SCALE: 3" = 1'-0"A4

STOREFRONT SILL DETAIL

0 3" 6" 9"

SCALE: 3" = 1'-0"A1

STOREFRONT SILL - DEMO

0 3" 6" 9"

SCALE: 3" = 1'-0"C1

SILL DETAIL - DEMO

0 3" 6" 9"

REFER TO F1/A-671 FOR DEMO NOTES

SCALE: 3" = 1'-0"B7

IMP INFILL HEAD DETAIL

0 3" 6" 9"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

BACKER ROD AND

SEALANT ON BOTH

SIDES

ALUMINUM STOREFRONT

FRAMING

INSULATED METAL PANEL

SYSTEM, R-16

MISC. SUPPORT STEEL

RE: STRUC

BACKFASTENED TRANSLUCENT WALL

PANEL

INSULATED METAL PANEL

SYSTEM, R-16

MISC. SUPPORT STEEL

RE: STRUC

EXISTING

TRUSSWORK AND

SUPPORTS

EXISTING CHANNEL

SUPPORT

8 X 11.5

BACKER ROD AND SEALANT

BACKFASTENED TRANSLUCENT WALL

PANEL

INSULATED METAL PANEL

EXISTING ROOF MEMBRANE

EPDM FLASHING

PREFINISHED BASE FLASHING

CONTINUOUS JOINT SEALANT

TERM BAR

EXTERIOR GRADE

PLYWOOD

COMPRESSION TUBING

STRCUTURAL STEEL

RE: STRUCTURE

EXISITING STEEL TO

REMAIN

SEALANT

BREAK METAL

ALUMINUM STOREFRONT

FRAMING

EXISTING WALL

BLOCKING AS

REQUIRED

EXISITNG

CONCRETE SIL

3" X 2" X 1/4" MULLION BASE

PLATE LAGGED TO SILL W/

1/2" LAG BOLT & EXP. SHIELD

L 3 X 2 X 1/4 MULLIONS

EV. 4'-0" O.C.

1 1/2 X 1" X 14 GA. STL RECT.

TUBING W/ 1/4" LAGS AND

EXPAN. SHIELDS EV. 8" O.C.

STEEL TUBING

INSULATED METAL PANEL

ALUM. FLASHING

BLOCKING

EXISTING STEEL TO REMAIN

1/

2"

EXISTING

TRUSSWORK AND

SUPPORTS

EXISTING CHANNEL

SUPPORT

8 X 11.5

3" X 2" X 1/4" MULLION BASE

PLATE LAGGED TO SILL W/

1/2" LAG BOLT & EXP. SHIELD

L 3 X 2 X 1/4 MULLIONS

EV. 4'-0" O.C.

1 1/2 X 1" X 14 GA. STL RECT.

TUBING W/ 1/4" LAGS AND

EXPAN. SHIELDS EV. 8" O.C.

EXISTING

TRUSSWORK AND

SUPPORTS

EXISTING CHANNEL

SUPPORT

8 X 11.5 INSULATED METAL PANEL

PANEL CLIP

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

W D

S -1

-D

-0

/2

/2

:0

:3

P

M

A-672

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

S T

O R

E F

R O

N T

A N

D T

R A

N S

L U

C E

N T

P A

N E

L D

E T

A

IL

S

NTSSCALE:A1

STOREFRONT AT IMP JAMB

SCALE: 3" = 1'-0"A4

TRANSLUCENT WALL PANEL AT IMP JAMB

SCALE: 3" = 1'-0"E4

TWP SILL AND IMP HEAD DETAIL

0 3" 6" 9"

0 3" 6" 9"

SCALE: 3" = 1'-0"C8

STOREFRONT JAMB

0 3" 6" 9" 0 3" 6" 9"

SCALE: 3" = 1'-0"C1

IMP SILL

0 3" 6" 9"

0 3" 6" 9"0 3" 6" 9"

SCALE: 3" = 1'-0"C4

STOREFRONT JAMB - DEMO

SCALE: 3" = 1'-0"E1

IMP SILL AND HEAD DETAIL - DEMO

SCALE: 3" = 1'-0"E8

IMO SILL - DEMO

0 3" 6" 9"

SCALE: 3" = 1'-0"A8

IMP DETAIL

0 3" 6" 9"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

1' - 7"

1'

/2

1' - 3"

/2

INSULATED METAL PANEL

SYSTEM, R-16

EXISTING STEEL TO

REMAIN

ALUMINUM STOREFRONT

FRAMING

BACKER ROD AND

SEALANT ON BOTH

SIDES

ALUMINUM STOREFRONT

FRAMING

BACKER ROD AND

SEALANT ON BOTH

SIDES

MISC. SUPPORT STEEL

WELDED TO EXISTING STEEL

CONTINUOUS JOINT

SEALANT, TYPICAL

PREFINISHED SHEET

METAL CORNER

TRIM

CMFM SUPPORTS AT

SILL, MID SPAN, AND

HEAD

BACK FASTENED

TRANSLUCENT PANEL SYSTEM

EXISTING STEEL TO

REMAIN

MISC. STEEL TUBING

INSULATED METAL PANEL

SYSTEM, R-16

PRE-FINISHED

METAL CORNER

TRIM

EXISTING STEEL TO

REMAIN

CMFM SUPPORTS AT

SILL, MID SPAN, AND

HEAD

1'

INSULATED METAL PANEL

SYSTEM, R-16

EXISTING STEEL TO

REMAIN

BACKER ROD AND

SEALANT ON BOTH

SIDES

BACK FASTENED

TRANSLUCENT PANEL SYSTEM

MISC. SUPPORT

STEEL

1'

INSULATED METAL PANEL

SYSTEM, R-16

EXISTING STEEL TO

REMAIN

BACKER ROD AND

SEALANT ON BOTH

SIDES

ALUMINUM STOREFRONT

FRAMING

PREFINISHED SHEET METAL COVER

MINERAL WOOL INSULATION

PREFINISHED SHEET METAL COVER

PREFINISHED SHEET METAL

CORNER TRIM AND CONTINUOUS

JOINT SEALANT

1'

INSULATED METAL PANEL

SYSTEM, R-16

EXISTING STEEL TO

REMAIN

BACKER ROD AND

SEALANT ON BOTH

SIDES

OVERHEAD DOOR TRACK

PREFINISHED SHEET METAL COVER

MINERAL WOOL INSULATION

PREFINISHED SHEET METAL COVER

1' - 3"

/2

EXISTING STEEL TO

REMAIN, PREP

SURFACE TO RECEIVE

NEW WORK

EXISTING STEEL TO

REMAIN

EXISTING

TRUSSWORK AND

SUPPORTS

EXISTING CHANNEL

SUPPORT

8 X 11.5

BACKFASTENED TRANSLUCENT WALL

PANEL

MISC. SUPPORT STEEL

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

W D

S -1

-D

-0

/2

/2

:0

:3

P

M

A-673

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

S T

O R

E F

R O

N T

A N

D T

R A

N S

L U

C E

N T

P A

N E

L D

E T

A

IL

S

SCALE: 3" = 1'-0"E4

STOREFRONT JAMB

SCALE: 3" = 1'-0"E8

TRANSLUCENT WALL PANEL JAMB

SCALE: 3" = 1'-0"C1

INSULATED METAL PANEL JAMB

SCALE: 1 1/2" = 1'-0"A1

TRANSLUCENT PANEL JAMB - OVERHEAD DOOR

SCALE: 1 1/2" = 1'-0"C8

STOEFRONT JAMB - OVERHEAD DOOR

SCALE: 1 1/2" = 1'-0"A4

IMP JAMB - OVERHEAD DOOR

SCALE: 3" = 1'-0"E1

STOREFRONT JAMB - DEMO

0 3" 6" 9"

0 3" 6" 9"

0 3" 6" 9" 0 3" 6" 9"

SCALE: 1 1/2" = 1'-0"C4

STOREFRONT JAMB - OVERHEAD DOOR - DEMO

0 3" 6" 9"

0 3" 6" 9"

0 3" 6" 9"

0 3" 6" 9"

SCALE: 3" = 1'-0"A8

TRANSLUCENT PANEL DETAIL

0 3" 6" 9"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

GENERAL NOTES:

1. REFER TO SPECIFICATIONS FOR THE BASIS OF DESIGN OR

EQUIVALENT MANUFACTURER TECHNICAL REQUIREMENTS.

2. ALL ITEMS DENOTED WITH - IN SCHEDULE ARE EXISTING

MATERIALS TO REMAIN.

3. REFER TO INTERIOR ELEVATIONS, REFLECTED CEILING

DRAWINGS, FINISH DRAWINGS, ENLARGED PLAN

DRAWINGS AND INTERIOR DETAIL DRAWINGS FOR

ADDITIONAL FINISH PLACEMENT INFORMATION.

4. REFER TO ELECTRICAL DRAWINGS, MECHANICAL

DRAWINGS, STRUCTURAL DRAWINGS AND

COMMUNICATION DRAWINGS FOR COORDINATION OF

BUILDING FINISHES TO BUILDING SYSTEMS.

5. REFER TO FINISH DRAWINGS FOR PLACEMENT OF FLOOR

FINISHES, FLOOR PATTERNS AND FLOOR MATERIAL

CHANGES. REFER TO FLOORING TRANSITION DETAILS FOR

TRANSITIONS BETWEEN ADJOINING FLOORING MATERIALS,

WHERE APPLICABLE.

6. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR

WALL FINISH EXTENTS AND CORNER GUARD LOCATIONS.

7. REFER TO REFLECTED CEILING DRAWINGS FOR CEILING

HEIGHTS AND CEILING MATERIAL EXTENTS.

8. REFER TO ENLARGED TOILET DRAWINGS, FINISH PLANS

AND INTERIOR ELEVATIONS FOR PLACEMENT OF INTERIOR

FINISHES IN TOILET ROOMS.

9. REFER TO MILLWORK DETAIL DRAWINGS AND INTERIOR

ELEVATIONS FOR ASSIGNMENT OF SOLID SURFACE AND

PLASTIC LAMINATE FINISHES AND ADDITIONAL

INFORMATION.

10. PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL

MOUNTED ITEMS INCLUDING TOILET FIXTURES, TOILET

ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES,

COUNTERTOP SUPPORTS, FLAT PANEL DISPLAYS,

ACOUSTICAL WALL PANELS, AND ANY OTHER WALL

MOUNTED OBJECT.

11. ALL INTERIOR DOOR FRAMES TO BE (PA-3). SEMIGLOSS

FINISH.

12. ALL INTERIOR HOLLOW METAL DOORS AND INTERIOR FACE

OF EXTERIOR DOOR TO BE PAINT (PA-3). SEMI-GLOSS

FINISH.

13. INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH

COLOR.

14. WALL CORNER GUARDS TO BE INSTALLED STARTING AT

THE TOP OF THE SCHEDULED WALL BASE.

15. AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL

EXPOSED SURFACES.

16. MOISTURE RESISTANT GYPSUM BOARD SHALL BE USED IN

SOFFITS AND CEILINGS OF RESTROOMS, LOCKER ROOMS,

SHOWERS AND OTHER WET AREAS.

17. COORDINATE WITH MECHANICAL / ELECTRICAL FOR

FINISHES ON MECHANICAL OR ELECTRICAL EQUIPMENT.

18. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL

SURFACES, OPERATING PARTS, LABELS OR WARNINGS.

19. ALL JANITORS CLOSETS SHALL HAVE A MOP SINK AND

WALL MOUNTED METAL MOP/BROOM HOLDER WITH UTILITY

SHELF ABOVE.

20. ALL METAL FABRICATIONS AND HANDRAILS TO BE (PA-3).

21. ALL SWITCHPLATES AND OUTLET COVERS TO BE WHITE.

OUTLET COLOR TO COORDINATE WITH COVER COLOR.

22. MATCH FINISH OF COVERS FOR RETURN AIR DUCTS, VENTS

AND REGISTERS IN DRYWALL CEILINGS AND WALLS TO

ADJACENT SURFACE.

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

W D

S -1

-D

-0

/2

/2

:0

:3

P

M

A-701

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

R O

O M

F

IN

IS

H

L E

G E

N D

A N

D S

C H

E D

U L E

ROOM FINISH SCHEDULE

ROOM

NUMBER ROOM NAME FLOOR

WALLS

CEILING REMARKSBASE NORTH EAST SOUTH WEST

GROUND FLOOR

100 OFFICE - - - - - - -

100A SHOP / MANUFACTURING AREA EF-1 INT PE-1 PE-1 PE-1 PE-1 EXP/PE-2

100B CONNECTOR CORRIDOR - - - - - - -

100C VESTIBULE EF-1 INT PE-1 PE-1 PE-1 PE-1 EXP/PE-2

100D WASTE REMOVAL - - - - - - -

100E VESTIBULE - - PA-1 PA-1 PA-1 PA-1 EXP/PA-2 A

101 OFFICE RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

101A OFFICE RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

101B HALL RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

101C ALL GENDER EF-1 INT PE-1 PE-1 PE-1 PE-1 ACT-2

101D IT STORAGE - - - - - - -

102 SUPERVISOR'S OFFICE - - - - - - -

103 BREAK ROOM RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 -

103A BREAK ROOM HALL RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

104 WOMEN'S LOCKER ROOM EF-1 INT PE-1 PE-1 PE-1 PE-1 EXP/PE-2

104A WOMEN'S LATRINE EF-1 INT TLP-1 PE-1 TLP-1 PE-1 ACT-2

104B WOMEN'S LATRINE HALL EF-1 INT PE-1 PE-1 PE-1 PE-1 ACT-2

104C WOMEN'S LOCKER HALL EF-1 INT PE-1 PE-1 PE-1 PE-1 ACT-2

104D WOMEN'S SHOWER EF-1 INT PE-1 PE-1 PE-1 PE-1 GYP/PE-2

104E MOTHER'S ROOM

105A STAIR HALL - - PA-1 PA-1 PA-1 PA-1 ACT-1 A

106 MEN'S LATRINE EF-1 INT TLP-1 PE-1 TLP-1 PE-1 ACT-2

106A MEN'S LATRINE/LOCKER HALL EF-1 INT PE-1 PE-1 PE-1 PE-1 ACT-2

107 MEN'S LOCKER ROOM EF-1 INT PE-1 PE-1 PE-1 PE-1 EXP/PE-2

107A TOOL ROOM - - - - - - -

107B MEN'S SHOWER EF-1 INT PE-1 PE-1 PE-1 PE-1 GYP/PE-2

107C UTILITY ROOM - - - - - - -

108 TOOL ROOM - - - - - - -

109 PRESET

109D J.C. CS-1 RB-1 FRP-1 FRP-1 PA-1 PA-1 GYP/PA-2

ENTRY LOBBY

109A MID LEVEL ENTRY VESTIBULE - - PA-1 PA-1 PA-1 PA-1 ACT-1

109B MID LEVEL STAIR HALL - - PA-1 PA-1 PA-1 PA-1 ACT-1

SECOND FLOOR

200 PASSAGE EF-1 INT PE-1 PE-1 PE-1 PE-1 ACT-2

200A WOMEN'S LATRINE EF-1 INT TLP-1 PE-1 PE-1 TLP-1 ACT-2

200B MOTHER'S ROOM EF-1 INT PE-1 PE-1 PE-1 PE-1 EXP/PE-2

201 OPEN OFFICE - - - - - - -

201A ADMIN - - - - - - -

201B OFFICE - - - - - - -

201C OFFICE - - - - - - -

201D CONFERENCE - - - - - - -

201E VESTIBULE - - - - - - -

202 MEN'S LATRINE EF-1 INT TLP-1 PE-1 TLP-1 PE-1 ACT-2

202A J.C. CS-1 RB-1 FRP-1 FRP-1 PA-1 PA-1 GYP/PA-2

203 OPEN OFFICE - - - - - - -

203A CONFERENCE - - - - - - -

203B OFFICE - - - - - - -

203C OFFICE - - - - - - -

209 STAIR ENTRY - - PA-1 PA-1 PA-1 PA-1 ACT-1 A

ROOM FINISH LEGEND

BASIS OF DESIGN OR EQUIVALENT

MATERIAL DESCRIPTION MANUF.

PRODUCT

NAME/NUMBER

MODEL

NAME/NUMBER COLOR REMARKS

CEILING

ACT-1 ACOUSTICAL CELING TILE - 24" X 24" X

3/4" W/ PRELUDE XL15/16" WHITE GRID

ARMSTRONG ULTIMA 1912 WHITE -

ACT-2 ACOUSTICAL CELING TILE, CLEAN ROOM

- 24" X 24" x 3/4" W/ PRELUDE XL15/16"

WHITE GRID

ARMSTRONG ULTIMA HEALTH ZONE 1937 WHITE -

EXP EXPOSED CEILING - - - - -

GYP MOISTURE RESISTANT GYPSUM BOARD CEILING - - - - -

FLOORING

CS-1 CONCRETE - SEALED - - - - -

EF-1 EPOXY FLOORING STONHARD STONCLAD GS /

STONKOTE HT4

RF-1 RESILIENT FLOOR TILE, 9" X 36" PATCRAFT SURFACE TONE I464V 0601V PLATEAU 00575 -

GROUT

GR-1 TILE GROUT, EPOXY - WALLS MAPEI - - - -

MISCELLANEOUS

BH-1 HDPE BENCH ASI GLOBAL PARTITIONS - - - -

BH-2 ADA HDPE BENCH - 20" D X 42" W ASI GLOBAL PARTITIONS - - - -

CG-1 CORNERGUARD, VINYL - 3" LEG, FLUSH

MOUNTED

CONSTRUCTION SPECIALTIES - FS-20N - -

FRP-1 FIBERGLASS REINFORCED PANEL CONSTRUCTION SPECIALTIES ACROVYN 4000 - - -

LK-1 DOUBLE TIER HDPE LOCKERS ASI GLOBAL PARTITIONS PLASTIC TRADITIONAL

PLUS

MT-1 METAL TRIM - OUTSIDE WALL CORNER SCHLUTER - - - -

MT-2 METAL TRIM - TOP CAP SCHLUTER - - - -

TP-1 TOILET PARTITION / URINAL SCREENS ASI GLOBAL PARTITIONS - - - -

PAINT

PA-1 ACRYLIC/LATEX PAINT - FIELD - EGGSHELL/SATIN

FINISH

SHERWIN WILLIAMS - - - -

PA-2 ACRYLIC/LATEX PAINT - CEILING - FLAT FINISH SHERWIN WILLIAMS - - - -

PA-3 ACRYLIC/LATEX PAINT - TRIM - SEMI-GLOSS FINISH SHERWIN WILLIAMS - - - -

PE-1 EPOXY PAINT - FIELD - SATIN FINISH SHERWIN WILLIAMS - - - -

PE-2 EPOXY PAINT - CEILING - SATIN FINISH SHERWIN WILLIAMS - - - -

PLASTIC LAMINATE

PLAM-1 HIGH PRESSURE LAMINATE - CASEWORK WILSONART - - - -

SOLID SURFACE FABRICATION

SSF-1 SOLID SURFACE COUNTERTOPS, 1/2" THICK CORIAN - - - -

SSF-2 SOLID SURFACE SHOWER PANELS, 1/4" THICK INPRO CORP ENDURANT / BIOPRISM - - -

TLP-1 PORCELAIN WALL TILE, 12" X 24" CORIAN - - - -

WALL BASE

INT INTEGRAL COVE BASE, EPOXY FLOORING, 4"H STONHARD STONCLAD GS /

STONKOTE HT4

RB-1 RESILIENT WALL BASE, 4"H TARKETT PERCEPTIONS - - -

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

BREAK ROOM

SUPERVISOR'S

OFFICE

OFFICE

101A

OFFICE

WOMEN'S LOCKER

ROOM

WOMEN'S LATRINE

104A

WOMEN'S LATRINE

HALL

104B

WOMEN'S LOCKER

HALL

104C

BREAK ROOM HALL

103A

WOMEN'S SHOWER

104D

ALL GENDER

101C

HALL

101B

J.C.

109D

FRP-1

GENERAL NOTES:

1. REFER TO ROOM FINISH SCHEDULE AND FINISH LEGEND

FOR FLOOR FINISHES NOT INDICATED ON DRAWING.

2. REFER TO SHEET A-562 FOR FLOOR TRANSITION DETAILS.

3. FOR FLOORING MATERIAL TRANSITIONS WHICH OCCUR AT

DOORWAYS,TERMINATE FINISH TRANSITION AND

TRANSITION STRIP UNDER THE DOOR STOP OR CENTER

UNDER THE CLOSED DOOR.

4. CENTER ALL WALL TILE SO THAT PERIMETER CUTS ARE

EQUAL UNLESS NOTED OTHERWISE.

5. INSTALL WALL TILE IN ACCORDANCE WITH TCA W245 AND

SHOWER RECEPTOR IN ACCORDANCE WITH TCA B421.

TOOL ROOM

TOOL ROOM

107A

MEN'S LOCKER

ROOM

MEN'S LATRINE

STAIR HALL

105A

MEN'S

LATRINE/LOCKER

HALL

106A

UTILITY ROOM

107C

MEN'S SHOWER

107B

IT STORAGE

101D

REFER TO FINISH SCHEDULE

FOR FLOORING FINISH

EXISTING TERRAZZO

EF-1

EPOXY FLOORING

RF-1

RESILIENT FLOORING

CS-1

SEALED CONCRETE

FINISH LEGEND

NEW MATERIALS; ALL OTHER FLOOR FINISHES TO REMAIN

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

KEY PLAN

W D

S -1

-D

-0

/2

/2

:0

:4

P

M

A-711

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

G R

O U

N D

F L O

O R

S

IG

N A

G E

A N

D F

IN

IS

H P

L A

N

SCALE: 1/8" = 1'-0"E1

GROUND FLOOR FINISH PLAN AREA - A

0 4' 8' 16'

SCALE: 1/8" = 1'-0"A1

GROUND FLOOR FINISH PLAN AREA - B

0 4' 8' 16'

N N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

GENERAL NOTES:

1. REFER TO ROOM FINISH SCHEDULE AND FINISH LEGEND

FOR FLOOR FINISHES NOT INDICATED ON DRAWING.

2. REFER TO SHEET A-562 FOR FLOOR TRANSITION DETAILS.

3. FOR FLOORING MATERIAL TRANSITIONS WHICH OCCUR AT

DOORWAYS,TERMINATE FINISH TRANSITION AND

TRANSITION STRIP UNDER THE DOOR STOP OR CENTER

UNDER THE CLOSED DOOR.

4. CENTER ALL WALL TILE SO THAT PERIMETER CUTS ARE

EQUAL UNLESS NOTED OTHERWISE.

5. INSTALL WALL TILE IN ACCORDANCE WITH TCA W245 AND

SHOWER RECEPTOR IN ACCORDANCE WITH TCA B421.

MEN'S LATRINE

J.C.

202A

CONFERENCE

203A

OFFICE

203B

OPEN OFFICE

OFFICE

203C

OFFICE

201C

CONFERENCE

201D

OPEN OFFICE

OFFICE

201B

ADMIN

201A

MOTHER'S ROOM

200B

WOMEN'S LATRINE

200A

STAIR ENTRY

VESTIBULE

201E

MID LEVEL ENTRY

VESTIBULE

109A

MID LEVEL STAIR

HALL

109B

REFER TO FINISH SCHEDULE

FOR FLOORING FINISH

EXISTING TERRAZZO

EF-1

EPOXY FLOORING

RF-1

RESILIENT FLOORING

CS-1

SEALED CONCRETE

FINISH LEGEND

NEW MATERIALS; ALL OTHER FLOOR FINISHES TO REMAIN

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

KEY PLAN

W D

S -1

-D

-0

/2

/2

:0

:4

P

M

A-713

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

S E

C O

N D

F L O

O R

S

IG

N A

G E

A N

D F

IN

IS

H P

L A

N

SCALE: 1/8" = 1'-0"E1

SECOND FLOOR FINISH PLAN AREA - A

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR FINISH PLAN AREA - B

0 4' 8' 16'

0 4' 8' 16'

N N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

D

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

W D

S -1

-D

-0

/2

/2

:4

:5

P

M

F-001

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

L

IF

E S

A F

E T

Y C

O D

E A

N D

C R

IT

E

R

IA

1. APPLICABLE CODES AND STANDARDS

ABBREVIATIONS TITLE EDITION

IBC INTERNATIONAL BUILDING CODE 2018

IFC INTERNATIONAL FIRE CODE 2018

IMC INTERNATIONAL MECHANICAL CODE 2018

IEBC INTERNATIONAL EXISTING BUILDING CODE 2018

IPC INTERNATIONAL PLUMBING CODE 2018

NFPA 01 UNIFORM FIRE CODE 2018

NFPA 70 NATIONAL ELECTRICAL CODE 2017

NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2019

NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2019

ABA ARCHITECTURAL BARRIERS ACT 2008

NFPA 101 LIFE SAFETY CODE 2018

UFC 1-200-01 DOD BUILDING CODE 2019

UFC 1-200-02 HIGH PERFOMANCE AND SUSTAINABLE BUILDING REQUIREMENTS 2019

UFC 3-101-01 ARCHITECTURE AND INTERIORS 2019

UFC 3-110-03 ROOFING 2020

UFC 3-600-01 DESIGN: FIRE PROTECTION ENGINEERING FOR FACILITIES 2020

UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS 2018

UFC 4-021-01 DESIGN AND O&M: MASS NOTIFICATION SYSTEMS 2010

2. TYPE OF CONSTRUCTION (IBC TABLE 601)

BUILDING ELEMENT

TYPE OF

CONSTRUCTION

FIRE RESISTANCE

RATING

PRIMARY STRUCTURE FRAME IIB 0 HR

BEARING EXTERIOR WALL IIB 0 HR

BEARING INTERIOR WALL IIB 0 HR *

NON-BEARING EXTERIOR WALL IIB 0 HR

NON-BEARING INTERIOR WALL IIB 0 HR *

FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS AND

JOISTS

IIB 0 HR *

ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS IIB 0 HR

3. CLASSIFICATION OF OCCUPANCY

AREAS IBC NFPA 101

OPEN OFFICE, CIRCULATION, RESTROOMS,

LOBBY, BREAKROOM

BUSINESS, GROUP B (304.1) BUSINESS (6.11.1)

FACTORY AREA FACTORY, GROUP F (306.1) INDUSTRIAL (6.12.1)

STORAGE AREA STORAG, GROUP S2 (311.3) STORAGE (6.1.13.1)

11. MINIMUM EXITS OR EXIT ACCESSES FROM A SPACE OR AREA (IBC 1006.2)

FLOOR / OCCUPANCY

OCCUPANT LOAD PERMITTING ONE

EXIT

OCCUPANT LOAD REQUIRING TWO

EXITS

LEVEL 1 /B, F-2 49 OR LESS 50 OR GREATER

LEVEL 2/B 49 OR LESS 50 OR GREATER

LEVEL 1/S-2 29 OR LESS 30 OR GREATER

15. MINIMUM INTERIOR FINISH RATINGS (NFPA 101, TABLE A.10.2.2)

OCCUPANCY EXITS

EXIT ACCESS

CORRIDORS OTHER SPACES

B CLASS A CLASS B CLASS C

F CLASS B CLASS C CLASS C

S CLASS B CLASS B CLASS C

*EXCEPT AS REQUIRED FOR PASSIVE FIRE PROTECTION. SEE BELOW

13. MINIMUM EGRESS WIDTHS

COMPONENT REQUIREMENT WIDTH (IN) NFPA 101

DOORS IN EGRESS ACCESS PER COMPONENT 32 SECTION 7.2.1.2.3.2

CORRIDOR SERVING 50 OR MORE OCCUPANTS MINIMUM 44 SECTION 38.2.3.2

CORRIDOR SERVING LESS THAN 50 OCCUPANTS MINIMUM 36 SECTION 7.3.4.1

EXISTING STAIR IN EGRESS ACCESS MINIMUM 36 SECTION 7.2.2.2.1.1

OTHER EGRESS COMPONENTS PER PERSON 0.2 TABLE 7.3.3.1

STAIRWAYS PER PERSON 0.3 TABLE 7.3.3.1

8. BUILDING SEPARATION (IBC TABLE 602)

OCCUPANCY ELEVATION

RESTRICTIVE FIRE

SEPARATION DISTANCE

(FT)*

FIRE RESISTIVE RATING

OF EXTERIOR WALL

B, S-2 NORTH/SOUTH/WEST/EAST 10 < X < 30 NO RATING

OL = OCCUPANT LOAD

19. FIRE SUPPRESSION REQUIREMENTS (UFC 3-600-01 4-2.2, 4-9)

SPRINKLERS (IBC 903) STANDPIPE (IBC 905) FIRE EXTINGUISHERS (IBC 906)

*NOT PROVIDED NOT APPLICABLE TO PROJECT SCOPE FIRE EXTINGUISHERS PROVIDED

THROUGHOUT

12. COMMON PATH, DEAD-END, AND TRAVEL DISTANCE LIMITS

OCCUPANCY

COMMON PATH LIMIT (NFPA

101) (FT)

DEAD END LIMIT (NFPA 101)

(FT)

TRAVEL DISTANCE LIMIT

(NFPA 101) (FT)*

B 75 20 300 (300)

F-2 50 50 300 (250)

S-2 50 50 300 (400)

12. OCCUPANT LOAD CALCULATIONS (NFPA 101)

FLOOR AREA FUNCTION OF SPACE AREA (SF)

OCCUPANT

LOAD

FACTOR

(SF/PER

PERSON) OCCUPANTS

LEVEL 1 OFFICES, RESTROOM BUSINESS AREAS 1,425 150 10

LEVEL 2 CONFERENCE ROOMS BUSINESS AREAS 578 15 39

LEVEL 1 MECHANICAL/ELECTRICAL

ROOM

FACTORY/INDUSTRIAL

AREA

62 500 1

LEVEL 1 IT/EQUIPEMENT ROOM FACTORY/INDUSTRIAL

AREA

324 300 2

LEVEL 1/2 LOBBY BUSINESS AREA 277 15 19

LEVEL 1 MENS LOCKER ROOM FACTORY/INDUSTRIAL

AREA

513 - 70

LEVEL 2 LOBBY BUSINESS AREA 472 15 32

LEVEL 1 WOMEN'S LOCKER ROOM FACTORY/INDUSTRIAL

AREA

468 - 15

LEVEL 1 CIRCULATION, RESTROOMS,

BREAKROOM

FACTORY/INDUSTRIAL

AREA

2,916 100 30

LEVEL 2 OPEN OFFICE, CIRCULATION,

RESTROOMS

BUSINESS AREAS 7,378 150 50

LEVEL 1 FACTORY FLOOR FACTORY/INDUSTRIAL

AREA

84,479 100 845

LEVEL 1 STORAGE AREA STORAGE AREA 2,800 300 10

20. FIRE ALARM REQUIREMENTS (UFC 3-600-01 5-1)

MANUAL INITIATION AUTOMATIC INITIATION OCCUPANT NOTIFICATION

MANUAL FIRE ALARM PULL

STATIONS PROVIDED AT EXITS

FLOW AND TAMPER SWITCHES, SPOT

SMOKE DETECTORS AT ALARM

PANELS AND DUCT SMOKE

DETECTORS PROVIDED

VOICE MESSAGING, WHITE FIRE

ALARM AND AMBER MASS

NOTIFICATION STROBES

21. FIRE EXTINGUISHER DISTRIBUTION (NFPA 10)

OCCUPANCY

PRIMARY

CLASSFICATION OF FIRE

AND HAZARD MINIMUM RATING

MINIMUM FLOOR

AREA PER A (SF)

MAX TRAVEL

DISTANCE (FT)

ALL CLASS A:B:C - ORDINARY 2-A 1,500 75

22. SMOKE MANAGEMENT SYSTEMS

SMOKE CONTROL SYSTEM (IBC

909)

SMOKE AND HEAT VENTS (IBC

910) PASSIVE SMOKE MANAGEMENT

NOT REQUIRED NOT REQUIRED SMOKE PARTITIONS WHERE NOTED

* THE REQUIREMENTS OF TABLE 22, SMOKE MANAGEMENT, ARE NOT APPLICABLE TO THE AREAS OF RENOVATION.

* EXISTING BUILDING IS NOT SPRINKLERED AND THE SCOPE OF THE PROJECT WILL NOT CHANGE THE OCCUPANCY CLASSIFICATION OR OCCUPANT LOAD. EXISTING FIRE BARRIERS WILL BE MAINTAINED. IT SHOULD BE NOTED THAT THE GOVERNMENT IS PLANNING A

SEPARATE PROJECT TO ADD FIRE SPRINKLERS TO THIS FACILITY.

TOTAL OCCUPANTS = 1,123

* REFER TO LIFE SAFETY PLANS DOOR TAGS FOR MAXIMUM EGRESS COMPONENT CAPACITY

*THESE VALUES ARE BASED ON THE EXISTING WVA B20 REGULATORY PLANS AFTER THE FIRE SPRINKLER SYSTEM IS

INSTALLED (SEPARATE PROJECT) THE VALUES WILL BE SHOWN IN THE PARENTHESES ()

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

PHASE 2 SCOPE OF WORK:

RENOVATE 115,000 SF MANUFACTURING SHOP AT WATERVLIET ARSENAL. THE EXISTING FACILITY CONSISTS OF A 2 STORY STEEL AND MASONRY OFFICE AREA ATTACHED TO A SINGLE STORY HIGH BAY MANUFACTURING SHOP. THE ENTIRE BUILDING IS CONSIDERED TYPE IIB CONSTRUCTION AND IS UNSPRINKLERED. THERE ARE NO CHANGES TO THE EXISTING OCCUPANCY

CLASSIFICATIONS, OCCUPANT LOAD, EGRESS PATHWAYS, OR FIRE RATED CONSTRUCTION.

BASE BID:

· RENOVATE FIRST FLOOR MEN’S AND WOMEN’S BATHROOMS IN THEIR ENTIRETY COMPLIANT WITH ABA ACCESSIBILITY

· RENOVATE FIRST FLOOR MEN’S AND WOMEN’S CHANGING/LOCKER ROOMS

· RENOVATE/REPLACE FIRST FLOOR PLUMBING FIXTURES IN BATHROOMS (SINKS, FAUCETS, MIRRORS, WATER CLOSETS, VANITIES AND STALLS), REPLACE FIXTURES IN BREAK AND CONFERENCE ROOMS

· REPLACE EXISTING EXTERIOR WINDOWS AT ADMINISTRATIVE OFFICES

· RENOVATE FIRST FLOOR OFFICES, BREAK AND CONFERENCE ROOMS (REPLACE CEILING AND FLOOR TILES, REPLACE

FLOORING)

· RENOVATE HVAC ON FIRST FLOOR (HEATING SYSTEM IN OFFICES, BATHROOMS AND LOCKER ROOMS)

· RENOVATE ENTRYWAY AND STAIRS ON WEST SIDE OF BUILDING

· REPLACE FIRST FLOOR DOORS TO BATHROOMS AND LOCKER ROOMS

· RENOVATE FIRST FLOOR SHOP/MANUFACTURING AREA (PAINT ENTIRE WALLS AND COLUMNS TO 8’-0” HEIGHT)

· RENOVATE SECOND FLOOR MEN’S AND WOMEN’S BATHROOMS (SINKS, FAUCETS, MIRRORS, WATER CLOSETS, VANITIES, STALLS, PAINT WALLS, REPLACE CEILING AND FLOOR TILES), RENOVATE TO BE COMPLIANT WITH ABA ACCESSIBILITY

· CREATE LACTATION ROOMS ON THE FIRST AND SECOND FLOORS

· ABATE FIRST AND SECOND FLOOR ADMINISTRATIVE AND BATHROOM SPACES FOR ACM

· REPLACE EXTERIOR ARCHITECTURAL ITEMS (WINDOWS, INSULATED WALL PANELS, AND DOORS AT SHOP AREA)

· REPLACE PEDESTRIAN ACCESS BRIDGE, INCLUDE NEW CANOPY

· INTERIOR/EXTERIOR MASONRY REPAIRS

· RECAPITALIZATION SCOPE OF ENTIRE FACILITY AS OUTLINED IN THE SOW DOCUMENT, REVISION 05, DATED 3 FEBRUARY

2022, EXCEPT FOR OPTIONS LISTED BELOW.

OPTIONS:

ARCHITECTURAL –

· PAINT ALL EXPOSED STEEL COLUMNS THROUGHOUT SHOP/MANUFACTURING AREA FULL HEIGHT FROM TOP OF EXISTING "TAN" LINE TO UNDERSIDE OF EXISTING ROOF DECK. INCLUDE ELEVATED PORTION OF MASONRY WALL JUST BELOW THE ROOF

DECK (APPROXIMATELY 6'-0" HIGH) AROUND ENTIRE INTERIOR PERIMETER OF SHOP.

· INSTALL TRANSLUCENT FIBERGLASS PANELS IN LIEU OF INSULATED METAL WALL PANELS FOR THE EXTERIOR WALLS.

· INSTALL TRANSLUCENT FIBERGLASS PANELS IN LIEU OF INSULATED METAL WALL PANELS FOR THE EXISTING SKYLIGHTS.

· INSTALL EXTERIOR ENTRY CANOPY AT WEST MAIN ENTRANCE TO BUILDING

· REPAINT THE EXISTING EXTERIOR EXIT STAIR ON THE WEST SIDE. ADD EMERGENCY LIGHTING.

· REPAINT THE EGRESS PATHWAYS/FLOOR STRIPING THROUGHOUT THE SHOP/MANUFACTURING AREA.

ELECTRICAL –

· DISCONNECT AND REMOVE TWO EXISTING 100A MCB, 125/250V, 1 PHASE, 3 WIRE, 20 POLE, RECESSED

PANELBOARDS LABELLED M3 AND M4 ON THE GROUND FLOOR.

· PROVIDE 120V, 1 PHASE BRANCH CIRCUITING, FOR PLUMBING FIXTURE AUTOMATIC/HANDS FREE CONTROLS, FROM

NEAREST RECEPTACLE PANELBOARD.

· ELECTRICAL UPGRADES WITHIN THE MANUFACTURING FLOOR ASSOCIATED WITH RECAPITALIZATION SCOPE.

MECHANICAL –

· MANUFACTURING FLOOR COOLING

UP

UP

UP

DN

CP

401' - 7 1/2"

107A

105A

104C

104B104A

101101A

100B

84,683 SF

SHOP /

MANUFACTURING

AREA

100E

100C

107C

107B

101D

101B1

101A6

101C1101A3

101A1

100D1

100A4

109D

104D

103A

101C

101B

104E

106A

139'CP:0'

158'CP:0' 235'CP:0' 218'CP:0'

175'CP:0' 175'CP:0'

F-2, LOW-HAZARD, FACTORY INDUSTRIAL

34" 32"

34" 32"

34" 32"

34" 32"

34" 32"

34" 32"

* PROVIDED FOR REFERENCE ONLY - BASED ON WVA B20 REGULATORY PLANS

EXISTING 3 HR FIRE BARRIER

CONTRACTOR TO MARK WITH

IDENTIFICATION PER IBC (703.7)

NUMBER OF OCCUPANTS

ROOM NAME

AREA

CLEAR WIDTH

EXIT CAPACITY

OCCUPANTS SERVED

COMMON PATH OF

TRAVEL

TRAVEL

DISTANCE

EGRESS

PATH

COMMON PATH

TERMINATION POINT

EXIT DOOR

REQUIRED WIDTH

36"

22"

44" 44"

NAME

XX

111SF

GENERAL NOTES

REFER TO ARCHITECTURAL LEGEND FOR ADDITIONAL

INFORMATION REGARDING SYMBOLS AND ABBREVIATIONS.

REFER TO F-001 FOR LIFE SAFETY NARRATIVE AND

BUILDING CODE ANALYSIS.

REFER TO THE ELECTRICAL LIGHTING PLANS FOR LOCATION

OF EXIT SIGNS AND EMERGENCY LIGHTING.

REFER TO THE FIRE SUPPRESSION AND ALARM PLANS FOR

LOCATION OF FIRE PROTECTION DEVICES.

FINAL LOCATIONS OF FIRE EXTINGUISHERS

SHALL BE APPROVED BY THE AHJ PRIOR TO INSTALLATION.

DOOR EGRESS TAG

FIRE AND SMOKE RESISTIVE CONSTRUCTION

STAIR EGRESS TAG

ROOM OCCUPANCY TAG

EGRESS PATH

TERMINATION OF

DEAD END

CORRIDOR

DEAD END DISTANCE

DEAD END CORRIDOR

100'

100'CP:66'

A:B:C: TYPE DRY CHEMICAL

4A-20B-C

PORTABLE FIRE EXTINGUISHERS AND HOSE REELS

FE:SR

EXTINGUISHER TYPE

EXTINGUISHER MOUNTING

1.

2.

3.

4.

5.

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

W D

S -1

-D

-0

/2

/2

:0

:3

P

M

F-002

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

O V

E R

A L L G

R O

U N

D F

L O

O R

L

IF

E S

A F

E T

Y P

L A

N

SCALE: 3/64" = 1'-0"B1

OVERALL GROUND FLOOR LIFE SAFETY PLAN N

0 16' 32' 48'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

CP

EXISTING 3 HR FIRE BARRIER

CONTRACTOR TO MARK WITH

IDENTIFICATION PER IBC (703.7)

NUMBER OF OCCUPANTS

ROOM NAME

AREA

CLEAR WIDTH

EXIT CAPACITY

OCCUPANTS SERVED

COMMON PATH OF

TRAVEL

TRAVEL

DISTANCE

EGRESS

PATH

COMMON PATH

TERMINATION POINT

EXIT DOOR

REQUIRED WIDTH

36"

22"

44" 44"

NAME

XX

111SF

GENERAL NOTES

REFER TO ARCHITECTURAL LEGEND FOR ADDITIONAL

INFORMATION REGARDING SYMBOLS AND ABBREVIATIONS.

REFER TO F-001 FOR LIFE SAFETY NARRATIVE AND

BUILDING CODE ANALYSIS.

REFER TO THE ELECTRICAL LIGHTING PLANS FOR LOCATION

OF EXIT SIGNS AND EMERGENCY LIGHTING.

REFER TO THE FIRE SUPPRESSION AND ALARM PLANS FOR

LOCATION OF FIRE PROTECTION DEVICES.

FINAL LOCATIONS OF FIRE EXTINGUISHERS

SHALL BE APPROVED BY THE AHJ PRIOR TO INSTALLATION.

DOOR EGRESS TAG

FIRE AND SMOKE RESISTIVE CONSTRUCTION

STAIR EGRESS TAG

ROOM OCCUPANCY TAG

EGRESS PATH

TERMINATION OF

DEAD END

CORRIDOR

DEAD END DISTANCE

DEAD END CORRIDOR

100'

100'CP:66'

A:B:C: TYPE DRY CHEMICAL

4A-20B-C

PORTABLE FIRE EXTINGUISHERS AND HOSE REELS

FE:SR

EXTINGUISHER TYPE

EXTINGUISHER MOUNTING

1.

2.

3.

4.

5.

A

10c

10b

10a

Aa B Ba C Ca Cb Da Db E Ea F Fa G

1,503 SF

TOOL ROOM

551 SF

TOOL ROOM

MEN'S LOCKER

ROOM

446 SF

MEN'S

LATRINE

467 SF

WOMEN'S

LOCKER

ROOM

288 SF

WOMEN'S

LATRINE

149 SF

WOMEN'S

LOCKER

HALL

296 SF

STAIR HALL

121 SF

WOMEN'S

LATRINE

HALL

1,069 SF

BREAK

ROOM

739 SF

SUPERVISOR'S

OFFICE

261 SF

OFFICE

338 SF

OFFICE

43 SF

WOMEN'S

SHOWER

62 SF

UTILITY

ROOM

302 SF

BREAK

ROOM HALL

87 SF

ALL

GENDER

112 SF

MEN'S

LATRINE/LOCKER

HALL35 SF

HALL

MEN'S SHOWER

30 SF

J.C.

322 SF

IT STORAGE

55 SF

MOTHER'S

ROOM

FE:SR

FE:SR

FE:SR

137'CP:45'

C P

:3

B, BUSNINESS

S-2, LOW-HAZARD STORAGE

F-2, LOW-HAZARD, FACTORY INDUSTRIAL

2 2

35 SF

1 1

513 SF

2 8

33.5"

33.5"

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

KEY PLAN

W D

S -1

-D

-0

/2

/2

:0

:3

P

M

F-010

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

G R

O U

N D

F L O

O R

L

IF

E S

A F

E T

Y P

L A

N

SCALE IN FEET

0 8' 16' 24'

SCALE: 3/32" = 1'-0"E1

GROUND FLOOR ENLARGED LIFE SAFETY PLAN

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y

CP

EXISTING 3 HR FIRE BARRIER

CONTRACTOR TO MARK WITH

IDENTIFICATION PER IBC (703.7)

NUMBER OF OCCUPANTS

ROOM NAME

AREA

CLEAR WIDTH

EXIT CAPACITY

OCCUPANTS SERVED

COMMON PATH OF

TRAVEL

TRAVEL

DISTANCE

EGRESS

PATH

COMMON PATH

TERMINATION POINT

EXIT DOOR

REQUIRED WIDTH

36"

22"

44" 44"

NAME

XX

111SF

GENERAL NOTES

REFER TO ARCHITECTURAL LEGEND FOR ADDITIONAL

INFORMATION REGARDING SYMBOLS AND ABBREVIATIONS.

REFER TO F-001 FOR LIFE SAFETY NARRATIVE AND

BUILDING CODE ANALYSIS.

REFER TO THE ELECTRICAL LIGHTING PLANS FOR LOCATION

OF EXIT SIGNS AND EMERGENCY LIGHTING.

REFER TO THE FIRE SUPPRESSION AND ALARM PLANS FOR

LOCATION OF FIRE PROTECTION DEVICES.

FINAL LOCATIONS OF FIRE EXTINGUISHERS

SHALL BE APPROVED BY THE AHJ PRIOR TO INSTALLATION.

DOOR EGRESS TAG

FIRE AND SMOKE RESISTIVE CONSTRUCTION

STAIR EGRESS TAG

ROOM OCCUPANCY TAG

EGRESS PATH

TERMINATION OF

DEAD END

CORRIDOR

DEAD END DISTANCE

DEAD END CORRIDOR

100'

100'CP:66'

A:B:C: TYPE DRY CHEMICAL

4A-20B-C

PORTABLE FIRE EXTINGUISHERS AND HOSE REELS

FE:SR

EXTINGUISHER TYPE

EXTINGUISHER MOUNTING

1.

2.

3.

4.

5.

A

10c

10b

10a

Aa B Ba C Ca Cb Da Db E Ea F Fa G

2,722 SF

OPEN

OFFICE

280 SF

CONFERENCE

183 SF

OFFICE

54 SF

VESTIBULE

211 SF

OFFICE

143 SF

ADMIN

208 SF

OFFICE

298 SF

CONFERENCE

263 SF

MEN'S

LATRINE

STAIR ENTRY

3,036 SF

OPEN

OFFICE

239 SF

OFFICE

77 SF

MOTHER'S

ROOM

158 SF

WOMEN'S

LATRINE

59 SF

PASSAGE

20 SF

J.C.

FE:SR

FE:SR

FE:SR

FE:SR FE:SR

B-BUSINESS

B-BUSINESS

C P

:0

83'CP:10'

1 1

33.5" 32"

472 SF

32"

33.5"

33.5" 32"

130 SF

MID LEVEL

ENTRY

VESTIBULE

MID LEVEL STAIR

HALL

DN DN

147 SF

32"

33.5"

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C O

N T

R A

C T

N O

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

SHEET ID

2 864 10

E

F

G

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

A N

D R

E P

A

IR

W A

T E

R V

L

IE

T A

R S

E N

A L

N E

W Y

O R

K U

S A

C E

W

A T

E R

V L

IE

T

N E

W Y

O R

K

A S

I N

D

IC

A T

E D

US Army Corps of Engineers ®

P N

O

NOT FOR CONSTRUCTION

PHASE 2 RECAPITALIZATION

100% FINAL DESIGN

KEY PLAN

W D

S -1

-D

-0

/2

/2

:0

:4

P

M

F-011

B .B

A K

A S

C .R

E E

D

R .A

L F

A O

U R

I

J U

L Y

P ro j.

N o .1

S E

C O

N D

F L O

O R

L

IF

E S

A F

E T

Y P

L A

N

SCALE: 3/32" = 1'-0"E1

SECOND FLOOR ENLARGED LIFE SAFETY PLAN

0 8' 16' 24'

N

SCALE: 1/8" = 1'-0"C1

ENLARGED ENTRY LIFE SAFETY PLAN

0 4' 8' 16'

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

F

IN

A L D

E S

IG

N

I S

S U

E F

O R

B

ID

J U

L Y